Search NASA⌕ Search

SEARCH · Search NASA

Results for “Datasets”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Inter-slice bidirectional registration-based segmentation of the prostate gland in MR and CT image sequences

Purpose: Accurate segmentation and volume estimation of the prostate gland in magnetic resonance (MR) and computed tomography (CT) images are necessary steps in diagnosis, treatment, and monitoring of prostate cancer. This paper presents an algorithm for the prostate gland volume estimation based on the semiautomated segmentation of individual slices in T2-weighted MR and CT image sequences. Methods: The proposedInter-Slice Bidirectional Registration-based Segmentation (iBRS) algorithm relies on interslice image registration of volume data to segment the prostate gland without the use of an anatomical atlas. It requires the user to mark only three slices in a given volume dataset, i.e., the first, middle, and last slices. Next, the proposed algorithm uses a registration algorithm to autosegment the remaining slices. We conducted comprehensive experiments to measure the performance of the proposed algorithm using three registration methods (i.e., rigid, affine, and nonrigid techniques). Results: The results with the proposed technique were compared with manual marking using prostate MR and CT images from 117 patients. Manual marking was performed by an expert user for all 117 patients. The median accuracies for individual slices measured using the Dice similarity coefficient (DSC) were 92% and 91% for MR and CT images, respectively. The iBRS algorithm was also evaluated regarding user variability, which confirmed that the algorithm was robust to interuser variability when marking the prostate gland. Conclusions: The proposed algorithm exploits the interslice data redundancy of the images in a volume dataset of MR and CT images and eliminates the need for an atlas, minimizing the computational cost while producing highly accurate results which are robust to interuser variability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modification of the TASMIP x-ray spectral model for the simulation of microfocus x-ray sources

Purpose: The availability of accurate and simple models for the estimation of x-ray spectra is of great importance for system simulation, optimization, or inclusion of photon energy information into data processing. There is a variety of publicly available tools for estimation of x-ray spectra in radiology and mammography. However, most of these models cannot be used directly for modeling microfocus x-ray sources due to differences in inherent filtration, energy range and/or anode material. For this reason the authors propose in this work a new model for the simulation of microfocus spectra based on existing models for mammography and radiology, modified to compensate for the effects of inherent filtration and energy range. Methods: The authors used the radiology and mammography versions of an existing empirical model [tungsten anode spectral model interpolating polynomials (TASMIP)] as the basis of the microfocus model. First, the authors estimated the inherent filtration included in the radiology model by comparing the shape of the spectra with spectra from the mammography model. Afterwards, the authors built a unified spectra dataset by combining both models and, finally, they estimated the parameters of the new version of TASMIP for microfocus sources by calibrating against experimental exposure data from a microfocus x-ray source. The model was validated by comparing estimated and experimental exposure and attenuation data for different attenuating materials and x-ray beam peak energy values, using two different x-ray tubes. Results: Inherent filtration for the radiology spectra from TASMIP was found to be equivalent to 1.68 mm Al, as compared to spectra obtained from the mammography model. To match the experimentally measured exposure data the combined dataset required to apply a negative filtration of about 0.21 mm Al and an anode roughness of 0.003 mm W. The validation of the model against real acquired data showed errors in exposure and attenuation in line with those reported for other models for radiology or mammography. Conclusions: A new version of the TASMIP model for the estimation of x-ray spectra in microfocus x-ray sources has been developed and validated experimentally. Similarly to other versions of TASMIP, the estimation of spectra is very simple, involving only the evaluation of polynomial expressions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of 2D and 3D gamma analyses

