Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear Data Evaluation Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Development of a Discrepancy Checker for the Digital Twin in a Supervisory Control System for a Thermal Energy Delivery System

Defined as a virtual representation of a physical object, process, or service, and used to support real-world decision-making, a digital twin (DT) can be utilized to combine classical and novel frameworks in sensors, state predictions, and multi-input/multi-output systems, and to enable optimal autonomous operations. However, a DT’s usefulness largely depends on its ability to adequately mirror the state of its physical counterpart, and this adequacy should be reflected by the level of uncertainty in the underlying simulation models when estimating and predicting quantities of interest (QOIs). Moreover, simulation models in a DT may involve multiple fidelities of representations—ranging from physics-based models to data-driven ones—but classical uncertainty quantification (UQ) methods struggle to handle numerous uncertainty sources, nor are they designed for real-time applications. This work presents a UQ-based discrepancy checking and diagnosis tool for a DT-based supervisory control system applied to a thermal energy delivery system (TEDS) at Idaho National Laboratory. The discrepancy checker was developed using metadata from an automated DT development process, and these metadata included different combinations of physical model forms and model parameters, training data and hyperparameters for surrogate models, and design parameters for supervisory control systems. Next, correlations between the uncertainty results and the metadata were established and then applied to the DT operations. The discrepancy checker evaluates the discrepancies between model predictions from virtual and sensor measurements and backtraces them to the corresponding major sources of uncertainty. The discrepancy checker showed reasonable performance in detecting discrepancies and diagnosing sources of uncertainty in testing scenarios.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Collaboration versus communication: The Department of Energy's Amchitka Island and the Aleut Community

Increasingly managers and scientists are recognizing that solving environmental problems requires the inclusion of a wide range of disciplines, governmental agencies, Native American tribes, and other stakeholders. Usually such inclusion involves communication at the problem-formulation phase, and at the end to report findings. This paper examines participatory research, the differences between the traditional stakeholder involvement method of communication (often one-way, at the beginning and the end), compared to full collaboration, where parties are actively involved in the scientific process. Using the Department of Energy's (DOE) Amchitka Island in the Aleutians as a case study, we demonstrate that the inclusion of Aleut people throughout the process resulted in science that was relevant not only to the agency's needs and to the interested and affected parties, but that led to a solution. Amchitka Island was the site of three underground nuclear tests from 1965 to 1971, and virtually no testing of radionuclide levels in biota, subsistence foods, or commercial fish was conducted after the 1970s. When DOE announced plans to close Amchitka, terminating its managerial responsibility, without any further testing of radionuclide levels in biota, there was considerable controversy, which resulted in the development of a Science Plan to assess the potential risks to the marine environment from the tests. The Consortium for Risk Evaluation with Stakeholder Participation (CRESP) was the principle entity that developed and executed the science plan. Unlike traditional science, CRESP embarked on a process to include the Alaskan Natives of the Aleutian Islands (Aleuts), relevant state and federal agencies, and other stakeholders at every phase. Aleuts were included in the problem-formulation, research design refinement, the research, analysis of data, dissemination of research findings, and public communication. This led to agreement with the results, and to developing a path forward (production of a biomonitoring plan designed to provide early warning of any future radionuclide leakage and ecosystem/human health risks). The process outlined was successful in resolving a previously contentious situation by inclusion and collaboration with the Aleuts, among others, and could be usefully applied elsewhere to complex environmental problems where severe data gaps exist.

54 ENVIRONMENTAL SCIENCES↗

PRACTICAL METHOD FOR ESTIMATING NEUTRON CROSS SECTION COVARIANCES IN THE RESONANCE REGION

Recent evaluations of neutron cross section covariances in the resolved resonance region reveal the need for further research in this area. Major issues include declining uncertainties in multigroup representations and proper treatment of scattering radius uncertainty. To address these issues, the present work introduces a practical method based on kernel approximation using resonance parameter uncertainties from the Atlas of Neutron Resonances. Analytical expressions derived for average cross sections in broader energy bins along with their sensitivities provide transparent tool for determining cross section uncertainties. The role of resonance-resonance and bin-bin correlations is specifically studied. As an example we apply this approach to estimate (n,{gamma}) and (n,el) covariances for the structural material {sup 55}Mn.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reaction rate sensitivity of 44Ti production in massive stars and implications of a thick target yield measurement of 40Ca(alpha,gamma)44Ti

