Search NASA⌕ Search

SEARCH · Search NASA

Results for “Count”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Status of BetaCage: an Ultra-sensitive Screener for Surface Contamination

BetaCage, a gaseous neon time-projection chamber, has been proposed as a viable screener for emitters of low-energy alphas and electrons to which commercial radioactivity counting techniques are insensitive. Using radiopure materials for construction, active and passive shielding from extrinsic backgrounds, large counting area and minimal detector mass, BetaCage will be able to achieve sensitivities of 10{sup -5} counts keV{sup -1} kg{sup -1} day{sup -1} in a few days of running time. We report on progress in prototype development work since the last meeting of this workshop.

07 ISOTOPE AND RADIATION SOURCES↗

Linear accelerator x-ray sources with high duty cycle

X-ray cargo inspection systems typically use a several-MV pulsed linear accelerator (linac) to produce a bremsstrahlung spectrum of x rays by bombarding a target with electrons. The x rays traverse the cargo and are detected by a detector array. Spectroscopy of the detected x rays is very desirable: if one can determine the spectrum of the transmitted x rays, one can determine the Z of the material they traversed. Even in relatively low-dose modes of operation, thousands of x rays arrive at each detector element during each pulse, unless the x rays are heavily absorbed or scattered by the cargo. For portal or fixed-site systems, dose rates, and therefore x-ray count rates, are even higher. Because of the high x-ray count rate, spectroscopy is impractical in conventional cargo inspection systems, except in certain special cases. For a mobile system, typical pulse durations are a few microseconds, and the number of pulses is on the order of 100 per second, leading to a duty factor of about 0.04%. Clearly, a linear accelerator x-ray source with much higher duty factor would be useful, since then the same number of x rays could be spread out over time, reducing the x-ray count rate. In this paper, we explore the possibility of designing a linear accelerator system, using more or less Conventional Off the Shelf (COTS) components, capable of duty cycles of 1% or greater. A survey was conducted of available linac RF source options and, given the possibilities, calculations were performed for suitable beam centerline designs. Keeping in mind that the size and cost of the accelerator system should be practical for use in a mobile cargo inspection system, only a few options are shown to be reasonably feasible, both requiring the use of klystrons instead of the magnetrons used in conventional systems. An S-Band design appears clearly possible, and there is also a promising X-Band design.

43 PARTICLE ACCELERATORS↗

Synchrotron radiation-based Mössbauer spectra of {sup 174}Yb measured with internal conversion electrons

A detection system for synchrotron-radiation (SR)-based Mössbauer spectroscopy was developed to enhance the nuclear resonant scattering counting rate and thus increase the available nuclides. In the system, a windowless avalanche photodiode (APD) detector was combined with a vacuum cryostat to detect the internal conversion (IC) electrons and fluorescent X-rays accompanied by nuclear de-excitation. As a feasibility study, the SR-based Mössbauer spectrum using the 76.5 keV level of {sup 174}Yb was observed without {sup 174}Yb enrichment of the samples. The counting rate was five times higher than that of our previous system, and the spectrum was obtained within 10 h. This result shows that nuclear resonance events can be more efficiently detected by counting IC electrons for nuclides with high IC coefficients. Furthermore, the windowless detection system enables us to place the sample closer to the APD elements and is advantageous for nuclear resonant inelastic scattering measurements. Therefore, this detection system can not only increase the number of nuclides accessible in SR-based Mössbauer spectroscopy but also allows the nuclear resonant inelastic scattering measurements of small single crystals or enzymes with dilute probe nuclides that are difficult to measure with the previous detection system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A new clocking method for a charge coupled device

We propose and demonstrate a new clocking method for a charge-coupled device (CCD). When a CCD is used for a photon counting detector of X-rays, its weak point is a limitation of its counting rate, because high counting rate makes non-negligible pile-up of photons. In astronomical usage, this pile-up is especially severe for an observation of a bright point-like object. One typical idea to reduce the pile-up is a parallel sum (P-sum) mode. This mode completely loses one-dimensional information. Our new clocking method, panning mode, provides complementary properties between the normal mode and the P-sum mode. We performed a simple simulation in order to investigate a pile-up probability and compared the simulated result and actual obtained event rates. Using this simulation and the experimental results, we compared the pile-up tolerance of various clocking modes including our new method and also compared their other characteristics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress in development of the neutron profile monitor for the large helical device

