Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mix Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Exploring nonsupersymmetric new physics in polarized Moeller scattering

We study in an effective operator approach how the effects of new physics from various scenarios that contain an extra Z{sup '} neutral gauge boson or doubly charged scalars, can affect and thus be tested by the precision polarized Moeller scattering experiments. We give Wilson coefficients for various classes of generic models, and we deduce constraints on the parameter space of the relevant coupling constants or mixing angles from the results of the SLAC E158 experiment where applicable. We give also constraints projected from the upcoming 1 ppb JLAB experiment. In the scenario where the extra Z{sup '} is light (M{sub Z{sup '}}<<M{sub W}), we obtain further constraints on the parameter space using the BNL g-2 result where it is useful. We find that the BNL deviation from the standard model cannot be attributed to a light extra Z{sup '} neutral gauge boson.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effect of APS flash bond coatings on furnace cycle lifetime of disks and rods

Air plasma sprayed (APS) flash coatings on high velocity oxygen fuel (HVOF) bond coatings are well known to extend the lifetime of thermal barrier coatings. Recent work compared flash coatings of NiCoCrAlY and NiCoCrAlYHfSi applied to both rods and disk substrates of alloy 247. For rod specimens, 100-h cycles were used at 1100°C in wet air. Both flash coatings significantly improved the lifetime compared to HVOF-only and VPS-only MCrAlY bond coatings with no statistical difference between the two flash coatings. For disk specimens tested in 1-h cycles at 1100°C in wet air, the NiCoCrAlY flash coating significantly outperformed an HVOFonly NiCoCrAlYHfSi bond coating and a NiCoCrAlYHfSi flash coating. The flash coatings formed a mixed oxide-metal zone that appeared to inhibit crack formation and extend lifetime. In addition to the flash coating increasing the bond coating roughness, the underlying HVOF layer acted as a source of Al for this intermixed zone and prevented the oxide from penetrating deeper into the bond coating. The lower Y+Hf level in the Y-only flash coating appeared to minimize oxidation in the flash layer, thereby increasing the benefit compared to a NiCoCrAlYHfSi flash coating.

Pint, Bruce↗

Investigating the Particle Growth in Bimodal Pt/C Catalysts by In-Situ Small-Angle X-ray Scattering: Challenges in the Evaluation of Stress Test Protocol-Dependent Degradation Mechanisms

The influence of different combinations of accelerated stress test (AST) protocols simulating load-cycle and start/stop conditions of a proton exchange membrane fuel cell (PEMFC) vehicle is investigated on a bimodal Pt/C catalyst. The bimodal Pt/C catalyst, prepared by mixing two commercial catalysts, serves as a model system and consists of two distinguishable size populations. The change in mean particle size was investigated by in situ small-angle X-ray scattering (SAXS). The comparison to the reference catalysts, i.e., the two single-size population catalysts, uncovers the presence of electrochemical Ostwald ripening as a degradation mechanism in the bimodal catalyst. Increasing the harshness of the applied AST protocol combinations by faster changing between load-cycle or start/stop conditions, the particle size of the larger population of the bimodal catalyst increases faster than expected. Surprisingly, the change in mean particle size of the smaller size population indicates a smaller increase for harsher AST protocols, which might be explained by a substantial electrochemical Ostwald ripening.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In situ characterization of two unknown ultrashort laser pulses using four-wave mixing in gas

Accurate characterization of two ultrashort laser pulses is of great interest in many ultrafast pump-probe experiments. We demonstrate a method based on four-wave mixing (FWM) in a gas which could be easily implemented into many existing pump-probe setups with minimal modifications for accurate, in situ characterization of both unknown pulses. This technique is tested on pairs of unknown pulses at wavelengths of 400/800 nm, and 266/400 nm. We measured the spectrogram of the pulse generated through FWM of the two unknown pulses by scanning the delay between two unknown pulses. The retrieval algorithm converges to accurately predict the intensity and the phase profiles of both unknown pulses with a trace error of < 1% and the accuracy is verified using an independent pulse characterization device.

