Four-dimensional multi-level stimulated rotational Ramanscattering dynamics in air
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
We describe a device and method that uses elevated electron emission rates to identify surface defects in fine wires. The device is a gas-tight cylinder with fine wires strung across it. The wire to be tested is positioned on the axis of the device. Eighteen field forming and six sensor wires surround the wire to be tested. Special algorithms control the wire voltages to independently vary the surface electric field of the test wire, while keeping the sensor wire's gains consistent. Good surface-quality wires show a constant electron emission rate as a function of the surface electric field strength up to values of ~80 kV/cm (depending on wire radius) while bad-quality wire shows the emergence of high emission rates at significantly lower electric fields.
Abstract not provided.
For presentation at the Geologic Society of America Annual Meeting, Pittsburgh, PA, October 15-18, 2023.
The dismantling of the former German fuel reprocessing research center Wiederaufbeitungsanlage Karlsruhe requires extensive investigations of contamination and dose rate inside of the shielded areas. Particularly for first the exploration of radiation field existing thermo-element pipes may offer access to the tanks and to other interesting points without the risk of contamination. Because of their small dimension, almost no active dosimetry systems are able to measure inside the pipes. New mm-scale luminescence dosimeters in combination with a packing and transport technique are presented. The dosimeters could measure doses from 0.1 mGy up to more than 100 Gy. Hence, over the possible exposure time durations, dose rates from μGyh{sup -1} up to 1000 Gyh{sup -1} are ascertainable. For potential users the system opens the opportunity for investigation of dose rates inside of shielding and in contaminated environments. Particularly in constricted environments the technique is a unique solution for dose and dose rate measurement tasks. Within the linear dose range up to several ten Gy, the uncertainty of the results is less than 5%. 100 Gy-doses can be specified within 20%, with individual high dose calibration of the detectors even better. For WAK and other potential users the system offers the opportunity to investigate dose rates inside of shieldings and in contaminated environments. Particularly in constricted environments the technique is an unique solution for dose and dose rate measurements. (authors)
Explore the source record for details and available documents.
Explore the source record for details and available documents.
core and drilling data, hydraulic fracturing
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Attosecond x-ray pulses are an indispensable tool for the study of electronic and structural changes in molecules undergoing chemical reactions. They have a wide bandwidth comparable to the energy bands of valence electronic states and, therefore, are well suited for making and probing multiple valence electronic excitations using core electron transitions. Here we propose a method of creating a sequence of two attosecond soft x-ray pulses in a free electron laser by optical manipulation of electrons located in two different sections of the electron bunch. The energy of each x-ray pulse can be of the order of 100 nJ and the pulse width of the order of 250 attoseconds. The carrier frequency of each x-ray pulse can be independently tuned to a resonant core electron transition of a specific atom of the molecule. The time interval between the two attosecond pulses is tunable from a few femtoseconds to a hundred femtoseconds with better than 100 attoseconds precision.
A laboratory study of cryogenic fracturing was performed to test its ability to improve oil/gas recovery from low-permeability reservoirs. Our aim is to develop well-stimulation technologies using cryogenic fluids [e.g., liquid nitrogen (LN)] to increase permeability in a large reservoir volume surrounding wells. The new technology has the potential to reduce formation damage caused by current stimulation methods and minimize or eliminate water usage. The concept of cryogenic fracturing is that a sharp thermal gradient (thermal shock) created at the surfaces of formation rocks by applying cryogenic fluid can cause strong local tensile stress and start fractures. We created a laboratory system for cryogenic fracturing under true-triaxial loading, with LN-delivery/control and -measurement systems. The loading system simulates confining stresses by independently loading each axis up to approximately 5,000 psi on 888-in. cubes. Temperature in boreholes and at block surfaces and fluid pressure in boreholes were continuously monitored. Acoustic and pressure-decay measurements were obtained before and at various stages of stimulations. Cubic blocks (8 88-in.) of Niobrara shale, concrete, and sandstones were tested, and stress levels and anisotropies varied. Three schemes were considered: Gas fracturing without cryo-stimulation, gas fracturing after low-pressure cryogen flow-through, and gas fracturing after high-pressure cryogen flow-through. Findings from pressure-decay tests show that LN stimulation clearly increases permeability, and repeated stimulations further increase the permeability. Acoustic velocities and amplitudes decreased significantly after cryo-stimulation, indicating fracture creation. In the gas fracturing without the stimulation, breakdown (complete fracturing) occurs suddenly without any initial leaking, and major fracture planes form along the plane containing principal-stress and intermediate-stress directions, as expected theoretically. However, in the gas fracturing after cryogenic stimulations, breakdown occurred gradually and with massive leaking because of thermal fractures created during stimulation. In addition, the major fracture direction does not necessarily follow the plane containing the principal-stress direction, especially at low confining-stress levels. In tests, we observed that cryogenic stimulation seems to disrupt the internal stress field. The increase in borehole temperature after stimulation affects the permeability of the specimen. When a stimulated specimen is still cold, it maintains high permeability because fractures remain open and local thermal tension is maintained near the borehole. When the rock warms back, fractures close and permeability decreases. In these tests, we have not used proppants. Overall, fractures are clearly generated by low- and high-pressure thermal shocks. The added pressure of the high-pressure thermal shocks helps to further propagate cryogenic fractures generated by thermal shock. Breakdown pressure is significantly lowered by LN stimulation, with observed breakdown-pressure reductions up to approximately 40%.
