Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONVENTIONAL RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Investigations of nanodimensional Al{sup 2}O{sup 3} films deposited by ion-plasma sputtering onto porous silicon

The purpose of this study is the deposition of nanodimensional Al{sup 2}O{sup 3} films on the surface of nanoporous silicon and also fundamental investigations of the structural, optical, and morphological properties of these materials. Analyzing the results obtained here, it is possible to state that ultrathin nanostructured Al{sup 2}O{sup 3} films can be obtained in the form of threads oriented in one direction and located at a distance of 300–500 nm from each other using ion-plasma sputtering on a layer of porous silicon. Such a mechanism of aluminum-oxide growth is conditioned by the crystallographic orientation of the initial single-crystalline silicon wafer used to fabricate the porous layer. The results of optical spectroscopy show that the Al{sup 2}O{sup 3}/por-Si/Si(111) heterophase structure perfectly transmits electromagnetic radiation in the range of 190–900 nm. The maximum in the dispersion of the refractive index obtained for the Al{sup 2}O{sup 3} film grown on por-Si coincides with the optical-absorption edge for aluminum oxide and is located in the region of ∼5.60 eV. This fact is confirmed by the results of calculations of the optical-absorption spectrum of the Al{sup 2}O{sup 3}/por-Si/Si(lll) heterophase structure. The Al{sup 2}O{sup 3} films formed on the heterophase-structure surface in the form of nanodimensional structured threads can serve as channels of optical conduction and can be rather efficiently introduced into conventional technologies, which are of great importance in microelectronics and optoelectronics.

36 MATERIALS SCIENCE↗

SU-F-R-52: A Comparison of the Performance of Radiomic Features From Free Breathing and 4DCT Scans in Predicting Disease Recurrence in Lung Cancer SBRT Patients

Purpose: There is a clinical need to identify patients who are at highest risk of recurrence after being treated with stereotactic body radiation therapy (SBRT). Radiomics offers a non-invasive approach by extracting quantitative features from medical images based on tumor phenotype that is predictive of an outcome. Lung cancer patients treated with SBRT routinely undergo free breathing (FB image) and 4DCT (average intensity projection (AIP) image) scans for treatment planning to account for organ motion. The aim of the current study is to evaluate and compare the prognostic performance of radiomic features extracted from FB and AIP images in lung cancer patients treated with SBRT to identify which image type would generate an optimal predictive model for recurrence. Methods: FB and AIP images of 113 Stage I-II NSCLC patients treated with SBRT were analysed. The prognostic performance of radiomic features for distant metastasis (DM) was evaluated by their concordance index (CI). Radiomic features were compared with conventional imaging metrics (e.g. diameter). All p-values were corrected for multiple testing using the false discovery rate. Results: All patients received SBRT and 20.4% of patients developed DM. From each image type (FB or AIP), nineteen radiomic features were selected based on stability and variance. Both image types had five common and fourteen different radiomic features. One FB (CI=0.70) and five AIP (CI range=0.65–0.68) radiomic features were significantly prognostic for DM (p<0.05). None of the conventional features derived from FB images (range CI=0.60–0.61) were significant but all AIP conventional features were (range CI=0.64–0.66). Conclusion: Features extracted from different types of CT scans have varying prognostic performances. AIP images contain more prognostic radiomic features for DM than FB images. These methods can provide personalized medicine approaches at low cost, as FB and AIP data are readily available within a large number of radiation oncology departments. R.M. had consulting interest with Amgen (ended in 2015).

