Search NASA⌕ Search

SEARCH · Search NASA

Results for “imaging data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

SPECTROSCOPY OF LUMINOUS COMPACT BLUE GALAXIES IN DISTANT CLUSTERS. I. SPECTROSCOPIC DATA

We used the DEIMOS spectrograph on the Keck II Telescope to obtain spectra of galaxies in the fields of five distant, rich galaxy clusters over the redshift range 0.5 < z < 0.9 in a search for luminous compact blue galaxies (LCBGs). Unlike traditional studies of galaxy clusters, we preferentially targeted blue cluster members identified via multi-band photometric pre-selection based on imaging data from the WIYN telescope. Of the 1288 sources that we targeted, we determined secure spectroscopic redshifts for 848 sources, yielding a total success rate of 66%. Our redshift measurements are in good agreement with those previously reported in the literature, except for 11 targets which we believe were previously in error. Within our sample, we confirm the presence of 53 LCBGs in the five galaxy clusters. The clusters all stand out as distinct peaks in the redshift distribution of LCBGs with the average number density of LCBGs ranging from 1.65 {+-} 0.25 Mpc{sup -3} at z = 0.55 to 3.13 {+-} 0.65 Mpc{sup -3} at z = 0.8. The number density of LCBGs in clusters exceeds the field density by a factor of 749 {+-} 116 at z = 0.55; at z = 0.8, the corresponding ratio is E = 416 {+-} 95. At z = 0.55, this enhancement is well above that seen for blue galaxies or the overall cluster population, indicating that LCBGs are preferentially triggered in high-density environments at intermediate redshifts.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantum AI Based Enhanced Detection of Dementia

Quantum computing has the potential to significantly improve the early detection of Alzheimer's Disease and Related Dementias (ADRD). Quantum-enhanced machine learning can be used to perform an early screening of Alzheimer's disease using brain imaging data based on dataset of MRI scans from both healthy individuals and those diagnosed with Alzheimer's. This study aims to demonstrate the potential of quantum transfer learning to enhance the performance of the classical deep learning model for dementia detection. Using the MRI sagittal images available in the OASIS-2 (64 demented and 72 non-demented subjects between 60 and 96 years), we show how quantum techniques can transform a suboptimal classical model into a more effective solution for dementia detection, highlighting their potential impact on advancing healthcare technology. We begin with a simple classical deep learning model with a significantly smaller number of parameters, which gives suboptimal performance on the problem. Then, we apply different configurations of quantum transfer learning based on the pre-trained weak classifier (Figure 1). We fix the weak classifier's initial convolutional layers at their fixed pre-trained parameters and replace the last set of dense layers with a dressed quantum circuit (DQN), which we train to enhance performance. We performed 4-fold cross-validation for both the classical and the hybrid quantum models and trained them using Pennylane's `default.qubit' simulator and IonQ's Aria-1 simulator (noisy simulation). We showed that with significantly fewer parameters, the quantum transfer learning-based hybrid models showed significant performance enhancement over the base weak classical deep learning model for dementia detection. To classify between a demented and non-demented subject, the accuracy of quantum-based AI methods improved by 6 to 14% compared to classical methods. The sensitivity of the models improved by 4 to 17%. This shows that there are fewer chances of misclassifying demented patients. Figure 2 compares the performance of the hybrid quantum models and their base classical model, and Table 1 summarizes the results. We illustrated that with assistance from quantum machine learning, it is possible to enhance detection for dementia based on brain images. This shows the potential for practical utility of quantum computing in ADRD research.

