Search NASA⌕ Search

SEARCH · Search NASA

Results for “computer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Leveraging In-Network Computing and Programmable Switches for Streaming Analysis of Scientific Data

With the emergence of programmable network devices that match the performance of fixed function devices, several recent projects have explored in-network computing, where the processing that is traditionally done outside the network is offloaded to the network devices. In-network computing has typically been applied to network functions (e.g., load balancing, NAT, and DNS), caching, data reduction/aggregation, and coordination/consensus functions. In some cases it has been used to accelerate stream-processing tasks that involve small payloads and simple operations. In this work we focus on leveraging in-network computing for stream processing of scientific datasets with large payloads that require complex operations such as floating-point computations and logarithmic functions. We demonstrate in-network computing for a real-world scientific application performing streaming normalization of a 2-D image from a light source experiment. We discuss the challenges we encountered and potential approaches to address them.

Sankaran, Ganesh↗

Performance Portability of Molecular Docking Miniapp On Leadership Computing Platforms

Rapidly changing computer architectures, such as those found at high-performance computing (HPC) facilities, present the need for mini-applications (miniapps) that capture essential algorithms used in large applications to test program performance and portability, aiding transitions to new systems. The COVID-19 pandemic has fueled a flurry of activity in computational drug discovery, including the use of supercomputers and GPU acceleration for massive virtual screens for therapeutics. Recent work targeting COVID-19 at the Oak Ridge Leadership Computing Facility (OLCF) used the GPU-accelerated program AutoDock-GPU to screen billions of compounds on the Summit supercomputer. In this paper we present the development of a new miniapp, miniAutoDock-GPU, that can be used to evaluate the performance and portability of GPU-accelerated protein-ligand docking programs on different computer architectures. These tests are especially relevant as facilities transition from petascale systems and prepare for upcoming exascale systems that will use a variety of GPU vendors. The key calculations, namely, the Lamarckian genetic algorithm combined with a local search using a Solis-Wets based random optimization algorithm, are implemented. We developed versions of the miniapp using several different programming models for GPU acceleration, including a version using the CUDA runtime API for NVIDIA GPUs, and the Kokkos middle-ware API which is facilitated by C++ template libraries. A third version, currently in progress, uses the HIP programming model. These efforts will help facilitate the transition to exascale systems for this important emerging HPC application, as well as its use on a wide range of heterogeneous platforms.

Thavappiragasam, Mathialakan↗

Reliable Devices Yield Stable Quantum Computations

Stable quantum computation requires noisy results to remain bounded even in the presence of noise fluctuations. Yet non-stationary noise processes lead to drift in the varying characteristics of a quantum device that can greatly influence the circuit outcomes. Here we address how temporal and spatial variations in noise relate device reliability to quantum computing stability. First, our approach quantifies the differences in statistical distributions of characterization metrics collected at different times and locations using Hellinger distance. We then validate an analytical bound that relates this distance directly to the stability of a computed expectation value. Our demonstration uses numerical simulations with models informed by the washington superconducting transmon device. We find that the stability metric is consistently bounded from above by the corresponding Hellinger distance, which can be cast as a specified tolerance level. These results underscore the significance of reliable quantum computing devices and the impact for stable quantum computation.

Dasgupta, Samudra↗

Neuromorphic Computing for Scientific Applications

Neuromorphic computing technology continues to make strides in the development of new algorithms, devices, and materials. In addition, applications have begun to emerge where neuromorphic computing shows promising results. However, numerous barriers to further development and application remain. In this work, we identify several science areas where neuromorphic computing can either make an immediate impact (within 1 to 3 years) or the societal impact would be extremely high if the technological barriers can be addressed. We identify both opportunities and hurdles to the development of neuromorphic computing technology for these areas. Finally, we discuss future directions that need to be addressed to expand both the development and application of neuromorphic computing.

