Search NASA⌕ Search

SEARCH · Search NASA

Results for “delta method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Heat capacities, order-disorder transitions, and thermodynamic properties of rare-earth orthoferrites and rare-earth iron garnets

Rare-earth orthoferrites, RFeO{sub 3}, and rare-earth iron garnets (RIGs) R{sub 3}Fe{sub 5}O{sub 12} (R=rare-earth elements) were prepared by citrate-nitrate gel combustion method and characterized by X-ray diffraction method. Isobaric molar heat capacities of these oxides were determined by using differential scanning calorimetry from 130 to 860 K. Order-disorder transition temperatures were determined from the heat capacity measurements. The Neel temperatures (T{sub N}) due to antiferromagentic to paramagnetic transitions in orthoferrites and the Curie temperatures (T{sub C}) due to ferrimagnetic to paramagnetic transitions in garnets were determined from the heat capacity data. Both T{sub N} and T{sub C} systematically decrease with increasing atomic number of R across the series. Lattice, electronic and magnetic contributions to the total heat capacity were calculated. Debye temperatures as a function of absolute temperature were calculated for these compounds. Thermodynamic functions like C{sub p,m}{sup o}, S{sub m}{sup o}, H{sup o}, G{sup o}, (H{sub T}{sup o}-H{sub 0}{sup o}), (H{sub T}{sup o}-H{sub 298.15K}{sup o}), -(G{sub T}{sup o}-H{sub 298.15K}{sup o})/T, {delta}{sub f}H{sub m}{sup o}, and {delta}{sub f}G{sub m}{sup o} have been generated for the compounds RFeO{sub 3}(s) and R{sub 3}Fe{sub 5}O{sub 12}(s) based on the experimental data obtained in this study and the available data in the literature. - Graphical abstract: Plot of molar heat capacities (C{sub p,m}{sup o}) of R{sub 3}Fe{sub 5}O{sub 12}(s) (R=Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb and Lu) against temperature (T). The inset shows the magnified portion of the heat capacity plot near the transition region indicating nearly same values of Curie temperatures for different R{sub 3}Fe{sub 5}O{sub 12}(s)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Image Guidance Based on Prostate Position for Prostate Cancer Proton Therapy

Purpose: To determine the target coverage for proton therapy with and without image guidance and daily prebeam reorientation. Methods and Materials: A total of 207 prostate positions were analyzed for 9 prostate cancer patients treated using our low-risk prostate proton therapy protocol (University of Florida Proton Therapy Institute 001). The planning target volume was defined as the prostate plus a 5-mm axial and 8-mm superoinferior extension. The prostate was repositioned using 5- and 10-mm shifts (anteriorly, inferiorly, posteriorly, and superiorly) and for Points A-D using a combination of 10-mm multidimensional movements (anteriorly or inferiorly; posteriorly or superiorly; and left or right). The beams were then realigned using the new prostate position. The prescription dose was 78 Gray equivalent (GE) to 95% of the planning target volume. Results: For small movements in the anterior, inferior, and posterior directions within the planning target volume ({<=}5 mm), treatment realignment demonstrated small, but significant, improvements in the clinical target volume (CTV) coverage to the prescribed dose (78 GE). The anterior and posterior shifts also significantly increased the minimal CTV dose ({delta} +1.59 GE). For prostate 10-mm movements in the inferior, posterior, and superior directions, the beam realignment produced larger and significant improvements for both the CTV V{sub 78} ({delta} +6.4%) and the CTV minimal dose ({delta} +8.22 GE). For the compounded 10-mm multidimensional shifts, realignment significantly improved the CTV V{sub 78} ({delta} +11.8%) and CTV minimal dose ({delta} +23.6 GE). After realignment, the CTV minimal dose was >76.6 GE (>98%) for all points (A-D). Conclusion: Proton beam realignment after target shift will enhance CTV coverage for different prostate positions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Steps toward determination of the size and structure of the broad-line region in active galactic nuclei. 5: Variability of the ultraviolet continuum and emission lines of NGC 3783