Nambu, Noa (ORCID:0000000197303400)↗

Suppression of coherent interference to electric-field-induced second-harmonic (E-FISH) signals for the measurement of electric field in mesoscale confined geometries

We present spatially enhanced electric-field-induced second-harmonic (SEEFISH) generation with a chirped femtosecond beam for measurements of electric field in mesoscale confined geometries subject to destructive spurious second-harmonic generation (SHG). Spurious SHG is shown to interfere with the measured E-FISH signal coherently, and thus simple background subtraction is not sufficient for single-beam E-FISH approaches, especially in a confined system with a large surface-to-volume ratio. The results show that a chirped femtosecond beam is effective in preventing higher-order mixing and white light generation in windows near the beam focal point which further contaminates the SEEFISH signal. The successful measurements of electric field of a nanosecond dielectric barrier discharge in a test cell demonstrated that spurious SHG detected with a congruent traditional E-FISH approach can be eliminated using the SEEFISH approach.

Vorenkamp, Madeline↗

On-Demand Designing of Cathode Internal Surface Architecture for Dramatic Enhancement of SOFC Performance and Durability

This project is aimed to design and modify the internal surfaces of porous composite cathode from currently commercially viable Solid Oxide Fuel Cells (SOFCs), using additive manufacturing process of Atomic Layer Deposition (ALD). The material systems being investigated are commercial composite electrodes complex three-dimensional topographies. In term of the chemistry of the ALD layer applied on the internal surface of the porous cathode, this project has employed commercially relevant electrolyte, electrocatalyst and noble metal materials set. Such materials are fully compatible with the commercial fuel cells, and this project has developed special nanostructure on the surface of the commercial composite cathodes. The formation of the designed nanoarchitecture on the surface of SOFC cathode has been achieved through precise control of ALD parameters and their effect on overall cell performance and resultant electrochemical reaction mechanism of cathodes has been investigated through full cell electrochemical performance testing and nanostructure characterization by transmission electron microscopy (TEM). Under the support of this award, following has been achieved: (1). For cathode materials in solid oxide fuel cells (SOFCs), such as perovskite mixed conductor La 0.6 Sr 0.4 Co 0.2 Fe 0.8 O 3-x (LSCF), cation surface segregation and consequently losing conductivity and active sites for the oxygen reduction reaction (ORR) are problematic. To mitigate the cation segregation and enhance SOFC durability, further decorating the internal backbone surface using the desired electrocatalysts could be a promoting approach. Commonly, the cation segregation such as Sr is very volatile, so the effective surface decoration is ideally conformal. Nevertheless, the conformal surface coating would inevitably alter the ORR pathways that initially take place on the surface of the backbone. To reveal the impact of the conformal coating on both the catalytic activity and the conductivity of the cathode, the unary electrocatalyst of Pt or CoO x , was applied to the LSCF/SDC composite electrode of inherently functional SOFCs, respectively. Both ALD coating layers evolve strong interaction with the LSCF composite cathode. Upon operations, the Pt coating layer remains conformal on LSCF grain surfaces but turns into discrete particles on SDC grain surfaces. Meanwhile, CoO x conformal coating grows to be the discrete nanograins on both the LSCF and SDC grains. ALD coating of the cathode alone reduces the ohmic resistance up to 28 % for the entire cells. The increased conductivity induced by the ALD coating of Pt or CoO x is ascribed to different mechanisms. For the inherent functional SOFCs, the present study presents a novel and feasible approach to apply a conformal, dense coating layer on the surface of a mixed conductor, simultaneously increasing the conductivity and durability of the SOFC cathode. (2). High resistance of the oxygen electrode still significantly hinders the state-of-the-art Solid Oxide Fuel Cells (SOFCs). In particular, for an oxygen electrode consisting of mixed electronic and ionic conductors, such as perovskite lanthanum strontium cobalt ferrite (LSCF), it deteriorates due to its low chemical stability of the grain surface. Such degradation is often associated with the segregation of cations. To prevent the cation surface segregation and its resultant perovskite phase decomposition, we demonstrate a conformal ultra-thin (7-10 nm) surface heterogeneous coating layer consisting of subjacent discrete Pt nanoparticles capped with a superjacent fully dense conformal CoO x layer. The performance studies indicate the ALD coating reduces the cell series resistance by up to 40 %. The conformal CoO x layer consists of randomly orientated but single-layered nanograins, with high-density intergranular and surface grain boundaries serving as the electrochemical reaction sites and facilitating mass transport. The conformal coating layer appears to have successfully suppressed the Sr outward diffusion and confined the Sr enriched layer to a ~ 2 nm interface perovskite phase between the coating layer and the LSCF grain surface. Moreover, this ultra-thin Sr enriched perovskite layer presumably possesses high oxygen vacancy and high ionic conductivity and further imposes tensile strain to the LSCF grain surfaces. With the combination of a conformal CoO x nanoionics, Sr enriched layer, and its strained interface, the ALD coating induced surface layer is estimated to have a conductivity of ~ 1.27x10 4 S/cm, which is over two orders magnitude of that from LSCF at 750 ºC.

