Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Flow Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

PLTTER user's guide

The PLTTER graphics system, which is part of CDDMS is discussed. CDDMS is a comprehensive system for data basing and subsequent plotting of data acquired during wind tunnel tests or from computational flow analyses. The PLTTER is a system which creates report-quality plots of data which is stored on a CDDMS data base. The Requests file system allows plot-controlling information to be arranged in the way which is most appropriate for any application. The PLTTER system features many capabilities which are especially useful when plotting wind tunnel data. The PLTTER offers a variety of page formats, different grid options and parametric curve fitting algorithms, and a powerful legend capability to identify relevant information about individual curves. One or more plots on a page can be suppressed if desired so that an established page format can be maintained. Final plot output may be standard Versatec plots, QMS Laser printer plots, or microfiche.

Barlow, A.↗

The multidriver: A reliable multicast service using the Xpress Transfer Protocol

A reliable multicast facility extends traditional point-to-point virtual circuit reliability to one-to-many communication. Such services can provide more efficient use of network resources, a powerful distributed name binding capability, and reduced latency in multidestination message delivery. These benefits will be especially valuable in real-time environments where reliable multicast can enable new applications and increase the availability and the reliability of data and services. We present a unique multicast service that exploits features in the next-generation, real-time transfer layer protocol, the Xpress Transfer Protocol (XTP). In its reliable mode, the service offers error, flow, and rate-controlled multidestination delivery of arbitrary-sized messages, with provision for the coordination of reliable reverse channels. Performance measurements on a single-segment Proteon ProNET-4 4 Mbps 802.5 token ring with heterogeneous nodes are discussed.

Dempsey, Bert J.↗

An Exposure Prevention Plan for an Anhydrous Ammonia Handling System

In July of 1996, the Industrial Hygiene Team of the Environmental Management Office at NASA Lewis Research Center was contacted by the Space Station Program Office to conduct ammonia awareness training for a team of engineers and technicians. The team was tasked with assembling and operating an ammonia handling system for testing of a photovoltaic radiator at the NASA Plum Brook Station Space Power Facility. The ammonia handling system supports a radiator designed to radiate excess heat from a photovoltaic array module used to provide power to the International Space Station. The system would consist of a hazardous materials trailer equipped with an anhydrous ammonia tank, heater, accumulator, chiller, and flow bench. Meetings were held with representatives from the Space Station Program Office, the engineers and Plum Brook safety personnel. Guidance was also provided by representatives from Kennedy Space Center. Determinations were made concerning the locations and types of potential exposures and a plan was developed which included training, personal protective equipment, engineering controls and emergency response. Various organizations including the Plum Brook Safety Committee, the Lewis Environmental Management Office, the Test Readiness Review Board and the Program Office all had requirements that had to be met in order to satisfy themselves that all personnel involved in the operation of the system would be safe. What resulted was a comprehensive plan that provided more than adequate safety measures and succeeded in protecting all personnel from the hazards of the ammonia system. Testing of the photovoltaic radiator was successful and although ammonia leaks were detected and maintenance of the system was ongoing, no one was injured. It was felt that the training and controls in place allowed for a comfort level that did not interfere with the operations.

Cathy L Padolewski↗

System and method of making an enhanced cast iron crankshaft

A method and system for manufacturing a cast iron crankshaft for a vehicle are provided. The system comprises a molding unit arranged to form a negative sand cast mold of the cast iron crankshaft. The mold comprising at least one molded cavity having a pattern with dimensions of the cast iron crankshaft. The system further comprises a feeding mechanism comprising a riser having a connector through which molten metallic material flows to the cast mold. The feeding mechanism feeds the molten metallic material at a riser connection angle in the at least one mold cavity. The riser connection angle corresponds to a connector modulus. The connector modulus is 20% greater than a cast modulus. The riser geometry corresponds to a riser modulus. The riser modulus is 20% greater than the connector modulus. The system further comprises a furnace, a cooling area, a separation unit, a controller and a power source.