Purpose: Clinically, there exists a need to develop a non-invasive technique for monitoring salivary activity. In this study, we investigate the feasibility of a using the electrical conductivity information from Electrical Impedance Tomography (EIT) to monitor salivary flow activity. Methods: To acquire EIT data, eight Ag/AgCl ECG electrodes were placed around the mandible of the subject. An EIT scan was obtained by injecting current at 50 KHz, 0.4 mA through each pair of electrodes and recording voltage across other electrode pairs. The functional conductivity image was obtained through reconstruction of the voltage data, using Electrical Impedance Tomography and Diffuse Optical Tomography Reconstruction Software (EIDORS) in Matlab. In using EIDORS, forward solution was obtained using a user-defined finite element model shape and inverse solution was obtained using one-step Gaussian solver. EIT scans of volunteer research team members were acquired for three different physiological states: pre-stimulation, stimulation and post-stimulation. For pre-stimulation phase, data were collected in intervals of 5 minutes for 15 minutes. The salivary glands were then stimulated in the subject using lemon and the data were collected immediately. Post-stimulation data were collected at 4 different timings after stimulation. Results: Variations were observed in the electrical conductivity patterns near parotid regions between the pre- and post-stimulation stages. The three images acquired during the 15 minute pre-stimulation phase showed no major changes in the conductivity. Immediately after stimulation, electrical conductivity increased near parotid regions and 15 minutes later slowly returned to pre-stimulation level. Conclusion: In the present study involving human subjects, the change in electrical conductivity pattern shown in the EIT images, acquired at different times with and without stimulation of salivary glands, appeared to be consistent with the change in salivary gland activity. The conductivity changes imaged through EIT are potentially useful for the purpose of salivary monitoring.
Abstract This paper outlines a data collection and diagnostics case study involving multiple horizontal shale wells. We look at well production profiles using rate transient analysis, differences in near wellbore complexity, geologic variations within the area of interest, as well as compositional differences in the rocks based on cores obtained from within the stimulated reservoir. The Hydraulic Fracturing Test Site is a multi-well experiment involving stimulation of unconventional shale wells in the southeastern Midland portion of the Permian Basin. The targeted formations include both the upper as well as the middle Wolfcamp formations, also referred alternatively as Wolfcamp A and Wolfcamp B. Data integration and analysis shared in this paper help us understand the various geologic controls impacting well productivity, particularly the wide variance observed between the Wolfcamp A and Wolfcamp B formations. Rate transient analysis indicates similar system permeabilities for stimulated wells. However, we observe higher effective fracture half-lengths for upper Wolfcamp wells. Using observations from 3D seismic interpretations (such as pad scale faults) as well as petrophysical and image log data, we highlight the substantial differences in stimulation as we move along the well laterals from the heel toward the toe sections. These differences are further reconciled with observations from zones with high data density at the core locations through stimulated rock, as well as independent data such as microseismic emissions. At the test site, Wolfcamp A was found to be relatively quartz rich with significant heterogeneity whereas Wolfcamp B is richer in clay and organic content. This impacts the geomechanical characteristics of the rock mass with much higher natural fracture density in the shallower interval. Thus, the fracture growth is more uniform in the deeper interval and more heterogeneous with branching likely in upper interval. Increased complexity also leads to consistently better productivity from the wells in the shallower interval as demonstrated from RTA results. This case study is unique because it provides valuable insights from actual sampling of the stimulated zones in hydraulically fractured wells and helps understand impact of various factors that contribute toward variability in well production. The findings from this study provides insights into need for optimization of completion designs in the various Wolfcamp landing zones, such as optimization of cluster or fracture spacing in various Wolfcamp intervals. In addition, it provides a useful template for data collection and research direction in future field test sites of similar nature in unconventional reservoirs.