We evaluate two dominant nuclear reaction rates and their uncertainties that affect {sup 44}Ti production in explosive nucleosynthesis. Experimentally we develop thick-target yields for the {sup 40}Ca({alpha},{gamma}){sup 44}Ti reaction at E{sub {alpha}} = 4.13, 4.54, and 5.36 MeV using {gamma}-ray spectroscopy. At the highest beam energy, we also performed an activation measurement which agrees with the thick target result. From the measured yields a stellar reaction rate was developed that is smaller than current statistical-model calculations and recent experimental results, which would suggest lower {sup 44}Ti production in scenarios for the {alpha}-rich freeze out. Special attention has been paid to assessing realistic uncertainties of stellar reaction rates produced from a combination of experimental and theoretical cross sections. With such methods, we also develop a re-evaluation of the {sup 44}Ti({alpha},p){sup 47}V reaction rate. Using these two rates we carry out a sensitivity survey of {sup 44}Ti synthesis in eight expansions representing peak temperature and density conditions drawn from a suite of recent supernova explosion models. Our results suggest that the current uncertainty in these two reaction rates could lead to as large an uncertainty in {sup 44}Ti synthesis as that produced by different treatments of stellar physics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantitative modeling of the accuracy in registering preoperative patient-specific anatomic models into left atrial cardiac ablation procedures

Purpose: In cardiac ablation therapy, accurate anatomic guidance is necessary to create effective tissue lesions for elimination of left atrial fibrillation. While fluoroscopy, ultrasound, and electroanatomic maps are important guidance tools, they lack information regarding detailed patient anatomy which can be obtained from high resolution imaging techniques. For this reason, there has been significant effort in incorporating detailed, patient-specific models generated from preoperative imaging datasets into the procedure. Both clinical and animal studies have investigated registration and targeting accuracy when using preoperative models; however, the effect of various error sources on registration accuracy has not been quantitatively evaluated. Methods: Data from phantom, canine, and patient studies are used to model and evaluate registration accuracy. In the phantom studies, data are collected using a magnetically tracked catheter on a static phantom model. Monte Carlo simulation studies were run to evaluate both baseline errors as well as the effect of different sources of error that would be present in a dynamicin vivo setting. Error is simulated by varying the variance parameters on the landmark fiducial, physical target, and surface point locations in the phantom simulation studies. In vivo validation studies were undertaken in six canines in which metal clips were placed in the left atrium to serve as ground truth points. A small clinical evaluation was completed in three patients. Landmark-based and combined landmark and surface-based registration algorithms were evaluated in all studies. In the phantom and canine studies, both target registration error and point-to-surface error are used to assess accuracy. In the patient studies, no ground truth is available and registration accuracy is quantified using point-to-surface error only. Results: The phantom simulation studies demonstrated that combined landmark and surface-based registration improved landmark-only registration provided the noise in the surface points is not excessively high. Increased variability on the landmark fiducials resulted in increased registration errors; however, refinement of the initial landmark registration by the surface-based algorithm can compensate for small initial misalignments. The surface-based registration algorithm is quite robust to noise on the surface points and continues to improve landmark registration even at high levels of noise on the surface points. Both the canine and patient studies also demonstrate that combined landmark and surface registration has lower errors than landmark registration alone. Conclusions: In this work, we describe a model for evaluating the impact of noise variability on the input parameters of a registration algorithm in the context of cardiac ablation therapy. The model can be used to predict both registration error as well as assess which inputs have the largest effect on registration accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validations of calibration-free measurements of electron temperature using double-pass Thomson scattering diagnostics from theoretical and experimental aspects