30 DIRECT ENERGY CONVERSION↗

Identification and mitigation of memory block timing issue in ITk ABCStar during ASIC production

The ABCStar is a mixed-signal front-end readout ASIC for the strips sensor portion of the ATLAS ITk detector being developed as part of the High-Luminosity LHC upgrade. In pre-production testing, a subtle design flaw was uncovered in the ABCStar that was reducing wafer yields in some manufactured lots from the expected 90% to as low as 2%. The root cause was determined to be a timing issue in the logic synthesized to control previously silicon proven memory blocks re-used for this ASIC. The solutions proposed included manufacturing process changes by the wafer foundry, changes to the operating parameters for the ABCStar in the detector, and the possibility that a redesign might be required. The two mitigation efforts were undertaken in parallel, with the process modification route a less desirable solution since already manufactured wafers would need to be scrapped in favour of the new ones. Based on a knowledge of the existing process, and testing done on the worst performing wafers, it was proposed that raising the core operating voltage of the ABCStar from 1.20V to 1.25V could address the timing issue by sufficiently speeding up its transistors. An extensive testing program that included the effects of temperature and radiation expected over the lifetime of the ITk detector was conducted to validate that approach. Those tests and studies proved that even the worst performing wafers would have yields over 80% with the 1.25V core voltage, and neither the modified process nor redesign would be required for ensuring reliable operation of the ITk. Based on testing, a further timing mitigation was implemented to provide an additional margin of reliability by increasing the duty cycle of the clock to the ABCStar. Testing of all ABCStar wafers has been completed and the production of the detector modules using these ASICs is now well underway as a result of the efforts detailed herein.

FOS: Physical sciences↗

EFFECTS OF RADIATION ON ESTABLISHED FORENSIC EVIDENCE CONTAINMENT METHODS

The Federal Bureau of Investigation (FBI) Laboratory is currently exploring needs and protocols for the storage of evidentiary items contaminated with radioactive material. While a large body of knowledge on the behavior of storage polymers in radiation fields exists, this knowledge has not been applied to the field of forensics and maintaining evidentiary integrity. The focus of this research was to evaluate the behavior of several traditional evidentiary containment polymers when exposed to significant alpha, beta, gamma, neutron and mixed radiation sources. Doses were designed to simulate exposures possible during storage of materials. Several products were found to be poorly suited for use in this specific application based on standardized mechanical testing results. Remaining products were determined to warrant further investigation for the storage of radiologically contaminated evidence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Task 2—Materials for Advanced Boiler and Oxy-combustion Systems (NETL-US),” a

