Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Pulsed spallation neutron spectroscopy of low dimensional magnets: past, present, and future

The early 1990s saw the first useful application of pulsed neutron spectroscopy to the study of excitations in low dimensional magnetic systems, with Roger Cowley as a key participant in important early experiments. Since that time the technique has blossomed as a powerful tool utilizing vastly improved neutron instrumentation coupled with more powerful pulsed sources. In this work, we review representative experiments illustrating some of the fascinating physics that has been revealed in quasi-one and two dimensional systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Progress Toward a Compact 0.05 K Magnet Refrigerator Operating from 10 K

Much of the most interesting information regarding our universe is hidden in the sub-millimeter, infrared, and x-rays bands of the spectrum, to which our atmosphere is largely opaque. Thus, missions exploring these bands are a very important part of NASA s Space Science program. Coincidentally, the most sensitive detectors in these spectral regions operate at extremely low temperatures, typically 0.05 - 0.10 K. Generally these temperatures will be achieved using magnetic refrigerators, also know as Adiabatic Demagnetization Refrigerators, or ADRs. Current ADRs, such as the one used in the XRS-II instrument on the Astro-E2 satellite, use a single-stage to cool detectors from 1.3 K to 0.06 K. The ADR is designed so that it can absorb the heat on the detector stage for at least 24 hours before it must stop, warm up to the helium bath temperature (1.3 K), and dump the accumulated heat. Future detector arrays will be much larger and will have higher heat dissipation. Furthermore, future missions will use mechanical cryocoolers to provide upper stage cooling, but they can only reach 4 - 10 K. Trying to scale heavy (-15 kg) single stage ADRs up to the higher heat loads and higher heat rejection temperatures required leads to unacceptably large systems. The GSFC Cryogenics Branch has developed the Continuous ADR (CADR) to solve this problem. The CADR consists of a series of ADR stages that sequentially pass heat from the load up to the high temperature heat sink. The stage connected to the load remains at a constant temperature. The continuous stage effectively decouples detector operation from ADR operation, allowing the ADR stages to be cycled much more rapidly. Rapid cycling leads to higher cooling power density. The cascading, multistage arrangement allows the magnetic refrigerant of each stage to be optimized for its own temperature swing. In the past year, we have made good progress toward a 0.05 to 10K system. A four-stage system that operates from 4.2 K was demonstrated. Magnetic shielding was added to eliminate inter-stage coupling. Improvements were made to superconducting and passive gas-gap heat switches. A second type of passive gas gap switch, one meant for use at higher temperature, was demonstrated. The presentation will focus primarily on these recent design improvements, and on the challenges that remain on the progress toward a system that will operate from 10 K or higher.

Canavan, Edgar↗

Availability of previously lost data and metadata from the Apollo Lunar Surface Experiments Package (ALSEP)

Fourteen types of geophysical instruments deployed at the Apollo 12, 14, 15, 16, and 17 sites by the astronauts for long-term observation were collectively called the Apollo Lunar Surface Experiments Package (ALSEP). These instruments were active from the times of their deployment (November 1969–December 1972) to September 1977. At the conclusion of the experiments, the raw instrument data received from the Moon prior to March 1976 were left unarchived. Portions of the data processed by the principal investigators (PIs) of these experiments had been archived at the NASA Space Science Data Coordinated Archive (NSSDCA) in various formats. The unarchived data, residing then on open-reel magnetic tapes, became lost in the decades since, along with much of the metadata (the supporting documents for these data). We have recently recovered 440 of the previously lost tapes, containing raw ALSEP instrument data from April through June of 1975. Here we describe the data extracted from these tapes and summarize the data products generated for archiving at the NASA Planetary Data System (PDS) and NSSDCA, along with their historical narrative. In addition, we have reformatted many of the datasets delivered to NSSDCA by the PIs in the 1970s for archiving at the PDS. Finally, we have compiled an online searchable repository of ALSEP-related documents by optically scanning tens of thousands of pages of them kept at the Lunar and Planetary Institute in Texas.

S. Nagihara↗

An integrated development facility for the calibration of low-energy charged particle flight instrumentation

A system was developed for the calibration and development of thermal ion instrumentation. The system provides an extended beam with usable current rates, approx. 1 pA/sq cm, at beam energies as low as 1 eV, with much higher values available with increasing energy. A tandem electrostatic and variable geometry magnetic mirror configuration within the ion source optimizes the use of the ionizing electrons. The system is integrated under microcomputer control to allow automatic control and monitoring of the beam energy and composition and the mass and angle-dependent response of the instrument under test. The system is pumped by a combination of carbon vane and cryogenic sorption roughing pumps and ion and liquid helium operating pumps.

