Search NASA⌕ Search

SEARCH · Search NASA

Results for “Design Science”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Prototype muon detectors for the AMIGA component of the Pierre Auger Observatory

AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory to extend its range of detection and to directly measure the muon content of the particle showers. It consists of an infill of surface water-Cherenkov detectors accompanied by buried scintillator detectors used for muon counting. The main objectives of the AMIGA engineering array, referred to as the Unitary Cell, are to identify and resolve all engineering issues as well as to understand the muon-number counting uncertainties related to the design of the detector. The mechanical design, fabrication and deployment processes of the muon counters of the Unitary Cell are described in this document. These muon counters modules comprise sealed PVC casings containing plastic scintillation bars, wavelength-shifter optical fibers, 64 pixel photomultiplier tubes, and acquisition electronics. The modules are buried approximately 2.25 m below ground level in order to minimize contamination from electromagnetic shower particles. The mechanical setup, which allows access to the electronics for maintenance, is also described in addition to tests of the modules' response and integrity. As a result, the completed Unitary Cell has measured a number of air showers of which a first analysis of a sample event is included here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Target Housing Material Options

With gas cooling, heat transfer coefficients are low compared to water. The benefit of gas from a heat transfer point of view is that there is really no upper temperature limit for the coolant, as compared to water, which is limited ultimately by the critical point, and in practice the critical heat flux. In our case with parallel flow channels, water is limited to even lower operating limits by nucleate boiling. So gas can get as hot as the containment material will allow, but to get the density and heat transfer up to something reasonable, we must also increase pressure, thus increasing stress on the containment, namely the front and back faces. We are designing to ASME BPVC, which, for most materials allows a maximum stress of UTS/3. So we want the highest possible UTS. For reference, the front face stress in the 12 mm target at 300 psi was about 90 MPa. The inconel 718 allowable stress at 900°C is 1/3 of 517 or 172 MPa. So we are in a very safe place, but the uTS is dropping rapidly with temperature above 900°C. As we increase target diameter, the challenge will be to keep the stress down. We are probably looking at keeping the allowable at or above the present value, and at as high a temperature as possible.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Construction of an unyielding target for large horizontal impacts.

Sandia National Laboratories has constructed an unyielding target at the end of its 2000-foot rocket sled track. This target is made up of approximately 5 million pounds of concrete, an embedded steel load spreading structure, and a steel armor plate face that varies from 10 inches thick at the center to 4 inches thick at the left and right edges. The target/track combination will allow horizontal impacts at regulatory speeds of very large objects, such as a full-scale rail cask, or high-speed impacts of smaller packages. The load-spreading mechanism in the target is based upon the proven design that has been in use for over 20 years at Sandia's aerial cable facility. That target, with a weight of 2 million pounds, has successfully withstood impact forces of up to 25 million pounds. It is expected that the new target will be capable of withstanding impact forces of more than 70 million pounds. During construction various instrumentation was placed in the target so that the response of the target during severe impacts can be monitored. This paper will discuss the construction of the target and provide insights on the testing capabilities at the sled track with this new target.

33 ADVANCED PROPULSION SYSTEMS↗

Improving the reliability of the jpHMM recombination prediction in HIV

Accurate classification of HIV and the identification of recombinants, including precise breakpoint definitions, is of crucial importance for epidemiological monitoring and the design of potential drugs. Recently we developed jpHMM, a new method to detect recombinations in HIV-l genomes. jpHMM predicts phylogenetic recombination breakpoints in a query sequence and assigns to each segment of the sequence one of the major HIV-l subtypes. For the user the reliability of the predicted breakpoint positions and parental subtypes is most important. For this reason we extended the output of jpHMM to include the information on regions where the model is 'uncertain' about the parental subtype and an interval estimate of the breakpoint. This information is determined using the posterior probabilities of the subtypes at each query sequence position.