60 APPLIED LIFE SCIENCES↗

X-ray phase contrast imaging of biological specimens with femtosecond pulses of betatron radiation from a compact laser plasma wakefield accelerator

We show that x-rays from a recently demonstrated table top source of bright, ultrafast, coherent synchrotron radiation [Kneip et al., Nat. Phys. 6, 980 (2010)] can be applied to phase contrast imaging of biological specimens. Our scheme is based on focusing a high power short pulse laser in a tenuous gas jet, setting up a plasma wakefield accelerator that accelerates and wiggles electrons analogously to a conventional synchrotron, but on the centimeter rather than tens of meter scale. We use the scheme to record absorption and phase contrast images of a tetra fish, damselfly and yellow jacket, in particular highlighting the contrast enhancement achievable with the simple propagation technique of phase contrast imaging. Coherence and ultrafast pulse duration will allow for the study of various aspects of biomechanics.

43 PARTICLE ACCELERATORS↗

Dosimetric impact of image artifact from a wide-bore CT scanner in radiotherapy treatment planning

Purpose: Traditional computed tomography (CT) units provide a maximum scan field-of-view (sFOV) diameter of 50 cm and a limited bore size, which cannot accommodate a large patient habitus or an extended simulation setup in radiation therapy (RT). Wide-bore CT scanners with increased bore size were developed to address these needs. Some scanners have the capacity to reconstruct the CT images at an extended FOV (eFOV), through data interpolation or extrapolation, using projection data acquired with a conventional sFOV. Objects that extend past the sFOV for eFOV reconstruction may generate image artifacts resulting from truncated projection data; this may distort CT numbers and structure contours in the region beyond the sFOV. The purpose of this study was to evaluate the dosimetric impact of image artifacts from eFOV reconstruction with a wide-bore CT scanner in radiotherapy (RT) treatment planning. Methods: Testing phantoms (i.e., a mini CT phantom with equivalent tissue inserts, a set of CT normal phantoms and anthropomorphic phantoms of the thorax and the pelvis) were used to evaluate eFOV artifacts. Reference baseline images of these phantoms were acquired with the phantom centrally positioned within the sFOV. For comparison, the phantoms were then shifted laterally and scanned partially outside the sFOV, but still within the eFOV. Treatment plans were generated for the thoracic and pelvic anthropomorphic phantoms utilizing the Eclipse treatment planning system (TPS) to study the potential effects of eFOV artifacts on dose calculations. All dose calculations of baseline and test treatment plans were carried out using the same MU. Results: Results show that both body contour and CT numbers are altered by image artifacts in eFOV reconstruction. CT number distortions of up to -356 HU for bone tissue and up to 323 HU for lung tissue were observed in the mini CT phantom. Results from the large body normal phantom, which is close to a clinical patient size, show average CT number changes of up to -49 HU. Wider distribution (i.e., standard deviation) of the HU values was seen when the phantom was placed at more than 2.8 cm beyond the 50 cm sFOV. Anthropomorphic phantom studies with several standard beam configurations show that body contour distortion causes tumor dose calculation reduction of 3.0 and 1.9% for 6 and 23 MV x-rays, respectively, when not accounting for tissue heterogeneities during dose computation. When heterogeneity correction is used in planning, the competing effects of the body contour distortion and the CT number distortion cause a smaller error in tumor dose calculation. Less than 0.9% error in calculated dose was observed in volumetric modulated arc therapy (VMAT) treatment plans. Conclusions: The image artifacts from eFOV reconstruction alter the CT numbers and body contours of the imaged objects, which has the potential to produce inaccuracies in dose calculations during radiotherapy treatment planning. The radiation therapy team should be aware of these image artifacts and their effects on target dose calculations during CT simulation as well as treatment planning.