Patton, Robert↗

Design-to-Deployment Continuum Platform for Microscopes and Computing Ecosystems

Science ecosystems with networked computing systems and physical instruments are increasingly being deployed with a goal to achieve the productivity promised by AI-supported remote automation. In support of these efforts, the virtual infrastructure twins (VITs) have been successfully utilized to develop the orchestration codes for these ecosystems without requiring physical access to expensive instruments, such as electron microscopes. Currently, the utility of such a VIT is severely limited by the computing capacity and capability of the computing system used as its host. Furthermore, codes developed on the VIT typically need to be transferred and refactored for production use, particularly, on high-performance systems with accelerators. In response, we develop a design-to-deployment continuum platform wherein a VIT runs natively on the ecosystem's own computing system, and thereby facilitates the continual in-situ testing and transition of codes for production use. Here, we describe the development and testing of software for remote microscope steering and GPU-based image reconstruction using this platform on a multi-GPU computing system networked to Nion microscopes. We demonstrate a continual transition of steering and reconstruction codes developed under VIT platform to production ecosystem deployment.

Al-Najjar, Anees [Oak Ridge National Laboratory (O↗

Computational and Experimental Study of Film-Cooling Effectiveness With and Without Downstream Vortex Generators

Downstream vortex generators that involve a pair of rectangular plates arranged in an open V-shape placed just downstream of each film-cooling hole were shown to create flow and vortical structures that entrain lifted film-cooling flow back to the surface and increase its lateral spreading on the surface (GT2020–14317). In this study, computations and measurements were performed to examine the flow mechanisms this vortex generator induces to improve film-cooling effectiveness of a flat plate with the cooling flow emanating from one row of inclined holes. Parameters studied include blowing ratio (BR = 0.75 and 1.0) and temperature ratio (TR = 1.07 and 1.9). Here, the computational study is based on steady Reynolds-averaged Navier–Stokes (RANS) closed by the shear-stress transport (SST) turbulence model with and without conjugate analysis. The experimental study was conducted by using a conjugate heat transfer test rig with a plenum, where cooling flow is introduced. Measurements made include velocity and temperature profiles upstream and downstream of the film-cooling holes as well as the temperature at several locations on the hot and cold sides of the film-cooled flat plate. The computational study was validated by comparing computed results with those from measurements at BR = 0.75 and 1.0 and TR = 1.9. Computational and experimental results are presented to show the effects of BR and TR on the flow structures and how those structures improve the effectiveness of film cooling with and without the downstream vortex generators and with and without conjugate heat transfer.

42 ENGINEERING↗

Hydrodynamic Analysis of a Suspended Cylinder Under Regular Wave Loading Based on Computational Fluid Dynamics

An investigation into the computation of hydrodynamic loads on a suspended cylinder in regular waves is presented. The primary goal was to perform a three-way validation of the loads between experimental measurements and simulations from two computational methods. Experimental measurements of the longitudinal in-line force on a cylinder suspended at a fixed position were available from the Offshore Code Comparison Collaboration, Continued, with Correlation (OC5) project, Phase Ia. These measurements were compared to computational fluid dynamics (CFD) simulations based on the solution of Reynolds-averaged Navier-Stokes (RANS) equations, as implemented in STAR-CCM+. The study encompassed a sensitivity analysis of the loads computed in STAR-CCM+ based on wave modeling, boundary conditions, turbulence modeling, and spatial and temporal discretization. The analysis was supplemented by results generated with the offshore wind turbine engineering software OpenFAST, based on a hybrid combination of second-order potential flow and viscous drag from Morison's equation. The focus of the investigation was on the assessment of the accuracy of the computation of first- and higher-order hydrodynamic loads. Substantial differences were observed in the numerical prediction of the second and third harmonic force contribution. Local flow field analysis with CFD was applied to study the physics of wave run-up and diffraction dynamics to identify the causes.

16 TIDAL AND WAVE POWER↗

Validating an operational physical method to compute surface radiation from geostationary satellites

We developed models to compute global horizontal irradiance (GHI) and direct normal irradiance (DNI) over the last three decades. These models can be classified as empirical or physical based on the approach. Empirical models relate ground-based observations with satellite measurements and use these relations to compute surface radiation. Physical models consider the physics behind the radiation received at the satellite and create retrievals to estimate surface radiation. Furthermore, while empirical methods have been traditionally used for computing surface radiation for the solar energy industry, the advent of faster computing has made operational physical models viable. The Global Solar Insolation Project (GSIP) is a physical model that computes DNI and GHI using the visible and infrared channel measurements from a weather satellite. GSIP uses a two-stage scheme that first retrieves cloud properties and uses those properties in a radiative transfer model to calculate GHI and DNI. Developed for polar orbiting satellites, GSIP has been adapted to NOAA's Geostationary Operation Environmental Satellite series and can run operationally at high spatial resolutions. Our method holds the possibility of creating high quality datasets of GHI and DNI for use by the solar energy industry. We present an outline of the methodology and results from running the model as well as a validation study using ground-based instruments.