Purpose: As clinics begin to use 3D metrics for intensity-modulated radiation therapy (IMRT) quality assurance, it must be noted that these metrics will often produce results different from those produced by their 2D counterparts. 3D and 2D gamma analyses would be expected to produce different values, in part because of the different search space available. In the present investigation, the authors compared the results of 2D and 3D gamma analysis (where both datasets were generated in the same manner) for clinical treatment plans. Methods: Fifty IMRT plans were selected from the authors’ clinical database, and recalculated using Monte Carlo. Treatment planning system-calculated (“evaluated dose distributions”) and Monte Carlo-recalculated (“reference dose distributions”) dose distributions were compared using 2D and 3D gamma analysis. This analysis was performed using a variety of dose-difference (5%, 3%, 2%, and 1%) and distance-to-agreement (5, 3, 2, and 1 mm) acceptance criteria, low-dose thresholds (5%, 10%, and 15% of the prescription dose), and data grid sizes (1.0, 1.5, and 3.0 mm). Each comparison was evaluated to determine the average 2D and 3D gamma, lower 95th percentile gamma value, and percentage of pixels passing gamma. Results: The average gamma, lower 95th percentile gamma value, and percentage of passing pixels for each acceptance criterion demonstrated better agreement for 3D than for 2D analysis for every plan comparison. The average difference in the percentage of passing pixels between the 2D and 3D analyses with no low-dose threshold ranged from 0.9% to 2.1%. Similarly, using a low-dose threshold resulted in a difference between the mean 2D and 3D results, ranging from 0.8% to 1.5%. The authors observed no appreciable differences in gamma with changes in the data density (constant difference: 0.8% for 2D vs 3D). Conclusions: The authors found that 3D gamma analysis resulted in up to 2.9% more pixels passing than 2D analysis. It must be noted that clinical 2D versus 3D datasets may have additional differences—for example, if 2D measurements are made with a different dosimeter than 3D measurements. Factors such as inherent dosimeter differences may be an important additional consideration to the extra dimension of available data that was evaluated in this study.

61 RADIATION PROTECTION AND DOSIMETRY↗

Detection of Lung Contour with Closed Principal Curve and Machine Learning

Radiation therapy plays an essential role in the treatment of cancer. In radiation therapy, the ideal radiation doses are delivered to the observed tumor while not affecting neighboring normal tissues. In three-dimensional computed tomography (3D-CT) scans, the contours of tumors and organs-at-risk (OARs) are often manually delineated by radiologists. The task is complicated and time-consuming, and the manually delineated results will be variable from different radiologists. We propose a semi-supervised contour detection algorithm, which firstly uses a few points of region of interest (ROI) as an approximate initialization. Then the data sequences are achieved by the closed polygonal line (CPL) algorithm, where the data sequences consist of the ordered projection indexes and the corresponding initial points. Finally, the smooth lung contour can be obtained, when the data sequences are trained by the backpropagation neural network model (BNNM). We use the private clinical dataset and the public Lung Image Database Consortium and Image Database Resource Initiative (LIDC-IDRI) dataset to measure the accuracy of the presented method, respectively. To the private dataset, experimental results on the initial points which are as low as 15% of the manually delineated points show that the Dice coefficient reaches up to 0.95 and the global error is as low as 1.47 × 10{sup −2}. The performance of the proposed algorithm is also better than the cubic spline interpolation (CSI) algorithm. While on the public LIDC-IDRI dataset, our method achieves superior segmentation performance with average Dice of 0.83.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cosmological aspects of a hyperbolic solution in f(R,T) gravity

This article deals with a cosmological scenario in f(R,T) gravity for a flat FLRW model of the universe. We consider the f(R,T) function as f(R)+f(T) which starts with a quadratic correction of the geometric term f(R) having structure f(R)=R+αR{sup 2}, and a linear matter term f(T)=2λT. To achieve the solution of the gravitational field equations in the f(R,T) formalism, we take the form of a geometrical parameter, i.e. scale factor a(t)=sinh{sup (1/n)}(βt) (Chawla et al., 2013), where β and n are model parameters. An eternal acceleration can be predicted by the model for 0<n<1, while the cosmic transition from the early decelerated phase to the present accelerated epoch can be anticipated for n≥1. The obtained model facilitates the formation of structure in the Universe according to the Jeans instability condition as our model transits from radiation dominated era to matter dominated era. We study the varying role of the equation of state parameter ω. We analyze our model by studying the behavior of the scalar field and discuss the energy conditions on our achieved solution. We examine the validity of our model via Jerk parameter, Om diagnostic, Velocity of sound and Statefinder diagnostic tools. We investigate the constraints on the model parameter n and H{sub 0} (Hubble constant) using some observational datasets: SNeIa dataset, H(z) (Hubble parameter) dataset, BAO (Baryon Acoustic Oscillation data) and their combinations as joint observational datasets H(z) + SNeIa and H(z) + SNeIa + BAO. It is testified that the present study is well consistent with these observations. We also perform some cosmological tests and a detailed discussion of the model.

