Search NASA⌕ Search

SEARCH · Search NASA

Results for “Infrared techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

On the Use of Deep Convective Clouds to Calibrate AVHRR Data

Remote sensing of cloud and radiation properties from National Oceanic and Atmospheric Administration (NOAA) Advanced Very High Resolution Radiometer (AVHRR) satellites requires constant monitoring of the visible sensors. NOAA satellites do not have onboard visible calibration and need to be calibrated vicariously in order to determine the calibration and the degradation rate. Deep convective clouds are extremely bright and cold, are at the tropopause, have nearly a Lambertian reflectance, and provide predictable albedos. The use of deep convective clouds as calibration targets is developed into a calibration technique and applied to NOAA-16 and NOAA-17. The technique computes the relative gain drift over the life-span of the satellite. This technique is validated by comparing the gain drifts derived from inter-calibration of coincident AVHRR and Moderate-Resolution Imaging Spectroradiometer (MODIS) radiances. A ray-matched technique, which uses collocated, coincident, and co-angled pixel satellite radiance pairs is used to intercalibrate MODIS and AVHRR. The deep convective cloud calibration technique was found to be independent of solar zenith angle, by using well calibrated Visible Infrared Scanner (VIRS) radiances onboard the Tropical Rainfall Measuring Mission (TRMM) satellite, which precesses through all solar zenith angles in 23 days.

Doelling, David R.↗

Surface Analysis of 4-Aminothiophenol Adsorption at Polycrystalline Platinum Electrodes

Formation of self-assembled monolayer (SAM) of 4-aminothiophenol (4-ATP) on polycrystalline platinum electrodes has been studied by surface analysis and electrochemistry techniques. The 4-ATP monolayer was characterized by cyclic voltammetry (CV), Raman spectroscopy, reflection absorption infrared (RAIR) spectroscopy, and X-ray photoelectron spectroscopy (XPS). Cyclic voltammetry (CV) experiments give an idea about the packing quality of the monolayer. RAIR and Raman spectra for 4-ATP modified platinum electrodes showed the characteristic adsorption bands for neat 4-ATP indicating the adsorption of 4-ATP molecules on platinum surface. The adsorption on platinum was also evidenced by the presence of sulfur and nitrogen peaks by XPS survey spectra of the modified platinum electrodes. High resolution XPS studies and RAIR spectrum for platinum electrodes modified with 4-ATP indicate that molecules are sulfur-bonded to the platinum surface. The formation of S-Pt bond suggests that ATP adsorption gives up an amino terminated SAM. Thickness of the monolayer was evaluated via angle-resolved XPS (AR-XPS) analyses. Derivatization of 4-ATP SAM was performed using 16-Br hexadecanoic acid.

Rosario-Castro, Belinda I.↗

Biosensors for EVA: Muscle Oxygen and pH During Walking, Running and Simulated Reduced Gravity

During lunar excursions in the EVA suit, real-time measurement of metabolic rate is required to manage consumables and guide activities to ensure safe return to the base. Metabolic rate, or oxygen consumption (VO2), is normally measured from pulmonary parameters but cannot be determined with standard techniques in the oxygen-rich environment of a spacesuit. Our group developed novel near infrared spectroscopic (NIRS) methods to calculate muscle oxygen saturation (SmO2), hematocrit, and pH, and we recently demonstrated that we can use our NIRS sensor to measure VO2 on the leg during cycling. Our NSBRI-funded project is looking to extend this methodology to examine activities which more appropriately represent EVA activities, such as walking and running and to better understand factors that determine the metabolic cost of exercise in both normal and lunar gravity. Our 4 year project specifically addresses risk: ExMC 4.18: Lack of adequate biomedical monitoring capability for Constellation EVA Suits and EPSP risk: Risk of compromised EVA performance and crew health due to inadequate EVA suit systems.

Lee, S. M. C.↗

Classification of Clouds and Deep Convection from GEOS-5 Using Satellite Observations

With the increased resolution of global atmospheric models and the push toward global cloud resolving models, the resemblance of model output to satellite observations has become strikingly similar. As we progress with our adaptation of the Goddard Earth Observing System Model, Version 5 (GEOS-5) as a high resolution cloud system resolving model, evaluation of cloud properties and deep convection require in-depth analysis beyond a visual comparison. Outgoing long-wave radiation (OLR) provides a sufficient comparison with infrared (IR) satellite imagery to isolate areas of deep convection. We have adopted a binning technique to generate a series of histograms for OLR which classify the presence and fraction of clear sky versus deep convection in the tropics that can be compared with a similar analyses of IR imagery from composite Geostationary Operational Environmental Satellite (GOES) observations. We will present initial results that have been used to evaluate the amount of deep convective parameterization required within the model as we move toward cloud system resolving resolutions of 10- to 1-km globally.