Wang, Liang↗

Selenium Speciation and Management in Wet FGD Systems

This report discusses results from bench- and pilot-scale simulation tests conducted to determine the factors that impact selenium speciation and phase partitioning in wet FGD systems. The selenium chemistry in wet FGD systems is highly complex and not completely understood, thus extrapolation and scale-up of these results may be uncertain. Control of operating parameters and application of scrubber additives have successfully demonstrated the avoidance or decrease of selenite oxidation at the bench and pilot scale. Ongoing efforts to improve sample handling methods for selenium speciation measurements are also discussed. Bench-scale scrubber tests explored the impacts of oxidation air rate, trace metals, scrubber additives, and natural limestone on selenium speciation in synthetic and field-generated full-scale FGD liquors. The presence and concentration of redox-active chemical species as well as the oxidation air rate contribute to the oxidation-reduction potential (ORP) conditions in FGD scrubbers. Selenite oxidation to the undesirable selenate form increases with increasing ORP conditions, and decreases with decreasing ORP conditions. Solid-phase manganese [Mn(IV)] appeared to be the significant metal impacting the oxidation of selenite to selenate. Scrubber additives were tested for their ability to inhibit selenite oxidation. Although dibasic acid and other scrubber additives showed promise in early clear liquor (sodium based and without calcium solids) bench-scale tests, these additives did not show strong inhibition of selenite oxidation in tests with higher manganese concentrations and with slurries from full-scale wet FGD systems. In bench-tests with field liquors, addition of ferric chloride at a 250:1 iron-to-selenium mass ratio sorbed all incoming selenite to the solid phase, although addition of ferric salts had no impact on native selenate that already existed in the field slurry liquor sample. As ORP increases, selenite may oxidize to selenate more rapidly than it sorbs to ferric solids. Though it was not possible to demonstrate a decrease in selenium concentrations to levels below the project's target of 50 μg/L during pilot testing, some trends observed in bench-scale testing were evident at the pilot scale. Specifically, reducing oxidation air rate and ORP tends to either retain selenium as selenite in the liquor or shift selenium phase partitioning to the solid phase. Oxidation air flow rate control may be one option for managing selenium behavior in FGD scrubbers. Units that cycle load widely may find it more difficult to impact ORP conditions with oxidation air flow rate control alone. Because decreasing oxidation air rates to the reaction tank showed that all new selenium reported to the solids, the addition of ferric chloride to the pilot scrubber could not show further improvements in selenium behavior. Ferric chloride addition did shift mercury to the slurry solids, specifically to the fine particles. Several competing pathways may govern the reporting of selenium to the slurry solids: co-precipitation with gypsum into the bulk solids and sorption or co-precipitation with iron into the fine particles. Simultaneous measurement of selenium and mercury behavior suggests a holistic management strategy is best to optimize the fate of both of these elements in FGD waters. Work conducted under this project evaluated sample handling and analytical methods for selenium speciation in FGD waters. Three analytical techniques and several preservation methods were employed. Measurements of selenium speciation over time indicated that for accurate selenium speciation, it is best to conduct measurements on unpreserved, filtered samples as soon after sampling as possible. The capital and operating costs for two selenium management strategies were considered: ferric chloride addition and oxidation air flow rate control. For ferric chloride addition, as might be expected the reagent makeup costs dominate the overall costs, and range from 0.22 to 0.29 mills/kWh. For oxidation air flow rate control, a cursory comparison of capital costs and turndown capabilities for multi-stage and single-stage centrifugal blowers and several flow control methods was completed. For greenfield systems, changing the selection of blower type and flow control method may have payback periods of 4 to 5 years or more if based on energy savings alone. However, the benefits to managing redox chemistry in the scrubber could far outweigh the savings in electricity costs under some circumstances.

20 FOSSIL-FUELED POWER PLANTS↗

Aerosol penetration of leak pathways : an examination of the available data and models.

Data and models of aerosol particle deposition in leak pathways are described. Pathways considered include capillaries, orifices, slots and cracks in concrete. The Morewitz-Vaughan criterion for aerosol plugging of leak pathways is shown to be applicable only to a limited range of particle settling velocities and Stokes numbers. More useful are sampling efficiency criteria defined by Davies and by Liu and Agarwal. Deposition of particles can be limited by bounce from surfaces defining leak pathways and by resuspension of particles deposited on these surfaces. A model of the probability of particle bounce is described. Resuspension of deposited particles can be triggered by changes in flow conditions, particle impact on deposits and by shock or vibration of the surfaces. This examination was performed as part of the review of the AP1000 Standard Combined License Technical Report, APP-GW-GLN-12, Revision 0, 'Offsite and Control Room Dose Changes' (TR-112) in support of the USNRC AP1000 Standard Combined License Pre-Application Review.