The neutron profile monitor stably operated at a high-count-rate for deuterium operations in the Large Helical Device has been developed to enhance the research on the fast-ion confinement. It is composed of a multichannel collimator, scintillation-detectors, and a field programmable gate array circuit. The entire neutron detector system was tested using an accelerator-based neutron generator. This system stably acquires the pulse data without any data loss at high-count-rate conditions up to 8 × 10{sup 5} counts per second.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Instrument for precision long-term β-decay rate measurements

We describe an experimental setup for making precision measurements of relative β-decay rates of {sup 22}Na, {sup 36}Cl, {sup 54}Mn, {sup 60}Co, {sup 90}Sr, {sup 133}Ba, {sup 137}Cs, {sup 152}Eu, and {sup 154}Eu. The radioactive samples are mounted in two automated sample changers that sequentially position the samples with high spatial precision in front of sets of detectors. The set of detectors for one sample changer consists of four Geiger-Müller (GM) tubes and the other set of detectors consists of two NaI scintillators. The statistical uncertainty in the count rate is few times 0.01% per day for the GM detectors and about 0.01% per hour on the NaI detectors. The sample changers, detectors, and associated electronics are housed in a sealed chamber held at constant absolute pressure, humidity, and temperature to isolate the experiment from environmental variations. The apparatus is designed to accumulate statistics over many years in a regulated environment to test recent claims of small annual variations in the decay rates. We demonstrate that absent this environmental regulation, uncontrolled natural atmospheric pressure variations at our location would imprint an annual signal of 0.1% on the Geiger-Müller count rate. However, neither natural pressure variations nor plausible indoor room temperature variations cause a discernible influence on our NaI scintillator detector count rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Individual heteroatom identification with X-ray spectroscopy

Individual heteroatoms in nanoscale materials often play a pivotal role in materials properties. To obtain maximum control over materials properties, researchers must be able to detect and identify diverse heteroatoms in samples with varying thickness and composition. Here, we demonstrate the identification of individual Si, S, P, and Ca heteroatoms in two-phase carbonaceous nanoscale mixtures with energy dispersive X-ray spectroscopy in a scanning transmission electron microscope. In order to fully demonstrate the robustness of the technique and the potential advantages over electron energy loss spectroscopy for single-atom speciation, no a priori constraint was placed on the sample thickness or types of heteroatom species. The various heteroatoms were identified with X-ray spectrum collection times ranging from 8 to 57 s, and normalized count rates of 0.096–0.007 counts s{sup −1} pA{sup −1}. The lowest times/highest effective count rates were achieved by maximizing the effective dwell time on the atom, through minimizing the oversampling area of the electron beam raster.

36 MATERIALS SCIENCE↗

Upgrading a high-throughput spectrometer for high-frequency (<400 kHz) measurements

The upgraded spectrometer used for charge exchange recombination spectroscopy on the Madison Symmetric Torus resolves emission fluctuations up to 400 kHz. The transimpedance amplifier’s cutoff frequency was increased based upon simulations comparing the change in the measured photon counts for time-dynamic signals. We modeled each signal-processing stage of the diagnostic and scanned the filtering frequency to quantify the uncertainty in the photon counting rate. This modeling showed that uncertainties can be calculated based on assuming each amplification stage is a Poisson process and by calibrating the photon counting rate with a DC light source to address additional variation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EVOLUTION OF X-RAY SPECTRA AND LIGHT CURVES OF V1494 AQUILAE

