Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data Transfer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Data storage and retrieval system

The Data Storage and Retrieval System (DSRS) consists of off-the-shelf system components integrated as a file server supporting very large files. These files are on the order of one gigabyte of data per file, although smaller files on the order of one megabyte can be accommodated as well. For instance, one gigabyte of data occupies approximately six 9-track tape reels (recorded at 6250 bpi). Due to this large volume of media, it was desirable to 'shrink' the size of the proposed media to a single portable cassette. In addition to large size, a key requirement was that the data needs to be transferred to a (VME based) workstation at very high data rates. One gigabyte (GB) of data needed to be transferred from an archiveable media on a file server to a workstation in less than 5 minutes. Equivalent size, on-line data needed to be transferred in less than 3 minutes. These requirements imply effective transfer rates on the order of four to eight megabytes per second (4-8 MB/s). The DSRS also needed to be able to send and receive data from a variety of other sources accessible from an Ethernet local area network.

Nakamoto, Glen↗

Space shuttle: Heat transfer rate measurements on Convair booster (B-15B-2) at nominal Mach number of 8

Plotted and tabulated data on heat transfer from a thin-skin thermocouple are presented. The data is representative of the reentry event of the booster alone configuration. The data were generated during wind tunnel tests of the B-15B-2 delta wing booster at Mach 8. Thermocouple measurements are reduced to heat transfer coefficient ratio and the data are presented as plotted variations versus longitudinal, lateral, and vertical local model positions.

Warmbrod, J. D.↗

In Tube Condensation Heat Transfer and Pressure Drop for R454B and R32—Potential Replacements for R410A

The heating, ventilation and air conditioning (HVAC) industry in the United States seeks near-term alternative refrigerants to replace R-410A in unitary equipment. Two potential replacement refrigerants are R-454B and R-32. It is of interest to investigate the capability and accuracy of existing heat exchanger design methods when applied to these replacement refrigerants. To that end, this work presents empirical condensation quasi-local heat transfer coefficient and pressure drop data for R-454B and R-32. These data were obtained in a $\frac{3}{8}$ in. (9.52 mm) outside diameter (OD) smooth copper tube with a wall thickness of 0.032 in. (0.81 mm). The experimental variables and their ranges included refrigerant absolute pressure ( 1960 ≤ P a b s ≤ 3196 kPa), condensation temperature ( 35 ≤ T c o n d ≤ 50 °C), mass flux ( 100 ≤ G ≤ 200 kg m -2 s -1 ), vapor quality ( 0 ≤ x ≤ 1 ), and heat flux ( 32.9 ≤ q ″ ≤ 62.97 kW m -2 ). It was found that the heat transfer correlation developed by Cavallini et al. Cavallini et al. (2006) predicted the experimental condensation heat transfer data, for both R-454B and R-32, with the greatest accuracy. Using the Cavallini et al. correlation, it was found that the mean absolute percentage error (MAPE) was 10.5% and 15.1% for R-454B and R-32, respectively. Additionally, the pressure drop correlation developed by Friedel Friedel (1979) predicted the experimentally determined pressure gradient with a MAPE of 7.7% and 5.5% for R-454B and R-32, respectively. These results will assist the practicing thermal engineer to choose the most appropriate design correlation for these near-term replacement refrigerants.

42 ENGINEERING↗

QProR: An Efficient Framework for Quantity-of-Interest Based Progressive Retrieval with Guaranteed Error Control

Scientific applications generate an unprecedented volume of data, overwhelming the network and file systems’ bandwidth and posing challenges for efficient and scalable data retrieval and analysis. Progressive data compression offers a promising solution by enabling on-demand retrieval at reduced size. However, existing progressive methods either fail to bound the errors in essential quantities of interest (QoIs) derived from raw data or suffer from suboptimal retrieval efficiency. In this work, we propose QProR, an efficient QoI-based progressive framework that optimizes progressive retrieval for target QoIs. Our key contributions include: (1) a systematic framework that integrates error-controlled lossy compressors with bitplane encoding while decoupling the two processes for high flexibility and adaptability; (2) a novel weighted bitplane encoding method which incorperates QoI knowledge into data refactoring to enhance retrieval efficiency; (3) an optimized retrieval strategy that accounts for the varying impacts of different variables on multivariate QoIs; (4) comprehensive evaluations using six real-world datasets from multiple scientific applications and thorough comparisons against state of the arts. Experimental results demonstrate that QProR achieves up to 80.38% reduction in the retrieval size under the same requested QoI error tolerance, when compared with the best-performing existing methods. When transferring 384 GB of scientific data to remote sites, QProR delivers up to 1.68 × speedup in the end-to-end data transfer performance.

