Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spatial process”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

First application of liquid-metal-jet sources for small-animal imaging: High-resolution CT and phase-contrast tumor demarcation

Purpose: Small-animal studies require images with high spatial resolution and high contrast due to the small scale of the structures. X-ray imaging systems for small animals are often limited by the microfocus source. Here, the authors investigate the applicability of liquid-metal-jet x-ray sources for such high-resolution small-animal imaging, both in tomography based on absorption and in soft-tissue tumor imaging based on in-line phase contrast. Methods: The experimental arrangement consists of a liquid-metal-jet x-ray source, the small-animal object on a rotating stage, and an imaging detector. The source-to-object and object-to-detector distances are adjusted for the preferred contrast mechanism. Two different liquid-metal-jet sources are used, one circulating a Ga/In/Sn alloy and the other an In/Ga alloy for higher penetration through thick tissue. Both sources are operated at 40-50 W electron-beam power with {approx}7 {mu}m x-ray spots, providing high spatial resolution in absorption imaging and high spatial coherence for the phase-contrast imaging. Results: High-resolution absorption imaging is demonstrated on mice with CT, showing 50 {mu}m bone details in the reconstructed slices. High-resolution phase-contrast soft-tissue imaging shows clear demarcation of mm-sized tumors at much lower dose than is required in absorption. Conclusions: This is the first application of liquid-metal-jet x-ray sources for whole-body small-animal x-ray imaging. In absorption, the method allows high-resolution tomographic skeletal imaging with potential for significantly shorter exposure times due to the power scalability of liquid-metal-jet sources. In phase contrast, the authors use a simple in-line arrangement to show distinct tumor demarcation of few-mm-sized tumors. This is, to their knowledge, the first small-animal tumor visualization with a laboratory phase-contrast system.

60 APPLIED LIFE SCIENCES↗

Numerical Simulation and Model Analyses of In-situ Biogeochemical Remediation of Chromium at the LANL - 18306

Environmental management problems associated with contamination of groundwater resources with heavy metals (such as chromium) typically require complex biogeochemical model simulations and analysis of in situ remediation. Frequently, the in situ remediation is the only viable treatment option. In these cases, a three-dimensional reactive transport model of relevant biogeochemical processes is invaluable. Recently, we have developed a novel unique biogeochemical simulator called CHROTRAN (http://chrotran.lanl.gov; Hansen et al. 2017, Vesselinov et al. 2018a) capable to represent the full three-dimensional dynamics of processes associated with in situ biogeochemical remediation of heavy metals in heterogeneous aquifers. CHROTRAN accounts for spatial and temporal transients of (1) the heavy metal to be remediated, (2) introduced amendments (e.g., through well injection), and (3) biomass growth and decay. The introduced amendments can include (1) an electron donor (e.g., molasses), (2) a nontoxic-conservative bio-inhibitor (e.g., ethanol), and (3) a biocide (e.g., dithionite). In addition, direct abiotic reduction by donor-metal interaction as well as donor-driven biomass growth and bio-reduction are modeled in CHROTRAN. Other critical processes, such as donor sorption, bio-fouling and biomass death are also modeled. CHROTRAN can simulate the groundwater flow dynamics introduced due a series of injection and extraction wells and account for reduction of aquifer permeability near the wells due bio clogging. CHROTRAN is based on the existing PFLOTRAN (http://pflotran.org; Lichtner et al, 2017a) code framework, taking advantage of the reaction interface allowing for implementation of complex model features and leverage other facets of PFLOTRAN, such as multi-component geochemistry and high-performance computing. Here, we present numerical simulations and model analyses related to the Los Alamos National Laboratory (LANL) chromium site. The analyses are performed by coupling of CHROTRAN with MADS (Model Analysis and Decision Support; http://mads.lanl.gov; Vesselinov et al., 2018b). We present analyses related to uncertainty quantification of model predictions, sensitivity of model parameters and remedial decision support. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

LES ARM Symbiotic Simulation and Observation (LASSO) Implementation Strategy

This document illustrates the design of the Large-Eddy Simulation (LES) ARM Symbiotic Simulation and Observation (LASSO) workflow to provide a routine, high-resolution modeling capability to augment the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility’s high-density observations. LASSO will create a powerful new capability for furthering ARM’s mission to advance understanding of cloud, radiation, aerosol, and land-surface processes. The combined observational and modeling elements will enable a new level of scientific inquiry by connecting processes and context to observations and providing needed statistics for details that cannot be measured. The result will be improved process understanding that facilitates concomitant improvements in climate model parameterizations. The initial LASSO implementation will be for ARM’s Southern Great Plains site in Oklahoma and will focus on shallow convection, which is poorly simulated by climate models due in part to clouds’ typically small spatial scale compared to model grid spacing, and because the convection involves complicated interactions of microphysical and boundary layer processes.

