Search NASA⌕ Search

SEARCH · Search NASA

Results for “deformable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Interactive Streamline Exploration and Manipulation Using Deformation

Occlusion presents a major challenge in visualizing three-dimensional flow fields with streamlines. Displaying too many streamlines at once makes it difficult to locate interesting regions, but displaying too few streamlines risks missing important features. A more ideal streamline exploration model is to allow the viewer to freely move across the field that has been populated with interesting streamlines and pull away the streamlines that cause occlusion so that the viewer can inspect the hidden ones in detail. In this paper, we present a streamline deformation algorithm that supports such user-driven interaction with three-dimensional flow fields. We define a view-dependent focus+context technique that moves the streamlines occluding the focus area using a novel displacement model. To preserve the context surrounding the user-chosen focus area, we propose two shape models to define the transition zone for the surrounding streamlines, and the displacement of the contextual streamlines is solved interactively with a goal of preserving their shapes as much as possible. Based on our deformation model, we design an interactive streamline exploration tool using a lens metaphor. Our system runs interactively so that users can move their focus and examine the flow field freely.

flow visualization, focus+context, streamline, def↗

Effects of Rutherford Cable Parameters on Nb3Sn Extracted Strand Deformation and Performance

In order to optimize parameters for Rutherford cables used in accelerator magnets, a number of cables were fabricated with different keystone angles, packing factors and numbers of strands. The effect of these parameters was measured on Nb{sub 3}Sn strand performance and deformation for two different RRP designs. High and low field current carrying capabilities and RRR were measured for the extracted strands. To correlate strand deformation with performance, the former was measured for several cables and conditions as a function of the strand location in the cable cross section.

43 PARTICLE ACCELERATORS↗

Finite Element Modeling of the Deformation of a Thin Magnetoelastic Film Compared to a Membrane Model

Recently a new class of biocompatible elastic polymers loaded with small ferrous particles (magnetoelastomer) was developed at Lawrence Livermore National Laboratory. This new material was formed as a thin film using spin casting. The deformation of this material using a magnetic field has many possible applications to microfluidics. Two methods will be used to calculate the deformation of a circular magneto-elastomeric film subjected to a magnetic field. The first method is an arbitrary Lagrangian-Eulerian (ALE) finite element method (FEM) and the second is based on nonlinear continuum electromagnetism and continuum elasticity in the membrane limit. The comparison of these two methods is used to test/validate the finite element method.

36 MATERIALS SCIENCE↗

Deformation of multilayer flexible electronics subjected to torque

Flexibility is one of remarkable characteristics of flexible electronics. Therefore, the analysis of flexible electronics deformation caused by external torques will help its design. In this work, analytical derivation is conducted for flexible electronics treated as multilayer structures. In experiments, an electric motor under computer control exerts a torque to generate torsion, whose twist angles are obtained by using both optical encoder measurement and theoretical calculation. Comparisons are made between experimental and theoretical results for bare PEN (polyethylene naphthalate) substrates of different sizes, multilayer PET (polyethylene terephthalate) substrates, and ITO (indium tin oxide)-coated PET substrates. Finally, a laser displacement sensor is used to measure the out-of-plane deformation for validating the proposed theoretical model.

36 MATERIALS SCIENCE↗

Dynamic estimation of three-dimensional cerebrovascular deformation from rotational angiography

Purpose: The objective of this study is to investigate the feasibility of detecting and quantifying 3D cerebrovascular wall motion from a single 3D rotational x-ray angiography (3DRA) acquisition within a clinically acceptable time and computing from the estimated motion field for the further biomechanical modeling of the cerebrovascular wall. Methods: The whole motion cycle of the cerebral vasculature is modeled using a 4D B-spline transformation, which is estimated from a 4D to 2D+t image registration framework. The registration is performed by optimizing a single similarity metric between the entire 2D+t measured projection sequence and the corresponding forward projections of the deformed volume at their exact time instants. The joint use of two acceleration strategies, together with their implementation on graphics processing units, is also proposed so as to reach computation times close to clinical requirements. For further characterizing vessel wall properties, an approximation of the wall thickness changes is obtained through a strain calculation. Results: Evaluation on in silico and in vitro pulsating phantom aneurysms demonstrated an accurate estimation of wall motion curves. In general, the error was below 10% of the maximum pulsation, even in the situation when substantial inhomogeneous intensity pattern was present. Experiments on in vivo data provided realistic aneurysm and vessel wall motion estimates, whereas in regions where motion was neither visible nor anatomically possible, no motion was detected. The use of the acceleration strategies enabled completing the estimation process for one entire cycle in 5-10 min without degrading the overall performance. The strain map extracted from our motion estimation provided a realistic deformation measure of the vessel wall. Conclusions: The authors' technique has demonstrated that it can provide accurate and robust 4D estimates of cerebrovascular wall motion within a clinically acceptable time, although it has to be applied to a larger patient population prior to possible wide application to routine endovascular procedures. In particular, for the first time, this feasibility study has shown that in vivo cerebrovascular motion can be obtained intraprocedurally from a 3DRA acquisition. Results have also shown the potential of performing strain analysis using this imaging modality, thus making possible for the future modeling of biomechanical properties of the vascular wall.

