Search NASA⌕ Search

SEARCH · Search NASA

Results for “Instrument Development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Postirradiation Examination of WIRE-21 Experiment Irradiated in the High Flux Isotope Reactor

Westinghouse Electric Company is developing wireless sensors to monitor the centerline temperature and internal pressure of commercial light-water reactor fuel rods during irradiation. Oak Ridge National Laboratory and Westinghouse Electric Company developed the Wireless Instrumented RB Experiment 2021 (WIRE-21) to test wireless temperature and pressure sensor technologies in a removable beryllium position in the High Flux Isotope Reactor. The experiment was irradiated for a total of 75 days, at temperatures ranging from approximately 150°C to 400°C, resulting in a peak fast (energy > 0.1 MeV) neutron fluence of about 3 × 10 21 n/cm 2 . The temperature was intentionally cycled multiple times to compare the response of the wireless temperature sensor to collocated thermocouples. Similarly, the pressure sensor was actuated in multiple steps to compare the response of the wireless measurement to excore pressure transducers (Petrie et al., 2023). After irradiation, the experiment was disassembled in the Irradiated Fuels Examination Laboratory (IFEL) hot cell at Oak Ridge National Laboratory with the intent to recover sensor and dosimetry components, document the as-irradiated condition of the hardware, and investigate possible causes of the sensor behavior observed during irradiation. The postirradiation examination successfully recovered and preserved key WIRE-21 components. After the housing was removed using a milling machine, the internal experiment sections were examined. All eight fiber-optic sensors were recovered, cut, and stored. The silicon carbide thermometry, temperature sensor, pressure sensor, lower spacer, and selected pressure and temperature cable sections were also removed and stored. The metal bellows of the pressure sensor was found to be plastically deformed, indicating that it had been properly pressurized during irradiation and generally behaved as expected. X-ray diffraction analysis of a section of one of the irradiated inductor cores within the pressure sensor was performed and confirmed the presence of phase-pure alpha ferrite (i.e., no unexpected phase transformations). Inductance testing was performed on the irradiated pressure sensor cores using an unirradiated test coil, and DC resistance measurements of the transceiver coils were also performed. The measurements with irradiated inductor cores assembled inside unirradiated coils showed slightly reduced inductance compared to measurements made with unirradiated cores, but the difference was not sufficient to explain the more significant reductions in inductance that were observed in-pile. Therefore, it is suspected that degradation of the inductor coils (specifically the wire wrapping) is responsible for the reduced inductance observed in-pile.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fiber Optic Temperature Sensor System Using Air-Filled Fabry–Pérot Cavity with Variable Pressure

We report a high-resolution fiber optic temperature sensor system based on an air-filled Fabry–Pérot (FP) cavity, whose spectral fringes shift due to a precise pressure variation in the cavity. The absolute temperature can be deduced from the spectral shift and the pressure variation. For fabrication, a fused-silica tube is spliced with a single-mode fiber at one end and a side-hole fiber at the other to form the FP cavity. The pressure in the cavity can be changed by passing air through the side-hole fiber, causing the spectral shift. We analyzed the effect of sensor wavelength resolution and pressure fluctuation on the temperature measurement resolution. A computer-controlled pressure system and sensor interrogation system were developed with miniaturized instruments for the system operation. Experimental results show that the sensor had a high wavelength resolution (<0.2 pm) with minimal pressure fluctuation (~0.015 kPa), resulting in high-resolution (±0.32 ℃) temperature measurement. It shows good stability from the thermal cycle testing with the maximum testing temperature reaching 800 ℃.

47 OTHER INSTRUMENTATION↗

Method for measuring static Young's modulus of tungsten to 1900 K

An instrument system was developed and tested to measure static Young's modulus of elasticity of refractory metals in tension at temperatures to 1900 K. The extensometer uses capacitance displacement sensors for measuring total elongation of a specimen and incorporates a unique high-resolution remote zero-adjusting mechanism. Details of a method for calibrating capacitance displacement sensors at temperatures to 800 K are included. The system was built to adapt to a vacuum furnace on a tensile machine and was tested on unalloyed tungsten rod specimens. The test results show that the system can measure the modulus of tungsten to 1900 K to within a precision of + or - 5 percent. The uncertainty of the measurement is estimated to be of the same order as the precision.

Harrigill, W. T., Jr.↗

Fluorescence activated cell sorting.

An instrument has been developed for sorting biological cells. The cells are rendered differentially fluorescent and incorporated into a small liquid stream illuminated by a laser beam. The cells pass sequentially through the beam, and fluorescent light from the cells gives rise to electrical signals. The stream is broken into a series of uniform size drops downstream of the laser. The cell signals are used to give appropriate electrostatic charges to drops containing the cells. The drops then pass between two charged plates and are deflected to appropriate containers. The system has proved capable of providing fractions containing large numbers of viable cells highly enriched in a particular functional type.

Bonner, W. A.↗

Aerospace reliability applied to biomedicine.

An analysis is presented that indicates that the reliability and quality assurance methodology selected by NASA to minimize failures in aerospace equipment can be applied directly to biomedical devices to improve hospital equipment reliability. The Space Electric Rocket Test project is used as an example of NASA application of reliability and quality assurance (R&QA) methods. By analogy a comparison is made to show how these same methods can be used in the development of transducers, instrumentation, and complex systems for use in medicine.

Lalli, V. R.↗

Physiological responses to environmental factors related to space flight

The research is reported for establishing physiological base line data, and for developing procedures and instrumentation necessary for the automatic measurement of hemodynamic and metabolic parameters. The work in the following areas is discussed: biochemistry, bioinstrumentation, nutrition, physiology, experimental surgery, and animal colony.

