Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantitative”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Quantitative microinjection using fluorescence calibration of streaming microdroplets on a superhydrophobic surface

Highlights: • Superhydrophobic surfaces prevent droplet surface adhesion and deformation. • Wide tipped micropipettes create a stream of microdroplets. • Streaming creates a large number of varying sized droplets quickly and easily. • Fluorescence-volume calibration curves can be created with tracer microdroplets. • Calibrated fluorescent tracers allow for quantifiable, cellular microinjection. A simple and reproducible procedure was developed to measure the volume of liquid microinjected into cells. A calibration curve of droplet fluorescence intensity versus volume was constructed by injecting a fluorescent dextran solution through a 125–150 µm diameter micropipette into an oil-filled culture dish to create a spray of varied-sized droplets. The droplets retained a spherical shape because they were in an oil medium and they settled onto a glass surface coated with a superhydrophobic surface. Fluorescent micrographs of the droplets were obtained and analyzed with Image-J software to quantify the fluorescence intensity and radius of each spherical droplet to produce the calibration curve. Subsequently, Dut-145 human prostate carcinoma cells were microinjected with the same fluorescent dextran solution and fluorescent micrographs of the cells were obtained using the identical exposure conditions used to photograph the droplets. The measured fluorescence intensity of the microinjected cells was entered into the formula for the regression line that was fit to the calibration curve allowing determination of the volume of solution injected into each cell. Thus, a mixture consisting of known concentrations of a test material of test material (macromolecules, drugs, etc.) and a fluorescent dextran, volumetric, tracer can be used to quantify the relationship between the amount of a microinjected material and subsequent effects on cells.

60 APPLIED LIFE SCIENCES↗

A quantitative assessment of the model form error of friction models across different interface representations for jointed structures

Hysteretic models are widely used to model frictional interactions in joints to recreate experimental behavior. However, it is unclear which models are best suited for fitting or predicting the responses of structures. Here, the present study evaluates 26 friction model/interface representation combinations to quantify the model form error. A Quasi-Static Modal Analysis approach (termed Rayleigh Quotient Nonlinear Modal Analysis) is adopted to calculate the nonlinear system response, and a Multi-Objective Optimization is solved to fit experimental data of the first mode of the Brake-Reuß Beam. Optimized parameters from the first mode are applied to the second and third bending modes to quantify the predictive ability of the models. Formulations for both tracing full hysteresis loops and recreating hysteresis loops from a single loading curve (Masing assumptions) are considered. Smoothly varying models applied to a five patch representation showed the highest flexibility (for fitting mode 1) and good predictive potential (for modes 2 and 3). For a second formulation, which uses 152 frictional elements to represent the interface, the physically motivated spring in series with a Coulomb slip model (elastic dry friction) has high error for fitting mode 1 and performs near the middle for predicting higher modes. For both interface representation, the best fit models are not the most physical, but rather the ones with the most parameters (as expected); however, the more physical models perform somewhat better for predicting the higher modes.

42 ENGINEERING↗

Quantitative Assessment and Measurement of X-ray Detector Performance and Solid Angle in the Analytical Electron Microscope

A wide range of X-ray detectors and geometries are available today on transmission/scanning transmission analytical electron microscopes. While there have been numerous reports of their individual performance, no single experimentally reproducible metric has been proposed as a basis of comparison between the systems. In this paper, we detail modeling, experimental procedures, measurements, and specimens which can be used to provide a manufacturer-independent assessment of the performance of an analytical system. Using these protocols, the geometrical collection efficiency, system peaks, and minimum detection limits can be independently assessed and can be used to determine the best conditions to conduct modern hyperspectral and/or spectrally resolved tomographic analyses for an individual instrument. Here, a simple analytical formula and specimen is presented which after suitable system calibrations can be used to experimentally determine the X-ray detector solid angle.

47 OTHER INSTRUMENTATION↗

Quantitative Confocal Raman Microscopy Study of Ion-Interaction Retention at Reversed-Phase Chromatographic Interfaces