60 APPLIED LIFE SCIENCES↗

Demons deformable registration of CT and cone-beam CT using an iterative intensity matching approach

Purpose: A method of intensity-based deformable registration of CT and cone-beam CT (CBCT) images is described, in which intensity correction occurs simultaneously within the iterative registration process. The method preserves the speed and simplicity of the popular Demons algorithm while providing robustness and accuracy in the presence of large mismatch between CT and CBCT voxel values (''intensity''). Methods: A variant of the Demons algorithm was developed in which an estimate of the relationship between CT and CBCT intensity values for specific materials in the image is computed at each iteration based on the set of currently overlapping voxels. This tissue-specific intensity correction is then used to estimate the registration output for that iteration and the process is repeated. The robustness of the method was tested in CBCT images of a cadaveric head exhibiting a broad range of simulated intensity variations associated with x-ray scatter, object truncation, and/or errors in the reconstruction algorithm. The accuracy of CT-CBCT registration was also measured in six real cases, exhibiting deformations ranging from simple to complex during surgery or radiotherapy guided by a CBCT-capable C-arm or linear accelerator, respectively. Results: The iterative intensity matching approach was robust against all levels of intensity variation examined, including spatially varying errors in voxel value of a factor of 2 or more, as can be encountered in cases of high x-ray scatter. Registration accuracy without intensity matching degraded severely with increasing magnitude of intensity error and introduced image distortion. A single histogram match performed prior to registration alleviated some of these effects but was also prone to image distortion and was quantifiably less robust and accurate than the iterative approach. Within the six case registration accuracy study, iterative intensity matching Demons reduced mean TRE to (2.5{+-}2.8) mm compared to (3.5{+-}3.0) mm with rigid registration. Conclusions: A method was developed to iteratively correct CT-CBCT intensity disparity during Demons registration, enabling fast, intensity-based registration in CBCT-guided procedures such as surgery and radiotherapy, in which CBCT voxel values may be inaccurate. Accurate CT-CBCT registration in turn facilitates registration of multimodality preoperative image and planning data to intraoperative CBCT by way of the preoperative CT, thereby linking the intraoperative frame of reference to a wealth of preoperative information that could improve interventional guidance.

60 APPLIED LIFE SCIENCES↗

Localization of deformable tumors from short-arc projections using Bayesian estimation

Purpose: The authors present a stochastic framework for radiotherapy patient positioning directly utilizing radiographic projections. This framework is developed to be robust against anatomical nonrigid deformations and to cope with challenging imaging scenarios, involving only a few cone beam CT projections from short arcs. Methods: Specifically, a Bayesian estimator (BE) is explicitly derived for the given scanning geometry. This estimator is compared to reference methods such as chamfer matching (CM) and the minimization of the median absolute error adapted as tools of robust image processing and statistics. In order to show the performance of the stochastic short-arc patient positioning method, a CIRS IMRT thorax phantom study is presented with movable markers and the utilization of an Elekta Synergy{sup Registered-Sign} XVI system. Furthermore, a clinical prostate CBCT scan of a Varian{sup Registered-Sign} On-Board Imager{sup Registered-Sign} system is utilized to investigate the robustness of the method for large variations of image quality (anterior-posterior vs lateral views). Results: The results show that the BE shifts reduce the initial setup error of up to 3 cm down to 3 mm at maximum for an imaging arc as short as 10 Degree-Sign while CM achieves residual errors of 7 mm at maximum only for arcs longer than 40 Degree-Sign . Furthermore, the BE can compensate robustly for low image qualities using several low quality projections simultaneously. Conclusions: In conclusion, an estimation method for marker-based patient positioning for short imaging arcs is presented and shown to be robust and accurate for deformable anatomies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-127: Real-Time Dosimetric Assessment for Adaptive Head-And-Neck Treatment Via A GPU-Based Deformable Image Registration Framework

