Search NASA⌕ Search

SEARCH · Search NASA

Results for “dynamic loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Effect of high current electron beam in a 30 MeV radio frequency linac for neutron-time-of-flight applications

A high power pulsed radio frequency electron linac is designed by BARC, India to accelerate 30 MeV, 10 A, 10 ns beam for neutron-time-of-flight applications. It will be used as a neutron generator and will produce ∼10{sup 12}–10{sup 13} n/s. It is essential to reduce the beam instability caused by space charge effect and the beam cavity interaction. In this paper, the wakefield losses in the accelerating section due to bunch of RMS (Root mean square) length 2 mm (at the gun exit) is analysed. Loss and kick factors are numerically calculated using CST wakefield solver. Both the longitudinal and transverse wake potentials are incorporated in beam dynamics code ELEGANT to find the transverse emittance growth of the beam propagating through the linac. Beam loading effect is examined by means of numerical computation carried out in ASTRA code. Beam break up start current has been estimated at the end of the linac which arises due to deflecting modes excited by the high current beam. At the end, transverse beam dynamics of such high current beam has been analysed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Implementation of Parallel Dynamic Simulation on Shared-Memory vs. Distributed-Memory Environments

Power system dynamic simulation computes the system response to a sequence of large disturbance, such as sudden changes in generation or load, or a network short circuit followed by protective branch switching operation. It consists of a large set of differential and algebraic equations, which is computational intensive and challenging to solve using single-processor based dynamic simulation solution. High-performance computing (HPC) based parallel computing is a very promising technology to speed up the computation and facilitate the simulation process. This paper presents two different parallel implementations of power grid dynamic simulation using Open Multi-processing (OpenMP) on shared-memory platform, and Message Passing Interface (MPI) on distributed-memory clusters, respectively. The difference of the parallel simulation algorithms and architectures of the two HPC technologies are illustrated, and their performances for running parallel dynamic simulation are compared and demonstrated.

dynamic simulation↗

Integrating Solar PV in Utility System Operations

This study develops a systematic framework for estimating the increase in operating costs due to uncertainty and variability in renewable resources, uses the framework to quantify the integration costs associated with sub-hourly solar power variability and uncertainty, and shows how changes in system operations may affect these costs. Toward this end, we present a statistical method for estimating the required balancing reserves to maintain system reliability along with a model for commitment and dispatch of the portfolio of thermal and renewable resources at different stages of system operations. We estimate the costs of sub-hourly solar variability, short-term forecast errors, and day-ahead (DA) forecast errors as the difference in production costs between a case with “realistic” PV (i.e., subhourly solar variability and uncertainty are fully included in the modeling) and a case with “well behaved” PV (i.e., PV is assumed to have no sub-hourly variability and can be perfectly forecasted). In addition, we highlight current practices that allow utilities to compensate for the issues encountered at the sub-hourly time frame with increased levels of PV penetration. In this analysis we use the analytical framework to simulate utility operations with increasing deployment of PV in a case study of Arizona Public Service Company (APS), a utility in the southwestern United States. In our analysis, we focus on three processes that are important in understanding the management of PV variability and uncertainty in power system operations. First, we represent the decisions made the day before the operating day through a DA commitment model that relies on imperfect DA forecasts of load and wind as well as PV generation. Second, we represent the decisions made by schedulers in the operating day through hour-ahead (HA) scheduling. Peaking units can be committed or decommitted in the HA schedules and online units can be redispatched using forecasts that are improved relative to DA forecasts, but still imperfect. Finally, we represent decisions within the operating hour by schedulers and transmission system operators as real-time (RT) balancing. We simulate the DA and HA scheduling processes with a detailed unit-commitment (UC) and economic dispatch (ED) optimization model. This model creates a least-cost dispatch and commitment plan for the conventional generating units using forecasts and reserve requirements as inputs. We consider only the generation units and load of the utility in this analysis; we do not consider opportunities to trade power with neighboring utilities. We also do not consider provision of reserves from renewables or from demand-side options. We estimate dynamic reserve requirements in order to meet reliability requirements in the RT operations, considering the uncertainty and variability in load, solar PV, and wind resources. Balancing reserve requirements are based on the 2.5th and 97.5th percentile of 1-min deviations from the HA schedule in a previous year. We then simulate RT deployment of balancing reserves using a separate minute-by-minute simulation of deviations from the HA schedules in the operating year. In the simulations we assume that balancing reserves can be fully deployed in 10 min. The minute-by-minute deviations account for HA forecasting errors and the actual variability of the load, wind, and solar generation. Using these minute-by-minute deviations and deployment of balancing reserves, we evaluate the impact of PV on system reliability through the calculation of the standard reliability metric called Control Performance Standard 2 (CPS2). Broadly speaking, the CPS2 score measures the percentage of 10-min periods in which a balancing area is able to balance supply and demand within a specific threshold. Compliance with the North American Electric Reliability Corporation (NERC) reliability standards requires that the CPS2 score must exceed 90% (i.e., the balancing area must maintain adequate balance for 90% of the 10-min periods). The combination of representing DA forecast errors in the DA commitments, using 1-min PV data to simulate RT balancing, and estimates of reliability performance through the CPS2 metric, all factors that are important to operating systems with increasing amounts of PV, makes this study unique in its scope.