We present six Chandra X-ray spectra and light curves obtained for the nova V1494 Aql (1999 No. 2) in outburst. The first three observations were taken with the Advanced CCD Imaging Spectrometer (ACIS-I) on days 134, 187, and 248 after outburst. The count rates were 1.00, 0.69, and 0.53 counts s{sup -1}, respectively. We found no significant periodicity in the ACIS light curves. The X-ray spectra show continuum emission and lines originating from N and O. We found acceptable spectral fits using isothermal APEC models with significantly increased elemental abundances of O and N for all observations. On day 248 after outburst a bright soft component appeared in addition to the fading emission lines. The Chandra observations on days 300, 304, and 727 were carried out with the High Resolution Camera/Low Energy Transmission Grating Spectrometer (LETGS). The spectra consist of continuum emission plus strong emission lines of O and N, implying a high abundance of these elements. On day 300, a flare occurred and periodic oscillations were detected in the light curves taken on days 300 and 304. This flare must have originated deep in the outflowing material since it was variable on short timescales. The spectra extracted immediately before and after the flare are remarkably similar, implying that the flare was an extremely isolated event. Our attempts to fit blackbody, cloudy, or APEC models to the LETGS spectra failed, owing to the difficulty in disentangling continuum and emission-line components. The spectrum extracted during the flare shows a significant increase in the strengths of many of the lines and the appearance of several previously undetected lines. In addition, some of the lines seen before and after the flare are not present during the flare. On day 727 only the count rate from the zeroth order could be derived, and the source was too faint for the extraction of a light curve or spectrum.

79 ASTRONOMY AND ASTROPHYSICS↗

METHODS FOR ESTIMATING FLUXES AND ABSORPTIONS OF FAINT X-RAY SOURCES

X-ray sources with very few counts can be identified with low-noise X-ray detectors such as the Advanced CCD Imaging Spectrometer on board the Chandra X-ray Observatory. These sources are often too faint for parametric spectral modeling using well-established methods such as fitting with XSPEC. We discuss the estimation of apparent and intrinsic broadband X-ray fluxes and soft X-ray absorption from gas along the line of sight to these sources, using nonparametric methods. Apparent flux is estimated from the ratio of the source count rate to the instrumental effective area averaged over the chosen band. Absorption, intrinsic flux, and errors on these quantities are estimated from comparison of source photometric quantities with those of high signal-to-noise spectra that were simulated using spectral models characteristic of the class of astrophysical sources under study. The concept of this method is similar to the long-standing use of color-magnitude diagrams in optical and infrared astronomy, with X-ray median energy replacing color index and X-ray source counts replacing magnitude. Our nonparametric method is tested against the apparent spectra of approx2000 faint sources in the Chandra observation of the rich young stellar cluster in the M 17 H II region. We show that the intrinsic X-ray properties can be determined with little bias and reasonable accuracy using these observable photometric quantities without employing often uncertain and time-consuming methods of nonlinear parametric spectral modeling. Our method is calibrated for thermal spectra characteristic of stars in young stellar clusters, but recalibration should be possible for some other classes of faint X-ray sources such as extragalactic active galactic nuclei.

79 ASTRONOMY AND ASTROPHYSICS↗

A MULTIPHASE SUZAKU STUDY OF X-RAYS FROM {tau} Sco

We obtained relatively high signal-to-noise X-ray spectral data of the early massive star {tau} Sco (B0.2V) with the Suzaku X-ray Imaging Spectrometer (XIS) instrument. This source displays several unusual features that motivated our study: (1) redshifted absorption in UV P Cygni lines to approximately +250 km s{sup -1} suggestive of infalling gas, (2) unusually hard X-ray emission requiring hot plasma at temperatures in excess of 10 MK whereas most massive stars show relatively soft X-rays at a few MK, and (3) a complex photospheric magnetic field of open and closed field lines. In an attempt to understand the hard component better, X-ray data were obtained at six roughly equally spaced phases within the same epoch of {tau} Sco's 41 day rotation period. The XIS instrument has three operable detectors: XIS1 is back-illuminated with sensitivity down to 0.2 keV; XIS0 and XIS2 are front-illuminated with sensitivity only down to 0.4 keV and have an overall less effective area than XIS1. The XIS0 and XIS3 detectors show relatively little variability. In contrast, there is a {approx}4{sigma} detection of a {approx}4% drop in the count rate of the XIS1 detector at one rotational phase. In addition, all three detectors show a {approx}3% increase in count rate at the same phase. The most optimistic prediction of X-ray variability allows for a 40% change in the count rate, particularly near phases where we have pointings. Observed modulations in the X-ray light curve on the rotation cycle is an order of magnitude smaller than this, which places new stringent constraints on future modeling of this interesting magnetic massive star.

