Search NASA⌕ Search

SEARCH · Search NASA

Results for “quality monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Multi-Decadal Nitrogen Dioxide and Derived Products from Satellites (MINDS) Datasets Released by NASA GES DISC and Their Applications for Air Quality

Nitrogen dioxide (NO2), a pervasive air pollutant, comes from vehicles, power plants, industrial emissions, and off-road sources such as construction or lawn and gardening equipment. The NASA Goddard Earth Sciences Data and Information Services Center (GES DISC) curates many remote sensing datasets with NO2 retrievals, which have been utilized for air quality research and applications. The remotely-sensed datasets include those generated by the Ozone Monitoring Instrument (OMI) on the Aura satellite, the TROPOspheric Monitoring Instrument (TROPOMI) onboard the Copernicus Sentinel-5 Precursor (S5P), and the Ozone Mapping and Profiling Suite (OMPS) Nadir-Mapper (NM) instrument on the Suomi National Polar-orbiting Partnership (S- NPP). In collaboration with the NASA Making Earth System Data Records for Use in Research Environments (MEaSUREs) Multi-Decadal Nitrogen Dioxide and Derived Products from Satellites (MINDS) project, the GES DISC recently released MINDS datasets. The NASA MEaSUREs MINDS project aims to develop long-term NO2 global data records by adapting a consistent retrieval algorithm to multiple instrument measurements. Long-term data records will be achieved by applying consistent retrieval approaches to multiple satellite instruments, including OMI (2004 - ); the Global Ozone Monitoring Experiment (GOME, 1995-2011) onboard the second European Remote Sensing satellite (ERS-2); the Scanning Imaging Spectrometer for Atmospheric Cartography (SCIAMACHY, 2002-2012) onboard the ENVIronmental SATellite (ENVISAT); GOME-2 on the Meteorological Operational satellites (MetOp-A and MetOp-B, 2006 - ); and TROPOMI onboard the Copernicus S5P (2017 - ). The long-term record (1995 to present) of MINDS datasets makes them very useful for air quality trend studies. Some MINDS datasets with high spatial resolution of only a few kilometers can be used for air quality research and applications at regional scales. In this presentation, we will introduce all of the MINDS products and services, and demonstrate use cases of MINDS data for studying air quality. We will also present a few other NO2 datasets acquired from NASA’s Health and Air Quality Applied Sciences Team (HAQAST), to be archived and distributed by the GES DISC, and highlight some of their applications for air quality and health.

Feng Ding↗

Analysis of Ethanolamines: Validation of Semi-Volatile Analysis by HPLC-MS/MS by EPA Method MS888

The Environmental Protection Agency's (EPA) Region 5 Chicago Regional Laboratory (CRL) developed a method titled 'Analysis of Diethanolamine, Triethanolamine, n-Methyldiethanolamine, and n-Ethyldiethanolamine in Water by Single Reaction Monitoring Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS): EPA Method MS888'. This draft standard operating procedure (SOP) was distributed to multiple EPA laboratories and to Lawrence Livermore National Laboratory, which was tasked to serve as a reference laboratory for EPA's Environmental Reference Laboratory Network (ERLN) and to develop and validate analytical procedures. The primary objective of this study was to validate and verify the analytical procedures described in 'EPA Method MS888' for analysis of the listed ethanolamines in aqueous samples. The gathered data from this validation study will be used to: (1) demonstrate analytical method performance; (2) generate quality control acceptance criteria; and (3) revise the SOP to provide a validated method that would be available for use during a homeland security event. The data contained in this report will be compiled, by EPA CRL, with data generated by other EPA Regional laboratories so that performance metrics of 'EPA Method MS888' can be determined.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-F-207-14: Low Contrast Detectability (LCD) at Different Diagnostic Reference Levels for Adult Abdominal CT Procedures