We report on the results of intensive ultraviolet spectral monitoring of the Seyfert 1 galaxy NGC 3783. The nucleus of NGC 3783 was observed with the International Ultraviolet Explorer satellite on a regular basis for a total of 7 months, once every 4 days for the first 172 days and once every other day for the final 50 days. Significant variability was observed in both continuum and emission-line fluxes. The light curves for the continuum fluxes exhibited two well-defined local minima or 'dips,' the first lasting is less than or approximately 20 days and the second is less than or approximately 4 days, with additional episodes of relatively rapid flickering of approximately the same amplitude. As in the case of NGC 5548 (the only other Seyfert galaxy that has been the subject of such an intensive, sustained monitoring effort), the largest continuum variations were seen at the shortest wavelengths, so that the continuum became 'harder' when brighter. The variations in the continuum occurred simultaneously at all wavelengths (delta(t) is less than 2 days). Generally, the amplitude of variability of the emission lines was lower than (or comparable to) that of the continuum. Apart from Mg II (which varied little) and N V (which is relatively weak and badly blended with Ly(alpha), the light curves of the emission lines are very similar to the continuum light curves, in each case with a small systematic delay or 'lag.' As for NGC 5548, the highest ionization lines seem to respond with shorter lags than the lower ionization lines. The lags found for NGC 3783 are considerably shorter than those obtained for NGC 5548, with values of (formally) approximately 0 days for He II + O III), and approximately 4 days for Ly(alpha) and C IV. The data further suggest lags of approximately 4 days for Si IV + O IV) and 8-30 days for Si III + C III). Mg II lagged the 1460 A continuum by approximately 9 days, although this result depends on the method of measuring the line flux and may in fact be due to variability of the underlying Fe II lines. Correlation analysis further shows that the power density spectrum contains substantial unresolved power over timescales of is less than or approximately 2 days, and that the character of the continuum variability may change with time.

Reichert, G. A.↗

Kinetics of cycle length dependence of ventricular repolarization: effect of autonomic blockade

INTRODUCTION: Beat-to-beat adaptation of ventricular repolarization duration to cardiac cycle length and autonomic activity has not been previously characterized in the spontaneously beating human heart. METHODS AND RESULTS: The ECG of 14 healthy subjects was recorded from the supine and upright positions. Autonomic blockade was accomplished by atropine and propranolol. RR and RT intervals were measured by a computer algorithm, and the impulse response (h) from RR to RT computed. In the supine position the maximal adjustment of the RT interval occurred in the first beat following a change in cycle length (hpeak = 17.8 +/- 1.6 msec/sec), but continued to be detectable for 3.8 seconds (2.9-4.7 sec). Propranolol attenuated the peak impulse response to 15.8 +/- 4.0 msec/sec (P = NS). In the standing position the peak impulse response was increased to 25.2 +/- 5.0 msec/sec (P = 0.004 vs supine), and the impulse response duration (hdur) shortened to 1.4 seconds (1.3-1.6). This was reversed by beta blockade (hpeak = 10.7 +/- 3.6 [P = 0.005 vs standing]; hdur = 5.5 sec [4.8-6.1]). Parasympathetic and combined autonomic blockade resulted in too little residual heart rate variability to estimate the impulse response accurately. The slope of the regression of delta RT and delta RR in the supine position was 0.0177 +/- 0.0016, which was closely correlated with the peak impulse response (r = 0.91). CONCLUSIONS: System identification techniques can assist in characterizing the cycle dependence of ventricular repolarization and may provide new insights into conditions associated with abnormal repolarization.

Clinical Trial↗

Synergistic use of Knudsen effusion quadrupole mass spectrometry, solid-state galvanic cell and differential scanning calorimetry for thermodynamic studies on lithium aluminates

