Search NASA⌕ Search

SEARCH · Search NASA

Results for “Method development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

An Initial Assessment of the Design Margins of Different ASME Section III, Division 5 Design Rules

This report develops a method for assessing the design margin of the ASME Section III, Division 5 Class A design rules, focusing on a definition of margin as the ratio between the actual, expected component life and the ASME design life. Full inelastic finite element simulations with a complete damage model capturing the available creep, creep-fatigue, fatigue, and tension test failure data produce the expected component lives, which can then be compared to corresponding ASME design calculations. The focus of this particular work is on Alloy 617 and the ASME creep-fatigue design rules, but the approach is general and could be applied to other design limits and to other materials. A margin assessment of a representative Alloy 617 component shows the ASME creep-fatigue design rules applied to this component have a margin of 10 on design life. The report describes several challenges in completing a more comprehensive margin assessment of the ASME rules, in particular challenges in developing probabilistic assessment methods for high temperature structural components. The report details these challenge and discusses the immediate possibilities of the deterministic margin assessment method developed here.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Measurements of isocenter path characteristics of the gantry rotation axis with a smartphone application

Purpose: For stereotactic radiosurgery, the AAPM Report No. 54 [AAPM Task Group 42 (AAPM, 1995)] requires the overall stability of the isocenter (couch, gantry, and collimator) to be within a 1 mm radius. In reality, a rotating system has no rigid axis and thus no isocenter point which is fixed in space. As a consequence, the isocenter concept is reviewed here. It is the aim to develop a measurement method following the revised definitions. Methods: The mechanical isocenter is defined here by the point which rotates on the shortest path in the room coordinate system. The path is labeled as “isocenter path.” Its center of gravity is assumed to be the mechanical isocenter. Following this definition, an image-based and radiation-free measurement method was developed. Multiple marker pairs in a plane perpendicular to the assumed gantry rotation axis of a linear accelerator are imaged with a smartphone application from several rotation angles. Each marker pair represents an independent measuring system. The room coordinates of the isocenter path and the mechanical isocenter are calculated based on the marker coordinates. The presented measurement method is by this means strictly focused on the mechanical isocenter. Results: The measurement result is available virtually immediately following completion of measurement. When 12 independent measurement systems are evaluated, the standard deviations of the isocenter path points and mechanical isocenter coordinates are 0.02 and 0.002 mm, respectively. Conclusions: The measurement is highly accurate, time efficient, and simple to adapt. It is therefore suitable for regular checks of the mechanical isocenter characteristics of the gantry and collimator rotation axis. When the isocenter path is reproducible and its extent is in the range of the needed geometrical accuracy, it should be taken into account in the planning process. This is especially true for stereotactic treatments and radiosurgery.

60 APPLIED LIFE SCIENCES↗

Forward problem solution as the operator of filtered and back projection matrix to reconstruct the various method of data collection and the object element model in electrical impedance tomography

Back projection reconstruction has been implemented to get the dynamical image in electrical impedance tomography. However the implementation is still limited in method of adjacent data collection and circular object element model. The study aims to develop the methods of back projection as reconstruction method that has the high speed, accuracy, and flexibility, which can be used for various methods of data collection and model of the object element. The proposed method uses the forward problem solution as the operator of filtered and back projection matrix. This is done through a simulation study on several methods of data collection and various models of the object element. The results indicate that the developed method is capable of producing images, fastly and accurately for reconstruction of the various methods of data collection and models of the object element.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Non-destructive inspection protocol for reinforced concrete barriers and bridge railings

