Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Imaging Primary Mouse Sarcomas After Radiation Therapy Using Cathepsin-Activatable Fluorescent Imaging Agents

Purpose: Cathepsin-activated fluorescent probes can detect tumors in mice and in canine patients. We previously showed that these probes can detect microscopic residual sarcoma in the tumor bed of mice during gross total resection. Many patients with soft tissue sarcoma (STS) and other tumors undergo radiation therapy (RT) before surgery. This study assesses the effect of RT on the ability of cathepsin-activated probes to differentiate between normal and cancerous tissue. Methods and Materials: A genetically engineered mouse model of STS was used to generate primary hind limb sarcomas that were treated with hypofractionated RT. Mice were injected intravenously with cathepsin-activated fluorescent probes, and various tissues, including the tumor, were imaged using a hand-held imaging device. Resected tumor and normal muscle samples were harvested to assess cathepsin expression by Western blot. Uptake of activated probe was analyzed by flow cytometry and confocal microscopy. Parallel in vitro studies using mouse sarcoma cells were performed. Results: RT of primary STS in mice and mouse sarcoma cell lines caused no change in probe activation or cathepsin protease expression. Increasing radiation dose resulted in an upward trend in probe activation. Flow cytometry and immunofluorescence showed that a substantial proportion of probe-labeled cells were CD11b-positive tumor-associated immune cells. Conclusions: In this primary murine model of STS, RT did not affect the ability of cathepsin-activated probes to differentiate between tumor and normal muscle. Cathepsin-activated probes labeled tumor cells and tumor-associated macrophages. Our results suggest that it would be feasible to include patients who have received preoperative RT in clinical studies evaluating cathepsin-activated imaging probes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advancing Performance Assessment for Disposal of Depleted Uranium at Clive Utah - 12493

A Performance Assessment (PA) for disposal of depleted uranium (DU) waste has recently been completed for a potential disposal facility at Clive in northwestern Utah. For the purposes of this PA, 'DU waste' includes uranium oxides of all naturally-occurring isotopes, though depleted in U-235, varying quantities of other radionuclides introduced to the uranium enrichment process in the form of used nuclear reactor fuel (reactor returns), and decay products of all of these radionuclides. The PA will be used by the State of Utah to inform an approval decision for disposal of DU waste at the facility, and will be available to federal regulators as they revisit rulemaking for the disposal of DU. The specific performance objectives of the Clive DU PA relate to annual individual radiation dose within a 10,000-year performance period, groundwater concentrations of specific radionuclides within a 500-year compliance period, and site stability in the longer term. Fate and transport processes that underlie the PA model include radioactive decay and ingrowth, diffusion in gaseous and water phases, water advection in unsaturated and saturated zones, transport caused by plant and animal activity, cover naturalization, natural and anthropogenic erosion, and air dispersion. Fate and transport models were used to support the dose assessment and the evaluation of groundwater concentrations. Exposure assessment was based on site-specific scenarios, since the traditional human exposure scenarios suggested by DOE and NRC guidance are unrealistic for this site. Because the U-238 in DU waste reaches peak radioactivity (secular equilibrium) after 2 million years (My) following its separation, the PA must also evaluate the impact of climate change cycles, including the return of pluvial lakes such as Lake Bonneville. The first draft of the PA has been submitted to the State of Utah for review. The results of this preliminary analysis indicate that doses are very low for the site-specific receptors for the 10,000-year compliance period. This is primarily because DU waste is not highly radioactive within this time frame, the DU waste is assumed to be buried beneath zones exposed by erosion, groundwater concentrations of DU waste constituents do not exceed groundwater protection limits with in the 500-year compliance period, and the first deep lake occurrence will disperse DU waste across a large area, and will ultimately be covered by lake-derived sediment. A probabilistic PA model was constructed that considered DU waste and decay product doses to site-specific receptors for a 10,000-yr performance period, as well as deep-time effects. The quantitative results are summarized in Table VII. Doses (as TEDE) are always less than 5 mSv in a year, and doses to the offsite receptors are always much less than 0.25 mSv in a year. Groundwater concentrations of Tc-99 are always less than its GWPL except when the Tc-99 contaminated waste is disposed below grade. Even in this case, the median groundwater concentration is only 4.18 Bq/L (113 pCi/L), which is more than one order of magnitude less than the GWPL for Tc-99. The results overall suggest that there are disposal configurations that can be used to dispose of the proposed quantities of DU waste that are adequately protective of human health. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Neoadjuvant Chemoradiation for Distal Rectal Cancer: 5-Year Updated Results of a Randomized Phase 2 Study of Neoadjuvant Combined Modality Chemoradiation for Distal Rectal Cancer