Bhowmik, Sounak [University of Tennessee, Knoxvill↗

Invited Article: Relation between electric and magnetic field structures and their proton-beam images

Proton imaging is commonly used to reveal the electric and magnetic fields that are found in high energy density plasmas. Presented here is an analysis of this technique that is directed towards developing additional insight into the underlying physics. This approach considers: formation of images in the limits of weak and strong intensity variations; caustic formation and structure; image inversion to obtain line-integrated field characteristics; direct relations between images and electric or magnetic field structures in a plasma; imaging of sharp features such as Debye sheaths and shocks. Limitations on spatial and temporal resolution are assessed, and similarities with optical shadowgraphy are noted. Synthetic proton images are presented to illustrate the analysis. These results will be useful for quantitatively analyzing experimental proton imaging data and verifying numerical codes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A HIGHLY ELONGATED PROMINENT LENS AT z = 0.87: FIRST STRONG-LENSING ANALYSIS OF EL GORDO

We present the first strong-lensing (SL) analysis of the galaxy cluster ACT-CL J0102-4915 (El Gordo), in recent HST/ACS images, revealing a prominent strong lens at a redshift of z = 0.87. This finding adds to the already-established unique properties of El Gordo: it is the most massive, hot, X-ray luminous, and bright Sunyaev-Zeldovich effect cluster at z {approx}> 0.6, and the only {sup b}ullet{sup -}like merging cluster known at these redshifts. The lens consists of two merging massive clumps, where, for a source redshift of z{sub s} {approx} 2, each clump exhibits only a small, separate critical area, with a total area of 0.69 {+-} 0.11{open_square}' over the two clumps. For a higher source redshift, z{sub s} {approx} 4, the critical curves of the two clumps merge together into one bigger and very elongated lens (axis ratio {approx_equal} 5.5), enclosing an effective area of 1.44 {+-} 0.22{open_square}'. The critical curves continue expanding with increasing redshift so that for high-redshift sources (z{sub s} {approx}> 9) they enclose an area of {approx}1.91 {+-} 0.30{open_square}' (effective {theta}{sub e} {approx_equal} 46.''8 {+-} 3.''7) and a mass of 6.09 {+-} 1.04 Multiplication-Sign 10{sup 14} M{sub Sun }. According to our model, the area of high magnification ({mu} > 10) for such high-redshift sources is {approx_equal}1.2{open_square}', and the area with {mu} > 5 is {approx_equal}2.3{open_square}', making El Gordo a compelling target for studying the high-redshift universe. We obtain a strong lower limit on the total mass of El Gordo, {approx}> 1.7 Multiplication-Sign 10{sup 15} M{sub Sun} from the SL regime alone, suggesting a total mass of roughly M{sub 200} {approx} 2.3 Multiplication-Sign 10{sup 15} M{sub Sun }. Our results should be revisited when additional spectroscopic and HST imaging data are available.

79 ASTRONOMY AND ASTROPHYSICS↗

TU-F-BRF-04: Registration of 3D Transesophageal Echocardiography and X-Ray Fluoroscopy Using An Inverse Geometry X-Ray System

Purpose: To develop a method for the fusion of 3D echocardiography and Scanning-Beam Digital X-ray (SBDX) fluoroscopy to assist with catheter device and soft tissue visualization during interventional procedures. Methods: SBDX is a technology for low-dose inverse geometry x-ray fluoroscopy that performs digital tomosynthesis at multiple planes in real time. In this study, transesophageal echocardiography (TEE) images were fused with SBDX images by estimating the 3D position and orientation (the “pose”) of the TEE probe within the x-ray coordinate system and then spatially transforming the TEE image data to match this pose. An initial pose estimate was obtained through tomosynthesis-based 3D localization of points along the probe perimeter. Position and angle estimates were then iteratively refined by comparing simulated projections of a 3D probe model against SBDX x-ray images. Algorithm performance was quantified by imaging a TEE probe in different known orientations and locations within the x-ray field (0-30 degree tilt angle, up to 50 mm translation). Fused 3D TEE/SBDX imaging was demonstrated by imaging a tissue-mimicking polyvinyl alcohol cylindrical cavity as a catheter was navigated along the cavity axis. Results: Detected changes in probe tilt angle agreed with the known changes to within 1.2 degrees. For a 50 mm translation along the source-detector axis, the detected translation was 50.3 mm. Errors for in-plane translations ranged from 0.1 to 0.9 mm. In a fused 3D TEE/SBDX display, the catheter device was well visualized and coincident with the device shadow in the TEE images. The TEE images portrayed phantom boundaries that were not evident under x-ray. Conclusion: Registration of soft tissue anatomy derived from TEE imaging and device imaging from SBDX x-ray fluoroscopy is feasible. The simultaneous 3D visualization of these two modalities may be useful in interventional procedures involving the navigation of devices to soft tissue anatomy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rectification of single and multiple frames of satellite scanner imagery using points and edges as control