61 RADIATION PROTECTION AND DOSIMETRY↗

Bottom-up reconstruction scenarios for (un)constrained MSSM parameters at the CERN LHC

We consider some specific inverse problem or 'bottom-up' reconstruction strategies at the CERN LHC for both general and constrained minimal supersymmetric standard model (MSSM) parameters, starting from a plausibly limited set of sparticle identification and mass measurements, using mainly gluino/squark cascade decays, plus eventually the lightest Higgs boson mass. For the three naturally separated sectors of gaugino/Higgsino, squark/slepton, and Higgs parameters, we examine different step-by-step algorithms based on rather simple, entirely analytical, inverted relations between masses and basic MSSM parameters. This includes also reasonably good approximations of some of the relevant radiative correction calculations. We distinguish the constraints obtained for a general MSSM from those obtained with universality assumptions in the three different sectors. Our results are compared at different stages with the determination from more standard 'top-down' fit of models to data, and finally combined into a global determination of all the relevant parameters. Our approach gives complementary information to more conventional analysis, and is not restricted to the specific LHC measurement specificities. In addition, the bottom-up renormalization group evolution of general MSSM parameters, being an important ingredient in this framework, is illustrated as a new publicly available option of the MSSM spectrum calculation code SuSpect.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Countdown to perovskite space launch: Guidelines to performing relevant radiation-hardness experiments

Perovskite photovoltaics (PVs) are under intensive development for promise in terrestrial energy production. Soon, the community will find out how much of that promise may become reality. Perovskites also open new opportunities for lower cost space power. However, radiation tolerance of space environments requires appropriate analysis of relevant devices irradiated under representative radiation conditions. We present guidelines designed to rigorously test the radiation tolerance of perovskite PVs. We review radiation conditions in common orbits, calculate nonionizing and ionizing energy losses (NIEL and IEL) for perovskites, and prioritize proton radiation for effective nuclear interactions. Low-energy protons (0.05-0.15 MeV) create a representative uniform damage profile, whereas higher energy protons (commonly used in ground-based evaluation) require significantly higher fluence to accumulate the equivalent displacement damage dose due to lower scattering probability. Furthermore, high-energy protons may "heal" devices through increased electronic ionization. These procedural guidelines differ from those used to test conventional semiconductors.

14 SOLAR ENERGY↗

Quality Assurance for the Geometric Accuracy of Cone-Beam CT Guidance in Radiation Therapy

The introduction of volumetric X-ray image-guided radiotherapy systems allows improved management of geometric variations in patient setup and internal organ motion. As these systems become a routine clinical modality, we propose a daily quality assurance (QA) program for cone-beam computed tomography (CBCT) integrated with a linear accelerator. The image-guided system used in this work combines a linear accelerator with conventional X-ray tube and an amorphous silicon flat-panel detector mounted orthogonally from the accelerator central beam axis. This article focuses on daily QA protocols germane to geometric accuracy of the CBCT systems and proposes tolerance levels on the basis of more than 3 years of experience with seven CBCT systems used in our clinic. Monthly geometric calibration tests demonstrate the long-term stability of the flex movements, which are reproducible within {+-}0.5 mm (95% confidence interval). The daily QA procedure demonstrates that, for rigid phantoms, the accuracy of the image-guided process can be within 1 mm on average, with a 99% confidence interval of {+-}2 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-95: Predicting Treatment Outcomes for Prostate Cancer: Irradiation Responses of Prostate Cancer Stem Cells

Purpose: Most prostate cancers are slow-growing diseases but normally require much higher doses (80Gy) with conventional fractionation radiotherapy, comparing to other more aggressive cancers. This study is to disclose the radiobiological basis of this discrepancy by proposing the concept of prostate cancer stem cells (CSCs) and examining their specific irradiation responses. Methods: There are overwhelming evidences that CSC may keep their stemness, e.g. the competency of cell differentiation, in hypoxic microenvironments and hence become radiation resistive, though the probability is tiny for aggressiveness cancers. Tumor hypoxia used to be considered as an independent reason for poor treatment outcomes, and recent evidences showed that even prostate cancers were also hypoxic though they are very slow-growing. In addition, to achieve comparable outcomes to other much more aggressive cancers, much higher doses (rather than lower doses) are always needed for prostate cancers, regardless of its non-aggressiveness. All these abnormal facts can only be possibly interpreted by the irradiation responses characteristics of prostate CSCs. Results: Both normal cancer cells (NCCs) and CSCs exiting in tumors, in which NCCs are mainly for symptoms whereas killing all CSCs achieves disease-free. Since prostate cancers are slow-growing, the hypoxia in prostate cancers cannot possibly from NCCs, thus it is caused by hypoxic CSCs. However, single hypoxic cell cannot be imaged due to limitation of imaging techniques, unless a large group of hypoxic cells exist together, thus most of CSCs in prostate cancers are virtually hypoxic, i.e. not in working mode because CSCs in proliferating mode have to be normoxic, and this explains why prostate cancers are unaggressive. Conclusion: The fractional dose in conventional radiotherapy (∼2Gy) could only kill NCCs and CSCs in proliferating modes, whereas most CSCs survived fractional treatments since they were hypoxic, thus to eliminate all CSCs and achieve disease-free, much more fractionations are needed.