Biddle, A. P.↗

Techniques for the Installation of Internal Fiber Optic Instrumentation on an 11-Inch Hybrid Motor Test Bed

The recent developments in Fabry-Perot fiber optic instruments have resulted in accurate transducers with some of the physical characteristics required for use in obtaining internal data from solid rocket motors. These characteristics include small size, non-electrical excitation, and immunity to electro-magnetic interference. These transducers have not been previously utilized in this environment due to the high temperatures typically encountered. A series of tests were conducted using a 1 1-Inch Hybrid test bed to develop installation techniques that will allow the fiber optic instruments to survive and obtain data for a short period of time following the motor ignition. The installation methods developed during this test series have the potential to allow data to be acquired in the motor chamber, propellant bore, and nozzle during the ignition transient. These measurements would prove to be very useful in the characterization of current motor designs and provide insight into the requirements for further refinements. The process of developing these protective methods and the installation techniques used to apply them is summarized.

Cornelius, Michael↗

Progress Towards Microcalorimeter Gamma Spectroscopy Analysis for Nuclear Fuel Separations

The High Efficiency and Resolution Microcalorimeter Spectrometer, 400 pixels (HERMES-400) is an ultra-high resolution gamma-ray spectrometer at Idaho National Laboratory’s Materials and Fuels Complex. HERMES-400 is intended to enable precise nondestructive analysis of advanced fuel cycle materials. Key upgrades and repairs of the instrument were performed this year to improve performance. First, the fourth and final microcalorimeter detector module was installed, meeting the milestone for its integration into the system. Operation with all four modules enables higher detector efficiency than any previous microcalorimeter gamma-ray system. Second, a thinner magnetic shield was installed. This shields the sensitive microcalorimeter pixels from stray magnetic fields while allowing transmission of lower-energy gamma rays, which are important to isotopic analysis. Finally, the cryostat, which provides cooling of the modules to their operating temperature, was found to have a helium coolant leak, which was repaired. HERMES-400 is in a stable state to perform repeated, long-term gamma-ray measurements with good detector efficiency and energy resolution. In FY25, irradiated TRISO fuel and salts from advanced electrochemical recycling techniques are candidates for microcalorimeter measurements. A final upgrade of the magnetic shielding and vibration damping of the system is also planned to maximize the system performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light-narrowed optically pumped M{sub x} magnetometer with a miniaturized Cs cell

We demonstrate a way of operating an optically pumped magnetometer with miniaturized cesium cell using the light-narrowing effect. The magnetometer setup shows improvement of shot-noise-limited sensitivity (42 fT/{radical}(Hz) in a cell of only 9.3 mm{sup 3} volume) due to the suppression of spin-exchange relaxation to a large extent and the use of a strikingly increased fraction of alkali-metal atoms for signal generation, working even in {mu}T magnetic fields, by using only a single high-intensity laser beam both for pumping and probing of atomic spins.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a compliant passive magnetic bearing for use in SIRTF's Tertiary Mirror Assembly

A proposed baseline design for the Space Infrared Telescope Facility includes a Tertiary Mirror Assembly (TMA) which selectively redirects the telescope's converging science beam to each of several instruments. The TMA's mirror rotates on an axis coincident with the beam's axis, and is held steady during observation by a kinematic mount. A bearing has been designed whose compliance causes minimal interference with the precision of the kinematic mount, and which is well suited to the particular requirements of a cryogenic satellite such as SIRTF. The bearing suspends its rotor by taking advantage of the repulsion between a superconductor and a magnet. It potentially eliminates problems associated with mechanical bearings that arise in similar applications, such as lubricant loss or failure, bearing wear, and sensitivity to particulates, and does so without imposing the thermal load of a bearing heater or active magnetic bearing. The bearing shows promise of offering an alternative to ball bearings in cryogenic applications where some compliance is acceptable or advantageous.

Cannon, David M.↗

The Sun at high spatial resolution: The physics of small spatial structures in a magnetized medium

An attempt is made to provide a perspective on the problem of spatial structuring on scales smaller than can presently be directly and regularly observed from the ground or with which current space-based instrumentation can be anticipated. There is abundant evidence from both observations and theory that such spatial structuring of the solar outer atmosphere is ubiquitous not only on the observed scales, but also on spatial scales down to (at least) the subarcsecond range. This is not to say that the results to be obtained from observations on these small scales can be anticipated: quite the opposite. What is clear instead is that many of the classic problems of coronal and chromospheric activity - involving the basic dissipative nature of magnetized plasmas - will be seen from a novel perspective at these scales, and that there are reasons for believing that dynamical processes of importance to activity on presently-resolved scales will themselves begin to be resolved on the sub-arcsecond level. Since the Sun is the only astrophysical laboratory for which there is any hope of studying these processes in any detail, this observatioinal opportunity is an exciting prospect for any student of magnetic activity in astrophysics.

