Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Overview of Beam Instrumentation and Diagnostics for the NSLS-II Project

A new, ultra-bright 3rd generation light source, the NSLS-II Project, is planned to be built at Brookhaven National Laboratory. The light source being developed will have unprecedently small beam horizontal emittance and will provide the radiation sources with a brightness of 3 x 10{sup 21} photons/sec/0.1%BW/mm{sup 2}/mrad{sup 2}. In this paper we present the detailed specifications and a comprehensive description of the planned beam instrumentation system and the first results of the ongoing instrumentation R&D activities on beyond state-of-the-art subsystems.

43 PARTICLE ACCELERATORS↗

SPECTROSCOPIC OBSERVATIONS OF Fe XVIII IN SOLAR ACTIVE REGIONS

The large uncertainties associated with measuring the amount of high temperature emission in solar active regions (ARs) represents a significant impediment to making progress on the coronal heating problem. Most current observations at temperatures of 3 MK and above are taken with broadband soft X-ray instruments. Such measurements have proven difficult to interpret unambiguously. Here, we present the first spectroscopic observations of the Fe XVIII 974.86 A emission line in an on-disk AR taken with the SUMER instrument on SOHO. Fe XVIII has a peak formation temperature of 7.1 MK and provides important constraints on the amount of impulsive heating in the corona. Detailed evaluation of the spectra and comparison of the SUMER data with soft X-ray images from the X-Ray Telescope on Hinode confirm that this line is unblended. We also compare the spectroscopic data with observations from the Atmospheric Imaging Assembly (AIA) 94 A channel on the Solar Dynamics Observatory. The AIA 94 A channel also contains Fe XVIII, but is blended with emission formed at lower temperatures. We find that it is possible to remove the contaminating blends and form relatively pure Fe XVIII images that are consistent with the spectroscopic observations from SUMER. The observed spectra also contain the Ca XIV 943.63 A line that, although a factor 2-6 weaker than the Fe XVIII 974.86 A line, allows us to probe the plasma around 3.5 MK. The observed ratio between the two lines indicates (isothermal approximation) that most of the plasma in the brighter Fe XVIII AR loops is at temperatures between 3.5 and 4 MK.

79 ASTRONOMY AND ASTROPHYSICS↗

Large amplitude dynamics of micro-/nanomechanical resonators actuated with electrostatic pulses

In the field of resonant nano-electro-mechanical system (NEMS) design, it is a common misconception that large-amplitude motion, and thus large signal-to-noise ratio, can only be achieved at the risk of oscillator instability. In the present paper, we show that very simple closed-loop control schemes can be used to achieve stable large-amplitude motion of a resonant structure even when jump resonance (caused by electrostatic softening or Duffing hardening) is present in its frequency response. We focus on the case of a resonant accelerometer sensing cell, consisting of a nonlinear clamped-clamped beam with electrostatic actuation and detection, maintained in an oscillation state with pulses of electrostatic force that are delivered whenever the detected signal (the position of the beam) crosses zero. We show that the proposed feedback scheme ensures the stability of the motion of the beam much beyond the critical Duffing amplitude and that, if the parameters of the beam are correctly chosen, one can achieve almost full-gap travel range without incurring electrostatic pull-in. These results are illustrated and validated with transient simulations of the nonlinear closed-loop system.