60 APPLIED LIFE SCIENCES↗

An improved phase shift reconstruction algorithm of fringe scanning technique for X-ray microscopy

The X-ray phase imaging method has been applied to observe soft biological tissues, and it is possible to image the soft tissues by using the benefit of the so-called “Talbot effect” by an X-ray grating. One type of the X-ray phase imaging method was reported by combining an X-ray imaging microscope equipped by a Fresnel zone plate with a phase grating. Using the fringe scanning technique, a high-precision phase shift image could be obtained by displacing the grating step by step and measuring dozens of sample images. The number of the images was selected to reduce the error caused by the non-sinusoidal component of the Talbot self-image at the imaging plane. A larger number suppressed the error more but increased radiation exposure and required higher mechanical stability of equipment. In this paper, we analyze the approximation error of fringe scanning technique for the X-ray microscopy which uses just one grating and proposes an improved algorithm. We compute the approximation error by iteration and substitute that into the process of reconstruction of phase shift. This procedure will suppress the error even with few sample images. The results of simulation experiments show that the precision of phase shift image reconstructed by the proposed algorithm with 4 sample images is almost the same as that reconstructed by the conventional algorithm with 40 sample images. We also have succeeded in the experiment with real data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dosimetric verification of IMAT delivery with a conventional EPID system and a commercial portal dose image prediction tool

Purpose: The electronic portal imaging device (EPID) is a system for checking the patient setup; as a result of its integration with the linear accelerator and software customized for dosimetry, it is increasingly used for verification of the delivery of fixed-field intensity-modulated radiation therapy (IMRT). In order to extend such an approach to intensity-modulated arc therapy (IMAT), the combined use of an EPID system and a portal dose image prediction (PDIP) tool has been investigated. Methods: The dosimetric behavior of an EPID system, mechanically reinforced to maintain its positional stability during the accelerator gantry rotation, has been studied to assess its ability to measure portal dose distributions for IMAT treatment beams. In addition, the PDIP tool of a commercial treatment planning system, commonly used for static IMRT dosimetry, has been validated for simulating the PDIs of IMAT treatment fields. The method has been applied to the delivery verification of 23 treatment fields that were measured in their dual mode of IMRT and IMAT modalities. Results: The EPID system has proved to be appropriate for measuring the PDIs of IMAT fields; additionally the PDIP tool was able to simulate these accurately. The results are quite similar to those obtained for static IMRT treatment verification, although it was necessary to investigate the dependence of the EPID signal and of the accelerator monitor chamber response on variable dose rate. Conclusions: Our initial tests indicate that the EPID system, together with the PDIP tool, is a suitable device for the verification of IMAT plan delivery; however, additional tests are necessary to confirm these results.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric comparison of 3D conformal, IMRT, and V-MAT techniques for accelerated partial-breast irradiation (APBI)