Three ternary oxides LiAl{sub 5}O{sub 8}(s), LiAlO{sub 2}(s) and Li{sub 5}AlO{sub 4}(s) in the system Li-Al-O were prepared by solid-state reaction route and characterized by X-ray powder diffraction method. Equilibrium partial pressure of CO{sub 2}(g) over the three-phase mixtures {l_brace}LiAl{sub 5}O{sub 8}(s)+Li{sub 2}CO{sub 3}(s)+5Al{sub 2}O{sub 3}(s){r_brace}, {l_brace}LiAl{sub 5}O{sub 8}(s)+5LiAlO{sub 2}(s)+2Li{sub 2}CO{sub 3}(s){r_brace} and {l_brace}LiAlO{sub 2}(s)+Li{sub 5}AlO{sub 4}(s)+2Li{sub 2}CO{sub 3}(s){r_brace} were measured using Knudsen effusion quadrupole mass spectrometry (KEQMS). Solid-state galvanic cell technique based on calcium fluoride electrolyte was used to determine the standard molar Gibbs energies of formations of these aluminates. The standard molar Gibbs energies of formation of these three aluminates calculated from KEQMS and galvanic cell measurements were in good agreement. Heat capacities of individual ternary oxides were measured from 127 to 868 K using differential scanning calorimetry. Thermodynamic tables representing the values of {delta}{sub f}H{sup 0}(298.15 K), S{sup 0}(298.15 K) S{sup 0}(T), C{sub p}{sup 0}(T), H{sup 0}(T), {l_brace}H{sup 0}(T)-H{sup 0}(298.15 K){r_brace}, G{sup 0}(T), {delta}{sub f}H{sup 0}(T), {delta}{sub f}G{sup 0}(T) and free energy function (fef) were constructed using second law analysis and FACTSAGE thermo-chemical database software. - Graphical abstract: Comparison of {delta}{sub f}G{sub m}{sup 0} of ternary oxides determined from KEQMS and solid-state galvanic cell techniques. (O) KEQMS, (9632;) solid-state galvanic cell and solid line: combined fit of both the experimental data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A theoretical study on phase-contrast mammography with Thomson-scattering x-ray sources

Purpose: The x-ray transmitted beam from any material/tissue depends on the complex refractive index (n=1-{delta}+i{beta}), where {delta} is responsible for the phase shift and {beta} is for the beam attenuation. Although for human tissues, the {delta} cross section is about 1000 times greater than the {beta} ones in the x-ray energy range from 10 to 150 keV, the gain in breast tumor visualization of phase-contrast mammography (PCM) with respect to absorption contact imaging (AI) is limited by the maximum dose that can be delivered to the patient. Moreover, in-line PC imaging (PCI) is the simplest experimental mode among all available x-ray PCI techniques since no optics are needed. The latter is a fundamental requirement in order to transfer the results of laboratory research into hospitals. Alternative to synchrotron radiation sources, the implementation of relativistic Thomson-scattering (TS) x-ray sources is particularly suitable for hospital use because of their high peak brightness within a relatively compact and affordable system. In this work, the possibility to realize PCM using a TS source in a hospital environment is studied, accounting for the effect of a finite deliverable dose on the PC visibility enhancement with respect to AI. Methods: The contrast-to-noise ratio of tumor-tissue lesions in PCM has been studied on the bases of a recent theoretical model, describing image contrast formation by means of both wave-optical theory and the mutual coherence formalism. The latter is used to describe the evolution, during wave propagation, of the coherence of the wave field emitted by a TS source. The contrast-to-noise ratio for both PCI and AI has been analyzed in terms of tumor size, beam energy, detector, and source distances, studying optimal conditions for performing PCM. Regarding other relevant factors which could influence ''tumor'' visibility, the authors have assumed simplified conditions such as a spherical shape description of the tumor inclusion, a constant surrounding background, ideal conditions for the calculus of the contrast-to-noise ratio. Results: The results show the possibility to enhance with PCI the signal-to-noise ratio for features in the submillimeter scale. This finding could give PCM a great advantage with respect to AI, opening the possibility to decrease the number of wrong diagnoses before histological exams. The results agree with experimental evidences obtained by Dreossi et al.[D. Dreossi et al., ''The mammography project at the SYRMEP beamline,'' Eur. J. Radiol. 68, S58-S62 (2008)] with real PCM using synchrotron radiation. Conclusions: The challenging characteristics of TS sources, suitable for PCM, should be fluxes of at least 10{sup 11} photons/s emitted by very small sources of about 10 {mu}m, together with moderate energy spreads (less than 10%) in order to realize both sufficient spatial coherence and enough fluence on the patient, collecting images in reasonable exposure times. These fluxes will be achieved by next generation TS sources which are already under development.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-CAMPUS-T-05: Validation of High-Resolution 3D Patient QA for Proton Pencil Beam Scanning and IMPT by Polymer Gel Dosimetry