Reinforced concrete highway barriers and bridge railings serve to prevent errant vehicles from departing the travel way at grade separations. Despite the important role that they play in maintaining safety and their ubiquitous nature, barrier inspection rarely moves beyond visual inspection. In August 2008, a tractor-trailer fatally departed William Preston Lane, Jr. Memorial Bridge after it dislodged a section of the bridge barrier. Investigations following the accident identified significant corrosion of the anchor bolts attaching the bridge railing to the bridge deck. As a result of the information gathered during its investigation of the accident, the National Transportation Safety Board (NTSB) made recommendations to the Federal Highway Administration concerning Non-Destructive Evaluation (NDE) of concrete bridge railings. The Center for nondestructive evaluation (NDE) at Turner Fairbank Highway Research Center in McLean, VA is currently evaluating feasibility of using four technologies - ground penetrating radar (GPR), ultrasonic pulse-echo, digital radiography and infrared thermal imaging methods to develop bridge inspection methods that augment visual inspections, offer reliable measurement techniques, and are practical, both in terms of time and cost, for field inspection work. Controlled samples containing predefined corrosion levels in reinforcing steel were embedded at barrier connection points for laboratory testing. All four NDE techniques were used in the initial phase I testing. An inspection protocol for detecting and measuring the corrosion of reinforced steel embedded in the anchorage system will be developed as part of phase II research. The identified technologies shall be further developed for field testing utilizing a structure with a barrier in good condition and a structure with a barrier in poor condition.

42 ENGINEERING↗

Development of Direct Injection/Ionization Mass Spectrometry Methods for Whole Molecule Characterization

The objective of this work is to adapt ambient ionization mass spectrometry (AMS) techniques for the rapid analysis of intact uranium complexes, stable strontium, cerium, and explosive compounds. The methods used were “soft ionization” techniques, which facilitate the detection of whole molecule complexes. The soft ionization mass spectrometry (MS) techniques that were investigated include paper spray ionization (PSI), matrix-assisted ionization (MAI), electrospray ionization (ESI) and direct analysis in real time (DART). For the first time, PSI-MS methods were successfully developed for whole molecule uranium-containing analytes (uranyl acetate, uranyl nitrate, and uranyl-tributylphosphate complexes). This was also the first demonstration of uranium complex detection and characterization and one of the few examples of inorganic analysis using MAI techniques. Proof of concept experiments also putatively identified matrix-derived ions and ion complexes that have not previously been described in the literature. Additionally, PSI-MS on cotton swipe samples doped with a multi-element standard containing μg levels of U, Bi, Pb, Cd, Fe, and Zn were directly analyzed without purification, representing a major improvement over existing methods. Both PSI and MAI methods demonstrated limits of detection (LODs) in the 10 - 100’s ng for various uranyl species within a range of 10’s ppm - 100’s ppb, dependent on analytical method and analyte species. AMS methods were also developed for other inorganics, including Ce and Sr, and organic explosive residues to address specific challenges in environmental monitoring and forensics. Further refinement and qualification of the AMS techniques developed within this effort would lead to significant cost reduction and timeliness by facilitating the triage and queueing of samples for subsequent more sensitive and time-consuming analyses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlations between the Neutron Star Mass–Radius Relation and the Equation of State of Dense Matter

We develop an analytic method of inverting the Tolman–Oppenheimer–Volkoff relations to high accuracy. In principle, a specified energy density–pressure relation gives a unique mass–radius (M–R) relation and vice versa. Our method is developed from the strong correlations that are shown to exist between the neutron star mass–radius curve and the equation of state (EOS) or pressure–energy density relation. Selecting points that have masses equal to fixed fractions of the maximum mass, we find a semi-universal power-law relation between the central energy densities, pressures, sound speeds, chemical potentials, and number densities of those stars, with the maximum mass and the radii of one or more fractional maximum mass points. Rms fitting accuracies, for EOSs without large first-order phase transitions, are typically 0.5% for all quantities at all mass points. The method also works well, although less accurately, in reconstructing the EOS of hybrid stars with first-order phase transitions. These results permit, in effect, an analytic method of inverting an arbitrary M–R curve to yield its underlying EOS. We discuss applications of this inversion technique to the inference of the dense matter EOS from measurements of neutron star masses and radii as a possible alternative to traditional Bayesian approaches.