14 SOLAR ENERGY↗

Dynamic fatigue measurement of human erythrocytes using dielectrophoresis

Erythrocytes must undergo severe deformation to pass through narrow capillaries and submicronic splenic slits for several hundred thousand times in their normal lifespan. Studies of erythrocyte biomechanics have been mainly focused on cell deformability and rheology measured from a single application of stress and mostly under a static or quasi-static state using classical biomechanical techniques, such as optical tweezers and micropipette aspiration. Dynamic behavior of erythrocytes in response to cyclic stresses that contributes to the membrane failure in blood circulation is not fully understood. This article presents a new experimental method for dynamic fatigue analysis of erythrocytes, using amplitude modulated electrokinetic force field in a microfluidic platform. Here, we demonstrate the capability of this new technique using a low cycle fatigue analysis of normal human erythrocytes and ATP-depleted erythrocytes. Cyclic tensile stresses are generated to induce repeated uniaxial stretching and extensional recovery of single erythrocytes. Results of morphological and biomechanical parameters of individually tracked erythrocytes show strong correlations with the number of the loading cycles. Under a same strength of electric field, after 180 stress cycles, for normal erythrocytes, maximum stretch ratio decreases from 3.80 to 2.86, characteristic time of cellular extensional recovery increases from 0.16 s to 0.37 s, membrane shear viscosity increases from 1.0 (µN/m) s to 1.6 (µN/m) s. Membrane deformation in a small number of erythrocytes becomes irreversible after large deformation for about 200 cyclic loads. ATP-depleted cells show similar trends in decreased deformation and increased characteristic time with the loading cycles. Lastly, these results show proof of concept of the new microfluidics technique for dynamic fatigue analysis of human erythrocytes.

60 APPLIED LIFE SCIENCES↗

Stress Induced Phase Transformation in Nanocrystalline UO2

We report a stress-induced phase transformation in stoichiometric UO2 from fluorite to a-PbO2 structure using molecular dynamics (MD) simulations and density functional theory (DFT) calculations. MD simulations, performed on nanocrystalline microstructure under constant-stress tensile loading conditions, reveal a heterogeneous nucleation of a- PbO2 phase at the grain boundaries followed by the growth of this phase towards the interior of the grain. The DFT calculations confirm the existence of the a-PbO2 structure, showing that it is energetically favored under tensile loading conditions.

36 MATERIALS SCIENCE↗

Multi-scale computational analysis of unidirectional carbon fiber reinforced polymer composites under various loading conditions

In this study, a multi-scale computational analysis based on representative volume element (RVE) modeling and molecular dynamics (MD) simulations is developed to investigate the microscopic failure mechanisms of unidirectional (UD) carbon fiber reinforced polymer (CFRP) composites. The average properties of the 200-nm thickness interphase region between fiber and matrix are characterized through MD simulations and an analytical gradient model. The results demonstrate that the interphase region has higher Young’s modulus and strength, compared to the bulk matrix. This stiffened interphase region influences the composite response significantly. Specifically, the traditional two-phase model with zero-thickness interface fails to capture the stress-strain behavior compared to the experimental data. However, by adding the interphase region to a modified RVE model, the accuracy of simulation results will be improved significantly. Furthermore, a coupled experimental-computational micromechanics approach is adopted to calibrate and validate the cohesive parameters of the interface. By including the cohesive interface, our modified RVE model accurately captures the failure strength of the composites. Finally, different failure mechanisms for specimens are investigated using our multi-scale computational framework. In conclusion, the results show that the failure modes of UD CFRP composites are very complex and multiple failure mechanisms co-exist depending on the loading conditions, agreeing well with our experimental analyses.