Purpose Using diagnostic reference levels (DRL) to optimize CT protocols has potential to reduce radiation dose and meet regulatory requirements. However, DRL’s tend to be misconstrued as dose limits, are typically designed for specific patient populations, and are assumed to have acceptable image quality (AIQ) associated with them. To determine the image quality that is associated with established DRL’s for adult abdominal CT studies, a LCD phantom study was employed. Methods: A CT phantom (CIRS) containing three columns of 7 spherical targets, ranging from 10mm to 2.4 mm, that are 5, 10, and 20 HU below the background (HUBB) matrix was scanned with a GE HD750 64 slice scanner. The phantom was scanned at the NEXT 2006 25th CTDIvol of 12 mGy, the NCRP 172 achievable dose (AD) CTDIvol of 17 mGy and 75th CTDIvol of 25 mGy and at the ACR recommended CTDIvol of 25 mGy. It was also scanned at a CTDIvol 20% greater than the AD at 20 mGy and the ACR maximum threshold of 30 mGy. Results: At the NEXT 2006 25th percentile CTDIvol of 12 mGy, a 6.3 mm low contrast lesion was detectable in the 20 HUBB; 6.3 mm in the 10 HUBB and 10 mm in the 5 HUBB column. Increasing the CTDIvol to the NCRP 172 AD of 17 mGy, an additional 4.8 mm lesion was visualized in the 20 HUBB column. At 20 mGy, an additional 4.8 mm lesion was detectable in the 10 HUBB column. No further lesions were visible between 20 and 30 mGy. However, conspicuity of all lesions increased with each additional step up in CTDI. Conclusion: Optimizing radiation dose to achieve AIQ is a critical aspect of any dose optimization committee. Hence, judicious monitoring of radiation exposure to patients has to be balanced with diagnostic image quality.

60 APPLIED LIFE SCIENCES↗

How Well Satellite Remote Sensing Can Inform Surface Level Ozone Production Sensitivity to Precursor Trace Gas Emissions?

Surface-level ozone (O3) pollution mitigation strategies rely on a clear understanding of the atmospheric chemical processes involving O3, NOx (nitric oxide (NO) + nitrogen dioxide (NO2)) and volatile organic compounds (VOCs). A robust spatiotemporal classification of O3 photochemical regimes with relative chemical sensitivity of local O3 formation to emission reductions of NOx (NOx-limited regime) versus VOCs (radical-limited regime) is required to design anthropogenic emission reduction policies in order to improve surface air quality. Numerous studies found that the ratio of satellite-retrieved Vertical Column Densities (VCDs) of formaldehyde (HCHO) to NO2 can diagnose O3 production sensitivity. However, uncertainty still remains about the accuracy of such estimates using satellite-based retrievals. This study conducts an investigation to identify how well satellite data can inform surface-level O3 sensitivity by validating satellite-based estimates against aircraft-based retrievals taken during the Long Island Sound Tropospheric Ozone Study (LISTOS-2018) and Ozone Water-Land Environmental Transition Study (OWLETS-2) field campaigns. For this study, we use HCHO and NO2 retrievals from the Ozone Monitoring Instrument (OMI) onboard the Aura satellite, and high spatiotemporal resolution TROPOspheric Monitoring Instrument (TROPOMI) onboard the Sentinel-5 Precursor (S5P) satellite. The Community Multiscale Air Quality (CMAQ) modelling system is used to provide trace gas vertical profiles to recalculate air mass factor for deriving consistent satellite-based VCDs. To demonstrate the ability of satellites to diagnose O3 production regimes, we validate satellite-derived O3 sensitivity regimes, along with the OMI and TROPOMI products applied, using HCHO and NO2 retrievals from the aircraft-based instruments: Geostationary Trace gas and Aerosol Sensor Optimization (GeoTASO) spectrometer and Geostationary Coastal and Air Pollution Events Airborne Simulator (GCAS) instruments deployed during the LISTOS-2018 and OWLETS-2 campaigns. The results of this work will advance our fundamental knowledge of the spatiotemporal evolution of the complex O3-NOx-VOC chemistry, and will advance our understanding about the quality of remote-sensing, suborbital, and satellite data for accurately observing surface-level O3 production sensitivity.

Satellite↗

Analysis and quality control of carbohydrates in therapeutic proteins with fluorescence HPLC

Conbercept is an Fc fusion protein with very complicated carbohydrate profiles which must be carefully monitored through manufacturing process. Here, we introduce an optimized fluorescence derivatization high-performance liquid chromatographic method for glycan mapping in conbercept. Compared with conventional glycan analysis method, this method has much better resolution and higher reproducibility making it excellent for product quality control.