Develop a method for determining the solubility of protective oxides (Fe2O3, Cr2O3 and NiO) in an ash exposed at a particular temperature and gas composition. Metal oxide powder (Cr2O3 and NiO) will be mixed with a synthetic ash, milled for complete mixing, exposed at a variety of exposure times, and removed for analysis. • A decision will be made based on the results on to going further with the next tasks. • Perform the solubility tests on synthetic ashes and ashes collected from various oxyfuel burner rigs. • Correlate the solubility with long term corrosion tests and variables from the b i 4 burner rig tests.

36 MATERIALS SCIENCE↗

Soil stabilization and pavement recycling with self-cementing coal fly ash

This manual provides design information for self-cementing coal fly ash as the sole stabilizing agent for a wide range of engineering applications. As in any process, the application of sound engineering practices, appropriate testing, and evaluation of fly ash quality and characteristics will lend themselves to successful projects using the guidelines in this manual. Topics discussed include: self-cementing coal fly ash characteristics; laboratory mix design; stabilization of clay soils; stabilisation of granular materials; construction considerations; high sulfate ash; environmental considerations for fly ash stabilization; design considerations; state specification/guidelines/standards; and a sample of a typical stabilization specification.

01 COAL, LIGNITE, AND PEAT↗

The aqueous corrosion behavior of technetium - Alloy and composite materials

Metal waste forms are under study as possible disposal forms for technetium and other fission products. The alloying of Tc is desirable to reduce the melting point of the Tc-containing metal waste form and potentially improve its corrosion resistance. Technetium-nickel composites were made by mixing the two metal powders and pressing the mixture to make a pellet. The as-pressed composite materials were compared to sintered composites and alloys of identical composition in electrochemical corrosion tests. As-pressed samples were not robust enough for fine polishing and only a limited number of corrosion tests were performed. Alloys and composites with 10 wt% Tc appear to be more corrosion resistant at open circuit than the individual components based on linear polarization resistance and polarization data. The addition of 10 wt% Tc to Ni appears beneficial at open circuit, but detrimental upon anodic polarization. Qualitatively, the polarizations of 10 wt% Tc alloys and composites appear like crude addition of Tc plus Ni. The 1 wt% Tc alloys behave like pure Ni, but some effect of Tc is seen upon polarization. Cathodic polarization of Tc by Ni appears feasible based on open circuit potential measurements, however, zero resistance ammetry and solution measurements are necessary to confirm cathodic protection.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hiding in the Shadow of the Upsilon: Ditaus from a Light Pseudoscalar

The CMS collaboration has reported a measurement of $Υ$ decays to ditaus using $61.9~{\rm fb}^{-1}$ of scouting data. If interpreted as the decay of $Υ(1S,2S,3S)$, the measured ditau rate is more than ten times that seen in the dimuon final states at the $\sim 3 σ$ level, and is likewise inconsistent with the branching ratios measured at $B$-factories. If confirmed with more data and at higher significance, such a violation of lepton flavor universality would necessitate new physics. In this Letter, we present a simple model with a light pseudoscalar coincidentally near the $Υ(1S)$ mass, which mixes with two Higgs doublets in the alignment limit. Such a particle naturally decays primarily to taus and evades all existing experimental constraints, while implying a number of predictions that can be tested in the near future.

