Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Technology Solutions Case Study: Air Leakage and Air Transfer Between Garage and Living Space, Waldorf, Maryland

In this project, Building Science Corporation worked with production homebuilder K. Hovnanian to evaluate air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multipoint fan pressurization tests and additional zone pressure diagnostic testing measured the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

air leakage↗

Assessment of defense-related uranium mines in the United States and other US DOE office of legacy management domestic and international uranium initiatives - 15335

US DOE's Office of Legacy Management (LM) has taken several initiatives to improve domestic uranium mining and milling operations in the United States and to contribute to the management of legacy uranium mining and milling sites around the world. Initiatives include completing the 2014 Report to Congress on Defense-Related Uranium Mines, managing the Title X Uranium and Thorium Program with the Office of Environmental Management, and assisting IAEA with uranium issues in member state countries. The 2014 Report to Congress identified abandoned uranium mines (AUMs) in the United States that provided uranium ore to the US Atomic Energy Commission (AEC) between 1947 and 1970. The report identified AUM locations, reclamation/remediation status, radiological risks and other hazards, costs for reclamation and remediation, and potential prioritization schemes for mine cleanup. To develop reclamation and remediation cleanup cost estimates and assess risks, AUMs were grouped into six categories by tons of uranium ore produced, ranging from Small (less than 91 metric tons [100 tons]) to Very Large (greater than 453,900 metric tons [500,000 tons]). Radiological risk was calculated using the RESRAD computer code for five exposure scenarios: offsite resident, onsite resident, occasional visitor, recreational visitor, and mine reclamation worker. Results indicate that 69 percent of the AUMs are in Colorado and Utah and 23 percent are in Arizona, Wyoming, and New Mexico; and that the majority of the AUMs (68 percent) were considered Small or Small/Medium production mines, producing less than 908 metric tons (1,000 tons) of uranium ore. Although New Mexico has fewer AUMs (247) than the other states in the Colorado Plateau region, AUMs in that state (primarily those in the Grants Mineral Belt) produced 45 percent of the 79.5 million tons of AEC-purchased uranium ore. About 50 percent of the AUMs are on public land managed by the US Bureau of Land Management; 435 AUMs are on the Navajo Nation. Risk estimates for the onsite resident scenario (plausible on tribal and non-federal land) could result in an incremental cancer risk greater than 10{sup -4}. Radon inhalation was the dominant contributor to radiological risk for the five exposure scenarios evaluated. Different state and federal agencies are conducting cleanup of some AUMs under various remedial and legal authorities. Activities constituting mine 'reclamation' may reduce radiological risks to humans to acceptable levels for many mines on federal public lands if the occasional visitor and recreational visitor exposure scenarios are assumed. Addressing physical hazards (e.g., open shafts) at mines where conditions could cause serious injuries is typically a priority of public land management agencies. At locations where mine-related groundwater contamination occurs, it is a significant contributor to cleanup costs. However, most Small and Small/Medium AUMs were likely developed above the water table, and some wet mines are located in areas where groundwater has high, naturally occurring levels of the same constituents (including radioactive elements) that are typically associated with uranium mines. LM is also administering, with the US DOE Office of Environmental Management, the Title X program, which was developed by Congress to reimburse private companies (i.e., those that held active operating licenses prior to 1978) for a portion of their reclamation costs for mill sites that processed ore sold to AEC. LM recently updated the program guidance document and established internal protocols for annually auditing companies. LM is assisting IAEA on two different initiatives: assisting developing countries with training on the basic steps to take to perform reclamation of uranium mines, and developing technical guidance and case studies related to safety and environmental assessments and post-closure management of uranium legacy sites as part of the IAEA Regulatory Supervision of Legacy Sites initiative. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cybersecurity Assessments on Emulated DER Communication Networks

