Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

An ultrafast nanotip electron gun triggered by grating-coupled surface plasmons

We demonstrate multiphoton photoelectron emission from gold nanotips induced by nanofocusing surface plasmons, resonantly excited on the tip shaft by a grating coupler. The tip is integrated into an electron gun assembly, which facilitates control over the spatial emission sites and allows us to disentangle direct grating emission from plasmon-triggered apex emission. The nanoscale source size of this electron gun concept enables highly coherent electron pulses with applications in ultrafast electron imaging and diffraction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Energy response characterization of current-mode MeV Cherenkov aerogel detectors

Current-mode Cherenkov aerogel detectors have been used to measure time resolved spectra of MeV radiographic x-ray sources and have been considered to replace gas Cherenkov systems. The simulations of the Cherenkov response of aerogel detectors have uncertainties in how to model the complex structure of aerogels. Data from three sites—the Idaho electron beam, the Los Alamos Site electron beam and microtron sources at Los Alamos—have been used to calibrate the relative energy response of 15 aerogels, varying in density from 10 to 430 mg/cm 3 , from incident electrons with energies from 1 to 12 MeV. Detector simulations need to introduce density variation in the aerogels to match the collected data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Positive ion composition and derived particle heating in the lower auroral ionosphere

Two E11a rocket flights in salvo B (launched on November 16, 1980) and A2 (launched on November 30, 1980), which provide positive ion composition, total and partial ion density, and electron density in the altitude range 60-170 km above Kiruna under conditions of moderate and strong magnetic disturbance, are examined. It is shown that the ionization sources are predominantly precipitating electrons in salvo B and precipitating protons in salvo A2. Under winter-time auroral conditions the characteristics of the positive ion composition are large NO(+)/O2(+) density ratios, with maximum values of 20 at 118 km in salvo B and 100 at 100 km in salvo A2, respectively. The transition from NO(+) to proton hydrates is found at an altitude of 79 km in salvo B and 76 km in salvo A2. The calculated O(+) and N(+) densities are in good agreement with model calculations and from these calculations it is concluded that 28(+) is mainly N2(+) above 110 km in salvo B and above 105 km in salvo A2, and Si(+) below these altitudes. By altitude integration of the ion-electron pair production, the energy flux of precipitating particles is found to have values of 0.85 mW/sq m and 1.0 mW/sq m in salvoes B and A2, respectively.

Kopp, E.↗

Cryogenic Considerations for Superconducting Magnet Design for the Material Plasma Exposure eXperiment

In order to determine long term performance of plasma facing components such as diverters and first walls for fusion devices, next generation plasma generators are needed. A Material Plasma Exposure eXperiment (MPEX) has been proposed to address this need through the generation of plasmas in front of the target with electron temperatures of 1-15 eV and electron densities of 1020 to 1021 m-3. Heat fluxes on target diverters could reach 20 MW/m2. In order generate this plasma, a unique radio frequency helicon source and heating of electrons and ions through Electron Bernstein Wave (EBW) and Ion Cyclotron Resonance Heating (ICRH) has been proposed. MPEX requires a series of magnets with non-uniform central fields up to 2 T over a 5m length in the heating and transport region and 1 T uniform central field over a 1-m length on a diameter of 1.3 m. Given the field requirements, superconducting magnets are under consideration for MPEX. In order to determine the best construction method for the magnets, the cryogenic refrigeration has been analyzed with respect to cooldown and operational performance criteria for open-cycle and closed-cycle systems, capital and operating costs of these system, and maturity of supporting technology such as cryocoolers. These systems will be compared within the context of commercially available magnet constructions to determine the most economical method for MPEX operation. The current state of the MPEX magnet design including details on possible superconducting magnet configurations will be presented.

Duckworth, Robert C↗

X-Ray Comb Generation from Nuclear-Resonance-Stabilized X-Ray Free-Electron Laser Oscillator for Fundamental Physics and Precision Metrology

An x-ray free-electron laser oscillator (XFELO) is a next-generation x-ray source, similar to free-electron laser oscillators at VUV and longer wavelengths but using crystals as high-reflectivity x-ray mirrors. Each output pulse from an XFELO is fully coherent with high spectral purity. The temporal coherence length can further be increased drastically, from picoseconds to microseconds or even longer, by phase-locking successive XFELO output pulses, using the narrow nuclear resonance lines of nuclei such as Fe-57 as a reference. We show that the phase fluctuation due to the seismic activities is controllable and that due to spontaneous emission is small. The fluctuation of electron-bunch spacing contributes mainly to the envelope fluctuation but not to the phase fluctuation. By counting the number of standing-wave maxima formed by the output of the nuclear-resonance-stabilized (NRS) XFELO over an optically known length, the wavelength of the nuclear resonance can be accurately measured, possibly leading to a new length or frequency standard at x-ray wavelengths. A NRS-XFELO will be an ideal source for experimental x-ray quantum optics as well as other fundamental physics. The technique can be refined for other, narrower resonances such as Ta-181 or Sc-45.

