Mechanical Behavior of Titanium-Based Layered Structures Fabricated Using Blended Elemental Powder Metallurgy

Mechanical behavior of bilayered structures composed of the layer of Ti-6Al-4 V (wt.%) (Ti-64) alloy and metal matrix composite (MMC) on the base of this alloy reinforced with 5 and 10% (vol.) of either TiB or TiC particles has been studied. Structures were fabricated using blended elemental powder metallurgy and studied by tensile and three-point flexural tests. Mechanical tests were performed on uniform single-layer samples of the alloy as well as individual MMCs. In addition, bilayered structures were also tested in three-point flexural experiment. Posttest fractographic inspections were made using the SEM. The deformation energy was measured based on engineering stress–strain curves obtained on tensile test. The results were compared with the data previously reported on Ti-64 alloy fabricated using cast and wrought technique. The presence of TiB and TiC reinforcement particles in the alloy causes substantial drop in strength and ductility of MMCs as compared to uniform sintered Ti-64 alloy, since those particles provide additional sites for the cracks and pores nucleation and promote the embrittlement of material. However, when MMC layers are used in bilayered structures with Ti-64 alloy layers, the three-point flexural test demonstrates significant increase in flexure stress compared to uniform Ti-64 alloy and uniform structures of MMCs. The suitability of studied structures for antiballistic impact application is discussed.

36 MATERIALS SCIENCE↗

Anisotropy in thermal conductivity of graphite flakes–SiC{sub p}/matrix composites: Implications in heat sinking design for thermal management applications

Within the frame of heat dissipation for electronics, a very interesting family of anisotropic composite materials, fabricated by liquid infiltration of a matrix into preforms of oriented graphite flakes and SiC particles, has been recently proposed. Aiming to investigate the implications of the inherent anisotropy of these composites on their thermal conductivity, and hence on their potential applications, materials with matrices of Al–12 wt.% Si alloy and epoxy polymer have been fabricated. Samples have been cut at a variable angle with respect to the flakes plane and thermal conductivity has been measured by means of two standard techniques, namely, steady state technique and laser flash method. Experimental results are presented and discussed in terms of current models, from which important technological implications for heat sinking design can be derived. - Highlights: • Anisotropy in thermal conductivity of graphite flakes-based composites is evaluated. • Samples are cut in a direction forming a variable angle with the oriented flakes. • For angles 0° and 90°, thermal conductivity does not depend on sample geometry. • For intermediate angles, thermal conductivity strongly depends on sample geometry. • “Thin” samples must be thicker than 600 μm, “thick” samples must be encapsulated.

36 MATERIALS SCIENCE↗

Advances in bone preservation: Identifying possible collagen preservation using sulfur speciation mapping

The complexity and heterogeneity of bone chemistry makes it difficult to discern information on physiological and taphonomic processes stored within the bone matrix. Analysis of archaeological and palaeontological bone becomes more difficult because in many cases the most pivotal specimens are too scientifically valuable for destructive analysis. Here, this problem is further escalated by the fact that the heterogeneity of the bone may cause small “pockets” of preservation that can be missed during sampling. Therefore, a non-destructive technique that can spatially resolve such heterogeneity within the bone is needed.

36 MATERIALS SCIENCE↗

Selecting registration schemes in case of interstitial lung disease follow-up in CT