Rectification of single and overlapping multiple scanner frames produced by such satellite-borne scanners as the LANDSAT MSS was carried out using a newly developed comprehensive parametric model. Tests with both simulated and real image data demonstrate conclusively that this model in general is superior to the widely used polynomial model, and that the simultaneous rectification of overlapping frames using least squares techniques yields a high accuracy than sngle frame rectification due to the inclusion of tie points between the image frames. Used to control, edges or lines, whic are much more likely to be found in images, can replace conventional control points and can easily be implemented into the least squares approach. An efficient algorithm for findng corresponding points in image paris was developed which can be used for determining tie points between image frames and thus increase the ecnomy of the whole rectification procedure.

Paderes, F. C., Jr.↗

PIPS: A Procedure for Interactive Pyramid Segmentation

The Procedure for Interactive Pyramid Segementation was designed to identify regions of spatially connected and spectrally homogeneous pixels in multispectral image data, and to allow these regions to be interactively manipulated without the use of processing parameters. The objective is to provide the user with the capability to easily extract and identify regions corresponding to target objects of interest. The approach is to segment a multispectral image into a set of regions and to allow the analyst to interactively refine the segmentation by direct manipulation. The user can elect to: interactively display maps of the spatial distribution of regions for any designated image subset; display the statistics of a given region; and label, merge, or split regions.

Wharton, S. W.↗

Lens Model and Source Reconstruction Reveal the Morphology and Star Formation Distribution in the Cool Spiral LIRG SGAS J143845.1+145407

We present Hubble Space Telescope (HST) imaging and grism spectroscopy of a strongly lensed LIRG at z = 0.816, SGAS 143845.1+145407, and use the magnification boost of gravitational lensing to study the distribution of star formation throughout this galaxy. Based on the HST imaging data, we create a lens model for this system; we compute the mass distribution and magnification map of the z = 0.237 foreground lens. We find that the magnification of the lensed galaxy ranges between 2 and 10, with a total magnification (measured over all the images of the source) of μ = ${11.8}_{-2.4}^{+4.6}$. We find that the total projected mass density within ∼34 kpc of the brightest cluster galaxy is 6.0(+0.3,-0.7) x 10^(12)Mꙩ. Using the lens model we create a source reconstruction for SGAS 143845.1+145407, which, paired with a faint detection of Hα in the grism spectroscopy, allows us to finally comment directly on the distribution of star formation in a z ∼ 1 LIRG. We find widespread star formation across this galaxy, in agreement with the current understanding of these objects. However, we note a deficit of Hα emission in the nucleus of SGAS 143845.1+145407, likely due to dust extinction.

Samuel J. Dunham↗

Analysis of deformable image registration accuracy using computational modeling

Computer aided modeling of anatomic deformation, allowing various techniques and protocols in radiation therapy to be systematically verified and studied, has become increasingly attractive. In this study the potential issues in deformable image registration (DIR) were analyzed based on two numerical phantoms: One, a synthesized, low intensity gradient prostate image, and the other a lung patient's CT image data set. Each phantom was modeled with region-specific material parameters with its deformation solved using a finite element method. The resultant displacements were used to construct a benchmark to quantify the displacement errors of the Demons and B-Spline-based registrations. The results show that the accuracy of these registration algorithms depends on the chosen parameters, the selection of which is closely associated with the intensity gradients of the underlying images. For the Demons algorithm, both single resolution (SR) and multiresolution (MR) registrations required approximately 300 iterations to reach an accuracy of 1.4 mm mean error in the lung patient's CT image (and 0.7 mm mean error averaged in the lung only). For the low gradient prostate phantom, these algorithms (both SR and MR) required at least 1600 iterations to reduce their mean errors to 2 mm. For the B-Spline algorithms, best performance (mean errors of 1.9 mm for SR and 1.6 mm for MR, respectively) on the low gradient prostate was achieved using five grid nodes in each direction. Adding more grid nodes resulted in larger errors. For the lung patient's CT data set, the B-Spline registrations required ten grid nodes in each direction for highest accuracy (1.4 mm for SR and 1.5 mm for MR). The numbers of iterations or grid nodes required for optimal registrations depended on the intensity gradients of the underlying images. In summary, the performance of the Demons and B-Spline registrations have been quantitatively evaluated using numerical phantoms. The results show that parameter selection for optimal accuracy is closely related to the intensity gradients of the underlying images. Also, the result that the DIR algorithms produce much lower errors in heterogeneous lung regions relative to homogeneous (low intensity gradient) regions, suggests that feature-based evaluation of deformable image registration accuracy must be viewed cautiously.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Data Summarization and Inference at Scale