Purpose: To assess the efficacy of 2 different approaches to neoadjuvant chemoradiation for distal rectal cancers. Methods and Materials: One hundred six patients with T3/T4 distal rectal cancers were randomized in a phase 2 study. Patients received either continuous venous infusion (CVI) of 5-Fluorouracil (5-FU), 225 mg/m{sup 2} per day, 7 days per week plus pelvic hyperfractionated radiation (HRT), 45.6 Gy at 1.2 Gy twice daily plus a boost of 9.6 to 14.4 Gy for T3 or T4 cancers (Arm 1), or CVI of 5-FU, 225 mg/m{sup 2} per day, Monday to Friday, plus irinotecan, 50 mg/m{sup 2} once weekly × 4, plus pelvic radiation therapy (RT), 45 Gy at 1.8 Gy per day and a boost of 5.4 Gy for T3 and 9 Gy for T4 cancers (Arm 2). Surgery was performed 4 to 10 weeks later. Results: All eligible patients (n=103) are included in this analysis; 2 ineligible patients were excluded, and 1 patient withdrew consent. Ninety-eight of 103 patients (95%) underwent resection. Four patients did not undergo surgery for either disease progression or patient refusal, and 1 patient died during induction chemotherapy. The median time of follow-up was 6.4 years in Arm 1 and 7.0 years in Arm 2. The pathological complete response (pCR) rates were 30% in Arm 1 and 26% in Arm 2. Locoregional recurrence rates were 16% in Arm 1 and 17% in Arm 2. Five-year survival rates were 61% and 75% and Disease-specific survival rates were 78% and 85% for Arm1 and Arm 2, respectively. Five second primaries occurred in patients on Arm 1, and 1 second primary occurred in Arm 2. Conclusions: High rates of disease-specific survival were seen in each arm. Overall survival appears affected by the development of unrelated second cancers. The high pCR rates with 5-FU and higher dose radiation in T4 cancers provide opportunity for increased R0 resections and improved survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-655: Quantifying the Dosimetric Characteristics of a Calypso Compatible Radiotherapy Treatment Couch with Angular Transmission Functions

Purpose: To quantified the dosimetric characteristics of a Calypso compatible radiotherapy couch using continuously scanned transmission factor as a function of gantry angle. Methods: Radiation dose as a function of gantry angle was measured with an ionization chamber at the center of a 30 cm diameter cylindrical phantom placed on Qfix kVue Calypso compatible couch. A 3-D scanner was employed to continuously scan the dose during an arc rotation delivery. Nearly continuous transmission curves of 0.03° step size were obtained from IEC gantry angle 90° to180° for 6 MV and 15 MV photon beams at three couch longitudinal positions (due to longitudinally non-uniform shape of the couch rails) with rails both at the center and on sides. The transmission curves were evaluated to assess the attenuation by the couch. They were also compared to those of a carbon fiber couch top. Results: The scanned transmission curves of the Calypso comptible couch showed fine details of the couch transmission as a function of gantry angle. The attenuation by the couch varied from 2.4% to 12.9% for the 6 MV photo beam and from 1.8% to 8.9% for the 15 MV photon beam depending on the gantry angle. The attenuation by the flat couch top is only approximately 2 to 3%, but by the rail is much more significant. Because the rails are not uniformly shaped in the longitudinal direction, attenuation by the rail for the same gantry angle varied with the rail longitudinal position. The transmission curves of the carbon fiber couch top are nearly identical to those of the Calypso compatible couch top. Conclusion: The Calypso compatible couch attenuates radiation by 2.4%–12.9% and 1.8%–8.9% for 6 MV and 15 MV photon beams, respectively. The attenuation by the rails is much more significant than the flat couch top.

