Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Stability analysis of spacecraft power systems

The problems in applying standard electric utility models, analyses, and algorithms to the study of the stability of spacecraft power conditioning and distribution systems are discussed. Both single-phase and three-phase systems are considered. Of particular concern are the load and generator models that are used in terrestrial power system studies, as well as the standard assumptions of load and topological balance that lead to the use of the positive sequence network. The standard assumptions regarding relative speeds of subsystem dynamic responses that are made in the classical transient stability algorithm, which forms the backbone of utility-based studies, are examined. The applicability of these assumptions to a spacecraft power system stability study is discussed in detail. In addition to the classical indirect method, the applicability of Liapunov's direct methods to the stability determination of spacecraft power systems is discussed. It is pointed out that while the proposed method uses a solution process similar to the classical algorithm, the models used for the sources, loads, and networks are, in general, more accurate. Some preliminary results are given for a linear-graph, state-variable-based modeling approach to the study of the stability of space-based power distribution networks.

Halpin, S. M.↗

Fuel Cell Backup Power System for Grid Service and Microgrid in Telecommunication Applications

This paper presents the feasibility and economics of using fuel cell backup power systems in telecommunication cell towers to provide grid services (e.g., ancillary services, demand response (DR)) as well as power for cell towers during emergency conditions. This study evaluates the strategic integration of clean, efficient, and reliable fuel cell systems with the grid for improved economic benefits. The backup systems can potentially enhance capabilities through information exchange with the power grid, which adds value for grid services that depend on location and time. The economic analysis focused on the potential revenue for distributed telecommunications fuel cell backup units to provide value-added power supply. This paper includes case studies on current fuel cell backup power locations and regional grid service programs. The grid service benefits and system configurations for different operation modes provide opportunities for expanding backup fuel cell applications responsive to grid needs. The objective of this work is primarily on how fuel cells can become a significant part of the telecom backup power fleet to reduce system costs, environmental impact, and dependence on fossil fuels, while ensuring continuity of indispensable service for mobile users. The study identifies different fuel cell applications and nano/microgrid approaches for an extensive network of fuel cells as distributed energy resources. The possibilities of various application scenarios extend to fuel cell technologies and microgrids for reliable power supply.

30 DIRECT ENERGY CONVERSION↗

Advances in solid state switchgear technology for large space power systems

High voltage solid state remote power controllers (RPC's) and the required semiconductor power switches to provide baseline technology for large, high power distribution systems in the space station, all electric airplane and other advanced aerospace applications were developed. The RPC's were developed for dc voltages from 28 to 1200 V and ac voltages of 115, 230, and 440 V at frequencies of 400 Hz to 20 kHz. The benefits and operation of solid state RPC's and highlights of several developments to bring the RPC to technology readiness for future aerospace needs are examined. The 28 V dc Space Shuttle units, three RPC types at 120 V dc, two at 270/300 V dc, two at 230 V ac and several high power RPC models at voltages up to 1200 V dc with current ratings up to 100 A are reviewed. New technology programs to develop a new family of (DI)2 semiconductor switches and 20 kHz, 440 V ac RPC's are described.

Sundberg, G. R.↗

Advanced in solid state switchgear technology for large space power systems

High voltage solid state remote power controllers (RPC's) and the required semiconductor power switches to provide baseline technology for large, high power distribution systems in the Space Station, all electric airplane and other advanced aerospace applications were developed. The RPC's were developed for dc voltages from 28 to 1200 V and ac voltages of 115, 230, and 440 V at frequencies of 400 Hz to 20 kHz. The benefits and operation of solid state RPC's and highlights of several developments to bring the RPC to technology readiness for future aerospace needs are examined. The 28 V dc Space Shuttle units, three RPC types at 120 V dc, two at 270/300 V dc, two at 230 V ac and several high power RPC models at voltages up to 1200 V dc with current ratings up to 100 A are reviewed. New technology programs to develop a new family of (DI)2 semiconductor switches and 20 kHz, 440 V ac RPC's are described.