99 GENERAL AND MISCELLANEOUS↗

Predictive performance modeling framework for a novel enclosed particle receiver configuration and application for thermochemical energy storage

Concentrating solar power (CSP) plants can provide dispatchable power with a thermal energy storage capability for increased renewable-energy grid penetration. Particle-based CSP systems permit higher temperatures, and thus, potentially higher solar-to-electric efficiency than state-of-the-art molten-salt heat-transfer systems. This paper describes a detailed numerical analysis framework for estimating the performance of a novel, geometrically complex, enclosed particle receiver design. The receiver configuration uses arrays of small tubular absorbers to collect and subsequently transfer solar energy to a flowing particulate medium. The enclosed nature of the receiver design renders it amenable to either an inert heat-transfer medium, or a reactive heat-transfer medium that requires a controllable ambient environment. The numerical analysis framework described in this study is demonstrated for the case of thermal reduction of CaCr 0.1 Mn 0.9 O 3-$\delta$ for thermochemical energy storage. The modeling strategy consists of Monte Carlo ray tracing for absorbed solar-energy distributions from a surround heliostat field, computational fluid dynamics modeling of small-scale local tubular arrays, surrogate response surfaces that approximately capture simulated tubular array performance, a quasi-two-dimensional reduced-order description of counter-flow reactive solids and purge gas, and a radiative exchange model applied to embedded-cavity structures at the size scale of the full receiver. In this work we apply the numerical analysis strategy to a single receiver configuration, but the framework can be generically applicable to alternative enclosed designs. In conclusion, we assess sensitivity of receiver performance to surface optical properties, heat-transfer coefficients, solids outlet temperature, and purge-gas feed rates, and discuss the significance of model assumptions and results for future receiver development.

14 SOLAR ENERGY↗

Tailoring the response of Autonomous Reactivity Control (ARC) systems

The Autonomous Reactivity Control (ARC) system was developed to ensure inherent safety of Generation IV reactors while having a minimal impact on reactor performance and economic viability. In this study we present the transient response of fast reactor cores to postulated accident scenarios with and without ARC systems installed. Using a combination of analytical methods and numerical simulation, the principles of ARC system design that assure stability and avoids oscillatory behavior have been identified. A comprehensive transient analysis study for ARC-equipped cores, including a series of Unprotected Loss of Flow (ULOF) and Unprotected Loss of Heat Sink (ULOHS) simulations, were performed for Argonne National Laboratory (ANL) Advanced Burner Reactor (ABR) designs. With carefully designed ARC-systems installed in the fuel assemblies, the cores exhibit a smooth non-oscillatory transition to stabilization at acceptable temperatures following all postulated transients. To avoid oscillations in power and temperature, the reactivity introduced per degree of temperature change in the ARC system needs to be kept below a certain threshold the value of which is system dependent, the temperature span of actuation needs to be as large as possible.

ARC↗

High-bandwidth Modulation of H2/Syngas Fuel to Control Combustion Dynamics in Micro-Mixing Lean Premix Systems

The goal of this program was to develop and demonstrate fuel injection technologies that will facilitate the development of cost-effective turbine engines for Integrated Gasification Combined Cycle (IGCC) power plants, while improving efficiency and reducing emissions. The program involved developing a next-generation multi-point injector with enhanced stability performance for lean premix turbine systems that burn hydrogen (H2) or synthesis gas (syngas) fuels. A previously developed injector that demonstrated superior emissions performance was improved to enhance static flame stability through zone staging and pilot sheltering. In addition, piezo valve technology was implemented to investigate the potential for enhanced dynamic stability through high-bandwidth modulation of the fuel supply. Prototype injector and valve hardware were tested in an atmospheric combustion facility. The program was successful in meeting its objectives. Specifically, the following was accomplished: Demonstrated improvement of lean operability of the Parker multi-point injector through staging of fuel flow and primary zone sheltering; Developed a piezo valve capable of proportional and high-bandwidth modulation of gaseous fuel flow at frequencies as high as 500 Hz; The valve was shown to be capable of effecting changes to flame dynamics, heat release, and acoustic signature of an atmospheric combustor. The latter achievement indicates the viability of the Parker piezo valve technology for use in future adaptively controlled systems for the mitigation of combustion instabilities, particularly for attenuating combustion dynamics under ultra-lean conditions.