47 OTHER INSTRUMENTATION↗

RECENT X-RAY VARIABILITY OF {eta} CARINAE: THE QUICK ROAD TO RECOVERY

We report continued monitoring of the superluminous binary system {eta} Car by the Proportional Counter Array on the Rossi X-ray Timing Observatory (RXTE) through the 2009 X-ray minimum. The RXTE campaign shows that the minimum began on 2009 January 16, consistent with the phasings of the two previous minima, and overall, the temporal behavior of the X-ray emission was similar to that observed by RXTE in the previous two cycles. However, important differences did occur. The 2-10 keV X-ray flux and X-ray hardness decreased in the 2.5 year interval leading up to the 2009 minimum compared to the previous cycle. Most intriguingly, the 2009 X-ray minimum was about 1 month shorter than either of the previous two minima. During the egress from the 2009 minimum the X-ray hardness increased markedly as it had during egress from the previous two minima, although the maximum X-ray hardness achieved was less than the maximum observed after the two previous recoveries. We suggest that the cycle-to-cycle variations, especially the unexpectedly early recovery from the 2009 X-ray minimum, might have been the result of a decline in {eta} Car's wind momentum flux produced by a drop in {eta} Car's mass loss rate or wind terminal velocity (or some combination), though if so the change in wind momentum flux required to match the X-ray variation is surprisingly large.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IGEC2: A 17-month search for gravitational wave bursts in 2005-2007

We present here the results of a 515 day search for short bursts of gravitational waves by the IGEC2 observatory. This network included 4 cryogenic resonant-bar detectors: AURIGA, EXPLORER, and NAUTILUS in Europe, and ALLEGRO in America. These results cover the time period from November 6th 2005 until April 15th 2007, partly overlapping the first long term observations by the LIGO interferometric detectors. The observatory operated with high duty cycle, namely, 57% for fourfold coincident observations, and 94% for threefold observations. The sensitivity was the best ever obtained by a bar network: we could detect, with an efficiency >50%, impulsive events with a burst strain amplitude h{sub rss} < or approx. 1x10{sup -19} Hz{sup -1/2}. The network data analysis was based on time coincidence searches over at least three detectors, used a blind search technique, and was tuned to achieve a false alarm rate of 1/century. When the blinding was removed, no gravitational wave candidate was found.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Signal processing in the neutral-trigger system of the CMD-3 detector

A method for calorimeter-signal processing intended for deriving input signals for the neutral trigger is considered. An algorithm for digitizing signals is described in detail, along with a simulation of its operation. A brief account of data obtained in tests of a prototype of the signal-processing module that employs the developed algorithm is given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-power microwave LDMOS transistors for wireless data transmission technologies (Review)

The fields of the application, structure, fabrication, and packaging technology of high-power microwave LDMOS transistors and the main advantages of these devices were analyzed. Basic physical parameters and some technology factors were matched for optimum device operation. Solid-state microwave electronics has been actively developed for the last 10-15 years. Simultaneously with improvement of old devices, new devices and structures are actively being adopted and developed and new semiconductor materials are being commercialized. Microwave LDMOS technology is in demand in such fields as avionics, civil and military radars, repeaters, base stations of cellular communication systems, television and broadcasting transmitters, and transceivers for high-speed wireless computer networks (promising Wi-Fi and Wi-Max standards).

36 MATERIALS SCIENCE↗

Improved Devices for Collecting Sweat for Chemical Analysis

Improved devices have been proposed for collecting sweat for biochemical analysis - especially for determination of the concentration of Ca2+ ions in sweat as a measure of loss of Ca from bones. Unlike commercially available sweat-collection patches used previously in monitoring osteoporosis and in qualitative screening for some drugs, the proposed devices would not allow evaporation of the volatile chemical components (mostly water) of sweat. Moreover, the proposed devices would be designed to enable determination of the volumes of collected sweat. From these volumes and the quantities of Ca(2+) and/or other analytes as determined by other means summarized below, one could determine the concentrations of the analytes in sweat. A device according to the proposal would be flexible and would be worn like a commercial sweat-collection patch. It would be made of molded polydimethylsiloxane (silicone rubber) or other suitable material having properties that, for the purpose of analyzing sweat, are similar to those of glass. The die for molding the silicone rubber would be fabricated by a combination of lithography and electroplating. The die would reproducibly form, in the silicone rubber, a precisely defined number of capillary channels per unit area, each channel having a precisely defined volume. Optionally, electrodes for measuring the Ca(2+) content of the sweat could be incorporated into the device. The volume of sweat collected in the capillary channels of the device would be determined from (1) the amount of light or radio waves of a given wavelength absorbed by the device and (2) the known geometry of the array of capillary channels. Then, in one of two options, centrifugation would be performed to move the sweat from the capillary tubes to the region containing the electrodes, which would be used to measure the Ca(2+) content by a standard technique. In the other option, centrifugation would be performed to remove the sweat from the device to make the sweat available to other analytical instruments for measuring concentrations of substances other than Ca(2+).