60 APPLIED LIFE SCIENCES↗

Investigating the Spatial and Temporal Limitations for Remote Sensing of Wildfire Smoke Using Satellite and Airborne Imagers During FIREX_AQ

Starting from point sources, wildfire smoke is important in the global aerosol system. The ability to characterize smoke near-source is key to modeling smoke dispersion and predicting air quality. With hemispheric views and 10-min refresh, imagers in Geostationary (GEO) orbit have advantages monitoring smoke over once-per-day sensors in low-earth orbit (LEO). However, both can be inadequate in capturing the characteristics of smoke plumes close to their sources due to too-coarse spatial resolution (both detector and product resolution), too-sparse temporal resolution (from LEO sensors), and too-conservative masking. In addition to satellite observations, the Fire Influence on Regional to Global Environments and Air Quality experiment offered sub-orbital enhanced-MODIS Airborne Simulator (eMAS) imagery at 50 m pixel resolution—including multiple eMAS flight tracks over individual fires in short time periods. It provided opportunity to explore smoke plume characterization at various spatial and temporal scales and quantify the limitations of space sensors for describing smoke magnitude near source as well as its temporal evolution. Here we applied modified aerosol algorithm to different imagers, relaxing its masking to estimate smoke's aerosol optical depth (AOD) as close as possible to its source. We found that GEO sensors with nominal 1 km spatial resolution can match the much finer resolution eMAS retrieved mean plume AOD, as long as the retrieval spatial resolution is finer than the width of the plumes. However, the plume's maximum AOD may be drastically underestimated by satellite products.

remote sensing↗

Characterization of the Li beam probe with a beam profile monitor on JET

The lithium beam probe (LBP) is widely used for measurements of the electron density in the edge plasma of magnetically confined fusion experiments. The quality of LBP data strongly depends on the stability and profile shape of the beam. The main beam parameters are as follows: beam energy, beam intensity, beam profile, beam divergence, and the neutralization efficiency. For improved monitoring of the beam parameters, a beam profile monitor (BPM) from the National Electrostatics Corporation (NEC) has been installed in the Li beam line at JET. In the NEC BPM, a single grounded wire formed into a 45 deg. segment of a helix is rotated by a motor about the axis of the helix. During each full revolution, the wire sweeps twice across the beam to give X and Y profiles. In this paper, we will describe the properties of the JET Li beam as measured with the BPM and demonstrate that it facilitates rapid optimization of the gun performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detecting missing struts in metallic micro-lattices using high speed melt pool thermal monitoring

Metal lattices are an important class of cellular materials that offer great advantages by providing high-strength and lightweight structures as compared to bulk materials. Progress in additive manufacturing techniques has led to increased complexity in design and shape of produced objects and is greatly beneficial for the development of metallic lattice structures. However additive manufacturing of lattices suffers from unpredictable defect creation that can compromise its mechanical integrity. Although post-build inspection techniques can provide quality assurance of the process, accurate assessment can be technically challenging, time consuming and costly. In this work, we investigate the use of high-speed measurements of thermal emission from the melt pool to identify defective individual struts formed with a missing bottom half in an otherwise fully built lattice structure produced with laser powder bed fusion. Surprisingly, results indicate lower photodiode signal, suggesting colder melt pool surface temperature, when printing struts with missing bottom half as compared to nominal struts. Additional thermographic imaging and multi-physics simulations reveal that the low photodiode signal is accompanied by presence of hot spatters carrying heat away from detection and continuous avalanche of powder on the melt pool. Based on these observations, a method was developed to identify defective individual struts with missing bottom half in full built lattices. This prediction approach provides valuable insights about part quality which are important for process qualification and illustrates the utility of melt pool thermal emission monitoring for identifying specific defects introduced by laser powder bed fusion.

36 MATERIALS SCIENCE↗

Calibrating IR Cameras for In-Situ Temperature Measurement During the Electron Beam Melting Process using Inconel 718 and Ti-Al6-V4

The Department of Energy s (DOE) Manufacturing Demonstration Facility (MDF) at Oak Ridge National Laboratory (ORNL) provides world-leading capabilities in advanced manufacturing (AM) facilities which leverage previous, on-going government investments in materials science research and characterization. MDF contains systems for fabricating components with complex geometries using AM techniques (i.e. 3D-Printing). Various metal alloy printers, for example, use electron beam melting (EBM) systems for creating these components which are otherwise extremely difficult- if not impossible- to machine. ORNL has partnered with manufacturers on improving the final part quality of components and developing new materials for further advancing these devices. One method being used to study (AM) processes in more depth relies on the advanced imaging capabilities at ORNL. High performance mid-wave infrared (IR) cameras are used for in-situ process monitoring and temperature measurements. However, standard factory calibrations are insufficient due to very low transmissions of the leaded glass window required for X-ray absorption. Two techniques for temperature calibrations will be presented and compared. In-situ measurement of emittance will also be discussed. Ample information can be learned from in-situ IR process monitoring of the EBM process. Ultimately, these imaging systems have the potential for routine use for online quality assurance and feedback control.