This paper evaluates the accuracy of electron temperature measurements and relative transmissivities of double-pass Thomson scattering diagnostics. The electron temperature (T{sub e}) is obtained from the ratio of signals from a double-pass scattering system, then relative transmissivities are calculated from the measured T{sub e} and intensity of the signals. How accurate the values are depends on the electron temperature (T{sub e}) and scattering angle (θ), and therefore the accuracy of the values was evaluated experimentally using the Large Helical Device (LHD) and the Tokyo spherical tokamak-2 (TST-2). Analyzing the data from the TST-2 indicates that a high T{sub e} and a large scattering angle (θ) yield accurate values. Indeed, the errors for scattering angle θ = 135° are approximately half of those for θ = 115°. The method of determining the T{sub e} in a wide T{sub e} range spanning over two orders of magnitude (0.01–1.5 keV) was validated using the experimental results of the LHD and TST-2. A simple method to provide relative transmissivities, which include inputs from collection optics, vacuum window, optical fibers, and polychromators, is also presented. The relative errors were less than approximately 10%. Numerical simulations also indicate that the T{sub e} measurements are valid under harsh radiation conditions. This method to obtain T{sub e} can be considered for the design of Thomson scattering systems where there is high-performance plasma that generates harsh radiation environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic gating window for compensation of baseline shift in respiratory-gated radiation therapy

Purpose: To analyze and evaluate the necessity and use of dynamic gating techniques for compensation of baseline shift during respiratory-gated radiation therapy of lung tumors. Methods: Motion tracking data from 30 lung tumors over 592 treatment fractions were analyzed for baseline shift. The finite state model (FSM) was used to identify the end-of-exhale (EOE) breathing phase throughout each treatment fraction. Using duty cycle as an evaluation metric, several methods of end-of-exhale dynamic gating were compared: An a posteriori ideal gating window, a predictive trend-line-based gating window, and a predictive weighted point-based gating window. These methods were evaluated for each of several gating window types: Superior/inferior (SI) gating, anterior/posterior beam, lateral beam, and 3D gating. Results: In the absence of dynamic gating techniques, SI gating gave a 39.6% duty cycle. The ideal SI gating window yielded a 41.5% duty cycle. The weight-based method of dynamic SI gating yielded a duty cycle of 36.2%. The trend-line-based method yielded a duty cycle of 34.0%. Conclusions: Dynamic gating was not broadly beneficial due to a breakdown of the FSM's ability to identify the EOE phase. When the EOE phase was well defined, dynamic gating showed an improvement over static-window gating.

60 APPLIED LIFE SCIENCES↗

Are We Appropriately Selecting Therapy For Patients With Cervical Cancer? Longitudinal Patterns-of-Care Analysis for Stage IB-IIB Cervical Cancer

Purpose: We performed a patterns-of-care analysis evaluating the effects of newer technology and recent research findings on treatment decisions over 26 years to determine whether patients with cervical cancer are being appropriately selected for treatment to optimize the therapeutic ratio. Methods and Materials: A retrospective analysis was conducted using the Surveillance, Epidemiology and End Results (SEER) program from 1983 to 2009. We identified 10,933 women with stage IB-IIB cervical carcinoma. Results: Of the 10,933 subjects identified, 40.1% received surgery, 26.8% received radiation (RT), and 33.1% received surgery plus RT. RT use increased after 2000 compared to prior to 2000, with a corresponding decrease in surgery and surgery plus RT. Among patients with risk factors including tumor size >4 cm, positive parametria, and positive lymph nodes, declining use of surgery plus RT was observed. However, 23% of patients with tumors >4 cm, 20% of patients with positive parametria, and 55% of node-positive patients continued to receive surgery plus RT as of 2009. Factors associated with increased use of surgery plus RT included patient age <50 and node-positive status. Conclusions: In this largest patterns-of-care analysis to date for patients with locally advanced cervical cancer, we found a substantial proportion of patients continue to undergo surgery followed by radiation, despite randomized data supporting the use of definitive radiation therapy, with lower morbidity than surgery and radiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Doses to Carotid Arteries After Modern Radiation Therapy for Hodgkin Lymphoma: Is Stroke Still a Late Effect of Treatment?