14 SOLAR ENERGY↗

Validation of an image simulation technique for two computed radiography systems: An application to neonatal imaging

Purpose: The purpose of this study is to develop a computer model to simulate the image acquisition for two computed radiography (CR) imaging systems used for neonatal chest imaging: (1) The Agfa ADC Compact, a flying spot reader with powder phosphor image plates (MD 40.0); and (2) the Agfa DX-S, a line-scanning CR reader with needle crystal phosphor image plates (HD 5.0). The model was then applied to compare the image quality of the two CR imaging systems. Methods: Monte Carlo techniques were used to simulate the transport of primary and scattered x rays in digital x-ray systems. The output of the Monte Carlo program was an image representing the energy absorbed in the detector material. This image was then modified using physical characteristics of the CR imaging systems to account for the signal intensity variations due to the heel effect along the anode-cathode axis, the spatial resolution characteristics of the imaging system, and the various sources of image noise. The simulation was performed for typical acquisition parameters of neonatal chest x-ray examinations. To evaluate the computer model, the authors compared the threshold-contrast detectability in simulated and experimentally acquired images of a contrast-detail phantom. Threshold-contrast curves were computed using a commercially available scoring program. Results: The threshold-contrast curves of the simulated and experimentally acquired images show good agreement; for the two CR systems, 93% of the threshold diameters calculated from the simulated images fell within the confidence intervals of the threshold diameter calculated from the experimentally assessed images. Moreover, the superiority of needle based CR plates for neonatal imaging was confirmed. Conclusions: The good agreement between simulated and experimental acquired results indicates that the computer model is accurate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric characterization of a dedicated breast computed tomography clinical prototype

Purpose: To investigate the glandular dose magnitudes and characteristics resulting from image acquisition using a dedicated breast computed tomography (BCT) clinical prototype imaging system. Methods: The x-ray spectrum and output characteristics of a BCT clinical prototype (Koning Corporation, West Henrietta, NY) were determined using empirical measurements, breast phantoms, and an established spectrum model. The geometry of the BCT system was replicated in a Monte Carlo-based computer simulation using the GEANT4 toolkit and was validated by comparing the simulated results for exposure distribution in a standard 16 cm CT head phantom with those empirically determined using a 10 cm CT pencil ionization chamber and dosimeter. The computer simulation was further validated by replicating the results of a previous BCT dosimetry study. Upon validation, the computer simulation was modified to include breasts of varying sizes and homogeneous compositions spanning those encountered clinically, and the normalized mean glandular dose resulting from BCT was determined. Using the system's measured exposure output determined automatically for breasts of different size and density, the mean glandular dose for these breasts was computed and compared to the glandular dose resulting from mammography. Finally, additional Monte Carlo simulations were performed to study how the glandular dose values vary within the breast tissue during acquisition with both this BCT prototype and a typical craniocaudal (CC) mammographic acquisition. Results: This BCT prototype uses an x-ray spectrum with a first half-value layer of 1.39 mm Al and a mean x-ray energy of 30.3 keV. The normalized mean glandular dose for breasts of varying size and composition during BCT acquisition with this system ranges from 0.278 to 0.582 mGy/mGy air kerma with the reference air kerma measured in air at the center of rotation. Using the measured exposure outputs for the tube currents automatically selected by the system for the breasts of different sizes and densities, the mean glandular dose for a BCT acquisition with this prototype system varies from 5.6 to 17.5 mGy, with the value for a breast of mean size and composition being 17.06 mGy. The glandular dose throughout the breast tissue of this mean breast varies by up to {+-}50% of the mean value. During a typical CC view mammographic acquisition of an equivalent mean breast, which typically results in a mean glandular dose of 2.0-2.5 mGy, the glandular dose throughout the breast tissue varies from {approx}15% to {approx}400% of the mean value. Conclusions: Acquisition of a BCT image with the automated tube output settings for a mean breast with the Koning Corp. clinical prototype results in mean glandular dose values approximately equivalent to three to five two-view mammographic examinations for a similar breast. For all breast sizes and compositions studied, this glandular dose ratio between acquisition with this BCT prototype and two-view mammography ranges from 1.4 to 7.2. In mammography, portions of the mean-sized breast receive a considerably higher dose than the mean value for the whole breast. However, only a small portion of a breast undergoing mammography would receive a glandular dose similar to that from BCT.

