Enhancing Critical Infrastructure and Key Resources (CIKR) Level-0 Physical Process Security Using Field Device Distinct Native Attribute Features

Here, the need for improved Critical Infrastructure and Key Resource (CIKR) security is unquestioned and there has been minimal emphasis on Level-0 (PHY Process) improvements. Wired Signal Distinct Native Attribute (WS-DNA) Fingerprinting is investigated here as a non-intrusive PHY-based security augmentation to support an envisioned layered security strategy. Results are based on experimental response collections from Highway Addressable Remote Transducer (HART) Differential Pressure Transmitter (DPT) devices from three manufacturers (Yokogawa, Honeywell, Endress+Hauer) installed in an automated process control system. Device discrimination is assessed using Time Domain (TD) and Slope-Based FSK (SB-FSK) fingerprints input to Multiple Discriminant Analysis, Maximum Likelihood (MDA/ML) and Random Forest (RndF) classifiers. For 12 different classes (two devices per manufacturer at two distinct set points), both classifiers performed reliably and achieved an arbitrary performance benchmark of average cross-class percent correct of %C > 90%. The least challenging cross-manufacturer results included near-perfect %C ≈ 100%, while the more challenging like-model (serial number) discrimination results included 90%< %C < 100%, with TD Fingerprinting marginally outperforming SB-FSK Fingerprinting; SB-FSK benefits from having less stringent response alignment and registration requirements. The RndF classifier was most beneficial and enabled reliable selection of dimensionally reduced fingerprint subsets that minimize data storage and computational requirements. The RndF selected feature sets contained 15% of the full-dimensional feature sets and only suffered a worst case %CΔ = 3% to 4% performance degradation.

60 APPLIED LIFE SCIENCES↗

Device Voltage Stress from Ground Leakage Current in Medium-Voltage Solid-State Transformer

Grounding related issues are critical for safe and reliable operation of solid-state transformer (SST) in medium-voltage (MV) applications, e.g., solar photovoltaic and energy storage integration, date center, electric vehicle fast charging, etc. This article presents for the first time the issue of additional device voltage stress due to grounding-loop current in current-source SST, using the soft-switching solid-state transformer (S4T) as an example. The S4T features single-stage isolated AC-AC, AC-DC, or DC-DC conversion with full-range ZVS, derived from flyback converter or current-source converter (CSC). However, the flyback operation for CSC-based SST means that magnetizing current flows through the reverse-blocking devices on only one side of the medium-frequency transformer (MFT) at a time. Then, the voltages across the devices, especially those on the other side of the MFT, can be influenced by parasitic current. A parasitic model of a modular S4T (M-S4T) prototype is developed from direct measurements and datasheets. Using the developed parasitic model and equivalent circuits, the causes of the voltage stress are analyzed. A voltage-stress mitigation scheme of connecting additional grounding capacitors is proposed. Damping resistors are also installed to damp out the grounding-loop resonance. A robust parameter design of the proposed scheme is given. The existence of the voltage stress issue and the effectiveness of the proposed scheme are verified experimentally on an MV SiC M-S4T prototype with inherent parameter variations among the five modules in the prototype. Here, both single-module and stacked-module operation are demonstrated during steady state and dynamic conditions up to 4 kV peak.

42 ENGINEERING↗

Improved Double Pulse Test for Accurate Dynamic Characterization of Medium Voltage SiC Devices

This article presents an improved double pulse test (DPT) for accurate dynamic characterization of the medium voltage (MV) silicon carbide device. The difference between low voltage (LV) and MV DPT setup grounding is first introduced, which results in different measurement considerations. Then, parasitic capacitances in the DPT and their impact on the DPT are discussed considering different grounding points and device connections. Approaches are proposed to minimize the impact of parasitic capacitances on DPT results. In addition, the impact of switching V-I timing alignment on the testing results is discussed, compared to that in the LV DPT; a V-I alignment approach is introduced for the MV DPT. A 10 kV/20 A SiC mosfet -based DPT is taken as an example of the improved DPT, and test results show that it can minimize the impact from parasitic and improve the accuracy of the device switching loss estimation.

