Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Investigations on the multiple-sector hard-copper X-band accelerating structures

The development of advanced, high gradient accelerating structures is one of the leading activity of the particle accelerator community. In the technological research of new construction methods for these devices, high-power testing is a critical step for the verification of their viability. Recent experiments showed that accelerating cavities made out of hard copper, fabricated without high-temperature processes, can achieve better performance as compared with soft copper ones. Recently, we have built cavities using Tungsten Inert Gas welding and the high-power experiments confirmed that this joining process is a robust and low-cost alternative to brazing or diffusion bonding. This is a good solution for high-gradient operation, with a gradient of about 150 MV/m in X-band, at a breakdown rate of 10 -3 /pulse/meter using a shaped RF pulse with a 150 ns flat part. We continue the design, construction and high power tests of three-cells standing-wave X-band accelerating cavities fabricated with a split-open geometry, made of hard copper and vacuum-sealed by welding. Our aim is the fabrication of accelerating structures made out of hard copper alloys by using innovative cost-effective technologies. Moreover, our method of multiple-sector structures opens the way to new technological approaches and design methods, for example providing the possibility of placing dampers of the parasitic higher-order modes. Such structures with dampers allow for acceleration of multi-bunch beams, both in standing and in travelling-wave accelerating modality. Here, this paper describes the design of two cavities made of multiple sectors that were fabricated at the Italian Institute for Nuclear Physics in Frascati, Italy (INFN-LNF), assembled by means of clamping and then joined with the Tungsten Inert Gas welding in order to preserve the hardness of the metal. These are three-cell standing-wave X-band accelerating cavities, to be operated in the π-mode. We report the low-power RF tests of the first one, made of two halves, and the RF design of the second one, made of four quadrants. Both structures were built for high-gradient tests at SLAC National Accelerator Laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mirror instability and origin of morningside auroral structure

Auroral optical imagery shows marked differences between auroral features of the evening and morning sectors: the separation between diffuse and discrete auroras in the evening sector is not distinct in the morning sector, which is dominated by auroral patches and multiple banded structures aligned along some direction. Plasma distribution function signatures also show marked differences: downward electron beams and inverted-V signatures prefer the evening sector, while the electron spectra on the morning sector are similar to the diffuse aurora. A theory of morningside auroras consistent with these features was constructed. The theory is based on modulation of the growth rates of electron cyclotron waves by the mirror instability, which is in turn driven by inward-convected ions that have become anisotropic. This modulation produces alternating bands of enhanced and reduced electron precipitation which approximate the observed multiple auroral bands and patches of the morning sector.

Chiu, Y. T.↗

Status of the ANNIE experiment

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a Gadolinium-loaded water Cherenkov detector located in the Booster Neutrino Beam at Fermilab. One of its primary physics goals is to measure the final state neutron multiplicity of neutrino-nucleus interactions. This measurement of the neutron yield as a function of the outgoing lepton kinematics will be useful to constrain systematic uncertainties and reduce biases in future long-baseline oscillation and cross-section experiments. ANNIE is also a testbed for innovative new detection technologies. It will make use of pioneering photodetectors called Large Area Picosecond Photodetectors (LAPPDs) with better than 100 picosecond time resolution, which will enhance its reconstruction capabilities and demonstrate the feasibility of this technology as a new tool in high energy physics. The status of the experiment is reported here in terms of the overall progress, the deployment of the first LAPPD and an overview of recently taken beam and calibration data. Additional future R\&D efforts and analysis opportunities involving the use of the novel detection medium of Water-based Liquid Scintillators (WbLS) are also briefly highlighted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam energy dependence of net- Λ fluctuations measured by the STAR experiment at the BNL Relativistic Heavy Ion Collider