Li, Wenbo [University of Kentucky]↗

JANUS: Resilient and Adaptive Data Transmission for Enabling Timely and Efficient Cross-Facility Scientific Workflows

In modern science, the growing complexity of large-scale scientific projects has led to an increasing reliance on cross-facility scientific workflows, where resources and expertise from multiple institutions and geographic locations are leveraged to accelerate scientific discovery. These workflows often require transmitting huge amounts of scientific data through wide-area networks. Although high-speed networks like ESnet and transfer services such as Globus have improved data mobility, several challenges remain. The sheer volume of data can overwhelm network bandwidth, widely used transport protocols such as TCP suffer from inefficiencies due to retransmissions triggered by packet loss, and existing fault-tolerance mechanisms like erasure coding introduce substantial overhead. In this paper, we propose Janus, a resilient and adaptable data transmission approach designed for cross-facility scientific workflows. Unlike traditional TCP-based methods, Janus leverages UDP, integrates erasure coding for fault tolerance, and combines it with error-bounded lossy compression to reduce overhead. This novel design allows users to balance data transmission time and accuracy, optimizing transfer performance based on specific scientific requirements. Additionally, Janus dynamically adjusts erasure coding parameters in response to real-time network conditions, ensuring efficient data transfers even in fluctuating environments. We develop optimization models for determining ideal configurations and implement adaptive data transfer protocols to enhance reliability. Through extensive simulations and real-network experiments, we demonstrate that Janus significantly improves transfer efficiency while maintaining data fidelity.

Esaulov, Vladislav [Georgia State University, Atla↗

Experimental Investigation of Average Heat-Transfer and Friction Coefficients for Air Flowing in Circular Tubes Having Square-Thread-Type Roughness

An investigation of forced-convection heat transfer and associated pressure drops was conducted with air flowing through electrically heated Inconel tubes having various degrees of square-thread-type roughness, an inside diameter of 1/2 inch, and a length of 24 inches. were obtained for tubes having conventional roughness ratios (height of thread/radius of tube) of 0 (smooth tube), 0.016, 0.025, and 0.037 over ranges of bulk Reynolds numbers up to 350,000, average inside-tube-wall temperatures up to 1950deg R, and heat-flux densities up to 115,000 Btu per hour per square foot. Data The experimental data showed that both heat transfer and friction increased with increase in surface roughness, becoming more pronounced with increase in Reynolds number; for a given roughness, both heat transfer and friction were also influenced by the tube wall-to-bulk temperature ratio. Good correlation of the heat-transfer data for all the tubes investigated was obtained by use of a modification of the conventional Nusselt correlation parameters wherein the mass velocity in the Reynolds number was replaced by the product of air density evaluated at the average film temperature and the so-called friction velocity; in addition, the physical properties of air were evaluated at the average film temperature. The isothermal friction data for the rough tubes, when plotted in the conventional manner, resulted in curves similar to those obtained by other investigators; that is, the curve for a given roughness breaks away from the Blasius line (representing turbulent flow in smooth tubes) at some value of Reynolds number, which decreases with increase in surface roughness, and then becomes a horizontal line (friction coefficient independent of Reynolds number). A comparison of the friction data for the rough tubes used herein indicated that the conventional roughness ratio is not an adequate measure of relative roughness for tubes having a square-thread-type element. The present data, as well as those of other investigators, were used to isolate the influence of ratios of thread height to width, thread spacing to width, and the conventional roughness ratio on the friction coefficient. A fair correlation of the friction data was obtained for each tube with heat addition when the friction coefficient and Reynolds number were defined on the basis of film properties; however, the data for each tube retained the curve characteristic of that particular roughness. The friction data for all the rough tubes could be represented by a single line for the complete turbulence region by incorporating a roughness parameter in the film correlation. No correlation was obtained for the region of incomplete turbulence.