The purpose is to dosimetrically compare the following 3 delivery techniques: 3-dimensional conformal radiation therapy (3D-CRT), intensity-modulated arc therapy (IMRT), and volumetric-modulated arc therapy (V-MAT) in the treatment of accelerated partial-breast irradiation (APBI). Overall, 16 patients with T1/2N0 breast cancer were treated with 3D-CRT (multiple, noncoplanar photon fields) on the RTOG 0413 partial-breast trial. These cases were subsequently replanned using static gantry IMRT and V-MAT technology to understand dosimetric differences among these 3 techniques. Several dosimetric parameters were used in plan quality evaluation, including dose conformity index (CI) and dose-volume histogram analysis of normal tissue coverage. Quality assurance studies including gamma analysis were performed to compare the measured and calculated dose distributions. The IMRT and V-MAT plans gave more conformal target dose distributions than the 3D-CRT plans (p < 0.05 in CI). The volume of ipsilateral breast receiving 5 and 10 Gy was significantly less using the V-MAT technique than with either 3D-CRT or IMRT (p < 0.05). The maximum lung dose and the ipsilateral lung volume receiving 10 (V{sub 10}) or 20 Gy (V{sub 20}) were significantly less with both V-MAT and IMRT (p < 0.05). The IMRT technique was superior to 3D-CRT and V-MAT of low dose distributions in ipsilateral lung (p < 0.05 in V{sub 5} and D{sub 5}). The total mean monitor units (MUs) for V-MAT (621.0 ± 111.9) were 12.2% less than those for 3D-CRT (707.3 ± 130.9) and 46.5% less than those for IMRT (1161.4 ± 315.6) (p < 0.05). The average machine delivery time was 1.5 ± 0.2 minutes for the V-MAT plans, 7.0 ± 1.6 minutes for the 3D-CRT plans, and 11.5 ± 1.9 minutes for the IMRT plans, demonstrating much less delivery time for V-MAT. Based on this preliminary study, V-MAT and IMRT techniques offer improved dose conformity as compared with 3D-CRT techniques without increasing dose to the ipsilateral lung. In terms of MU and delivery time, V-MAT is significantly more efficient for APBI than for conventional 3D-CRT and static-beam IMRT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Timelike Virtual Compton Scattering from Electron-Positron Radiative Annihilation

We propose measurements of the deeply virtual Compton amplitude (DVCS), gamma* to H H-bar gamma, in the timelike t = (p_{H} + p_{H-bar})^2 > 0 kinematic domain which is accessible at electron-positron colliders via the radiative annihilation process e+ e- to H H-bar gamma. These processes allow the measurement of timelike deeply virtual Compton scattering for a variety of H H-bar hadron pairs such as pi+ pi-, K+ K-, and D D-bar as well as p p-bar. As in the conventional spacelike DVCS, there are interfering coherent amplitudes contributing to the timelike processes involving C= - form factors. The interference between the amplitudes measures the phase of the C=+ timelike DVCS amplitude relative to the phase of the timelike form factors and can be isolated by considering the forward-backward e+ \leftrightarrow e- asymmetry. The J=0 fixed pole contribution which arises from the local coupling of the two photons to the quark current plays a special role. As an example we present a simple

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Uranium mining and norm, a North American perspective - 15545

All soils and rocks contain naturally occurring radioactive materials (NORM). Many ores and raw materials contain relatively elevated levels of natural radionuclides and processing such materials can further increase the concentrations of natural radionuclides, sometimes referred to as technologically enhanced naturally occurring radioactive materials (TENORM). Examples of NORM minerals include uranium ores, monazite (a source of rare earth minerals), and phosphate rock used to produce phosphate fertilizer. Such activities have the potential to result in above background radiation exposure to workers and the public. Following a brief review of the sources and exposure from NORM in these varied industries, this paper will then present an overview of uranium mining and recovery in North America including discussion on the methods currently being used, production of NORM materials and wastes associated with these uranium recovery methods and the radiological composition of the NORM wastes produced by uranium recovery. The paper includes descriptions of the methods and associated NORM produced by both conventional (underground, open pit) and in situ recovery (ISR) mining methods and identifies the responsible government agencies in the US and Canada assigned the authority to regulate and control these NORM materials. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radiation Dose Prescription for Non-Small-Cell Lung Cancer According to Normal Tissue Dose Constraints: An In Silico Clinical Trial