Sundberg, G. R.↗

Physics-Informed Sparse Gaussian Process for Probabilistic Stability Analysis of Large-Scale Power System with Dynamic PVs and Loads

This work proposes a physics-informed sparse Gaussian process (SGP) for probabilistic stability assessment of large-scale power systems in the presence of uncertain dynamic PVs and loads. The differential and algebraic equations considering uncertainties from dynamic PVs and loads are reformulated to a nonlinear mapping relationship that allows the application of SGP. Thanks to the nonparametric characteristic of Gaussian process, the proposed framework does not require distributions of uncertain inputs and this distinguishes it from existing approaches. As the original Gaussian process is not scalable to large-scale systems with high dimensional uncertain inputs, this paper develops the SGP with a stochastic variational inference technique. It leads to approximately two orders of complex reduction. A data pre-processing step is also introduced to tackle the coexistence of stable and unstable cases by sample clustering and constructing separate SGPs. The probabilistic transient stability index is analyzed to assess system stability under different uncertain dynamics loads and PVs. Comparisons are performed with the sampling-based, the polynomial chaos expansion-based, and traditional Gaussian process-based methods on the modified IEEE 118-bus and Texas 2000-bus systems under various scenarios, including different levels of uncertainties and the existence of nonlinear correlations among dynamic PVs. The impacts of data quality and quantity issues are also investigated. It is shown that the proposed SGP achieves significantly improved computational efficiency while maintaining high accuracy with a limited number of data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Implementation of a virtual link between power system testbeds at Marshall Spaceflight Center and Lewis Research Center

The Marshall Space Flight Center (MSFC) owns and operates a space station module power management and distribution (SSM-PMAD) testbed. This system, managed by expert systems, is used to analyze and develop power system automation techniques for Space Station Freedom. The Lewis Research Center (LeRC), Cleveland, Ohio, has developed and implemented a space station electrical power system (EPS) testbed. This system and its power management controller are representative of the overall Space Station Freedom power system. A virtual link is being implemented between the testbeds at MSFC and LeRC. This link would enable configuration of SSM-PMAD as a load center for the EPS testbed at LeRC. This connection will add to the versatility of both systems, and provide an environment of enhanced realism for operation of both testbeds.

Doreswamy, Rajiv↗

Design of small Stirling dynamic isotope power system for robotic space missions

Design of a multihundred-watt Dynamic Isotope Power System (DIPS) based on the U.S. Department of Energy (DOE) General Purpose Heat Source (GPHS) and small (multihundred-watt) free-piston Stirling engine (FPSE) technology is being pursued as a potential lower cost alternative to radioisotope thermoelectric generators (RTG's). The design is targeted at the power needs of future unmanned deep space and planetary surface exploration missions ranging from scientific probes to Space Exploration Initiative precursor missions. Power level for these missions is less than a kilowatt. Unlike previous DIPS designs which were based on turbomachinery conversion (e.g. Brayton), this small Stirling DIPS can be advantageously scaled down to multihundred-watt unit size while preserving size and mass competitiveness with RTG's. Preliminary characterization of units in the output power ranges 200-600 We indicate that on an electrical watt basis the GPHS/small Stirling DIPS will be roughly equivalent to an advanced RTG in size and mass but require less than a third of the isotope inventory.

Bents, D. J.↗

Improving Transient Stability of Interconnected Power Systems Through HVDE Controls

AC-DC corridors have been extensively used for bulk power transmission. In many of the cases, the power transfer through the parallel A C lines is restricted due to stability limits. Fast active power modulations of the HVDC link could enhance transient stability of interconnected power systems. This could be achieved by effectively utilizing the available headroom of the HVDC link, especially the transient overloading capability of classic HVDC link. In this paper, control schemes for HVDC power modulations are discussed. The effectiveness of HVDC link power modulations is demonstrated through the improved transient stability of the Pacific A C and DC Interties of North America under critical disturbances. System studies are performed using the detailed dynamic model of the Western Interconnection system.

Sundaresh, Lakshmi↗

Impedance-Based Characterization of Power System Frequency Response: Preprint

This paper presents an impedance-based noninvasive approach for the characterization of power system frequency response in real time in the absence of a transient event. It measures transfer function response from the injected active power to the frequency at the point of interconnection for the estimation of inertia and primary frequency response of the system. The so-called frequency response function also shows the effects of the speed of primary frequency control. The paper also derives the relationship between the frequency response function and the network impedance seen from the point of interconnection. This relationship highlights how impedance captures the frequency response behavior of a network. The proposed methodology is demonstrated on a modified IEEE 9-bus system with 25% penetration of wind and PV generation; a 5-MW battery energy storage system is used for the injection of active power perturbations for the measurement of the frequency response function.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessment of the technology required to develop photovoltaic power system for large scale national energy applications