Buckley, Matthew R. [Rutgers U., Piscataway]↗

The MESSy aerosol submodel MADE3 (v2.0b): description and a box model test

We introduce MADE3 (Modal Aerosol Dynamics model for Europe, adapted for global applications, 3rd generation; version: MADE3v2.0b), an aerosol dynamics submodel for application within the MESSy framework (Modular Earth Submodel System). MADE3 builds on the predecessor aerosol submodels MADE and MADE-in. Its main new features are the explicit representation of coarse mode particle interactions both with other particles and with condensable gases, and the inclusion of hydrochloric acid (HCl) / chloride (Cl) partitioning between the gas and condensed phases. The aerosol size distribution is represented in the new submodel as a superposition of nine lognormal modes: one for fully soluble particles, one for insoluble particles, and one for mixed particles in each of three size ranges (Aitken, accumulation, and coarse mode size ranges). In order to assess the performance of MADE3 we compare it to its predecessor MADE and to the much more detailed particle-resolved aerosol model PartMC-MOSAIC in a box model simulation of an idealised marine boundary layer test case. MADE3 and MADE results are very similar, except in the coarse mode, where the aerosol is dominated by sea spray particles. Cl is reduced in MADE3 with respect to MADE due to the HCl / Cl partitioning that leads to Cl removal from the sea spray aerosol in our test case. Additionally, the aerosol nitrate concentration is higher in MADE3 due to the condensation of nitric acid on coarse mode particles. MADE3 and PartMC-MOSAIC show substantial differences in the fine particle size distributions (sizes ≲ 2 μm) that could be relevant when simulating climate effects on a global scale. Nevertheless, the agreement between MADE3 and PartMC-MOSAIC is very good when it comes to coarse particle size distributions (sizes ≳ 2 μm), and also in terms of aerosol composition. Finally, considering these results and the well-established ability of MADE in reproducing observed aerosol loadings and composition, MADE3 seems suitable for application within a global model.

Kaiser, J. C.↗

WTP Waste Feed Qualification: Hydrogen Generation Rate Measurement Apparatus Testing Report

The generation rate of hydrogen gas in the Hanford tank waste will be measured during the qualification of the staged tank waste for processing in the Hanford Tank Waste Treatment and Immobilization Plant. Based on a review of past practices in measurement of the hydrogen generation, an apparatus to perform this measurement has been designed and tested for use during waste feed qualification. The hydrogen generation rate measurement apparatus (HGRMA) described in this document utilized a 100 milliliter sample in a continuously-purged, continuously-stirred vessel, with measurement of hydrogen concentration in the vent gas. The vessel and lid had a combined 220 milliliters of headspace. The vent gas system included a small condenser to prevent excessive evaporative losses from the sample during the test, as well as a demister and filter to prevent particle migration from the sample to the gas chromatography system. The gas chromatograph was an on line automated instrument with a large-volume sample-injection system to allow measurement of very low hydrogen concentrations. This instrument automatically sampled the vent gas from the hydrogen generation rate measurement apparatus every five minutes and performed data regression in real time. The fabrication of the hydrogen generation rate measurement apparatus was in accordance with twenty three (23) design requirements documented in the conceptual design package, as well as seven (7) required developmental activities documented in the task plan associated with this work scope. The HGRMA was initially tested for proof of concept with physical simulants, and a remote demonstration of the system was performed in the Savannah River National Laboratory Shielded Cells Mockup Facility. Final verification testing was performed using non-radioactive simulants of the Hanford tank waste. Three different simulants were tested to bound the expected rheological properties expected during waste feed qualification testing. These simulants were tested at different temperatures using purge gas spiked with varying amounts of hydrogen to provide verification that the system could accurately measure the hydrogen in the vent gas at steady state.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Searching for Sterile Neutrinos In the NOvA Experiment and Measurements of Hadronic Energy Response with NOvA Test Beam Data