This is the final report for the DOE ASCR grant SC-0022260, Data Summarization and Inference at Scale, PI: Alex Pothen, Purdue University. The goal of the project was to solve data-intensive and compute-intensive problems in the physical sciences, engineering, information science, data science, etc. by designing and implementing new algorithms that could work with a subset of the data. The four subgoals were: (a) The solution of problems where the data is too large to be stored in the memory of a computer. In this streaming model of computation, the data arrives as a stream of elements to the computer, each element is processed as it arrives, and a decision is made to discard the data or to store it; only a small subset of the data proportional to the size of the output solution is stored, and when all the data has been streamed, a solution to the problem is computed from the stored subset. (b) The use of machine learning methods to compute solutions to data-intensive problems. The use of GPUs is critical to obtain high performance on machine learning tasks, but their memory sizes are smaller relative to that of CPUs. For large-scale problems, the data is sampled many times, and small samples are used with repetition, for robustness, to compute solutions to inference tasks. This sampling reduces the memory required to solve the problem, but attention is needed to avoid slow convergence to the solutions, and reduced accuracy of inference. We propose submodular optimization, Large Language Models, and physics-informed neural networks to enable GPU computations here. (c) Modeling and visualization of high-dimensional data using interpretable features. Clinical proteomic data sets from immunology for the detection of cancer and other diseases are temporal and high-dimensional, and algorithms for visualizing these data sets using clinically interpretable features are lacking. We propose methods that compute distances based on the optimal transportation problem and graph edit distances to address this problem. We also propose the use of optimal transport-based distances, spatial statistics, and network structure to classify image data sets, We apply these algorithms to electron micrographs of the peripheral nervous system in the digestive tract. (d) The design of data-intensive algorithms on emerging architectures, specifically, noisy, intermediate-scale quantum (NISQ) devices. Quantum computers offer the possibility of exploring large solution spaces due to the principle of superposition, but current quantum computers are limited by few qubits, short coherence times due to noise, poor interconections among the qubits, etc. We propose the use of the divide and conquer paradigm to solve large-scale problems, wherein collections of small subproblems are solved on the quantum devices, and the solutions to the subproblems are integrated into a solution for the original problem on a classical computer.