79 ASTRONOMY AND ASTROPHYSICS↗

THE EAST-WEST METHOD: AN EXPOSURE-INDEPENDENT METHOD TO SEARCH FOR LARGE-SCALE ANISOTROPIES OF COSMIC RAYS

The measurement of large-scale anisotropies in cosmic ray arrival directions at energies above 10{sup 13} eV is performed through the detection of extensive air showers (EAS) produced by cosmic ray interactions in the atmosphere. The observed anisotropies are small, so accurate measurements require small statistical uncertainties, i.e., large data sets. These can be obtained by employing ground detector arrays with large extensions (from 10{sup 4} to 10{sup 9} m{sup 2}) and long operation time (up to 20 years). The control of such arrays is challenging and spurious variations in the counting rate due to instrumental effects (e.g., data taking interruptions or changes in the acceptance) and atmospheric effects (e.g., air temperature and pressure effects on EAS development) are usually present. These modulations must be corrected very precisely before performing standard anisotropy analyses, i.e., harmonic analysis of the counting rate versus local sidereal time. In this paper we discuss an alternative method to measure large-scale anisotropies, the 'East-West method'. It was originally proposed in the 1940s to study asymmetries in the flux of solar cosmic rays and later applied by Nagashima et al. to EAS at higher energies. It is a differential method, as it is based on the analysis of the difference of the counting rates in the east and west directions. Besides explaining the principle, we present here its mathematical derivation, showing that the method is largely independent of experimental effects, that is, it does not require corrections for acceptance and/or for atmospheric effects. We explain the use of the method to derive the amplitude and phase of the anisotropy and demonstrate its power under different conditions of detector operation.

79 ASTRONOMY AND ASTROPHYSICS↗

NEMA NU4-2008 performance evaluation for the microPET FOCUS 120 and iodine-124

This study aimed to evaluate the performance of the microPET FOCUS 120 in terms of counting rate capability and image quality when using {sup 124}I. The noise equivalent count rate (NECR) index was defined as: NECR = R{sub T}{sup 2}/R{sub P} + R{sub GP} (T = true, P = prompt, GP = gamma prompt). The maximum NECR (48 kcps) value was obtained for the 250-590 keV energy window (EW) with 6 ns time window (TW). The two other EW (350-590 and 350-650 keV) gave comparable maximum NECR of 43 kcps for the 6 ns TW. The 2 ns TW reduced the NECR by 45 to 50 % Scatter and gamma plus scatter fractions were almost not TW dependent. The 250-590 keV window showed the largest scatter fraction with 23% For the NEMA NU4-2008 image quality phantom, coefficients of variation in the uniform part increased from about 8 to 12% when decreasing TW from 6 to 2 ns. The lowest spill-over-ratios (SOR) for the non emitting regions were obtained for the 350-590 and 350-650 keV EW. Recovery coefficients (RC) of the hot rods were the highest for the 350-590 keV EW and 2 ns TW. Scatter correction led to a decrease in RC and occasionally (with FBP or 3DRP) to a negative value for the SOR. The combination of the 350-590 keV energy window with 6 ns time window appeared to be a good compromise between counting rate capability and image quality for the FOCUS 120, especially when MAP reconstruction was used. The scatter correction algorithm provided by the constructor should be used with caution. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hypothesis tests for the detection of constant speed radiation moving sources