Purpose: Validation of high-resolution 3D patient QA for proton pencil beam scanning and IMPT by polymer gel dosimetry. Methods: Four BANG3Pro polymer gel dosimeters (manufactured by MGS Research Inc, Madison, CT) were used for patient QA at the Robert's Proton Therapy Center (RPTC, Philadelphia, PA). All dosimeters were sealed in identical thin-wall Pyrex glass spheres. Each dosimeter contained a set of markers for 3D registration purposes. The dosimeters were mounted in a consistent and reproducible manner using a custom build holder. Two proton pencil beam scanning plans were designed using Varian Eclipse™ treatment planning system: 1) A two-field intensity modulated proton therapy (IMPT) plan and 2) one single field uniform dose (SFUD) plan. The IMPT fields were evaluated as a composite plan and individual fields, the SFUD plan was delivered as a single field plan.Laser CT scanning was performed using the manufacturer's OCTOPUS-IQ axial transmission laser CT scanner using a 1 mm slice thickness. 3D registration, analysis, and OD/cm to absorbed dose calibrations were perfomed using DICOM RT-Dose and CT files, and software developed by the manufacturer. 3D delta index, a metric equivalent to the gamma tool, was used for dose comparison. Results: Very good agreement with single IMPT fields and with SFUD was obtained. Composite IMPT fields had a less satisfactory agreement. The single fields had 3D delta index passing rates (3% dose difference, 3 mm DTA) of 98.98% and 94.91%. The composite 3D delta index passing rate was 80.80%. The SFUD passing rate was 93.77%. Required shifts of the dose distributions were less than 4 mm. Conclusion: A formulation of the BANG3Pro polymer gel dosimeter, suitable for 3D QA of proton patient plans is established and validated. Likewise, the mailed QA analysis service provided by the manufacturer is a practical option when required resources are unavailable. We fully disclose that the subject of this research regards a production of MGS Research, Inc.

60 APPLIED LIFE SCIENCES↗

Nonnegative tensor factorization for contaminant source identification

Unsupervised Machine Learning (ML) is becoming increasingly popular for solving various types of data analytics problems including feature extraction, blind source separation, exploratory analyses, model diagnostics, etc. In this work, we have developed a new unsupervised ML method based on Nonnegative Tensor Factorization (NTF) for identification of the original groundwater types (including contaminant sources) present in geochemical mixtures observed in an aquifer. Frequently, groundwater types with different geochemical signatures are related to different background and/or contamination sources. The characterization of groundwater mixing processes is a challenging but very important task critical for any environmental management project aiming to characterize the fate and transport of contaminants in the subsurface and perform contaminant remediation. This task typically requires solving complex inverse models representing groundwater flow and geochemical transport in the aquifer, where the inverse analysis accounts for available site data. Usually, the model is calibrated against the available data characterizing the spatial and temporal distribution of the observed geochemical types. Numerous different geochemical constituents and processes may need to be simulated in these models which further complicates the analyses. Additionally, the application of inverse methods may introduce biases in the analyses through the assumptions made in the model development process. Here, we substitute the model inversion with unsupervised ML analysis. The ML analysis does not make any assumptions about underlying physical and geochemical processes occurring in the aquifer. Our ML methodology, called NTFk, is capable of identifying (1) the unknown number of groundwater types (contaminant sources) present in the aquifer, (2) the original geochemical concentrations (signatures) of these groundwater types and (3) spatial and temporal dynamics in the mixing of these groundwater types. These results are obtained only from the measured geochemical data without any additional site information. In general, the NTFk methodology allows for interpretation of large high-dimensional datasets representing diverse spatial and temporal components such as state variables and velocities. NTFk has been tested on synthetic and real-world site three-dimensional datasets. Finally, the NTFk algorithm is designed to work with geochemical data represented in the form of concentrations, ratios (of two constituents; for example, isotope ratios), and delta notations (standard normalized stable isotope ratios).

58 GEOSCIENCES↗

Technique for Solving Electrically Small to Large Structures for Broadband Applications