Purpose: Local tumor recurrence remains a major problem in patients with inoperable non-small-cell lung cancer undergoing radiotherapy. We investigated the theoretical gain in the estimated tumor control probability (TCP) using an individualized maximal tolerable dose (MTD) prescription, for both conventional and accelerated fractionation schemes. Methods and Materials: For 64 non-small-cell lung cancer patients, five treatment plans were compared, dependent on the normal tissue dose constraints for the lung and spinal cord. The first two used a classic fractionation (2 Gy/d, 5 d/wk) to a total dose of 60 Gy (QD{sub classic}) or determined by the individualized MTD (QD{sub MTD}). The third scheme assumed a hypofractionated schedule of 2.75-Gy fractions (QD{sub hypofr}). The fourth and fifth assumed hyperfractionation and acceleration (1.8 Gy twice daily, either BID{sub classic} or BID{sub MTD}). The TCPs for the groups of patients were estimated. Results: The mean biologic equivalent dose in 2-Gy fractions for tumor, corrected for accelerated repopulation was significantly greater for the BID{sub MTD} scheme (62.1 Gy) than for any other scheme (QD{sub classic}, 47.5 Gy; QD{sub MTD}, 52.0 Gy; QD{sub hypofr}, 56.9 Gy; and BID{sub classic}, 56.9 Gy; p < 0.001). Although both dose-escalation (QD{sub MTD}) and hypofractionation (QD{sub hypofr}) resulted in an increase in the mean estimated TCP of 5.6% (p < 0.001) and 14.6% (p < 0.001), respectively, compared with QD{sub classic}, the combination of escalation and acceleration (BID{sub MTD}) improved the mean estimated TCP by 26.4% (p < 0.001). Conclusion: The results of this planning study showed a large gain in the estimated TCP using an MTD scheme with 1.8-Gy fractions BID compared with other fractionation schedules. Clinical studies implementing this concept are ongoing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pretargeted Radioimmunotherapy Using Anti-CD45 Monoclonal Antibodies to Deliver Radiation to Murine Hematolymphoid Tissues and Human Myeloid Leukemia

The efficacy of radioimmunotherapy (RIT) for treatment of patients with hematological malignancies frequently fails because of disease recurrence. We therefore conducted pretargeted RIT studies to augment the efficacy in mice of therapy using a pretargeted anti-human (h)CD45 antibody (Ab)-streptavidin (SA) conjugate followed by delivery of a biotinylated clearing agent and radiolabeled-DOTA-biotin. Tumor-to-blood ratios at 24 hours were 20:1 using pretargeted anti-hCD45 RIT and <1:1 with conventional RIT. In vivo imaging studies confirmed that the pretargeted RIT approach provided high-contrast tumor images with minimal blood-pool activity, whereas directly-labeled anti-hCD45 Ab produced distinct tumor images but the blood pool retained a large amount of labeled antibody for a prolonged time. Therapy experiments demonstrated that 90Y-DOTA-biotin significantly prolonged survival of mice treated pretargeted with anti-hCD45 Ab-SA compared to mice treated with conventional RIT using 90Y-labeled anti-hCD45 Ab at the maximally tolerated dose (400 µCi). Since human CD45 antigens are confined to xenograft tumor cells in this model, and all murine tissues are devoid of hCD45 and will not bind anti-hCD45 Ab, we also compared one-step and pretargeted RIT using an anti-murine (m)CD45 Ab (A20 ) in a model where the target antigen is present on normal hematopoietic tissues. After 24 hours, 27.3 ± 2.8% of the injected dose of radionuclide was delivered per gram (% ID/g) of lymph node using 131I-A20-Ab compared with 40.0 ± 5.4% ID/g for pretargeted 111In-DOTA-biotin (p value). These data suggest that multi-step pretargeted methods for delivering RIT are superior to conventional RIT when targeting CD45 for the treatment of leukemia and may allow for the intensification of therapy, while minimizing toxicities.