36 MATERIALS SCIENCE↗

Inertia estimation for power grids: A review of methods, challenges, and future prospects

The electric power grid is undergoing a significant transformation, shifting from traditional synchronous generators to inverter-based resources (IBRs) such as solar photovoltaics, wind turbines, and energy storage systems. This evolution leads to a reduction in system inertia, a critical attribute for maintaining frequency stability in response to disturbances. Consequently, the ability to monitor and estimate system inertia has become increasingly essential. This paper provides a comprehensive review of existing inertia estimation methodologies, analyzing them from multiple perspectives, including the types of data utilized, underlying estimation principles, operational modes, and system-wide applicability. A comparative summary table is included to distill commonalities and key characteristics across various studies. In addition, the paper examines practical implementations of inertia estimation across several major power systems worldwide, including the U.S. interconnections, the Nordic power system, and the U.K. grid. Key challenges are identified, particularly in estimating contributions from virtual inertia sources and load-induced inertia in increasingly converter-dominated networks. To address these emerging challenges, the paper proposes an integrated framework for real-time inertia estimation and monitoring. This framework encompasses critical components such as data acquisition, inertia estimation from both synchronous and non-synchronous sources, load-induced effects, optimization techniques, forecasting, and virtual inertia scheduling. Collectively, these elements enable dynamic, system-wide monitoring and adaptive control of grid inertia.

Inertia estimation↗

Design Considerations for RDamage Load Evolution or "Why We Built What We Built"

The RDamage series of ten experiments is part of a long-term collaboration with RFNC/VNIIEF in pulsed power technology. These experiments use a cylindrical configuration to study spallation damage, which allows for a natural recollection of the damaged material under proper driving conditions and post-shot collection of the damaged target material for subsequent metallographic analysis. Dynamic in-situ experimental velocimetry diagnostics are also employed. LANL is responsible for the design of the experimental load and velocimetry system. VNIIEF is responsible for the design and construction of the driving explosive magnetic generator. In the RDamage-0, -1 and -2 experiments, data was collected about failure initiation of a well-characterized material (aluminum) in a cylindrical geometry. The RDamage-3, -4 and -5 experiments produced data on the behavior of material recollected after damage from pressures in the damage initiation regime. Data on the behavior of material recollected after complete failure was collected in the RDamage-6, -7, -8 and -9 experiments. This presentation shows the design choices behind the evolution of the load assembly through the experimental series.

36 MATERIALS SCIENCE↗

Enhanced accuracy through ensembling of randomly initialized auto-regressive models for dynamical systems

Computational mechanics simulations using traditional finite element methods (FEM) require prohibitively expensive computational resources for real-time engineering applications, design optimization, and digital twin implementations. While machine learning (ML) surrogate models offer significant computational speedups, autoregressive ML models for time-dependent mechanical systems suffer from error accumulation that compromises long-term prediction reliability - a critical concern for engineering applications where accuracy over extended time horizons is essential for safety and performance assessments. Here, we propose a deep ensemble framework specifically designed to address this challenge in computational mechanics applications, where multiple ML surrogate models with random weight initializations are trained in parallel and their predictions aggregated during inference. This approach leverages statistical diversity to maximize information gain from a fixed set of training data and to mitigate error propagation, while maintaining the computational efficiency that makes ML surrogates attractive for engineering practice. We validate the framework on three representative problems spanning critical areas of computational mechanics: stress field evolution in heterogeneous microstructures under complex loading (relevant to advanced materials design and composite analysis), planetary-scale shallow water dynamics (applicable to environmental and geotechnical engineering), and Gray-Scott reaction-diffusion systems (relevant to mass transport and chemical process engineering). Across all test cases, the ensemble approach demonstrates consistent error reduction of 15-33% compared to individual models. The codes for this work are available on GitHub (https://github.com/Graham-Brady-Research-Group/AutoregressiveEnsemble_SpatioTemporal_Evolution).