A coupled thermo-hydro-mechanical (THM) numerical workflow that is capable of modeling seismic slip is critical for the successful development of enhanced geothermal systems (EGS). By integrating key physical processes, this workflow enables accurate simulation of temperature and pressure diffusions, stress changes, and induced seismicity. As a result, it serves as a vital tool for predicting induced seismicity and optimizing reservoir stimulation strategies. The Utah FORGE (Frontier Observatory for Research in Geothermal Energy) project, located near Milford, Utah, is a U.S. Department of Energy initiative aimed at advancing EGS technology. In April 2024, eight new stimulation stages (Stages 3R-10) were conducted in well 16A (injection well) subsequent to the first series of stimulation (Stages 1-3) performed in April, 2022. To monitor the induced seismicity, geophones were deployed in wells 58-32, 56-32, and 78B-32, while fiber optic cables were also installed in wells 16B, 78-32, and 78B-32 to collect microseismic data and detect frac hits Preliminary analyses of microseismic catalogs and fiber optic data suggest that the stimulated fractures in Stages 3R–6 closely align with that generated during Stage 3, indicating that the new stimulations were likely reactivating the previously stimulated fracture. To better understand the underlying process, a comprehensive modeling approach that can accurately capture thermal, hydrological, mechanical, and seismic responses is essential. In this work, we propose and utilize a coupled thermo-hydro-mechanical and earthquake (THM+E) simulation workflow to numerically investigate the stimulation activities on well 16A. The specific objective is to confirm whether the new stimulation stages (Stages 3R–6) reactivated fractures previously stimulated during Stage 3. For this purpose, we perform THM+E simulations individually for Stages 3, 3R, 4, and 5, incorporating the discrete fracture networks (DFNs) created by the plane-fitting technique based on the microseismic catalogs. The simulation workflow consists of two separate models: a THM model and an earthquake model, coupled in a one-way manner. Detailed descriptions of the workflow are provided in Section 3. Simulation results are presented in terms of injection pressure, permeability evolution, and predicted seismic catalogs, which are then compared with field data for further analyses. This report is structured as follows. In Section 2, we present detailed analyses of the field data and propose the hypothesis that the new stimulation stages (Stages 3R–6) were probably reactivating the previously stimulated fractures in Stage 3. In Section 3, we introduce the coupled THM+E workflow and the problem setup to validate our hypothesis, followed by the simulation results for each stage in Section 4. Meanwhile, discussions are included to analyze the model predictions and their comparison with field data. Lastly, we conclude the report and outline future plans in Section 5.
Crewmember adapted to the microgravity state may need to egress the vehicle within a few minutes for safety and operational reasons after gravitational transitions. The transition from one sensorimotor state to another consists of two main mechanisms: strategic and plastic-adaptive and have been demonstrated in astronauts returning after long duration space flight. Strategic modifications represent "early adaptation" - immediate and transitory changes in control that are employed to deal with short-term changes in the environment. If these modifications are prolonged then plastic-adaptive changes are evoked that modify central nervous system function, automating new behavioral responses. More importantly, this longer term adaptive recovery mechanism was significantly associated with their strategic ability to recover on the first day after return to Earth G. We are developing a method based on stochastic resonance to enhance information transfer by improving the brain's ability to detect vestibular signals (Vestibular Stochastic Resonance, VSR) especially when combined with balance training exercises such as sensorimotor adaptability (SA) training for rapid improvement in functional skill, for standing and mobility. This countermeasure to improve detection of vestibular signals is a stimulus delivery system that is wearable/portable providing low imperceptible levels of white noise based binaural bipolar electrical stimulation of the vestibular system (stochastic vestibular stimulation). To determine efficacy of vestibular stimulation on physiological and perceptual responses during otolith-canal conflicts and dynamic perturbations we have conducted a series of studies: We have shown that imperceptible binaural bipolar electrical stimulation