79 ASTRONOMY AND ASTROPHYSICS↗

Impact of Schedule Duration on Head and Neck Radiotherapy: Accelerated Tumor Repopulation Versus Compensatory Mucosal Proliferation

Purpose: To determine how modelled maximum tumor control rates, achievable without exceeding mucositis tolerance (tcp{sub max-early}) vary with schedule duration for head and neck squamous cell carcinoma (HNSCC). Methods and materials: Using maximum-likelihood techniques, we have fitted a range of tcp models to two HNSCC datasets (Withers' and British Institute of Radiology [BIR]), characterizing the dependence of tcp on duration and equivalent dose in 2 Gy fractions (EQD{sub 2}). Models likely to best describe future data have been selected using the Akaike information criterion (AIC) and its quasi-AIC extension to overdispersed data. Setting EQD{sub 2}s in the selected tcp models to levels just tolerable for mucositis, we have plotted tcp{sub max-early} against schedule duration. Results: While BIR dataset tcp fits describe dose levels isoeffective for tumor control as rising significantly with schedule protraction, indicative of accelerated tumor repopulation, repopulation terms in fits to Withers' dataset do not reach significance after accounting for overdispersion of the data. The tcp{sub max-early} curves calculated from tcp fits to the overall Withers' and BIR datasets rise by 8% and 0-4%, respectively, between 20 and 50 days duration; likewise, tcp{sub max-early} curves calculated for stage-specific cohorts also generally rise slowly with increasing duration. However none of the increases in tcp{sub max-early} calculated from the overall or stage-specific fits reach significance. Conclusions: Local control rates modeled for treatments which lie just within mucosal tolerance rise slowly but insignificantly with increasing schedule length. This finding suggests that whereas useful gains may be made by accelerating unnecessarily slow schedules until they approach early reaction tolerance, little is achieved by shortening schedules further while reducing doses to remain within mucosal tolerance, an approach that may slightly worsen outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A rotational and axial motion system load frame insert for in situ high energy x-ray studies

High energy x-ray characterization methods hold great potential for gaining insight into the behavior of materials and providing comparison datasets for the validation and development of mesoscale modeling tools. A suite of techniques have been developed by the x-ray community for characterizing the 3D structure and micromechanical state of polycrystalline materials; however, combining these techniques with in situ mechanical testing under well characterized and controlled boundary conditions has been challenging due to experimental design requirements, which demand new high-precision hardware as well as access to high-energy x-ray beamlines. We describe the design and performance of a load frame insert with a rotational and axial motion system that has been developed to meet these requirements. An example dataset from a deforming titanium alloy demonstrates the new capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing the cosmic distance duality relation using time delay lenses

The construction of the cosmic distance-duality relation (CDDR) has been widely studied. However, its consistency with various new observables remains a topic of interest. We present a new way to constrain the CDDR η( z ) using different dynamic and geometric properties of strong gravitational lenses (SGL) along with SNe Ia observations. We use a sample of 102 SGL with the measurement of corresponding velocity dispersion σ{sub 0} and Einstein radius θ {sub E} . In addition, we also use a dataset of 12 two image lensing systems containing the measure of time delay Δ t between source images. Jointly these two datasets give us the angular diameter distance D {sub A} {sub ol} of the lens. Further, for luminosity distance, we use the 740 observations from JLA compilation of SNe Ia. To study the combined behavior of these datasets we use a model independent method, Gaussian Process (GP). We also check the efficiency of GP by applying it on simulated datasets, which are generated in a phenomenological way by using realistic cosmological error bars. Finally, we conclude that the combined bounds from the SGL and SNe Ia observation do not favor any deviation of CDDR and are in concordance with the standard value (η=1) within 2σ confidence region, which further strengthens the theoretical acceptance of CDDR.