An increasing number of public utility commissions are adopting Distributed Energy Resource (DER) interconnection standards which require photovoltaic (PV) inverters, energy storage systems, and other DER to include interoperable grid-support functionality. The recently updated national standard, IEEE 1547-2018, requires all DER to include a Sun Spec Modbus, IEEE 2030.5, or IEEE 1815 communication interface in order to provide local and bulk power system services. Those communication protocols and associated information models will ensure system interoperability for PV and storage systems, but these new utility-to-DER communication networks must be deployed with sufficient cybersecurity to protect the U.S. power system and other critical infrastructure reliant on dependable power. Unlike bulk generators, DER are commonly connected to grid operators via public internet channels. These DER networks are exposed to a large attack surface that may leverage sophisticated techniques and infrastructure developed on IT systems, including remote exploits and distributed attacks. Although DER make up a growing portion of the national generation mix, they have limited processing capabilities and do not typically support modern security features such as encryption or authentication. In this work, Sandia National Laboratories constructed simulated DER communication net- works with a range of security features in order to study the security posture of different communication approaches. The experimental test environment was created in a Sandia-developed co-simulation platform, called SCEPTRE, which emulated Sun Spec-compliant DER equipment, the utility DER management system, communication network, and distribution power system. Adversary-based assessments were conducted and a quantitative scoring criteria was applied to evaluate the resilience of various architectures against cyber attacks and to measure the systemic impact during such attacks. The team found that network segmentation, encryption, and moving target defense improved the security of these networks and would be recommended for utility, aggregator, and local DER networks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Chemoradiation of Hepatic Malignancies: Prospective, Phase 1 Study of Full-Dose Capecitabine With Escalating Doses of Yttrium-90 Radioembolization

Purpose: Radiosensitizing chemotherapy improves the outcomes in comparison with radiation alone for gastrointestinal cancers. The delivery of radiation therapy with yttrium90 ({sup 90}Y) radioembolization, in combination with the radiosensitizing chemotherapeutic agent capecitabine, provides the opportunity to enhance the effects of radiation on hepatic malignancies. This phase 1 study sought to determine the maximum tolerated dose (MTD) of {sup 90}Y plus capecitabine in patients with cholangiocarcinoma or liver metastases confined to the liver. Methods and Materials: Patients were given initial treatment at full-dose capecitabine during days 1 to 14 of a 21-day cycle. At days 1 to 7 of the second cycle, whole-liver {sup 90}Y was given at the test dose, after which time capecitabine was continued. Dose-limiting toxicity (DLT) was determined 6 weeks after {sup 90}Y infusion. If a DLT was not observed, the {sup 90}Y dose was escalated. The planned dose cohorts were 110, 130, 150, and 170 Gy. The primary endpoint was to determine the MTD of {sup 90}Y with full-dose capecitabine. Results: Sixteen patients were treated according to the study protocol. Two patients experienced DLTs. Nine patients required capecitabine dose reduction as a result of toxicities attributable to capecitabine alone. The criteria for establishing {sup 90}Y MTD were not met, indicating an MTD of >170 Gy. Conclusion: The MTD of {sup 90}Y delivered in conjunction with capecitabine in the setting of intrahepatic cholangiocarcinoma or metastatic disease confined to the liver exceeds 170 Gy. This is the highest {sup 90}Y dose reported to date and has important implications on combined therapy with the radiosensitizing oral chemotherapeutic capecitabine. Further studies are under way.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-C-12A-07: Characterization of Longitudinal Reproducibility of Quantitative Diffusion Imaging Data Acquired with Four Different Protocols Using a Phantom

Purpose: To characterize and compare the longitudinal reproducibility of diffusion imaging data acquired with four different protocols using a phantom. Methods: The Diffusive Quantitative Imaging Phantom (DQIP) was constructed using fifteen cylindrical compartments within a larger compartment, filled with deionized water doped with CuSO4 and NaCl. The smaller compartments contained arrays of hexagonal or cylindrical glass capillaries of varying inner diameters, for differing restraint of water diffusion. The sensitivity of diffusion imaging metrics to signal-to-noise ratio (SNR) was probed by doping compartments with differing ratios of deuterium oxide to H2O. A cork phantom enclosure was constructed to increase thermal stability during scanning and a cork holder was made to reproduce scanner positioning. Four different protocols of DWI (diffusion weighted imaging) and DTI (Diffusion tensor imaging) imaging were assembled on a GE Excite HDx 3.0T MRI scanner to collect imaging data over 9-10 days. Data was processed with in-house software created in Matlab to obtain fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values. Results: All DTI and DWI sequences showed good longitudinal stability of mean FA and ADC values per compartment, exhibiting low standard deviation ∼9%. A t-test was performed to compare mean FA values from the DTI clinical protocol to those of the DTI special protocol, indicating significantly different values in the majority of compartments. ANOVA performed on ADC values for all DTI and DWI sequences also showed significantly different values in a majority of compartments. Conclusion: This work has the potential for quantifying systemic variations between diffusion imaging sequences from different platforms. Characterization of DWI and DTI performance were done over four sequences with predictable results. This data suggests that the DQIP phantom may be a reliable method of monitoring day-to-day and scan-to-scan variation in diffusion imaging sequences from different platforms. Schott Glass North America and The Phantom Laboratory have donated materials and personnel time to this project.