Gustafson Jr., WI↗

Regional biogeography versus intra-annual dynamics of the root and soil microbiome

Abstract Background Root and soil microbial communities constitute the below-ground plant microbiome, are drivers of nutrient cycling, and affect plant productivity. However, our understanding of their spatiotemporal patterns is confounded by exogenous factors that covary spatially, such as changes in host plant species, climate, and edaphic factors. These spatiotemporal patterns likely differ across microbiome domains (bacteria and fungi) and niches (root vs. soil). Results To capture spatial patterns at a regional scale, we sampled the below-ground microbiome of switchgrass monocultures of five sites spanning > 3 degrees of latitude within the Great Lakes region. To capture temporal patterns, we sampled the below-ground microbiome across the growing season within a single site. We compared the strength of spatiotemporal factors to nitrogen addition determining the major drivers in our perennial cropping system. All microbial communities were most strongly structured by sampling site, though collection date also had strong effects; in contrast, nitrogen addition had little to no effect on communities. Though all microbial communities were found to have significant spatiotemporal patterns, sampling site and collection date better explained bacterial than fungal community structure, which appeared more defined by stochastic processes. Root communities, especially bacterial, were more temporally structured than soil communities which were more spatially structured, both across and within sampling sites. Finally, we characterized a core set of taxa in the switchgrass microbiome that persists across space and time. These core taxa represented < 6% of total species richness but > 27% of relative abundance, with potential nitrogen fixing bacteria and fungal mutualists dominating the root community and saprotrophs dominating the soil community. Conclusions Our results highlight the dynamic variability of plant microbiome composition and assembly across space and time, even within a single variety of a plant species. Root and soil fungal community compositions appeared spatiotemporally paired, while root and soil bacterial communities showed a temporal lag in compositional similarity suggesting active recruitment of soil bacteria into the root niche throughout the growing season. A better understanding of the drivers of these differential responses to space and time may improve our ability to predict microbial community structure and function under novel conditions.

59 BASIC BIOLOGICAL SCIENCES↗

A Framework of Hyperspectral Image Compression using Neural Networks

Hyperspectral image analysis has gained considerable attention due to its wide range of applications. Hyperspectral images provide a vast amount of information about underlying objects in an image by using a large range of the electromagnetic spectrum for each pixel. However, since the same image is taken multiple times using distinct electromagnetic bands, the size of such images tend to be significant, which leads to greater processing requirements. The aim of this paper is to present a proposed framework for image compression and to study the possible effects of spatial compression on quality of unmixing results. Image compression allows us to reduce the dimensionality of an image while still preserving most of the original information, which could lead to faster image processing. This paper presents preliminary results of different training techniques used in Artificial Neural Network (ANN) based compression algorithm.

97 MATHEMATICS AND COMPUTING↗

Generation of hybrid sinograms for the recovery of kV-CT images with metal artifacts for helical tomotherapy