79 ASTRONOMY AND ASTROPHYSICS↗

Multiperspective Automotive Labeling

Supervised machine learning techniques inherently rely on datasets to be trained. With image datasets traditionally being annotated by humans, many advancements in image annotation tools have been made to ensure creation of rich datasets with accurate labels. Nevertheless, users still find it challenging to create and use their own datasets with labels that reflect their problem domain. We propose a streamlined labeling process that aligns multiperspective images and allows a transition from a labeled perspective to other perspectives. The main goal of this work is to reduce the human effort required for labeling vehicle images under favorable conditions where the image perspectives are correlated and one or more perspectives are known. A case study is described and analyzed to show the effectiveness of the process, as well as constraints and limitations when applied to other cases.

training dataset, multiperspective images, supervi↗

The art and power of data imaging

Data imaging and visual data assessment are veritable gold mines in the scientist's quest to understand and accurately interpret numerical data. Graphical displays of various aspects of a dataset offer the analyst insight to the data that no mathematical computation or statistic can provide. It is difficult, at best, for even a skilled and observant statistician to understand the underlying structure of a dataset. Often, there is either too little data to get a good 'picture' of the structure that might be present or there is so much data that one cannot readily assimilate it. Of course, the latter problem (too much data) is, in reality, no problem at all given the abilities of modern computers and software systems to manage large amounts of data. Advances in computer technology and the advent of the global positioning satellite system have enabled scientists from many fields of endeavor to collect and view data in its spatial context. Visual images constructed from spatially referenced data reveal the inherent richness and structure in the data and lead to more informed conclusions. So powerful is data collected with spatial context that a relatively new branch of mathematical statistics, geo-spatial statistics, has emerged. Geo-spatial statistics seek to exploit this context rich data form to better understand the spatial and co-relationships that might exist, but would be otherwise hidden in tabular data or obscured with classic statistical approaches. This paper (and accompanying presentation) will show the power that visual data assessment possesses to understand radiological scanning data and to make confident and accurate decisions based on the data images. It will challenge the traditional mathematical concept of detection limits for scanning. It will demonstrate that more data, even if the individual datum comprising the dataset is of 'poorer quality' (i.e., has a larger uncertainty and, thus, a larger calculated minimum detection value), is significantly more powerful than a smaller dataset comprised of higher quality measurements. This presentation will cause the open-minded health physicist to rethink how they prescribe, collect, evaluate, and make decisions based upon radiological scan data. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantifying the margin sharpness of lesions on radiological images for content-based image retrieval

Purpose: To develop a method to quantify the margin sharpness of lesions on CT and to evaluate it in simulations and CT scans of liver and lung lesions. Methods: The authors computed two attributes of margin sharpness: the intensity difference between a lesion and its surroundings, and the sharpness of the intensity transition across the lesion boundary. These two attributes were extracted from sigmoid curves fitted along lines automatically drawn orthogonal to the lesion margin. The authors then represented the margin characteristics for each lesion by a feature vector containing histograms of these parameters. The authors created 100 simulated CT scans of lesions over a range of intensity difference and margin sharpness, and used the concordance correlation between the known parameter and the corresponding computed feature as a measure of performance. The authors also evaluated their method in 79 liver lesions (44 patients: 23 M, 21 F, mean age 61) and 58 lung nodules (57 patients: 24 M, 33 F, mean age 66). The methodology presented takes into consideration the boundary of the liver and lung during feature extraction in clinical images to ensure that the margin feature do not get contaminated by anatomy other than the normal organ surrounding the lesions. For evaluation in these clinical images, the authors created subjective independent reference standards for pairwise margin sharpness similarity in the liver and lung cohorts, and compared rank orderings of similarity used using our sharpness feature to that expected from the reference standards using mean normalized discounted cumulative gain (NDCG) over all query images. In addition, the authors compared their proposed feature with two existing techniques for lesion margin characterization using the simulated and clinical datasets. The authors also evaluated the robustness of their features against variations in delineation of the lesion margin by simulating five types of deformations of the lesion margin. Equivalence across deformations was assessed using Schuirmann's paired two one-sided tests. Results: In simulated images, the concordance correlation between measured gradient and actual gradient was 0.994. The mean (s.d.) and standard deviation NDCG score for the retrieval of K images, K = 5, 10, and 15, were 84% (8%), 85% (7%), and 85% (7%) for CT images containing liver lesions, and 82% (7%), 84% (6%), and 85% (4%) for CT images containing lung nodules, respectively. The authors' proposed method outperformed the two existing margin characterization methods in average NDCG scores over all K, by 1.5% and 3% in datasets containing liver lesion, and 4.5% and 5% in datasets containing lung nodules. Equivalence testing showed that the authors' feature is more robust across all margin deformations (p < 0.05) than the two existing methods for margin sharpness characterization in both simulated and clinical datasets. Conclusions: The authors have described a new image feature to quantify the margin sharpness of lesions. It has strong correlation with known margin sharpness in simulated images and in clinical CT images containing liver lesions and lung nodules. This image feature has excellent performance for retrieving images with similar margin characteristics, suggesting potential utility, in conjunction with other lesion features, for content-based image retrieval applications.