Radiation Portal Monitors are deployed in linear network to detect radiological material in motion. As a complement to single and multichannel detection algorithms, inefficient under too low signal to noise ratios, temporal correlation algorithms have been introduced. Test hypothesis methods based on empirically estimated mean and variance of the signals delivered by the different channels have shown significant gain in terms of a tradeoff between detection sensitivity and false alarm probability. This paper discloses the concept of a new hypothesis test for temporal correlation detection methods, taking advantage of the Poisson nature of the registered counting signals, and establishes a benchmark between this test and its empirical counterpart. The simulation study validates that in the four relevant configurations of a pedestrian source carrier under respectively high and low count rate radioactive background, and a vehicle source carrier under the same respectively high and low count rate radioactive background, the newly introduced hypothesis test ensures a significantly improved compromise between sensitivity and false alarm, while guaranteeing the stability of its optimization parameter regardless of signal to noise ratio variations between 2 to 0.8. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-C-9A-04: Alternative Analytic Solution to the Paralyzable Detector Model to Calculate Deadtime and Deadtime Loss

Purpose: Some common methods to solve for deadtime are (1) dual-source method, which assumes two equal activities; (2) model fitting, which requires multiple acquisitions as source decays; and (3) lossless model, which assumes no deadtime loss at low count rates. We propose a new analytic alternative solution to calculate deadtime for paralyzable gamma camera. Methods: Deadtime T can be calculated analytically from two distinct observed count rates M1 and M2 when the ratio of the true count rates alpha=N2/N1 is known. Alpha can be measured as a ratio of two measured activities using dose calibrators or via radioactive decay. Knowledge of alpha creates a system with 2 equations and 2 unknowns, i.e., T and N1. To verify the validity of the proposed method, projections of a non-uniform phantom (4GBq 99mTc) were acquired in using Siemens SymbiaS multiple times over 48 hours. Each projection has >100kcts. The deadtime for each projection was calculated by fitting the data to a paralyzable model and also by using the proposed 2-acquisition method. The two estimates of deadtime were compared using the Bland-Altmann method. In addition, the dependency of uncertainty in T on uncertainty in alpha was investigated for several imaging conditions. Results: The results strongly suggest that the 2-acquisition method is equivalent to the fitting method. The Bland-Altman analysis yielded mean difference in deadtime estimate of ∼0.076us (95%CI: -0.049us, 0.103us) between the 2-acquisition and model fitting methods. The 95% limits of agreement were calculated to be -0.104 to 0.256us. The uncertainty in deadtime calculated using the proposed method is highly dependent on the uncertainty in the ratio alpha. Conclusion: The 2-acquisition method was found to be equivalent to the parameter fitting method. The proposed method offers a simpler and more practical way to analytically solve for a paralyzable detector deadtime, especially during physics testing.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-I-88: The Effect of System Dead Time On Real-Time Plastic and GOS Based Fiber-Optic Dosimetry Systems

Purpose: A methodology is presented to correct for measurement inaccuracies at high detector count rates using a plastic and GOS scintillation fibers coupled to a photomultiplier tube with digital readout. This system allows temporal acquisition and manipulation of measured data. Methods: The detection system used was a plastic scintillator and a separate gadolinium scintillator, both (0.5 diameter) coupled to an optical fiber with a Hamamatsu photon counter with a built-in microcontroller and digital interface. Count rate performance of the system was evaluated using the nonparalzable detector model. Detector response was investigated across multiple radiation sources including: orthovoltage x-ray system, colbat-60 gamma rays, proton therapy beam, and a diagnostic radiography x-ray tube. The dead time parameter was calculated by measuring the count rate of the system at different exposure rates using a reference detector. Results: The system dead time was evaluated for the following sources of radiation used clinically: diagnostic energy x-rays, cobalt-60 gamma rays, orthovoltage xrays, particle proton accelerator, and megavoltage x-rays. It was found that dead time increased significantly when exposing the detector to sources capable of generating Cerenkov radiation, all of the sources sans the diagnostic x-rays, with increasing prominence at higher photon energies. Percent depth dose curves generated by a dedicated ionization chamber and compared to the detection system demonstrated that correcting for dead time improves accuracy. On most sources, nonparalzable model fit provided an improved system response. Conclusion: Overall, the system dead time was variable across the investigated radiation particles and energies. It was demonstrated that the system response accuracy was greatly improved by correcting for dead time effects. Cerenkov radiation plays a significant role in the increase in the system dead time through transient absorption effects attributed to electron hole-pair creations within the optical waveguide.