Ion-interaction chromatography utilizes the addition of amphiphilic (surfactant) molecules to the mobile phase solution in order to bring about the retention and separation of hydrophilic ionic analytes on reversed-phase liquid chromatographic stationary phases. The mechanism by which retention and separation in ion-interaction chromatography is accomplished remains unclear, although two primary mechanisms of this phenomenon have been proposed: pre-adsorption of the hydrophobic counter ions to the hydrophobic stationary phase followed by interaction with the ionic analyte, or ion pairing in solution with subsequent sorption of the paired species to the hydrophobic surface. There is evidence that both mechanisms contribute to ionic retention and separations. In this work, ion interactions at a C18 stationary phase interface are investigated by confocal Raman microscopy of individual stationary-phase particles, which is capable of quantifying surface concentrations of surfactants and model solutes. Raman spectra taken within the interior of the particle indicate that pre-adsorption of the hydrophobic surfactant cetylpyridinium to the stationary phase interface is sensitive to ionic strength and concentration of organic modifier in the mobile phase. Furthermore, it was also determined that the presence of low concentrations of a model, ionic solute, nitrobenzenesulfonate, leads to greater adsorption of cetylpyridinium ion at the hydrophobic interface. As the concentration of nitrobenzenesulfonate is increased, the 1:1 increase in the cetylpyridinium-ion interfacial concentration provides evidence of ion pairs forming at the stationary phase surface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Raman Spectroscopy Coupled with Chemometric Analysis for Speciation and Quantitative Analysis of Aqueous Phosphoric Acid Systems

Complex chemical systems that exhibit varied and matrix-dependent speciation are notoriously difficult to monitor and characterize on-line and in real-time. Optical spectroscopy is an ideal tool for in situ characterization of chemical species that can enable quantification as well as species identification. Chemometric modeling, a multivariate method, has been successfully paired with optical spectroscopy to enable measurement of analyte concentrations even in complex solutions where univariate methods such as Beer’s law analysis fail. Here, Raman spectroscopy is used to quantify the concentration of phosphoric acid and its three deprotonated forms during a titration. In this system, univariate approaches would be difficult to apply due to multiple species being present simultaneously within the solution as pH is varied. Locally Weighted Regression (LWR) modeling was used to determine phosphate concentration from spectral signature. LWR results, in tandem with Multivariate Curve Resolution modeling, provide direct measurement of the concentration of each phosphate species using only the Raman signal. Furthermore, results are presented within the context of fundamental solution chemistry, including Pitzer equations to compensate for activity coefficients and non-idealities associated with high ionic strength systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transparent Carbon Ultramicroelectrode Arrays: Figures of Merit for Quantitative Spectroelectrochemistry for Biogenic Analysis of Reactive Oxygen Species

Opaque and transparent carbon ultramicro- to nanoelectrode arrays were made using a previously reported facile versatile fabrication method (Duay et al. Anal. Chem. 2014, 86, 11528). Initially, opaque carbon ultramicroelectrode arrays (CUAs) were characterized for their analytical response to hydrogen peroxide (H 2 O 2 ) oxidation using cyclic voltammetry. The alumina blocking layer was found to contribute to the noise and thus had undesirable effects on the array’s limit of detection (LOD) for H 2 O 2 at fast scan rates. Nonetheless, at slower scan rates (ν ≤ 250 mV s –1 ), the LODs for H 2 O 2 for both opaque (O-CUAs) and transparent arrays (T-CUAs) were discovered to be lower than previously reported levels for array-based UMEs. LODs as low as 35 nM H 2 O 2 are obtained for T-CUA at a 2.5 mV s –1 scan rate. Furthermore, the transparent arrays were analyzed for their spectroelectrochemical response during the oxidation/reduction of ferrocenemethanol. Results showed very good correlation between the optical and electrochemical response for ferrocenemethanol at a UV wavelength of 254 nm. Thus, these electrodes allow for the in situ mechanistic and kinetic characterization of heterogeneous electrochemical and intermediate homogeneous chemical reactions with high electroanalytical sensitivity, low detection limits, and wide dynamic range.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Colorimetric-Luminance Readout for Quantitative Analysis of Fluorescence Signals with a Smartphone CMOS Sensor

Smartphones have shown promise as an enabling technology for portable and distributed point-of-care diagnostic tests. The CMOS camera sensor can be used for detecting optical signals, including fluorescence for applications such as isothermal nucleic acid amplification tests. However, such analysis is typically limited mostly to end point detection of single targets. In this paper, we present a smartphone-based image analysis pipeline that utilizes the CIE xyY (chromaticity-luminance) color space to measure the luminance (in lieu of RGB intensities) of fluorescent signals arising from nucleic acid amplification targets, with a discrimination sensitivity (ratio between the positive to negative signals), which is an order of magnitude more than traditional RGB intensity based analysis. Furthermore, the chromaticity part of the analysis enables reliable multiplexed detection of different targets labeled with spectrally separated fluorophores. We apply this chromaticity-luminance formulation to simultaneously detect Zika and chikungunya viral RNA via end point RT-LAMP (Reverse transcription Loop-Mediated isothermal amplification). We also show real time LAMP detection of Neisseria gonorrhoeae samples down to a copy number of 3.5 copies per 10 μL of reaction volume in our smartphone-operated portable LAMP box. Finally, our chromaticity-luminance analysis is readily adaptable to other types of multiplexed fluorescence measurements using a smartphone camera.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