60 APPLIED LIFE SCIENCES↗

Four-dimensional volume-of-interest reconstruction for cone-beam computed tomography-guided radiation therapy

Purpose: Data sufficiency are a major problem in four-dimensional cone-beam computed tomography (4D-CBCT) on linear accelerator-integrated scanners for image-guided radiotherapy. Scan times must be in the range of 4-6 min to avoid undersampling artifacts. Various image reconstruction algorithms have been proposed to accommodate undersampled data acquisitions, but these algorithms are computationally expensive, may require long reconstruction times, and may require algorithm parameters to be optimized. The authors present a novel reconstruction method, 4D volume-of-interest (4D-VOI) reconstruction which suppresses undersampling artifacts and resolves lung tumor motion for undersampled 1-min scans. The 4D-VOI reconstruction is much less computationally expensive than other 4D-CBCT algorithms. Methods: The 4D-VOI method uses respiration-correlated projection data to reconstruct a four-dimensional (4D) image inside a VOI containing the moving tumor, and uncorrelated projection data to reconstruct a three-dimensional (3D) image outside the VOI. Anatomical motion is resolved inside the VOI and blurred outside the VOI. The authors acquired a 1-min. scan of an anthropomorphic chest phantom containing a moving water-filled sphere. The authors also used previously acquired 1-min scans for two lung cancer patients who had received CBCT-guided radiation therapy. The same raw data were used to test and compare the 4D-VOI reconstruction with the standard 4D reconstruction and the McKinnon-Bates (MB) reconstruction algorithms. Results: Both the 4D-VOI and the MB reconstructions suppress nearly all the streak artifacts compared with the standard 4D reconstruction, but the 4D-VOI has 3-8 times greater contrast-to-noise ratio than the MB reconstruction. In the dynamic chest phantom study, the 4D-VOI and the standard 4D reconstructions both resolved a moving sphere with an 18 mm displacement. The 4D-VOI reconstruction shows a motion blur of only 3 mm, whereas the MB reconstruction shows a motion blur of 13 mm. With graphics processing unit hardware used to accelerate computations, the 4D-VOI reconstruction required a 40-s reconstruction time. Conclusions: 4D-VOI reconstruction effectively reduces undersampling artifacts and resolves lung tumor motion in 4D-CBCT. The 4D-VOI reconstruction is computationally inexpensive compared with more sophisticated iterative algorithms. Compared with these algorithms, our 4D-VOI reconstruction is an attractive alternative in 4D-CBCT for reconstructing target motion without generating numerous streak artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-220: Computational Accuracy of Adaptive Convolution (AC) and Collapsed Cone Convolution (CCC) Algorithms in the Presence of Air Gaps

