Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linearization error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Influence of anomalous perpendicular transport on linear tearing mode dynamics in tokamak plasmas

The analysis of a previous paper [A. Cole and R. Fitzpatrick, Phys. Plasmas 13, 032503 (2006)] that maps out all of the two-fluid response regimes of a linear tearing layer interacting with an externally generated resonant magnetic perturbation, in a large aspect-ratio tokamak plasma, is generalized to take into account realistic levels of perpendicular particle transport. A new response-regime map is obtained that differs substantially, in many respects, from the old one. The improved analysis is first employed to find all of the two-fluid growth-rate regimes of a non-interacting low-mode-number tearing mode in a large aspect-ratio tokamak plasma. The analysis is then used to determine the scaling of the error-field penetration threshold with machine parameters in large aspect-ratio tokamak plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Variational AutoEncoders Reveal Intensifying GPP Extremes in Continental United States based on CESM2 Simulations

Climate extremes significantly impact terrestrial carbon cycle dynamics, necessitating robust methods for detecting and analyzing anomalous behavior in plant productivity. This study presents a novel application of variational autoencoders (VAE) for identifying extreme events in gross primary productivity (GPP) from Community Earth System Model version 2 simulations across four AR6 regions in the Continental United States. We compare VAE-based anomaly detection with traditional singular spectral analysis (SSA) methods across three time periods: 1850-80, 1950-80, and 2050-80 under SSP5-8.5 scenario. The VAE architecture employs three dense layers and a latent space with input sequence length of 12 months, training on normalized GPP time series to reconstruct the GPP and identify anomalies based on reconstruction errors. Extreme events are defined using 5th percentile thresholds applied to both VAE and SSA anomalies. Results demonstrate strong regional agreement between VAE and SSA methods in spatial patterns of extreme event frequencies, despite VAE consistently producing higher threshold values (179-756 GgC for VAE vs. 100-784 GgC for SSA across regions and periods). Both methods reveal increasing magnitudes and frequencies of negative carbon cycle extremes toward 2050-80, particularly in Western and Central North America. The VAE approach shows comparable performance to established SSA techniques while offering computational advantages and enhanced capability for capturing non-linear temporal dependencies in carbon cycle variability. This research demonstrates the potential of deep learning approaches for extremes detection and provides a foundation for improved understanding of future carbon cycle risks under future conditions.

Sharma, Bharat [ORNL] (ORCID:0000000266982487)↗

TH-CD-202-06: A Method for Characterizing and Validating Dynamic Lung Density Change During Quiet Respiration

Purpose: To obtain a functional relationship that calibrates the lung tissue density change under free breathing conditions through correlating Jacobian values to the Hounsfield units. Methods: Free-breathing lung computed tomography images were acquired using a fast helical CT protocol, where 25 scans were acquired per patient. Using a state-of-the-art deformable registration algorithm, a set of the deformation vector fields (DVF) was generated to provide spatial mapping from the reference image geometry to the other free-breathing scans. These DVFs were used to generate Jacobian maps, which estimate voxelwise volume change. Subsequently, the set of 25 corresponding Jacobian and voxel intensity in Hounsfield units (HU) were collected and linear regression was performed based on the mass conservation relationship to correlate the volume change to density change. Based on the resulting fitting coefficients, the tissues were classified into parenchymal (Type I), vascular (Type II), and soft tissue (Type III) types. These coefficients modeled the voxelwise density variation during quiet breathing. The accuracy of the proposed method was assessed using mean absolute difference in HU between the CT scan intensities and the model predicted values. In addition, validation experiments employing a leave-five-out method were performed to evaluate the model accuracy. Results: The computed mean model errors were 23.30±9.54 HU, 29.31±10.67 HU, and 35.56±20.56 HU, respectively, for regions I, II, and III, respectively. The cross validation experiments averaged over 100 trials had mean errors of 30.02 ± 1.67 HU over the entire lung. These mean values were comparable with the estimated CT image background noise. Conclusion: The reported validation experiment statistics confirmed the lung density modeling during free breathing. The proposed technique was general and could be applied to a wide range of problem scenarios where accurate dynamic lung density information is needed. This work was supported in part by NIH R01 CA0096679.