60 APPLIED LIFE SCIENCES↗

Dynamic keyhole: A novel method to improve MR images in the presence of respiratory motion for real-time MRI

Purpose: In this work, the authors present a novel magnetic resonance imaging reconstruction method to improve the quality of MR images in the presence of respiratory motion for real-time thoracic image-guided radiotherapy. Methods: This new reconstruction method is called dynamic keyhole and utilizes a library of previously acquired, peripheral k-space datasets from the same (or similar) respiratory state in conjunction with central k-space datasets acquired in real-time. Internal or external respiratory signals are utilized to sort, match, and combine the two separate peripheral and central k-space datasets with respect to respiratory displacement, thereby reducing acquisition time and improving image quality without respiratory-related artifacts. In this study, the dynamic keyhole, conventional keyhole, and zero-filling methods were compared to full k-space acquisition (ground truth) for 60 coronal datasets acquired from 15 healthy human subjects. Results: For the same image-quality difference from the ground-truth image, the dynamic keyhole method reused 79% of the prior peripheral phase-encoding lines, while the conventional keyhole reused 73% and zero-filling 63% (p-value < 0.0001), corresponding to faster acquisition speed of dynamic keyhole for real-time imaging applications. Conclusions: This study demonstrates that the dynamic keyhole method is a promising technique for clinical applications such as image-guided radiotherapy requiring real-time MR monitoring of the thoracic region. Based on the results from this study, the dynamic keyhole method could increase the temporal resolution by a factor of five compared with full k-space methods.

60 APPLIED LIFE SCIENCES↗

Deformable segmentation of 3D MR prostate images via distributed discriminative dictionary and ensemble learning