Adams, B. W.↗

Deep Space Systems Technology Program Future Deliveries

NASA is in a period of frequent launches of low cost deep space missions with challenging performance needs. The modest budgets of these missions make it impossible for each to develop its own technology, therefore, efficient and effective development and insertion of technology for these missions must be approached at a higher level than has been done in the past. The Deep Space Systems Technology Program (DSST), often referred to as X2000, has been formed to address this need. The program is divided into a series of "Deliveries" that develop and demonstrate a set of spacecraft system capabilities with broad applicability for use by multiple missions. The First Delivery Project, to be completed in 2001, will provide a one MRAD-tolerant flight computer, power switching electronics, efficient radioisotope power source, and a transponder with services at 8.4 GHz and 32 GHz bands. Plans call for a Second Delivery in late 2003 to enable complete deep space systems in the 10 to 50 kg class, and a Third Delivery built around Systems on a Chip (extreme levels of electronic and microsystems integration) around 2006. Formulation of Future Deliveries (past the First Delivery) is ongoing and includes plans for such developments as highly miniaturized digital/analog/power electronics, optical communications, multifunctional structures, miniature lightweight propulsion, advanced thermal control techniques, highly efficient radioisotope power sources, and a unified flight ground software architecture to support the needs of future highly intelligent space systems. All developments are targeted at broad applicability and reuse, and will be commercialized within the US.

Salvo, Christopher G.↗

Microstructural analysis of recycled concrete using X-ray microtomography

This paper reports an investigation of the recycled concrete (RC) microstructure using synchrotron microtomography (μCT) at the Advanced Light Source combined with Scanning Electron Microscopy analysis. The study evaluated the influence of 50% of recycled concrete aggregate (RCA) and its water absorption compensation on the RC microstructure. The following variables were studied: a) the compressive strength of the original concrete used to obtain the RCA (40 and 80 MPa) and b) the initial moisture condition of the RCA (Saturated Surface Dry and Oven Dry). The microtomographic images showed the mixtures cast with RCA in the dry condition developed an evident macropore network surrounding the RCA particle that was not observed in the mixtures using RCA in the SSD condition. SEM images confirmed the initial findings from μCT and showed that the thickness of the interfacial transition zone in RC is in the same order of magnitude as the reference concrete.

36 MATERIALS SCIENCE↗

Effect of THz-bandwidth incoherent laser radiation on bulk damage in potassium dihydrogen phosphate crystals

Abstract The laser-damage performance characteristics of potassium dihydrogen phosphate (KDP) samples under exposure to a distinctive broadband incoherent laser pulse are investigated. A laser system providing such pulses is intended to explore improved energy-coupling efficiency on the target in direct-drive inertial confinement fusion experiments and provides incoherent bandwidths as large as 10 THz in a nanosecond pulse. A consequence of this bandwidth is very rapid fluctuations in intensity capable of reaching maxima much larger than the average intensity within the pulse. A custom damage-test station has been built to perform measurements with broadband incoherent pulses in order to determine what effect these fast and high-intensity oscillations have on laser damage. A set of experiments under different bandwidth and beam configurations shows the effect to be minimal when probing bulk damage in KDP. Modeling indicates this behavior is supported by long electron-relaxation times compared to the source-field fluctuations, following excitation of individual electrons in the conduction band. The results help better understand the laser-induced–damage mechanisms in KDP, and its ability to operate in broadband temporally incoherent high-energy lasers that may be particularly suitable for future laser-fusion energy systems.

36 MATERIALS SCIENCE↗

Beam-plasma interactions as a heat source in the magnetosphere

Strong electron precipitation fluxes are frequently accompanied by strong downward heat conduction fluxes, deduced from simultaneous high and low altitude electron temperature measurements. It is shown that the heat input due to beam-plasma interactions is of the correct order of magnitude to sustain the observed heat flux.