60 APPLIED LIFE SCIENCES↗

SU-F-18C-10: Clinical Implementation of Radiochromic Film Based CTDI Measurements

Purpose: To evaluate accuracy and reproducibility of a radiochromic film-based protocol to measure computer tomography dose index (CTDI) as a part of annual QA on CT scanners and kV CBCT systems attached to linear accelerators. Methods: Energy dependence of Gafchromic XR-QA2(R) film model was tested over imaging beam qualities (50 – 140 kVp). Film pieces were irradiated in air to known values of air kerma in air (up to 10 cGy). Change in film reflectance was determined with an in-house written code using images produced by a flatbed document scanner. Calibration curves for each beam quality were created, and film responses for same air-kerma values were compared.Sets of film strips were placed into holes of a CTDI phantom and irradiated for several clinical scanning protocols on CT-simulators and CBCT systems. Film reflectance change was converted into dose to water and used to calculate CTDIvol values. Measured CTDIvol values were compared to tabulated CTDIvol values. Results: Average variations of ±5.2% in the mean film reflectance change were observed in the energy range of 80 to 140 keV, and 11.1% between 50 and 140 keV. The averaged measured CTDI values presented a mean variation for the same machine and protocol of 2.6%. However, measured CTDI values were in average 10% lower than tabulated CTDI values for CT-simulators, and 44% higher for CBCT systems. Conclusion: We found that in relatively broad range of beam qualities used in diagnostic radiology variation of film response is within ±5% resulting in ±15% systematic error in dose estimates if a single calibration curve is used. Relatively large discrepancy between measured and tabulated CTDI values for different protocols and imaging systems used within radiotherapy department strongly support the trend towards replacing CTDI value with equilibrium dose measurement in the center of cylindrical phantom as suggested by TG-111. This work was supported by the Natural Sciences and Engineering Research Council of Canada, Contract No. 386009; Partial support by CREATE, Medical Physics Research Training Network grant of the Natural Science and Engineering Research Council, Contract No. 432290.

07 ISOTOPE AND RADIATION SOURCES↗

Predicting battery capacity from impedance at varying temperature and state of charge using machine learning

Prediction of battery health from electrochemical impedance spectroscopy (EIS) data can enable rapid measurement of battery state in real-world applications without using additional sensors or time-consuming performance measurements. However, deconvoluting the effect of capacity, state of charge, and temperature on EIS response is complicated analytically. Here, various machine-learning models, such as linear, Gaussian process, random forest, and artificial neural network regression, are utilized to predict capacity from EIS using hundreds of capacity, direct current (DC) resistance, and EIS measurements recorded under varying conditions of health, temperature, and state of charge (SOC). Several feature extraction and selection methods from traditional electrochemical analysis and statistical modeling are explored using machine-learning pipelines. EIS data from just two frequencies can accurately predict capacity, and interrogation shows that the optimal set of frequencies is not usually intuitive. Best results are achieved with an ensemble model, which predicts battery capacity with a mean absolute error of 1.9% on data from unobserved cells.

25 ENERGY STORAGE↗

Modeling MTS pyrolysis and SiC deposition kinetics using principal component analysis and neural networks