Purpose: Primary goal of this study is to select optimal registration schemes in the framework of interstitial lung disease (ILD) follow-up analysis in CT. Methods: A set of 128 multiresolution schemes composed of multiresolution nonrigid and combinations of rigid and nonrigid registration schemes are evaluated, utilizing ten artificially warped ILD follow-up volumes, originating from ten clinical volumetric CT scans of ILD affected patients, to select candidate optimal schemes. Specifically, all combinations of four transformation models (three rigid: rigid, similarity, affine and one nonrigid: third order B-spline), four cost functions (sum-of-square distances, normalized correlation coefficient, mutual information, and normalized mutual information), four gradient descent optimizers (standard, regular step, adaptive stochastic, and finite difference), and two types of pyramids (recursive and Gaussian-smoothing) were considered. The selection process involves two stages. The first stage involves identification of schemes with deformation field singularities, according to the determinant of the Jacobian matrix. In the second stage, evaluation methodology is based on distance between corresponding landmark points in both normal lung parenchyma (NLP) and ILD affected regions. Statistical analysis was performed in order to select near optimal registration schemes per evaluation metric. Performance of the candidate registration schemes was verified on a case sample of ten clinical follow-up CT scans to obtain the selected registration schemes. Results: By considering near optimal schemes common to all ranking lists, 16 out of 128 registration schemes were initially selected. These schemes obtained submillimeter registration accuracies in terms of average distance errors 0.18 ± 0.01 mm for NLP and 0.20 ± 0.01 mm for ILD, in case of artificially generated follow-up data. Registration accuracy in terms of average distance error in clinical follow-up data was in the range of 1.985–2.156 mm and 1.966–2.234 mm, for NLP and ILD affected regions, respectively, excluding schemes with statistically significant lower performance (Wilcoxon signed-ranks test, p < 0.05), resulting in 13 finally selected registration schemes. Conclusions: Selected registration schemes in case of ILD CT follow-up analysis indicate the significance of adaptive stochastic gradient descent optimizer, as well as the importance of combined rigid and nonrigid schemes providing high accuracy and time efficiency. The selected optimal deformable registration schemes are equivalent in terms of their accuracy and thus compatible in terms of their clinical outcome.

60 APPLIED LIFE SCIENCES↗

WE-AB-207B-07: Dose Cloud: Generating “Big Data” for Radiation Therapy Treatment Plan Optimization Research

Purpose: To provide a tool to generate large sets of realistic virtual patient geometries and beamlet doses for treatment optimization research. This tool enables countless studies exploring the fundamental interplay between patient geometry, objective functions, weight selections, and achievable dose distributions for various algorithms and modalities. Methods: Generating realistic virtual patient geometries requires a small set of real patient data. We developed a normalized patient shape model (PSM) which captures organ and target contours in a correspondence-preserving manner. Using PSM-processed data, we perform principal component analysis (PCA) to extract major modes of variation from the population. These PCA modes can be shared without exposing patient information. The modes are re-combined with different weights to produce sets of realistic virtual patient contours. Because virtual patients lack imaging information, we developed a shape-based dose calculation (SBD) relying on the assumption that the region inside the body contour is water. SBD utilizes a 2D fluence-convolved scatter kernel, derived from Monte Carlo simulations, and can compute both full dose for a given set of fluence maps, or produce a dose matrix (dose per fluence pixel) for many modalities. Combining the shape model with SBD provides the data needed for treatment plan optimization research. Results: We used PSM to capture organ and target contours for 96 prostate cases, extracted the first 20 PCA modes, and generated 2048 virtual patient shapes by randomly sampling mode scores. Nearly half of the shapes were thrown out for failing anatomical checks, the remaining 1124 were used in computing dose matrices via SBD and a standard 7-beam protocol. As a proof of concept, and to generate data for later study, we performed fluence map optimization emphasizing PTV coverage. Conclusions: We successfully developed and tested a tool for creating customizable sets of virtual patients suitable for large-scale radiation therapy optimization research.

60 APPLIED LIFE SCIENCES↗

Neutron Capture and Transmission Measurements and Evaluation of 54 Fe at the RPI LINAC [Slides]

This presentation covers neutron capture and transmission measurements and evaluation of 54 Fe (Iron) at the Rensselaer Polytechnic Insitute (RPI) Linear Accelerator (LINAC). Presentation conclusions find that 54 Fe is near its conclusion, covariance matrix generation is needed for both experiments before data is made available and released (Completion by April 2023). RPI will be conducting a full Resolved Resonance Region (RRR) evaluation following release of data (Completion by September 2023). Additionally, the neutron beam imager shows promise in providing an easy way to align samples in the most intense part of the neutron beam and there will be a new evaluation that will offer improvements in crit safety, shielding, and stellar applications.

