Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNET SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

H0538 + 608 - A bright AM Herculis-type X-ray source

The discovery of an AM Herculis-type magnetic variable, an accreting binary system that contains a magnetic white dwarf and a late-type companion, is reported. The proposed optical counterpart to the detected X-ray source exhibits all the optical emission characteristics of its class: circular polarization, strongly modulated brightness variations, intense flickering on time scales of seconds, historical 'low states', and intense emission lines, including very strong lines of He II. The modulations in the polarization and the photometric magnitude suggest an orbital period of 3.1 + or -0.2 hr.

Remillard, R. A.↗

Status of magnetic suspension technology

The reasons for the continuing interest in the Magnetic Suspension and Balance System (MSBS) are highlighted. Typical problems that can arise because of model-support interference in a transonic wind tunnel are shown to illustrate the need for MSBS. The two magnetic suspension systems in operation at Langley are the only ones active in the U.S. One of these systems is the 13 inch MSBS which was borrowed from the Air Force Arnold Engineering Development Center. The other system is the 6 inch MSBS which was developed by MIT Aerophysics Laboratory with NASA and DOD funding. Each of these systems is combined with a subsonic wind tunnel. Ongoing research in both of these systems is covered. Last year, Madison Magnetics, Inc., completed a contractual design and cost study utilizing some advance concepts for a large MSBS which would be compatible with an 8 foot transonic wind tunnel and the highlights of the study are presented. Sverdrup Technology, Inc., recently performed a study under contract for Langley on the potential usefulness to the aerospace industry of a proposed large MSBS combined with a suitable transonic wind tunnel. The results of that study are discussed. Langley has partially funded the MSBS work at the University of Southampton for about 6 years under a grant arrangement and the major results are summarized.

Boyden, Richmond P.↗

Magnetic-Flux-Compression Cooling Using Superconductors

Proposed magnetic-flux-compression refrigeration system produces final-stage temperatures below 4.2 K. More efficient than mechanical and sorption refrigerators at temperatures in this range. Weighs less than comparable liquid-helium-cooled superconducting magnetic refrigeration systems operating below 4.2 K. Magnetic-flux-compression cooling stage combines advantages of newly discovered superconductors with those of cooling by magnetization and demagnetization of paramagnetic salts.

Strayer, Donald M.↗

Measuring the magnetic fields of Jupiter and the outer solar system

The vector helium magnetometer, one of the Pioneer-Jupiter experiments, has measured the magnetic field of Jupiter and the interplanetary magnetic field in the outer solar system. The comprehensive scientific objectives of the investigations are explained and are then translated into the major instrument requirements. The principles of operation of the magnetometer, which involve the optical pumping of metastable helium, are discussed and the Pioneer instrument is described. The in-flight performance of the magnetometer is discussed and principal scientific results obtained thus far by the Pioneer investigation are summarized.

Smith, E. J.↗

Characterization of Losses in Superconducting Radio-Frequency Cavities by Combined Temperature and Magnetic Field Mapping

Superconducting radio-frequency (SRF) cavities are one of the fundamental building blocks of modern particle accelerators. To achieve the highest quality factors (10 10 -10 11 ), SRF cavities are operated at liquid helium temperatures. Magnetic flux trapped on the surface of SRF cavities during cool-down below the critical temperature is one of the leading sources of residual RF losses. Instruments capable of detecting the distribution of trapped flux on the cavity surface are in high demand in order to better understand its relation to the cavity material, surface treatments and environmental conditions. We have designed, developed, and commissioned two novel diagnostic tools to measure the distribution of trapped flux at the surface of SRF cavities. One is a magnetic field scanning system (MFSS) which uses cryogenic Hall probes and anisotropic magnetoresistance sensors that fit the contour of a 1.3 GHz cavity. The second setup is a stationary, combined magnetic and temperature mapping system which uses AMR sensors and carbon resistor temperature sensors, covering the surface of a 3 GHz SRF cavity. The MFSS system revealed a non-uniform distribution of trapped flux on the cavities' surface, dependent on the magnitude of the applied magnetic field during field-cooling below the critical temperature. The MFSS shows that magnetic field scanning as a function of the RF field indicates redistribution of trapped flux at some locations. About ~ 33% of hot-spots observed by temperature mapping during high power RF tests overlapped with the high B-field spots. Almost all high B-field spots observed after field-cool were found to be overlapped on grain boundaries. A clear correlation between the hot- spot formed after quench and local trapped flux was found, providing insight on the RF dissipation of trap vortices. The combined B&T map system showed that the T-map system is capable of detecting hot-spots and quench location on the surface of the 3 GHz SRF cavity. Different distribution of trapped flux was measured after different cool-down and residual B-field, but, no variation in magnetic field distribution was observed during quench, possibly due to magnetic sensors being far from the quench location.