08 HYDROGEN↗

Off-design operation and performance of pumped thermal energy storage

In this article, we describe off-design models and control strategies for a Pumped Thermal Energy Storage (PTES) system that uses liquid thermal energy storage: specifically molten salt for hot storage and methanol for cold storage. Off-design conditions arise when load-following, or due to variations in storage tank temperatures or ambient temperatures. We propose a control strategy that uses inventory control to manage the mass flow rate in the thermodynamic cycles, which facilitates load following. We also propose a control strategy for the storage fluid mass flow rates, which are varied to ensure the molten salt is maintained at its design temperature. This maximizes efficiency and minimizes problems with salt freezing or degradation. The cold storage fluid mass flow rate is varied so that the cold tanks have the same state-of-charge as the hot tanks. This leads to variations in cold fluid temperature, but these variations are shown to be acceptably small (e.g. 7.5% increase), and this control method is shown to be simpler and more efficient than an alternative strategy where tanks become unbalanced. The ambient temperature and storage tank temperatures are moved ±50 °C from the design values and the impact on power, duration, and tank temperatures is quantified. Results demonstrate that the proposed control strategy is stable and self-correcting - that is, storage temperatures converge on stable values after two-to-three charge-discharge cycles. When inputs return to design values, the system returns to its design point after two charge-discharge cycles. We also demonstrate that inventory control enables delivery of the target power output even when off-design conditions exist that would normally reduce the power output.

25 ENERGY STORAGE↗

Parameter dependencies of the experimental nitrogen concentration required for detachment on ASDEX Upgrade and JET

While current tokamak experiments are beginning to use real-time feedback control systems to manage the plasma exhaust, future tokamaks still require validation of theoretical models used to predict the threshold impurity concentration required to sufficiently reduce the power and particle fluxes to the divertor. This work exploits new spectroscopic measurements of the divertor nitrogen concentration, c n , in partially detached N 2 -seeded H-mode plasmas on ASDEX Upgrade (AUG) and JET with the ITER-Like Wall (JET-ILW) to test the parameter dependencies of the power flowing to the outer divertor, P div,outer , and the separatrix electron density, n e.sep . A least-squares regression of the AUG measurements demonstrates that the threshold c n required for detachment scales as $c_n∝P^{1.19±0.32}_{div,outer}n^{-2.77±0.36}_{e,sep}$. This scaling of n e,sep is also consistent with the measurements from JET which, at constant P div,outer , show $c_n∝n^{-2.43±0.27}_{e,sep}$. The dependencies of P div,outer and n e.sep is demonstrated over at least a factor of two change in both parameters and indicates a stronger dependence on n e.sep in comparison to the Lengyel model, which could be due to the assumption in this model that the heat flux channel width is independent of density. This first assessment of detachment scaling with impurity seeding highlights the need for further analysis of the systematic uncertainties of the measurement and more consistent scenarios from more tokamaks to investigate the machine size scaling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integration of high confinement, high poloidal beta plasma with dual radiated power and detachment controls for divertor protection and ELM suppression

Divertor detachment without serious core confinement quality loss in DIII-D’s high poloidal β scenario has been combined with impurity-induced ELM mitigation without disruption. Use of Ne previously granted access to a detached, non-ELMing regime that retained high confinement quality due to stimulation of Internal Transport Barrier (ITB) growth, but suffered from on-going core fuel dilution and high disruptivity. Excess Ne accumulation in the core plasma has now been avoided by feeding back core radiated power ($P_{rad}$) measurements to control Ne seeding, rather than using attachment fraction ($A_{frac}$) control with Ne; this also reduces disruptivity. At the same time, N 2 seeding is used in a feedback loop with $A_{frac}$ measurements, which previously posed low disruption risk. In this way, the effect of Ne in the core is managed while avoiding excess seeding, and N 2 acts to correct for any excess heat exhaust that might interfere with detachment. The average Ne flow rate was 38% of what was used in pure Ne $A_{frac}$ control, plus average N 2 flow that was 43% of pure N 2 $A_{frac}$ control, even while meeting an even deeper detachment target. Meanwhile, a steep pressure gradient in the core plasma reduces sensitivity to impurity-induced degradation of the pedestal and reasonable confinement quality was maintained despite operational challenges that blocked formation of an ITB in these experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The ESRF Miniature Pulsed Magnetic Field System

We have developed a portable system to provide pulsed magnetic fields on the ESRF X-ray beamlines. The complete system consists of a power supply, liquid Helium and liquid Nitrogen dewars with a siphon each, control electronics and a double cryostat for separate coil and sample cooling. The liquid nitrogen cooled solenoids reach a maximum field of 30 Tesla for a total pulse duration of one milisecond. They are constructed for optimised cooling rate after the pulse to obtain a high duty cycle, the repetition rate is five pulses per minute at maximum field. The sample is cooled in an independent Helium flow cryostat which is inserted into the bore of the magnet. The flow cryostat has a temperature range from 5 to 250 Kelvin with a direct contact between the sample and Helium flow. This overview gives a general presentation of the system and we will show recent results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Numerical study on microwave-sustained argon discharge under atmospheric pressure

