Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microscope and microscopy.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Single Molecule and Nanoparticle Imaging in Biophysical, Surface, and Photocatalysis Studies

A differential interference contrast (DIC) polarization anisotropy is reported that was successfully used for rotational tracking of gold nanorods attached onto a kinesin-driven microtubule. A dual-wavelength detection of single gold nanorods rotating on a live cell membrane is described. Both transverse and longitudinal surface plasmon resonance (SPR) modes were used for tracking the rotational motions during a fast dynamic process under a DIC microscope. A novel method is presented to determine the full three-dimensional (3D) orientation of single plasmonic gold nanorods rotating on live cell membranes by combining DIC polarization anisotropy with an image pattern recognition technique. Polarization- and wavelength-sensitive DIC microscopy imaging of 2- m long gold nanowires as optical probes in biological studies is reported. A new method is demonstrated to track 3D orientation of single gold nanorods supported on a gold film without angular degeneracy. The idea is to use the interaction (or coupling) of gold nanorods with gold film, yielding characteristic scattering patterns such as a doughnut shape. Imaging of photocatalytic activity, polarity and selectivity on single Au-CdS hybrid nanocatalysts using a high-resolution superlocalization fluorescence imaging technique is described.

36 MATERIALS SCIENCE↗

Scanning Electron Microscope Mapping System Developed for Detecting Surface Defects in Fatigue Specimens

An automated two-degree-of-freedom specimen positioning stage has been developed at the NASA Glenn Research Center to map and monitor defects in fatigue specimens. This system expedites the examination of the entire gauge section of fatigue specimens so that defects can be found using scanning electron microscopy (SEM). Translation and rotation stages are driven by microprocessor-based controllers that are, in turn, interfaced to a computer running custom-designed software. This system is currently being used to find and record the location of ceramic inclusions in powder metallurgy materials. The mapped inclusions are periodically examined during interrupted fatigue experiments. The number of cycles to initiate cracks from these inclusions and the rate of growth of initiated cracks can then be quantified. This information is necessary to quantify the effect of this type of defect on the durability of powder metallurgy materials. This system was developed with support of the Ultra Safe program.

Bonacuse, Peter J.↗

Further Characterization of Aerosols Sampled on the International Space Station

Spacecraft cabin air quality is of fundamental importance to crew health, with concerns encompassing both gaseous contaminants and airborne particles. Quantification of spacecraft indoor aerosols will increase our understanding of crew exposure and cabin cleanliness. Aerosols on the International Space Station (ISS) have been sampled and brought back to Earth for analysis to characterize the airborne particulate matter in the cabin. Microscopic analyses have been performed to determine morphology and particle size information, and Energy Dispersive X-ray Spectroscopy (EDS) provides information on the chemical elements present in the particles. With the use of IntelliSEM software for computer-controlled scanning electron microscopy (CCSEM), this data provides particle size distribution information and statistics on particle materials. Many of the particles collected were made up of multiple elements and had uncommon morphologies compared to typical indoor aerosols on Earth. These characteristics are thought to be from unique formation mechanisms in the microgravity environment. Several notable particle types are examined further in this work. Bromine-containing particles and cadmium-containing particles are discussed as they constitute a health hazard to crew members. Humans in indoor living and working spaces are typically the single largest particle emission source, and this was observed in the sampled aerosols in ISS as well.

Sampling↗

Electron Microscopy of Microbial Biomass

As humans move to long term stays in space their microbes move with them. This poses problems as the microbes can colonize various life support systems, creating biofilms that can grow and spread, which in turn causes obstructions and ultimately degrades function of these systems. MSFC currently has no protocol in place for the Scanning Electron Microscope (SEM) imaging of microbes.