60 APPLIED LIFE SCIENCES↗

EV SALaD 2023 Demonstration: Best Practices and Mitigations for Protecting EVSE Infrastructure

The Electric Vehicle Secure Architecture Laboratory Demonstration (EV SALaD) program is a demonstration of cybersecurity best practices for high-power electric vehicle (EV) charging infrastructure led by Idaho National Laboratory (INL), in collaboration with other DOE National Laboratories participating in the EVs at Scale Consortium.a Sandia National Laboratories (SNL) and Pacific Northwest National Laboratory (PNNL) participated in the first 2-year (FY22-23) demonstration cycle for EV SALaD. This report documents the FY23 demonstration, the second in a series of demonstrations and collaborations in deploying and operating cybersecure EV charging infrastructure. It includes a summary of improvements from the FY22 demonstration, technical analysis of the FY23 demonstration, how the research demonstrates cyber-physical and cybersecurity best practices for high-power EV charging infrastructure, and related impacts to national and energy security. For EV SALaD, the FY22 demonstration focused on the detection, ranking, and prioritization of anomalous events for high-power EV charging. The FY23 demonstration additionally included the demonstration of cybersecurity best practices, which included protection and mitigation solutions to prevent, respond, and recover from anomalous events. During the demonstrations, the multi-lab EV SALaD team conducted a Test Effect Payload (TEP)b evaluation on extreme fast charger (XFC) hardware equipped with Cerberus, a detection and response solution, to demonstrate anomaly detection and mitigation cybersecurity best practices against cyber-enabled events.

33 ADVANCED PROPULSION SYSTEMS↗

Evaluating ion exchange resin efficiency and oxidative capacity for the separation of uranium(IV) and uranium(VI)

Background: Previously described methods to separate dissolved U(IV) from dissolved U(VI) under acidic anoxic conditions prior to laboratory analysis were ineffective with materials currently available commercially. Three strong anion exchange resins were examined for their efficiency in separating, recovering, and preserving both redox states during separation. Results: Under oxic conditions, recovery of U(VI) from three exchange resins (Bio-Rad AG® 1x8 Poly-Prep® prefilled columns, Bio-Rad AGW 1x8 powder, and Dowex® 1x8 powder) ranged from 72% to 100% depending on the dosed mass, eluent volume, and resin selected. Dowex® 1x8 resin was the only resin found to provide 100% recovery of U (VI) with fewer than 5 bed volumes of eluent. Under anoxic conditions, all three resins oxidized U(IV) in aqueous solutions with relatively low U(IV) concentrations (<3x10-6 M). Resin-induced oxidation was observed visually using a leuco dye, safranin-o. Oxidants associated with the resin were irreversibly reduced by the addition of Ti(III). After anoxic resin pre-treatment, a series of U(IV)/U(VI) mixtures at micro-molar levels were prepared and separated using the Dowex® 1x8 resin with 100% recovery of both U(IV) and U(VI) with no resin-induced changes in oxidation state. Conclusions: Currently available anion exchange resins with apparently identical physical properties were found to have significantly different recoveries for hexavalent uranium at micro-molar concentrations. A novel qualitative technique was developed to visually assess oxidative capacities of anion exchange resins under acidic anoxic conditions. A protocol was developed for pre-treatment and use of currently available anion exchange resins to achieve quantitative separation of U(IV) and U(VI) in aqueous solutions with low U(IV) concentrations. This method can be applied to future work to quantitatively assess dissolved U(IV) and U(VI) concentrations in both laboratory and field samples.