Accurate chemical kinetics modeling is crucial for improving the efficiency of chemical processing and synthesis of ceramic matrix composites. Detailed kinetic models are computationally expensive due to the large number of transported chemical species, while the simplified physics-based models, such as single-step global mechanisms, are efficient but often overlook key chemical intermediates and pathways. Recent deep learning approaches promise accurate and cost-effective models. Yet, they require additional closures for the transported nonlinear latent variables, complicating integration with existing solvers. In this work, we develop a hybrid linear—nonlinear reduced model for silicon carbide deposition from methyltrichlorosilane precursor by combining principal component analysis (PCA) and autoencoder (AE) neural network (NN) approaches. PCA is used to identify a smaller set of linear transport variables, enabling direct reuse of conventional transport solvers. NNs then reconstruct the full chemical state from these reduced variables. We demonstrate the method on a chemical vapor deposition reactor—comprising a gas-phase pyrolysis plug flow reactor and a heterogeneous surface reactor—over a wide range of temperatures, pressures, and residence times. Our PCA–AE model achieves high accuracy with only five transported scalars, achieving an eightfold cost reduction compared to detailed mechanisms, in both a priori (using data from the test set only) and a posteriori (coupled with a differential equation solver). In conclusion, notable errors arise primarily near training domain boundaries and for long residence times, indicating the need for domain shift indicators and better long-horizon predictions in future reduced chemistry model development.

autoencoder neural networks↗

Anatomical pulmonary magnetic resonance imaging segmentation for regional structure-function measurements of asthma

Purpose: Pulmonary magnetic-resonance-imaging (MRI) and x-ray computed-tomography have provided strong evidence of spatially and temporally persistent lung structure-function abnormalities in asthmatics. This has generated a shift in their understanding of lung disease and supports the use of imaging biomarkers as intermediate endpoints of asthma severity and control. In particular, pulmonary {sup 1}H MRI can be used to provide quantitative lung structure-function measurements longitudinally and in response to treatment. However, to translate such biomarkers of asthma, robust methods are required to segment the lung from pulmonary {sup 1}H MRI. Therefore, their objective was to develop a pulmonary {sup 1}H MRI segmentation algorithm to provide regional measurements with the precision and speed required to support clinical studies. Methods: The authors developed a method to segment the left and right lung from {sup 1}H MRI acquired in 20 asthmatics including five well-controlled and 15 severe poorly controlled participants who provided written informed consent to a study protocol approved by Health Canada. Same-day spirometry and plethysmography measurements of lung function and volume were acquired as well as {sup 1}H MRI using a whole-body radiofrequency coil and fast spoiled gradient-recalled echo sequence at a fixed lung volume (functional residual capacity + 1 l). We incorporated the left-to-right lung volume proportion prior based on the Potts model and derived a volume-proportion preserved Potts model, which was approximated through convex relaxation and further represented by a dual volume-proportion preserved max-flow model. The max-flow model led to a linear problem with convex and linear equality constraints that implicitly encoded the proportion prior. To implement the algorithm, {sup 1}H MRI was resampled into ∼3 × 3 × 3 mm{sup 3} isotropic voxel space. Two observers placed seeds on each lung and on the background of 20 pulmonary {sup 1}H MR images in a randomized dataset, on five occasions, five consecutive days in a row. Segmentation accuracy was evaluated using the Dice-similarity-coefficient (DSC) of the segmented thoracic cavity with comparison to five-rounds of manual segmentation by an expert observer. The authors also evaluated the root-mean-squared-error (RMSE) of the Euclidean distance between lung surfaces, the absolute, and percent volume error. Reproducibility was measured using the coefficient of variation (CoV) and intraclass correlation coefficient (ICC) for two observers who repeated segmentation measurements five-times. Results: For five well-controlled asthmatics, forced expiratory volume in 1 s (FEV{sub 1})/forced vital capacity (FVC) was 83% ± 7% and FEV{sub 1} was 86 ± 9%{sub pred}. For 15 severe, poorly controlled asthmatics, FEV{sub 1}/FV C = 66% ± 17% and FEV{sub 1} = 72 ± 27%{sub pred}. The DSC for algorithm and manual segmentation was 91% ± 3%, 92% ± 2% and 91% ± 2% for the left, right, and whole lung, respectively. RMSE was 4.0 ± 1.0 mm for each of the left, right, and whole lung. The absolute (percent) volume errors were 0.1 l (∼6%) for each of right and left lung and ∼0.2 l (∼6%) for whole lung. Intra- and inter-CoV (ICC) were <0.5% (>0.91%) for DSC and <4.5% (>0.93%) for RMSE. While segmentation required 10 s including ∼6 s for user interaction, the smallest detectable difference was 0.24 l for algorithm measurements which was similar to manual measurements. Conclusions: This lung segmentation approach provided the necessary and sufficient precision and accuracy required for research and clinical studies.