Samantha Marcella↗

Electrical characterization of HgTe nanowires using conductive atomic force microscopy

Self-organized HgTe nanowires grown by molecular beam epitaxy (MBE) have been characterized using conductive atomic force microscopy. As HgTe will degrade or evaporate at normal baking temperatures for electron beam lithography (EBL) resists, an alternative method was developed. Using low temperature optical lithography processes, large Au contacts were deposited on a sample covered with randomly oriented, lateral HgTe nanowires. Nanowires partly covered by the large electrodes were identified with a scanning electron microscope and then localized in the atomic force microscope (AFM). The conductive tip of the AFM was then used as a movable electrode to measure current-voltage curves at several locations on HgTe nanowires. The measurements revealed that polycrystalline nanowires had diffusive electron transport, with resistivities two orders of magnitude larger than that of an MBE-grown HgTe film. The difference can be explained by scattering at the rough surface walls and at the grain boundaries in the wires. The method can be a solution when EBL is not available or requires too high temperature, or when measurements at several positions along a wire are required.

36 MATERIALS SCIENCE↗

Study of the time effect on the strength of cell-cell adhesion force by a novel nano-picker

Highlights: {yields} A nano-picker is developed for single cell adhesion force measurement. {yields} The adhesion of picker-cell has no influence to the cell-cell measurement result. {yields} Cell-cell adhesion force has a rise at the first few minutes and then becomes constant. -- Abstract: Cell's adhesion is important to cell's interaction and activates. In this paper, a novel method for cell-cell adhesion force measurement was proposed by using a nano-picker. The effect of the contact time on the cell-cell adhesion force was studied. The nano-picker was fabricated from an atomic force microscopy (AFM) cantilever by nano fabrication technique. The cell-cell adhesion force was measured based on the deflection of the nano-picker beam. The result suggests that the adhesion force between cells increased with the increasing of contact time at the first few minutes. After that, the force became constant. This measurement methodology was based on the nanorobotic manipulation system inside an environmental scanning electron microscope. It can realize both the observation and manipulation of a single cell at nanoscale. The quantitative and precise cell-cell adhesion force result can be obtained by this method. It would help us to understand the single cell interaction with time and would benefit the research in medical and biological fields potentially.

60 APPLIED LIFE SCIENCES↗

Nanoscale Polarization-Dependent Young’s Modulus of Ferroelectric BaTiO 3 Single Crystals

Flexoelectric fields produced by strong strain gradients at the nanoscale couple to ferroelectric polarization, promoting changes in the mechanical properties of ferroelectric materials as a function of the direction of the ferroelectric polarization. In this work, we calculate the asymmetry in the Young’s modulus found in oppositely polarized out-of-plane domains of BaTiO 3 single crystals by means of contact resonance AFM, and we evaluate its impact on the electromechanical response as measured by piezoresponse force microscopy, both using band excitation modes. Furthermore, we analyze the electromechanical response of the different BaTiO 3 domains using k-means to build up their mean elastic and electromechanical features and quantify the flexoelectrically induced modulation of the Young’s modulus. Finally, we discuss the use of contact Kelvin probe force microscope measurements to decouple electrostatic artifacts from purely piezoelectric ones when flexoelectric coupling appears.

BaTiO 3 single crystals↗

Helium bubble evolution in a Zr–Sn–Nb–Fe–Cr alloy during post-annealing: An in-situ investigation

The formation of helium bubbles is considered to be detrimental to the mechanical performance of the nuclear materials. The growth behaviors of helium bubbles in a helium ion implanted Zr–Sn–Nb–Fe–Cr alloy with respect to the helium fluence and subsequently annealing procedure were investigated by in-situ transmission electron microscopy. In the as-implanted sample, the measured size distributions of the helium bubbles are consistent with the simulated helium concentrations. Moreover, the mean size of the helium bubbles increases with the increase of the irradiation temperatures and the helium fluence. The in-situ heating study performed in a transmission electron microscope indicates that the mean size of the helium bubbles increase slowly below 923 K and dramatically above 923 K. The coarsening mechanism of the helium bubbles in the alloy is suggested based on the study. - Highlights: • Helium bubble growth in zirconium with annealing was in-situ investigated in TEM. • The mean helium bubble size increase with helium fluence and annealing temperature. • Helium bubble size distribution is same as that of helium concentration by SRIM. • Mean bubble size increases slowly and quickly with temperature below and above 923 K. • The growth mechanism of the helium bubbles in Zr alloy has been discussed.