Putman, William↗

Five Decades Observing Earth's Atmospheric Trace Gases Using Ultraviolet and Visible Backscatter Solar Radiation from Space

Over the last five decades, Earth’s atmosphere has been extensively monitored from space using different spectral ranges. Early efforts were directed at improving weather forecasts with the first meteorological satellites launched in the 1960s. Soon thereafter, the intersection between weather, climate and atmospheric chemistry led to the observation of atmospheric composition from space. During the 1970s the Nimbus satellite program started regular monitoring of ozone integrated columns and water vapor profiles using the Backscatter Ultraviolet Spectrometer, the Infrared Interferometer Spectrometer and the Satellite Infrared Spectrometer instruments. Five decades after these pioneer efforts, continuous progress in instrument design, and retrieval techniques allow researchers to monitor tropospheric concentrations of a wide range of species with implications for air quality, climate and weather. The time line of historic, present and future space-borne instruments measuring ultraviolet and visible backscattered solar radiation designed to quantify atmospheric trace gases is presented. We describe the instruments technological evolution and the basic concepts of retrieval theory. We include a review of algorithms developed for ozone, nitrogen dioxide, sulfur dioxide, formaldehyde, bromine monoxide, water vapor and glyoxal, a selection of studies using these algorithms, the challenges they face and how these challenges can be addressed. The paper ends by providing insights on the opportunities that new instruments will bring to the atmospheric chemistry, weather and air quality communities and how to address the pressing need for long-term, inter-calibrated data records necessary to monitor the response of the atmosphere to rapidly changing ecosystems.

Infrared Interferometer Spectrometer↗

Monitoring system for the quality assessment in additive manufacturing

Additive Manufacturing (AM) refers to a process by which a set of digital data -representing a certain complex 3dim design - is used to grow the respective 3dim real structure equal to the corresponding design. For the powder-based EOS manufacturing process a variety of plastic and metal materials can be used. Thereby, AM is in many aspects a very powerful tool as it can help to overcome particular limitations in conventional manufacturing. AM enables more freedom of design, complex, hollow and/or lightweight structures as well as product individualisation and functional integration. As such it is a promising approach with respect to the future design and manufacturing of complex 3dim structures. On the other hand, it certainly calls for new methods and standards in view of quality assessment. In particular, when utilizing AM for the design of complex parts used in aviation and aerospace technologies, appropriate monitoring systems are mandatory. In this respect, recently, sustainable progress has been accomplished by joining the common efforts and concerns of a manufacturer Additive Manufacturing systems and respective materials (EOS), along with those of an operator of such systems (MTU Aero Engines) and experienced application engineers (Carl Metrology), using decent know how in the field of optical and infrared methods regarding non-destructive-examination (NDE). The newly developed technology is best described by a high-resolution layer by layer inspection technique, which allows for a 3D tomography-analysis of the complex part at any time during the manufacturing process. Thereby, inspection costs are kept rather low by using smart image-processing methods as well as CMOS sensors instead of infrared detectors. Moreover, results from conventional physical metallurgy may easily be correlated with the predictive results of the monitoring system which not only allows for improvements of the AM monitoring system, but finally leads to an optimisation of the quality and insurance of material security of the complex structure being manufactured. Both, our poster and our oral presentation will explain the data flow between the above mentioned parties involved. A suitable monitoring system for Additive Manufacturing will be introduced, along with a presentation of the respective high resolution data acquisition, as well as the image processing and the data analysis allowing for a precise control of the 3dim growth-process.

36 MATERIALS SCIENCE↗

Far-infrared filters utilizing small particle scattering and antireflection coatings

High-transmission, low-pass scatter filters for blocking at wavelengths from 3.5 to 50 microns and single-layer antireflection coatings for optical materials used in the 25- to 300-micron region of the spectrum are described. The application of both techniques to liquid-He-cooled filters permits the construction of efficient low-pass and medium-width bandpass filters for use throughout the far infrared.