Pace, N.↗

Preliminary design study for an atomospheric science facility

The activities and results of the Atmospheric Science Facility preliminary design study are reported. The objectives of the study were to define the scientific goals, to determine the range of experiment types, and to develop the preliminary instrument design requirements for a reusable, general purpose, optical research facility for investigating the earth's atmosphere from a space shuttle orbital vehicle.

Hutchison, R.↗

Theory of zone radiometry

A spectroscopic instrumentation system was developed which was used to measure temperature and concentration distributions in axisymmetric and two dimensional combusting flows. This measurement technique is known as zone radiometry.

Farmer, R. C.↗

A programmable computer interface for CAMAC

An interface has been developed for CAMAC instrumentation systems that implements data transfers controlled either by the computer CPU or by an autonomous (data-channel) processor in the interface unit. The data channel processor executes programs stored in the computer memory. These programs consist of standard CAMAC module commands plus special control characters and commands for the processor itself. The interface was built for the PDP-15 computer, which has an 18-bit word structure, but both 18- and 24-bit data transfers can be made. A software system has been written that exploits the many features of the processor.

Bercaw, R. W.↗

The oculometer - A new approach to flight management research.

For the first time researchers have an operational, nonintrusive instrument for determining a pilot's eye-point-of-regard without encumbering the pilot or introducing other artifacts into the simulation of flight experience. The instrument (the oculometer developed for NASA by Honeywell, Inc.) produces data in a form appropriate for online monitoring and rapid analysis using state-of-the-art display and computer technology. The type and accuracy of data obtained and the potential use of the oculometer as a research and training tool will be discussed.

Spady, A. A., Jr.↗

Air pollution measurements from satellites

A study is presented on the remote sensing of gaseous and particulate air pollutants which is an extension of a previous report. Pollutants can be observed by either active or passive remote sensing systems. Calculations discussed herein indicate that tropospheric CO, CO2, SO2, NO2, NH3, HCHO, and CH4 can be measured by means of nadir looking passive systems. Additional species such as NO, HNO3, O3, and H2O may be measured in the stratosphere through a horizon experiment. A brief theoretical overview of resonance Raman scattering and resonance fluorescence is given. It is found that radiance measurements are most promising for general global applications, and that stratospheric aerosols may be measured using a sun occultation technique. The instrumentation requirements for both active and passive systems are examined and various instruments now under development are described.

Ludwig, C. B.↗

An S-band radiometer design with high absolute precision

A radiometer for the remote measurement of sea surface temperature is described. The development of an instrument capable not only of high relative accuracy (i.e., resolution) but also of high absolute precision is considered. The concepts underlying the design of an instrument capable of an absolute accuracy of a few tenths degrees Kelvin in the measurement of brightness temperature at S band are described. The role of the antenna is discussed, and the importance of high ohmic and beam efficiencies is stressed. The hardware itself is fully described, along with an outline concerning the design of a unique cryogenically cooled termination used to calibrate the whole radiometer, including antenna. Finally, some test results are presented that show that the design goals for the instrument have been closely approached.

Hardy, W. N.↗

An assessment of warm fog: Nucleation, control, and recommended research

A state-of-the-art survey is given of warm fog research which has been performed up to, and including, 1974. Topics covered are nucleation, growth, coalescence, fog structures and visibility, effects of surface films, drop size spectrum, optical properties, instrumentation, liquid water content, condensation nuclei. Included is a summary of all reported fog modification experiments. Additional data is provided on air flow, turbulence, a summary of recommendations on instruments to be developed for determining turbulence, air flow, etc., as well as recommendations of various fog research tasks which should be performed for a better understanding of fog microphysics.

Corrin, M. L.↗

CAMAC and NIM systems in the space program

The CAMAC and NIM instrumentation systems were developed originally to serve the needs of nuclear research institutions in Europe and North America. CAMAC and NIM are currently considered in several studies at the systems level conducted by NASA and ESRO groups. NIM and CAMAC studies for applications related to the space shuttle are discussed along with the advantages provided by aspects of modularization and standardization, a use of NIM and CAMAC equipment in connection with a group of astrophysics experiments, and questions of cost effectiveness.

Trainor, J. H.↗

Optical devices

Report describes thirty concepts and techniques developed for optical instrumentation and light transmission and generation, including spectrometer components, telescopes and microscopes, and holographic cameras.

Source record↗

Laboratory-scale uranium RF plasma confinement experiments

An experimental investigation was conducted using 80 kW and 1.2 MW RF induction heater facilities to aid in developing the technology necessary for designing a self-critical fissioning uranium plasma core reactor. Pure uranium hexafluoride (UF6) was injected into argon-confined, steady-state, RF-heated plasmas in different uranium plasma confinement tests to investigate the characteristics of plamas core nuclear reactors. The objectives were: (1) to confine as high a density of uranium vapor as possible within the plasma while simultaneously minimizing the uranium compound wall deposition; (2) to develop and test materials and handling techniques suitable for use with high-temperature, high-pressure gaseous UF6; and (3) to develop complementary diagnostic instrumentation and measurement techniques to characterize the uranium plasma and residue deposited on the test chamber components. In all tests, the plasma was a fluid-mechanically-confined vortex-type contained within a fused-silica cylindrical test chamber. The test chamber peripheral wall was 5.7 cm ID by 10 cm long.

Roman, W. C.↗