42 ENGINEERING↗

Bi-Level Volt-VAR Optimization to Coordinate Smart Inverters with Voltage Control Devices

Conservation voltage reduction (CVR) uses voltage control to reduce customer power demand and help improve the operational efficiency of the electric power distribution system. With the advent of advanced distribution management systems (ADMS), the underlying data and control-rich platform can be utilized to enable a centralized Volt-VAR optimization (VVO) scheme that includes smart inverter controls along with legacy voltage control devices such as voltage regulators and capacitor banks to ensure a maximum CVR benefit. The objective of this paper to present a VVO approach that controls system’s legacy voltage control devices and coordinates their operation with smart inverter control. An optimal power flow (OPF) formulation is proposed by developing linear and nonlinear power flow approximations for a three-phase unbalanced electric power distribution system. A bi-level VVO approach is proposed where, Level-1 optimizes the control of legacy devices and smart inverters using a linear approximate three-phase power flow. In Level-2, the control parameters for smart inverters are adjusted to obtain an optimal and feasible solution by solving the approximate nonlinear OPF model. Level-1 is modeled as a Mixed Integer Linear Program (MILP) while Level-2 as a Quadratically Constrained Quadratic Program (QCQP). The proposed approach is validated using IEEE test cases and the results demonstrate the applicability of the framework in achieving the CVR objective.

Jha, Rahul Ranjan↗

Switching Device-Cognizant Sequential Distribution System Restoration

This paper presents an optimization framework for sequential reconfiguration using an assortment of switching devices and repair process in distribution system restoration. Compared to existing studies, this paper considers types, capabilities and operational limits of different switching devices, making it applicable in practice. We develop a novel multi-phase method to find the optimal sequential operation of various switching devices and repair faulted areas. We consider circuit breakers, reclosers, sectionalizers, load breaker switches, and fuses. The switching operation problem is decomposed into two mixed-integer linear programming (MILP) subproblems. The first subproblem determines the optimal network topology and estimates the number of steps to reach that topology, while the second subproblem generates a sequence of switching operations to coordinate the switches. For repairing the faults, we design an MILP model that dispatches repair crews to clear faults and replace melted fuses. After clearing a fault, we update the topology of the network by generating a new sequence of switching operations, and the process continues until all faults are cleared. To improve the computational efficiency, a network reduction algorithm is developed to group line sections, such that only switchable sections are present in the reduced network. The proposed method is validated on the IEEE 123-bus and 8500-bus systems.

distribution system↗

Coordinated Use of Smart Inverters with Legacy Voltage Regulating Devices in Distribution Systems with High Distributed PV Penetration — Increase CVR Energy Savings

This paper studies the coordinated use of smart inverters with legacy voltage regulating devices to help increase the energy savings from conservation voltage reduction (CVR) in distribution systems with high photovoltaic penetration. Two voltage optimization algorithms are developed to evaluate the CVR benefit by considering two types of smart inverter functions: aggregated reactive power control and autonomous volt/VAR control. In each algorithm, smart inverters are coordinately controlled with the operation of legacy voltage regulating devices including load tap changers and capacitor banks. Both algorithms are tested on representative utility distribution system models. In conclusion, simulation results demonstrate that the proposed algorithms can achieve around 1.8-3.6% energy savings when only using legacy voltage regulating devices and an additional 0.3-0.9% when adding smart inverters.

14 SOLAR ENERGY↗

A Phenomenological Thermal Spray Wall Interaction Modeling Framework Applied to a High Temperature Ignition Assistant Device

Airborne compression ignition engines must operate with reliable ignition systems to achieve proper ignition at every cycle, particularly at high altitudes. Glow-plug-based ignition-assistant (IA) devices can provide the necessary energy to preheat the fuel and ensure ignitability of the fuel-air mixture. Ignitability of liquid sprays can be facilitated via direct impingement onto the hot IA surface, however this comes with adverse effects on the IA durability. Therefore, optimizing an IA’s design requires detailed understanding of the physics of fuel spray impingement of superheated surfaces. While spray impingement on relatively low wall temperatures has been extensively studied and appropriate numerical models have been proposed through the years, fundamental understanding of high-speed liquid spray impingement on superheated walls is still elusive. This work aims to formulate a phenomenological thermal spray-wall interaction framework for modeling the film-boiling-induced heat transfer, atomization, and dispersion of fuel spray droplets impinging onto a superheated IA device. A qualitative comparison of the new phenomenological model is performed against optical experiments from the literature of an F-24 fuel spray injected onto an IA device located 12 mm away from the injector tip. The temperature of the IA was set at 1400 K. The fuel injection pressure was 400 bar, while the ambient gas pressure and temperature were 30 bar and 800 K, respectively. The performance of the phenomenological model is evaluated in comparison with two other state-of-art models from the literature. A qualitative analysis of the different spray and fuel-air mixture characteristics is performed to outline the differences in the predictions offered by the new phenomenological model and the two state-of-art spray-wall interaction models.