Armstrong, K. R.↗

Infrared Computer-Generated Holograms: Design and Application for the WFIRST Grism Using Wavelength-Tuning Interferometry

Interferometers using computer-generated holograms (CGHs) have become the industry standard to accurately measure aspheric optics. The CGH is a diffractive optical element that can create a phase or amplitude distribution and can be manufactured with low uncertainty using modern lithographic techniques. However, these CGHs have conventionally been used with visible light and piezo-shifting interferometers. Testing the performance of transmissive optics in the infrared requires infrared CGHs and an infrared interferometer. Such an instrument is used in this investigation, which introduces its phase shift via wavelength-tuning. A procedure on how to design and manufacture infrared CGHs and how these were successfully used to model and measure the Wide-Field Infrared Survey Telescope grism elements is provided. Additionally, the paper provides a parametric model, simulation results, and calculations of the errors and measurements that come about when interferometers introduce a phase variation via wavelength-tuning interferometry to measure precision aspheres.

Communication↗

WISE PHOTOMETRY FOR 400 MILLION SDSS SOURCES

We present photometry of images from the Wide-Field Infrared Survey Explorer (WISE) of over 400 million sources detected by the Sloan Digital Sky Survey (SDSS). We use a “forced photometry” technique, using measured SDSS source positions, star–galaxy classification, and galaxy profiles to define the sources whose fluxes are to be measured in the WISE images. We perform photometry with The Tractor image modeling code, working on our “unWISE” coaddds and taking account of the WISE point-spread function and a noise model. The result is a measurement of the flux of each SDSS source in each WISE band. Many sources have little flux in the WISE bands, so often the measurements we report are consistent with zero given our uncertainties. However, for many sources we get 3σ or 4σ measurements; these sources would not be reported by the “official” WISE pipeline and will not appear in the WISE catalog, yet they can be highly informative for some scientific questions. In addition, these small-signal measurements can be used in stacking analyses at the catalog level. The forced photometry approach has the advantage that we measure a consistent set of sources between SDSS and WISE, taking advantage of the resolution and depth of the SDSS images to interpret the WISE images; objects that are resolved in SDSS but blended together in WISE still have accurate measurements in our photometry. Our results, and the code used to produce them, are publicly available at http://unwise.me.

79 ASTRONOMY AND ASTROPHYSICS↗

Reactivity of C2Cl6 and C2Cl4 multilayers with Fe0 atoms over FeO(111)

The interaction of Fe0 atoms with C2Cl6 multilayers over FeO(111) has been investigated using the “atom dropping” preparation technique and a combination of temperature programmed desorption, Auger electron spectroscopy, and x-ray photoelectron spectroscopy. The reactivity and reaction products are strongly dependent on the Fe0 coverage. Submonolayer Fe0 doses lead to high reactivity and primarily FeCl3 and C4Cl6, whereas multilayer Fe0 doses lead to the production of FeCl2 and C2Cl4 with much lower Fe0 reactivity. The data are consistent with a model where Fe atoms form intermediate species at low coverage, which consist of a Fe atom inserted into a C-Cl bond. When two Fe atoms react with C2Cl6, a different intermediate species is formed which produces the alternative reaction pathway and the formation of C2Cl4. Similar atom dropping experiments demonstrate that C2Cl4 is also reactive towards Fe0 atoms at low Fe0 dose, leading to the production of one FeCl2 molecule per C2Cl4 molecule reacted. At higher coverages, Fe atoms form clusters which are much less reactive toward C2Cl4.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Moon - Near-infrared spectral reflectance, a first good look

Spectral reflectance contains direct information on the mineralogy of the surface soils and rocks. A problem concerning the employment of remote spectral-reflectance sensing techniques for mineralogical studies is related to the lack of photometrically precise spectra of planetary surfaces in the region from 1.0 to 2.5 micrometers, where additional important mineral absorptions occur. Recently, a new instrument was developed, and an observational program is underway to provide the required near-infrared spectra. The first, comprehensive near-infrared spectroscopic results for the moon are presented. It is shown that it is equally possible to derive quantitative mineralogical information about the lunar surface by using remotely sensed reflectance spectra as it is by using laboratory reflectance measurements of lunar samples.

