Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Optimizing Transportation Networks for E-Waste Reverse Logistics: A Multi-Modal Cost Allocation and Pricing Strategy

The exponential growth of electronic waste (e-waste) poses critical challenges for sustainable reverse logistics and transportation network optimization. This study develops a dual-channel transportation framework for e-waste logistics that integrates dynamic freight pricing, cost allocation mechanisms, and game-theoretic coordination. The model captures interactions between centralized hubs and distributed processing networks, accounting for freight rate elasticity, volume allocation, and capacity constraints. Using Stackelberg game theory and cost-sharing strategies, the framework optimizes transportation efficiency and profit distribution across logistics channels. Numerical simulations show that the dual-channel structure increases centralized hub profit by 226.8% compared to baseline single-channel operations, while boosting total transported volume by 1.2% and nearly doubling freight collector profit under cost-sharing. Scenario analyses across regional infrastructures reveal that network density, policy incentives, and logistics costs shape routing efficiency and profit allocation. These findings suggest that coordinated strategies combining dynamic pricing, targeted infrastructure investment, and strategic cost allocation are needed to design efficient, resilient, and regionally adaptable e-waste transportation systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Plan averaging for multicriteria navigation of sliding window IMRT and VMAT

Purpose: To describe a method for combining sliding window plans [intensity modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT)] for use in treatment plan averaging, which is needed for Pareto surface navigation based multicriteria treatment planning. Methods: The authors show that by taking an appropriately defined average of leaf trajectories of sliding window plans, the authors obtain a sliding window plan whose fluence map is the exact average of the fluence maps corresponding to the initial plans. In the case of static-beam IMRT, this also implies that the dose distribution of the averaged plan is the exact dosimetric average of the initial plans. In VMAT delivery, the dose distribution of the averaged plan is a close approximation of the dosimetric average of the initial plans. Results: The authors demonstrate the method on three Pareto optimal VMAT plans created for a demanding paraspinal case, where the tumor surrounds the spinal cord. The results show that the leaf averaged plans yield dose distributions that approximate the dosimetric averages of the precomputed Pareto optimal plans well. Conclusions: The proposed method enables the navigation of deliverable Pareto optimal plans directly, i.e., interactive multicriteria exploration of deliverable sliding window IMRT and VMAT plans, eliminating the need for a sequencing step after navigation and hence the dose degradation that is caused by such a sequencing step.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-AB-BRB-00: Research Opportunities with Digital Linear Accelerators

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-01: Trajectory Modulated Arc Therapy: Application to Partial Breast Irradiation

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-02: ET-Reloaded

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-03: 4n Radiotherapy

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRB-05: Using a Research Real-Time Control Interface to Go Beyond Dynamic MLC Tracking

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

An Optimized Parameterization of Sub‐Grid Scale Advection for Convection Permitting Models

Convection‐permitting models (CPMs) explicitly resolve deep convection yet under‐resolve the organized lateral exchanges among drafts and their environment that control entrainment/detrainment, precipitation efficiency, and mesoscale structure. In this work, we introduce the Optimized Advection Scheme (OAS), which introduces a small rotation of the Cartesian frame of reference for the horizontal winds relative to other variables used in advection that induces cross‐gradient transport to mimic under‐resolved convective mixing. The rotation angle is selected to minimize the Kullback–Leibler divergence between the simulated and satellite observed precipitation intensity distributions, yielding a physically consistent perturbation that is computationally inexpensive and portable. Optimized Advection Scheme is implemented in WRF and evaluated over Amazon (April 2014). It shifts precipitation–precipitable‐water joint distributions toward lighter rain, reduces overly intense rates, and improves mesoscale convective system (MCS) lifetime and propagation. Mechanistically, the added cross‐gradient transport promotes convective detrainment and environmental mixing, which cools and moistens the mid‐troposphere, weakens downward momentum transport, alleviates excessive downwelling shortwave biases, and warms the surface temperature. The optimized rotation angle yields comparable improvements at 4‐km and 1‐km grid spacing, demonstrating resolution‐independent benefits across the CPM gray zone. By targeting the dynamical root of under‐mixed convective circulations, rather than tuning model microphysics or closures, OAS delivers robust, scale‐aware improvements in precipitation statistics, cloud vertical structure, and characteristics of MCS (MCSs), offering a practical pathway to more reliable CPM simulations for weather and climate applications.

CPM↗

TH-AB-BRB-04: Quality Assurance for Advanced Digital Linac Implementations

Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.