Rosner, R. T.↗

Polar Magnetic Field Experiment

This grant covers the initial data reduction and analysis of the magnetic field measurements of the Polar spacecraft. At this writing data for the first three years of the mission have been processed and deposited in the key parameter database. These data are also available in a variety of time resolutions and coordinate systems via a webserver at UCLA that provides both plots and digital data. The flight software has twice been reprogrammed: once to remove a glitch in the data where there were rare collisions between commands in the central processing unit and once to provide burst mode data at 100 samples per second on a regular basis. The instrument continues to function as described in the instrument paper (1.1 in the bibliography attached below). The early observations were compared with observations on the same field lines at lower altitude. The polar magnetic measurements also proved to be most useful for testing the accuracy of MHD models. WE also made important contributions to study of waves and turbulence.

Russell, C. T.↗

A Quench Detection and Monitoring System for Superconducting Magnets at Fermilab

A quench detection system was developed for protecting and monitoring the superconducting solenoids for the Muon-to-Electron Conversion Experiment (Mu2e) at Fermilab. The quench system was designed for a high level of dependability and long-term continuous operation. It is based on three tiers: Tier-I, FPGA-based Digital Quench Detection (DQD); Tier-II, Analog Quench Detection (AQD); and Tier-3, the quench controls and data management system. The Tier-I and Tier-II are completely independent and fully redundant systems. The Tier-3 system is based on National Instruments (NI) C-RIO and provides the user interface for quench controls and data management. It is independent from Tiers I & II. The DQD provides both quench detection and quench characterization (monitoring) capability. Both DQD and AQD have built-in high voltage isolation and user programmable gains and attenuations. The DQD and AQD also includes user configured current dependent thresholding and validation times. A 1 st article of the three-tier system was fully implemented on the new Fermilab magnet test stand for the HL-LHC Accelerator Up-grade Project (AUP). It successfully provided quench protection and monitoring (QPM) for a cold superconducting bus test in November 2020. The Mu2e quench detection design has since been implemented for production testing of the AUP magnets. A detailed description of the system along with results from the AUP superconducting bus test will be presented.

monitoring↗

On entropy determination from magnetic and calorimetric experiments in conventional giant magnetocaloric materials

In this work, we discuss measurement protocols for the determination of the magnetic entropy change associated with first-order magneto-structural transitions from both magnetization and calorimetric experiments. Furthermore, the Cu-doped Ni 2 MnGa Heusler alloy with a first-order magneto-structural phase transition is used as a case study to illustrate how commonly-used magnetization measurement protocols result in spurious entropy evaluations. Two magnetization measurement protocols which allow for the accurate assessment of the magnetic entropy change across first-order magneto-structural transitions are presented. In addition, calorimetric measurements were performed to validate the results from the magnetization measurements. Self-consistent results between themagnetization and calorimetric measurements were obtained when the non-equilibrium thermodynamic state was carefully handled. Such methods could be applicable to other systems displaying giant magnetocaloric effects caused by first-order phase transitions with magnetic and thermal hysteresis.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Preface to the Proceedings of the 25th Topical Conference on High-Temperature Plasma Diagnostics

The 25th Topical Conference on High-Temperature Plasma Diagnostics (HTPD 2024) was held in Asheville, NC, USA, at the Renaissance Asheville Downtown Hotel from 21 to 25 April 2024. This biennial conference brings together scientists and engineers from a variety of fields, including magnetic confinement fusion, inertial confinement fusion, space plasmas, astrophysics, and industrial applications, to discuss mutual problems in the development of instrumentation and experimental techniques for the characterization of high-temperature plasmas. As the 25th meeting, HTPD 2024 represents ∼50 years of ongoing international collaboration on these topics.