Purpose: To compare the percentage depth dose (PDD) computational accuracy of Adaptive Convolution (AC) and Collapsed Cone Convolution (CCC) algorithms in the presence of air gaps. Methods: A 30×30×30 cm{sup 3} solid water phantom with two 5cm air gaps was scanned with a CT simulator unit and exported into the Phillips Pinnacle™ treatment planning system. PDDs were computed using the AC and CCC algorithms. Photon energy of 6 MV was used with field sizes of 3×3 cm{sup 2}, 5×5 cm{sup 2}, 10×10 cm{sup 2}, 15×15 cm{sup 2}, and 20×20 cm{sup 2}. Ionization chamber readings were taken at different depths in water for all the field sizes. The percentage differences in the PDDs were computed with normalization to the depth of maximum dose (dmax). The calculated PDDs were then compared with measured PDDs. Results: In the first buildup region, both algorithms overpredicted the dose for all field sizes and under-predicted for all other subsequent buildup regions. After dmax in the three water media, AC under-predicted the dose for field sizes 3×3 and 5×5 cm{sup 2} and overpredicted for larger field sizes, whereas CCC under-predicted for all field sizes. Upon traversing the first air gap, AC showed maximum differences of –3.9%, −1.4%, 2.0%, 2.5%, 2.9% and CCC had maximum differences of −3.9%, −3.0%,–3.1%, −2.7%, −1.8% for field sizes 3×3, 5×5, 10×10, 15×15, and 20×20 cm{sup 2} respectively. Conclusion: The effect of air gaps causes a significant difference in the PDDs computed by both the AC and CCC algorithms in secondary build-up regions. AC computed larger values for the PDDs except at smaller field sizes. For CCC, the size of the errors in prediction of the PDDs has an inverse relationship with respect to field size. These effects should be considered in treatment planning where significant air gaps are encountered.

60 APPLIED LIFE SCIENCES↗

A Distributed-Memory Package for Dense Hierarchically Semi-Separable Matrix Computations Using Randomization

In this paper, we present a distributed-memory library for computations with dense structured matrices. A matrix is considered structured if its off-diagonal blocks can be approximated by a rank-deficient matrix with low numerical rank. Here, we use Hierarchically Semi-Separable (HSS) representations. Such matrices appear in many applications, for example, finite-element methods, boundary element methods, and so on. Exploiting this structure allows for fast solution of linear systems and/or fast computation of matrix-vector products, which are the two main building blocks of matrix computations. The compression algorithm that we use, that computes the HSS form of an input dense matrix, relies on randomized sampling with a novel adaptive sampling mechanism. We discuss the parallelization of this algorithm and also present the parallelization of structured matrix-vector product, structured factorization, and solution routines. The efficiency of the approach is demonstrated on large problems from different academic and industrial applications, on up to 8,000 cores. Finally, this work is part of a more global effort, the STRUctured Matrices PACKage (STRUMPACK) software package for computations with sparse and dense structured matrices. Hence, although useful on their own right, the routines also represent a step in the direction of a distributed-memory sparse solver.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

PIMS: A Lightweight Processing-in-Memory Accelerator for Stencil Computations

Stencil computation is a classic computational kernel present in many high-performance scientific applications, like image process- ing and partial differential equation solvers (PDE). A stencil compu- tation sweeps over a multi-dimensional grid and repeatedly updates values associated with points using the values from neighboring points. Stencil computations often employ large datasets that ex- ceed cache capacity, leading to excessive accesses to the memory subsystem. As such, 3D stencil computations on large grid sizes are memory-bound. In this paper we present PIMS, an in-memory accelerator for stencil computations. PIMS, implemented in the logic layer of a 3D- stacked memory, exploits the high bandwidth provided by through- silicon vias to reduce redundant memory traffic. Our comprehensive evaluation using three different grid sizes with six categories of orders indicate that the proposed architecture reduces 48.25% of data movement on average and obtains up to 65.55% of bank conflict reduction.

Li, Jie↗

A single-tree algorithm to compute the Euclidean minimum spanning tree on GPUs

Computing the Euclidean minimum spanning tree (Emst) is a computationally demanding step of many algorithms. While work-efficient serial and multithreaded algorithms for computing Emst are known, designing an efficient GPU algorithm is challenging due to a complex branching structure, data dependencies, and load imbalances. In this paper, we propose a single-tree $Bor\mathring{u}vka$-based algorithm for computing Emst on GPUs. We use an efficient nearest neighbor algorithm and reduce the number of the required distance calculations by avoiding traversing subtrees with leaf nodes in the same component. The developed algorithms are implemented in a performance portable way using ArborX, an open-source geometric search library based on the Kokkos framework. We evaluate the proposed algorithm on various 2D and 3D datasets, show and compare it with the current state-of-the-art open-source CPU implementations. We demonstrate 4-24 × speedup over the fastest multi-threaded implementation. We prove the portability of our implementation by providing results on a variety of hardware: AMD EPYC 7763, Nvidia A100 and AMD MI250X. We show scalability of the implementation, computing Emst for 37 million 3D cosmological dataset in under a 0.5 second on a single A100 Nvidia GPU.