07 ISOTOPE AND RADIATION SOURCES↗

Combining Spin-Seebeck and Nernst Effects in Aligned MnBi/Bi Composites

The spin-Seebeck effect (SSE) is an advective transport process traditionally studied in bilayers composed of a ferromagnet (FM) and a non-magnetic metal (NM) with strong spin-orbit coupling. In a temperature gradient, the flux of magnons in the FM transfers spin-angular momentum to electrons in the NM, which by the inverse spin-Hall effect generates an SSE voltage. In contrast, the Nernst effect is a bulk transport phenomenon in homogeneous NMs or FMs. These effects share the same geometry, and we show here that they can be added to each other in a new combination of FM/NM composites where synthesis via in-field annealing results in the FM material (MnBi) forming aligned needles inside an NM matrix with strong spin-orbit coupling (SOC) (Bi). Through examination of the materials’ microstructural, magnetic, and transport properties, we searched for signs of enhanced transverse thermopower facilitated by an SSE contribution from MnBi adding to the Nernst effect in Bi. Our results indicate that these two signals are additive in samples with lower MnBi concentrations, suggesting a new way forward in the study of SSE composite materials.

36 MATERIALS SCIENCE↗

Validation of general purpose mathematical efficiency modeling with ISOCS - 15579

Gamma spectroscopy is a commonly used method for radioactive waste characterization and activity determination in in-situ objects. The gamma rays emitted by radionuclides in the waste container matrix are highly penetrating and can be measured using one or more gamma ray detectors, thus allowing for a passive nondestructive assay. One problem is that a source based calibration of full energy peak efficiency can be difficult or impractical because of the large size and/or an unusual shape of the sample geometry. One attractive solution is to use mathematical efficiency modeling to calculate the full energy peak efficiency. The In-Situ Object Calibration Software (ISOCS) has successfully been used for more than a decade for mathematical efficiency modeling of template based geometries. Templates include the most common objects in waste characterization and D and D, including but not limited to: boxes, drums, and pipes with hotspots, beams, tanks and walls. Scenarios exist where these templates cannot model the desired measurement geometry. Canberra has developed a general purpose version of ISOCS where primitive objects can be combined into practically any geometry. The primitive objects are right circular cylinder, right elliptical cylinder, right circular cone, right elliptical cone, sphere, spheroid, ellipsoid, box (rectangular parallelepiped), torus, and beaker (any cylindrical symmetric object). Multiple primitive objects can be combined using the priority scheme and cut by planes into almost any desired shape. In addition, multiple objects can be defined in the same scene, for example cylinders next to each other or a pipe and a box. Collimators can be constructed as easily as in template based ISOCS. The ray tracing algorithm in ISOCS has been extended to support the new primitive objects for attenuation calculation between the radioactive source and the detector end cap. The new version uses the same vacuum efficiency response, or characterization, in the energy range 10 - 7000 keV of individual detectors to be able to calculate the efficiency as accurately as possible. MCNP has been shown to be able to calculate detection efficiencies for any geometry and the new version of ISOCS have been validated to MCNP. The vacuum efficiency is based on an MCNP model and this model was the base for constructing an identical model in MCNP as in ISOCS. The calculated efficiencies from the two codes have been compared and the agreement is within 3% except for the lowest energies for one geometry. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Robust Predictive Control for Modular Solid-State Transformer With Reduced DC Link and Parameter Mismatch

This paper presents the analysis and implementation of a predictive control method for dc-link regulation and voltage balance in a cascaded modular reduced dc-link solid-state transformer (SST). Passive components like bulky dc links limit the power density of power converters, especially medium-voltage (MV) SST. Reduced dc-link or low-inertia converters can dramatically reduce the size, cost, and weight by tolerating larger dc-link ripples and improve the reliability with electrolytic capacitor-less dc link. However, a small dc link leads to tight coupling between the input and the output stages, which is a challenge for control design. In stacked low-inertia converters (SLIC), the low-inertia converter modules are stacked for MV applications, resulting in coupling between the modules and making the control more challenging. A new model predictive control method which can achieve deadbeat regulation on the dc link without weighting factors has been proposed to address this novel problem. This paper focuses on analyzing the condition of the low-inertia dc link up to 80% ripple, the robustness of the control under parameter mismatches, high-order terms, and important implementation issues such as model-based sampling and computation delay compensation. Significantly, the high-order terms are introduced because of the large dc-link ripple. These high-order terms are unique to the SLIC and negligible in conventional high-inertia converters. A discrete-time large-signal model is built to capture the dc-link’s nonlinear dynamics, and the eigenvalues of a small-signal Jacobian matrix are analyzed with Floquet theory to evaluate stability, using the modular soft-switching solid-state transformer (M-S4T) as an example of the SLIC. Simulation and experimental results of an MVDC M-S4T verify the analysis and the predictive control method. Finally, the general application of the predictive control to low-inertia converters is compared against a conventional PI controller using a reduced dc-link active-front-end (AFE) rectifier as an example.