36 MATERIALS SCIENCE↗

Two-Dimensional Molecular Charge Density Waves in Single-Layer-Thick Islands of a Dirac Fermion System

Charge density waves have been intensely studied in inorganic materials such as transition metal dichalcogenides however its counterpart in organic materials has yet to be explored in detail. Here we report the finding of a robust two dimensional charge density waves in molecular layers formed by α-(BEDT-TTF) 2 -I 3 on a Ag(111) surface. Low temperature scanning tunnelling microscopy images of a multi-layer thick α-(BEDT-TTF) 2 -I 3 on Ag(111) substrate reveal coexistence of 5a0 x 5a0 and √31 a0 x √31 a0 R9° charge density wave patterns commensurate with the underlying molecular lattice at 80 K. Both charge density wave patterns remain in nano-size molecular islands with just a single constituent molecular-layer thickness at 80 K and 5 K. Local tunneling spectroscopy measurements reveal the variation of the gap from 244 meV to 288 meV between the maximum and minimum charge density wave locations. Density functional theory calculations further confirm a vertical positioning of BEDT-TTF molecules in the molecular layer. While the observed charge density wave patterns are stable for the defect sites, they can be reversely switched for one molecular lattice site by means of inelastic tunnelling electron energy transfer with the electron energies exceeding 400 meV using a scanning tunneling microscope manipulation scheme.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of transverse electron pulse trains using RF powered traveling wave metallic comb striplines

Advancements in ultrafast electron microscopy have allowed elucidation of spatially selective structural dynamics. However, as the spatial resolution and imaging capabilities have made progress, quantitative characterization of the electron pulse trains has not been reported at the same rate. In fact, inexperienced users have difficulty replicating the technique because only a few dedicated microscopes have been characterized thoroughly. Systems replacing laser driven photoexcitation with electrically driven deflectors especially suffer from a lack of quantified characterization because of the limited quantity. The primary advantages to electrically driven systems are broader frequency ranges, ease of use and simple synchronization to electrical pumping. Here, we characterize the technical parameters for electrically driven UEM including the shape, size and duration of the electron pulses using low and high frequency chopping methods. At high frequencies, pulses are generated by sweeping the electron beam across a chopping aperture. For low frequencies, the beam is continuously forced off the optic axis by a DC potential, then momentarily aligned by a countering pulse. Using both methods, we present examples that measure probe durations of 2 ns and 10 ps for the low and high frequency techniques, respectively. Here, we also discuss how the implementation of a pulsed probe affects STEM imaging conditions by adjusting the first condenser lens.

36 MATERIALS SCIENCE↗

SU-F-T-665: Confocal Microscopy Imaging of Cell Cycle Distribution in Cells Treated with Pegylated Gold Nanoshells