The measurements of particle multiplicity distributions have generated considerable interest in understanding the fluctuations of conserved quantum numbers in the quantum chromodynamics (QCD) hadronization regime, in particular near a possible critical point and near the chemical freeze-out. Net-protons and net-kaons have been used as proxies for the net-baryon number and net-strangeness, respectively. We report the measurement of efficiency- and centrality-bin width-corrected cumulant ratios (C 2 /C 1 , C 3 /C 2 ) of net- Λ distributions, in the context of both strangeness and baryon number conservation, as a function of collision energy, centrality, and rapidity. The results are for Au + Au collisions at five beam energies ( √s NN = 19.6 , 27, 39, 62.4, and 200 GeV) recorded with the Solenoidal Tracker at RHIC (STAR). We compare our results to the Poisson and negative binomial (NBD) expectations, as well as to ultrarelativistic quantum molecular dynamics (UrQMD) and hadron resonance gas (HRG) model predictions. Both NBD and Poisson baselines agree with data within the statistical and systematic uncertainties. UrQMD describes the measured net- Λ C 1 and C 3 at 200 GeV reasonably well but deviates from C 2 , and the deviation increases as a function of collision energy. The ratios of the measured cumulants show no features of critical fluctuations. The chemical freeze-out temperatures extracted from a recent HRG calculation, which was successfully used to describe the net-proton, net-kaon, and net-charge data, indicate Λ freeze-out conditions similar to those of kaons. However, large deviations are found when comparing with temperatures obtained from net-proton fluctuations. The net- Λ cumulants show a weak but finite dependence on the rapidity coverage in the acceptance of the detector, which can be attributed to quantum number conservation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Commissioning of the EBIS-based heavy ion preinjector at Brookhaven

The status is presented of the commissioning of a new heavy ion preinjector at Brookhaven National Laboratory. This preinjector uses an Electron Beam Ion Source (EBIS), and an RFQ and IH Linac, both operating at 100.625 MHz, to produce 2 MeV/u ions of any species for use, after further acceleration, at the Relativistic Heavy Ion Collider (RHIC) and the NASA Space Radiation Laboratory (NSRL). Among the increased capabilities provided by this preinjector are the ability to produce ions of any species, and the ability to switch between multiple species in 1 second, to simultaneously meet the needs of both science programs. For initial setup, helium beam from EBIS was injected and circulated in the Booster synchrotron. Following this, accelerated Au{sup 32+} and Fe{sup 20+} beams were transported to the Booster injection point, fulfilling DOE requirements for project completion.

43 PARTICLE ACCELERATORS↗

Laser-driven relativistic electron beam interaction with solid dielectric

The multi-frames shadowgraphy, interferometry and polarimetry diagnostics with sub-ps time resolution were used for an investigation of ionization wave dynamics inside a glass target induced by laser-driven relativistic electron beam. Experiments were done using the 50 TW Leopard laser at the UNR. For a laser flux of {approx}2 Multiplication-Sign 10{sup 18}W/cm{sup 2} a hemispherical ionization wave propagates at c/3. The maximum of the electron density inside the glass target is {approx}2 Multiplication-Sign 10{sup 19}cm{sup -3}. Magnetic and electric fields are less than {approx}15 kG and {approx}1 MV/cm, respectively. The electron temperature has a maximum of {approx}0.5 eV. 2D interference phase shift shows the 'fountain effect' of electron beam. The very low ionization inside glass target {approx}0.1% suggests a fast recombination at the sub-ps time scale. 2D PIC-simulations demonstrate radial spreading of fast electrons by self-consistent electrostatic fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mirror instability and the origin of morningside auroral structure

Auroral optical imagery shows marked differences between auroral features of the evening and morning sectors: The separation between diffuse and discrete auroras in the evening sector is not distinct in the morning sector, which is dominated by auroral patches and multiple banded structures aligned along some direction. Plasma distribution function signatures also show marked differences: downward electron beams and inverted-V signatures prefer the evening sector, while the electron spectra on the morning sector are similar to the diffuse aurora. We have constructed a theory of morningside auroras consistent with these features. The theory is based on modulation of the growth rates of electron cyclotron waves by the mirror instability, which is in turn driven by inward-convected ions that have become anisotropic. This modulation produces alternating bands of enhanced and reduced electron precipitation which approximate the observed multiple auroral bands and patches of the morning sector.