Sams, E. W.↗

Place polarized neutron reflectivity data in bins of constant wavevector transfer

Code to place polarized neutron reflectivity into bins of constant Qz with regard for Zeeman energy change to the spin-flip channel. The code is written as a Jupyter notebook. Example data are included as separate files (spin_down.txt and spin_up.txt). As a first step, run all cells in the notebook. Opportunities are identified for users to make their own choices for analysis of the data. The code is written to be a stand-alone operation on data collected from a pulse neutron source that have been previously normalized to the wavelength dependence of the incident beam spectrum, background subtracted, etc. The constant Qz binning (this code) is the last step to perform in the analysis (reduction) workflow. This step yields the the reflectivities for the four neutron spin cross-sections. A future intention is to create a version of this code that will be one module of many in the data analysis workflow.

Fitzsimmons, Michael [Oak Ridge National Lab. (ORN↗

High Density Digital Data Storage System

The High Density Digital Data Storage System was designed to provide a cost effective means for storing real-time data from the field-deployable digital acoustic measurement system. However, the high density data storage system is a standalone system that could provide a storage solution for many other real time data acquisition applications. The storage system has inputs for up to 20 channels of 16-bit digital data. The high density tape recorders presently being used in the storage system are capable of storing over 5 gigabytes of data at overall transfer rates of 500 kilobytes per second. However, through the use of data compression techniques the system storage capacity and transfer rate can be doubled. Two tape recorders have been incorporated into the storage system to produce a backup tape of data in real-time. An analog output is provided for each data channel as a means of monitoring the data as it is being recorded.

Wright, Kenneth D., II↗

Transfer function characteristics of super resolving systems

Signal quality in an optical storage device greatly depends on the optical system transfer function used to write and read data patterns. The problem is similar to analysis of scanning optical microscopes. Hopkins and Braat have analyzed write-once-read-many (WORM) optical data storage devices. Herein, transfer function analysis of magnetooptic (MO) data storage devices is discussed with respect to improving transfer-function characteristics. Several authors have described improving the transfer function as super resolution. However, none have thoroughly analyzed the MO optical system and effects of the medium. Both the optical system transfer function and effects of the medium of this development are discussed.

Milster, Tom D.↗

Data-Driven Reduced-Order Modeling of Convective Heat Transfer in Porous Media

This work presents a data-driven Reduced-Order Model (ROM) for parametric convective heat transfer problems in porous media. The intrusive Proper Orthogonal Decomposition aided Reduced-Basis (POD-RB) technique is employed to reduce the porous medium formulation of the incompressible Reynolds-Averaged Navier–Stokes (RANS) equations coupled with heat transfer. Instead of resolving the exact flow configuration with high fidelity, the porous medium formulation solves a homogenized flow in which the fluid-structure interactions are captured via volumetric flow resistances with nonlinear, semi-empirical friction correlations. A supremizer approach is implemented for the stabilization of the reduced fluid dynamics equations. The reduced nonlinear flow resistances are treated using the Discrete Empirical Interpolation Method (DEIM), while the turbulent eddy viscosity and diffusivity are approximated by adopting a Radial Basis Function (RBF) interpolation-based approach. The proposed method is tested using a 2D numerical model of the Molten Salt Fast Reactor (MSFR), which involves the simulation of both clean and porous medium regions in the same domain. For the steady-state example, five model parameters are considered to be uncertain: the magnitude of the pumping force, the external coolant temperature, the heat transfer coefficient, the thermal expansion coefficient, and the Prandtl number. For transient scenarios, on the other hand, the coastdown-time of the pump is the only uncertain parameter. The results indicate that the POD-RB-ROMs are suitable for the reduction of similar problems. The relative L2 errors are below 3.34% for every field of interest for all cases analyzed, while the speedup factors vary between 54 (transient) and 40,000 (steady-state).