61 RADIATION PROTECTION AND DOSIMETRY↗

Do Angiotensin-Converting Enzyme Inhibitors Reduce the Risk of Symptomatic Radiation Pneumonitis in Patients With Non-Small Cell Lung Cancer After Definitive Radiation Therapy? Analysis of a Single-Institution Database

Purpose: Preclinical studies have suggested that angiotensin-converting enzyme inhibitors (ACEIs) can mitigate radiation-induced lung injury. We sought here to investigate possible associations between ACEI use and the risk of symptomatic radiation pneumonitis (RP) among patients undergoing radiation therapy (RT) for non–small cell lung cancer (NSCLC). Methods and Materials: We retrospectively identified patients who received definitive radiation therapy for stages I to III NSCLC between 2004 and 2010 at a single tertiary cancer center. Patients must have received a radiation dose of at least 60 Gy for a single primary lung tumor and have had imaging and dosimetric data available for analysis. RP was quantified according to Common Terminology Criteria for Adverse Events, version 3.0. A Cox proportional hazard model was used to assess potential associations between ACEI use and risk of symptomatic RP. Results: Of 413 patients analyzed, 65 were using ACEIs during RT. In univariate analysis, the rate of RP grade ≥2 seemed lower in ACEI users than in nonusers (34% vs 46%), but this apparent difference was not statistically significant (P=.06). In multivariate analysis of all patients, ACEI use was not associated with the risk of symptomatic RP (hazard ratio [HR] = 0.66; P=.07) after adjustment for sex, smoking status, mean lung dose (MLD), and concurrent carboplatin and paclitaxel chemotherapy. Subgroup analysis showed that ACEI use did have a protective effect from RP grade ≥2 among patients who received a low (≤20-Gy) MLD (P<.01) or were male (P=.04). Conclusions: A trend toward reduction in symptomatic RP among patients taking ACEIs during RT for NSCLC was not statistically significant on univariate or multivariate analyses, although certain subgroups may benefit from use (ie, male patients and those receiving low MLD). The evidence at this point is insufficient to establish whether the use of ACEIs does or does not reduce the risk of RP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determination of Internal Target Volume From a Single Positron Emission Tomography/Computed Tomography Scan in Lung Cancer

Purpose: The use of four-dimensional computed tomography (4D-CT) to determine the tumor internal target volume (ITV) is usually characterized by high patient radiation exposure. The objective of this study was to propose and evaluate an approach that relies on a single static positron emission tomography (PET)/CT scan to determine the ITV, thereby eliminating the need for 4D-CT and thus reduce patient radiation dose. Methods and Materials: The proposed approach is based on the concept that the observed PET image is the result of a joint convolution of an ideal PET image (free from motion and partial volume effect) with a motion-blurring kernel (MBK) and partial volume effect. In this regard, the MBK and tumor ITV are then estimated from the deconvolution of this joint model. To test this technique, phantom and patient studies were performed using different sphere/tumor sizes and motion trajectories. In all studies, a 4D-CT and a PET/CT image of the sphere/tumor were acquired. The ITV from the proposed technique was then compared to the maximum intensity projection (MIP) volume of the 4D-CT images. A Dice coefficient of the two volumes was calculated to represent the similarity between the two ITVs. Results: The average ITVs of the proposed technique were 97.2% {+-} 0.3% and 81.0% {+-} 16.7% similar to the MIP volume in the phantom and patient studies, respectively. The average dice coefficients were 0.87 {+-} 0.05 and 0.73 {+-} 0.16, respectively, for the two studies. Conclusion: Using the proposed approach, a single static PET/CT scan has the potential to replace a 4D-CT to determine the tumor ITV. This approach has the added advantage of reducing patient radiation exposure and determining the tumor MBK compared to 4D-CT/MIP-CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Eye tracking and gating system for proton therapy of orbital tumors