54 ENVIRONMENTAL SCIENCES↗

Innovative Strategy For Long Term Monitoring Of Metal And Radionuclide Plumes

Many government and private industry sites that were once contaminated with radioactive and chemical wastes cannot be cleaned up enough to permit unrestricted human access. The sites will require long term management, in some cases indefinitely, leaving site owners with the challenge of protecting human health and environmental quality at these "legacy" sites. Long-term monitoring of groundwater contamination is one of the largest projected costs in the life cycle of environmental management at the Savannah River Site, the larger DOE complex, and many large federal and private sites. There is a need to optimize the performance and manage the cost of long term surveillance and monitoring at their sites. Currently, SRNL is initiating a pilot field test using alternative protocols for long term monitoring of metals and radionuclides. A key component of the approach is that monitoring efforts are focused on measurement of low cost metrics related to hydrologic and chemical conditions that control contaminant migration. The strategy combines careful monitoring of hydrologic boundary conditions with measurement of master variables such as chemical surrogates along with a smaller number of standard well analyses. In plumes contaminated with metals, master variables control the chemistry of the groundwater system, and include redox variables (ORP, DO, chemicals), pH, specific conductivity, biological community (breakdown/decay products), and temperature. Significant changes in these variables will result in conditions whereby the plume may not be stable and therefore can be used to predict possible plume migration. Conversely, concentration measurements for all types of contaminants in groundwater are a lagging indicator plume movement - major changes contaminant concentrations indicate that contamination has migrated. An approach based on measurement of master variables and explicit monitoring of hydrologic boundary conditions combined with traditional metrics should lead to improved monitoring while simultaneously reducing costs. This paradigm is being tested at the SRS F-Area where an innovative passive remedial system is being monitored and evaluated over the long term prior to traditional regulatory closure. Contaminants being addressed at this site are uranium, strontium-90, iodine-129, and tritium. We believe that the proposed strategies will be more effective in early identification of potential risks; these strategies will also be cost effective because controlling variables are relatively simple to measure. These variables also directly reflect the evolution of the plume through time, so that the monitoring strategy can be modified as the plume 'ages'. This transformational long-term monitoring paradigm will generate large cost savings to DOE, other federal agencies and industry and will provide improved performance and leading indicators of environmental management performance.

54 ENVIRONMENTAL SCIENCES↗

Physical Property Measurements of Laboratory Prepared Saltstone Grout

The Saltstone Production Facility (SPF) built two new Saltstone Disposal Units (SDU), SDU 3 and SDU 5, in 2013. The variable frequency drive (VFD) for the grout transfer hose pump tripped due to high current demand by the motor during the initial radioactive saltstone transfer to SDU 5B on 12/5/2013. This was not observed during clean cap processing on July 5, 2013 to SDU 3A, which is a slightly longer distance from the SPF than is SDU 5B. Saltstone Design Authority (SDA) is evaluating the grout pump performance and capabilities to transfer the grout processed in SPF to SDU 3/5. To assist in this evaluation, grout physical properties are required. At this time, there are no rheological data from the actual SPF so the properties of laboratory prepared samples using simulated salt solution or Tank 50 salt solution will be measured. The physical properties of grout prepared in the laboratory with de-ionized water (DI) and salt solutions were obtained at 0.60 and 0.59 water to premix (W/P) ratios, respectively. The yield stress of the DI grout was greater than any salt grout. The plastic viscosity of the DI grout was lower than all of the salt grouts (including salt grout with admixture). When these physical data were used to determine the pressure drop and fluid horsepower for steady state conditions, the salt grouts without admixture addition required a higher pressure drop and higher fluid horsepower to transport. When 0.00076 g Daratard 17/g premix was added, both the pressure drop and fluid horsepower were below that of the DI grout. Higher concentrations of Daratard 17 further reduced the pressure drop and fluid horsepower. The uncertainty in the single point Bingham Plastic parameters is + 4% of the reported values and is the bounding uncertainty. Two different mechanical agitator mixing protocols were followed for the simulant salt grout, one having a total mixing time of three minutes and the other having a time of 10 minutes. The Bingham Plastic parameters were essentially the same for the salt grout without admixture. When Daratard 17 was added, the Bingham Plastic yield stress increased for the 10 minute mix. The simulant salt used in this task had similar physical properties of the Tank 50 3Q13 salt grout and is recommended for future use, if the salt solution in Tank 50 does not change. The design basis physical properties used to size the pumps and mixers at SPF were obtained from DPST-85-312. The grouts characterized in this report are bounded by the design basis density and Bingham Plastic yield stress. The opposite is true for the plastic viscosity. Steady state pressure drop calculations were performed for the design basis values using the flow rate for the clean cap and salt grouts and they bound the pressure drop of the grouts characterized in this report. A comparison of the lab prepared samples to PI ProcessBook data, specifically average pressure drop, indicate that the lab prepared samples are more viscous in nature than what is processed in the facility. This difference could be due to the applied shear rates which could be lower in the lab as compared to the facility and that fact the SPF added flush water, making this comparison more difficult. A perfunctory review of the PI ProcessBook data was discussed. It may be possible that the frequency that the distributed control system alters the grout pump speed to maintain grout hopper volume can negatively affect the efficiency of the grout pump.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Air Leakage and Air Transfer Between Garage and Living Space