Bayesian statistics↗

Report on Project performance under the CRADA No PNNL/254, PLA 1, between BATTELLE as operator of Pacific Northwest National Laboratory under its U.S. Department of Energy Contract No. DE-AC05-76RL0 1830 and Isonics Corporation, Chairman and CEO: Christopher M. Toffales

Unattended decontamination of bio agents in enclosed environments. The goal of the project is the development of unattended method for environmentally safe, highly effective volumetric decontamination that kills on a contact multiple bio-agents including airborne and surface-adsorbed pathogens of different nature in enclosed environments with complex geometry like various buildings and transportation units as aircraft and ships The method employs two elements, proprietary Vortical Aerosol Generator (VAG) and Electrochemically Activated Solutions (EAS). The prototype of the method was developed under CRADA No PNNL/254, and was shown highly effective for irreversible decontamination of vegetative microbial cells, spores and viruses in a test chamber of ~100 ft 3 and in a room of ~3000 ft 3 . The electrochemical activation technology is based on the production of meta-stable (activated) solutions with anomalous physicochemical and catalytic reactivity for their further use in various technological processes in place of traditionally applied aggressive chemicals. Usual source for electrochemical activation processes is sodium chloride aqueous solution with the concentration of 1.0 g/L. EAS bactericidal effectiveness was previously demonstrated for different applications however, in all previous applications EAS was only used as a liquid agent. Present Method suggests an application of EAS as micro-aerosol (particle size in the range of 0.5-10 mµ), which behaves like a gas and eventually fills entire enclosed environment including hardly, not otherwise accessible sites. The term micro-aerosol of EAS (MAEAS) herein refers to an air-suspended EAS having micro-particle droplets of characteristic cross section and/or size comprising electrochemically-active agents with sufficiently large surface areas whereby the probability of a contact with bio agents in a process area is extremely high. EAS is produced with a commercially available STEL device (FEM-3 flow electrochemical module element; US Pat 5,635,040). Pneumatic Vortical Aerosol Generator (VAG) produces MAEAS. VAG is an original high output atomizer allowing for the production of the aerosol particles with the size in the range of 0.5 to 12 µm at the rate from 5 to 300 ml/min correspondingly, allowing a control of a required particle size. MAEAS has significant advantages over EAS, allowing for simultaneous decontamination of airborne and surface-adsorbed bio agents with minimal volume of atomized EAS and with essentially no waste. Experimental data indicate that MAEAS has very low corrosiveness, possess no negative effect to sensitive equipment and does not destroy the surface of different tested materials. Limited toxicity tests were conducted with mice directly exposed to EAS aerosol; no acute and short-term toxicity was identified.

bioagents↗

Trace Compound Analysis in TATB by Liquid Chromatography coupled with Spectroscopic and Spectrometric Detection

Accurate quantitation of 1,3,5-triamino-2,4,6-trinitrobenzene (TATB) is important because of its strategic use as an energetic material. A purity determination is also needed for the proper assessment of performance. A fast and sensitive method has been developed to measure the purity of TATB in polymer-bonded materials. The target material is extracted with DMSO, and the extract is separated on a reversed-phase chromatography column. The column effluent is monitored by diode array detection (DAD) at 354 nm. The characteristic UV-Vis response and retention time identify the individual components when compared to pure compound standards. The chemical structures of compounds with no pure standards available have been determined by high-resolution mass spectrometry (MS) and MS/MS. The major component, TATB, along with 1-chloro-3,5-dinitro-2,4,6-triaminobenzene (T4A) and mono-benzofuroxan (FX1) were quantitated directly from pure compound standards. Several trace concentration components, mono-benzofurazan (F1), 1-bromo-3,5-dinitro-2,4,6-triaminobenzene (Br-T4A), 2,4,6-triamino-1-nitroso-3,5-dinitrobenzene (MN-TATB), 2,4,6-triamino-1-hydroxyl-3,5-dinitrobenzene (HO-TATB), and 2,4,6-triamino-1-nitrile-3,5-dinitrobenzene (Nitrile-TATB) were also detected and structures verified via MS/MS. Approximate concentrations were determined using calibrations from standards of similar structures. Additional trace components were also detected by MS. Contained herein are the results of analyses of TATB-based materials characterized for polymer-bonded formulations compared to different preparations of TATB. The accuracy, details, and process of developing this method are reported here.