German, Péter (ORCID:0000000307285283)↗

Optimizing Error-Bounded Lossy Compression for Scientific Data by Dynamic Spline Interpolation

Today's scientific simulations are producing vast volumes of data that cannot be stored and transferred efficiently because of limited storage capacity, parallel I/O bandwidth, and network bandwidth. The situation is getting worse over time because of the ever-increasing gap between relatively slow data transfer speed and fast-growing computation power in modern supercomputers. Error-bounded lossy compression is becoming one of the most critical techniques for resolving the big scientific data issue, in that it can significantly reduce the scientific data volume while guaranteeing that the reconstructed data is valid for users because of its compression-error-bounding feature. In this paper, we present a novel error-bounded lossy compressor based on a state-of-the-art prediction-based compression framework. Our solution exhibits substantially better compression quality than all of the existing error-bounded lossy compressors, with comparable compression speed. Specifically, our contribution is threefold. (1) We provide an in-depth analysis of why the best-existing prediction-based lossy compressor can only minimally improve the compression quality. (2) We propose a dynamic spline interpolation approach with a series of optimization strategies that can significantly improve the data prediction accuracy, substantially improving the compression quality in turn. (3) We perform a thorough evaluation using six real-world scientific simulation datasets across different science domains to evaluate our solution vs. all other related works. Experiments show that the compression ratio of our solution is higher than that of the second-best lossy compressor by 20%similar to 460% with the same error bound in most of the cases.

Zhao, Kai↗

Polymorphic Phase Control of RDX-Based Explosives

The polymorphic phase of 1,3,5-trinitro-1,3,5-triazine (RDX) was examined as a function of mass loading, solvent, and sample deposition technique. When RDX was deposited at a high mass loading, the vibrational modes in the obtained Raman spectra were indicative of concomitant polymorphism as both the α-RDX and β-RDX phases were present. At low mass loadings, only β-RDX was observed regardless of solvent when using the drop cast crystallization method. However, α-RDX (the thermodynamically stable polymorphic phase observed with visible quantities of the explosive) was observed when RDX deposits were dry transferred. Observation of α-RDX was independent of the initial mass loading or the initial deposition solvent when using the dry transfer methodology. These data indicate that the use of the dry transfer preparation method can be used to successfully prepare RDX-based test articles with the α-RDX phase regardless of the solvent used to initially dissolve the RDX, the initial deposition technique, or the mass loading.

Brady, John J.↗

Communication Pathways in the Light Water Reactor Sustainability Online Monitoring Project

Implementation of online monitoring and prognostics in existing U.S. nuclear power plants will involve coordinating the efforts of national laboratories, utilities, universities, and private companies. Large amounts of operational data, including failure data, are necessary for the development and calibration of diagnostic and prognostic algorithms. The ability to use data from all available resources will provide the most expeditious avenue to implementation of online monitoring in existing NPPs; however, operational plant data are often considered proprietary. Secure methods for transferring and storing data are discussed, along with a potential technology for implementation of online monitoring.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Reduction and analysis of ATS-6 data

A data reduction program was developed and debugged which presents the Aerospace particle data and the UCLA magnetometer data in a variety of formats suitable for analysis as well as further data processing. Fifty days of data were processed through this program and analysis of these data were begun. In addition, modifications were made to an old ATS-1 program in order to enable this program to process ATS-1 data obtained simultaneously with ATS-6 data acquisitions during 1974. Some analysis of ATS-1 data and comparison with ATS-6 data also went forward. Preparations were begun to transfer ATS-6 data to the National Space Science Data Center. These efforts are described in detail.

Paulikas, G. A.↗

The GONG Data Reduction and Analysis System

Each of the six GONG observing stations will produce three, 16-bit, 256X256 images of the Sun every 60 sec of sunlight. These data will be transferred from the observing sites to the GONG Data Management and Analysis Center (DMAC), in Tucson, on high-density tapes at a combined rate of over 1 gibabyte per day. The contemporaneous processing of these data will produce several standard data products and will require a sustained throughput in excess of 7 megaflops. Peak rates may exceed 50 megaflops. Archives will accumulate at the rate of approximately 1 terabyte per year, reaching nearly 3 terabytes in 3 yr of observing. Researchers will access the data products with a machine-independent GONG Reduction and Analysis Software Package (GRASP). Based on the Image Reduction and Analysis Facility, this package will include database facilities and helioseismic analysis tools. Users may access the data as visitors in Tucson, or may access DMAC remotely through networks, or may process subsets of the data at their local institutions using GRASP or other systems of their choice. Elements of the system will reach the prototype stage by the end of 1988. Full operation is expected in 1992 when data acquisition begins.