97 MATHEMATICS AND COMPUTING↗

The final SDSS high-redshift quasar sample of 52 quasars at z > 5.7

We present the discovery of nine quasars at z∼6 identified in the Sloan Digital Sky Survey (SDSS) imaging data. This completes our survey of z∼6 quasars in the SDSS footprint. Our final sample consists of 52 quasars at 5.7<z⩽6.4, including 29 quasars with z{sub AB}⩽20 mag selected from 11,240 deg{sup 2} of the SDSS single-epoch imaging survey (the main survey), 10 quasars with 20⩽z{sub AB}⩽20.5 selected from 4223 deg{sup 2} of the SDSS overlap regions (regions with two or more imaging scans), and 13 quasars down to z{sub AB}≈22 mag from the 277 deg{sup 2} in Stripe 82. They span a wide luminosity range of −29.0⩽M{sub 1450}⩽−24.5. This well-defined sample is used to derive the quasar luminosity function (QLF) at z∼6. After combining our SDSS sample with two faint (M{sub 1450}⩾−23 mag) quasars from the literature, we obtain the parameters for a double power-law fit to the QLF. The bright-end slope β of the QLF is well constrained to be β=−2.8±0.2. Due to the small number of low-luminosity quasars, the faint-end slope α and the characteristic magnitude M{sub 1450}{sup ∗} are less well constrained, with α=−1.90{sub −0.44}{sup +0.58} and M{sup ∗}=−25.2{sub −3.8}{sup +1.2} mag. The spatial density of luminous quasars, parametrized as ρ(M{sub 1450}<−26,z)=ρ(z=6)10{sup k(z−6)}, drops rapidly from z∼5 to 6, with k=−0.72±0.11. Based on our fitted QLF and assuming an intergalactic medium (IGM) clumping factor of C = 3, we find that the observed quasar population cannot provide enough photons to ionize the z∼6 IGM at ∼90% confidence. Quasars may still provide a significant fraction of the required photons, although much larger samples of faint quasars are needed for more stringent constraints on the quasar contribution to reionization.

79 ASTRONOMY AND ASTROPHYSICS↗

Joint Strong and Weak Lensing Analysis of the Massive Cluster Field J0850+3604

In this work, we present a combined strong and weak lensing analysis of the J085007.6+360428 (J0850) field, which contains the massive cluster Zwicky 1953. This field was selected for its high projected concentration of luminous red galaxies. Using Subaru/Suprime-Cam ${{BVR}}_{c}{I}_{c}{i}^{\prime }{z}^{\prime }$ imaging and MMT/Hectospec spectroscopy, we first perform a weak lensing shear analysis to constrain the mass distribution in this field, including the cluster at z = 0.3774 and a smaller foreground halo at z = 0.2713. We then add a strong lensing constraint from a multiply imaged galaxy in the imaging data with a photometric redshift of z ≈ 5.03. Unlike previous cluster-scale lens analyses, our technique accounts for the full three-dimensional mass structure in the beam, including galaxies along the line of sight. In contrast with past cluster analyses that used only lensed image positions as constraints, we use the full surface brightness distribution of the images. This method predicts that the source galaxy crosses a lensing caustic, such that one image is a highly magnified "fold arc" that could be used to probe the source galaxy's structure at ultra-high spatial resolution (<30 pc). We calculate the mass of the primary cluster to be ${M}_{\mathrm{vir}}={2.93}_{-0.65}^{+0.71}\times {10}^{15}\,{M}_{\odot }$ with a concentration of ${c}_{\mathrm{vir}}={3.46}_{-0.59}^{+0.70}$, consistent with the mass–concentration relation of massive clusters at a similar redshift. Finally, the large mass of this cluster makes J0850 an excellent field for leveraging lensing magnification to search for high-redshift galaxies, competitive with and complementary to that of well-studied clusters such as the HST Frontier Fields.

79 ASTRONOMY AND ASTROPHYSICS↗

Passive IFF: Autonomous Nonintrusive Rapid Identification of Friendly Assets

A proposed optoelectronic instrument would identify targets rapidly, without need to radiate an interrogating signal, apply identifying marks to the targets, or equip the targets with transponders. The instrument was conceived as an identification, friend or foe (IFF) system in a battlefield setting, where it would be part of a targeting system for weapons, by providing rapid identification for aimed weapons to help in deciding whether and when to trigger them. The instrument could also be adapted to law-enforcement and industrial applications in which it is necessary to rapidly identify objects in view. The instrument would comprise mainly an optical correlator and a neural processor (see figure). The inherent parallel-processing speed and capability of the optical correlator would be exploited to obtain rapid identification of a set of probable targets within a scene of interest and to define regions within the scene for the neural processor to analyze. The neural processor would then concentrate on each region selected by the optical correlator in an effort to identify the target. Depending on whether or not a target was recognized by comparison of its image data with data in an internal database on which the neural processor was trained, the processor would generate an identifying signal (typically, friend or foe ). The time taken for this identification process would be less than the time needed by a human or robotic gunner to acquire a view of, and aim at, a target. An optical correlator that has been under development for several years and that has been demonstrated to be capable of tracking a cruise missile might be considered a prototype of the optical correlator in the proposed IFF instrument. This optical correlator features a 512-by-512-pixel input image frame and operates at an input frame rate of 60 Hz. It includes a spatial light modulator (SLM) for video-to-optical image conversion, a pair of precise lenses to effect Fourier transforms, a filter SLM for digital-to-optical correlation-filter data conversion, and a charge-coupled device (CCD) for detection of correlation peaks. In operation, the input scene grabbed by a video sensor is streamed into the input SLM. Precomputed correlation-filter data files representative of known targets are then downloaded and sequenced into the filter SLM at a rate of 1,000 Hz. When there occurs a match between the input target data and one of the known-target data files, the CCD detects a correlation peak at the location of the target. Distortion- invariant correlation filters from a bank of such filters are then sequenced through the optical correlator for each input frame. The net result is the rapid preliminary recognition of one or a few targets.