60 APPLIED LIFE SCIENCES↗

Dynamic Aperture and Tolerances for PEP-X Ultimate Storage Ring Design

A lattice for the PEP-X ultimate storage ring light source, having 11 pm-rad natural emittance at a beam energy of 4.5 GeV at zero current, using 90 m of damping wiggler and fitting into the existing 2.2-km PEP-II tunnel, has been recently designed. Such a low emittance lattice requires very strong sextupoles for chromaticity correction, which in turn introduce strong non-linear field effects that limit the beam dynamic aperture. In order to maximize the dynamic aperture we choose the cell phases to cancel the third and fourth order geometric resonances in each 8-cell arc. Four families of chromatic sextupoles and six families of geometric (or harmonic) sextupoles are added to correct the chromatic and amplitude-dependent tunes. To find the best settings of the ten sextupole families, we use a Multi-Objective Genetic Optimizer employing elegant to optimize the beam lifetime and dynamic aperture simultaneously. Then we evaluate dynamic aperture reduction caused by magnetic field multipole errors, magnet fabrication errors and misalignments. A sufficient dynamic aperture is obtained for injection, as well as workable beam lifetime.

43 PARTICLE ACCELERATORS↗

High-order diamond differencing schemes for the Boltzmann Fokker-Planck equation in 3D Cartesian geometries

The Boltzmann Fokker-Planck, an approximate form of the linear Boltzmann equation is commonly used to treat efficiently the transport of charged particles in matter. This paper introduces the application of high-order diamond differencing schemes (HODD), specifically the DD1 and DD2 schemes which are 4- and 6-order accurate respectively, to handle the spatial discretization of that equation in 3D Cartesian geometries. The energy deposition solutions for the coupled transport of electrons and photons presented in this work shows that HODD, compared to classical DD scheme, provides correction to the oscillations and a reduced propensity to yield negative fluxes. They are useful tools to minimize local error, notably in regions with abrupt variations of the flux solution. They also can be used to reduced execution time by decreasing the needed number of voxels to obtain a fixed accuracy. On the tested benchmarks, the DD1 scheme is 87%- 92%-91% more accurate than the classical DD scheme for total, mean per-voxels and maximum deviation of energy deposition values respectively. For comparison, a calculation with 8 times more voxels, requiring roughly 2.5 times more time to execute, is 92%-90%-77% more accurate. (authors)

97 MATHEMATICS AND COMPUTING↗

THE KEPLER-19 SYSTEM: A TRANSITING 2.2 R{sub Circled-Plus} PLANET AND A SECOND PLANET DETECTED VIA TRANSIT TIMING VARIATIONS