Electron-Beam Melting↗

Joint physics-based and data-driven time-lapse seismic inversion: Mitigating data scarcity

In carbon capture and sequestration (CCS), developing rapid and effective imaging techniques is crucial for real-time monitoring of the spatial and temporal dynamics of CO 2 propagation during/after injection. With continuing improvements in computational power and data storage, data-driven techniques based on machine learning (ML) have been effectively applied to seismic inverse problems. In particular, ML helps alleviate the ill-posedness and high computational cost of full-waveform inversion (FWI). However, such data-driven inversion techniques require massive high-quality training data sets to ensure prediction accuracy, which hinders their application to time-lapse monitoring of CO 2 sequestration. We propose an efficient “hybrid” time-lapse workflow that combines physics-based FWI and data-driven ML inversion. The scarcity of the available training data is addressed by developing a new data-generation technique with physics constraints. The method is vali dated on a synthetic CO 2 -sequestration model based on the Kimberlina storage reservoir in California. The proposed approach is shown to synthesize a large volume of high-quality, physically realistic training data, which is critically important in accurately characterizing the CO 2 movement in the reservoir. In conclusion, the developed hybrid methodology can also simultaneously predict the variations in velocity and saturation and achieve high spatial resolution in the presence of realistic noise in the data.

58 GEOSCIENCES↗

Bay Breeze Influence on Surface Ozone at Edgewood, MD During July 2011

Surface ozone (O3) was analyzed to investigate the role of the bay breeze on air quality at two locations in Edgewood, Maryland (lat: 39.4deg, lon: −76.3deg) for the month of July 2011. Measurements were taken as part of the first year of NASA's "Deriving Information on Surface Conditions from Column and Vertically Resolved Observations Relevant to Air Quality" (DISCOVER-AQ) Earth Venture campaign and as part of NASA's Geostationary for Coastal and Air Pollution Events Chesapeake Bay Oceanographic campaign with DISCOVER-AQ (Geo-CAPE CBODAQ). Geo-CAPE CBODAQ complements DISCOVER-AQ by providing ship-based observations over the Chesapeake Bay. A major goal of DISCOVER-AQ is determining the relative roles of sources, photochemistry and local meteorology during air quality events in the Mid-Atlantic region of the U.S. Surface characteristics, transport and vertical structures of O3 during bay breezes were identified using in-situ surface, balloon and aircraft data, along with remote sensing equipment. Localized late day peaks in O3 were observed during bay breeze days, maximizing an average of 3 h later compared to days without bay breezes. Of the 10 days of July 2011 that violated the U.S. Environmental Protection Agency (EPA) 8 h O3 standard of 75 parts per billion by volume (ppbv) at Edgewood, eight exhibited evidence of a bay breeze circulation. The results indicate that while bay breezes and the processes associated with them are not necessary to cause exceedances in this area, bay breezes exacerbate poor air quality that sustains into the late evening hours at Edgewood. The vertical and horizontal distributions of O3 from the coastal Edgewood area to the bay also show large gradients that are often determined by boundary layer stability. Thus, developing air quality models that can sufficiently resolve these dynamics and associated chemistry, along with more consistent monitoring of O3 and meteorology on and along the complex coastline of Chesapeake Bay must be a high priority.

bay breeze↗

MO-F-CAMPUS-J-01: A Novel and Efficient Daily QA Program for Both Modern Linear Accelerator and Optical Surface Motion Systems