14 SOLAR ENERGY↗

Consolidation of iodine-loaded Ag 0 -functionalized silica aerogel with HUP, HIP and SPS

The U.S. Department of Energy is currently investigating alternative sorbents for the removal and immobilization of radioiodine from the gas streams in a nuclear fuel reprocessing plant. One of these new sorbents, silver-functionalized silica aerogel (Ag 0 -aerogel), shows promise as a potential replacement for silver mordenite because of its high selectivity and sorption capacity for iodine. Moreover, a feasible consolidation of iodine-loaded Ag 0 -aerogel to a durable SiO 2 -based waste form makes this aerogel an attractive choice for sequestering radioiodine. The main purpose of the study reported here was to investigate consolidation of Ag 0 -aerogel powders with or without iodine and with or without sintering additives with hot uniaxial pressing (HUP), HIP, and SPS. The selected densified samples were analyzed with a helium gas pycnometer for apparent density, with the Archimedes method for open porosity and apparent density, with scanning electron microscopy and energy dispersive spectroscopy (SEM-EDS) for the extent of densification, macro- and microstructural changes, and distribution of individual elements, and with X-ray diffraction (XRD) for crystalline phases. To convert the iodine-loaded Ag 0 -silica aerogel to a waste form, rapid consolidation with HUP, HIP, and SPS at moderate temperatures and pressures yields a final waste form consisting of AgI particles encapsulated in fused silica. HUP-processing (1200°C for 30 min under 29 MPa pressure) of Ag 0 -aerogel loaded with 20.2 mass% of iodine provided a product with residual open porosity of 16.9%. However, ~93% of sorbed iodine was retained in the sintered material. Densification with HIP at 1200°C for 30 min under 207 MPa pressure resulted in a fully dense silica-based waste form of 3.3 $\times$ 10 3 kg/m 3 bulk density containing ~22 mass% of iodine. Iodine was retained in the form of nano- and micro-inclusions of AgI dispersed in the silica matrix. Additives were not needed to enhance sintering process as depicted from the lack of open porosity and 100% retention of iodine in the consolidated product. The future tests will tell whether additives such as raw silica aerogel or Ag 0 -aerogel are required for HIPing to produce a fully dense waste form from iodine-loaded Ag 0 -aerogel containing higher concentrations of captured iodine. SPS-processing of samples with or without iodine revealed a benefit of additive-enhanced sintering. The samples containing additives (raw silica aerogel, colloidal silica, and Ag 0 -aerogel) shrunk faster and at lower temperatures. In addition, additives significantly improved distribution of silver compounds in the fully densified products, considerably decreasing the number of micron-sized inclusions of AgI, Ag and Ag 2 S at the grain boundaries.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of Homogenization Treatment and Microalloying with Mn on the Microstructure and Hot Workability of AA6060 Aluminum Alloys

The effects of a homogenization treatment and microalloying with Mn on the evolution of the microstructure and hot workability of AA6060 aluminum alloys were investigated. Various homogenization treatments with temperatures ranging from 520 to 610 °C and soaking times from 2 to 16 h were conducted. The results revealed that β-AlFeSi intermetallic was the dominant phase in the as-cast microstructure of the experimental alloys. During the homogenization, the fragmentation of intermetallics occurred and plate-like β-AlFeSi transformed into rod-like α-AlFeSi. In addition, a number of dispersoids precipitated in the 0.1Mn alloy in the temperature range of 520-580 °C. The flow stress behavior of the homogenized AA6060 alloys was mainly determined by the solid solution level. Increasing homogenization temperatures resulted in higher flow stresses owing to the increase in solute atoms in the aluminum matrix. The incremental Mn addition from 0 to 0.1% moderately increased the flow stress by up to 3%. Grain growth occurred in the alloys with low Mn contents (< 0.03Mn) during the high-temperature homogenization (580-610 °C), which resulted in a sudden decrease in the flow stresses and an irregular sample shape after the deformation. Microalloying with Mn (> 0.06%) can effectively prevent grain growth at such temperatures. For an alloy with Mn (0.1%) microalloying, homogenization at 550-580 °C for 6 h could be the optimal condition to balance the flow stress and desirable microstructure.