of the vestibular system across the mastoids enhances balance performance in the mediolateral (ML) plane while standing on an unstable surface. We have followed up on the previous study showing VSR stimulation improved balance performance in both ML and anteroposterior planes while stimulating in the ML axis only. We have shown the efficacy of VSR stimulations on enhancing physiological and perceptual responses of whole-body orientation during low frequency perturbations (0.1 Hz) on the ocular motor system using a variable radius centrifuge on both physiological (using eye movements) and perceptual responses (using a joystick) to track imposed oscillations. The variable radius centrifuge provides a selective tilting sensation that is detectable only by the otolith organs providing conflicting information from the canal organs of the vestibular system (intra-vestibular conflict). These results indicate that VSR can improve performance in sensory conflict scenarios like that experienced during space flight. We have showed the efficacy of VSR stimulation to improve balance and locomotor control on subjects exposed to continuous, sinusoidal lateral motion of the support surface while walking on a treadmill while viewing perceptually matched linear optic flow. We have shown the safety of short term continuous use of up to 4 hours of VSR stimulation and its efficacy in improving balance and locomotor function in Parkinson's Disease patients. This technique for improving vestibular signal detection may thus provide additional information to improve strategic abilities. We hypothesize that VSR stimulation will act synergistically with SA training to improve adaptability by increased utilization of vestibular information and therefore serve to optimize and personalize the SA countermeasure prescription. This forms the basis of its usefulness both as a training modality and further help in significantly reducing the number of days required to recover functional performance to preflight levels after long duration space flight.
Nickel is a potent hapten that induces contact hypersensitivity in human skin. While nickel induces the maturation of dendritic cells via NF-{kappa}B and p38 MAPK activation, it also exerts immunosuppressive effects on T cells through an unknown mechanism. To elucidate the molecular mechanisms of its effects on T cells, we examined the effects of NiCl{sub 2} on mRNA expression in human CD3+ T cells stimulated with CD3 and CD28 antibodies. Using a DNA microarray and Gene Ontology, we identified 70 up-regulated (including IL-1{beta}, IL-6 and IL-8) and 61 down-regulated (including IL-2, IL-4, IL-10 and IFN-{gamma}) immune responsive genes in NiCl{sub 2}-treated T cells. The DNA microarray results were verified using real-time PCR and a Bio-Plex{sup TM} suspension protein array. Suppression of IL-2 and IFN-{gamma} gene transcription by NiCl{sub 2} was also confirmed using Jurkat T cells transfected with IL-2 or IFN-{gamma} luciferase reporter genes. To explore the NiCl{sub 2}-regulated signaling pathway, we examined the binding activity of nuclear proteins to NFAT, AP-1, and NF-{kappa}B consensus sequences. NiCl{sub 2} significantly and dose-dependently suppressed NFAT- and AP-1-binding activity, but augmented NF-{kappa}B-binding activity. Moreover, NiCl{sub 2} decreased nuclear NFAT expression in stimulated T cells. Using Jurkat T cells stimulated with PMA/ionomycin, we demonstrated that NiCl{sub 2} significantly suppressed stimulation-evoked cytosolic Ca{sup 2+} increases, suggesting that NiCl{sub 2} regulates NFAT signals by acting as a blocker of Ca{sup 2+} release-activated Ca{sup 2+} (CRAC) channels. These data showed that NiCl{sub 2} decreases NFAT and increases NF-{kappa}B signaling in T cells. These results shed light on the effects of nickel on the molecular regulation of T cell signaling. - Graphical Abstract: Nickel suppresses stimulation-evoked cytosolic Ca{sup 2+} increase, which results in the suppression of NFAT signals. On the other hand, Ni rather stimulates NF-{kappa}B signaling. The effects of Nickel on these transcription factors modulate the expression of various immune related genes. Display Omitted Research Highlights: > Using DNA microarray and Gene Ontology, we identified 70 up-regulated and 61 down-regulated immune responsive genes in NiCl{sub 2}-treated T cells. > NiCl{sub 2} significantly suppressed the binding activity of nuclear proteins from stimulated T cells to NFAT and AP-1 consensus binding sites, while it rather augmented that from non-stimulated T cells to NF-{kappa}B. > NiCl{sub 2} significantly suppressed stimulation-evoked cytosolic Ca{sup 2+} increases, suggesting that NiCl{sub 2} regulates NFAT signals by acting as a blocker of CRAC channels.