Purpose: The camera-based optical surface monitoring system(OSMS) is a standard motion-tracking system for TrueBeam™ machine. Daily quality assurance(DQA) procedures for the TrueBeam and OSMS systems currently require multiple phantoms and test sequences. Machine Performance Check(MPC) uses the IsoCal™ phantom to test geometric and dosimetric aspects, and has been validated for routine TrueBeam DQA. This work examines the novel use of MPC to simultaneously conduct DQA of OSMS,utilizing one phantom and test sequence for QA of both the TrueBeam and OSMS systems. Methods: TrueBeam with 6 degree-of-freedom(6DOF) couch, MPC and OSMS were installed. The therapists routinely use MPC with the IsoCal phantom to verify geometric and dosimetric parameters with an automated sequence of varying gantry and collimator angles, MLC positions, and couch translations and rotations as the DQA for TrueBeam. A surface outline of the IsoCal phantom, generated from a CT dataset, was imported to OSMS and used to monitor the position of the phantom at isocenter and to track its movement up to 5cm/10°(yaw) and rotation in pitch and roll up to 3° in real time during the automated MPC sequence. Motion of the phantom throughout the MPC routine was compared to the couch position shown by the digital readout. Results: The coincidence of isocenter, as determined by OSMS, and TrueBeam radiation isocenter was within ±0.8mm/±0.8° in three axes. Between OSMS and TrueBeam 6DOF couch, the mean couch relative shifts/angles were within ±0.7mm/±0.8° for each axis. Reported pitch and roll values were within ±0.4mm/±0.4°. The total measurement time for each DQA session took approximately 5 minutes. Conclusion: Use of the IsoCal phantom and MPC for simultaneous DQA of TrueBeam and OSMS increases QA efficiency and reduces complexity. OSMS isocenter position and motion-tracking capability in 6DOF were verified in real-time and were found to be within 1mm of the expected value.

60 APPLIED LIFE SCIENCES↗

Resilient Monitoring Systems: Architecture, Design, and Application to Boiler/Turbine Plant

Resilient monitoring systems, considered in this paper, are sensor networks that degrade gracefully under malicious attacks on their sensors, causing them to project misleading information. The goal of this work is to design, analyze, and evaluate the performance of a resilient monitoring system intended to monitor plant conditions (normal or anomalous). The architecture developed consists of four layers: data quality assessment, process variable assessment, plant condition assessment, and sensor network adaptation. Each of these layers is analyzed by either analytical or numerical tools. The performance of the overall system is evaluated using a simplified boiler/turbine plant. The measure of resiliency is quantified using Kullback-Leibler divergence, and is shown to be sufficiently high in all scenarios considered.

97 MATHEMATICS AND COMPUTING↗

Tracking Smoke from a Prescribed Fire and its Impacts on Local Air Quality using Temporally Resolved GOES-16 ABI Aerosol Optical Depth (AOD)

Aerosol optical depth (AOD) retrieved from the GOES-16 Advanced Baseline Imager (ABI) was used to track a smoke plume from a prescribed fire in northeastern Virginia on 8 March 2020. Weather and atmospheric conditions created a favorable environment to transport the plume through the Washington, D.C., and Baltimore, Maryland, metro areas in the afternoon and concentrate smoke near the surface, degrading air quality for several hours. ABI AOD with 5-min temporal resolution and 2-km spatial resolution definitively identified the timing and geographic extent of the plume during daylight hours. Comparison to AERONET AOD indicates that ABI AOD captured the relative change in AOD due to passage of the smoke, with a mean absolute error of 0.047. Ground-based measurements of fine particulate matter (PM2.5) confirm deteriorations in air quality coincident with the progression of the smoke. Ceilometer aerosol backscatter profiles verify plume transport timing and indicate that smoke aerosols were well mixed in a shallow boundary layer. This event illustrates the advantages of using multiple datasets to analyze the impacts of aerosols on ambient air quality. Given the quickly evolving nature of the event over several hours, ABI AOD provided information for the public and decision-makers that was not available from any other source, including polar-orbiting satellite sensors. This study suggests that PM2.5 concentrations estimated from ABI AOD can be used to fill in the gaps in nationwide regulatory PM2.5 monitor networks and may be a valuable addition to EPA’s PM2.5 NowCast of current air quality conditions.

satellite observations↗

Elements of an environmental decision support system for seasonal wetland salt management in a river basin subjected to water quality regulation

Seasonally managed wetlands in the Grasslands Basin on the west-side of California's San Joaquin Valley provide food and shelter for migratory wildfowl during winter months and sport for waterfowl hunters during the annual duck season. Surface water supply to these wetlands contain salt which, when drained to the San Joaquin River during the annual drawdown period, can negatively impact water quality and cause concern to downstream agricultural riparian water diverters. Recent environmental regulation, limiting discharges salinity to the San Joaquin River and primarily targeting agricultural non-point sources, now also targets return flows from seasonally managed wetlands. Real-time water quality management has been advocated as a means of continuously matching salt loads discharged from agricultural, wetland and municipal operations to the assimilative capacity of the San Joaquin River. Past attempts to build environmental monitoring and decision support systems (EDSS's) to implement this concept have enjoyed limited success for reasons that are discussed in this paper. These reasons are discussed in the context of more general challenges facing the successful implementation of a comprehensive environmental monitoring, modelling and decision support system for the San Joaquin River Basin.