36 MATERIALS SCIENCE↗

Uncovering the Size-dependent Thermal Solid Transformation of Akaganéite

Investigating the structural evolution and phase transformation of iron oxides is crucial for gaining a deeper understanding of geological changes on diverse planets and preparing oxide materials suitable for industrial applications. In this study, we employed in-situ heating techniques in conjunction with transmission electron microscopy (TEM) observations and ex-situ characterization to thoroughly analyze the thermal solid-phase transformation of akaganéite one-dimensional (1D) nanostructures with varying diameters. Our findings offer compelling evidence for a size-dependent morphology evolution in akaganéite 1D nanostructures, which can be attributed to the transformation from akaganéite to maghemite (?-Fe2O3) and subsequent crystal growth. Specifically, we observed that akaganéite nanorods with a diameter of around 50 nm transformed into hollow polycrystalline maghemite nanorods, which demonstrated remarkable stability without arresting crystal growth under continuous heating. In contrast, smaller akaganéite nanoneedles or nanowires with a diameter ranging from 20 to 8 nm displayed a propensity for forming single-crystal nanoneedles or nanowires through phase transformation and densification. By manipulating the size of the precursors, we have developed a straightforward method for the synthesis of single-crystal and polycrystalline maghemite nanowires through solid-phase transformation. These significant findings provide new insights into the size-dependent structural evolution and phase transformation of iron oxides at the nanoscale.

Wang, Xiang↗

Development of a method for high LET irradiation of liquid systems

A variety of processes, from material sterilization and cancer treatment to used nuclear fuel recycling, benefit from quantifying the sensitivity of the system to radiation. Determining the effects of alpha irradiation on a system may be of complementary interest to the effects of gamma irradiation, as alpha radiation has higher linear energy transfer (LET) and will likely result in different chemical damage effects. This becomes important in advanced nuclear fuel cycle processes where the radioactive materials to be handled in solutions contain significant amounts of alpha emitters. In this work, we describe a method for studying high LET radiation in a liquid system using a TRIGA® reactor and the 10 B(n,α) 7 Li reaction. By fitting a model based on neutron diffusion and absorption to experimentally obtained Fricke dosimetry data, the high LET dose to a sample was predictable over the full range of reactor power available and varying 10 B concentration. This method may be applied to study the effects of high LET radiation on any liquid system as long as a suitable molecule containing boron is used and appropriate neutron diffusion coefficients are known. A wide range of high LET dose rates from <10 Gy/h to >1,000 kGy/h may be obtained with this method.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of optimal methods for collection, transportation, holding, handling, and tagging of juvenile American shad

American shad (Alosa sapidissima) are an anadromous fish species native to the United States that have an extensive range along the east coast, but their populations are declining worldwide. Acoustic telemetry can play a vital role in better understanding the behavior and survival of this sensitive species. A stepwise, systematic approach was used to assess juvenile shad survival during multiple stressors typically associated with an acoustic telemetry study. Minimizing out-of-water handling and the use of saltwater during collection increased 24-hour survival (78 to 99%) between the first two shad transports. Several experiments were conducted to determine the best transmitter design method for implanting juvenile shad. Saltwater was fundamental in keeping tagged shad alive overnight and during the tagging process. Shad as small as 50 mm were tagged using the pectoral incision method with no suture. In a 60-d holding evaluation, tagged fish survived at a comparable rate as their non-tagged counterparts (81.5% for tagged, 70% for untagged). Also, when tagged and untagged shad were exposed to a tank of predators, there was no difference in their survival. Results from this study are encouraging for improving conservation efforts for small, sensitive species of fish, like American shad. The techniques identified may help broaden the application of telemetry studies by informing researchers of optimal methods to ensure survival of tagged fish in future field studies looking to evaluate survival and entrainment rates of juvenile American shad.