We present the discovery of the Kepler-19 planetary system, which we first identified from a 9.3 day periodic transit signal in the Kepler photometry. From high-resolution spectroscopy of the star, we find a stellar effective temperature T{sub eff} = 5541 {+-} 60 K, a metallicity [Fe/H] = -0.13 {+-} 0.06, and a surface gravity log(g) = 4.59 {+-} 0.10. We combine the estimate of T{sub eff} and [Fe/H] with an estimate of the stellar density derived from the photometric light curve to deduce a stellar mass of M{sub *} = 0.936 {+-} 0.040 M{sub Sun} and a stellar radius of R{sub *} = 0.850 {+-} 0.018 R{sub Sun} (these errors do not include uncertainties in the stellar models). We rule out the possibility that the transits result from an astrophysical false positive by first identifying the subset of stellar blends that reproduce the precise shape of the light curve. Using the additional constraints from the measured color of the system, the absence of a secondary source in the high-resolution spectrum, and the absence of a secondary source in the adaptive optics imaging, we conclude that the planetary scenario is more than three orders of magnitude more likely than a blend. The blend scenario is independently disfavored by the achromaticity of the transit: we measure a transit depth with Spitzer at 4.5 {mu}m of 547{sup +113}{sub -110} ppm, consistent with the depth measured in the Kepler optical bandpass of 567 {+-} 6 ppm (corrected for stellar limb darkening). We determine a physical radius of the planet Kepler-19b of R{sub p} = 2.209 {+-} 0.048 R{sub Circled-Plus }; the uncertainty is dominated by uncertainty in the stellar parameters. From radial velocity observations of the star, we find an upper limit on the planet mass of 20.3 M{sub Circled-Plus }, corresponding to a maximum density of 10.4 g cm{sup -3}. We report a significant sinusoidal deviation of the transit times from a predicted linear ephemeris, which we conclude is due to an additional perturbing body in the system. We cannot uniquely determine the orbital parameters of the perturber, as various dynamical mechanisms match the amplitude, period, and shape of the transit timing signal and satisfy the host star's radial velocity limits. However, the perturber in these mechanisms has a period {approx}< 160 days and mass {approx}< 6 M{sub Jup}, confirming its planetary nature as Kepler-19c. We place limits on the presence of transits of Kepler-19c in the available Kepler data.

79 ASTRONOMY AND ASTROPHYSICS↗

Linear-Response Time-Dependent Embedded Mean-Field Theory

We present a time-dependent (TD) linear-response description of excited electronic states within the framework of embedded mean-field theory (EMFT). TD-EMFT allows for subsystems to be described at different mean-field levels of theory, enabling straightforward treatment of excited states and transition properties. We provide benchmark demonstrations of TD-EMFT for both local and nonlocal excitations in organic molecules, as well as applications to chlorophyll a, solvatochromic shifts of a dye in solution, and sulfur K-edge X-ray absorption spectroscopy (XAS). It is found that mixed-basis implementations of TD-EMFT lead to substantial errors in terms of transition properties; however, as previously found for ground-state EMFT, these errors are largely eliminated with the use of Fock-matrix corrections. These results indicate that TD-EMFT is a promising method for the efficient, multilevel description of excited-state electronic structure and dynamics in complex systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

BEYONDPLANCK IV. On end-to-end simulations in CMB analysis — Bayesian versus frequentist statistics

End-to-end simulations play a key role in the analysis of any high-sensitivity cosmic microwave background (CMB) experiment, providing high-fidelity systematic error propagation capabilities that are unmatched by any other means. In this paper, we address an important issue regarding such simulations, namely, how to define the inputs in terms of sky model and instrument parameters. These may either be taken as a constrained realization derived from the data or as a random realization independent from the data. We refer to these as posterior and prior simulations, respectively. We show that the two options lead to significantly different correlation structures, as prior simulations (contrary to posterior simulations) effectively include cosmic variance, but they exclude realization-specific correlations from non-linear degeneracies. Consequently, they quantify fundamentally different types of uncertainties. We argue that as a result, they also have different and complementary scientific uses, even if this dichotomy is not absolute. In particular, posterior simulations are in general more convenient for parameter estimation studies, while prior simulations are generally more convenient for model testing. Before BEYONDPLANCK, most pipelines used a mix of constrained and random inputs and applied the same hybrid simulations for all applications, even though the statistical justification for this is not always evident. BEYONDPLANCK represents the first end-to-end CMB simulation framework that is able to generate both types of simulations and these new capabilities have brought this topic to the forefront. The BEYONDPLANCK posterior simulations and their uses are described extensively in a suite of companion papers. In this work, we consider one important applications of the corresponding prior simulations, namely, code validation. Specifically, we generated a set of one-year LFI 30 GHz prior simulations with known inputs and we used these to validate the core low-level BEYONDPLANCK algorithms dealing with gain estimation, correlated noise estimation, and mapmaking.