Purpose: To use confocal microscopy to distinguish cells in different phases of the cell cycle before and after treatment with pegylated gold nanoshells (PEG-AuNSs). Methods: Transfected fibrosarcoma cells (HT1080-EYFP-53BP1-FUCCI) were cultured in T-25 flasks and seeded in glass bottom dishes. These cells express the fluorescent probe AmCyan during the G2/S phases of the cell cycle, mCherry during the G1 phase, and EYFP tagged to the DNA repair protein 53BP1. After allowing cells 4 h to adhere to dishes, PEG-AuNS (Nanospectra Biosciences, Houston, TX) at a concentration of 0.15 OD were administered. At time points of 8, 16 and 24 h following treatment, the PEG-AuNS-treated and control samples were washed with phosphate buffered saline (PBS) and fixed using 4% paraformaldehyde in PBS. Samples were imaged with an Olympus FV1200 confocal microscope using 473, 543, and 641 nm excitation lasers. We used band-pass filters to select AmCyan and mCherry fluorescence. Reflection from the 641 nm laser was used to detect PEG-AuNSs. Z-stack images were analyzed to assess cell cycle distribution through fluorescent probe expression. Live cells were imaged after PEG-AuNS treatment using a confocal microscope with a stage top CO2 incubator. Results: We were able to obtain high-resolution images of cells with internalized AuNSs. We were also able to distinguish cells in different phases of the cell cycle. Conclusion: This work demonstrates a new assay to investigate the effect of AuNSs on the cell cycle phase in live cells. Future work will employ confocal microscopy and flow cytometry to focus on effects of AuNS treatment on cell cycle distribution. This research was supported by the Sister Institution Network Fund and the Center for Radiation Oncology Research at The University of Texas MD Anderson Cancer Center and Cancer Prevention and Research Institute of Texas. Gabriel Sawakuchi has research support from Elekta Inc.

60 APPLIED LIFE SCIENCES↗

Cryo-electron Microscopy of Adeno-associated Virus

Adeno-associated virus (AAV) has a single-stranded DNA genome encapsidated in a small icosahedrally symmetric protein shell with 60 subunits. AAV is the leading delivery vector in emerging gene therapy treatments for inherited disorders, so its structure and molecular interactions with human hosts are of intense interest. A wide array of electron microscopic approaches have been used to visualize the virus and its complexes, depending on the scientific question, technology available, and amenability of the sample. Approaches range from subvolume tomographic analyses of complexes with large and flexible host proteins to detailed analysis of atomic interactions within the virus and with small ligands at resolutions as high as 1.6 Å. Analyses have led to the reclassification of glycan receptors as attachment factors, to structures with a new-found receptor protein, to identification of the epitopes of antibodies, and a new understanding of possible neutralization mechanisms. AAV is now well-enough characterized that it has also become a model system for EM methods development. Heralding a new era, cryo-EM is now also being deployed as an analytic tool in the process development and production quality control of high value pharmaceutical biologics, namely AAV vectors.

59 BASIC BIOLOGICAL SCIENCES↗

In situ atomic force microscope study of high-temperature untwinning surface relief in Mn-Fe-Cu antiferromagnetic shape memory alloy

The N-type untwinning surface relief associated with the fcc {r_reversible} fct martensitic transformation (MT) was observed in the Mn{sub 81.5}Fe{sub 14.0}Cu{sub 4.5} antiferromagnetic high-temperature shape memory alloy (SMA) by in situ atomic force microscopy. The measured untwinning relief angles ({theta}{sub {alpha}} Double-Vertical-Line {theta}{sub {beta}}) at the ridge and at the valley were different, and both angles were less than the conventional values. The surface relief exhibited good reversibility during heating and cooling because of the crystallographic reversibility of thermal-elastic SMAs. Untwinning shear was proposed as the main mechanism of the N-type surface relief. The order of the reverse MT was discussed based on the experimental measurements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Bridging multimodal microscopy for advanced characterization on nuclear fuel using machine learning

Uranium dioxide (UO 2 ), widely used as driver fuel in light water reactors, experiences microstructure and property change by nuclear fission reactions. This paper bridges the characterization of fresh UO 2 fuel at different length scales, serving as a baseline for future post irradiation examination of irradiated UO 2 fuel. To characterize the microstructural change of nuclear fuel, modern approaches cover a wide range of length scales through different characterization techniques, such as mm scale for Synchrotron-based X-ray computed tomography (SXCT) and microscale for focused ion beam (FIB) and scanning electron microscopy (SEM). It is challenging to bridge the data and knowledge of the same sample in different length scales. This paper proposed a deep learning framework leveraging transfer learning to detect microstructural defects, trained from a sparse FIB, SEM, and SXCT images. The proposed model achieved superior performance in defect segmentation on multiscale microscopic data compared to four of the latest deep learning models.