Prokopenko, Andrey↗

Extensible Computational Chemistry Environment

ECCE provides a sophisticated graphical user interface, scientific visualization tools, and the underlying data management framework enabling scientists to efficiently set up calculations and store, retrieve, and analyze the rapidly growing volumes of data produced by computational chemistry studies. ECCE was conceived as part of the Environmental Molecular Sciences Laboratory construction to solve the problem of researchers being able to effectively utilize complex computational chemistry codes and massively parallel high performance compute resources. Bringing the power of these codes and resources to the desktops of researcher and thus enabling world class research without users needing a detailed understanding of the inner workings of either the theoretical codes or the supercomputers needed to run them was a grand challenge problem in the original version of the EMSL. ECCE allows collaboration among researchers using a web-based data repository where the inputs and results for all calculations done within ECCE are organized. ECCE is a first of kind end-to-end problem solving environment for all phases of computational chemistry research: setting up calculations with sophisticated GUI and direct manipulation visualization tools, submitting and monitoring calculations on remote high performance supercomputers without having to be familiar with the details of using these compute resources, and performing results visualization and analysis including creating publication quality images. ECCE is a suite of tightly integrated applications that are employed as the user moves through the modeling process.

Source record↗

The NEAMS Integrated Computational Environment (NiCE)

Many new, high-performance nuclear energy modeling and simulation tools are under development in the United States and many more existing projects are moving to high-performance computing. This shift to state-of-the-art modeling and simulation will not only result in an unprecedented use of computing resources but it will generate extremely large amounts of data in extraordinary detail. Domain scientists will find themselves simultaneously in two positions: managing the complexity of their own problem domain and managing the complexity of a nightmarish scenario of high-performance computational tools. We believe that the computational science community should develop integrated tools for coupling, working with and analyzing data from simulation codes instead of leaving domains scientists and students to fend for themselves and come up with a “working” solution. While many projects offer some set of tools to work with their codes, to launch jobs remotely or to setup input files, most of these tools are rarely integrated in a holistic way to provide an easy, common and high-productivity environment for users. For that matter, most remote jobs are launched on “the machine in the other room,” but that certainly will not work for larger problems that require Leadership Class computing resources found only at U.S. National Laboratories or similar facilities. Overcoming the challenges of launching on these machines and even on public or private “clouds” are left as a challenge to the user.

Source record↗

Computational Modeling to Advance Novel Medical Isotopes for Radiotheranostics: A DOE-NIH Joint Workshop Executive Summary

The DOE-NIH Joint Workshop on Computational Modeling to Advance Novel Medical Isotopes for Radiotheranostics, held on September 27, 2024, brought together experts from government, academia, and industry to address critical challenges in radionuclide production and clinical translation. Here, the workshop emphasized interdisciplinary collaboration, particularly between the Department of Energy (DOE) and the National Institutes of Health (NIH), to strengthen the domestic isotope supply, streamline regulatory pathways, and further integrate computational tools into radiopharmaceutical therapy (RPT). Key discussions explored the role of AI-driven modeling, machine learning, and digital twin technologies in optimizing dosimetry, dynamically personalizing treatments, and reducing time to clinical adoption. Advances in predictive computational modeling were highlighted as essential for improving radionuclide yield, purity, and synthesis efficiency. Regulatory considerations and equitable access were central themes, with participants advocating for harmonized global standards, adaptive trial designs, and expanded infrastructure for clinical implementation. DOE computational and production infrastructure was emphasized. Future priorities identified include increased investment in radionuclide production infrastructure, expanded workforce development in radiopharmaceutical sciences and computational modeling, and the creation of robust public-private partnerships. The workshop concluded that continued strategic collaboration and sustained resources will be vital for advancing next-generation radiotheranostics, ensuring safe and effective therapies accessible to all patients.

digital twins↗