Purpose: Hodgkin lymphoma (HL) survivors are at an increased risk of stroke because of carotid artery irradiation. However, for early-stage HL involved node radiation therapy (INRT) reduces the volume of normal tissue exposed to high doses. Here, we evaluate 3-dimensional conformal radiation therapy (3D-CRT), volumetric-modulated arc therapy (VMAT), and proton therapy (PT) delivered as INRT along with the extensive mantle field (MF) by comparing doses to the carotid arteries and corresponding risk estimates. Methods and Materials: We included a cohort of 46 supradiaphragmatic stage I-II classical HL patients. All patients were initially treated with chemotherapy and INRT delivered as 3D-CRT (30 Gy). For each patient, we simulated MF (36 Gy) and INRT plans using VMAT and PT (30 Gy). Linear dose-response curves for the 20-, 25-, and 30-year risk of stroke were derived from published HL data. Risks of stroke with each technique were calculated for all patients. Statistical analyses were performed with repeated measures analysis of variance. Results: The mean doses to the right and left common carotid artery were significantly lower with modern treatment compared with MF, with substantial patient variability. The estimated excess risk of stroke after 20, 25, and 30 years was 0.6%, 0.86%, and 1.3% for 3D-CRT; 0.67%, 0.96%, and 1.47% for VMAT; 0.61%, 0.96%, and 1.33% for PT; and 1.3%, 1.72%, and 2.61% for MF. Conclusions: INRT reduces the dose delivered to the carotid arteries and corresponding estimated risk of stroke for HL survivors. Even for the subset of patients with lymphoma close to the carotid arteries, the estimated risk is low.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Individualized Positron Emission Tomography–Based Isotoxic Accelerated Radiation Therapy Is Cost-Effective Compared With Conventional Radiation Therapy: A Model-Based Evaluation

Purpose: To evaluate long-term health effects, costs, and cost-effectiveness of positron emission tomography (PET)-based isotoxic accelerated radiation therapy treatment (PET-ART) compared with conventional fixed-dose CT-based radiation therapy treatment (CRT) in non-small cell lung cancer (NSCLC). Methods and Materials: Our analysis uses a validated decision model, based on data of 200 NSCLC patients with inoperable stage I-IIIB. Clinical outcomes, resource use, costs, and utilities were obtained from the Maastro Clinic and the literature. Primary model outcomes were the difference in life-years (LYs), quality-adjusted life-years (QALYs), costs, and the incremental cost-effectiveness and cost/utility ratio (ICER and ICUR) of PET-ART versus CRT. Model outcomes were obtained from averaging the predictions for 50,000 simulated patients. A probabilistic sensitivity analysis and scenario analyses were carried out. Results: The average incremental costs per patient of PET-ART were €569 (95% confidence interval [CI] €−5327-€6936) for 0.42 incremental LYs (95% CI 0.19-0.61) and 0.33 QALYs gained (95% CI 0.13-0.49). The base-case scenario resulted in an ICER of €1360 per LY gained and an ICUR of €1744 per QALY gained. The probabilistic analysis gave a 36% probability that PET-ART improves health outcomes at reduced costs and a 64% probability that PET-ART is more effective at slightly higher costs. Conclusion: On the basis of the available data, individualized PET-ART for NSCLC seems to be cost-effective compared with CRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Mechanical Recanalisation After Intravenous Thrombolysis in Acute Anterior Circulation Stroke: The Impact of a New Temporary Stent

Purpose: Treatment of acute stroke by endovascular mechanical recanalisation (EMR) has shown promising results and continues to be further refined. We evaluated the impact of a temporary stent compared with our results using other mechanical devices. Materials and Methods: We analysed clinical and radiological data of all patients who were treated by EMR after intravenous thrombolysis for acute carotid T- and middle-cerebral artery (M1) occlusions at our centre between 2007 and 2011. A comparison was performed between those patients in whom solely the stent-retriever was applied (group S) and those treated with other devices (group C). Results: We identified 14 patients for group S and 16 patients for group C. Mean age, National Institute of Health Stroke Scale score, and time to treatment were 67.1 years and 16.5 and 4.0 h for group S and 61.1 years and 17.6 and 4.5 h for group C, respectively. Successful recanalisation (thrombolysis in cerebral infarction scores {>=}IIb) was achieved in 93% of patients in group S and 56% of patients in group C (P < 0.05). Mean recanalisation times for M1 occlusions were 23 min (group S) and 29 min (group C) and for carotid-T occlusions were 39 min (group S) and 50 min (group C), and 45% of the patients in group S and 33% in group C had a favourable outcome (Modified Rankin Scale score {<=}2). Conclusion: The findings suggest an improvement in recanalisation success by the application of a temporary stent compared with previously used devices. These results are to be confirmed by larger studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Survival Impact of Adjuvant Radiation Therapy in Masaoka Stage II to IV Thymomas: A Systematic Review and Meta-analysis