Biewer, Theodore [ORNL] (ORCID:0000000174563509)↗

PLASMA HEATING IN A POST ERUPTION CURRENT SHEET: A CASE STUDY BASED ON ULTRAVIOLET, SOFT, AND HARD X-RAY DATA

Off-limb observations of the solar corona after coronal mass ejections (CMEs) often show strong, compact, and persistent UV sources behind the eruption. They are primarily observed by the SOHO/UVCS instrument in the 'hot' [Fe XVIII] λ974 line and are usually interpreted as a signature of plasma heating due to magnetic reconnection in the post-CME current sheet (CS). Nevertheless, the physical process itself and the altitude of the main energy release are currently not fully understood. In this work, we study the evolution of plasma heating after the CME of 2004 July 28 by comparing UV spectra acquired by UVCS with soft and hard X-ray (SXR, HXR) images of the post-flare loops taken by GOES/SXI and RHESSI. The X-ray data show a long-lasting extended source that is rising upward, toward the high-temperature source detected by UVCS. UVCS data show the presence of significant non-thermal broadening in the CS (a signature of turbulent motions) and a strong density gradient across the CS region. The thermal energy released in the HXR source is on the order of ∼10{sup 32} erg, a factor ∼2-5 larger than the energy required to explain the high-temperature plasma sampled by UVCS. Nevertheless, the very different time evolutions of SXR and HXR sources compared with the UV emission suggest that reconnection occurring above the post-eruption arcades is not directly responsible for the high-temperature plasma sampled higher up by UVCS. We conclude that an additional plasma heating mechanism (such as turbulent reconnection) in the CS is likely required.

79 ASTRONOMY AND ASTROPHYSICS↗

Deep learning based event reconstruction for cyclotron radiation emission spectroscopy

The objective of the cyclotron radiation emission spectroscopy (CRES) technology is to build precise particle energy spectra. This is achieved by identifying the start frequencies of charged particle trajectories which, when exposed to an external magnetic field, leave semi-linear profiles (called tracks) in the time–frequency plane. Due to the need for excellent instrumental energy resolution in application, highly efficient and accurate track reconstruction methods are desired. Deep learning convolutional neural networks (CNNs) - particularly suited to deal with information-sparse data and which offer precise foreground localization—may be utilized to extract track properties from measured CRES signals (called events) with relative computational ease. In this work, we develop a novel machine learning based model which operates a CNN and a support vector machine in tandem to perform this reconstruction. A primary application of our method is shown on simulated CRES signals which mimic those of the Project 8 experiment—a novel effort to extract the unknown absolute neutrino mass value from a precise measurement of tritium β - -decay energy spectrum. When compared to a point-clustering based technique used as a baseline, we show a relative gain of 24.1% in event reconstruction efficiency and comparable performance in accuracy of track parameter reconstruction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fluid Mechanics of an Obliquely Mounted MIV Gauge

Over the 40-yr history of shock-compression science, numerous physical phenomena have been considered for use in detecting wave profiles. Few of the devices have actually been used for a significant and persistent study.

47 OTHER INSTRUMENTATION↗

THE EFFECT OF ELECTRON THERMAL PRESSURE ON THE OBSERVED MAGNETIC HELICITY IN THE SOLAR WIND

Statistical analysis of magnetic helicity spectra in the solar wind at 1 au is carried out. A large database of the solar wind intervals assembled from Wind spacecraft magnetic and plasma data is used. The effect of the electron thermal pressure on the wavenumber position of the helicity signature, i.e., the peak of the spectrum, is studied. The position shows a statistically significant dependence on both the electron and proton pressures. However, the strongest dependence is seen when the two pressures are summed. These findings confirm that the generation of the magnetic helicity is associated with an increasing compressibility of the turbulent fluctuations at smaller kinetic scales. It is argued that instrumental artifacts do not contribute to the helicity signature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cosmological Neutron Stars Produce Diffuse Axion X-Ray Signatures

Axion-like particles can be abundantly produced through scattering processes in the cores of neutron stars (NSs). If they are ultralight ($m_a \lesssim 10^{-4}$ eV), then they can efficiently convert to detectable photons in the external NS magnetospheres, and if they are heavy ($m_a \gtrsim 1$ eV), then they can decay into photons before reaching Earth. In this work, we search for the resulting X-ray signatures from both of these channels summing over the $\textit{cosmological}$ NS population. We compare the predicted axion-induced X-ray signal to the cosmic X-ray background today as measured by a number of instruments such as NuSTAR, HEAO, Swift, and INTEGRAL. We model the axion-induced signal using NS cooling simulations and magnetic field evolution models. We find no evidence for axions and derive strong constraints for both ultralight and heavy axion scenarios, covering new parameter space for the axion-photon and axion-nucleon couplings. Our results rule out the axion-explanation of the Magnificent Seven X-ray excess from nearby isolated NSs.

Cosmology and Nongalactic Astrophysics (astro-ph.C↗