A technical assessment of a program to develop photovoltaic power system technology for large-scale national energy applications was made by analyzing and judging the alternative candidate photovoltaic systems and development tasks. A program plan was constructed based on achieving the 10 year objective of a program to establish the practicability of large-scale terrestrial power installations using photovoltaic conversion arrays costing less than $0.50/peak W. Guidelines for the tasks of a 5 year program were derived from a set of 5 year objectives deduced from the 10 year objective. This report indicates the need for an early emphasis on the development of the single-crystal Si photovoltaic system for commercial utilization; a production goal of 5 x 10 to the 8th power peak W/year of $0.50 cells was projected for the year 1985. The developments of other photovoltaic conversion systems were assigned to longer range development roles. The status of the technology developments and the applicability of solar arrays in particular power installations, ranging from houses to central power plants, was scheduled to be verified in a series of demonstration projects. The budget recommended for the first 5 year phase of the program is $268.5M.

Lutwack, R.↗

Space Power Facility Readiness for Space Station Power System Testing

This document provides information which shows that the NASA Lewis Research Center's Space Power Facility (SPF) will be ready to execute the Space Station electric power system thermal vacuum chamber testing. The SPF is located at LeRC West (formerly the Plum Brook Station), Sandusky, Ohio. The SPF is the largest space environmental chamber in the world, having an inside horizontal diameter of 100 ft. and an inside height at the top of the hemisphere of 122 ft. The vacuum system can achieve a pressure lower than 1 x 10(exp -5) Torr. The cryoshroud, cooled by gaseous nitrogen, can reach a temperature of -250 F, and is 80 ft. long x 40 ft. wide x 22 ft. high. There is access to the chamber through two 50 ft. x 50 ft. doors. Each door opens into an assembly area about 150 ft. long x 70 ft. wide x 80 ft. high. Other available facilities are offices, shop area, data acquisition system with 930 pairs of hard lines, 7 megawatts of power to chamber, 245K gal. liquid nitrogen storage, cooling tower, natural gas, service air, and cranes up to 25 tons.

Smith, Roger L.↗

Solar thermal power system

A solar thermal power generator includes an inclined elongated boiler tube positioned in the focus of a solar concentrator for generating steam from water. The boiler tube is connected at one end to receive water from a pressure vessel as well as connected at an opposite end to return steam back to the vessel in a fluidic circuit arrangement that stores energy in the form of heated water in the pressure vessel. An expander, condenser, and reservoir are also connected in series to respectively produce work using the steam passed either directly (above a water line in the vessel) or indirectly (below a water line in the vessel) through the pressure vessel, condense the expanded steam, and collect the condensed water. The reservoir also supplies the collected water back to the pressure vessel at the end of a diurnal cycle when the vessel is sufficiently depressurized, so that the system is reset to repeat the cycle the following day. The circuital arrangement of the boiler tube and the pressure vessel operates to dampen flow instabilities in the boiler tube, damp out the effects of solar transients, and provide thermal energy storage which enables time shifting of power generation to better align with the higher demand for energy during peak energy usage periods.

14 SOLAR ENERGY↗

Ensuring Solution Uniqueness in Three-Phase Power System State Estimation

This paper is concerned with the issue of potential non-unique solutions in three-phase state estimation. Theory of observability analysis for positive sequence power system state estimation is based on certain assumptions that avoid possibility of multiple solutions. Also, it is shown that observability of a positive sequence network remains independent of the network parameters or the operating state. When extending single-phase observability analysis directly to the three-phase case, this paper considers the possibility of converging to multiple solutions, i.e. solution non-uniqueness, even for cases where state estimator successfully converges. The study illustrates via numerical examples the likelihood of converging to entirely different solutions for certain network parameters. It also examines how the operating state, particularly under unbalanced loading, leads to solution non-uniqueness. The paper then describes an alternative approach to ensure a unique solution in three-phase state estimation. This method aims to accurately and uniquely estimate the state of any unbalanced three-phase system, irrespective of load imbalance, network configuration, existence of synchronous generators or transformers.