60 APPLIED LIFE SCIENCES↗

Variations in Linear Energy Transfer Within Clinical Proton Therapy Fields and the Potential for Biological Treatment Planning

Purpose: To calculate the linear energy transfer (LET) distributions in patients undergoing proton therapy. These distributions can be used to identify areas of elevated or diminished biological effect. The location of such areas might be influenced in intensity-modulated proton therapy (IMPT) optimization. Methods and Materials: Because Monte Carlo studies to investigate the LET distribution in patients have not been undertaken so far, the code is first validated with simulations in water. The code was used in five patients, for each of them three planning and delivery techniques were simulated: passive scattering, three-dimensional modulation IMPT (3D-IMPT), and distal edge tracking IMPT (DET-IMPT). Results: The inclusion of secondary particles led to significant differences compared with analytical techniques. In addition, passive scattering and 3D-IMPT led to largely comparable LET distributions, whereas the DET-IMPT plans resulted in considerably increased LET values in normal tissues and critical structures. In the brainstem, dose-averaged LET values exceeding 5 keV/{mu}m were observed in areas with significant dose (>70% of prescribed dose). In noncritical normal tissues, even values >8 keV/{mu}m occurred. Conclusion: This work demonstrates that active scanning offers the possibility of influencing the distribution of dose-averaged LET (i.e., the biological effect) without significantly altering the distribution of physical dose. On the basis of this finding, we propose a method to alter deliberately the LET distribution of a treatment plan in such a manner that the LET is maximized within certain target areas and minimized in normal tissues, while maintaining the prescribed target dose and dose constraints for organs at risk.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Static vs stochastic optimization: A case study of FTSE Bursa Malaysia sectorial indices

Traditional portfolio optimization methods in the likes of Markowitz' mean-variance model and semi-variance model utilize static expected return and volatility risk from historical data to generate an optimal portfolio. The optimal portfolio may not truly be optimal in reality due to the fact that maximum and minimum values from the data may largely influence the expected return and volatility risk values. This paper considers distributions of assets' return and volatility risk to determine a more realistic optimized portfolio. For illustration purposes, the sectorial indices data in FTSE Bursa Malaysia is employed. The results show that stochastic optimization provides more stable information ratio.

97 MATHEMATICS AND COMPUTING↗

Apparatus and method for providing workload distribution of threads among multiple compute units

In some examples, thermal aware optimization logic determines a characteristic (e.g., a workload or type) of a wavefront (e.g., multiple threads). For example, the characteristic indicates whether the wavefront is compute intensive, memory intensive, mixed, and/or another type of wavefront. The thermal aware optimization logic determines temperature information for one or more compute units (CUs) in one or more processing cores. The temperature information includes predictive thermal information indicating expected temperatures corresponding to the one or more CUs and historical thermal information indicating current or past thermal temperatures of at least a portion of a graphics processing unit (GPU). The logic selects the one or more compute units to process the plurality of threads based on the determined characteristic and the temperature information. The logic provides instructions to the selected subset of the plurality of CUs to execute the wavefront.

Rao, Karthik↗

Apparatus and method for providing workload distribution of threads among multiple compute units

In some examples, thermal aware optimization logic determines a characteristic (e.g., a workload or type) of a wavefront (e.g., multiple threads). For example, the characteristic indicates whether the wavefront is compute intensive, memory intensive, mixed, and/or another type of wavefront. The thermal aware optimization logic determines temperature information for one or more compute units (CUs) in one or more processing cores. The temperature information includes predictive thermal information indicating expected temperatures corresponding to the one or more CUs and historical thermal information indicating current or past thermal temperatures of at least a portion of a graphics processing unit (GPU). The logic selects the one or more compute units to process the plurality of threads based on the determined characteristic and the temperature information. The logic provides instructions to the selected subset of the plurality of CUs to execute the wavefront.

Rao, Karthik↗

Improved Evaluation of Large Network Matrices for Linear Power Flow Within Optimization Problems: Preprint

This work discusses methods for evaluating the Power Transfer Distribution Factor (PTDF) and Line Outage Distribution Factor (LODF) matrices by employing sparse linear algebra for large-scale computing applications. These matrices are critical in many power systems applications, such as the Unit Commitment Problem (UC), pre- and post-contingency power flow analysis, and transmission expansion. These matrices are typically dense, which means they require a significant amount of time and memory to be computed for large networks. However, by analyzing the structure of the matrices and their computation method, it is possible to use reduced memory methods based on sparse matrix operations. This paper shows that sparse linear algebra algorithms are faster and require less memory and time than traditional dense approaches. Additionally, we explore the effect of matrix sparsification by eliminating trailing digits on power flow calculations.