This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the Baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air Leakage and Air Transfer Between Garage and Living Space

This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Air Leakage and Air Transfer Between Garage and Living Space, Waldorf, Maryland (Fact Sheet)

This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the Baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of inoculation practices on microbiota assembly and community stability in a fabricated ecosystem

Studying plant-microbe-soil interactions is challenging due to their high complexity and variability in natural ecosystems. While fabricated ecosystems provide opportunities to recapitulate aspects of these systems in reduced complexity and controlled environments, inoculation can be a significant source of variation. To tackle this, we evaluated how different bacteria inoculation practices and plant harvesting time points affect the reproducibility of a microbial synthetic community (SynCom) in association with the model grass Brachypodium distachyon. We tested three microbial inoculation practices: seed inoculation, transplant inoculation, and seedling inoculation; and two harvesting points: early (14-day-old plants) and late (21 days post-inoculation). We grew our plants and bacterial strains in sterile devices (EcoFABs) and characterized the microbial community from root, rhizosphere, and sand using 16S ribosomal RNA gene sequencing. The results showed that inoculation practices significantly affected the rhizosphere microbial community only when harvesting at an early time point but not at the late stage. As the SynCom showed a persistent association with B. distachyon at 21 days post-inoculation regardless of inoculation practices, we assessed the reproducibility of each inoculation method and found that transplant inoculation showed the highest reproducibility. Moreover, plant biomass was not adversely affected by transplant inoculation treatment. We concluded that bacteria inoculation while transplanting coupled with a later harvesting time point gives the most reproducible microbial community in the EcoFAB-B. distachyon-SynCom fabricated ecosystem and recommend this method as a standardized protocol for use with fabricated ecosystem experimental systems.

59 BASIC BIOLOGICAL SCIENCES↗

SU-E-T-322: Dosimetric Evaluation of Rib Dose in Peripheral Lung Tumors Treated with X-Ray Voxel Monte Carlo (XVMC) Based Lung Stereotactic Body Radiotherapy (SBRT) Following RTOG 0915 Guidelines

Purpose: To evaluate XVMC computed rib doses for peripherally located non-small-cell-lung tumors treated with SBRT following RTOG-0915 guidelines. Methods: Twenty patients with solitary peripherally located non-small-cell-lung tumors were treated using XVMC-based SBRT to 50–54Gy in 5−3 fractions, respectively, for PTV(V100%)=95%. Based on 4D-CT, ITV was delineated on MaximumIP images and organs-at-risk(OARs) including ribs were contoured on MeanIP images. Mean PTV(ITV+5mm uniform margin) was 46.1±38.7cc (range, 11.1–163.0cc). XVMC SBRT treatment plans were generated with a combination of non-coplanar 3D-conformal arcs/beams, and were delivered by Novalis-TX consisting of HD-MLCs and a 6MV-SRS(1000MU/min) beam, following RTOG-0915 criteria. XVMC rib maximum dose and dose to <1cc, <5cc, <10cc were evaluated as a function of PTV, prescription dose and 3D-distance from tumor isocenter to the most proximal rib contour. Plans were re-computed using heterogeneity-corrected pencil-beam (PB-hete) algorithm utilizing identical beam geometry/MLC positions and MUs and subsequently compared to XVMC. Results: XVMC average maximum rib dose was 50.9±6.4Gy (range, 35.1–59.3Gy). XVMC mean rib dose to <1cc was 41.6±5.6Gy (range, 27.9–47.9Gy), <5cc was 31.2±7.3Gy (range, 10.6–43.1Gy), and <10cc was 21.2±8.7Gy (range, 1.1–36Gy), respectively. For the given prescription, correlation between PTV and rib doses to <5cc (p=0.005) and <10cc (p=0.018) was observed. 3D-distance from the tumor isocenter to the proximal rib contour strongly correlated with maximum rib dose (p=0.0001). PB-hete algorithm overestimated maximum rib dose and dose to <1cc, <5cc, and <10cc of ribs by 5%, 3%, 3%, and 3%, respectively. Conclusion: PB-hete overestimates ribs dose relative to XVMC. Since all the clinical XVMC plans were generated without compromising the target coverage (per RTOG-0915), almost all patient’s ribs doses were higher than the protocol guidelines. As expected, larger tumor size and proximity to ribs received higher absolute dose to ribs. Prospective observation is needed to determine if XVMC delivered rib doses correlates with patient symptoms including chest wall pain and/or rib fractures.