autoregressive prediction↗

Dynamic induced softening in frictional granular materials investigated by discrete-element-method simulation

A granular system composed of frictional glass beads is simulated here using the discrete element method. The intergrain forces are based on the Hertz contact law in the normal direction with frictional tangential force. The damping due to collision is also accounted for. Systems are loaded at various stresses and their quasistatic elastic moduli are characterized. Each system is subjected to an extensive dynamic testing protocol by measuring the resonant response to a broad range of ac drive amplitudes and frequencies via a set of diagnostic strains. The system, linear at small ac drive amplitudes, has resonance frequencies that shift downward (i.e., modulus softening) with increased ac drive amplitude. Detailed testing shows that the slipping contact ratio does not contribute significantly to this dynamic modulus softening, but the coordination number is strongly correlated to this reduction. This suggests that the softening arises from the extended structural change via break and remake of contacts during the rearrangement of bead positions driven by the ac amplitude.

58 GEOSCIENCES↗

Dynamic modelling and control strategy of a temperature-driven metal hydride cooling system for buildings

A temperature-driven coupled metal hydride (MH) based thermal energy storage (TES) system can allow to shave and shift the peak energy demand in buildings. The high energy density and long-term (seasonal) energy storage capability are its major advantages over other energy storage methods. The dynamic nature of the MH operation, however, requires controlled hydrogen transfer between the coupled MHs at a rate needed to meet the building's transient load. While temperature-driven MH systems are studied in the literature, their application in buildings and control are scarcely reported. Here, this paper presents a control-based dynamic modeling of the temperature-driven coupled MH-TES system for building cooling applications. The dynamic model is developed in MATLAB(R) Simulink environment, considering the thermodynamic and kinetic behaviors of the MH systems. Based on a preliminary analysis of a property database of over 337 hydrides, we select around 1600 MH pairs suitable for building cooling applications. Each of these MH pairs is studied for their performance using the dynamic model, and among all, Zr 0.76 Ti 0.24 Ni 1.16 Mn 0.63 V 0.14 Fe 0.18 -Ti 0.85 Zr 0.15 Cr 1.2 Mn 0.8 MH pair showed fast dynamics along with high coefficient of performance (COP) of 0.71. A parametric investigation is performed on this MH pair to understand the effect of operating temperatures. Finally, three proportional-integral (PI) feedback controllers are investigated to regulate the temperature, pressure and mass exchange between the coupled MH pairs. The developed PI controller is sufficiently capable of rejecting the signal noise from the hydrogen flow and internal heat exchange processes with root mean square error of 5.78 W between reference and actual cooling load.

08 HYDROGEN↗

Power control system modification and simulation of CPR1000 - 181

Due to development of electric power system, the proportion of nuclear power and its needs for load follow operation have become large. Then there would be higher requirements to the power control ability of the nuclear power system. The axial power distribution may change a lot in the operation process and be affected by many factors. In particular, as the power change is performed within a load follow maneuver, several modifications occur in the core from a neutronic view point: the fuel and moderator temperature change, the xenon concentration and distribution are modified, the power distribution skewed axially, etc. These changes need to be adequately counterbalanced to keep both the core critical and the power distribution acceptable. The traditional approach in pressurized water reactors (PWRs) is compensating for the reactivity change due to the power variation by adjusting the soluble boron concentration and moving a limited number of control banks. However, dilution/boronation strategy becomes expensive for short time changes and leads to large volume of liquid effluent, so it is eager about a capability to perform load follow operation without changing soluble boron concentration. CPR1000, one of the main reactor types in China national development, is taken an example in this paper. It adopts a control method called Mode G, using G banks, N banks, R bank and soluble boron to perform the load follow control. According to the analysis of the physics and thermal principle, a two-node dynamic function model was built, putting the coupling coefficient and mutual influence into consideration. By the calculation of these transient parameter values which are acquired by the steady-state calculation of single channel, the core system model of CPR1000 is established. In order to carry out the load follow operation without the boron adjustment, named as BTP mode, the control banks were regrouped to control the average temperature by M banks and axial offset by AO bank. After that, the average temperature control system (M banks control system) and the axial offset control system (AO bank control system) are built. When the optimal control system is connected to the core model simulation platform, the BTP mode load follow operation of the modified CPR1000 is simulated in the end of the paper. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Verification and Validation of the New Dynamic Mooring Modules Available in FAST v8: Preprint