Chiu, Y. T.↗

SU-F-E-13: Design and Fabrication of Gynacological Brachytherapy Shielding & Non Shielding Applicators Using Indigenously Developed 3D Printing Machine

Purpose: In this innovative work we have developed Gynecological Brachytherapy shielding & Non Shielding Applicators and compared with the commercially available applicators by using the indigenously developed 3D Printing machine. Methods: We have successfully indigenously developed the 3D printing machine. Which contain the 3 dimensional motion platform, Heater unit, base plate, ect… To fabricate the Gynecological Brachytherapy shielding & non shielding applicators the 3D design were developed in the computer as virtual design. This virtual design is made in a CAD computer file using a 3D modeling program. Separate programme for the shielding & non shielding applicators. We have also provided the extra catheter insert provision in the applicator for the multiple catheter. The DICOM file of the applicator were then converted to stereo Lithography file for the 3D printer. The shielding & Non Shielding Applicators were printed on a indigenously developed 3D printer material. The same dimensions were used to develop the applicators in the acrylic material also for the comparative study. A CT scan was performed to establish an infill-density calibration curve as well as characterize the quality of the print such as uniformity and the infill pattern. To commission the process, basic CT and dose properties of the printing materials were measured in photon beams and compared against water and soft tissue. Applicator were then scanned to confirm the placement of multiple catheter position. Finally dose distributions with rescanned CTs were compared with those computer-generated applicators. Results: The doses measured from the ion Chamber and X-Omat film test were within 2%. The shielded applicator reduce the rectal dose comparatively with the non shielded applicator. Conclusion: As of submission 3 unique cylinders have been designed, printed, and tested dosimetrically. A standardizable workflow for commissioning custom 3D printed applicators was codified and will be reported.

60 APPLIED LIFE SCIENCES↗

O-Mode Instability for Non-Thermal Continuum Radiation Generated Near the Plasmapause

Analysis of the ordinary mode (O-mode) instability is performed to comprehend the nonthermal continuum (NTC) radiation near the plasmapause, taking into account the relativistic wave-electron resonance effect. The energy source is the anisotropy in the velocity of the minority suprathermal electron population. Numerical solutions demonstrate that the O-mode can be unstable with multiple narrow frequency bands located close to harmonics of the electron cyclotron frequency above the local electron plasma frequency. These waves have narrow beaming angle bands of nearly 90° relative to the ambient magnetic field. Our findings indicate that NTC radiation generated by this wave-electron resonance instability near the plasmapause can propagate nearer to the magnetic equator with multiple harmonics, which is in agreement with a recent statistical study using Van Allen Probes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Poster — Thur Eve — 15: Improvements in the stability of the tomotherapy imaging beam

Use of helical TomoTherapy based MVCT imaging for adaptive planning requires the image values (HU) to remain stable over the course of treatment. In the past, the image value stability was suboptimal, which required frequent change to the image value to density calibration curve to avoid dose errors on the order of 2–4%. The stability of the image values at our center was recently improved by stabilizing the dose rate of the machine (dose control servo) and performing daily MVCT calibration corrections. In this work, we quantify the stability of the image values over treatment time by comparing patient treatment image density derived using MVCT and KVCT. The analysis includes 1) MVCT - KVCT density difference histogram, 2) MVCT vs KVCT density spectrum, 3) multiple average profile density comparison and 4) density difference in homogeneous locations. Over two months, the imaging beam stability was compromised several times due to a combination of target wobbling, spectral calibration, target change and magnetron issues. The stability of the image values were analyzed over the same period. Results show that the impact on the patient dose calculation is 0.7% +− 0.6%.

60 APPLIED LIFE SCIENCES↗

Quasioptical modeling of wave beams with and without mode conversion: II. Numerical simulations of single-mode beams

This work continues a series of papers where we propose an algorithm for quasioptical modeling of electromagnetic beams with and without mode conversion. The general theory was reported in the first paper of this series, where a parabolic partial differential equation was derived for the field envelope that may contain one or multiple modes with close group velocities. Here, we present a corresponding code PARADE (PAraxial RAy DEscription) and its test applications to single-mode beams in vacuum and also in inhomogeneous magnetized plasma. The numerical results are compared, respectively, with analytic formulas from Gaussian-beam optics and also with cold-plasma ray tracing. Quasioptical simulations of mode-converting beams are reported in the next, third paper of this series.