Purpose: Automatic prostate segmentation from MR images is an important task in various clinical applications such as prostate cancer staging and MR-guided radiotherapy planning. However, the large appearance and shape variations of the prostate in MR images make the segmentation problem difficult to solve. Traditional Active Shape/Appearance Model (ASM/AAM) has limited accuracy on this problem, since its basic assumption, i.e., both shape and appearance of the targeted organ follow Gaussian distributions, is invalid in prostate MR images. To this end, the authors propose a sparse dictionary learning method to model the image appearance in a nonparametric fashion and further integrate the appearance model into a deformable segmentation framework for prostate MR segmentation. Methods: To drive the deformable model for prostate segmentation, the authors propose nonparametric appearance and shape models. The nonparametric appearance model is based on a novel dictionary learning method, namely distributed discriminative dictionary (DDD) learning, which is able to capture fine distinctions in image appearance. To increase the differential power of traditional dictionary-based classification methods, the authors' DDD learning approach takes three strategies. First, two dictionaries for prostate and nonprostate tissues are built, respectively, using the discriminative features obtained from minimum redundancy maximum relevance feature selection. Second, linear discriminant analysis is employed as a linear classifier to boost the optimal separation between prostate and nonprostate tissues, based on the representation residuals from sparse representation. Third, to enhance the robustness of the authors' classification method, multiple local dictionaries are learned for local regions along the prostate boundary (each with small appearance variations), instead of learning one global classifier for the entire prostate. These discriminative dictionaries are located on different patches of the prostate surface and trained to adaptively capture the appearance in different prostate zones, thus achieving better local tissue differentiation. For each local region, multiple classifiers are trained based on the randomly selected samples and finally assembled by a specific fusion method. In addition to this nonparametric appearance model, a prostate shape model is learned from the shape statistics using a novel approach, sparse shape composition, which can model nonGaussian distributions of shape variation and regularize the 3D mesh deformation by constraining it within the observed shape subspace. Results: The proposed method has been evaluated on two datasets consisting of T2-weighted MR prostate images. For the first (internal) dataset, the classification effectiveness of the authors' improved dictionary learning has been validated by comparing it with three other variants of traditional dictionary learning methods. The experimental results show that the authors' method yields a Dice Ratio of 89.1% compared to the manual segmentation, which is more accurate than the three state-of-the-art MR prostate segmentation methods under comparison. For the second dataset, the MICCAI 2012 challenge dataset, the authors' proposed method yields a Dice Ratio of 87.4%, which also achieves better segmentation accuracy than other methods under comparison. Conclusions: A new magnetic resonance image prostate segmentation method is proposed based on the combination of deformable model and dictionary learning methods, which achieves more accurate segmentation performance on prostate T2 MR images.

60 APPLIED LIFE SCIENCES↗

Lung motion estimation using dynamic point shifting: An innovative model based on a robust point matching algorithm

Purpose: Image-guided radiotherapy is an advanced 4D radiotherapy technique that has been developed in recent years. However, respiratory motion causes significant uncertainties in image-guided radiotherapy procedures. To address these issues, an innovative lung motion estimation model based on a robust point matching is proposed in this paper. Methods: An innovative robust point matching algorithm using dynamic point shifting is proposed to estimate patient-specific lung motion during free breathing from 4D computed tomography data. The correspondence of the landmark points is determined from the Euclidean distance between the landmark points and the similarity between the local images that are centered at points at the same time. To ensure that the points in the source image correspond to the points in the target image during other phases, the virtual target points are first created and shifted based on the similarity between the local image centered at the source point and the local image centered at the virtual target point. Second, the target points are shifted by the constrained inverse function mapping the target points to the virtual target points. The source point set and shifted target point set are used to estimate the transformation function between the source image and target image. Results: The performances of the authors’ method are evaluated on two publicly available DIR-lab and POPI-model lung datasets. For computing target registration errors on 750 landmark points in six phases of the DIR-lab dataset and 37 landmark points in ten phases of the POPI-model dataset, the mean and standard deviation by the authors’ method are 1.11 and 1.11 mm, but they are 2.33 and 2.32 mm without considering image intensity, and 1.17 and 1.19 mm with sliding conditions. For the two phases of maximum inhalation and maximum exhalation in the DIR-lab dataset with 300 landmark points of each case, the mean and standard deviation of target registration errors on the 3000 landmark points of ten cases by the authors’ method are 1.21 and 1.04 mm. In the EMPIRE10 lung registration challenge, the authors’ method ranks 24 of 39. According to the index of the maximum shear stretch, the authors’ method is also efficient to describe the discontinuous motion at the lung boundaries. Conclusions: By establishing the correspondence of the landmark points in the source phase and the other target phases combining shape matching and image intensity matching together, the mismatching issue in the robust point matching algorithm is adequately addressed. The target registration errors are statistically reduced by shifting the virtual target points and target points. The authors’ method with consideration of sliding conditions can effectively estimate the discontinuous motion, and the estimated motion is natural. The primary limitation of the proposed method is that the temporal constraints of the trajectories of voxels are not introduced into the motion model. However, the proposed method provides satisfactory motion information, which results in precise tumor coverage by the radiation dose during radiotherapy.