Parajuli, Ishwari↗

High pressure synthesis and magnetic studies of quasi one dimensional systems Sr(n-1)Cu(n+1)O(2n) (n=3,5)

SrCu2O3 and Sr2Cu3O5 containing two-leg and three-leg S = 1/2 ladders made of antiferromagnetic Cu-O-Cu linear bonds, respectively, were synthesized at high pressure, and their crystallographic and magnetic properties were investigated. Both susceptibility and T(1) data of NMR (nuclear magnetic resonance) revealed the existence of a large spin gap only for SrCu2O3. Superconductivity, which had been predicted theoretically for carrier-doped SrCu2O3 could not be realized although partial substitution of La(3+) for Sr(2+) seemed to be carried out successfully. Electron carriers injected seems to remain localized.

Azuma, M.↗

Infrared Imaging System for Studying Brain Function

A proposed special-purpose infrared imaging system would be a compact, portable, less-expensive alternative to functional magnetic resonance imaging (fMRI) systems heretofore used to study brain function. Whereas a typical fMRI system fills a large room, and must be magnetically isolated, this system would fit into a bicycle helmet. The system would include an assembly that would be mounted inside the padding in a modified bicycle helmet or other suitable headgear. The assembly would include newly designed infrared photodetectors and data-acquisition circuits on integrated-circuit chips on low-thermal-conductivity supports in evacuated housings (see figure) arranged in multiple rows and columns that would define image coordinates. Each housing would be spring-loaded against the wearer s head. The chips would be cooled by a small Stirling Engine mounted contiguous to, but thermally isolated from, the portions of the assembly in thermal contact with the wearer s head. Flexible wires or cables for transmitting data from the aforementioned chips would be routed to an integrated, multichannel transmitter and thence through the top of the assembly to a patch antenna on the outside of the helmet. The multiple streams of data from the infrared-detector chips would be sent to a remote site, where they would be processed, by software, into a three-dimensional display of evoked potentials that would represent firing neuronal bundles and thereby indicate locations of neuronal activity associated with mental or physical activity. The 3D images will be analogous to current fMRI images. The data would also be made available, in real-time, for comparison with data in local or internationally accessible relational databases that already exist in universities and research centers. Hence, this system could be used in research on, and for the diagnosis of response from the wearer s brain to physiological, psychological, and environmental changes in real time. The images would also be stored in a relational database for comparison with corresponding responses previously observed in other subjects.

Mintz, Frederick↗

Non-proportionality of magnetic anisotropy and damping in CoFeB/MgO-based systems

We study the relationship between anisotropy K and damping α in MgO/CoFeB/Ta/CoFeB/MgO/cap films using vector network analyzer ferromagnetic resonance. Capping the stack with Ta and changing the thickness of the top MgO layer allow us to create significant variations in anisotropy while keeping the thickness and process conditions of the magnetic layer constant. The change in anisotropy can be attributed to the degradation of the CoFeB/MgO interface due to Ta intermixing with MgO upon deposition. This hypothesis is supported by measurements of similar samples with the bottom MgO thickness varied instead, which exhibit no significant change in anisotropy. This method of varying K allows identifying a regime where a spin reorientation transition occurs while α remains constant, proving the non-proportionality of K and α in perpendicular CoFeB/MgO systems. The effects of changing the capping layer material, notably Ru, are also discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Impurity Magnetic Susceptibility of Semiconductors in the Case of Direct Exchange Interaction in the Ising Model

The numerical simulation was applied to study the temperature dependence of the impurity magnetic susceptibility. The direct exchange interaction of the impurity magnetic moments randomly distributed in space was considered within the Ising model. When the temperature in a system decreases, the magnetic susceptibility behavior in this system ceases to comply with the Curie law, which is associated with the formation of a spin glass phase. It is shown that the expression of the preexponential factor in the formula for the direct exchange interaction considerably influences the temperature dependence of the magnetic susceptibility only in the case of ferromagnetic exchange.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic structure of few-nucleon systems at high momentum transfers in a chiral effective field theory approach