36 MATERIALS SCIENCE↗

MALDI MS Imaging at Acquisition Rates Exceeding 100 Pixels per Second

The practicality of matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) mass spectrometry (MS) applied to molecular imaging of biological tissues is limited by the analysis speed. Typically, a relatively low speed of stop-and-go micromotion of XY stages is considered as a factor substantially reducing the rate with which fresh sample material can be supplied to the laser spot. The sample scan rate in our laboratory-built high-throughput imaging TOF mass spectrometer was significantly improved through the use of a galvanometer-based optical scanner performing fast laser spot repositioning on a target plate. The optical system incorporated into the ion source of our MALDI TOF mass spectrometer allowed focusing the laser beam via a modified grid into a 10-μm round spot. This permitted the acquisition of high-resolution MS images with a well-defined pixel size at acquisition rates exceeding 100 pixel/s. The influence of selected parameters on the total MS imaging time is discussed. The new scanning technique was employed to display the distribution of an antitumor agent in 3D colorectal adenocarcinoma cell aggregates; a single MS image comprising 100 × 100 pixels with 10-μm lateral resolution was recorded in approximately 70 s. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of semivolatile organics in liquid radioactive residue using sorptive stir bar and solvent back-extraction

Current methods for semivolatiles analysis in radioactive samples can produce large volumes of radioactive solvent residue. A method utilizing stir-bar sorptive extraction has been explored in this work for its applicability to radioactive waste samples. This low solvent analytical method may accelerate remediation, minimize hazardous solvent waste, and reduce exposure risk to workers. Organic compounds (polyaromatic hydrocarbons, chlorinated aromatics, and phenolic compounds) were chosen as surrogates for common Liquid Waste System (LWS) contaminants at Savannah River Site (Aiken, SC). Stir-bar extraction parameters (extraction time, matrix modification, and effective pH range) and solvent back extraction parameters (solvent type, volume, and extraction time) were optimized experimentally for the chosen compounds. Affinity of the stir-bar extraction polymer to radionuclides Cs-137 and Am-241 was observed to determine radionuclide concentration effects. The stir-bar method achieved mean recovery of 100 ± 0.7% (1σ), relative to 114 ± 7% using solvent extraction, while reducing weekly method hands-on time by 93.4% and solvent volume consumption by 99.3%. Sensitivity was improved by 378% in simulated tank waste and 278% in real-world LWS matrix, relative to solvent extraction. This work has produced a safe and optimized method for the low solvent analysis of organics in legacy radioactive tank waste by stir-bar sorptive extraction.

GC-MS↗

Geochemical and Geomechanical Effects on Wellbore Cement Fractures

Experimental studies were conducted using batch reactors, X-ray microtomograpy (XMT), and computational fluid dynamics (CFD) simulation to determine changes in cement fracture surfaces, fluid flow pathways, and permeability with geochemical and geomechanical processes. Composite Portland cement-basalt caprock core with artificial fractures was prepared and reacted with CO2-saturated groundwater at 50°C and 10 MPa for 3 to 3.5 months under static conditions to understand the geochemical and geomechanical effects on the integrity of wellbores containing defects. Cement-basalt interface samples were subjected to mechanical stress at 2.7 MPa before the CO2 reaction. XMT provided three-dimensional (3-D) visualization of the opening and interconnection of cement fractures due to mechanical stress. After the CO2 reaction, XMT images revealed that calcium carbonate precipitation occurred extensively within the fractures in the cement matrix, but only partially along fractures located at the cement-basalt interface. The permeability calculated based on CFD simulation was in agreement with the experimentally measured permeability. The experimental results imply that the wellbore cement with fractures is likely to be healed during exposure to CO2-saturated groundwater under static conditions, whereas fractures along the cement-caprock interface are still likely to remain vulnerable to the leakage of CO2. CFD simulation for the flow of different fluids (CO2-saturated brine and supercritical CO2) using a pressure difference of 20 kPa and 200 kPa along ~2 cm-long cement fractures showed that a pressure gradient increase resulted in an increase of CO2 fluids flux by a factor of only ~3-9 because the friction of CO2 fluids on cement fracture surfaces increased with higher flow rate as well. At the same pressure gradient, the simulated flow rate was higher for supercritical CO2 than CO2-saturated brine by a factor of only ~2-3, because the viscosity of supercritical CO2 is much lower than that of CO2-saturated brine. The study suggests that in deep geological reservoirs the geochemical and geomechanical processes have coupled effects on the wellbore cement fracture evolution and fluid flow along the fracture surfaces.