Fast iterative algorithms are often used for solving Method of Moments (MoM) systems, having a large number of unknowns, to determine current distribution and other parameters. The most commonly used fast methods include the fast multipole method (FMM), the precorrected fast Fourier transform (PFFT), and low-rank QR compression methods. These methods reduce the O(N) memory and time requirements to O(N log N) by compressing the dense MoM system so as to exploit the physics of Green s Function interactions. FFT-based techniques for solving such problems are efficient for spacefilling and uniform structures, but their performance substantially degrades for non-uniformly distributed structures due to the inherent need to employ a uniform global grid. FMM or QR techniques are better suited than FFT techniques; however, neither the FMM nor the QR technique can be used at all frequencies. This method has been developed to efficiently solve for a desired parameter of a system or device that can include both electrically large FMM elements, and electrically small QR elements. The system or device is set up as an oct-tree structure that can include regions of both the FMM type and the QR type. The system is enclosed with a cube at a 0- th level, splitting the cube at the 0-th level into eight child cubes. This forms cubes at a 1st level, recursively repeating the splitting process for cubes at successive levels until a desired number of levels is created. For each cube that is thus formed, neighbor lists and interaction lists are maintained. An iterative solver is then used to determine a first matrix vector product for any electrically large elements as well as a second matrix vector product for any electrically small elements that are included in the structure. These matrix vector products for the electrically large and small elements are combined, and a net delta for a combination of the matrix vector products is determined. The iteration continues until a net delta is obtained that is within the predefined limits. The matrix vector products that were last obtained are used to solve for the desired parameter. The solution for the desired parameter is then presented to a user in a tangible form; for example, on a display.

Jandhyala, Vikram↗

Incorporating Love- and Rayleigh-wave magnitudes, unequal earthquake and explosion variance assumptions and interstation complexity for improved event screening

Our objective is to improve seismic event screening using the properties of surface waves, We are accomplishing this through (1) the development of a Love-wave magnitude formula that is complementary to the Russell (2006) formula for Rayleigh waves and (2) quantifying differences in complexities and magnitude variances for earthquake and explosion-generated surface waves. We have applied the M{sub s} (VMAX) analysis (Bonner et al., 2006) using both Love and Rayleigh waves to events in the Middle East and Korean Peninsula, For the Middle East dataset consisting of approximately 100 events, the Love M{sub s} (VMAX) is greater than the Rayleigh M{sub s} (VMAX) estimated for individual stations for the majority of the events and azimuths, with the exception of the measurements for the smaller events from European stations to the northeast. It is unclear whether these smaller events suffer from magnitude bias for the Love waves or whether the paths, which include the Caspian and Mediterranean, have variable attenuation for Love and Rayleigh waves. For the Korean Peninsula, we have estimated Rayleigh- and Love-wave magnitudes for 31 earthquakes and two nuclear explosions, including the 25 May 2009 event. For 25 of the earthquakes, the network-averaged Love-wave magnitude is larger than the Rayleigh-wave estimate. For the 2009 nuclear explosion, the Love-wave M{sub s} (VMAX) was 3.1 while the Rayleigh-wave magnitude was 3.6. We are also utilizing the potential of observed variances in M{sub s} estimates that differ significantly in earthquake and explosion populations. We have considered two possible methods for incorporating unequal variances into the discrimination problem and compared the performance of various approaches on a population of 73 western United States earthquakes and 131 Nevada Test Site explosions. The approach proposes replacing the M{sub s} component by M{sub s} + a* {sigma}, where {sigma} denotes the interstation standard deviation obtained from the stations in the sample that produced the M{sub s} value. We replace the usual linear discriminant a* M{sub s}+b*{sub m{sub b}} with a* M{sub s}+b*{sub m{sub b}} + C*{sigma}. In the second approach, we estimate the optimum hybrid linear-quadratic discriminant function resulting from the unequal variance assumption. We observed slight improvement for the discriminant functions resulting from the theoretical interpretations of the unequal variance function. We have also studied the complexity of the ''magnitude spectra'' at each station. Our hypothesis is that explosion spectra should have fewer focal mechanism-produced complexities in the magnitude spectra than earthquakes. We have developed an intrastation ''complexity'' metric {Delta}M{sub s}, where {Delta}M{sub s} = M{sub s}(i)-M{sub s}(i+1) at periods, i, which are between 9 and 25 seconds. The complexity by itself has discriminating power but does not add substantially to the conditional hybrid discriminant that incorporates the differing spreads of the earthquake and explosion standard deviations.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Laboratory tests on mercury emission monitoring with resonating gold-coated silicon cantilevers