Purpose: A new motion-based gated proton therapy for the treatment of orbital tumors using real-time eye-tracking system was designed and evaluated. Methods: We developed our system by image-pattern matching, using a normalized cross-correlation technique with LabVIEW 8.6 and Vision Assistant 8.6 (National Instruments, Austin, TX). To measure the pixel spacing of an image consistently, four different calibration modes such as the point-detection, the edge-detection, the line-measurement, and the manual measurement mode were suggested and used. After these methods were applied to proton therapy, gating was performed, and radiation dose distributions were evaluated. Results: Moving phantom verification measurements resulted in errors of less than 0.1 mm for given ranges of translation. Dosimetric evaluation of the beam-gating system versus nongated treatment delivery with a moving phantom shows that while there was only 0.83 mm growth in lateral penumbra for gated radiotherapy, there was 4.95 mm growth in lateral penumbra in case of nongated exposure. The analysis from clinical results suggests that the average of eye movements depends distinctively on each patient by showing 0.44 mm, 0.45 mm, and 0.86 mm for three patients, respectively. Conclusions: The developed automatic eye-tracking based beam-gating system enabled us to perform high-precision proton radiotherapy of orbital tumors.

60 APPLIED LIFE SCIENCES↗

High sensitivity phase retrieval method in grating-based x-ray phase contrast imaging

Purpose: Grating-based x-ray phase contrast imaging is considered as one of the most promising techniques for future medical imaging. Many different methods have been developed to retrieve phase signal, among which the phase stepping (PS) method is widely used. However, further practical implementations are hindered, due to its complex scanning mode and high radiation dose. In contrast, the reverse projection (RP) method is a novel fast and low dose extraction approach. In this contribution, the authors present a quantitative analysis of the noise properties of the refraction signals retrieved by the two methods and compare their sensitivities. Methods: Using the error propagation formula, the authors analyze theoretically the signal-to-noise ratios (SNRs) of the refraction images retrieved by the two methods. Then, the sensitivities of the two extraction methods are compared under an identical exposure dose. Numerical experiments are performed to validate the theoretical results and provide some quantitative insight. Results: The SNRs of the two methods are both dependent on the system parameters, but in different ways. Comparison between their sensitivities reveals that for the refraction signal, the RP method possesses a higher sensitivity, especially in the case of high visibility and/or at the edge of the object. Conclusions: Compared with the PS method, the RP method has a superior sensitivity and provides refraction images with a higher SNR. Therefore, one can obtain highly sensitive refraction images in grating-based phase contrast imaging. This is very important for future preclinical and clinical implementations.

60 APPLIED LIFE SCIENCES↗

Interval to Biochemical Failure Highly Prognostic for Distant Metastasis and Prostate Cancer-Specific Mortality After Radiotherapy

Purpose: Few biochemical parameters have been related to mortality. The present study examined the clinical utility of the interval to biochemical failure (IBF) as a prognostic factor for distant metastasis (DM) and prostate cancer-specific mortality (PCSM) after radiotherapy. Methods and Materials: The study group consisted of 211 T1c-T3Nx-N0M0 patients who had experienced BF among 1,174 men treated with three-dimensional conformal radiotherapy alone. Biochemical failure was defined as a post-treatment prostate-specific antigen (PSA) level of at, or greater than, the PSA nadir plus 2 ng/mL. Cox proportional hazards modeling was used to identify independent predictors of DM and PCSM on multivariate analysis. Results: An IBF of <18 months was independently predictive for DM (p = 0.008), as was a Gleason score of 7-10 (p = 0.0005), PSA nadir {>=}2 ng/mL (p = 0.04), and decreasing radiation dose (p = 0.02) on multivariate analysis, including increasing pretreatment PSA level, PSA nadir {>=}2.5 ng/mL, PSA doubling time of <3 months, and Stage T3 disease. An IBF of <18 months was the only predictor of PCSM (p = 0.0003) in the same model. The actuarial 5-year DM rate for an IBF of <18 vs. {>=}18 months was 52% vs. 20% (p < 0.0001), and the actuarial PCSM rate was 36% vs. 6%, respectively (p = 0.0001). Conclusions: The IBF is an important descriptor of the PSA kinetics after radiotherapy to identify men at high risk of clinical failure and death. A IBF of <18 months could aid in selecting men for early, aggressive salvage therapy or participation in a clinical trial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transfemoral Venous Access Facilitates Upper Extremity Dialysis Interventions: Procedural Success and Clinical Outcomes