Purpose: To evaluate the survival impact of postoperative radiation therapy (PORT) in stage II to IV thymomas, using systematic review and meta-analysis. Methods and Materials: A database search was conducted with EMBASE, PubMed, Web of Science, Cochrane Library, and Ovid from inception to August 2015. Thymic carcinomas were excluded, and studies comparing overall survival (OS) with and without PORT in thymomas were included. The hazard ratios (HRs) of OS were extracted, and a random-effects model was used in the pooled analysis. Results: Seven retrospective series with a total of 1724 patients were included and analyzed. Almost all of the patients underwent macroscopically complete resection, and thymoma histology was confirmed by the World Health Organization criteria. In the overall analysis of stage II to IV thymomas, OS was not altered with the receipt of PORT (HR 0.79, 95% confidence interval [CI] 0.58-1.08). Although PORT was not associated with survival difference in Masaoka stage II disease (HR 1.45, 95% CI 0.83-2.55), improved OS was observed with the addition of PORT in the discrete pooled analysis of stage III to IV (HR 0.63, 95% CI 0.40-0.99). Significant heterogeneity and publication bias were not found in the analyses. Conclusions: From the present meta-analysis of sole primary thymomas, we suggest the potential OS benefit of PORT in locally advanced tumors with macroscopically complete resection, but not in stage II disease. Further investigations with sufficient survival data are needed to establish detailed treatment indications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Evaluation of Two Internal Surrogates for Determining the Three-Dimensional Position of Peripheral Lung Tumors

Purpose: Both carina and diaphragm positions have been used as surrogates during respiratory-gated radiotherapy. We studied the correlation of both surrogates with three-dimensional (3D) tumor position. Methods and Materials: A total of 59 repeat artifact-free four-dimensional (4D) computed tomography (CT) scans, acquired during uncoached breathing, were identified in 23 patients with Stage I lung cancer. Repeat scans were co-registered to the initial 4D CT scan, and tumor, carina, and ipsilateral diaphragm were manually contoured in all phases of each 4D CT data set. Correlation between positions of carina and diaphragm with 3D tumor position was studied by use of log-likelihood ratio statistics. Models to predict 3D tumor position from internal surrogates at end inspiration (EI) and end expiration (EE) were developed, and model accuracy was tested by calculating SDs of differences between predicted and actual tumor positions. Results: Motion of both the carina and diaphragm significantly correlated with tumor motion, but log-likelihood ratios indicated that the carina was more predictive for tumor position. When craniocaudal tumor position was predicted by use of craniocaudal carina positions, the SDs of the differences between the predicted and observed positions were 2.2 mm and 2.4 mm at EI and EE, respectively. The corresponding SDs derived with the diaphragm positions were 3.7 mm and 3.9 mm at EI and EE, respectively. Prediction errors in the other directions were comparable. Prediction accuracy was similar at EI and EE. Conclusions: The carina is a better surrogate of 3D tumor position than diaphragm position. Because residual prediction errors were observed in this analysis, additional studies will be performed using audio-coached scans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

International Medical Graduates in Radiation Oncology: Historical Trends and Comparison With Other Medical Specialties