60 APPLIED LIFE SCIENCES↗

3D liver segmentation using multiple region appearances and graph cuts

Purpose: Efficient and accurate 3D liver segmentations from contrast-enhanced computed tomography (CT) images play an important role in therapeutic strategies for hepatic diseases. However, inhomogeneous appearances, ambiguous boundaries, and large variance in shape often make it a challenging task. The existence of liver abnormalities poses further difficulty. Despite the significant intensity difference, liver tumors should be segmented as part of the liver. This study aims to address these challenges, especially when the target livers contain subregions with distinct appearances. Methods: The authors propose a novel multiregion-appearance based approach with graph cuts to delineate the liver surface. For livers with multiple subregions, a geodesic distance based appearance selection scheme is introduced to utilize proper appearance constraint for each subregion. A special case of the proposed method, which uses only one appearance constraint to segment the liver, is also presented. The segmentation process is modeled with energy functions incorporating both boundary and region information. Rather than a simple fixed combination, an adaptive balancing weight is introduced and learned from training sets. The proposed method only calls initialization inside the liver surface. No additional constraints from user interaction are utilized. Results: The proposed method was validated on 50 3D CT images from three datasets, i.e., Medical Image Computing and Computer Assisted Intervention (MICCAI) training and testing set, and local dataset. On MICCAI testing set, the proposed method achieved a total score of 83.4 ± 3.1, outperforming nonexpert manual segmentation (average score of 75.0). When applying their method to MICCAI training set and local dataset, it yielded a mean Dice similarity coefficient (DSC) of 97.7% ± 0.5% and 97.5% ± 0.4%, respectively. These results demonstrated the accuracy of the method when applied to different computed tomography (CT) datasets. In addition, user operator variability experiments showed its good reproducibility. Conclusions: A multiregion-appearance based method is proposed and evaluated to segment liver. This approach does not require prior model construction and so eliminates the burdens associated with model construction and matching. The proposed method provides comparable results with state-of-the-art methods. Validation results suggest that it may be suitable for the clinical use.

60 APPLIED LIFE SCIENCES↗

Fast automatic 3D liver segmentation based on a three-level AdaBoost-guided active shape model

Purpose: A robust, automatic, and rapid method for liver delineation is urgently needed for the diagnosis and treatment of liver disorders. Until now, the high variability in liver shape, local image artifacts, and the presence of tumors have complicated the development of automatic 3D liver segmentation. In this study, an automatic three-level AdaBoost-guided active shape model (ASM) is proposed for the segmentation of the liver based on enhanced computed tomography images in a robust and fast manner, with an emphasis on the detection of tumors. Methods: The AdaBoost voxel classifier and AdaBoost profile classifier were used to automatically guide three-level active shape modeling. In the first level of model initialization, fast automatic liver segmentation by an AdaBoost voxel classifier method is proposed. A shape model is then initialized by registration with the resulting rough segmentation. In the second level of active shape model fitting, a prior model based on the two-class AdaBoost profile classifier is proposed to identify the optimal surface. In the third level, a deformable simplex mesh with profile probability and curvature constraint as the external force is used to refine the shape fitting result. In total, three registration methods—3D similarity registration, probability atlas B-spline, and their proposed deformable closest point registration—are used to establish shape correspondence. Results: The proposed method was evaluated using three public challenge datasets: 3Dircadb1, SLIVER07, and Visceral Anatomy3. The results showed that our approach performs with promising efficiency, with an average of 35 s, and accuracy, with an average Dice similarity coefficient (DSC) of 0.94 ± 0.02, 0.96 ± 0.01, and 0.94 ± 0.02 for the 3Dircadb1, SLIVER07, and Anatomy3 training datasets, respectively. The DSC of the SLIVER07 testing and Anatomy3 unseen testing datasets were 0.964 and 0.933, respectively. Conclusions: The proposed automatic approach achieves robust, accurate, and fast liver segmentation for 3D CTce datasets. The AdaBoost voxel classifier can detect liver area quickly without errors and provides sufficient liver shape information for model initialization. The AdaBoost profile classifier achieves sufficient accuracy and greatly decreases segmentation time. These results show that the proposed segmentation method achieves a level of accuracy comparable to that of state-of-the-art automatic methods based on ASM.