Feedback, Daniel L.↗

The FIELDS Instrument Suite for Solar Probe Plus Measuring the Coronal Plasma and Magnetic Field, Plasma Waves and Turbulence, and Radio Signatures of Solar Transients

NASA's Solar Probe Plus (SPP) mission will make the first in situ measurements of the solar corona and the birthplace of the solar wind. The FIELDS instrument suite on SPP will make direct measurements of electric and magnetic fields, the properties of in situ plasma waves, electron density and temperature profiles, and interplanetary radio emissions, amongst other things. Here, we describe the scientific objectives targeted by the SPP/FIELDS instrument, the instrument design itself, and the instrument concept of operations and planned data products.

Solar Probe Plus↗

Characterizing and Interpreting the In Situ Strain Tensor During CO 2 Injection

Injecting fluid into a well creates an evolving strain tensor field in the rocks enveloping the well. Understanding the strain field has the potential to improve the effectiveness of CO 2 storage, but the strain tensor had never been measured during injection. The objective of this project was to evaluate how the strain tensor can be measured and interpreted to improve the assessment of geomechanical properties and advance an understanding of geomechanical processes that may present risks to CO 2 storage. The project consisted of three primary tasks related to 1) developing instruments for measuring the strain tensor with high precision; 2) developing methods for analyzing strain signals; and 3) demonstrating the approach at a CO 2 storage analog site.

01 COAL, LIGNITE, AND PEAT↗

Conversions to the Lidar Atmospheric Sensing Experiment (LASE) Instrument for Nadir and Zenith Measurements

LASE now has the advantage of being economically upgraded and customized with COTS hardware and software while using "C" software language. These changes are made so as not to destroy the form, fit and functional characteristics required for flights aboard the ER-2 aircraft. The LASE Instrument can now be quickly adapted to fly onboard ER-2, P-3, C-130 and DC-8 aircraft. The adaptability of the CDS upgraded electronics compliments other modular subsystems like the laser optical bench in that it was designed to be a test bed for new technology lasers.

Moore, Alvah S., Jr.↗

Observations Show Charge Density of Volcanic Plumes is Higher Than Thunderstorms

We analyze slow electric field change and lightning mapping measurements to provide insight into the characteristics of volcanic lightning and the associated implications on charging processes and the charge structure of a Vulcanian eruption plume. Data were obtained during a multi-instrumental field campaign at Sakurajima volcano in 2015 when the Showa crater was active. We combine the electric field change and lightning mapping data from one explosive eruption on June 6, 2015 to identify individual flashes. From this, we interpret the flash type and polarity. In addition, the long-time constant of the electric field change instrument allowed measurement of the quasi-static field associated with charge separation in the eruption plume. We find that both intracloud and cloud-to-ground discharges occurred, and the polarity of cloud-to-ground discharges were all negative. The quasi-static field measurement showed the plume carried a net negative charge. We calculate both the total charge transferred by cloud-to-ground discharges and the net charge density of the eruption plume. We find that cloud-to-ground discharges transfer an average of –0.41C per flash and the net charge density was –33C/ km 3 . Here, the percent error is at least 200%, due to uncertainty in the antenna gain. We show that these estimates are consistent with lightning that is 100 m in length. Further, the average flash rate during the first 8 s following the onset of eruption was five flashes per second. After that time, the flash rate abruptly decreased, which may be related to the end of gas-thrust forcing.