Purpose: To report technical success and clinical outcomes of transfemoral venous access for upper extremity dialysis interventions. Materials and Methods: A total of 15 patients underwent a transfemoral venous approach for fistulography (n = 4; 27%) or thrombectomy (n = 11; 73%) over a 14-month period. Access characteristics, sheath size, thrombectomy method, angioplasty site, fluoroscopy time, radiation dose, technical and clinical success, complications, and post-intervention primary and secondary patency rates were recorded. Results: Access type included arteriovenous fistulas (n = 10; 67%) and grafts (n = 5; 33%). The most common configuration was brachio-brachial (n = 6; 38%). Mean age of access was 37 months. Mean prior interventions were 4. Right CFV access was used in all patients using 6–8-French (most common: 7-French [n = 10; 67%]) sheaths. Most thrombectomies (n = 11; 73%) required both pharmacologic and mechanical maceration (n = 9; 82%). All accesses required angioplasty to treat underlying stenosis at the outflow vein (n = 12; 80%) or arteriovenous anastomosis (n = 9; 90%). Mean fluoroscopy time was 26.43 min. Air kerma and dose area product were 178.06 ± 225.77 mGy and 57,768.83 ± 87,553.29 μGym{sup 2}, respectively. Procedural and clinical success rates were 93% and 80%, respectively. Technical failure was due to persistent stenosis in one patient. Clinical failure was due to unsuccessful dialysis immediately following intervention in three patients. Mean post-intervention primary patency and secondary patency durations were 2.8 and 4.8 months, respectively. Primary patency rates at 1 and 3 months were 50% and 35%, respectively. Secondary patency rates at 1 and 3 months were 58% and 30%, respectively. Conclusion: A transfemoral venous approach for intervention of upper extremity dialysis accesses may be a valuable adjunct to traditional approaches.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase 2 Study of Concurrent Cetuximab Plus Definitive Thoracic Radiation Therapy Followed by Consolidation Docetaxel Plus Cetuximab in Poor Prognosis or Elderly Patients With Locally Advanced Non-Small Cell Lung Cancer

Background: Recursive partitioning analysis has shown that Eastern Cooperative Oncology Group (ECOG) Performance Status (PS) ≥2, male sex, and age ≥70 years are prognostic of poor outcome in locally advanced non-small cell lung cancer (LA-NSCLC) patients. Concurrent chemoradiation therapy (CRT) improves survival, but toxicity is a concern in this frail patient cohort. We therefore opened this trial of concurrent definitive thoracic radiation therapy (XRT) and cetuximab, followed by consolidation docetaxel plus cetuximab. Methods and Materials: Eligible patients had pathologically proven, unresectable LA-NSCLC (stage IIA-“dry” IIIB). They had ECOG PS 2 or weight loss ≥5% in 3 months or were aged ≥70 years. The primary objective was progression-free survival (PFS). Secondary objectives included overall survival (OS) and overall response rate (ORR). Results: From May 2008 to November 2010, a total of 32 patients were evaluated in our single-institution, institutional review board–approved prospective clinical trial. Three patients were screen failures and 2 more withdrew consent before treatment, leaving 27 evaluable patients. One was removed because of poor therapy compliance, and 2 were taken off trial because of grade 3 cetuximab-related toxicities but were followed up under intent-to-treat analysis. The median follow-up and OS were 10.5 months. The median PFS was 7.5 months. The ORR was 59.3%. Eight early/sudden deaths were reported. Upon review, 6 patients developed severe pulmonary complications. Conclusions: Patients enrolled in this trial had improved OS compared with poor-PS historical controls (10.5 vs 6.4 months) and comparable OS to good-PS historical controls (10.5 vs 11.9 months) treated with XRT alone. However, pulmonary toxicity is a concern. Consolidative cetuximab/docetaxel, in conjunction with high-dose radiation therapy, is a putative cause.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Arms Down Cone Beam CT Hepatic Angiography Performance Assessment: Vascular Imaging Quality and Imaging Artifacts