Purpose: The overall goal of this study is to restore kilovoltage computed tomography (kV-CT) images which are disfigured by patients’ metal prostheses. By generating a hybrid sinogram that is a combination of kV and megavoltage (MV) projection data, the authors suggest a novel metal artifact-reduction (MAR) method that retains the image quality to match that of kV-CT and simultaneously restores the information of metal prostheses lost due to photon starvation. Methods: CT projection data contain information about attenuation coefficients and the total length of the attenuation. By normalizing raw kV projections with their own total lengths of attenuation, mean attenuation projections were obtained. In the same manner, mean density projections of MV-CT were obtained by the normalization of MV projections resulting from the forward projection of density-calibrated MV-CT images with the geometric parameters of the kV-CT device. To generate the hybrid sinogram, metal-affected signals of the kV sinogram were identified and replaced by the corresponding signals of the MV sinogram following a density calibration step with kV data. Filtered backprojection was implemented to reconstruct the hybrid CT image. To validate the authors’ approach, they simulated four different scenarios for three heads and one pelvis using metallic rod inserts within a cylindrical phantom. Five inserts describing human body elements were also included in the phantom. The authors compared the image qualities among the kV, MV, and hybrid CT images by measuring the contrast-to-noise ratio (CNR), the signal-to-noise ratio (SNR), the densities of all inserts, and the spatial resolution. In addition, the MAR performance was compared among three existing MAR methods and the authors’ hybrid method. Finally, for clinical trials, the authors produced hybrid images of three patients having dental metal prostheses to compare their MAR performances with those of the kV, MV, and three existing MAR methods. Results: The authors compared the image quality and MAR performance of the hybrid method with those of other imaging modalities and the three MAR methods, respectively. The total measured mean of the CNR (SNR) values for the nonmetal inserts was determined to be 14.3 (35.3), 15.3 (37.8), and 25.5 (64.3) for the kV, MV, and hybrid images, respectively, and the spatial resolutions of the hybrid images were similar to those of the kV images. The measured densities of the metal and nonmetal inserts in the hybrid images were in good agreement with their true densities, except in cases of extremely low densities, such as air and lung. Using the hybrid method, major streak artifacts were suitably removed and no secondary artifacts were introduced in the resultant image. In clinical trials, the authors verified that kV and MV projections were successfully combined and turned into the resultant hybrid image with high image contrast, accurate metal information, and few metal artifacts. The hybrid method also outperformed the three existing MAR methods with regard to metal information restoration and secondary artifact prevention. Conclusions: The authors have shown that the hybrid method can restore the overall image quality of kV-CT disfigured by severe metal artifacts and restore the information of metal prostheses lost due to photon starvation. The hybrid images may allow for the improved delineation of structures of interest and accurate dose calculations for radiation treatment planning for patients with metal prostheses.

60 APPLIED LIFE SCIENCES↗

Understanding Spatial and Spectral Morphologies of Ultracompact H II Regions

The spatial morphology, spectral characteristics, and time variability of ultracompact H II regions provide strong constraints on the process of massive star formation. We have performed simulations of the gravitational collapse of rotating molecular cloud cores, including treatments of the propagation of ionizing and non-ionizing radiation. We here present synthetic radio continuum observations of H II regions from our collapse simulations, to investigate how well they agree with observation, and what we can learn about how massive star formation proceeds. We find that intermittent shielding by dense filaments in the gravitationally unstable accretion flow around the massive star leads to highly variable H II regions that do not grow monotonically, but rather flicker, growing and shrinking repeatedly. This behavior appears able to resolve the well-known lifetime problem. We find that multiple ionizing sources generally form, resulting in groups of ultracompact H II regions, consistent with observations. We confirm that our model reproduces the qualitative H II region morphologies found in surveys, with generally consistent relative frequencies. We also find that simulated spectral energy distributions (SEDs) from our model are consistent with the range of observed H II region SEDs, including both regions showing a normal transition from optically thick to optically thin emission, and those with intermediate spectral slopes. In our models, anomalous slopes are solely produced by inhomogeneities in the H II region, with no contribution from dust emission at millimeter or submillimeter wavelengths. We conclude that many observed characteristics of ultracompact H II regions appear consistent with massive star formation in fast, gravitationally unstable, accretion flows.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of phosphorus in organisms at sub-micron resolution using X-ray fluorescence spectromicroscopy.