To measure extremely low concentrations of mercury vapor in gases as encountered in flue gases of coal-fired power plants, accurate and reliable online and/or portable mercury detection systems are needed. As discussed in this communication, resonating silicon-based cantilevers coated with thin films of gold change their resonant frequency when exposed to mercury vapors and could serve as the basis for such sensing devices. Two different types of commercial AFM cantilevers, which differed by physical dimensions and surface finish, were coated with a 10 nm film of gold and were tested in streams of argon containing mercury. The argon flow rates ranged from 5.7 to 57.4 mL/min, carrying mercury vapors at concentrations between 37 and 700 {mu}g/m{sup 3}. The results show that smaller cantilevers (about 140 {mu}m x 40 {mu}m x 4 {mu}m) with a resonant frequency of 270-275 kHz were sensitive to less than 10 picograms of mercury, whereas larger cantilevers (about 245 {mu}m x 50 {mu} x 7 {mu}m) with a resonant frequency of 155-165 kHz have a sensitivity about 10 times lower. The results indicate that the kinetics of mercury capture by the gold coating follows a simple power law-correlation with the mass change ({delta}m) being proportional to t{sup n}, where t is the capture time and n depends strongly on the concentration of mercury in the gas. It is also demonstrated that the mercury can be stripped off the gold coating by heating to 350{sup o}C, which would allow the cantilevers to be regenerated and reused. 20 refs., 8 figs., 2 tabs.

01 COAL, LIGNITE, AND PEAT↗

University of Lodz an electron spectrometer—A new conversion-electron spectrometer for “in-beam” measurements

The designed and constructed at the University of Lodz an electron spectrometer is devoted to “in-beam” measurements. The apparatus is characterized by high efficiency up to 9%, good energy resolution (FWHM = 5 keV at 482 keV) and, what is very important good suppression of delta electrons, positrons, and photons emitted by the targets. This achievement was obtained using a combination of magnetic field in two different layouts: perpendicular and parallel to the axis of the spectrometer being orthogonal to the beamline. The conversion-electron spectrometer coupled to the EAGLE array was successfully tested in an “in-beam” measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tailoring a low-molecular weight protein tyrosine phosphatase into an efficient reporting protein

Fusion reporter methods are important tools for biology and biotechnology. An ideal reporter protein in a fusion system should have little effects on its fusion partner and provide an easy and accurate readout. Therefore, a small monomeric protein with high activity for detection assays often has advantages as a reporter protein. For this purpose, we have tailored the human B-form low-molecular-weight phosphotyrosyl phosphatase (HPTP-B) to increase its general applicability as a potent reporter protein. With the aim to eliminate interference from cysteine residues in the native HPTP-B, combined with a systematic survey of N- and C-terminal truncated variants, a series of cysteine to serine mutations were introduced, which allowed isolation of an engineered soluble protein with suitable biophysical properties. When we deleted both the first six residues and the last two residues, we still obtained a soluble mutant protein with correct folding and similar activity with wild-type protein. This mutant with two cysteine to serine mutations, HPTP-B{sup N{sub {Delta}}6-C{sub {Delta}}2-C90S-C109S}, has good potential as an optimal reporter.

60 APPLIED LIFE SCIENCES↗

Modeling treatment couches in the Pinnacle treatment planning system: Especially important for arc therapy

This study is to demonstrate the importance and a method of properly modeling the treatment couch for dose calculation in patient treatment using arc therapy. The 2 treatment couch tops—Aktina AK550 and Elekta iBEAM evo—of Elekta LINACs were scanned using Philips Brilliance Big Bore CT Simulator. Various parts of the couch tops were contoured, and their densities were measured and recorded on the Pinnacle treatment planning system (TPS) using the established computed tomography density table. These contours were saved as organ models to be placed beneath the patient during planning. Relative attenuation measurements were performed following procedures outlined by TG-176 as well as absolute dose comparison of static fields of 10 × 10 cm{sup 2} that were delivered through the couch tops with that calculated in the TPS with the couch models. A total of 10 random arc therapy treatment plans (5 volumetric-modulated arc therapy [VMAT] and 5 stereotactic body radiation therapy [SBRT]), using 24 beams, were selected for this study. All selected plans were calculated with and without couch modeling. Each beam was evaluated using the Delta{sup 4} dosimetry system (Delta{sup 4}). The Student t-test was used to determine statistical significance. Independent reviews were exploited as per the Imaging and Radiation Oncology Core head and neck credentialing phantom. The selected plans were calculated on the actual patient anatomies with and without couch modeling to determine potential clinical effects. Large relative beam attenuations were noted dependent on which part of the couch top beams were passing through. Substantial improvements were also noted for static fields both calculated with the TPS and delivered physically when the couch models were included in the calculation. A statistically significant increase in agreement was noted for dose difference, distance to agreement, and γ-analysis with the Delta{sup 4} on VMAT and SBRT plans. A credentialing review showed improvement in treatment delivery after couch modeling with both thermoluminescent dosimeter doses and film analysis. Furthermore, analysis of treatment plans with and without using the couch model showed a statistically significant reduction in planning target volume coverage and increase in skin dose. In conclusion, ignoring the treatment couch, a common practice when generating a patient treatment plan, can overestimate the dose delivered especially for arc therapy. This work shows that explicitly modeling the couch during planning can meaningfully improve the agreement between calculated and measured dose distributions. Because of this project, we have implemented the couch models clinically across all treatment plans.