IntroductionThe practice of positioning patients’ arms above the head during catheter-injected hepatic arterial phase cone beam CT (A-CBCT) imaging has been inherited from standard CT imaging due to image quality concerns, but interrupts workflow and extends procedure time. We sought to assess A-CBCT image quality and artifacts with arms extended above the head versus down by the side.MethodsWe performed an IRB approved retrospective evaluation of reformatted and 3D-volume rendered images from 91 consecutive A-CBCTs (43 arms up, 48 arms down) acquired during hepatic tumor arterial embolization procedures. Two interventional radiologists reviewed all A-CBCT imaging and assigned vessel visualization scores (VVS) from 1 to 5, ranging from non-diagnostic to optimal visualization. Streak artifacts across axial images were rated from 1 to 3 based on resulting image quality (none to significant). Presence of respiratory or cardiac motion during acquisition, body mass index and radiation dose area product (DAP) were also recorded and analyzed. Univariate and multivariate analyses were used to assess the impact of arm position on VVS and imaging artifacts.ResultsVVS were not significantly associated with arm position during A-CBCT imaging. One reader reported more streak artifacts across axial images in the arms down group (p = 0.005). DAP was not statistically different between the groups (23.9 Gy cm{sup 2} [6.1–73.4] arms up, 26.1 Gy cm{sup 2} [4.2–102.6] arms down, p = 0.54).ConclusionA-CBCT angiography performed with the arms above the head is not superior for clinically relevant hepatic vascular visualization compared to imaging performed with the arms by the patient’s side.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Processes for Quality Improvements in Radiation Oncology Clinical Trials

Quality assurance in radiotherapy (RT) has been an integral aspect of cooperative group clinical trials since 1970. In early clinical trials, data acquisition was nonuniform and inconsistent and computational models for radiation dose calculation varied significantly. Process improvements developed for data acquisition, credentialing, and data management have provided the necessary infrastructure for uniform data. With continued improvement in the technology and delivery of RT, evaluation processes for target definition, RT planning, and execution undergo constant review. As we move to multimodality image-based definitions of target volumes for protocols, future clinical trials will require near real-time image analysis and feedback to field investigators. The ability of quality assurance centers to meet these real-time challenges with robust electronic interaction platforms for imaging acquisition, review, archiving, and quantitative review of volumetric RT plans will be the primary challenge for future successful clinical trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Incidence, Natural History, and Patterns of Locoregional Recurrence in Gastric Cancer Patients Treated With Preoperative Chemoradiotherapy

Purpose: To retrospectively determine the incidence and patterns (in-field, marginal, or out-of-field) of locoregional gastric cancer recurrence in patients who received preoperative chemoradiotherapy and to determine the outcome in these patients. Methods and Materials: Between 1994 and 2004, 149 patients with gastric carcinoma were treated according to institutional protocols with preoperative chemoradiotherapy. Ultimately, 105 patients had an R0 resection. Of these 105 patients, 65 received preoperative chemotherapy followed by chemoradiotherapy and 40 received preoperative chemoradiotherapy. Most (96%) of these patients received 5-fluorouracil-based chemotherapy during radiotherapy, and the median radiation dose was 45 Gy. We retrospectively identified and classified the patterns of locoregional recurrence. Results: The 3-year actuarial incidence of locoregional recurrence was 13%, with locoregional disease recurring as any part of the failure pattern in 14 patients. Most (64%) of the evaluable locoregional recurrences were in-field. Of the 4 patients with a marginal recurrence, 2 had had inadequate coverage of the regional nodal volumes on their oblique fields. The pathologic complete response rate was 23%. A pathologic complete response was the only statistically significant predictor of locoregional control. Conclusion: Patients with gastric cancer who received preoperative chemoradiotherapy had low rates of locoregional recurrence. This strategy merits prospective multi-institutional and randomized evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The impact of including spatially longitudinal heterogeneities of vessel oxygen content and vascular fraction in 3D tumor oxygenation models on predicted radiation sensitivity