58 GEOSCIENCES↗

Redshifted intergalactic {sup 3}He{sup +} 8.7 GHz hyperfine absorption

Motivated by recent interest in redshifted 21 cm emission of intergalactic hydrogen, we investigate the 8.7 GHz {sup 2}S{sub 1/2} F=0-1 hyperfine transition of {sup 3}He{sup +}. While the primordial abundance of {sup 3}He relative to hydrogen is 10{sup -5}, the hyperfine spontaneous decay rate is 680 times larger. Furthermore, the antenna temperature is much lower at the frequencies relevant for the {sup 3}He{sup +} transition compared to that of z>6 21 cm emission. We find that the spin temperature of this 8.7 GHz line in the intergalactic medium is approximately the cosmic microwave background temperature, such that this transition is best observed in absorption against high-redshift, radio-bright quasars. We show that intergalactic 8.7 GHz absorption is a promising, unsaturated observable of the ionization history of intergalactic helium (for which He II{yields}He III reionization is believed to complete at z{approx}3) and of the primordial {sup 3}He abundance. Instruments must reach {approx}1 {mu}Jy RMS noise in bands of 1 MHz on a 1 Jy source to directly resolve this absorption. However, in combination with H i Ly{alpha} forest measurements, an instrument can statistically detect this absorption from z>3 with 30 {mu}Jy RMS noise in 0.1 MHz spectral bands over 100 MHz, which may be within the reach of present instruments.

79 ASTRONOMY AND ASTROPHYSICS↗

TU-E-TOUR-I-00: Exhibit Hall Guided Tours-Dosimters for QC in Diagnostic Imaging (Tuesday)

Tour Leader: Xia Jiang, Ohio State University, Columbus, OH Tour Guides: Xia Jiang, Ohio State University, Columbus, OH Kevin Little, The University of Chicago, Chicago, IL Christina Sammet, Lurie Children’s Hospital of Chicago, Chicago, IL Participating Vendors: IBA PTW - New York Radcal Corporation RTI Electronics, Inc. Exhibit Hall Guided Tours is a new program launching this year at the Annual Meeting. The Guided Tours are designed to enhance the interaction between meeting attendees and exhibitors. This year’s Imaging Guided Tours are organized around the theme of dosimeters for quality control in diagnostic imaging. Tours will begin with an introduction and background given by Dr. Xia Jiang, the Tour Leader. The introduction will cover the types and properties of different radiation dosimeters used for quality assurance in clinical radiology. Attendees will then break into smaller groups, each lead by an AAPM-member Tour Guide. The tour groups will visit the exhibit booths of vendors who provide appropriate dosimeters, and a vendor representative will give a presentation to the group about their particular product(s). The vendor representatives as well as the Tour Guides will be available to answer questions. Outline: Types and properties of radiation detectors and dosimeters Ionization chamber dosimeters Solid state dosimeters Dosimeter calibration: Primary and secondary standards dosimetry laboratories Instruments for measuring tube voltage and exposure time Vendor presentations will likely cover features and innovations of different dosimeter systems, as well as their practical use. Learning Objectives: Understand the types and properties of different instrumentations used for quality control in diagnostic imaging. Understand the process of dosimeter calibration. Gain familiarity with the latest commercial dosimeter systems from different vendors.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-C-TOUR-I-00: Exhibit Hall Guided Tours-Dosimters for QC in Diagnostic Imaging (Wednesday)