droplet dispersion↗

Monitoring critical facilities by using advanced RF devices

The ability to monitor critical environment parameters of nuclear plants at all times, particularly during and after a disruptive accident, is vital for the safety of plant personnel, rescue and recovery crews, and the surrounding communities. Conventional hard-wired assets that depend on supplied power may be decimated as a result of such events, as witnessed in the Japanese Fukushima nuclear power plant in March 2011. Self-powered monitoring devices operating on a wireless platform, on the other hand, may survive such calamity and remain functional. The devices would be pre-positioned at strategic locations, particularly where the dangerous build-up of contamination and radiation may preclude subsequent manned entrance and surveillance. Equipped with sensors for β-γ radiation, neutrons, hydrogen gas, temperature, humidity, pressure, and water level, as well as with criticality alarms and imaging equipment for heat, video, and other capabilities, these devices can provide vital surveillance information for assessing the extent of plant damage, mandating responses (e.g., evacuation before impending hydrogen explosion), and enabling overall safe and efficient recovery in a disaster. A radio frequency identification (RFID)-based system - called ARG-US - may be modified and adapted for this task. Developed by Argonne for DOE, ARG-US (meaning 'watchful guardian') has been used successfully to monitor and track sensitive nuclear materials packages at DOE sites. It utilizes sensors in the tags to continuously monitor the state of health of the packaging and promptly disseminates alarms to authorized users when any of the preset sensor thresholds is violated. By adding plant-specific monitoring sensors to the already strong sensor suite and adopting modular hardware, firmware, and software subsystems that are tailored for specific subsystems of a plant, a Remote Area Modular Monitoring (RAMM) system, built on a wireless sensor network (WSN) platform, is being developed by Argonne National Laboratory. ARG-US RAMM, powered by on-board battery, can sustain extended autonomous surveillance operation during and following an incident. The benefits could be invaluable to such critical facilities as nuclear power plants, research and test reactors, fuel cycle manufacturing centers, spent-fuel dry-cask storage facilities, and other nuclear installations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

IoT Devices and Applications for Wire-Based Hybrid Manufacturing Machine Tools

Hybrid manufacturing machine tools have the potential to be a disruptive technology as they can leverage the benefits of both additive and subtractive manufacturing by incorporating both processes on the same machine while limiting the downsides of the individual processes. Since these machines use two very disparate manufacturing processes and hybrid manufacturing is an emerging technology, it will be useful to monitor data coming from the machine and apply it to improve the manufacturing process, the operation of the machine, and to integrate the machine into the larger digital framework of Industrial Internet of Things (IoT). The present work discusses IoT devices that would be beneficial to add to a hybrid machine tool as well as applications for those devices. The proposed methods discussed in this work have not been experimentally implemented on a hybrid machine tool and so there are no performance data available yet. The hybrid machine tool used as a basis to generate these IoT applications is the Mazak VC-500A/5x AM Hot Wire Deposition, which is a 5-axis machine tool incorporated with a wire feedstock 4kW laser deposition system. Methodologies and applications will be outlined for machine health and process monitoring. Other areas covered include process benchmarking, secure networking options for the proposed IoT framework, and hybrid process improvement. Limitations of these methods and future work for new sensor devices and application areas is also discussed.

Thien, Austen↗

Low-temperature atomic layer deposition of TiO{sub 2} thin layers for the processing of memristive devices