79 ASTRONOMY AND ASTROPHYSICS↗

Spherical collapse model with non-clustering dark energy

We investigate a spherical overdensity model for the non-clustering dark energy (DE) with the constant equation of state, ω{sub de} in a flat universe. In this case, the exact solution for the evolution of the scale factor is obtained for general ω{sub de}. We also obtain the exact (when ω{sub de} = −1/3) and the approximate (when ω{sub de}≠−1/3) solutions for the ratio of the overdensity radius to its value at the turnaround epoch (y≡R/R{sub ta}) for general cosmological parameters. Also the exact and approximate solutions of the overdensity at the turnaround epoch ζ = (ρ{sub cluster}/ρ{sub m})|{sub z} {sub =} {sub z{sub t{sub a}}} are obtained for general ω{sub de}. Thus, we are able to obtain the non-linear overdensity Δ≡1+δ{sub NL} = ζ(x/y){sup 3} at any epoch for the given DE model. The non-linear overdensity at the virial epoch Δ{sub vir} = ζ(x{sub vir}/y{sub vir}){sup 3} is obtained by using the virial theorem and the energy conservation. The non-linear overdensity of every DE model converges to that of the Einstein de Sitter universe Δ{sub vir}{sup EdS} = 18π{sup 2}((1/2π)+(3/4)){sup 2} ≅ 147 when z{sub vir} increases. We find that the observed quantities at high redshifts are insensitive to the different ω{sub de} models. The low-redshift cluster (z{sub vir} ∼ 0.04, i.e., z{sub ta} ∼ 0.7) shows the most model dependent feature and it should be a suitable object for testing DE models. Also as Ω{sub M}{sup 0} increases, the model dependence of the observed quantities decreases. The error in the approximate solutions is at most 2% for a wide range of the parameter space. Even though the analytic forms of y and ζ are obtained for the constant ω{sub de}, they can be generalized to the slowly varying ω{sub de}. Thus, these analytic forms of the scale factor, y, and ζ provide a very accurate and useful tool for measuring the properties of DE.

79 ASTRONOMY AND ASTROPHYSICS↗

Spectral density reconstruction with Chebyshev polynomials

Accurate calculations of the spectral density in a strongly correlated quantum many-body system are of fundamental importance to study its dynamics in the linear response regime. Typical examples are the calculation of inclusive and semiexclusive scattering cross sections in atomic nuclei and transport properties of nuclear and neutron star matter. Integral transform techniques play an important role in accessing the spectral density in a variety of nuclear systems. However, their accuracy is in practice limited by the need to perform a numerical inversion which is often ill-conditioned. Here, in the present work we extend a recently proposed quantum algorithm which circumvents this problem. We show how to perform controllable reconstructions of the spectral density over a finite energy resolution with rigorous error estimates. An appropriate expansion in Chebyshev polynomials allows for efficient simulations also on classical computers. We apply our idea to obtain the local density of states for graphene in a magnetic field as a proof of principle. This paves the way for future applications in nuclear and condensed matter physics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development and evaluation of a method of calibrating medical displays based on fixed adaptation

Purpose: The purpose of this work was to develop and evaluate a new method for calibration of medical displays that includes the effect of fixed adaptation and by using equipment and luminance levels typical for a modern radiology department. Methods: Low contrast sinusoidal test patterns were derived at nine luminance levels from 2 to 600 cd/m{sup 2} and used in a two alternative forced choice observer study, where the adaptation level was fixed at the logarithmic average of 35 cd/m{sup 2}. The contrast sensitivity at each luminance level was derived by establishing a linear relationship between the ten pattern contrast levels used at every luminance level and a detectability index (d′) calculated from the fraction of correct responses. A Gaussian function was fitted to the data and normalized to the adaptation level. The corresponding equation was used in a display calibration method that included the grayscale standard display function (GSDF) but compensated for fixed adaptation. In the evaluation study, the contrast of circular objects with a fixed pixel contrast was displayed using both calibration methods and was rated on a five-grade scale. Results were calculated using a visual grading characteristics method. Error estimations in both observer studies were derived using a bootstrap method. Results: The contrast sensitivities for the darkest and brightest patterns compared to the contrast sensitivity at the adaptation luminance were 37% and 56%, respectively. The obtained Gaussian fit corresponded well with similar studies. The evaluation study showed a higher degree of equally distributed contrast throughout the luminance range with the calibration method compensated for fixed adaptation than for the GSDF. The two lowest scores for the GSDF were obtained for the darkest and brightest patterns. These scores were significantly lower than the lowest score obtained for the compensated GSDF. For the GSDF, the scores for all luminance levels were statistically separated from the average value; three were lower and two were higher. For the compensated GSDF, three of the scores could not be separated from the average value. Conclusions: An observer study using clinically relevant displays and luminance settings has demonstrated that the calibration of displays according to the GSDF causes the perceived contrast to be unevenly distributed when using displays with a high luminance range. As the luminance range increases, the perceived contrast in the dark and bright regions will be significantly lower than the perceived contrast in the middle of the luminance range. A new calibration method that includes the effect of fixed adaptation was developed and evaluated in an observer study and was found to distribute the contrast of the display more evenly throughout the grayscale than the GSDF.