Pintar, James A.↗

Automated Analysis, Reporting, and Archiving for Robotic Nondestructive Assay of Holdup Deposits - 19508

To decommission deactivated gaseous diffusion enrichment facilities, miles of contaminated pipe must be measured. The current method requires thousands of manual measurements, repeated manual data transcription, and months of manual analysis. The Pipe Crawling Activity Measurement System (PCAMS), developed by Carnegie Mellon University and in commissioning for use at the DOE Portsmouth Gaseous Diffusion Enrichment Facility, uses a robot to measure Uranium-235 from inside pipes and automatically log the data. Radiation measurements, as well as imagery, geometric modeling, and precise measurement positioning data are digitally transferred to the PCAMS server. On the server, data can be automatically processed in minutes and summarized for analyst review. Measurement reports are auto-generated with the push of a button. A database specially-configured to hold heterogeneous data such as spectra, images, and robot trajectories serves as archive. This paper outlines the features and design of the PCAMS Post-Processing Software, currently in commissioning for use at the Portsmouth Gaseous Diffusion Enrichment Facility. The analysis process, the analyst interface to the system, and the content of auto-generated reports are each described. Example pipe-interior geometric surface models, illustration of how key report features apply in operational runs, and user feedback are discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A high-speed one-dimensional detector for time-resolved small -angle X-ray scattering : design and characterization.

A high-speed one-dimensional detector for time-resolved small-angle x-ray scattering has been designed and built for experiments at the Advanced Photon Source of Argonne National Laboratory. This detector is made from a 500-?m thick by 150-mm diameter ultra-high-purity n-type silicon wafer. The electrodes, which are a series of concentric rings that are deposited in the wafer, integrate the scattered x-rays over the azimuthal angle and, thereby, produce a one-dimensional detector. This design yields 128 rings, which allows parallel processing of the signal from each ring. The readout electronics consist of transimpedance front-end amplifiers, one for each ring, followed by active pulse-shaping filters. The amplifier signals are digitized using 12-bit analog-to-digital converters, one per ring, which operate at 20 MHz. The frame rate of the system is 271 kHz. Up to 220 - 1 scattering profiles may be stored on a random access memory chip and transferred to a data file at a rate of 16 x 103 profiles/sec. For X-ray energies between 3.5 and 13.2 keV the efficiency exceeds 80%. The resolving time of the electronics is 300 ns, which is sufficient to isolate electronically a single pulse of scattered x-rays when the synchrotron is operated in a hybrid or asymmetric fill pattern. Therefore, laser-pump/x-ray-probe experiments can be performed without a mechanical shutter. Examples of time-resolved speckle and the kinetics of the formation of sodium chloride particles are presented. This detector is capable of acquiring small-angle x-ray scattering profiles over multiple time scales, which are needed to characterize many chemical, physical, and biological processes. In addition, this detector may be tested and calibrated before experimental runs, without access to an intense beam of x-rays, with alpha particles from a radioactive source such as 241Am.

43 PARTICLE ACCELERATORS↗

The relation of flux transfer events to magnetic reconnection

Preliminary results of a search for heat-transfer signatures in electron data on 31 flux-transfer events (FTEs) are reported. Strong acceleration or deceleration, large parallel pressure anisotropies, and temperatures and densities between those of the magnetosphere and the magnetosheath are commonly observed within the surface of the flux-transfer interval defined by the heat-flow peaks, with some evidence of field-aligned ionospheric electrons. A theoretical model is developed to explain some of the observations and illustrated with diagrams. Dynamical tests on a large well-resolved FTE show that the data are consistent with a one-sided passage of the probe into and out of a rotational shear layer.

Scudder, J. D.↗