The five low-energy constants (LECs) in the electromagnetic current derived in chiral effective field theory ( χ EFT ) up to one loop are determined by a simultaneous fit to the A = 2 – 3 nuclei magnetic moments and to the deuteron magnetic form factor and threshold electrodisintegration at backward angles over a wide range of momentum transfers. The resulting parametrization then yields predictions for the 3 He/ 3 H magnetic form factors in excellent accord with the experimental values for momentum transfers ranging up to ≈0.8 GeV/c, beyond the expected regime of validity of the χEFT approach. The calculations are based on last-generation two-nucleon interactions including high orders in the chiral expansion and derived by Entem, Machleidt, and Nosyk [Phys. Rev. C 96, 024004 (2017)] and by Piarulli et al. [Phys. Rev. C 94, 054007 (2016)], using different χEFT formulations. In the A = 3 calculations, (chiral) three-nucleon interactions are also accounted for. The model dependence resulting from these different formulations of the interactions is found to be mild for momentum transfer below ≈0.8 GeV/c . Further, an analysis of the convergence of the chiral expansion is also provided.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improved inertial control for permanent magnet synchronous generator wind turbine generators

With increasing integrations of large‐scale systems based on permanent magnet synchronous generator wind turbine generators (PMSG‐WTGs), the overall inertial response of a power system will tend to deteriorate as a result of the decoupling of rotor speed and grid frequency through the power converter as well as the scheduled retirement of conventional synchronous generators. Thus, PMSG‐WTGs can provide value to an electric grid by contributing to the system's inertial response through the inherent kinetic energy stored in their rotating masses and fast power converter control. In this study, an improved inertial control method based on the maximum power point tracking operation curve is introduced to enhance the overall frequency support capability of PMSG‐WTGs in the case of large supply–demand imbalances. Moreover, this method is implemented in the CART2‐PMSG integrated model in MATLAB/Simulink to investigate its impact on the wind turbine's structural loads during the inertial response process. Simulation results indicate that the proposed method can effectively reduce the frequency nadir, arrest the rate of change of frequency, and alleviate the secondary frequency dip while imposing no negative impact on the major mechanical components of the wind turbine.

Wu, Ziping↗

Effect of bias application to plasma density in weakly magnetized inductively coupled plasma

Independent control of the ion flux and energy can be achieved in a dual frequency inductively coupled plasma (ICP) system. Typically, the plasma density is controlled by the high-frequency antenna radio-frequency (RF) power and the ion energy is controlled by the low-frequency bias RF power. Increasing the bias power has been known to cause a decrease in the plasma density in capacitively coupled discharge systems as well as in ICP systems. However, an applied axial magnetic field was found to sustain or increase the plasma density as bias power is increased. Measurements show higher electron temperatures but lower plasma densities are obtained in ordinary ICP systems than in magnetized ICP systems under the same neutral gas pressure and RF power levels. Explanations for the difference in the behavior of plasma density with increasing bias power are given in terms of the difference in the heating mechanism in ordinary unmagnetized and magnetized ICP systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design of CRM AC/DC Converter for Very High-Frequency High-Density WBG-Based 6.6kW Bidirectional On-Board Battery Charger

The wide-band-gap (WBG) devices based 6.6 kW bidirectional on-board charger (OBC) system for plug-in electric vehicles (PEVs) is recently developed. With the proposed novel variable DC-link voltage system architecture, high frequency soft switching operation, and integrated magnetics, the OBC system becomes more compact and more efficient compared to a Sibased counterpart. The design considerations of the AC/DC stage are introduced in this paper including the evaluation of 1.2 kV SiC MOSFETs; the zero-voltage-switching (ZVS) extension function for the line-cycle ZVS operation; and the novel universal control strategy for both the rectifier mode and the inverter mode. The prototype of the AC/DC stage is built which achieves 98.5% efficiency at higher than 300 kHz switching frequency. Finally, the complete 6.6 kW OBC system using both SiC and GaN devices is demonstrated with 37 W/in3 power density and above 96% efficiency.