60 APPLIED LIFE SCIENCES↗

Assessment of acute myocarditis by cardiac magnetic resonance imaging: Comparison of qualitative and quantitative analysis methods

Background: To compare cardiac magnetic resonance (CMR) qualitative and quantitative analysis methods for the noninvasive assessment of myocardial inflammation in patients with suspected acute myocarditis (AM). Methods: A total of 61 patients with suspected AM underwent coronary angiography and CMR. Qualitative analysis was performed applying Lake-Louise Criteria (LLC), followed by quantitative analysis based on the evaluation of edema ratio (ER) and global relative enhancement (RE). Diagnostic performance was assessed for each method by measuring the area under the curves (AUC) of the receiver operating characteristic analyses. The final diagnosis of AM was based on symptoms and signs suggestive of cardiac disease, evidence of myocardial injury as defined by electrocardiogram changes, elevated troponin I, exclusion of coronary artery disease by coronary angiography, and clinical and echocardiographic follow-up at 3 months after admission to the chest pain unit. Results: In all patients, coronary angiography did not show significant coronary artery stenosis. Troponin I levels and creatine kinase were higher in patients with AM compared to those without (both P < .001). There were no significant differences among LLC, T2-weighted short inversion time inversion recovery (STIR) sequences, early (EGE), and late (LGE) gadolinium-enhancement sequences for diagnosis of AM. The AUC for qualitative (T2-weighted STIR 0.92, EGE 0.87 and LGE 0.88) and quantitative (ER 0.89 and global RE 0.80) analyses were also similar. Conclusions: Qualitative and quantitative CMR analysis methods show similar diagnostic accuracy for the diagnosis of AM. These findings suggest that a simplified approach using a shortened CMR protocol including only T2-weighted STIR sequences might be useful to rule out AM in patients with acute coronary syndrome and normal coronary angiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Parallel transmit excitation at 1.5 T based on the minimization of a driving function for device heating

Purpose: To provide a rapid method to reduce the radiofrequency (RF) E-field coupling and consequent heating in long conductors in an interventional MRI (iMRI) setup. Methods: A driving function for device heating (W) was defined as the integration of the E-field along the direction of the wire and calculated through a quasistatic approximation. Based on this function, the phases of four independently controlled transmit channels were dynamically changed in a 1.5 T MRI scanner. During the different excitation configurations, the RF induced heating in a nitinol wire immersed in a saline phantom was measured by fiber-optic temperature sensing. Additionally, a minimization of W as a function of phase and amplitude values of the different channels and constrained by the homogeneity of the RF excitation field (B{sub 1}) over a region of interest was proposed and its results tested on the benchtop. To analyze the validity of the proposed method, using a model of the array and phantom setup tested in the scanner, RF fields and SAR maps were calculated through finite-difference time-domain (FDTD) simulations. In addition to phantom experiments, RF induced heating of an active guidewire inserted in a swine was also evaluated. Results: In the phantom experiment, heating at the tip of the device was reduced by 92% when replacing the body coil by an optimized parallel transmit excitation with same nominal flip angle. In the benchtop, up to 90% heating reduction was measured when implementing the constrained minimization algorithm with the additional degree of freedom given by independent amplitude control. The computation of the optimum phase and amplitude values was executed in just 12 s using a standard CPU. The results of the FDTD simulations showed similar trend of the local SAR at the tip of the wire and measured temperature as well as to a quadratic function of W, confirming the validity of the quasistatic approach for the presented problem at 64 MHz. Imaging and heating reduction of the guidewire were successfully performed in vivo with the proposed hardware and phase control. Conclusions: Phantom and in vivo data demonstrated that additional degrees of freedom in a parallel transmission system can be used to control RF induced heating in long conductors. A novel constrained optimization approach to reduce device heating was also presented that can be run in just few seconds and therefore could be added to an iMRI protocol to improve RF safety.