36 MATERIALS SCIENCE↗

A Physically-Based Model for Thermo-Oxidative and Hydrolytic Aging of Elastomers

A computationally efficient model is proposed to capture the loss of mechanical performance due to chemical aging that are formed as the competition of chain scission and cross-link formation/dissolution, such as thermo-oxidative aging or hydrolytic aging. The model should be considered an extension of our recent models [1, 2, 3] which further simplifies the matrix behavior based on the assumption of independence of environmental and mechanical damage. The model uses this assumption to reduce the necessary material parameters needed to model constitutive and inelastic behavior of elastomers during aging. To this end, the model can provide accurate predictions of the material performance with the significantly fewer number of fitting parameters. The model is relevant for all decay mechanisms formed by the occurrence of two simultaneous micro-mechanisms; (i) formation/reduction of the cross-links, and (ii) chain scission, both of which are present in thermo-oxidation and hydrolytic aging. Assuming the alteration of the chain density along the aging trajectory is identical to the peroxide cross-link density for thermo-oxidation, and the change of the average molecular weight for hydrolysis, the strain energy of polymer matrix can be rewritten as a function of deformation, deformation history, storage time and aging temperature. Next, the modified network alteration model is formulated for implementation into Finite Element (FE) simulations. The model is built on the presumption of homogeneous and consistent oxygen/water absorption and thus is mainly relevant for relatively thin samples exposed to environmental loads for a long time. The proposed model includes only six physically inspired material parameters. Therefore, while it is computationally efficient, it shows good agreement with own experimental data, which performed on various range of accelerated aging temperatures and times. With respect to its computational efficiency, simplicity, accuracy, and interpret-ability, the model is the right choice for advanced implementations in FE programs.

42 ENGINEERING↗

Stability of SiC and its Composites at High Neutron Fluence

High purity chemically vapor-deposited (CVD) silicon carbide (SiC) and near-stoichiometric SiC fiber, chemically vapor-infiltrated (CVI) SiC matrix composite were evaluated following neutron irradiation to {approx}28 dpa at 300 and 650 C and to {approx}41 dpa at 800 C, respectively. The irradiated swelling, thermal conductivity, and elastic modulus indicated no additional changes in these properties at high fluences after saturation at low fluences. With a statistically meaningful sample population, no change in flexural strength of CVD SiC was observed after 300 C irradiation. A slight decrease in strength was observed after 650 C irradiation but was attributed to an experimental artifact; specifically, a reaction between samples and the capsule components. The Hi-Nicalon{trademark} Type-S, CVI SiC composite retained the pre-irradiation strength and the non-linear fracture mode. The electrical resistivity measurement revealed a relatively minor effect of irradiation. Overall, irradiation-insensitivity of the high purity SiC ceramics and composite to neutron irradiation to doses 30-40 dpa at temperatures 300-800 C was demonstrated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

In situ formation of tin nanocrystals embedded in silicon nitride matrix

Tin (Sn) nanocrystals (NCs) embedded in a silicon nitride (Si{sub 3}N{sub 4}) matrix have been fabricated in a cosputtering process employing low temperature (100 deg. C) substrate heating. Transmission electron microscopy (TEM) showed the formation of uniformly sized Sn NCs of 5.2+-0.9 nm evenly distributed in the Si{sub 3}N{sub 4} matrix. Both TEM and x-ray diffraction measurements showed that the Sn NCs adopted the semimetallic tetragonal beta-Sn structure rather than the cubic semiconducting alpha-Sn structure. X-ray photoelectron spectroscopy revealed that the semimetallic state (Sn{sup 0}) is the major component of Sn in the sample films. Our investigation demonstrates a pronounced effect of the substrate temperature on the formation of Sn NCs. The mechanism of in situ formation of Sn NCs is discussed. We suggest that the formation of uniformly sized Sn NCs is correlated with lowering the surface mobility of the nuclei due to the presence of the cosputtered Si{sub 3}N{sub 4}.

77 NANOSCIENCE AND NANOTECHNOLOGY↗