61 RADIATION PROTECTION AND DOSIMETRY↗

Study On Electron Collisions With Zn-like W Ion

The present work gives new refined results for electron impact excitation rates and collision strengths for transitions of type [Ar]3d{sup 10}4snl->[Ar]3d{sup 10}4sn';l', n, n' = 4,5, and {delta}J = 0,l in Zn-like W ion. We have examined the position and widths of the resonant states of type ls{sup 2}2s2p{sup 6}3s{sup 2}3p{sup 6}3d{sup 10}4s{sup 2}nl. Autoionizing states can radically alter the low temperature behavior of collision rates, and are a major contributor to opacity. Preliminary results for Auger rates are presented. Hartree-Fock calculations have been carried out followed by a configuration interaction (CI) in intermediate coupling using the suite of Cowan's codes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validation of the Mars 2020 Fault Protection Design: Navigating the Infinity of the Off-Nominal

On July 30th 2020, the Mars 2020 mission successfully launched out of Cape Canaveral, Florida, passed through the Earth’s shadow, and began its short cruise to Mars. Less than seven months later, the Perseverance rover touched down safely in Jezero Crater to begin its ambitious mission that includes looking for signs of ancient life and collecting samples for future return to Earth. Getting to the successful landing, or “Tango Delta Nominal,” could not have been achieved without also considering the off-nominal. One of the teams supporting this ambitious mission is the fault protection (FP) team. This team is tasked with assessing the various failures, or faults, that could prevent mission success and with ensuring that the autonomous behaviors built into the software and hardware can detect faults and recover the vehicle to a safe state. As part of its charter, the FP team designed a test campaign to provide confidence in the system’s robustness to off-nominal scenarios across all of Mars 2020’s mission phases. The greatest challenge associated with designing such a validation campaign was reducing the infinite number of anomalous scenarios into a finite test suite. In addition, the tests needed to be executed efficiently in order to utilize the team’s limited test venue access, but still needed to maintain a level of rigor that guaranteed confidence in the test outcomes. Given that each test scenario generated massive amounts of data, the team also developed methods for quickly ascertaining whether the autonomous fault protection behaviors maintained vehicle safety in the presence of an anomaly. This paper summarizes the processes that the Mars 2020 fault protection team employed to execute its off-nominal validation campaign. It captures both the methods of generating a suite of off-nominal tests, as well as reducing it to a subset that can be realistically executed within schedule and resource constraints. It also describes the various processes and philosophies that the team utilized to execute the tests efficiently, including creating a standardized procedure template, keeping the test cases modular so that they could be easily interchanged, and capturing common fault injections in a change-controlled database. Finally, it will describe the tools and processes for assessing the test data, focusing in particular on a tool that evaluated vehicle state using “secondary” sources of data to validate that the software had truly configured the spacecraft to the expected safe state.

Morantz, Chaz↗

Rovibrationally selected ion-molecule collision study using the molecular beam vacuum ultraviolet laser pulsed field ionization-photoion method: Charge transfer reaction of N{sub 2}{sup +}(X {sup 2}{Sigma}{sub g}{sup +}; v{sup +}= 0-2; N{sup +}= 0-9) + Ar