60 APPLIED LIFE SCIENCES↗

Future SDN-HPON Control Plane Architecture and Protocol for On-Demand Terabit End-to-End Extreme-Scale Science Applications

The UC Davis team conducted architecture, algorithm and experimental studies for next generation ultra-high-bandwidth optical networks in support of extreme-scale science applications. In particular, over the course of this 3-year project, the UC Davis team achieved the following main accomplishments: Designed a network architecture for automated multi-domain service provisioning: Designed information exchange schemes between autonomous systems (domains) Designed application programming interfaces to orchestrate resource reservation in data centers, high performance computation facilities, and communication networks belonging to different autonomous systems Experimentally assessed the multi-domain network architecture in a distributed field trial set-up connecting premises in three continents Designed a broker-based orchestrated multi-domain optical networking framework supporting observe-analyze-act cycle based cognitive inter-domain service provisioning: Designed an inter-domain operation mechanism, e.g., topology abstraction, for the broker plane and domain managers to collaboratively accomplish inter-domain service provisioning while respecting the autonomy of each administrative domain Designed an alien wavelength monitoring scheme and an artificial neural network based optical signal-to-noise ratio estimator for quality-of-transmission aware inter-domain service provisioning Developed a deep neural network based multi-domain traffic predictor and a cognitive routing and spectrum assignment algorithm to realize knowledge-based autonomous traffic engineering in multi-domain networks Implemented an optical signal-to-noise ratio estimator and traffic predictor with Google’s Tensor flow and assessed their performance using experimental and synthetic data Demonstrated the benefits of the proposed cognitive schemes with experiments ona two-domain elastic optical network testbed and evaluations on a six-domain simulation framework Built a two-domain software-defined networking control plane testbed using the ONOS platform and demonstrated the workflow of broker and domain manager cooperation, including hierarchical performance monitoring, topology abstraction and cognitive resource allocation. Designed self-learning cognitive service provisioning schemes using advanced machine learning technologies: Designed a self-taught anomaly detection framework for optical networks, including an unsupervised data clustering module for pattern recognition, a supervised data regression and classification module for online anomaly detection, and the system operation principle Experimentally validated the effectiveness of the self-taught anomaly detection framework with various failure/anomaly scenarios. Designed a self-learning autonomic routing, modulation and spectrum assignment (RMSA) provisioning framework for elastic optical networks with deep reinforcement learning. Designed effective modeling and training mechanisms for the self-learning RMSA framework Conducted extensive numerical simulations with various traffic patterns and topologies to verify the advantage of the self-learning RMSA framework.

42 ENGINEERING↗

Radiotherapy Does Not Influence the Severe Pulmonary Toxicity Observed With the Administration of Gemcitabine and Bleomycin in Patients With Advanced-Stage Hodgkin's Lymphoma Treated With the BAGCOPP Regimen: A Report by the German Hodgkin's Lymphoma Study Group

Purpose: To evaluate the effect of radiotherapy on the severe pulmonary toxicity observed in the pilot study of BAGCOPP (bleomycin, doxorubicin, cyclophosphamide, vincristine, procarbazine, prednisone, and gemcitabine) for advanced-stage Hodgkin's lymphoma. Methods and Materials: Patients with Stage III or IV Hodgkin's lymphoma or Stage IIB with risk factors participated in this single-arm, multicenter pilot study. Results: Twenty-seven patients were enrolled on the study before its premature closure as a result of the development of serious pulmonary toxicity in 8 patients. The pulmonary toxicity occurred either during or immediately after the BAGCOPP chemotherapy course. Pulmonary toxicity contributed to one early fatality but resolved in the other 7 patients after cessation of gemcitabine and bleomycin, allowing continuation of therapy. Fifteen patients received consolidative radiotherapy, including 4 who previously had pulmonary toxicity. There were no reported cases of radiation pneumonitis and no exacerbation of pulmonary symptoms in the 4 patients who had had previous pulmonary toxicity. Conclusions: The severe pulmonary toxicity observed in this study has been attributed to an interaction between gemcitabine and bleomycin. Gemcitabine (when administered without bleomycin) remains of interest in Hodgkin's lymphoma and is being incorporated into a new German Hodgkin's Lymphoma Study Group protocol that also includes consolidative radiotherapy. This study supports the concept of the integration of radiotherapy in gemcitabine-containing regimens in Hodgkin's lymphoma if there is an interval of at least 4 weeks between the two modalities and with a schedule whereby radiotherapy follows the chemotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