X-ray spectromicroscopy (combined X-ray spectroscopy and microscopy) is uniquely capable of determining sub-micron scale elemental content and chemical speciation in minimally-prepared particulate samples. The high spatial resolutions achievable with this technique have enabled the close examination of important microscale processes relevant to the cycling of biogeochemically important elements. Here, we demonstrate the value of X-ray microscopy to environmental and biological research by examining the phosphorus and metal chemistry of complete individual cells from the algal genera Chlamydomonas sp. and Chlorella sp. X-ray analysis revealed that both genera store substantial intracellular phosphorus as distinct, heterogeneously distributed granules whose X-ray fluorescence spectra are consistent with that of polyphosphate. Polyphosphate inclusions ranged in size from 0.3-1.4 {micro}m in diameter and exhibited a nonspecies-specific average phosphorus concentration of 6.87 {+-} 1.86 {micro}g cm{sup -2}, which was significantly higher than the average concentration of phosphorus measured in the total cell, at 3.14 {+-} 0.98 {micro}g cm{sup -2} (95% confidence). Polyphosphate was consistently associated with calcium and iron, exhibiting average P:cation molar ratios of 8.31 {+-} 2.00 and 108 {+-} 34, respectively (95% confidence). In some cells, polyphosphate was also associated with potassium, zinc, manganese, and titanium. Based on our results, X-ray spectromicroscopy can provide high-resolution elemental data on minimally prepared, unsectioned cells that are unattainable through alternative microscopic methods and conventional bulk chemical techniques currently available in many fields of marine chemistry.

58 GEOSCIENCES↗

Volume Imaging & Tracking Radar Open Research Topics

The Volume Imaging & Tracking Radar (VITR) is a multistatic broadband system designed to track multiple centimeter sized objects whose velocities exceed 1 km/s. The VITR characteristics are: Multistatic, multiple transmitters & receivers; Spatially diverse & aperiodic: The transmitting and receiving antennas may be arbitrarily located; Pulsed, broad band (6-13 GHz); Time-domain; One pulse in the air at a time; No carrier; Returns digitized, processed & analyzed at RF frequencies. The data products are: Three dimensional object of interest (OOI) tracks; Multistatic Doppler velocity estimates of the OOIs; Evolution of radar cross-section (RCS) as a function of time along the track; Volume movies (three spatial dimensions and time) of the OOIs; Bistatic inverse synthetic aperture radar (ISAR) processing.

42 ENGINEERING↗

Automated segmentation of cerebral vasculature with aneurysms in 3DRA and TOF-MRA using geodesic active regions: An evaluation study

Purpose: To evaluate the suitability of an improved version of an automatic segmentation method based on geodesic active regions (GAR) for segmenting cerebral vasculature with aneurysms from 3D x-ray reconstruction angiography (3DRA) and time of flight magnetic resonance angiography (TOF-MRA) images available in the clinical routine. Methods: Three aspects of the GAR method have been improved: execution time, robustness to variability in imaging protocols, and robustness to variability in image spatial resolutions. The improved GAR was retrospectively evaluated on images from patients containing intracranial aneurysms in the area of the Circle of Willis and imaged with two modalities: 3DRA and TOF-MRA. Images were obtained from two clinical centers, each using different imaging equipment. Evaluation included qualitative and quantitative analyses of the segmentation results on 20 images from 10 patients. The gold standard was built from 660 cross-sections (33 per image) of vessels and aneurysms, manually measured by interventional neuroradiologists. GAR has also been compared to an interactive segmentation method: isointensity surface extraction (ISE). In addition, since patients had been imaged with the two modalities, we performed an intermodality agreement analysis with respect to both the manual measurements and each of the two segmentation methods. Results: Both GAR and ISE differed from the gold standard within acceptable limits compared to the imaging resolution. GAR (ISE) had an average accuracy of 0.20 (0.24) mm for 3DRA and 0.27 (0.30) mm for TOF-MRA, and had a repeatability of 0.05 (0.20) mm. Compared to ISE, GAR had a lower qualitative error in the vessel region and a lower quantitative error in the aneurysm region. The repeatability of GAR was superior to manual measurements and ISE. The intermodality agreement was similar between GAR and the manual measurements. Conclusions: The improved GAR method outperformed ISE qualitatively as well as quantitatively and is suitable for segmenting 3DRA and TOF-MRA images from clinical routine.