Fontheim, E. G.↗

Transverse diffusion of electrons in a magnetoplasma

Plasma density and temperature profiles were measured for plasma electrons which were generated by a plasma source and ionization from a 1 kev electron beam. Electron plasma parameters were measured with a cylindrical Langmuir probe which was moved perpendicular to the axis of the beam and field. Electron densities decreased exponentially from the beam center and the decay constant varied with magnetic field in accordance with the Bohm theory of cross field diffusion. This enhanced diffusion effect due to instabilities generated by the electron beam is orders of magnitude larger than that due to particle collisions.

Mcintyre, Bernard↗

High-sensitivity electronic Stark spectrometer featuring a laser-driven light source

We report developmental details of a high-sensitivity Stark absorption spectrometer featuring a laser-driven light source. The light source exhibits intensity fluctuations of ~0.3% over timescales ranging from 1 min to 12 h, minimal drift (≤0.1%/h), and very little 1/f noise at frequencies greater than 200 Hz, which are comparable to or better than an arc-driven light source. Additional features of the spectrometer include balanced detection with multiplex sampling, which yielded lower noise in A, and constant wavelength or wavenumber (energy) spectral bandpass modes. We achieve noise amplitudes of ~7 × 10 –4 and ~6 × 10 –6 in measurements of single A and ΔA spectra (with 92 data points) taking ~7 and ~19 min, respectively.

47 OTHER INSTRUMENTATION↗

Slot-Antenna/Permanent-Magnet Device for Generating Plasma

A device that includes a rectangular-waveguide/slot-antenna structure and permanent magnets has been devised as a means of generating a substantially uniform plasma over a relatively large area, using relatively low input power and a low gas flow rate. The device utilizes electron cyclotron resonance (ECR) excited by microwave power to efficiently generate plasma in a manner that is completely electrodeless in the sense that, in principle, there is no electrical contact between the plasma and the antenna. Plasmas generated by devices like this one are suitable for use as sources of ions and/or electrons for diverse material-processing applications (e.g., etching or deposition) and for ion thrusters. The absence of plasma/electrode contact essentially prevents plasma-induced erosion of the antenna, thereby also helping to minimize contamination of the plasma and of objects exposed to the plasma. Consequently, the operational lifetime of the rectangular-waveguide/ slot-antenna structure is long and the lifetime of the plasma source is limited by the lifetime of the associated charged-particle-extraction grid (if used) or the lifetime of the microwave power source. The device includes a series of matched radiating slot pairs that are distributed along the length of a plasma-source discharge chamber (see figure). This arrangement enables the production of plasma in a distributed fashion, thereby giving rise to a uniform plasma profile. A uniform plasma profile is necessary for uniformity in any electron- or ion-extraction electrostatic optics. The slotted configuration of the waveguide/ antenna structure makes the device scalable to larger areas and higher powers. All that is needed for scaling up is the attachment of additional matched radiating slots along the length of the discharge chamber. If it is desired to make the power per slot remain constant in scaling up, then the input microwave power must be increased accordingly. Unlike in prior ECR microwave plasma-generating devices, there is no need for an insulating window on the antenna. Such windows are sources of contamination and gradually become ineffective as they become coated with erosion products over time. These characteristics relegate prior ECR microwave plasma-generating devices to non-ion beam, non-deposition plasma applications. In contrast, the lack of need for an insulating window in the present device makes it possible to use the device in both ion-beam (including deposition) and electron-beam applications. The device is designed so that ECR takes place above each slot and the gradient of the magnetic field at each slot is enough to prevent backflow of plasma.

Foster, John E.↗

Spatial resolution of imaging plate with flash X-rays and its utilization for radiography

A flash X-ray source developed using pulsed electron accelerator with electron energy range of 400keV to 1030keV and a field emission cathode is characterized using X-ray imaging plates. Spatial resolution of the imaging system is measured using edge spread function fitted to data obtained from radiograph of Pb step wedge. A spatial resolution of 150±6 µm is obtained. The X-ray beam size is controlled by the anode-cathode configuration. Optimum source size of ∼13±2 mm diameter covering an area with intensity of ∼27000 PSL/mm{sup 2} is obtained on the imaging plate kept at a distance of ∼200 mm from the tip of the anode. It is used for recording radiographs of objects like satellite cable cutter, aero-engine turbine blade and variety of pyro-devices used in aerospace industry.