60 APPLIED LIFE SCIENCES↗

Organ Preservation With Concurrent Chemoradiation for Advanced Laryngeal Cancer: Are We Succeeding?

Purpose: To determine the rates of organ preservation and function in patients with advanced laryngeal and hypopharyngeal carcinomas treated with concurrent chemoradiotherapy (CRT). Methods and Materials: Between April 1999 and September 2005, 82 patients with advanced laryngeal (67%) and hypopharyngeal carcinomas (33%) underwent conventional radiotherapy and concurrent platinum-based chemotherapy with curative intent. Sixty-two patients were male (75.6%). The median age was 59 years. Eighteen patients (22%) were in Stage III and 64 (78%) were in Stage IV. The median radiation dose was 70 Gy. The median potential follow-up was 3.9 years. Results: Overall survival and disease-free survival were respectively 63% and 73% at 3 years. Complete response rate from CRT was 75%. Nineteen patients (23%) experienced significant long-term toxicity after CRT: 6 (7.3%) required a percutaneous endoscopic gastrostomy, 5 (6%) had persistent Grade 2 or 3 dysphagia, 2 (2.4%) had pharyngoesophageal stenosis requiring multiple dilations, 2 (2.4%) had chronic lung aspiration, and 7 (8.5%) required a permanent tracheostomy. Four patients (4.9%) underwent laryngectomy without pathologic evidence of disease. At last follow-up, 5 (6%) patients were still dependent on a gastrostomy. Overall, 42 patients (52%) were alive, in complete response, with a functional larynx and no other major complications. Conclusions: In our institution, CRT for advanced hypopharyngeal and laryngeal carcinoma has provided good overall survival and locoregional control in the majority of patients, but a significant proportion did not benefit from this approach because of either locoregional failure or late complications. Better organ preservation approaches are necessary to improve locoregional control and to reduce long-term toxicities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ultra-short pulse laser acceleration of protons to 80 MeV from cryogenic hydrogen jets tailored to near-critical density

Laser plasma-based particle accelerators attract great interest in fields where conventional accelerators reach limits based on size, cost or beam parameters. Despite the fact that particle in cell simulations have predicted several advantageous ion acceleration schemes, laser accelerators have not yet reached their full potential in producing simultaneous high-radiation doses at high particle energies. The most stringent limitation is the lack of a suitable high-repetition rate target that also provides a high degree of control of the plasma conditions required to access these advanced regimes. Here, we demonstrate that the interaction of petawatt-class laser pulses with a pre-formed micrometer-sized cryogenic hydrogen jet plasma overcomes these limitations enabling tailored density scans from the solid to the underdense regime. Our proof-of-concept experiment demonstrates that the near-critical plasma density profile produces proton energies of up to 80 MeV. Based on hydrodynamic and three-dimensional particle in cell simulations, transition between different acceleration schemes are shown, suggesting enhanced proton acceleration at the relativistic transparency front for the optimal case.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

WMSA for wireless communication applications

Modified rectangular compact microstrip patch antenna having finite ground plane is proposed in this paper. Wideband Microstrip Antenna (WMSA) is achieved by corner cut and inserting air gaps inside the edges of the radiating patch having finite ground plane. The obtained impedance bandwidth for 10 dB return loss for the operating frequency f{sub 0} = 2.09 GHz is 28.7 % (600 MHz), which is very high as compared to the bandwidth obtained for the conventional microstrip antenna. Compactness with wide bandwidth of this antenna is practically useful for the wireless communication systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