Purpose: This is the first National Resident Matching Program analysis evaluating historical patterns of international medical graduates (IMGs) in radiation oncology (RO) and providing comparison with American (MD) medical graduates (AMGs), osteopathic students (DOs), unfilled positions, and other specialties. Methods and Materials: National Resident Matching Program data for IMGs were available from 2003 to 2015, with limited data for other specialty matches. The following RO-specific figures were obtained per year: total positions available; total matched positions; number of unfilled positions; and number of IMG, AMG, and DO matches. In addition, the number of IMG matches and total matched positions were obtained for 19 other specialties. Fisher exact tests and χ{sup 2} tests were considered significant at α <.05. Results: From 2010 to 2015, 0.8% of RO matches were IMGs, a decline from 2.4% in 2003 to 2009 (P=.006). Proportions of DO matches during these intervals increased by 40% (from 1.0% to 1.4%), significantly lower than IMGs for 2003 to 2009 (P=.03) but not 2010 to 2015 (P=.26). From 2003 to 2015, the percentage of IMG matches, at 1.5%, was significantly lower than the percentage of unfilled seats, at 3.5% (P<.001). In comparison with other specialties (2003-2015), RO had the fewest IMG matches (1.5%), followed by otolaryngology (1.9%) and orthopedics (2.2%); specialties with the highest IMG proportions were internal medicine (37.1%), family medicine (35.7%), and neurology (31.1%). Conclusions: Presently, IMGs represent <1% of RO matches, the lowest among major specialties. There are several speculative factors associated with this low proportion. There are significantly more unfilled positions than those filled by IMGs; programs at risk of not matching could weigh the advantages and disadvantages of interviewing IMGs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cone-Beam CT-Based Delineation of Stereotactic Lung Targets: The Influence of Image Modality and Target Size on Interobserver Variability

Purpose: It is generally agreed that the safe implementation of stereotactic body radiotherapy requires image guidance. The aim of this work was to assess interobserver variability in the delineation of lung lesions on cone-beam CT (CBCT) images compared with CT-based contouring for adaptive stereotactic body radiotherapy. The influence of target size was also evaluated. Methods and Materials: Eight radiation oncologists delineated gross tumor volumes in 12 patient cases (non-small cell lung cancer I-II or solitary metastasis) on planning CTs and on CBCTs. Cases were divided into two groups with tumor diameters of less than (Group A) or more than 2 cm (Group B). Comparison of mean volumes delineated by all observers and range and coefficient of variation were reported for each case and image modality. Interobserver variability was assessed by means of standard error of measurement, conformity index (CI), and its generalized observer-independent approach. The variance between single observers on CT and CBCT images was measured via interobserver reliability coefficient. Results: Interobserver variability on CT images was 17% with 0.79 reliability, compared with 21% variability on CBCT and 0.76 reliability. On both image modalities, values of the intraobserver reliability coefficient (0.99 for CT and 0.97 for CBCT) indicated high reproducibility of results. In general, lower interobserver agreement was observed for small lesions (CI{sub genA} = 0.62 {+-} 0.06 vs. CI{sub genB} = 0.70 {+-} 0.03, p < 0.05). The analysis of single patient cases revealed that presence of spicules, diffuse infiltrations, proximity of the tumors to the vessels and thoracic wall, and respiration motion artifacts presented the main sources of the variability. Conclusion: Interobserver variability for Stage I-II non-small cell lung cancer and lung metastasis was slightly higher on CBCT compared with CT. Absence of significant differences in interobserver variability suggests that CBCT imaging provides an effective tool for tumor localization, and image data could be also used for target volume delineation purposes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Field-in-Field Technique for Total Body Irradiation

Purpose: To evaluate the clinical use of a field-in-field (FIF) technique for total body irradiation (TBI) using a treatment-planning system (TPS) and to verify TPS results with in vivo dose measurements using metal-oxide-semiconductor field-effect transistor (MOSFET) detectors. Methods and Materials: Clinical and dosimetric data of 10 patients treated with TBI were assessed. Certain radiation parameters were measured using homogenous and regular phantoms at an extended distance of 380 cm, and the results were compared with data from a conventional standard distance of 100 cm. Additionally, dosimetric validation of TPS doses was performed with a Rando phantom using manual calculations. A three-dimensional computed tomography plan was generated involving 18-MV photon beams with a TPS for both open-field and FIF techniques. The midline doses were measured at the head, neck, lung, umbilicus, and pelvis for both open-field and FIF techniques. Results: All patients received planned TBI using the FIF technique with 18-MV photon energies and 2 Gy b.i.d. on 3 consecutive days. The difference in tissue maximum ratios between the extended and conventional distances was <2%. The mean deviation of manual calculations compared with TPS data was +1.6% (range, 0.1-2.4%). A homogenous dose distribution was obtained with 18-MV photon beams using the FIF technique. The mean lung dose for the FIF technique was 79.2% (9.2 Gy; range, 8.8-9.7 Gy) of the prescribed dose. The MOSFET readings and TPS doses in the body were similar (percentage difference range, -0.5% to 2.5%) and slightly higher in the shoulder and lung (percentage difference range, 4.0-5.5%). Conclusion: The FIF technique used for TBI provides homogenous dose distribution and is feasible, simple, and spares time compared with more-complex techniques. The TPS doses were similar to the midline doses obtained from MOSFET readings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of the Accuracy of a 3D Surface Imaging System for Patient Setup in Head and Neck Cancer Radiotherapy