59 BASIC BIOLOGICAL SCIENCES↗

Novel epoxy-silica nanoparticles to develop non-enzymatic colorimetric probe for analytical immuno/bioassays

We have developed a novel method to develop epoxy silica nanoparticles (EfSiNP) in a single pot. High surface coverage of epoxy functional groups between 150 and 57000 molecules per particles (~10 13 –10 16 molecules/mL of 200 nm EfSiNPs) was achieved for different preparation conditions. We then created a red colored probe by conjugating Fuchsin dye to the epoxy functionalities of EfSINPs. Anti-mouse IgG was co-immobilized with Fuchsin and their ratios were optimized for achieving optimum ratios by testing those in functional assays. Dye to antibody ratios were in good negative correlation with a coefficient of -1.00 measured at a confidence level of over 99%. We employed the developed non-enzymatic colorimetric immunonanoprobe for detecting mouse IgG in a direct immunoassay format. We achieved a sensitivity of 427 pg/mL with the assay.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Inhibition of Notch signaling pathway using γ-secretase inhibitor delivered by a low dose of Triton-X100 in cultured oral cancer cells

Highlights: • A novel method is developed to deliver γ-secretase inhibitor DAPT using a low dose of Triton-X100. • This approach effectively blocks the cleavage of Notch1 receptor. • The elimination of Notch1 intracellular domain from cell nuclei is confirmed. • Notch1 signaling blockade in mRNA level is demonstrated upon applying this delivery system. How to effectively delivering therapeutic agents, including γ-secretase inhibitors (GSIs), into live cells, remains a significant challenge. This study assessed the effect of Notch signaling inhibition by examining levels of the Notch1 intracellular domain (N1ICD) in cultured oral cancer cells analyzed with random stitched images (2D) and 3D visualizations using confocal microscopy and quantitative gene analysis. Substantially, we have developed a novel method to assist the delivery of γ-secretase inhibitor, DAPT, into live cells in the presence of an effective minimum concentration of Triton-X100 (0.001%) without damaging cell activity and membrane integrity assessed with cell proliferation assays. The images obtained in this study showed that DAPT alone could not block the γ-secretase inhibitor despite inhibiting cell growth. Further analysis of quantitative gene expressions of Notch signaling canonical pathway to verify the effectiveness of the novel method for delivering inhibitor into live cells, displayed deregulation of Notch1, Delta-like ligand 1 (DLL1) and hairy and enhancer of split 1 (Hes1). Our data suggest that Notch1/Hes1 signaling pathway is deactivated using DAPT with a low dose of Triton-X100 in this cancer cells. And the finding also suggests that Notch1 could be engaged by DLL1 to promote differentiation in oral cancer cells. Using this approach, we demonstrate that Triton-X100 is a promising and effective permeabilization agent to deliver γ-secretase inhibitor DAPT into live oral epithelial cells. This strategy has the potential to implicate in the treatment of cancer diseases.

60 APPLIED LIFE SCIENCES↗

Toward Magnetic Resonance–Only Simulation: Segmentation of Bone in MR for Radiation Therapy Verification of the Head