59 BASIC BIOLOGICAL SCIENCES↗

Design and validation of a single-exposure passive neutron spectrometer (PNS) - 14417

This paper summarises the initial design and validation work of a novel neutron spectrometry technique based on gold foil activation at key locations within a single moderating polyethylene sphere. This Passive Neutron Spectrometer (PNS) consists of five removable columns which contain 52 gold foils in total, deployed over three axes. Response functions have been modeled using MCNP5, up to energies of 20 MeV. Validation irradiations have been performed at Valduc (on the Caliban assembly), the ASP 2.5 MeV source on site at AWE, and at the Low Scatter Facility at the National Physical Laboratory in Teddington (where both 565 keV monoenergetic and californium sources were used). Results indicate that the PNS is a viable neutron spectrometry technique. Unlike similar instruments (eg. Gomez-Ros), the PNS is designed to be directionally dependant with the aim of separately evaluating the scattered neutron component of an extended source. A great deal of work is required however to: first, confirm this application is feasible; and second, be able to develop it for use. As such, the scope of this paper is limited to validating the isotropic response for conventional measurement acquisition and unfolding using the PTB-written unfolding code, MAXED. Additional work to be conducted in the future includes an investigation into the inclusion of different activation foils, and irradiation by Godiva-IV at a point previously characterised by the AWE Bonner Sphere set, for comparison. (authors)

42 ENGINEERING↗

A compact and portable gamma-ray spectrometer (GRASP) for inertial confinement fusion and basic science experiments

A compact and portable gamma-ray spectrometer has been designed to diagnose different components of the inertial confinement fusion-relevant γ-ray spectrum with energies between ∼3.7–17.9 MeV. The system is designed to be as compact as possible for convenient transportation and fielding in diagnostic ports on the OMEGA laser, the National Ignition Facility, and other photon-source facilities. The system consists of a conversion foil for Compton scattering in front of four magnetic spectrometer “arms,” each covering a different energy range and constructed out of cylindrical permanent magnet Halbach arrays. Monte Carlo simulations have been used to optimize and assess the performance of the conversion foil, and COSY INFINITY ion-optical simulations have been used to optimize the spectrometer magnets. The performance of the design is assessed for a simulated direct-drive γ-ray spectrum. Spanning its total γ-ray energy bandwidth and using a 1.7 mm thick boron conversion foil, the system’s total energy resolution and efficiency are ∼15.8%–4.5% and 5.4 × 10−7–3.7 × 10−7e−/γ, respectively, with room for improvement. Spectral γ-ray measurements will provide guidance to the inertial confinement fusion program toward achieving high-energy gain relevant to inertial fusion energy and enable new measurement capabilities for basic discovery science.

Instruments & Instrumentation↗

Sustainable bioleaching of lithium-ion batteries for critical metal recovery: Process optimization through design of experiments and thermodynamic modeling

Recycling spent lithium-ion batteries (LIBs) could alleviate supply risks for critical metals and be less harmful to the environment compared to new production of metals from mining. Developing a cost-effective LIB bioleaching process could be a promising alternative to traditional energy-intensive recycling technologies. Here, this study aimed to optimize bioleaching conditions for maximum economic competitiveness through design of experiments using iterative response surface methodology (RSM), assisted by thermodynamic modeling. The optimal condition was identified as 2.5% pulp density in 75 mM gluconic acid biolixiviant at 55°C for 30 h which could recover 57%–84% of nickel, 71%–86% of cobalt, and 100% of lithium and manganese, yielding a 17%–26% net profit margin. The recommended pulp density and acid concentrations, together with the observed metal solubilization, were supported by thermodynamic modeling predictions. Our study demonstrated that combining RSM with thermodynamic simulations could be a powerful tool for optimizing bioleaching conditions.

60 APPLIED LIFE SCIENCES↗

High efficiency multichannel collimator for structural studies of liquids and low-Z materials at high pressures and temperatures

A high efficiency multichannel collimator (MCC) device has been developed at the high pressure beamline ID27 of the European Synchrotron Radiation Facility to drastically reduce the x-ray background from the sample environment in the Paris-Edinburgh press. The main technical difficulty, which resides in the minimum slits size achievable using the classical mono-bloc design, has been resolved using an original concept based on a set of independent slits. Then, a very small slit size of 50 {mu}m was manufactured resulting in a great improvement of the signal to background ratio. In addition, the transfer function of the MCC has been measured using the x-ray diffusion signal of a metal doped glass and efficiently applied to correct the raw data. The potential of this new device is illustrated in two challenging examples: iron-sulfur liquid structures and C{sub 60} polymerization process at high pressure and high temperature.