Atomic layer deposition (ALD) represents one of the most fundamental techniques capable of satisfying the strict technological requirements imposed by the rapidly evolving electronic components industry. The actual scaling trend is rapidly leading to the fabrication of nanoscaled devices able to overcome limits of the present microelectronic technology, of which the memristor is one of the principal candidates. Since their development in 2008, TiO{sub 2} thin film memristors have been identified as the future technology for resistive random access memories because of their numerous advantages in producing dense, low power-consuming, three-dimensional memory stacks. The typical features of ALD, such as self-limiting and conformal deposition without line-of-sight requirements, are strong assets for fabricating these nanosized devices. This work focuses on the realization of memristors based on low-temperature ALD TiO{sub 2} thin films. In this process, the oxide layer was directly grown on a polymeric photoresist, thus simplifying the fabrication procedure with a direct liftoff patterning instead of a complex dry etching process. The TiO{sub 2} thin films deposited in a temperature range of 120–230 °C were characterized via Raman spectroscopy and x-ray photoelectron spectroscopy, and electrical current–voltage measurements taken in voltage sweep mode were employed to confirm the existence of resistive switching behaviors typical of memristors. These measurements showed that these low-temperature devices exhibit an ON/OFF ratio comparable to that of a high-temperature memristor, thus exhibiting similar performances with respect to memory applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cryogenic optical beam steering for superconducting device calibration

We have developed a calibration system based on a micro-electromechanical systems (MEMS) mirror that is capable of delivering an optical beam over a wavelength range of 180 -- 2000 nm (0.62 -- 6.89 eV) in a sub-Kelvin environment. This portable, integrated system can steer the beam over a $\sim$3 cm $\times$ 3 cm area on the surface of any sensor with a precision of $\sim$100 $μ$m, enabling characterization of device response as a function of position. This fills a critical need in the landscape of calibration tools for sub-Kelvin devices, including those used for dark matter detection and quantum computing. These communities have a shared goal of understanding the impact of ionizing radiation on device performance, which can be pursued with our system. This paper describes the design of the first-generation calibration system and the results from successfully testing its performance at room temperature and 20 mK.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Laser-Damage-Resistant Photoalignment Layers for High-Peak-Power Liquid Crystal Device Applications

Large-aperture liquid crystal (LC) devices have been in continuous use since 1995 as polarization control devices in the 40-TW, 351-nm, 60-beam OMEGA Nd:glass laser system at the University of Rochester’s Laboratory for Laser Energetics. The feasibility of using a noncontacting alignment method for high-peak-power LC laser optics by irradiation of a linearly photopolymerizable polymer with polarized UV light was recently investigated. These materials were found to have surprisingly large laser-damage thresholds at 1054 nm, approaching that of bare fused silica (30 to 60 J/cm^2). Their remarkable laser-damage resistance and ease in scalability to large apertures of these photoalignment materials, along with the ability to produce multiple alignment states by photolithographic patterning, opens new doorways for their application in LC devices for optics, photonics, and high-peak-power laser applications.

cinnamate↗

Large-area low-temperature ultrananocrystaline diamond (UNCD) films and integration with CMOS devices for monolithically integrated diamond MEMD/NEMS-CMOS systems.

Because of exceptional mechanical, chemical, and tribological properties, diamond has a great potential to be used as a material for the development of high-performance MEMS and NEMS such as resonators and switches compatible with harsh environments, which involve mechanical motion and intermittent contact. Integration of such MEMS/NEMS devices with complementary metal oxide semiconductor (CMOS) microelectronics will provide a unique platform for CMOS-driven commercial MEMS/NEMS. The main hurdle to achieve diamond-CMOS integration is the relatively high substrate temperatures (600-800 C) required for depositing conventional diamond thin films, which are well above the CMOS operating thermal budget (400 C). Additionally, a materials integration strategy has to be developed to enable diamond-CMOS integration. Ultrananocrystalline diamond (UNCD), a novel material developed in thin film form at Argonne, is currently the only microwave plasma chemical vapor deposition (MPCVD) grown diamond film that can be grown at 400 C, and still retain exceptional mechanical, chemical, and tribological properties comparable to that of single crystal diamond. We have developed a process based on MPCVD to synthesize UNCD films on up to 200 mm in diameter CMOS wafers, which will open new avenues for the fabrication of monolithically integrated CMOS-driven MEMS/NEMS based on UNCD. UNCD films were grown successfully on individual Si-based CMOS chips and on 200 mm CMOS wafers at 400 C in a MPCVD system, using Ar-rich/CH4 gas mixture. The CMOS devices on the wafers were characterized before and after UNCD deposition. All devices were performing to specifications with very small degradation after UNCD deposition and processing. A threshold voltage degradation in the range of 0.08-0.44V and transconductance degradation in the range of 1.5-9% were observed.