Purposes: To systematically monitor anatomic variations and their dosimetric consequences during head-and-neck (H'N) radiation therapy using a GPU-based deformable image registration (DIR) framework. Methods: Eleven H'N IMRT patients comprised the subject population. The daily megavoltage CT and weekly kVCT scans were acquired for each patient. The pre-treatment CTs were automatically registered with their corresponding planning CT through an in-house GPU-based DIR framework. The deformation of each contoured structure was computed to account for non-rigid change in the patient setup. The Jacobian determinant for the PTVs and critical structures was used to quantify anatomical volume changes. Dose accumulation was performed to determine the actual delivered dose and dose accumulation. A landmark tool was developed to determine the uncertainty in the dose distribution due to registration error. Results: Dramatic interfraction anatomic changes leading to dosimetric variations were observed. During the treatment courses of 6–7 weeks, the parotid gland volumes changed up to 34.7%, the center-of-mass displacement of the two parotids varied in the range of 0.9–8.8mm. Mean doses were within 5% and 3% of the planned mean doses for all PTVs and CTVs, respectively. The cumulative minimum/mean/EUD doses were lower than the planned doses by 18%, 2%, and 7%, respectively for the PTV1. The ratio of the averaged cumulative cord maximum doses to the plan was 1.06±0.15. The cumulative mean doses assessed by the weekly kVCTs were significantly higher than the planned dose for the left-parotid (p=0.03) and right-parotid gland (p=0.006). The computation time was nearly real-time (∼ 45 seconds) for registering each pre-treatment CT to the planning CT and dose accumulation with registration accuracy (for kVCT) at sub-voxel level (<1.5mm). Conclusions: Real-time assessment of anatomic and dosimetric variations is feasible using the GPU-based DIR framework. Clinical implementation of this technology may enable timely plan adaption and potentially lead to improved outcome.

60 APPLIED LIFE SCIENCES↗

TH-CD-207A-05: Lung Surface Deformation Vector Fields Prediction by Monitoring Respiratory Surrogate Signals

Purpose: In this study, we developed and evaluated a method for predicting lung surface deformation vector fields (SDVFs) based on surrogate signals such as chest and abdomen motion at selected locations and spirometry measurements. Methods: A Patient-specific 3D triangular surface mesh of the lung region at end-expiration (EE) phase was obtained by threshold-based segmentation method. For each patient, a spirometer recorded the flow volume changes of the lungs; and 192 selected points at a regular spacing of 2cm X 2cm matrix points over a total area of 34cm X 24cm on the surface of chest and abdomen was used to detect chest wall motions. Preprocessing techniques such as QR factorization with column pivoting (QRCP) were employed to remove redundant observations of the chest and abdominal area. To create a statistical model between the lung surface and the corresponding surrogate signals, we developed a predictive model based on canonical ridge regression (CRR). Two unique weighting vectors were selected for each vertex on the surface of the lung, and they were optimized during the training process using the all other phases of 4D-CT except the end-inspiration (EI) phase. These parameters were employed to predict the vertices locations of a testing data set, which was the EI phase of 4D-CT. Results: For ten lung cancer patients, the deformation vector field of each vertex of lung surface mesh was estimated from the external motion at selected positions on the chest wall surface plus spirometry measurements. The average estimation of 98th percentile of error was less than 1 mm (AP= 0.85, RL= 0.61, and SI= 0.82). Conclusion: The developed predictive model provides a non-invasive approach to derive lung boundary condition. Together with personalized biomechanical respiration modelling, the proposed model can be used to derive the lung tumor motion during radiation therapy accurately from non-invasive measurements.

60 APPLIED LIFE SCIENCES↗

Local reversible martensitic transformations as mechanisms of crystal deformation and reorientation in fcc metals

The results of studying the new mechanisms of crystal lattice deformation and reorientation-forward + reverse (over alternative systems) martensitic transformations in fcc metals (pure metals, austenitic steels, Ni{sub 3}Al alloys)-are generalized. The experimental results lying in the basis of the concepts developed are briefly reviewed. The atomic models of these transformations are presented. The mechanisms proposed make it possible to describe in a unified way a number of plastic deformation phenomena: dislocation nucleation, mechanical twinning, and the formation of strain localization bands with high-angle misorientation boundaries.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electronic structure of a deformable trimer with a coulomb interaction and a variable number of electrons

The electronic spectrum of a trimer with a variable number of electrons has been calculated in the Hubbard model by exact diagonalization. The dependences of the chemical potential shift, magnetic moment, and energy level splitting near the chemical potential on the magnetic field, Coulomb interaction between the electrons located at the vertices of the triangle, trimer deformation, and three-center interaction have been established. The removal of magnetic degeneracy in the trimer when the intersite Coulomb and three-center interactions are taken into account and the formation of a singlet pair of electrons under trimer deformation have been detected.