43 PARTICLE ACCELERATORS↗

A 30 mK, 13.5 T scanning tunneling microscope with two independent tips

We describe the design, construction, and performance of an ultra-low temperature, high-field scanning tunneling microscope (STM) with two independent tips. The STM is mounted on a dilution refrigerator and operates at a base temperature of 30 mK with magnetic fields of up to 13.5 T. We focus on the design of the two-tip STM head, as well as the sample transfer mechanism, which allows in situ transfer from an ultra high vacuum preparation chamber while the STM is at 1.5 K. Other design details such as the vibration isolation and rf-filtered wiring are also described. Their effectiveness is demonstrated via spectral current noise characteristics and the root mean square roughness of atomic resolution images. The high-field capability is shown by the magnetic field dependence of the superconducting gap of Cu{sub x}Bi{sub 2}Se{sub 3}. Finally, we present images and spectroscopy taken with superconducting Nb tips with the refrigerator at 35 mK that indicate that the effective temperature of our tips/sample is approximately 184 mK, corresponding to an energy resolution of 16 μeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Open-loop correction for an eddy current dominated beam-switching magnet

A beam-switching magnet and the pulsed power supply it requires have been developed for the Japan Proton Accelerator Research Complex. To switch bunched proton beams, the dipole magnetic field must reach its maximum value within 40 ms. In addition, the field flatness should be less than 5 × 10{sup −4} to guide each bunched beam to the designed orbit. From a magnetic field measurement by using a long search coil, it was found that an eddy current in the thick endplates and laminated core disturbs the rise of the magnetic field. The eddy current also deteriorates the field flatness over the required flat-top period. The measured field flatness was 5 × 10{sup −3}. By using a double-exponential equation to approximate the measured magnetic field, a compensation pattern for the eddy current was calculated. The integrated magnetic field was measured while using the newly developed open-loop compensation system. A field flatness of less than 5 × 10{sup −4}, which is an acceptable value, was achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Highly sensitive pseudo-differential ac-nanocalorimeter for the study of the glass transition

We present a nanocalorimeter designed for the measurement of the dynamic heat capacity of thin films. The microfabricated sensor, the thermal conditioning of the sensor, as well as the highly stable and low noise electronic chain allow measurements of the real and imaginary parts of the complex specific heat with a resolution Δ C/C of about 10{sup −5}. The performances of this quasi-differential nanocalorimeter were tested on a model of polymeric glass-former, the polyvinyl acetate (PVAc). The high stability and low noise of the device are essential for accurate studies on non-equilibrium slow relaxing systems such as glasses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active and machine learning-based approaches to rapidly enhance microbial chemical production

In order to make renewable fuels and chemicals from microbes, new methods are required to engineer microbes more intelligently. Computational approaches, to engineer strains for enhanced chemical production typically rely on detailed mechanistic models (e.g., kinetic/stoichiometric models of metabolism)—requiring many experimental datasets for their parameterization—while experimental methods may require screening large mutant libraries to explore the design space for the few mutants with desired behaviors. To address these limitations, we developed an active and machine learning approach (ActiveOpt) to intelligently guide experiments to arrive at an optimal phenotype with minimal measured datasets. In this study, ActiveOpt was applied to two separate case studies to evaluate its potential to increase valine yields and neurosporene productivity in Escherichia coli. In both the cases, ActiveOpt identified the best performing strain in fewer experiments than the case studies used. This work demonstrates that machine and active learning approaches have the potential to greatly facilitate metabolic engineering efforts to rapidly achieve its objectives.

60 APPLIED LIFE SCIENCES↗

Neutron and Ion Irradiation Studies on Advanced Steels Using the Nuclear Science User Facilities

For nuclear reactor structural materials, irradiation is capable of inducing a series of microstructural modifications, such as dislocation loops/network, selective elemental segregation and precipitation, voids and helium bubbles, leading to the degradation in structural materials' performance through irradiation hardening and embrittlement, swelling, irradiation creep, etc. Since radiation poses challenges for structural applications in nuclear reactors in multiple aspects and the underlying mechanisms are often interconnected, radiation effect studies need well-designed test matrix and proper characterization techniques. The Nuclear Science User Facilities (NSUF) offer extensive capabilities for studying radiation effects in nuclear fuels and structural materials. This research covers both neutron and ion irradiation studies carried out using a variety of instruments through the NSUF. The neutron irradiation ferritic ODS steel MA957 was accomplished utilizing the neutron irradiation capability of the Advanced Test Reactor (ATR) and the post-irradiation examination (PIE) capabilities of the Center for Advanced Energy Studies (CAES). The neutron-irradiated specimens were characterized using transmission electron microscopy (TEM) and atom probe tomography (APT). The in situ TEM ion irradiation study on austenitic stainless steel (SS) 316H was completed using the IVEM-Tandem facility at Argonne National Laboratory.