Liu, Zhengyang↗

Measuring the Magnetic Center Behavior of an ILC Superconducting Quadrupole Prototype

The main linacs of the proposed International Linear Collider (ILC) consist of superconducting cavities operated at 2K. The accelerating cavities are contained in a contiguous series of cryogenic modules that also house the main linac quadrupoles, thus the quadrupoles also need to be superconducting. In an early ILC design, these magnets are about 0.6 m long, have cos (2{theta}) coils, and operate at constant field gradients up to 60 T/m. In order to preserve the small beam emittances in the ILC linacs, the e+ and e- beams need to traverse the quadrupoles near their magnetic centers. A quadrupole shunting technique is used to measure the quadrupole alignment with the beams; this process requires the magnetic centers move by no more than about 5 micrometers when their strength is changed. To determine if such tight stability is achievable in a superconducting quadrupole, we at SLAC measured the magnetic center motions in a prototype ILC quadrupole built at CIEMAT in Spain. A rotating coil technique was used with a better than 0.1 micrometer precision in the relative field center position, and less than a 2 micrometer systematic error over 30 minutes. This paper describes the warm-bore cryomodule that houses the quadrupole in its Helium vessel, the magnetic center measurement system, the measured center data and strength and harmonics magnetic data.

43 PARTICLE ACCELERATORS↗

Frustration Properties of the 1D Ising Model

We analyze frustration properties of the Ising model for a 1D monatomic equidistant lattice in an external uniform magnetic field considering exchange interactions of atomic spins at the sites of the first (nearest) and second neighbors. Exact analytic expressions for thermodynamic and magnetic characteristics of the system, as well as for the Fourier transform of the pair spin–spin correlation function and magnetic diffused scattering wavevectors, were obtained by the method of the Kramers–Wannier transfer matrix considering the exchange interaction between spins at the nearest-neighbor sites in an external magnetic field, as well as the exchange interaction between spins at the second-neighbor sites in zero magnetic field. The criteria for the emergence of magnetic frustration in the presence of competition not only between exchange-interaction energies, but also between these energies and the external magnetic field energy are formulated. The frustration points and the values of frustration magnetic fields depending on the magnitudes and signs of the exchange interaction are determined. The distinguishing features of this model in the frustration regime and its vicinity are analyzed. The set of characteristic features inherent in observables for systems with magnetic frustrations is considered and analyzed. It is shown that the inclusion of competing exchange interactions at the first- and second-neighbor sites makes it possible to describe the behavior of the magnetic diffused scattering wavevector for commensurate, incommensurate, and lock-in structures.

74 ATOMIC AND MOLECULAR PHYSICS↗

A Novel Integrated Magnetic Structure Based DC/DC Converter for Hybrid Battery/Ultracapacitor Energy Storage Systems

This manuscript focuses on a novel actively controlled hybrid magnetic battery/ultracapacitor based energy storage system (ESS) for vehicular propulsion systems. A stand-alone battery system might not be sufficient to satisfy peak power demand and transient load variations in hybrid and plug-in hybrid electric vehicles (HEV, PHEV). Active battery/ultracapacitor hybrid ESS provides a better solution in terms of efficient power management and control flexibility. Moreover, the voltage of the battery pack can be selected to be different than that of the ultracapacitor, which will result in flexibility of design as well as cost and size reduction of the battery pack. In addition, the ultracapacitor bank can supply or recapture a large burst of power and it can be used with high C-rates. Hence, the battery is not subjected to supply peak and sharp power variations, and the stress on the battery will be reduced and the battery lifetime would be increased. Utilizing ultracapacitor results in effective capturing of the braking energy, especially in sudden braking conditions.

25 ENERGY STORAGE↗

Large magnetic anisotropy of a decorated spin-chain system K 2 Co 3 (MoO 4 ) 3 (OH) 2

The magnetic structure of K 2 Co 3 (MoO 4 ) 3 (OH) 2 is studied in detail. The material has a half-sawtooth one-dimensional (1-D) structure containing two unique Co 2+ ions, one in the chain backbone and one on the apex of the sawtooth creating a series of isosceles triangles along the b-axis. These triangles can be a source of magnetic frustration. The ability to grow large single crystals enables detailed magnetic measurements with the crystals oriented in a magnetic field along the respective axes. It has a Curie–Weiss temperature θ CW of 5.3(2) K with an effective magnetic moment of 4.8(3)μ B /Co. The material is highly anisotropic with a sharp antiferromagnetic ordering transition at 7 K with a metamagnetic transition at 2 kOe. Neutron diffraction was used to determine the magnetic structure and revealed a magnetic structure with canted spins along the backbone of the chain while spins along the sawtooth caps maintained a colinear orientation, arranging antiferromagnetically relative to the backbone spins. In conclusion, the parallel chains arrange antiferromagnetically relative to each other along the c-axis and ferromagnetically along the a-axis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