07 ISOTOPE AND RADIATION SOURCES↗

CHARACTERIZATION OF RADIATION DAMAGES TO POSITRON SOURCE MATERIALS

The secondary beam production target at future positron sources at the Continuous Electron Beam Accelerator Facility (CEBAF), the International Linear Collider (ILC) or the Future Circular Collider (FCC), features unprecedented mechanical and thermal stresses which may compromise sustainable and reliable operation. Candidate materials are required to possess high melting temperature together with excellent thermal conductivity, elasticity and radiation hardness properties. In order to substantiate the material choice for the CEBAF and ILC positron sources, the response of candidate materials such as titanium alloys, tungsten, and tantalum to electron beam irradiation was experimentally investigated. CEBAF and ILC expected operating conditions were mimicked using the 3.5 MeV electron beam of the MAMI facility injector. The material degradations were precisely analyzed via high energy X-ray diffraction at the HEMS beamline operated by the Helmholtz-Zentrum Hereon at the PETRA III synchrotron facility. This work reports the results of these measurements and their interpretation.

Lengler, T.↗

Hydrodynamic model for expansion and collisional relaxation of x-ray laser-excited multi-component nanoplasma

The irradiation of an atomic cluster with a femtosecond x-ray free-electron laser pulse results in a nanoplasma formation. This typically occurs within a few hundred femtoseconds. By this time the x-ray pulse is over, and the direct photoinduced processes no longer contributing. All created electrons within the nanoplasma are thermalized. The nanoplasma thus formed is a mixture of atoms, electrons, and ions of various charges. While expanding, it is undergoing electron impact ionization and three-body recombination. Below we present a hydrodynamic model to describe the dynamics of such multi-component nanoplasmas. The model equations are derived by taking the moments of the corresponding Boltzmann kinetic equations. We include the equations obtained, together with the source terms due to electron impact ionization and three-body recombination, in our hydrodynamic solver. Model predictions for a test case, expanding spherical Ar nanoplasma, are obtained. With this model, we complete the two-step approach to simulate x-ray created nanoplasmas, enabling computationally efficient simulations of their picosecond dynamics. Moreover, the hydrodynamic framework including collisional processes can be easily extended for other source terms and then applied to follow relaxation of any finite non-isothermal multi-component nanoplasma with its components relaxed into local thermodynamic equilibrium.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Size dependent polaronic conduction in hematite

Lithium Ion Batteries have been attracted as the major renewable energy source for all portable electronic devices because of its advantages like superior energy density, high theoretical capacity, high specific energy, stable cycling and less memory effects. Recently, α-Fe{sub 2}O{sub 3} has been considered as a potential anode material due to high specific capacity, low cost, high abundance and environmental benignity. We have synthesized α-Fe{sub 2}O{sub 3} with various sizes by using the ball milling and sol-gel procedure. Here, we report the dc conductivity measurement for the crystallite size ranging from 15 nm to 50 nm. It has been observed that the enhancement in the polaronic conductivity nearly two orders in magnitude while reducing the crystallite size from bulk into nano scale level. The enhancement in the conductivity is due to the augmented to compressive strain developed in the material which leads to pronounced decrease in the hopping length of polarons. Thus, nanocrystaline α-Fe{sub 2}O{sub 3} may be a better alternative anode material for lithium ion batteries than earlier reported systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Physical and technical basis of Materials Plasma Exposure eXperiment from modeling and Proto-MPEX results *

Abstract The Materials Plasma Exposure eXperiment (MPEX) is a steady-state linear plasma device that will address plasma-material interaction (PMI) science and enable testing of fusion reactor-relevant divertor plasma-facing materials. The MPEX source concept consists of a helicon plasma source to generate the plasma, electron cyclotron heating (ECH) for electron heating, and ion cyclotron heating (ICH) for ion heating. The MPEX source plasma is then transported axially to the PMI material target region to test material samples in fusion reactor-relevant divertor conditions. This paper will summarize the physical and technical basis of MPEX. The paper will first define the MPEX parameters and scenarios at the target relevant to PMI science for various fusion reactor-relevant divertor conditions and show plasma transport modeling results to set the MPEX source parameters. Recent experimental and modeling results from Proto-MPEX, a short-pulse experiment to develop the plasma production, heating, and transport physics for MPEX, will be shown. From these results, it will be shown that MPEX can reach its desired scenarios. The MPEX physical and technical basis will also determine important functional requirements for magnetic field, radiofrequency (RF) power, RF frequency, and neutral pressure in the helicon, ECH, ICH, and PMI regions that are required to achieve the desired MPEX scenarios. The necessity for key in-vessel components such as skimmers, limiters, and microwave absorbers will also be highlighted.

Lau, C. (ORCID:0000000285765867)↗