Moynihan, Philip↗

The Sloan Digital Sky Survey-II Photometry and Supernova IA Light Curves from the 2005 Data

We present ugriz light curves for 146 spectroscopically-confirmed or spectroscopically-probable Type Ia supernovae (SNe) from the 2005 season of the Sloan Digital Sky Survey-II Supernova (SN) survey. The light curves have been constructed using a photometric technique that we call scene modeling, which is described in detail here; the major feature is that SN brightnesses are extracted from a stack of images without spatial resampling or convolution of the image data. This procedure produces accurate photometry along with accurate estimates of the statistical uncertainty, and can be used to derive photometry taken with multiple telescopes. We discuss various tests of this technique that demonstrate its capabilities. We also describe the methodology used for the calibration of the photometry, and present calibrated magnitudes and fluxes for all of the spectroscopic SNe Ia from the 2005 season.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The IPAC Image Subtraction and Discovery Pipeline for the Intermediate Palomar Transient Factory

We describe the near real-time transient-source discovery engine for the intermediate Palomar Transient Factory (iPTF), currently in operations at the Infrared Processing and Analysis Center (IPAC), Caltech. We coin this system the IPAC/iPTF Discovery Engine (or IDE). We review the algorithms used for PSF-matching, image subtraction, detection, photometry, and machine-learned (ML) vetting of extracted transient candidates. We also review the performance of our ML classifier. For a limiting signal-to-noise ratio of 4 in relatively unconfused regions, bogus candidates from processing artifacts and imperfect image subtractions outnumber real transients by approximately equal to 10:1. This can be considerably higher for image data with inaccurate astrometric and/or PSF-matching solutions. Despite this occasionally high contamination rate, the ML classifier is able to identify real transients with an efficiency (or completeness) of approximately equal to 97% for a maximum tolerable false-positive rate of 1% when classifying raw candidates. All subtraction-image metrics, source features, ML probability-based real-bogus scores, contextual metadata from other surveys, and possible associations with known Solar System objects are stored in a relational database for retrieval by the various science working groups. We review our efforts in mitigating false-positives and our experience in optimizing the overall system in response to the multitude of science projects underway with iPTF.

methods: analytical – methods: data analysis –↗

Understanding the Influence of Receptive Field and Network Complexity in Neural Network-Guided TEM Image Analysis

Abstract Trained neural networks are promising tools to analyze the ever-increasing amount of scientific image data, but it is unclear how to best customize these networks for the unique features in transmission electron micrographs. Here, we systematically examine how neural network architecture choices affect how neural networks segment, or pixel-wise separate, crystalline nanoparticles from amorphous background in transmission electron microscopy (TEM) images. We focus on decoupling the influence of receptive field, or the area of the input image that contributes to the output decision, from network complexity, which dictates the number of trainable parameters. For low-resolution TEM images which rely on amplitude contrast to distinguish nanoparticles from background, we find that the receptive field does not significantly influence segmentation performance. On the other hand, for high-resolution TEM images which rely on both amplitude and phase-contrast changes to identify nanoparticles, receptive field is an important parameter for increased performance, especially in images with minimal amplitude contrast. Rather than depending on atom or nanoparticle size, the ideal receptive field seems to be inversely correlated to the degree of nanoparticle contrast in the image. Our results provide insight and guidance as to how to adapt neural networks for applications with TEM datasets.