The open-source aero-hydro-servo-elastic wind turbine simulation software, FAST v8, was recently coupled to two newly developed mooring dynamics modules: MoorDyn and FEAMooring. MoorDyn is a lumped-mass-based mooring dynamics module developed by the University of Maine, and FEAMooring is a finite-element-based mooring dynamics module developed by Texas A&M University. This paper summarizes the work performed to verify and validate these modules against other mooring models and measured test data to assess their reliability and accuracy. The quality of the fairlead load predictions by the open-source mooring modules MoorDyn and FEAMooring appear to be largely equivalent to what is predicted by the commercial tool OrcaFlex. Both mooring dynamic model predictions agree well with the experimental data, considering the given limitations in the accuracy of the platform hydrodynamic load calculation and the quality of the measurement data.

17 WIND ENERGY↗

Development of a system for heating and cooling targets in laser-based dynamic compression experiments

The ability to study the temperature dependence of material properties for various microstructures under extreme loading conditions enables a greater understanding of a range of high pressure, high strain rate phenomena, extending from space and planetary science to fundamental material science. In this study, we describe an apparatus designed to pre-heat or pre-cool targets to temperatures ranging between80-800 K for laser-driven shock experiments, and we further review the implementation of such an apparatus in laser-shock experiments and comments on potential future capabilities.

36 MATERIALS SCIENCE↗

Ensuring Transient Stability With Guaranteed Region of Attraction in DC Microgrids

DC microgrids have promising applications in renewable integration due to their better energy efficiency when connecting DC components. However, they might be unstable since many loads in a DC microgrid are regulated as constant power loads (CPLs) that have a destabilizing negative impedance effect. As a result, the state trajectory displacement caused by abrupt load changes or contingencies can easily lead to instability. Many existing works have been devoted to studying the region of attraction (ROA) of a DC microgrid, in which the system is guaranteed to be asymptotically stable. Nevertheless, existing work either focuses on using numerical methods for ROA approximations that generally have no performance guarantees or cannot ensure a desired ROA for a general DC microgrid. To close this gap, this paper develops an innovative control synthesis algorithm to make a general DC microgrid have a theoretically guaranteed ROA, for example, to cover the entirety of its operating range regarding state trajectories. Here, we first study the nonlinear dynamics of a DC microgrid to derive a novel transient stability condition to rigorously certify whether a given operating range is a subset of the ROA; then, we formulate a control synthesis optimization problem to guarantee the condition’s satisfaction. This condition is a linear constraint, and the optimization problem resembles an optimal power flow problem and has a good computational behavior. Simulation case studies verify the validity of the proposed work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Extension of the Supercritical Carbon Dioxide Brayton Cycle to Low Reactor Power Operation: Investigations using the Coupled ANL Plant Dynamics Code-SAS4A/SASSYS-1 Liquid Metal Reactor Code System