Purpose: To evaluate the accuracy of three-dimensional (3D) surface imaging system (AlignRT) registration algorithms for head-and-neck cancer patient setup during radiotherapy. Methods and Materials: Eleven patients, each undergoing six repeated weekly helical computed tomography (CT) scans during treatment course (total 77 CTs including planning CT), were included in the study. Patient surface images used in AlignRT registration were not captured by the 3D cameras; instead, they were derived from skin contours from these CTs, thereby eliminating issues with immobilization masks. The results from surface registrations in AlignRT based on CT skin contours were compared to those based on bony anatomy registrations in Pinnacle{sup 3}, which was considered the gold standard. Both rigid and nonrigid types of setup errors were analyzed, and the effect of tumor shrinkage was investigated. Results: The maximum registration errors in AlignRT were 0.2 Degree-Sign for rotations and 0.7 mm for translations in all directions. The rigid alignment accuracy in the head region when applied to actual patient data was 1.1 Degree-Sign , 0.8 Degree-Sign , and 2.2 Degree-Sign in rotation and 4.5, 2.7, and 2.4 mm in translation along the vertical, longitudinal, and lateral axes at 90% confidence level. The accuracy was affected by the patient's weight loss during treatment course, which was patient specific. Selectively choosing surface regions improved registration accuracy. The discrepancy for nonrigid registration was much larger at 1.9 Degree-Sign , 2.4 Degree-Sign , and 4.5 Degree-Sign and 10.1, 11.9, and 6.9 mm at 90% confidence level. Conclusions: The 3D surface imaging system is capable of detecting rigid setup errors with good accuracy for head-and-neck cancer. Further investigations are needed to improve the accuracy in detecting nonrigid setup errors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Contouring and Constraining Bowel on a Full-Bladder Computed Tomography Scan May Not Reflect Treatment Bowel Position and Dose Certainty in Gynecologic External Beam Radiation Therapy

Purpose: To evaluate, in a gynecologic cancer setting, changes in bowel position, dose-volume parameters, and biological indices that arise between full-bladder (FB) and empty-bladder (EB) treatment situations; and to evaluate, using cone beam computed tomography (CT), the validity of FB treatment presumption. Methods and Materials: Seventeen gynecologic cancer patients were retrospectively analyzed. Empty-bladder and FB CTs were obtained. Full-bladder CTs were used for planning and dose optimization. Patients were given FB instructions for treatment. For the study purpose, bowel was contoured on the EB CTs for all patients. Bowel position and volume changes between FB and EB states were determined. Full-bladder plans were applied on EB CTs for determining bowel dose-volume changes in EB state. Biological indices (generalized equivalent uniform dose and normal tissue complication probability) were calculated and compared between FB and EB. Weekly cone beam CT data were available in 6 patients to assess bladder volume at treatment. Results: Average (±SD) planned bladder volume was 299.7 ± 68.5 cm{sup 3}. Median bowel shift in the craniocaudal direction between FB and EB was 12.5 mm (range, 3-30 mm), and corresponding increase in exposed bowel volume was 151.3 cm{sup 3} (range, 74.3-251.4 cm{sup 3}). Absolute bowel volumes receiving 45 Gy were higher for EB compared with FB (mean 328.0 ± 174.8 vs 176.0 ± 87.5 cm{sup 3}; P=.0038). Bowel normal tissue complication probability increased 1.5× to 23.5× when FB planned treatments were applied in the EB state. For the study, the mean percentage value of relative bladder volume at treatment was 32%. Conclusions: Full-bladder planning does not necessarily translate into FB treatments, with a patient tendency toward EB. Given the uncertainty in daily control over bladder volume for treatment, we strongly recommend a “planning-at-risk volume bowel” (PRV{sub B}owel) concept to account for bowel motion between FB and EB that can be tailored for the individual patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