Purpose: Oxygen distribution models have been used to analyze the influences of oxygen tensions on tissue response after radiotherapy. These distributions are often generated assuming constant oxygen tension in the blood vessels. However, as red blood cells progress through the vessels, oxygen is continuously released into the plasma and the surrounding tissue, resulting in longitudinally varying oxygen levels in the blood vessels. In the present study, the authors investigated whether a tumor oxygenation model that incorporated longitudinally varying oxygen levels would provide different predictions of necrotic fractions and radiosensitivity compared to commonly used models with a constant oxygen pressure. Methods: Our models simulated oxygen diffusion based on a Green's function approach and oxygen consumption according to the Michaelis-Menten equation. The authors constructed tumor models with different vascular fractions (VFs), from which they generated depth oxygenation curves and a look-up table of oxygen pressure gradients. The authors evaluated models of spherical tumors of various sizes, from 1 to 10{sup 4} mg. The authors compared the results from a model with constant vessel oxygen (CVO) pressure to those from models with longitudinal variations in oxygen saturation and either a constant VF (CVF) or variable VF (VVF) within the tumor tissue. The authors monitored the necrotic fractions, defined as tumor regions with an oxygen pressure below 1 mmHg. Tumor radiation sensitivity was expressed as D{sub 99,} the homogeneous radiation dose required for a tumor control probability of 0.99. Results: In the CVO saturation model, no necrosis was observed, and decreasing the VF could only decrease the D{sub 99} by up to 10%. Furthermore, the D{sub 99} vs VF dependence was similar for different tumor masses. Compared to the CVO model, the extended CVF and VVF models provided clearly different results, including pronounced effects of VF and tumor size on the necrotic fraction and D{sub 99}, necrotic fractions ranging from 0% to 97%, and a maximal D{sub 99} increment of 57%. Only minor differences were observed between different vessel architectures, i.e., CVF vs VVF. In the smallest tumor with a low necrotic fraction, the D{sub 99} strictly decreased with increasing blood velocity. Increasing blood velocity also decreased the necrotic fraction in all tumor sizes. VF had the most profound influence on both the necrotic fraction and on D{sub 99}. Conclusions: Our present analysis of necrotic formation and the impact of tumor oxygenation on D{sub 99} demonstrated the importance of including longitudinal variations in vessel oxygen content in tumor models. For small tumors, radiosensitivity was particularly dependent on VF and slightly dependent on the blood velocity and vessel arrangement. These dependences decreased with increasing tumor size, because the necrotic fraction also increased, thereby decreasing the number of viable tumor cells that required sterilization. The authors anticipate that the present model will be useful for estimating tumor oxygenation and radiation response in future detailed studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-245: Is Off-Line Adaptive Radiotherapy Sufficient for Head and Neck Cancer with IGRT?