ECRH↗

SpaRibs Geometry Parameterization for Wings with Multiple Sections using Single Design

The SpaRibs topology of an aircraft wing has a significant effect on its structural behavior and stability as well as the flutter performance. The development of additive manufacturing techniques like Electron Beam Free Form Fabrication (EBF3) has made it feasible to manufacture aircraft wings with curvilinear spars, ribs (SpaRibs) and stiffeners. In this article a new global-local optimization framework for wing with multiple sections using curvilinear SpaRibs is described. A single design space is used to parameterize the SpaRibs geometry. This method has been implemented using MSC-PATRAN to create a broad range of SpaRibs topologies using limited number of parameters. It ensures C0 and C1 continuities in SpaRibs geometry at the junction of two wing sections with airfoil thickness gradient discontinuity as well as mesh continuity between all structural components. This method is advantageous in complex multi-disciplinary optimization due to its potential to reduce the number of design variables. For the global-local optimization the local panels are generated by an algorithm which is totally based on a set algebra on the connectivity matrix data. The great advantage of this method is that it is completely independent of the coordinates of the nodes of the finite element model. It is also independent of the order in which the elements are distributed in the FEM. The code is verified by optimizing of the CRM Baseline model at trim condition at Mach number equal to 0.85 for five different angle of attack (-2deg, 0deg,2deg,4deg and 6deg). The final weight of the wing is 19,090.61 lb. This value is comparable to that obtained by Qiang et al. 6 (19,269 lb).

wing sections↗

Manipulating ferroelectric behaviors via electron-beam induced crystalline defects

Ferroelectric nanoplates are attractive for applications in nanoelectronic devices. Defect engineering has been an effective way to control and manipulate ferroelectric properties in nanoscale devices. Defects can act as pinning centers for ferroelectric domain wall motion, altering the switching properties and domain dynamics of ferroelectrics. However, there is a lack of detailed investigation on the interactions between defects and domain walls in ferroelectric nanoplates due to the limitation of previous characterization techniques, which impedes the development of defect engineering in ferroelectric nanodevices. In this study, we applied in situ biasing transmission electron microscopy to explore how dislocation loops, which were judiciously introduced into barium titanate nanoplates via electron beam irradiation, affect the motion of ferroelectric domain walls. The results show that the motion was dramatically suppressed by these localized defects, because of the local strain fields induced by the defects. Additionally, the pinning effect can be further enhanced by multiple domain walls embedded with defect arrays. These results indicate the possibility of manipulating domain switching in ferroelectric nanoplates via the electron beam.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The LAMP instrument at the Linac Coherent Light Source free-electron laser

The Laser Applications in Materials Processing (LAMP) instrument is a new end-station for soft X-ray imaging, high-field physics, and ultrafast X-ray science experiments that is available to users at the Linac Coherent Light Source (LCLS) free-electron laser. While the instrument resides in the Atomic, Molecular and Optical science hutch, its components can be used at any LCLS beamline. The end-station has a modular design that provides high flexibility in order to meet user-defined experimental requirements and specifications. The ultra-high-vacuum environment supports different sample delivery systems, including pulsed and continuous atomic, molecular, and cluster jets; liquid and aerosols jets; and effusive metal vapor beams. It also houses movable, large-format, high-speed pnCCD X-ray detectors for detecting scattered and fluorescent photons. Multiple charged-particle spectrometer options are compatible with the LAMP chamber, including a double-sided spectrometer for simultaneous and even coincident measurements of electrons, ions, and photons produced by the interaction of the high-intensity X-ray beam with the various samples. Here in this paper we describe the design and capabilities of the spectrometers along with some general aspects of the LAMP chamber and show some results from the initial instrument commissioning.

47 OTHER INSTRUMENTATION↗

Compact steady-state and high-flux Falcon ion source for tests of plasma-facing materials

This paper describes the design and operation of the Falcon ion source. It is based on conventional design of anode layer thrusters. This ion source is a versatile, compact, affordable, and highly functional in the research field of the fusion materials. The reversed magnetic field configuration of the source allows precise focusing of the ion beam into small spot of Almost-Equal-To 3 mm and also provides the limited capabilities for impurity mass-separation. As the result, the source generates steady-state ion beam, which irradiates surface with high heat (0.3 - 21 MW m{sup -2}) and particle fluxes (4 Multiplication-Sign 10{sup 21}- 3 Multiplication-Sign 10{sup 23} m{sup -2}s{sup -1}), which approaches the upper limit for the flux range expected in ITER.