Tour Leader: Xia Jiang, Ohio State University, Columbus, OH Tour Guides: Xia Jiang, Ohio State University, Columbus, OH Kevin Little, The University of Chicago, Chicago, IL Adrien Sanchez, University of Chicago, Chicago, IL Participating Vendors: IBA PTW - New York Radcal Corporation RTI Electronics, Inc. Exhibit Hall Guided Tours is a new program launching this year at the Annual Meeting. The Guided Tours are designed to enhance the interaction between meeting attendees and exhibitors. This year’s Imaging Guided Tours are organized around the theme of dosimeters for quality control in diagnostic imaging. Tours will begin with an introduction and background given by Dr. Xia Jiang, the Tour Leader. The introduction will cover the types and properties of different radiation dosimeters used for quality assurance in clinical radiology. Attendees will then break into smaller groups, each lead by an AAPM-member Tour Guide. The tour groups will visit the exhibit booths of vendors who provide appropriate dosimeters, and a vendor representative will give a presentation to the group about their particular product(s). The vendor representatives as well as the Tour Guides will be available to answer questions. Outline: Types and properties of radiation detectors and dosimeters Ionization chamber dosimeters Solid state dosimeters Dosimeter calibration: Primary and secondary standards dosimetry laboratories Instruments for measuring tube voltage and exposure time Vendor presentations will likely cover features and innovations of different dosimeter systems, as well as their practical use. Learning Objectives: Understand the types and properties of different instrumentations used for quality control in diagnostic imaging. Understand the process of dosimeter calibration. Gain familiarity with the latest commercial dosimeter systems from different vendors.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-C-TOUR-I-01: Dosimters for QC in Diagnostic Imaging

Tour Leader: Xia Jiang, Ohio State University, Columbus, OH Tour Guides: Xia Jiang, Ohio State University, Columbus, OH Kevin Little, The University of Chicago, Chicago, IL Adrien Sanchez, University of Chicago, Chicago, IL Participating Vendors: IBA PTW - New York Radcal Corporation RTI Electronics, Inc. Exhibit Hall Guided Tours is a new program launching this year at the Annual Meeting. The Guided Tours are designed to enhance the interaction between meeting attendees and exhibitors. This year’s Imaging Guided Tours are organized around the theme of dosimeters for quality control in diagnostic imaging. Tours will begin with an introduction and background given by Dr. Xia Jiang, the Tour Leader. The introduction will cover the types and properties of different radiation dosimeters used for quality assurance in clinical radiology. Attendees will then break into smaller groups, each lead by an AAPM-member Tour Guide. The tour groups will visit the exhibit booths of vendors who provide appropriate dosimeters, and a vendor representative will give a presentation to the group about their particular product(s). The vendor representatives as well as the Tour Guides will be available to answer questions. Outline: Types and properties of radiation detectors and dosimeters Ionization chamber dosimeters Solid state dosimeters Dosimeter calibration: Primary and secondary standards dosimetry laboratories Instruments for measuring tube voltage and exposure time Vendor presentations will likely cover features and innovations of different dosimeter systems, as well as their practical use. Learning Objectives: Understand the types and properties of different instrumentations used for quality control in diagnostic imaging. Understand the process of dosimeter calibration. Gain familiarity with the latest commercial dosimeter systems from different vendors.

61 RADIATION PROTECTION AND DOSIMETRY↗

Solar meter with silicon photocell

Instrument for measuring light falling on given spot uses simple silicon photovoltaic cell as sensing element. It measures all light at location: direct, scattered, reflected, or reradiated. Silicon cell is coated with thick antireflecting layer of silicon monoxide and is enclosed in glass dome. Large heat sink reduces temperature fluctuations. Instrument is accurate within few percentage points over angle of Sun's arc across sky.

Yanow, G.↗

Application of in-flight thrust determination uncertainty

A numerical example is given of a previously proposed methodology for the evaluation of in-flight thrust measurement uncertainty, using data extracted from a performance report comparing two different missile prototypes under a variety of flight conditions. Attention is given to the data for the AGM-68B Air Launched Cruise Missile, which is powered by the F107 dual-spool, mixed flow turbofan engine. Assessments are made of the definition of the measurement process, instrumentation error estimation, the propagation of errors to thrust calculation, mathematical model errors, the in-flight thrust error component, and correction to standard conditions. It is concluded that in-flight thrust measurement uncertainty limits can be evaluated from measurement system error analysis results and test data for the missile evaluation process presently described.

Adams, G. R.↗