The NOvA (NuMI Off-Axis electron neutrino Appearance) experiment is a long-baseline neutrino oscillation experiment composed of two functionally identical detectors: a 300-ton Near Detector and a 14-kton Far Detector, separated by 809 km and placed 14 mrad off the axis of the NuMI neutrino beam created at Fermilab. This configuration enables NOvA’s rich neutrino physics program, which includes measuring neutrino mixing parameters, determining the neutrino mass hierarchy, probing CP violation in the leptonic sector, studying neutrino cross sections, searching for sterile neutrinos, and more.\\ In this thesis I will present two independent analyses developed within the NOvA experiment. The first is a search for light sterile neutrino oscillations in the 3+1 framework using $\nu_\mu$-CC and NC samples from the NOvA Near and Far Detectors. Light sterile neutrinos are hypothetical neutral leptons that do not participate in the weak interactions but can mix with the three known active neutrinos: $\nu_e$, $\nu_\mu$, and $\nu_\tau$. Anomalous results, such as $\nu_e$/$\bar{\nu}e$ appearance in a $\nu_\mu$ ($\bar{\nu}_\mu$) beam observed by the MiniBooNE and LSND experiments, can be explained by the existence of sterile neutrinos. Thus, proving the existence of this type of neutrino is essential. The latest results of these searches in the NOvA experiment, along with contributions to this effort, will be presented.\\ The second is the first measurement of the pion energy response using data from the NOvA Test Beam experiment. The NOvA Test Beam experiment, deployed at Fermilab, uses a scaled-down 30-ton NOvA detector to analyze tagged beamline particles. The beamline can select and identify electrons, muons, pions, kaons, and protons with momenta ranging from 0.4 to 1.4 GeV/c. Pions are an important component of the hadronic system in neutrino interactions, and understanding how the detector responds to these particles is crucial for the validation of the simulation and the reduction of detector calibration uncertainties, which remain one of the largest systematic uncertainties in NOvA analyses.

Dueñas Tonguino, David Francisco [Cincinnati U.] (↗

Dry particle generation with a 3-D printed fluidized bed generator

Here we describe the design and testing of PRIZE (PRinted fluidIZed bed gEnerator), a compact fluidized bed aerosol generator manufactured using stereolithography (SLA) printing. Dispersing small quantities of powdered materials – due to either rarity or expense – is challenging due to a lack of small, low-cost dry aerosol generators. With this as motivation, we designed and built a generator that uses a mineral dust or other dry powder sample mixed with bronze beads that sit atop a porous screen. A particle-free airflow is introduced, dispersing the sample as airborne particles. Total particle number concentrations and size distributions were measured during different stages of the assembling process to show that the SLA 3-D printed generator did not generate particles until the mineral dust sample was introduced. Time-series measurements with Arizona Test Dust (ATD) showed stable total particle number concentrations of 10–150 cm -3 , depending on the sample mass, from the sub- to super-micrometer size range. Additional tests with collected soil dust samples are also presented. PRIZE is simple to assemble, easy to clean, inexpensive and deployable for laboratory and field studies that require dry particle generation.