Mccord, T. B.↗

Modeling of infrared flux spectra from disk-shaped interstellar dust clouds

Although there is growing observational and theoretical evidence for many disk-shaped objects of astrophysical interest, spherical geometry is assumed in most radiative transfer models. Recently we generalized the quasi-diffusion method developed by Leung (1975, 1976) for spherical geometry to solve the problem of scattering, absorption, and reemission by dust grains in a medium of disk geometry. The method is applicable to a variety of astronomical sources whose dynamics are angular-momentum dominated and hence not accurately treated by spherical geometry, e.g., protoplanetary nebulae, circumstellar disks, bipolar-flow molecular clouds, accretion disks and disk galaxies. Using this technique and realistic grain opacities we construct theoretical models to determine self-consistently the dust temperature distribution and infrared emission from disk-shaped, quiescent dark globules heated externally by the intersteller radiation field. The effects of the following parameters on the temperature structure and the emergent spectrum are studied: grain type (graphite and silicate), optical depth, density inhomogeneity, and degree of disk flattening. The disk models are characterized by an aspect ratio and an optical depth at 0.55 microns. For inhomogeneous models, a gaussian density distribution is assumed such that the ratio of central to surface density is 100. To study the effects of source geometry, we also compare results for models with spherical and disk geometry. In this case both models have the same radius and central optical depth, the disk models having a 1:1 aspect ratio. While the dust temperature distributions in the two cases are very similar, the emergent flux for the disk model depends sensitively on the viewing angle. For clouds which are unresolved, one would expect, since the thermal emission is isotropic in the neighborhood of an emitting grain, and since the emission (in the far infrared) is optically thin, that the emergent flux spectrum should be characteristic only of the dust temperature, and independent of viewing angle. However, because of the lack of complete symmetry and the resulting radiation anisotropy, this is found not to be the case for the disk models. Angle is that it implies a large uncertainty in estimating the radiation dust mass.

Spagna, G. F., Jr.↗

The application of Fourier transform spectroscopy to the remote identification of solids in the solar system

The techniques of Fourier transform spectroscopy combined with large aperture telescopes and advances in detector technology now permit infrared (at a wavelength greater than 1 micron) observations of the surfaces of small solar system objects such as asteroids and satellites. The results demonstrate that this activity can produce important new compositional information related to the origin and evolution of the solar system. The detection of water ice in Saturn's rings and on some of the satellites of Jupiter and Saturn confirm expectations that ices are important mineralogical components in the chemistry of the outer solar system. More recent studies of the mineralogical composition of the surfaces of asteroids provide a new observational link to the origin of meteorites and the early thermal history of the solar system. These results have been dependent upon supporting laboratory studies of the spectral behavior of ices and minerals to define the potential, and limitations, of the method. Since many of the astronomical observations have been exploratory in nature, prospects are good that continued refinement of the techniques will lead to additional insights.

Larson, H. P.↗

Assessment of MODIS On-Orbit Calibration Using a Deep Convective Cloud Technique

The MODerate Resolution Imaging Spectroradiometer (MODIS) sensors onboard Terra and Aqua satellites are calibrated on-orbit with a solar diffuser (SD) for the reflective solar bands (RSB). The MODIS sensors are operating beyond their designed lifetime and hence present a major challenge to maintain the calibration accuracy. The degradation of the onboard SD is tracked by a solar diffuser stability monitor (SDSM) over a wavelength range from 0.41 to 0.94 micrometers. Therefore, any degradation of the SD beyond 0.94 micrometers cannot be captured by the SDSM. The uncharacterized degradation at wavelengths beyond this limit could adversely affect the Level 1B (L1B) product. To reduce the calibration uncertainties caused by the SD degradation, invariant Earth-scene targets are used to monitor and calibrate the MODIS L1B product. The use of deep convective clouds (DCCs) is one such method and particularly significant for the short-wave infrared (SWIR) bands in assessing their long-term calibration stability. In this study, we use the DCC technique to assess the performance of the Terra and Aqua MODIS Collection-6 L1B for RSB 1 3- 7, and 26, with spectral coverage from 0.47 to 2.13 micrometers. Results show relatively stable trends in Terra and Aqua MODIS reflectance for most bands. Careful attention needs to be paid to Aqua band 1, Terra bands 3 and 26 as their trends are larger than 1% during the study time period. We check the feasibility of using the DCC technique to assess the stability in MODIS bands 17-19. The assessment test on response versus scan angle (RVS) calibration shows substantial trend difference for Aqua band 1between different angles of incidence (AOIs). The DCC technique can be used to improve the RVS calibration in the future.