36 MATERIALS SCIENCE↗

Investigation of the spatial resolution of an online dose verification device

Purpose: The aim of this work is to characterize a new online dose verification device, COMPASS transmission detector array (IBA Dosimetry, Schwarzenbruck, Germany). The array is composed of 1600 cylindrical ionization chambers of 3.8 mm diameter, separated by 6.5 mm center-to-center spacing, in a 40 x 40 arrangement. Methods: The line spread function (LSF) of a single ion chamber in the detector was measured with a narrow slit collimator for a 6 MV photon beam. The 0.25 x 10 mm{sup 2} slit was formed by two machined lead blocks. The LSF was obtained by laterally translating the detector in 0.25 mm steps underneath the slit over a range of 24 mm and taking a measurement at each step. This measurement was validated with Monte Carlo simulation using BEAMnrc and DOSXYZnrc. The presampling modulation transfer function (MTF), the Fourier transform of the line spread function, was determined and compared to calculated (Monte Carlo and analytical) MTFs. Two head-and-neck intensity modulated radiation therapy (IMRT) fields were measured using the device and were used to validate the LSF measurement. These fields were simulated with the BEAMnrc Monte Carlo model, and the Monte Carlo generated incident fluence was convolved with the 2D detector response function (derived from the measured LSF) to obtain calculated dose. The measured and calculated dose distributions were then quantitatively compared using {chi}-comparison criteria of 3% dose difference and 3 mm distance-to-agreement for in-field points (defined as those above the 10% maximum dose threshold). Results: The full width at half-maximum (FWHM) of the measured detector response for a single chamber is 4.3 mm, which is comparable to the chamber diameter of 3.8 mm. The pre-sampling MTF was calculated, and the resolution of one chamber was estimated as 0.25 lp/mm from the first zero crossing. For both examined IMRT fields, the {chi}-comparison between measured and calculated data show good agreement with 95.1% and 96.3% of in-field points below {chi} of 1.0 for fields 1 and 2, respectively (with an average {chi} of 0.29 for IMRT field 1 and 0.24 for IMRT field 2). Conclusions: The LSF for a new novel online detector has been measured at 6 MV using a narrow slit technique, and this measurement has been validated by Monte Carlo simulation. The detector response function derived from line spread function has been applied to recover measured IMRT fields. The results have shown that the device measures IMRT fields accurately within acceptable tolerance.

61 RADIATION PROTECTION AND DOSIMETRY↗

Parallel transmit excitation at 1.5 T based on the minimization of a driving function for device heating

Purpose: To provide a rapid method to reduce the radiofrequency (RF) E-field coupling and consequent heating in long conductors in an interventional MRI (iMRI) setup. Methods: A driving function for device heating (W) was defined as the integration of the E-field along the direction of the wire and calculated through a quasistatic approximation. Based on this function, the phases of four independently controlled transmit channels were dynamically changed in a 1.5 T MRI scanner. During the different excitation configurations, the RF induced heating in a nitinol wire immersed in a saline phantom was measured by fiber-optic temperature sensing. Additionally, a minimization of W as a function of phase and amplitude values of the different channels and constrained by the homogeneity of the RF excitation field (B{sub 1}) over a region of interest was proposed and its results tested on the benchtop. To analyze the validity of the proposed method, using a model of the array and phantom setup tested in the scanner, RF fields and SAR maps were calculated through finite-difference time-domain (FDTD) simulations. In addition to phantom experiments, RF induced heating of an active guidewire inserted in a swine was also evaluated. Results: In the phantom experiment, heating at the tip of the device was reduced by 92% when replacing the body coil by an optimized parallel transmit excitation with same nominal flip angle. In the benchtop, up to 90% heating reduction was measured when implementing the constrained minimization algorithm with the additional degree of freedom given by independent amplitude control. The computation of the optimum phase and amplitude values was executed in just 12 s using a standard CPU. The results of the FDTD simulations showed similar trend of the local SAR at the tip of the wire and measured temperature as well as to a quadratic function of W, confirming the validity of the quasistatic approach for the presented problem at 64 MHz. Imaging and heating reduction of the guidewire were successfully performed in vivo with the proposed hardware and phase control. Conclusions: Phantom and in vivo data demonstrated that additional degrees of freedom in a parallel transmission system can be used to control RF induced heating in long conductors. A novel constrained optimization approach to reduce device heating was also presented that can be run in just few seconds and therefore could be added to an iMRI protocol to improve RF safety.