36 MATERIALS SCIENCE↗

Nanochannel-Directed Growth of One-Dimensional Multi-Segment Heterojunctions of Metallic Au1-xGex and Semiconducting Ge

We report on the synthesis of multi-segment nanowire (NW) junctions of Au{sub 1-x}Ge{sub x} and Ge inside the nanochannels of porous anodic aluminum oxide template. The one-dimensional heterostructures are grown with a low-temperature chemical vapor deposition process, assisted by electrodeposited Au nanowires (AuNWs). The Au-catalyzed vapor-liquid-solid growth process occurs simultaneously in multiple locations along the nanochannel, which leads to multi-segment Au{sub 1-x}Ge{sub x}/Ge heterojunctions. The structures of the as-grown hybrid NWs, analyzed by using transmission electron microscopy and energy-dispersive X-ray spectroscopy elemental mapping, show clear compositional modulation with variable modulation period and controllable junction numbers. Remarkably, both GeNW and Au{sub 1-x}Ge{sub x}NW segments are single crystalline with abrupt interfaces and good crystallographic coherences. The electronic and transport properties of individual NW junctions are measured by using a multi-probe scanning tunneling microscope, which confirms the semiconducting nature of Ge segments and the metallic behavior of Au{sub 1-x}Ge{sub x} segments, respectively. The high yield of multiple segment NW junctions of a metal-semiconductor can facilitate the applications in nanoelectronics and optoelectronics that harness multiple functionalities of heterointerfaces.

36 MATERIALS SCIENCE↗

Autogenous healing of Engineered Cementitious Composites (ECC) based on MgO-fly ash binary system activated by carbonation curing

Developing self-healing of concrete cracks represents a critical approach for extending material longevity. If demonstrated on concretes with CO 2 stored through carbonation curing, self-healing can further mitigate infrastructure lifecycle emissions. In this study, the self-healing process is investigated on novel Engineered Cementitious Composites (ECC) based on binary blends of reactive MgO cement and siliceous fly ash activated by carbonation. The self-healing was observed under cyclic wetting and drying exposures and was characterized by measurements of resonance frequency, optical microscopy and X-ray computed microtomography (XCT). Thermogravimetric analysis, X-ray powder diffraction and scanning electron microscopy were employed to assist in identifying healing products and mechanisms. It was found that micro-cracks could be autogenously filled in 7 wet-dry cycles, as evidenced by over 95% recovery of resonance frequency and healed crack appearance under optical microscopic observation. Nevertheless, the composite mechanical performance, particularly tensile strength and ductility, did not fully recover with respect to the uncracked specimens. The inadequate post-healing mechanical properties were consistent with XCT observations that indicated low material densities in the cracked area. Based on the chemical and microstructural characterizations, it was determined that nesquehonite crystallites were responsible for the crack filling. Although the nesquehonite filled cracks will be less permeable to invasion of reactive fluids, novel strategies are needed to establish more robust healing capability to completely restore the crack bridging and composite tensile performance.

36 MATERIALS SCIENCE↗

Extracting physically interpretable data from electron energy-loss spectra.

Principal component analysis is routinely applied to analyze data sets in electron energy-loss spectroscopy (EELS). We show how physically meaningful spectra can be obtained from the principal components using a knowledge of the scattering of the probe electron and the geometry of the experiment. This approach is illustrated by application to EELS data for the carbon K edge in graphite obtained using a conventional transmission electron microscope. The effect of scattering of the probe electron is accounted for, yielding spectra which are equivalent to experiments using linearly polarized X-rays. The approach is general and can also be applied to EELS in the context of scanning transmission electron microscopy.

36 MATERIALS SCIENCE↗