54 ENVIRONMENTAL SCIENCES↗

Surface erythemal UV irradiance in the continental United States derived from ground-based and OMI observations: quality assessment, trend analysis and sampling issues

Surface full-sky erythemal dose rate (EDR) from the Ozone Monitoring Instrument (OMI) at both satellite overpass time and local noon time is evaluated against ground measurements at 31 sites from the US Department of Agriculture's (USDA) UV-B Monitoring and Research Program (UVMRP) over the period of 2005–2017. We find that both OMI overpass and solar noon time EDR are highly correlated with the measured counterparts (with a linear correlation coefficient of 0.90 and 0.88, respectively). Although the comparison statistics are improved with a longer time window (0.5–1.0 h) for pairing surface and OMI measurements, both OMI overpass and local noon time EDRs have 7 % overestimation that is larger than 6 % uncertainty in the ground measurements and show different levels of dependence on solar zenith angle (SZA) and to lesser extent on cloud optical depth. The ratio of EDR between local noon and OMI overpass time is often (95 % in frequency) larger than 1 with a mean of 1.18 in the OMI product; in contrast, the same ratio from surface observation is normally distributed with 22 % of the times less than 1 and a mean of 1.38. This contrast in part reflects the deficiency in the OMI surface UV algorithm that assumes constant atmospheric conditions between overpass and noon time. The probability density functions (PDFs) for both OMI and ground measurements of noontime EDR are in statistically significant agreement, showing dual peaks at ∼20 and ∼200 mW/sq. m, respectively; the latter is lower than 220 mW/ sq. m, the value at which the PDF of daily EDR from ground measurements peaks, and this difference indicates that the largest EDR value for a given day may not often occur at local noon. Lastly, statistically significant positive trends of EDR are found in the northeastern US in OMI data, but opposite trends are found within ground-based data (regardless of sampling for either noontime or daily averages). While positive trends are consistently found between OMI and surface data for EDR over the southern Great Plains (Texas and Oklahoma), their values are within the uncertainty of ground measurements. Overall, no scientifically sound trends can be found among OMI data for aerosol total and absorbing optical depth, cloud optical depth and total ozone to explain coherently the surface UV trends revealed either by OMI or ground-based estimates; these data also cannot reconcile trend differences between the two estimates (of EDR from OMI and surface observations). Future geostationary satellites with better spatiotemporal resolution data should help overcome spatiotemporal sampling issues inherent in OMI data products and therefore improve the estimates of surface UV flux and EDR from space.

Ozone Monitoring Instrument (OMI)↗

Resilient Plant Monitoring System: Design, Analysis, and Performance Evaluation

Resilient monitoring systems are sensor networks that degrade gracefully under malicious attacks on their sensors, causing them to project misleading information. The goal of this paper is to design, analyze, and evaluate the performance of a resilient monitoring system intended to monitor plant conditions (normal or anomalous). The architecture developed consists of four layers: data quality assessment, process variable assessment, plant condition assessment, and sensor network adaptation. Each of these layers is analyzed by either analytical or numerical tools, and the performance of the overall system is evaluated using simulations. The measure of resiliency of the resulting system is evaluated using Kullback Leibler divergence, and is shown to be sufficiently high in all scenarios considered.

97 MATHEMATICS AND COMPUTING↗

Workshop on Satellite and In situ Observations for Climate Prediction

Participants in this workshop, which convened in Venice, Italy, 6-8 May 1993, met to consider the current state of climate monitoring programs and instrumentation for the purpose of climatological prediction on short-term (seasonal to interannual) timescales. Data quality and coverage requirements for definition of oceanographic heat and momentum fluxes, scales of inter- and intra-annual variability, and land-ocean-atmosphere exchange processes were examined. Advantages and disadvantages of earth-based and spaceborne monitoring systems were considered, as were the structures for future monitoring networks, research programs, and modeling studies.

Acker, James G.↗