42 ENGINEERING↗

First point-spread function and x-ray phase-contrast imaging results with an 88-mm diameter single crystal

In this paper, we report initial demonstrations of the use of single crystals in indirect x-ray imaging with a benchtop implementation of propagation-based (PB) x-ray phase contrast imaging. Based on single Gaussian peak fits to the x-ray images, we observed a four times smaller system point-spread function (PSF) with the 50-μm thick single crystal scintillators than with the reference polycrystalline phosphor/scintillator. Fiber-optic plate depth-of-focus and Al reflective-coating aspects are also elucidated. Guided by the results from the 25-mm diameter crystal samples, we report additionally the first results with a unique 88-mm diameter single crystal bonded to a fiber optic plate and coupled to the large format CCD. Both PSF and x-ray phase contrast imaging data are quantified and presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-C-BRF-01: Pediatric Treatment Planning I: Overview of Planning Strategies

Most Medical Physicists working in radiotherapy departments see few pediatric patients. This is because, fortunately, children get cancer at a rate nearly 100 times lower than adults. Children have not smoked, abused alcohol, or been exposed to environmental carcinogens for decades, and of course, have not fallen victim to the aging process. Children get very different cancers than adults. Breast or prostate cancers, typical in adults, are rarely seen in children but instead a variety of tumors occur in children that are rarely seen in adults; examples are germinomas, ependymomas and primitive neuroectodermal tumors, which require treatment of the child's brain or neuroblastoma, requiring treatment in the abdomen. The treatment of children with cancer using radiation therapy is one of the most challenging planning and delivery problems facing the physicist. This is because bones, brain, breast tissue, and other organs are more sensitive to radiation in children than in adults. Because most therapy departments treat mostly adults, when the rare 8 year-old patient comes to the department for treatment, the physicist may not understand the clinical issues of his disease which drive the planning and delivery decisions. Additionally, children are more prone than adults to developing secondary cancers after radiation. This fact has important implications for the choice of delivery techniques, especially when considering IMRT. For bilateral retinoblastoma for example, an irradiated child has a 50% chance of developing a second cancer by age 50. In the first presentation, an overview of childhood cancers and their corresponding treatment techniques will be given. These can be some of the most complex treatments that are delivered in the radiation therapy department. These cancers include leukemia treated with total body irradiation, medulloblastoma, treated with craniospinal irradiation plus a conformal boost to the posterior fossa, neuroblastoma, requiring focal abdominal irradiation to avoid kidney, liver, and vertebral body damage, retinoblastoma, requiring treatment to an eye while minimizing dose to surrounding tissues, and a variety of other tumors which occur anywhere in the body. Case studies will be presented showing the treatment technique and resulting dosimetry, highlighting the objectives for tumor coverage and organ-at-risk sparing. Practical issues that have to be faced when treating children will also be discussed such as daily sedation and immobilization. In the second presentation, specific focus will be on radiation therapy simulation, treatment planning guidelines, image guidance for delivery, and proton therapy for children. We will discuss uniqueness of pediatric simulation with different imaging modalities (CT, MRI, and PET). Some related issues are sedation for younger patients, radiation exposure reduction for CT, distortion and artifacts on pediatric MRI, and measuring pediatric organ motion. We will discuss the tradeoff of tumor coverage and normal tissue sparing in treatment planning using example organ data. Image guidance approaches for pediatric radiation therapy and methods for dose reduction will be reviewed. Finally, we will describe technical advances and trends in proton therapy for children. Advantages, caveats, and opportunities will be presented. Learning Objectives: Improve understanding about childhood cancer and treatment with radiation Understand treatment planning and delivery issues specific to children Become aware of specific treatment methods for the most challenging pediatric cancers Know the current status of state-of-the-art treatment techniques for pediatric radiation therapy.

60 APPLIED LIFE SCIENCES↗