Power System State Estimation, Three-Phase, Distri↗

Demonstration of a Variable Phase Turbine Power System for Low Temperature Geothermal Resources

A variable phase turbine assembly will be designed and manufactured having a turbine, operable with transcritical, two-phase or vapor flow, and a generator – on the same shaft supported by process lubricated bearings. The assembly will be hermetically sealed and the generator cooled by the refrigerant. A compact plate-fin heat exchanger or tube and shell heat exchanger will be used to transfer heat from the geothermal fluid to the refrigerant. The demonstration turbine will be operated separately with two-phase flow and with vapor flow to demonstrate performance and applicability to the entire range of low temperature geothermal resources. The vapor leaving the turbine is condensed in a plate-fin refrigerant condenser. The heat exchanger, variable phase turbine assembly and condenser are all mounted on single skids to enable factory assembly and checkout and minimize installation costs. The system will be demonstrated using low temperature (237F) well flow from an existing large geothermal field. The net power generated, 1 megawatt, will be fed into the existing power system at the demonstration site. The system will demonstrate reliable generation of inexpensive power from low temperature resources. The system will be designed for mass manufacturing and factory assembly and should cost less than $\$$1,200/kWe installed, when manufactured in large quantities. The estimated cost of power for 300F resources is predicted to be less than 5 cents/kWh. This should enable a substantial increase in power generated from low temperature geothermal resources.

15 GEOTHERMAL ENERGY↗

Virtual Critical Coupling in High-Power Resonant Systems

Power reflections are a fundamental challenge in high-power resonant systems, causing energy loss, limiting per- formance, and potentially damaging critical components. This problem is particularly acute in applications such as lower hybrid current drive (LHCD) for tokamak-based nuclear fusion, where efficient, stable power transfer to the plasma is paramount. In this work, we introduce and experimentally demonstrate the virtual critical coupling (VCC) mechanism, a nonmechanical method to achieve reflection-free excitation in high-power S-band resonators. VCC utilizes a temporally shaped excitation signal with a precise complex frequency, tailored to the resonator’s characteristics to enable complete energy absorption. Using a custom low-level RF system and a 5-MW S-band klystron, we conducted experiments from low power (32 mW) to high power (600 kW). Furthermore, the results demonstrate a greater than ninefold reduction in the reflection coefficient compared to conventional monochromatic excitation. This signal processing-based approach offers a robust path toward enhancing the efficiency and stability of high-power resonant systems, with significant implications for particle accelerators and the advancement of nuclear fusion energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Harmonics of 60 Hz in power systems caused by geomagnetic disturbances

Simultaneous VLF/ULF observations carried out near Winnipeg, Manitoba show that geomagnetic disturbances control the behavior of harmonics of 60 Hz man-made electric power. The harmonics of 60 Hz detected by the VLF receiver are at multiples of 180 Hz, indicating that they originated from a 3 phase ac power system. Under geomagnetically quiet conditions, only odd harmonics of 70 Hz were detected. In disturbed conditions, both odd and even harmonics were excited. The strength of each harmonic changed concurrently with geomagnetic pulsation (ULF) activity. These findings seem to indicate that a portion of telluric currents shunted into the power line system through the neutrals of the Y-connected transformers give rise to a dc bias to the transformer core materials and that it distorts their hysteresis loops, activating harmonics of 60 Hz power. A mathematical proof is given that a hysteresis loop having a point of symmetry generates odd harmonics only, whereas loops lacking in point-symmetry generally give rise to both odd and even harmonics. A general formula was obtained to calculate the strength of each harmonic based on the shape of the hysteresis loop.

Hayashi, K.↗

Applying Reduced Generator Models in the Coarse Solver of Parareal in Time Parallel Power System Simulation

The development of high-performance computing techniques and platforms has provided many opportunities for real-time or even faster-than-real-time implementation of power system simulations. One approach uses the Parareal in time framework. The Parareal algorithm has shown promising theoretical simulation speedups by temporal decomposing a simulation run into a coarse simulation on the entire simulation interval and fine simulations on sequential sub-intervals linked through the coarse simulation. However, it has been found that the time cost of the coarse solver needs to be reduced to fully exploit the potentials of the Parareal algorithm. This paper studies a Parareal implementation using reduced generator models for the coarse solver and reports the testing results on the IEEE 39-bus system and a 327-generator 2383-bus Polish system model.

High-performance computing↗