Purpose: Radiation doses delivered to patients with head and neck cancer (HN) may deviate from the planned doses because of variations in patient setup and anatomy. This study was to evaluate whether off-line Adaptive Radiotherapy (ART) is sufficient. Methods: Ten HN patients, who received IMRT under daily imaging guidance using CT-on-rail/KV-CBCT, were randomly selected for this study. For each patient, the daily treatment setup was corrected with translational only directions. Sixty weekly verification CTs were retrospectively analyzed. On these weekly verification CTs, the tumor volumes and OAR contours were manually delineated by a physician. With the treatment iso-center placed on the verification CTs, according to the recorded clinical shifts, the treatment beams from the original IMRT plans were then applied to these CTs to calculate the delivered doses. The electron density of the planning CTs and weekly CTs were overridden to 1 g/cm3. Results: Among 60 fractions, D99 of the CTVs in 4 fractions decreased more than 5% of the planned doses. The maximum dose of the spinal cord exceeded 10% of the planned values in 2 fractions. A close examination indicated that the dose discrepancy in these 6 fractions was due to patient rotations, especially shoulder rotations. After registering these 6 CTs with the planning CT allowing six degree of freedoms, the maximum rotations around 3 axes were > 1.5° for these fractions. With rotation setup errors removed, 4 out of 10 patients still required off-line ART to accommodate anatomical changes. Conclusion: A significant shoulder rotations were observed in 10% fractions, requiring patient re-setup. Off-line ART alone is not sufficient to correct for random variations of patient position, although ART is effective to adapt to patients' gradual anatomic changes. Re-setup or on-line ART may be considered for patients with large deviations detected early by daily IGRT images. The study is supported in part by Siemens Medical Solutions.

60 APPLIED LIFE SCIENCES↗

Establishing an IEZ at the K-25 Site With Realism [Slides]

The requirement from ANSI/ANS-8.3 states: (1) a criticality alarm system meeting the requirements of this standard shall be installed in areas where personnel would be subject to an excessive radiation dose; and (2) excessive dose = any dose to personnel corresponding to an absorbed dose from neutrons and gamma rays equal to or greater than 0.12 Gy (12 rad) in free air. The requirement was misconstrued to imply that the Immediate Evaluation Zone (IEZ) had to cover out to 12 Rad of dose. This misinterpretation prompted the following official clarification: The standard does not attempt to define the area that is to be evacuated, which is considered a management responsibility and outside the scope of this Standard. What we wanted was an IEZ that: (1) depended on the facility characteristics and hazards; (2) departed from the one 'Size' fits all mentality; (3) balanced the risk of a criticality with the risk of evacuating; and (4) was consistent with the emergency planning process. What they have is a facility that is a mile long; a facility that was falling down around them; a facility where workers are routinely in fall protection; and a facility where high noise is the normal condition. They ended up matching ANS-8.23 with their EPHA and DSA and eliminated 12 Rad as the criterion; integrated Emergency Planning into the process; established evacuation zones using DSA consequence levels; and introduced time dependence into the evacuation process.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Resected Pancreatic Neuroendocrine Tumors: Patterns of Failure and Disease-Related Outcomes With or Without Radiotherapy

Purpose: Pancreatic neuroendocrine tumors (NET) are rare and have better disease-related outcomes compared with pancreatic adenocarcinoma. Surgical resection remains the standard of care, although many patients present with locally advanced or metastatic disease. Little is known regarding the use of radiotherapy in the prevention of local recurrence after resection. To better define the role of radiotherapy, we performed an analysis of resected patients at our institution. Methods: Between 1994 and 2009, 33 patients with NET of the pancreatic head and neck underwent treatment with curative intent at Duke University Medical Center. Sixteen patients were treated with surgical resection alone while an additional 17 underwent resection with adjuvant or neoadjuvant radiation therapy, usually with concurrent fluoropyrimidine-based chemotherapy (CMT). Median radiation dose was 50.4 Gy and median follow-up 28 months. Results: Thirteen patients (39%) experienced treatment failure. Eleven of the initial failures were distant, one was local only and one was local and distant. Two-year overall survival was 77% for all patients. Two-year local control for all patients was 87%: 85% for the CMT group and 90% for the surgery alone group (p = 0.38). Two-year distant metastasis-free survival was 56% for all patients: 46% and 69% for the CMT and surgery patients, respectively (p = 0.10). Conclusions: The primary mode of failure is distant which often results in mortality, with local failure occurring much less commonly. The role of radiotherapy in the adjuvant management of NET remains unclear.

62 RADIOLOGY AND NUCLEAR MEDICINE↗