Purpose: To develop a practical method to localize bones in magnetic resonance (MR) images, to create “computed tomography–like” MR images (ctMRI) that could be used for radiation therapy verification, and to generate MR-based digitally reconstructed radiographs (DRR). Methods and Materials: Using T1-weighted MR images, an air mask was derived from the manual contouring of all airways within the head and neck region using axial images at 6 anatomic levels. Compact bone, spongy bone, and soft tissue masks were then automatically generated using the statistical data derived from MR intensities and the air mask. ctMRI were then generated by mapping the MR intensities of the voxels within these masks into the CT number ranges of corresponding tissues. MR-based DRRs created from ctMRI were quantitatively evaluated using the co-registered MR and CT head images of 20 stereotactic radiosurgery patients. Ten anatomical points, positioned on the skull segmented using a threshold of 300 HU, in CT and ctMRI, were used to determine the differences in distance between MR-based DRRs and CT-based DRRs, and to evaluate the geometric accuracy of ctMRI and MR-based DRRs. Results: The bony structures were identified on ctMRI and were visible in the MR-based DRRs. From the 20 patient cases, the mean geometric difference and standard deviation between the 10 anatomical points on MR-based and CT-based DRRs was −0.05 ± 0.85 mm, respectively. This included uncertainty in image fusion. The maximum distance difference was 1.88 mm. Conclusions: A practical method was developed to segment bone from MR images. The ctMRI created can be used for radiation treatment verification when MR-only simulation is performed. MR-based DRRs can be used in place of CT-based DRRs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A new microphonics measurement method for superconducting RF cavities

Mechanical vibrations of the superconducting cavity, also known as microphonics, cause shifts in the resonant frequency of the cavity. In addition to requiring additional RF power, these frequency shifts can contribute to errors in the closed loop phase and amplitude regulation. In order to better understand these effects, a new microphonics measurement method was developed, and the method was successfully used to measure microphonics on the half-wave superconducting cavity when it was operated in a production style cryostat. The test cryostat held a single β=0.1 half-wave cavity which was operated at 162.5 MHz [1] and [2]. It's the first time that the National Instruments PXIe-5641R intermediate frequency transceiver has been used for microphonics measurements in superconducting cavities. The new microphonics measurement method and results will be shown and analyzed in this paper.

Gao, Zheng↗

Interior Decoration of Stable Metal–Organic Frameworks

Metal–organic frameworks (MOFs) are a diverse class of hybrid organic/inorganic crystalline materials composed of metal-containing nodes held in place by organic linkers. Through a discerning selection of these components, many properties such as the internal surface area, cavity size and shape, catalytic properties, thermal properties, and mechanical properties may be manipulated. Because of this high level of tunability, MOFs have been heralded as ideal platforms for various applications including gas storage, separation, catalysis, and chemical sensing.(1-8) Regrettably, these theoretical possibilities are limited by the reality of constraining conditions for solvothermal synthesis, which typically include high temperatures (usually over 100 °C), the use of specific solvents, and necessary exposure to acidic or basic conditions. In order to incorporate more delicate functionalities, postsynthesis decoration methods were developed. This feature article focuses on developed interior decoration methods for stable MOFs and the dynamic relationship between such methods and MOF stability. In particular, methods to transform organic, inorganic, and organometallic MOF parts as well as combination techniques, the generation of defects, and the inclusion of enzymes are addressed.

36 MATERIALS SCIENCE↗

Investigation of plasma immersion ion implantation of nickel-titanium rod by multiple-grid particle-in-cell simulation

A multiple-grid-particle-in-cell numerical method has been developed. This method uses grids of different cell sizes and details are needed in only one part of the simulation region and not others. Hence, there are fewer nodes in the simulation thereby reduced computational time without sacrificing details. In the multiple-grid system, a phenomenon is identified to arise at the interface between two grids and a half-cell weighting method is utilized to solve the weighting issue at the boundary. It is shown that the expression of the change of momentum has no weighting function. This method is employed to numerically simulate the plasma immersion ion implantation process into a nickel titanium rod measuring 50 mm long and 4.8 mm in diameter used in orthopaedic surgery. To conduct more uniform implantation, the NiTi rod is elevated on the sample stage by a metal rod. The nitrogen implantation fluences and depth profiles are simulated and compared to experimental values determined by x-ray photoelectron spectroscopy.

36 MATERIALS SCIENCE↗