60 APPLIED LIFE SCIENCES↗

Globally optimal interferometry with lossy twin Fock probes

Parity or quadratic spin (e.g., J z 2 ) readouts of a Mach–Zehnder (MZ) interferometer probed with a twin Fock (TF) input state allow saturating the optimal sensitivity attainable among all mode-separable states with a fixed total number of particles but only when the interferometer phase θ is near zero. When more general Dicke state probes are used, the parity readout saturates the quantum Fisher information (QFI) at θ = 0, whereas better-than-standard quantum limit performance of the J z 2 readout is restricted to an o ( N ) occupation imbalance. We show that a method of moments readout of two quadratic spin observables J z 2 and J + 2 + J − 2 is globally optimal for Dicke state probes; i.e., the error saturates the QFI for all θ . In the lossy setting, we derive the time-inhomogeneous Markov process describing the effect of particle loss on TF states, showing that the method of moments readout of four at-most-quadratic spin observables is sufficient for globally optimal estimation of θ when two or more particles are lost. The analysis culminates in a numerical calculation of the QFI matrix for distributed MZ interferometry on the four-mode state | N 4 , N 4 , N 4 , N 4 〉 and its lossy counterparts, showing that an advantage for the estimation of any linear function of the local MZ phases θ 1 and θ 2 (compared to independent probing of the MZ phases by two copies of | N 4 , N 4 〉 ) appears when more than one particle is lost.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Qweak experiment: a precision measurement of the proton's weak charge

The Qweak experiment will conduct the first precision measurement of the weak charge of the proton, Q{sub W}{sup p}, at Jefferson Laboratory, building on the technical advances that have been made in the laboratory's parity-violation program and using the results of earlier measurements to constrain hadronic corrections. When the results from this measurement are combined with atomic-parity violation and other PVES measurements the weak charges of the 'up' and 'down' quarks can be extracted. The experiment is basically a measurement of the parity-violating longitudinal analyzing power in e-p elastic scattering at Q{sup 2} = 0.026 (GeV/c){sup 2} employing 150 {mu}A's of 85% polarized electrons on a 0.35 m long liquid hydrogen target. The experiment will determine the weak charge of the proton with about 4.1% combined statistical and systematic errors. This corresponds to constraints on parity violating new physics at a mass scale of 2.3 TeV at the 95% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Effects of Gamma Ray Integrated Dose on a Commercial 65-nm SRAM Device

Here this work shows that the static random access memory (SRAM) error rate for a commercial 65-nm device in a dose rate environment can be highly dependent upon the integrated dose (dose rate × pulse duration). While the typical metric for such testing is dose rate upset (DRU) level in rad(Si)/s, a series of dose rate experiments at Little Mountain Test Facility (LMTF) shows dependence on the integrated dose. The error rate is also found to be dependent on the core voltage, and the preradiation value of the bits. We believe that these effects are explained by a well charge depletion caused by gamma ray photocurrent.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