60 APPLIED LIFE SCIENCES↗

Direct Observation of Spin-Torque Driven Magnetization Reversal Through Nonuniform Modes

We present time-resolved x-ray images with 30 nm spatial and 70 ps temporal resolution, which reveal details of the spatially resolved magnetization evolution in nanoscale samples of various dimensions during reversible spin-torque switching processes. Our data in conjunction with micromagnetic simulations suggest a simple unified picture of magnetic switching based on the motion of a magnetic vortex. With decreasing size of the magnetic element the path of the vortex core moves from inside to outside of the nanoelement, and the switching process evolves from a curled nonuniform to an increasingly uniform mode.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The segmented non-uniform dielectric module design for uniformity control of plasma profile in a capacitively coupled plasma chamber

Low-temperature plasma technique is one of the critical techniques in IC manufacturing process, such as etching and thin-film deposition, and the uniformity greatly impacts the process quality, so the design for the plasma uniformity control is very important but difficult. It is hard to finely and flexibly regulate the spatial distribution of the plasma in the chamber via controlling the discharge parameters or modifying the structure in zero-dimensional space, and it just can adjust the overall level of the process factors. In the view of this problem, a segmented non-uniform dielectric module design solution is proposed for the regulation of the plasma profile in a CCP chamber. The solution achieves refined and flexible regulation of the plasma profile in the radial direction via configuring the relative permittivity and the width of each segment. In order to solve this design problem, a novel simulation-based auto-design approach is proposed, which can automatically design the positional sequence with multi independent variables to make the output target profile in the parameterized simulation model approximate the one that users preset. This approach employs an idea of quasi-closed-loop control system, and works in an iterative mode. It starts from initial values of the design variable sequences, and predicts better sequences via the feedback of the profile error between the output target profile and the expected one. It never stops until the profile error is narrowed in the preset tolerance.

36 MATERIALS SCIENCE↗

PHYSICAL PROPERTIES OF LARGE AND SMALL GRANULES IN SOLAR QUIET REGIONS

The normal mode observations of seven quiet regions obtained by the Hinode spacecraft are analyzed to study the physical properties of granules. An artificial intelligence technique is introduced to automatically find the spatial distribution of granules in feature spaces. In this work, we investigate the dependence of granular continuum intensity, mean Doppler velocity, and magnetic fields on granular diameter. We recognized 71,538 granules by an automatic segmentation technique and then extracted five properties: diameter, continuum intensity, Doppler velocity, and longitudinal and transverse magnetic flux density to describe the granules. To automatically explore the intrinsic structures of the granules in the five-dimensional parameter space, the X-means clustering algorithm and one-rule classifier are introduced to define the rules for classifying the granules. It is found that diameter is a dominating parameter in classifying the granules and two families of granules are derived: small granules with diameters smaller than 1.''44, and large granules with diameters larger than 1.''44. Based on statistical analysis of the detected granules, the following results are derived: (1) the averages of diameter, continuum intensity, and Doppler velocity in the upward direction of large granules are larger than those of small granules; (2) the averages of absolute longitudinal, transverse, and unsigned flux density of large granules are smaller than those of small granules; (3) for small granules, the average of continuum intensity increases with their diameters, while the averages of Doppler velocity, transverse, absolute longitudinal, and unsigned magnetic flux density decrease with their diameters. However, the mean properties of large granules are stable; (4) the intensity distributions of all granules and small granules do not satisfy Gaussian distribution, while that of large granules almost agrees with normal distribution with a peak at 1.04 I{sub 0}.

79 ASTRONOMY AND ASTROPHYSICS↗

Spatial Feature Evaluation for Aerial Scene Analysis

High-resolution aerial images are becoming more readily available, which drives the demand for robust, intelligent and efficient systems to process increasingly large amounts of image data. However, automated image interpretation still remains a challenging problem. Robust techniques to extract and represent features to uniquely characterize various aerial scene categories is key for automated image analysis. In this paper we examined the role of spatial features to uniquely characterize various aerial scene categories. We studied low-level features such as colors, edge orientations, and textures, and examined their local spatial arrangements. We computed correlograms representing the spatial correlation of features at various distances, then measured the distance between correlograms to identify similar scenes. We evaluated the proposed technique on several aerial image databases containing challenging aerial scene categories. We report detailed evaluation of various low-level features by quantitatively measuring accuracy and parameter sensitivity. To demonstrate the feature performance, we present a simple query-based aerial scene retrieval system.