60 APPLIED LIFE SCIENCES↗

SU-G-BRC-17: Using Generalized Mean for Equivalent Square Estimation

Purpose: Equivalent Square (ES) is a widely used concept in radiotherapy. It enables us to determine many important quantities for a rectangular treatment field, without measurement, based on the corresponding values from its ES field. In this study, we propose a Generalized Mean (GM) type ES formula and compare it with other established formulae using benchmark datasets. Methods: Our GM approach is expressed as ES=(w•fx^α+(1-w)•fy^α)^(1/α), where fx, fy, α, and w represent field sizes, power index, and a weighting factor, respectively. When α=−1 it reduces to well-known Sterling type ES formulae. In our study, α and w are determined through least-square-fitting. Akaike Information Criterion (AIC) was used to benchmark the performance of each formula. BJR (Supplement 17) ES field table for X-ray PDDs and open field output factor tables in Varian TrueBeam representative dataset were used for validation. Results: Switching from α=−1 to α=−1.25, a 20% reduction in standard deviation of residual error in ES estimation was achieved for the BJR dataset. The maximum relative residual error was reduced from ∼3% (in Sterling formula) or ∼2% (in Vadash/Bjarngard formula) down to ∼1% in GM formula for open fields of all energies and at rectangular field sizes from 3cm to 40cm in the Varian dataset. The improvement of the GM over the Sterling type ES formulae is particularly noticeable for very elongated rectangular fields with short width. AIC analysis confirmed the superior performance of the GM formula after taking into account the expanded parameter space. Conclusion: The GM significantly outperforms Sterling type formulae at slightly increased computational cost. The GM calculation may nullify the requirement of data measurement for many rectangular fields and hence shorten the Linac commissioning process. Improved dose calculation accuracy is also expected by adopting the GM formula into treatment planning and secondary MU check systems.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP3-01: A Method to Quantify Lung SBRT Target Localization Accuracy Based On Digitally Reconstructed Fluoroscopy

Purpose: To develop a methodology based on digitally-reconstructed-fluoroscopy (DRF) to quantitatively assess target localization accuracy of lung SBRT, and to evaluate using both a dynamic digital phantom and a patient dataset. Methods: For each treatment field, a 10-phase DRF is generated based on the planning 4DCT. Each frame is pre-processed with a morphological top-hat filter, and corresponding beam apertures are projected to each detector plane. A template-matching algorithm based on cross-correlation is used to detect the tumor location in each frame. Tumor motion relative beam aperture is extracted in the superior-inferior direction based on each frame’s impulse response to the template, and the mean tumor position (MTP) is calculated as the average tumor displacement. The DRF template coordinates are then transferred to the corresponding MV-cine dataset, which is retrospectively filtered as above. The treatment MTP is calculated within each field’s projection space, relative to the DRF-defined template. The field’s localization error is defined as the difference between the DRF-derived-MTP (planning) and the MV-cine-derived-MTP (delivery). A dynamic digital phantom was used to assess the algorithm’s ability to detect intra-fractional changes in patient alignment, by simulating different spatial variations in the MV-cine and calculating the corresponding change in MTP. Inter-and-intra-fractional variation, IGRT accuracy, and filtering effects were investigated on a patient dataset. Results: Phantom results demonstrated a high accuracy in detecting both translational and rotational variation. The lowest localization error of the patient dataset was achieved at each fraction’s first field (mean=0.38mm), with Fx3 demonstrating a particularly strong correlation between intra-fractional motion-caused localization error and treatment progress. Filtering significantly improved tracking visibility in both the DRF and MV-cine images. Conclusion: We have developed and evaluated a methodology to quantify lung SBRT target localization accuracy based on digitally-reconstructed-fluoroscopy. Our approach may be useful in potentially reducing treatment margins to optimize lung SBRT outcomes. R01-184173.

60 APPLIED LIFE SCIENCES↗