36 MATERIALS SCIENCE↗

DAKOTA (Design Analysis Kit for Optimization and Terascale) v.6.14

Sandia's Dakota software supports science and engineering transformation through advanced exploration of simulations. Specifically, Dakota manages and analyzes ensembles of simulations to provide broader and deeper perspective for analysts and decision makers. This enables them to: (1) enhance understanding of risk, (2) improve products, and (3) assess simulation credibility. In its simplest mode, Dakota can automate typical parameter variation studies through a generic interface to a computational model. Dakota also delivers advanced parametric analysis techniques enabling design exploration, optimization, model calibration, risk analysis, and quantification of margins and uncertainty with such models. It directly supports verification and validation activities. The algorithms implemented in Dakota aim to address challenges in performing these analyses with complex science and engineering models from desktop to high performance computers. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525 SAND2021-10468 O

Adams, BrianM.↗

DAKOTA (Design Analysis Kit for Optimization and Terascale) v.6.16

Sandia's Dakota software supports science and engineering transformation through advanced exploration of simulations. Specifically, Dakota manages and analyzes ensembles of simulations to provide broader and deeper perspective for analysts and decision makers. This enables them to: (1) enhance understanding of risk, (2) improve products, and (3) assess simulation credibility. In its simplest mode, Dakota can automate typical parameter variation studies through a generic interface to a computational model. Dakota also delivers advanced parametric analysis techniques enabling design exploration, optimization, model calibration, risk analysis, and quantification of margins and uncertainty with such models. It directly supports verification and validation activities. The algorithms implemented in Dakota aim to address challenges in performing these analyses with complex science and engineering models from desktop to high performance computers. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525 SAND2021-10468 O

Adams, BrianM.↗

Self-assembly and regulation of protein cages from pre-organised coiled-coil modules

Coiled-coil protein origami (CCPO) is a modular strategy for the de novo design of polypeptide nanostructures. CCPO folds are defined by the sequential order of concatenated orthogonal coiled-coil (CC) dimer-forming peptides, where a single-chain protein is programmed to fold into a polyhedral cage. Self-assembly of CC-based nanostructures from several chains, similarly as in DNA nanotechnology, could facilitate the design of more complex assemblies and the introduction of functionalities. Here, we show the design of a de novo triangular bipyramid fold comprising 18 CC-forming segments and define the strategy for the two-chain self-assembly of the bipyramidal cage from asymmetric and pseudo-symmetric pre-organised structural modules. In addition, by introducing a protease cleavage site and masking the interfacial CC-forming segments in the two-chain bipyramidal cage, we devise a proteolysis-mediated conformational switch. This strategy could be extended to other modular protein folds, facilitating the construction of dynamic multi-chain CC-based complexes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Broadband single-shot electron spectrometer for GeV-class laser-plasma-based accelerators

Laser-plasma-based accelerators can provide electrons over a broad energy range and/or with large momentum spread. The electron beam energy distribution can be controlled via accurate control of laser and plasma properties, and beams with energies ranging from {approx_equal}0.5 to 1000 MeV have been observed. Measuring these energy distributions in a single shot requires the use of a diagnostic with large momentum acceptance and, ideally, sufficient resolution to accurately measure narrow energy spread beams. Such a broadband single-shot electron magnetic spectrometer for GeV-class laser-plasma-based accelerators has been developed at Lawrence Berkeley National Laboratory. Detailed descriptions of the design concept and hardware are presented, as well as a performance evaluation of the spectrometer. The spectrometer covered electron beam energies raging from 0.01 to 1.1 GeV in a single shot, and enabled the simultaneous measurement of the laser properties at the exit of the accelerator through the use of a sufficiently large pole gap. Based on measured field maps and third-order transport analysis, a few percent-level resolution and determination of the absolute energy were achieved over the entire energy range. Laser-plasma-based accelerator experiments demonstrated the capability of the spectrometer as a diagnostic and its suitability for measuring broadband electron sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