ENERGY PLANNING, POLICY, AND ECONOMY↗

SBbadger: biochemical reaction networks with definable degree distributions

Abstract Motivation An essential step in developing computational tools for the inference, optimization and simulation of biochemical reaction networks is gauging tool performance against earlier efforts using an appropriate set of benchmarks. General strategies for the assembly of benchmark models include collection from the literature, creation via subnetwork extraction and de novo generation. However, with respect to biochemical reaction networks, these approaches and their associated tools are either poorly suited to generate models that reflect the wide range of properties found in natural biochemical networks or to do so in numbers that enable rigorous statistical analysis. Results In this work, we present SBbadger, a python-based software tool for the generation of synthetic biochemical reaction or metabolic networks with user-defined degree distributions, multiple available kinetic formalisms and a host of other definable properties. SBbadger thus enables the creation of benchmark model sets that reflect properties of biological systems and generate the kinetics and model structures typically targeted by computational analysis and inference software. Here, we detail the computational and algorithmic workflow of SBbadger, demonstrate its performance under various settings, provide sample outputs and compare it to currently available biochemical reaction network generation software. Availability and implementation SBbadger is implemented in Python and is freely available at https://github.com/sys-bio/SBbadger and via PyPI at https://pypi.org/project/SBbadger/. Documentation can be found at https://SBbadger.readthedocs.io. Supplementary information Supplementary data are available at Bioinformatics online.

59 BASIC BIOLOGICAL SCIENCES↗

2022 Small Turbine Certification Awardee: Ryse Energy LLC - Americas

To meet the growing demands of the distributed wind market and comply with current U.S. standards, Ryse Energy LLC-Americas (Ryse Energy, formerly Primus Wind Power) plans to update all six products in its AIR Range family of micro wind turbines. A new, more cost-effective circuit board will be paired with other hardware upgrades, advanced control algorithms, and a Bluetooth function that allows users to more easily program and control the turbine. This Competitiveness Improvement Project (CIP) award will fund certification testing of the new circuit board to make sure it meets American National Standards Institute/American Clean Power Association (ANSI/ACP) and UL Federal Communications Commission (FCC) safety and quality standards. Primus Wind Power developed the prototype for the new circuit board with an earlier round of CIP funding, and Primus has received CIP awards supporting other certification and optimization projects.

CIP↗

Method and system for providing flexible reserve power for power grid

An optimization-based method and system is disclosed to enable heterogeneous loads and distributed energy resources (DERs) to participate in grid ancillary services, such as spinning and non-spinning reserves, and ramping reserves. The method includes receiving inputs for decision parameters for optimizing an objective for obtaining flexible reserve power, solving the objective for obtaining flexible reserve power, determining a reserve power schedule for a prediction horizon for providing flexible reserve power based on the objective, generating a service bid based on the reserve power schedule for the power grid; and when the service bid is accepted, providing flexible reserve power to the power grid based on the service bid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Arbitrage and Capacity Firming in Coordination with Day-Ahead Bidding of a Hybrid PV Plant

A hybrid PV plant (HPP) combines a photovoltaic (PV) plant with a battery energy storage system (BESS), which is considered a promising step towards the future of renewable power plants by the U.S. Department of Energy. When the renewable penetration reaches a significant level, a hybrid PV plant can bid in as a controllable thermal plant in the future electricity market. In this study, a bidding and BESS scheduling model is proposed for the HPP. The robust optimization (RO) technique has been utilized to identify the worst-case scenario of uncertainties during the bidding process. To address the overly conservative issue of the single-stage RO, we have decoupled the BESS schedule for arbitrage and PV capacity firming by a two-stage RO formulation. By comparing the output of single-stage RO and two-stage RO, the two-stage RO bids and schedules in a more aggressive manner, which increases the income of HPP. Also, the penalty of under-generation is considered in our model so that the day-ahead bidding decision and arbitrage schedules can be adjusted based on the potential UNDER-GENERATION penalty. Because the proposed model is non-convex and contains multi-stages, the Column-and-Constraint Generation (C&CG) algorithm is applied to the model as the solution. The proposed model has shown better economic performance compared to a state-of-art single-stage bidding method in case studies.

BESS scheduling↗