We have developed an ion-molecule reaction apparatus for state-selected absolute total cross section measurements by implementing a high-resolution molecular beam vacuum ultraviolet (VUV) laser pulsed field ionization-photoion (PFI-PI) ion source to a double-quadrupole double-octopole ion-guide mass spectrometer. Using the total cross section measurement of the state-selected N{sub 2}{sup +}(v{sup +}, N{sup +}) + Ar charge transfer (CT) reaction as an example, we describe in detail the design of the VUV laser PFI-PI ion source used, which has made possible the preparation of reactant N{sub 2}{sup +}(X {sup 2}{Sigma}{sub g}{sup +}, v{sup +}= 0-2, N{sup +}= 0-9) PFI-PIs with high quantum state purity, high intensity, and high kinetic energy resolution. The PFI-PIs and prompt ions produced in the ion source are shown to have different kinetic energies, allowing the clean rejection of prompt ions from the PFI-PI beam by applying a retarding potential barrier upstream of the PFI-PI source. By optimizing the width and amplitude of the pulsed electric fields employed to the VUV-PFI-PI source, we show that the reactant N{sub 2}{sup +} PFI-PI beam can be formed with a laboratory kinetic energy resolution of {Delta}E{sub lab}={+-} 50 meV. As a result, the total cross section measurement can be conducted at center-of-mass kinetic energies (E{sub cm}'s) down to thermal energies. Absolute total rovibrationally selected cross sections {sigma}(v{sup +}= 0-2, N{sup +}= 0-9) for the N{sub 2}{sup +}(X {sup 2}{Sigma}{sub g}{sup +}; v{sup +}= 0-2, N{sup +}= 0-9) + Ar CT reaction have been measured in the E{sub cm} range of 0.04-10.0 eV, revealing strong vibrational enhancements and E{sub cm}-dependencies of {sigma}(v{sup +}= 0-2, N{sup +}= 0-9). The thermochemical threshold at E{sub cm}= 0.179 eV for the formation of Ar{sup +} from N{sub 2}{sup +}(X; v{sup +}= 0, N{sup +}) + Ar was observed by the measured {sigma}(v{sup +}= 0), confirming the narrow {Delta}E{sub cm} spread achieved in the present study. The {sigma}(v{sup +}= 0-2; N{sup +}) values obtained here are compared with previous experimental and theoretical results. The theoretical predictions calculated based on the Landau-Zener-Stueckelberg formulism are found to be in fair agreement with the present measured {sigma}(v{sup +}= 1 or 2; N{sup +}). Taking into account of the experimental uncertainties, the measured {sigma}(v{sup +}= 1 or 2, N{sup +}) for N{sup +}= 0-9 at E{sub cm}= 0.04-10.0 eV are found to be independent of N{sup +}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NUCLEAR CONSTRAINTS ON PROPERTIES OF NEUTRON STAR CRUSTS

The transition density {rho} {sub t} and pressure P{sub t} at the inner edge separating the liquid core from the solid crust of neutron stars are systematically studied using a modified Gogny (MDI) and 51 popular Skyrme interactions within well established dynamical and thermodynamical methods. First of all, it is shown that the widely used parabolic approximation to the full equation of state (EOS) of isospin asymmetric nuclear matter may lead to huge errors in estimating the transition density and pressure, especially for stiffer symmetry energy functionals E {sub sym}({rho}), compared to calculations using the full EOS within both the dynamical and thermodynamical methods mainly because of the energy curvatures involved. Thus, fine details of the EOS of asymmetric nuclear matter are important for locating accurately the inner edge of the neutron star crust. Second, the transition density and pressure decrease roughly linearly with increasing slope parameter L of E {sub sym}({rho}) at normal nuclear matter density using the full EOS within both the dynamical and thermodynamical methods. It is also shown that the thickness, fractional mass, and moment of inertia of the neutron star crust are all very sensitive to the parameter L through the transition density {rho} {sub t} whether one uses the full EOS or its parabolic approximation. Moreover, it is shown that E {sub sym}({rho}) constrained in the same subsaturation density range as the neutron star crust by the isospin diffusion data in heavy-ion collisions at intermediate energies limits the transition density and pressure to 0.040 fm{sup -3} {<=}{rho} {sub t} {<=} 0.065 fm{sup -3} and 0.01 MeV fm{sup -3} {<=}P{sub t} {<=} 0.26 MeV fm{sup -3}, respectively. These constrained values for the transition density and pressure are significantly lower than their fiducial values currently used in the literature. Furthermore, the mass-radius relation and several other properties closely related to the neutron star crust are studied by using the MDI interaction. It is found that the newly constrained {rho} {sub t} and P{sub t} together with the earlier estimate of {delta}I/I>0.014 for the crustal fraction of the moment of inertia of the Vela pulsar impose a more stringent constraint of R {>=} 4.7 + 4.0M/M {sub sun} km for the radius R and mass M of neutron stars compared to previous studies in the literature.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