Mu, Qiaozhen↗

Variability of biomass chemical composition and rapid analysis using FT-NIR techniques

A quick method for analyzing the chemical composition of renewable energy biomass feedstock was developed by using Fourier transform near-infrared (FT-NIR) spectroscopy coupled with multivariate analysis. The study presents the broad-based model hypothesis that a single FT-NIR predictive model can be developed to analyze multiple types of biomass feedstock. The two most important biomass feedstocks corn stover and switchgrass were evaluated for the variability in their concentrations of the following components: glucan, xylan, galactan, arabinan, mannan, lignin, and ash. A hypothesis test was developed based upon these two species. Both cross-validation and independent validation results showed that the broad-based model developed is promising for future chemical prediction of both biomass species; in addition, the results also showed the method's prediction potential for wheat straw.

09 BIOMASS FUELS↗

Development of a Test Technique to Determine the Thermal Conductivity of Large Refractory Ceramic Test Specimens

A method has been developed to utilize the High Intensity Infrared lamp located at Oak Ridge National Laboratory for the measurement of thermal conductivity of bulk refractory materials at elevated temperatures. The applicability of standardized test methods to determine the thermal conductivity of refractory materials at elevated temperatures is limited to small sample sizes (laser flash) or older test methods (hot wire, guarded hot plate), which have their own inherent problems. A new method, based on the principle of the laser flash method, but capable of evaluating test specimens on the order of 200 x 250 x 50 mm has been developed. Tests have been performed to validate the method and preliminary results are presented in this paper.

36 MATERIALS SCIENCE↗

FY17 Status Report for the Development of Infrared Thermography for In-Pile Fuel Behavior Applications

Under a Department of Energy Office of Nuclear Energy (DOE-NE) initiative to develop in-pile instrumentation, an activity has been initiated to develop an infrared thermography (IRT) approach for in-reactor monitoring of fuel behaviors. The project will focus on leveraging mature, mainstream IRT techniques for use on nuclear fuel systems inside a nuclear reactor through unique adaptations for remote applications – an extremely challenging engineering and measurement objective – never before accomplished in-pile. To this end, some of the most important issues to be addressed include identifying an optimal IRT configuration (of many possible) and components for detecting specific structural evolutions such as fuel cracking and fuel void formation and migration; developing a long distance imaging system to transmit high resolution infrared images from a small specimen surface in the harsh environment of a reactor core to a IR camera or other detector array; and ultimately, integrating a complete experimental system to create a full in-reactor experiment. This document provides an overview of potential in-pile applications of IRT, a brief overview of IRT techniques, a detailed research plan and schedule for the project, and a summary of activities that have been initiated in the closing months of fiscal year 2017.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ferrocene adsorbed into the porous octakis(hydridodimethylsiloxy)silsesquioxane after thermolysis in tetrahydrofuran media: An applied surface for ascorbic acid determination

Highlights: Black-Right-Pointing-Pointer Octakis(hydridodimethylsiloxi)silsesquioxane was synthesized and Ferrocene was adsorbed. Black-Right-Pointing-Pointer Polymeric net through electrostatic interactions was observed. Black-Right-Pointing-Pointer The novel materials presents electroacatalytic activity for Ascorbic acid. -- Abstract: Octakis(hydridodimethylsiloxi)silsesquioxane (Q{sub 8}M{sub 8}{sup H}) was synthesized and Ferrocene was adsorbed in a polymeric net through electrostatic interactions, with anion forming after the cleavage of any siloxy groups (ESFc). The nanostructured materials (Q{sub 8}M{sub 8}{sup H} and EsFc) were characterized by Fourier transform infrared spectra (FT-IR), nuclear magnetic resonance (NMR), X-ray diffraction (XRD), Thermogravimetric analyses and Voltammetric technique The cyclic voltammograms of the graphite paste electrode modified with ESFc showed one redox couple with E{sup 0} Prime = 0.320 V (1.0 mol L{sup -1} NaCl, v = 50 mV s{sup -1}), with a diffusion-controlled process and the redox process shows electrocatalytic activity for the oxidation of ascorbic acid.

36 MATERIALS SCIENCE↗