43 PARTICLE ACCELERATORS↗

SU-F-T-458: Tracking Trends of TG-142 Parameters Via Analysis of Data Recorded by 2D Chamber Array

Purpose: With increasing QA demands of medical physicists in clinical radiation oncology, the need for an effective method of tracking clinical data has become paramount. A tool was produced which scans through data automatically recorded by a 2D chamber array and extracts relevant information recommended by TG-142. Using this extracted information a timely and comprehensive analysis of QA parameters can be easily performed enabling efficient monthly checks on multiple linear accelerators simultaneously. Methods: A PTW STARCHECK chamber array was used to record several months of beam outputs from two Varian 2100 series linear accelerators and a Varian NovalisTx−. In conjunction with the chamber array, a beam quality phantom was used to simultaneously to determine beam quality. A minimalist GUI was created in MatLab that allows a user to set the file path of the data for each modality to be analyzed. These file paths are recorded to a MatLab structure and then subsequently accessed by a script written in Python (version 3.5.1) which then extracts values required to perform monthly checks as outlined by recommendations from TG-142. The script incorporates calculations to determine if the values recorded by the chamber array fall within an acceptable threshold. Results: Values obtained by the script are written to a spreadsheet where results can be easily viewed and annotated with a “pass” or “fail” and saved for further analysis. In addition to creating a new scheme for reviewing monthly checks, this application allows for able to succinctly store data for follow up analysis. Conclusion: By utilizing this tool, parameters recommended by TG-142 for multiple linear accelerators can be rapidly obtained and analyzed which can be used for evaluation of monthly checks.

61 RADIATION PROTECTION AND DOSIMETRY↗

Electron Impact Excitation Cross Section Measurement for n=3 to n=2 Line Emission in Fe(17+) to Fe(23+)

We have measured the electron impact excitation cross sections for the strong iron L-shell 3 --> 2 lines of Fe XVIII to Fe XXIV at the EBIT-I electron beam ion trap using a crystal spectrometer and NASA-Goddard Space Flight Centers 6 x 6 pixel array microcalorimeter. The cross sections were determined by direct normalization to the well established cross section of radiative electron capture through a sophisticated model analysis which results in the excitation cross section for the strong Fe L-shell lines at multiple electron energies. This measurement is part of a laboratory X-ray astrophysics program utilizing the Livermore electron beam ion traps EBIT-I and EBIT-II.

Chen, H.↗

Microfocus/Polycapillary-Optic Crystallographic X-Ray System

A system that generates an intense, nearly collimated, nearly monochromatic, small-diameter x-ray beam has been developed for use in macromolecular crystallography. A conventional x-ray system for macromolecular crystallography includes a rotating-anode x-ray source, which is massive (.500 kg), large (approximately 2 by 2 by 1 m), and power-hungry (between 2 and 18 kW). In contrast, the present system generates a beam of the required brightness from a microfocus source, which is small and light enough to be mounted on a laboratory bench, and operates at a power level of only tens of watts. The figure schematically depicts the system as configured for observing x-ray diffraction from a macromolecular crystal. In addition to the microfocus x-ray source, the system includes a polycapillary optic . a monolithic block (typically a bundle of fused glass tubes) that contains thousands of straight or gently curved capillary channels, along which x-rays propagate with multiple reflections. This particular polycapillary optic is configured to act as a collimator; the x-ray beam that emerges from its output face consists of quasi-parallel subbeams with a small angular divergence and a diameter comparable to the size of a crystal to be studied. The gap between the microfocus x-ray source and the input face of the polycapillary optic is chosen consistently with the focal length of the polycapillary optic and the need to maximize the solid angle subtended by the optic in order to maximize the collimated x-ray flux. The spectrum from the source contains a significant component of Cu K (photon energy is 8.08 keV) radiation. The beam is monochromatized (for Cu K ) by a nickel filter 10 m thick. In a test, this system was operated at a power of 40 W (current of 897 A at an accelerating potential of 45 kV), with an anode x-ray spot size of 41+/-2 microns. Also tested, in order to provide a standard for comparison, was a commercial rotating-anode x-ray crystallographic system with a pyrolytic graphite monochromator and a 250-micron pinhole collimator, operating at a power of 3.15 kW (current of 70 mA at an accelerating potential of 45 kV). The flux of collimated Cu K radiation in this system was found to be approximately 16 times that in the rotatinganode system. Data on x-ray diffraction from crystals of tetragonal form of lysozyme (protein) in this system were found to be of high quality and to be reducible by use of standard crystallographic software.

Joy, Marshall↗