54 ENVIRONMENTAL SCIENCES↗

GLYCOLIC-FORMIC ACID FLOWSHEET FINAL REPORT FOR DOWNSELECTION DECISION

Flowsheet testing was performed to develop the nitric-glycolic-formic acid flowsheet (referred to as the glycolic-formic flowsheet throughout the rest of the report) as an alternative to the nitric/formic flowsheet currently being processed at the DWPF. This new flowsheet has shown that mercury can be removed in the Sludge Receipt and Adjustment Tank (SRAT) with minimal hydrogen generation. All processing objectives were also met, including greatly reducing the Slurry Mix Evaporator (SME) product yield stress as compared to the baseline nitric/formic flowsheet. Forty-six runs were performed in total, including the baseline run and the melter feed preparation runs. Significant results are summarized. The baseline nitric/formic flowsheet run, using the SB6 simulant produced by Harrell was extremely difficult to process successfully under existing DWPF acceptance criteria with this simulant at the HM levels of noble metals. While nitrite was destroyed and mercury was removed to near the DWPF limit, the rheology of the SRAT and SME products were well above design basis and hydrogen generation far exceeded the DWPF SRAT limit. In addition, mixing during the SME cycle was very poor. In this sense, the nitric/glycolic/formic acid flowsheet represents a significant upgrade over the current flowsheet. Mercury was successfully removed with almost no hydrogen generation and the SRAT and SME products yield stresses were within process limits or previously processed ranges. The glycolic-formic flowsheet has a very wide processing window. Testing was completed from 100% to 200% of acid stoichiometry and using a glycolic-formic mixture from 40% to 100% glycolic acid. The testing met all processing requirements throughout these processing windows. This should allow processing at an acid stoichiometry of 100% and a glycolic-formic mixture of 80% glycolic acid with minimal hydrogen generation. It should also allow processing endpoints in the SRAT and SME at significantly higher total solids content and may be effective at acid stoichiometries below 100%, although no testing was performed below 100% acid stoichiometry. There are several issues related to the development of the glycolic-formic flowsheet. First, the measurement of anions using the new glycolate anion procedure likely needs to be optimized to improve the accuracy of the anions important to DWPF processing and REDOX prediction. Second, the existing REDOX equation with an added term for glycolate did not accurately predict the glass REDOX for the glycolic-formic flowsheet. Improvement of the anion measurement or modification of the REDOX methodology or equation may be necessary to improve the REDOX prediction. Last, the glycolic-formic flowsheet dissolves a number of metals, including iron. This leads to a thinner slurries but also dissolves up a portion of the iron, which is currently used for criticality control. It is recommended that DWPF continue to support development of the glycolic-formic flowsheet. This flowsheet meets or outperforms the baseline flowsheet in off-gas generation, mercury removal, product rheology and general ease of processing. Additional testing is in progress to demonstrate the effectiveness of the nitric-glycolic-formic flowsheet in processing a wide sludge processing window using the matrix sludge simulants.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

First Ever Polymer Flood Field Pilot to Enhance the Recovery of Heavy Oils on Alaska North Slope – Producer Responses and Operational Lessons Learned

The US Department of Energy and Hilcorp Alaska, LLC are jointly cosponsoring a field pilot project entitled “First Ever Field Pilot on Alaska’s North Slope to Validate the Use of Polymer Floods for Heavy Oil Enhanced Oil Recovery (EOR).” The objective of this pilot is to perform a field experiment to validate the use of an advanced polymer flooding technology to unlock the vast heavy oil resources on Alaska North Slope (ANS). Two pairs of horizontal injection and production wells have been deployed in an isolated fault block of the Schrader Bluff heavy oil reservoir at the Milne Point Field to conduct a polymer flood pilot which was designed to acquire field performance data to optimize polymer flood design in the Schrader Bluff heavy oil reservoirs on ANS. Hydrolyzed polyacrylamide (HPAM) polymer injection started on August 28, 2018 using a custom made polymer mixing and pumping unit. Polymer solution properties such as concentration, viscosity, and filter ratio, have been closely monitored and adjusted as necessary. Operational procedures have been improved to ensure adequate injectivity and polymer propagation through the formation. Oil and water production is tested frequently to monitor water cut performance, and produced water is sampled and analyzed for polymer content. Tracers were pumped pre and post polymer injection startup to compare polymer flood breakthrough timing and sweep efficiency. Polymer injectivity of the horizontal wells drilled in the Schrader Bluff NB sand is found to be sufficient to replace the reservoir production voidage although there were some declines as high viscosity polymer swept the near wellbore region. Production data show significant reduction in water cut and the oil production rate has stabilized. No polymer production has been confirmed from the two horizontal producers after 22 months of polymer injection into the two supporting horizontal injectors. Tracer data show very low sweep efficiencies with waterflood alone, whereas significant improvement has been achieved with polymer flood. Many operational lessons have been learned and improvements have been made regarding polymer mixing, pumping, and onsite quality control, particularly in a challenging Arctic environment. Adequate polymer injection rate can be achieved with diligent monitoring and quality assurance of the properties of the injected polymer solution.

Ning, Samson↗