60 APPLIED LIFE SCIENCES↗

TU-AB-201-10: Novel Conformal Skin Brachytherapy Device

Purpose: A novel conformal skin brachytherapy (CSBT) device was developed to provide patient specific treatment for small inoperable lesions and irregular surfaces that are not good candidates for electron external beam, e.g. eyelids, nose, lips, ears, etc. Methods: A prototype was built and tested using radioactive seeds spaced by 1.5 mm attached to a 3D printed template. Seeds were allowed to move independently at treatment surface to conform to target geometry. Beta-emitter Praseodymium-142 (half-life: 19.12 h, average beta energy: 809 keV) and Iodine-125 Model 6711 (half-life: 59.4 days, average gamma energy: 28 keV) seeds were used to test the feasibility of the device in solid water phantom for different prescription depths and surface areas. Percent depth doses and dose profiles were analyzed. MCNPX2.6 Monte Carlo Simulation and Gafchromic EBT3 film measurements were performed for a single Pr-142 seed. Treatment with nineteen I-125 seeds was planned in BrachyVision and measured experimentally for a total dose of 500 cGy at 5.0 mm depth. Results: For a single Pr-142 seed, dose was 500.0 cGy at surface and 17.4 cGy at 5.00 mm. BrachyVision planned and film doses for I-125 seed matrix were 500 cGy and 473.5 cGy at 5 mm depth and 171.0 cGy and 201.0 cGy at 10 mm depth. Total covered surface area for Pr-142 and I-125 were 2.35 mm{sup 2} and 88.24 mm{sup 2} respectively. Profile dose fall-off showed to be very conformal to contact area with 50% of the total surface dose from a single Pr-142 and array of I-125 seeds being deposited at 0.72 mm and 0.65 mm respectively from the central axis. Conclusion: CSBT device provides a high conformal dose to small surfaces. BrachyVision can be used to predict clinical dose distributions for multiple seeds matrix. Different radioactive seeds can be used to suit prescription depth and treatment area.

60 APPLIED LIFE SCIENCES↗

TU-D-201-00: Use of End-Of-Life Brachytherapy Devices

Brachytherapy devices and software are designed to last for a certain period of time. Due to a number of considerations, such as material factors, wear-and-tear, backwards compatibility, and others, they all reach a date when they are no longer supported by the manufacturer. Most of these products have a limited duration for their use, and the information is provided to the user at time of purchase. Because of issues or concerns determined by the manufacturer, certain products are retired sooner than the anticipated date, and the user is immediately notified. In these situations, the institution is facing some difficult choices: remove these products from the clinic or perform tests and continue their usage. Both of these choices come with a financial burden: replacing the product or assuming a potential medicolegal liability. This session will provide attendees with the knowledge and tools to make better decisions when facing these issues. Learning Objectives: Understand the meaning of “end-of-life or “life expectancy” for brachytherapy devices and software Review items (devices and software) affected by “end-of-life” restrictions Learn how to effectively formulate “end-of-life” policies at your institution Learn about possible implications of “end-of-life” policy Review other possible approaches to “end-of-life” issue.

60 APPLIED LIFE SCIENCES↗

TU-D-201-01: Definition and Purpose of End-Of-Life for Brachytherapy Devices and Software

Brachytherapy devices and software are designed to last for a certain period of time. Due to a number of considerations, such as material factors, wear-and-tear, backwards compatibility, and others, they all reach a date when they are no longer supported by the manufacturer. Most of these products have a limited duration for their use, and the information is provided to the user at time of purchase. Because of issues or concerns determined by the manufacturer, certain products are retired sooner than the anticipated date, and the user is immediately notified. In these situations, the institution is facing some difficult choices: remove these products from the clinic or perform tests and continue their usage. Both of these choices come with a financial burden: replacing the product or assuming a potential medicolegal liability. This session will provide attendees with the knowledge and tools to make better decisions when facing these issues. Learning Objectives: Understand the meaning of “end-of-life or “life expectancy” for brachytherapy devices and software Review items (devices and software) affected by “end-of-life” restrictions Learn how to effectively formulate “end-of-life” policies at your institution Learn about possible implications of “end-of-life” policy Review other possible approaches to “end-of-life” issue.

60 APPLIED LIFE SCIENCES↗