07 ISOTOPE AND RADIATION SOURCES↗

NEMA NU 2-2012 performance studies for the SiPM-based ToF-PET component of the GE SIGNA PET/MR system

Purpose: The GE SIGNA PET/MR is a new whole body integrated time-of-flight (ToF)-PET/MR scanner from GE Healthcare. The system is capable of simultaneous PET and MR image acquisition with sub-400 ps coincidence time resolution. Simultaneous PET/MR holds great potential as a method of interrogating molecular, functional, and anatomical parameters in clinical disease in one study. Despite the complementary imaging capabilities of PET and MRI, their respective hardware tends to be incompatible due to mutual interference. In this work, the GE SIGNA PET/MR is evaluated in terms of PET performance and the potential effects of interference from MRI operation. Methods: The NEMA NU 2-2012 protocol was followed to measure PET performance parameters including spatial resolution, noise equivalent count rate, sensitivity, accuracy, and image quality. Each of these tests was performed both with the MR subsystem idle and with continuous MR pulsing for the duration of the PET data acquisition. Most measurements were repeated at three separate test sites where the system is installed. Results: The scanner has achieved an average of 4.4, 4.1, and 5.3 mm full width at half maximum radial, tangential, and axial spatial resolutions, respectively, at 1 cm from the transaxial FOV center. The peak noise equivalent count rate (NECR) of 218 kcps and a scatter fraction of 43.6% are reached at an activity concentration of 17.8 kBq/ml. Sensitivity at the center position is 23.3 cps/kBq. The maximum relative slice count rate error below peak NECR was 3.3%, and the residual error from attenuation and scatter corrections was 3.6%. Continuous MR pulsing had either no effect or a minor effect on each measurement. Conclusions: Performance measurements of the ToF-PET whole body GE SIGNA PET/MR system indicate that it is a promising new simultaneous imaging platform.

60 APPLIED LIFE SCIENCES↗

SU-F-R-55: Early Detection of Treatment Induced Bone Marrow Injury During Chemoradiation Therapy Using Quantitative CT

Purpose: Acute hematologic toxicity associated with bone marrow injury is a common complication of chemoradiation therapy (CRT) for pelvic malignancies. In this work, we investigate the feasibility of using quantitative CT to detect bone marrow injury during CRT. Methods: Daily CTs were acquired during routine CT-guided radiation therapy using a CT-on-rails for 15 cervical cancer patients. All patients treated with a radiation dose of 45.0 to 50.4 Gy in 1.8 Gy/fraction along with chemotherapy. For each patient, the contours of bone marrow were generated in L4, L5 and sacrum on the first daily CT and then populated to other daily CTs by rigid registration using MIM (MIM Software Inc., Cleveland, OH) with manual editing if possible. A series of CT texture parameters, including Hunsfield Unit (HU) histogram, mean HU, entropy, energy, in bone marrow contours were calculated using MATLAB on each daily CT and were correlated with the completed blood counts (CBC) collected weekly for each patient. The correlations were analyzed with Pearson correlation tests. Results: For all patient data analyzed, mean HU in bone marrow decreased during CRT delivery. From the first to the last fraction the average mean HU reduction is 58.1 ± 13.6 HU (P<0.01). This decrease can be observed as early as after first 5 fractions and is strongly associated with the changes of most CBC quantities, such as the reductions of white and blood cell counts (r=0.97, P=0.001). The reduction of HU is spatially varied. Conclusion: Chemoradiation induced bone marrow injury can be detected during the delivery of CRT using quantitative CT. Chemoradiation results in reductions in mean HU, which are strongly associated with the change in the pretrial blood cell counts. Early detection of bone marrow injury with commonly available CT opens a door to improve bone marrow sparing, reducing risk of hematologic toxicity.

60 APPLIED LIFE SCIENCES↗