Significant progress has been made on the development of a control strategy for the supercritical carbon dioxide (S-CO 2 ) Brayton cycle enabling removal of power from an autonomous load following Sodium-Cooled Fast Reactor (SFR) down to decay heat levels such that the S-CO 2 cycle can be used to cool the reactor until decay heat can be removed by the normal shutdown heat removal system or a passive decay heat removal system such as Direct Reactor Auxiliary Cooling System (DRACS) loops with DRACS in-vessel heat exchangers. This capability of the new control strategy eliminates the need for use of a separate shutdown heat removal system which might also use supercritical CO 2 . It has been found that this capability can be achieved by introducing a new control mechanism involving shaft speed control for the common shaft joining the turbine and two compressors following reduction of the load demand from the electrical grid to zero. Following disconnection of the generator from the electrical grid, heat is removed from the intermediate sodium circuit through the sodium-to-CO 2 heat exchanger, the turbine solely drives the two compressors, and heat is rejected from the cycle through the CO 2 -to-water cooler. To investigate the effectiveness of shaft speed control, calculations are carried out using the coupled Plant Dynamics Code-SAS4A/SASSYS-1 code for a linear load reduction transient for a 1000 MWt metallic-fueled SFR with autonomous load following. No deliberate motion of control rods or adjustment of sodium pump speeds is assumed to take place. It is assumed that the S-CO 2 turbomachinery shaft speed linearly decreases from 100 to 20% nominal following reduction of grid load to zero. The reactor power is calculated to autonomously decrease down to 3% nominal providing a lengthy window in time for the switchover to the normal shutdown heat removal system or for a passive decay heat removal system to become effective. However, the calculations reveal that the compressor conditions are calculated to approach surge such that the need for a surge control system for each compressor is identified. Thus, it is demonstrated that the S-CO 2 cycle can operate in the initial decay heat removal mode even with autonomous reactor control. Because external power is not needed to drive the compressors, the results show that the S-CO 2 cycle can be used for initial decay heat removal for a lengthy interval in time in the absence of any off-site electrical power. The turbine provides sufficient power to drive the compressors. Combined with autonomous reactor control, this represents a significant safety advantage of the S-CO 2 cycle by maintaining removal of the reactor power until the core decay heat falls to levels well below those for which the passive decay heat removal system is designed. The new control strategy is an alternative to a split-shaft layout involving separate power and compressor turbines which had previously been identified as a promising approach enabling heat removal from a SFR at low power levels. The current results indicate that the split-shaft configuration does not provide any significant benefits for the S-CO 2 cycle over the current single-shaft layout with shaft speed control. It has been demonstrated that when connected to the grid the single-shaft cycle can effectively follow the load over the entire range. No compressor speed variation is needed while power is delivered to the grid. When the system is disconnected from the grid, the shaft speed can be changed as effectively as it would be with the split-shaft arrangement. In the split-shaft configuration, zero generator power means disconnection of the power turbine, such that the resulting system will be almost identical to the single-shaft arrangement. Without this advantage of the split-shaft configuration, the economic benefits of the single-shaft arrangement, provided by just one turbine and lower losses at the design point, are more important to the overall cycle performance. Therefore, the single-shaft configuration shall be retained as the reference arrangement for S-CO 2 cycle power converter preconceptual designs. Improvements to the ANL Plant Dynamics Code have been carried out. The major code improvement is the introduction of a restart capability which simplifies investigation of control strategies for very long transients. Another code modification is transfer of the entire code to a new Intel Fortran complier; the execution of the code using the new compiler was verified by demonstrating that the same results are obtained as when the previous Compaq Visual Fortran compiler was used.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Assessment of Model-Based Schemes for Accelerating Optimization by RAVEN

Nuclear-Renewable Hybrid Energy Systems (N-R HES) combine different energy technologies in a synergistic way with the objective of achieving a more economical energy production. In this report the particular hybrid system dealt with includes a PWR nuclear reactor, the associated Rankine-based energy conversion cycle (Balance of Plant, BOP), an Industrial Process (IP) for hydrogen production, a gas turbine (Second Energy Source, SES), and a battery (Energy Storage, ES). The RAVEN-based HYBRID framework is used to find the optimal installed capacity and the optimal economical dispatch of each component of the N-R HES. HYBRID solves the coupled capacity planning-economic and dispatch optimization problem with the objective of minimizing the Levelized Cost of Electricity (LCOE). In the optimization of the power dispatch strategy, the HYBRID framework takes into account the time-dependent dynamics of each subsystem by including a Dymola object-oriented model of the process dynamics. To ease the computational burden of the optimization process, an initial guess for the dispatch optimization problem is provided by a preconditioner. The solution guess is calculated by means of a least-marginal cost approach which applies the same criterion behind the screening curve method. Though this algorithm allows evaluating an economically adapted generation mix for a target load duration curve within a few seconds, it neglects the constraints due to the single component dynamics, and it is not able to adequately represent the ES. An improved treatment of the pre-conditioner problem was addressed by introducing a Monte Carlo based optimization algorithm. The new approach takes into account limits on power rates for the system subcomponents, which was not previously done. Additionally, this new Monte-Carlo based preconditioner addresses the problem with the ES component through improved modeling of that component. The new algorithm has been implemented in the HYBRID framework and tested to assess its performance. The results obtained with the new Monte Carlobased preconditioner were benchmarked against those obtained through the reference deterministic approach. The comparison shows that the Monte-Carlo based approach provides improved solution accuracy to the power dispatch optimization problem. Also in this report, the treatment of the penalty function on LCOE is discussed, and an improved penalty function for missed demand is suggested and tested.

Maronati, Giovanni↗