74 ATOMIC AND MOLECULAR PHYSICS↗

Formation of a disordered (Glassy) phase in deformed solid {sup 4}He in the region of supersolid state

A method has been proposed to create disorder in helium crystals by their deformation immediately during the experiment. Precise measurements of the pressure have been performed at a constant volume in samples of various qualities. It has been revealed that excess pressure, which is characterized by the quadratic temperature dependence typical of the disordered glassy phase and of the dislocation contribution to the pressure, is observed in the deformed crystals along with the phonon contribution to the pressure. The effect is observed in the supersolid-state region and disappears after the careful annealing of the crystals. The ultraslow relaxation of the pressure also characteristic of the glassy phase has been observed in the process of annealing of the crystals. The obtained experimental results have been analyzed in the framework of the dislocation model and the model of two-level tunneling states.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Phonon-deformational generalized ginzburg-landau functionals for describing martensite transitions between FCC and BCC structures in metals

A method is developed for theoretical description of martensite transitions between fcc and bcc phases of metals based on generalized Ginzburg-Landau functionals (GGLFs), in which the transformation parameters are the 'phonon' parameter describing relative slips of close-packed atomic planes and fcc lattice deformations in the region of a martensite inclusion. General expressions are proposed for calculating the deformational contributions to the GGLF. Local strains and local elastic moduli in the region of martensite inclusions are estimated numerically. The possibility of constructing phenomenological expressions for the GGLF using interpolations of available experimental data on the structure and elastic moduli in the fcc and bcc phases is discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nucleon states of strongly deformed nuclei and dinuclear systems in the nonoscillator two-center model

A new method for numerically solving the Schroedinger equation for an arbitrary axisymmetric field with allowance for spin-orbit interaction is used to study neutron and proton states in strongly deformed nuclei and dinuclear systems produced at the first step of the fusion of nuclei. A quadrupole-octupole parametrization is proposed for the shape of a dinuclear system and for the potential energy of nucleons in this system. The experimentally observed deformations of the {sup 26,27,28}Mg nuclei and the difference in the cross sections for the fusion of nuclei in the {sup 18}O + {sup 58}Ni and {sup 16}O + {sup 60}Ni systems are explained qualitatively.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis of the Optical Properties of Plastically Deformed ZnS(O) Using Band-Anticrossing Theory

The cathodoluminescence and absorption of plastically deformed ZnS(O) single crystals are investigated in the light of band-anticrossing theory. The difference in the oxygen content in the surface layer and in the sample bulk is found using a scanning electron microscope and according to cathodoluminescence data. This fact explains the specifics of the spectral position of the fundamental absorption edge and exciton spectra. The shift dynamics of the bands of self-activated luminescence on deep A centers (SA luminescence) during deformation recrystallization with an increase in the dissolved oxygen concentration is presented. Restriction of the spectral range of the appearance of self-activated luminescence at shallow levels—“edge” luminescence—is established. The nature of the emission bands in the wavelength ranges of 336–350 and 364–390 nm is established. These results refine the energy model of ZnS(O) crystals and can be useful in the case of the practical use of their structure-sensitive properties.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ferroelectrics of homogeneously deformed rare-earth garnet crystals, excited by elastic wave propagation

The effect of deformation on the electric properties in rare-earth garnet compounds is elucidated. It is shown that inhomogeneous deformation causes the emergence of electric polarization in garnet crystals on account of nonequivalent low-symmetry sites of rare-earth ions in the cubic structure of these crystals, whose symmetry of the environment has no inversion center. The polarization of a rare-earth ion subsystem in garnet crystals is studied upon the elastic wave propagation therein.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of phase transitions on the kinetic parameters of polytetrafluoroethylene deformation

The effect of solid-state phase transitions on the kinetic parameters of creep deformation in polytetrafluoroethylene has been studied by differential scanning calorimetry and a laser-interferometric creep rate meter. It has been shown that the deformation activation volumes and the elementary phase transition volume differ from each other by more than an order of magnitude. The crystalline component of this polymer becomes a liquid-crystal phase coexisting with an amorphous phase.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structural–Temporal Peculiarities of Dynamic Deformation of Nanostructured and Nanoscaled Metals

The evolution of a structural–temporal integral criterion of yielding is reported for the description of the dynamic deformation of metals. The values of characteristic relaxation times, considered as the constants of the material, are shown to be suitable for the description of dynamic effects upon the nanomaterial deformation in a wide range of loading rates. Three various ways of the determination of characteristic relaxation time of nanomaterials are discussed. The behavior of the ultimate stress in the range of pulse duration from one and two points of change in the dominant mechanism of rate sensitivity is interpreted in the context of integral criterion of yielding.

77 NANOSCIENCE AND NANOTECHNOLOGY↗