A numerical study on microwave sustained argon discharge under atmospheric pressure is reported in this paper. The purpose of this study is to investigate both the process and effects of the conditions of microwave-excited gas discharge under atmospheric pressure, thereby aiding improvements in the design of the discharge system, setting the appropriate working time, and controlling the operating conditions. A 3D model is presented, which includes the physical processes of electromagnetic wave propagation, electron transport, heavy species transport, gas flow, and heat transfer. The results can be obtained by means of the fluid approximation. The maxima of the electron density and gas temperature are 4.96 × 10{sup 18} m{sup −3} and 2514.8 K, respectively, and the gas pressure remains almost unchanged for typical operating conditions with a gas flow rate of 20 l/min, microwave power of 1000 W, and initial temperature of 473 K. In addition, the conditions (microwave power, gas flow rate, and initial temperature) of discharge are varied to obtain deeper information about the electron density and gas temperature. The results of our numerical study are valid and clearly describe both the physical process and effects of the conditions of microwave-excited argon discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Online Stochastic Optimization of Networked Distributed Energy Resources

Our work investigates distributed control and incentive mechanisms to coordinate distributed energy resources (DERs) with both continuous and discrete decision variables as well as device dynamics in distribution grids. We formulate a multi-period social welfare maximization problem, and based on its convex relaxation propose a distributed stochastic dual gradient algorithm for managing DERs. Moreover, we extend it to an online realtime setting with time-varying operating conditions, asynchronous updates by devices, and feedback being leveraged to account for nonlinear power flows as well as reduce communication overhead. The resulting algorithm provides a general online stochastic optimization algorithm for coordinating networked DERs with discrete power setpoints and dynamics to meet operational and economic objectives and constraints. We characterize the convergence of the algorithm analytically and evaluate its performance numerically.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Certification and User Manual for A 5kW Heat Exchanger Test Loop at Low Temperatures and High-Pressures

Yankee Scientific has designed and built a custom heat exchanger test stand (HXTS), for Oak Ridge National Laboratory, to support a program to develop advanced heat exchangers (HX) for geothermal Organic Rankine Cycle (ORC) power plants under Subcontract Number 40000141544 with ORNL. The test stand was designed to measure the performance of laboratory scale sub-sections of these advanced heat exchangers. Provisions have been made to facilitate testing the advanced heat exchanger as a primary refrigerant vaporizer and as a recuperator and as the system condenser. The test loop was operated with a controller and was instrumented with 11 thermocouples, 5 pressure gauges, 2 pressure transducers, 2 differential pressure transducers, and 3 flow meters.

15 GEOTHERMAL ENERGY↗

Output of acoustical sources

Acoustic radiation from a source, here viewed as an immobile point singularity with periodic strength and a given multipolar nature, is affected by the presence of nearly structural elements (e.g., rigid or impedance surfaces) as well as that of a background flow in the medium. An alternative to the conventional manner of calculating the net source output by integrating the energy flux over a distant control surface is described; this involves a direct evaluation of the secondary wavefunction at the position of the primary source and obviates the need for a (prospectively difficult) flux integration. Various full and half-planar surface configurations with an adjacent source are analyzed in detail, and the explicit results obtained, in particular, for the power factor of a dipole brings out a substantial rise in its output as the source nears the sharp edge of a half-plane.

Levine, H.↗

Variable Frequency Diverter Actuation for Flow Control

The design and development of an actively controlled fluidic actuator for flow control applications is explored. The basic device, with one input and two output channels, takes advantage of the Coanda effect to force a fluid jet to adhere to one of two axi-symmetric surfaces. The resultant flow is bi-stable, producing a constant flow from one output channel, until a disturbance force applied at the control point causes the flow to switch to the alternate output channel. By properly applying active control the output flows can be manipulated to provide a high degree of modulation over a wide and variable range of frequency and duty cycle. In this study the momentary operative force is applied by small, high speed isolation valves of which several different types are examined. The active fluidic diverter actuator is shown to work in several configurations including that in which the operator valves are referenced to atmosphere as well as to a source common with the power stream.

Culley, Dennis E.↗