Swearingen, Thomas S↗

Exploring the Spatial Control of Topotactic Phase Transitions Using Vertically Oriented Epitaxial Interfaces

Engineering oxygen vacancy formation and distribution is a powerful route for controlling the oxygen sublattice evolution that affects diverse functional behavior. The controlling of the oxygen vacancy formation process is particularly important for inducing topotactic phase transitions that occur by transformation of the oxygen sublattice. Here we demonstrate an epitaxial nanocomposite approach for exploring the spatial control of topotactic phase transition from a pristine perovskite phase to an oxygen vacancy-ordered brownmillerite (BM) phase in a model oxide La 0.7 Sr 0.3 MnO 3 (LSMO). Incorporating a minority phase NiO in LSMO films creates ultrahigh density of vertically aligned epitaxial interfaces that strongly influence the oxygen vacancy formation and distribution in LSMO. Combined structural characterizations reveal strong interactions between NiO and LSMO across the epitaxial interfaces leading to a topotactic phase transition in LSMO accompanied by significant morphology evolution in NiO. Using the NiO nominal ratio as a single control parameter, we obtain intermediate topotactic nanostructures with distinct distribution of the transformed LSMO-BM phase, which enables systematic tuning of magnetic and electrical transport properties. The use of self-assembled heterostructure interfaces by the epitaxial nanocomposite platform enables more versatile design of topotactic phase structures and correlated functionalities that are sensitive to oxygen vacancies.

36 MATERIALS SCIENCE↗

TU-EF-207-01: Introductory Remarks on Recent Advances in Breast Imaging

Breast imaging technology is advancing on several fronts. In digital mammography, the major technological trend has been on optimization of approaches for performing combined mammography and tomosynthesis using the same system. In parallel, photon-counting slot-scan mammography is now in clinical use and more efforts are directed towards further development of this approach for spectral imaging. Spectral imaging refers to simultaneous acquisition of two or more energy-windowed images. Depending on the detector and associated electronics, there are a number of ways this can be accomplished. Spectral mammography using photon-counting detectors can suppress electronic noise and importantly, it enables decomposition of the image into various material compositions of interest facilitating quantitative imaging. Spectral imaging can be particularly important in intravenously injected contrast mammography and eventually tomosynthesis. The various approaches and applications of spectral mammography are discussed. Digital breast tomosynthesis relies on the mechanical movement of the x-ray tube to acquire a number of projections in a predefined arc, typically from 9 to 25 projections over a scan angle of +/−7.5 to 25 degrees depending on the particular system. The mechanical x-ray tube motion requires relatively long acquisition time, typically between 3.7 to 25 seconds depending on the system. Moreover, mechanical scanning may have an effect on the spatial resolution due to internal x-ray filament or external mechanical vibrations. New x-ray source arrays have been developed and they are aimed at replacing the scanned x-ray tube for improved acquisition time and potentially for higher spatial resolution. The potential advantages and challenges of this approach are described. Combination of digital mammography and tomosynthesis in a single system places increased demands on certain functional aspects of the detector and overall performance, particularly in the tomosynthesis mode due to lower photon fluence per projection. This may require fast-frame acquisition and symmetric or asymmetric pixel binning in some systems. Recent studies investigated the performance of increased conversion layer thickness for contrast-enhanced imaging of the breast in dual-energy acquisition mode. In other direct conversion detectors operating in the avalanche mode, sensitivities close to the single photon response are also explored for mammography and breast tomosynthesis. The potential advantages and challenges of this approach are described. Dedicated breast CT brings x-ray imaging of the breast to true tomographic 3D imaging. It can eliminate the tissue superposition problem and does not require physical compression of the breast. Using cone beam geometry and a flat-panel detector, several hundred projections are acquired and reconstructed to near isotropic voxels. Multiplanar reconstruction facilitates viewing the breast volume in any desired orientation. Ongoing clinical studies, the current state-of-the art, and research to advance the technology are described. Learning Objectives: To understand the ongoing developments in x-ray imaging of the breast To understand the approaches and applications of spectral mammography To understand the potential advantages of distributed x-ray source arrays for digital breast tomosynthesis To understand the ongoing developments in detector technology for digital mammography and breast tomosynthesis To understand the current state-of-the-art for dedicated cone-beam breast CT and research to advance the technology. Research collaboration with Koning Corporation.

60 APPLIED LIFE SCIENCES↗