Search NASA⌕ Search

SEARCH · Search NASA

Results for “read performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Large format imaging arrays for the Atacama Cosmology Telescope

We describe progress in the fabrication, characterization, and production of detector arrays for the Atacama Cosmology Telescope (ACT). The completed ACT instrument is specified to image simultaneously at 145, 225, and 265 GHz using three 32x32 filled arrays of superconducting transition edge sensors (TES) read out with time-division-multiplexed SQUID amplifiers. We present details of the pixel design and testing including the optimization of the electrical parameters for multiplexed readout. Using geometric noise suppression and careful tuning of operation temperature and device bias resistance, the excess noise in the TES devices is balanced with detector speed for interfacing with the ACT optics. The design also accounts for practical tolerances such as transition temperature gradients and scatter that occur in the production of multiple wafers to populate fully the kilopixel cameras. We have developed an implanted absorber layer compatible with our silicon-on-insulator process that allows for tunable optical resistance with requisite on-wafer uniformity and wafer-to-wafer reproducibility. Arrays of 32 elements have been tested in the laboratory environment including electrical, optical, and multiplexed performance. Given this pixel design, optical tests and modeling are used to predict the performance of the filled array under anticipated viewing conditions. Integration of the filled array of pixels with a tuned backshort and dielectric plate in front of the array maximize absorption and the focal plane and suppress reflections. A mechanical design for the build of the full structure is completed and we report on progress toward the construction of a prototype array for first light on the ACT.

Chervenak, J. A.↗

A Tool for the Automated Collection of Space Utilization Data: Three Dimensional Space Utilization Monitor

Space Human Factors and Habitability (SHFH) Element within the Human Research Program (HRP) and the Behavioral Health and Performance (BHP) Element are conducting research regarding Net Habitable Volume (NHV), the internal volume within a spacecraft or habitat that is available to crew for required activities, as well as layout and accommodations within the volume. NASA needs methods to unobtrusively collect NHV data without impacting crew time. Data required includes metrics such as location and orientation of crew, volume used to complete tasks, internal translation paths, flow of work, and task completion times. In less constrained environments methods exist yet many are obtrusive and require significant post-processing. Examplesused in terrestrial settings include infrared (IR) retro-reflective marker based motion capture, GPS sensor tracking, inertial tracking, and multi-camera methods Due to constraints of space operations many such methods are infeasible. Inertial tracking systems typically rely upon a gravity vector to normalize sensor readings,and traditional IR systems are large and require extensive calibration. However, multiple technologies have not been applied to space operations for these purposes. Two of these include: 3D Radio Frequency Identification Real-Time Localization Systems (3D RFID-RTLS) Depth imaging systems which allow for 3D motion capture and volumetric scanning (such as those using IR-depth cameras like the Microsoft Kinect or Light Detection and Ranging / Light-Radar systems, referred to as LIDAR)

Vos, Gordon A.↗

Interface design of VSOP'94 computer code for safety analysis

Today, most software applications, also in the nuclear field, come with a graphical user interface. VSOP'94 (Very Superior Old Program), was designed to simplify the process of performing reactor simulation. VSOP is a integrated code system to simulate the life history of a nuclear reactor that is devoted in education and research. One advantage of VSOP program is its ability to calculate the neutron spectrum estimation, fuel cycle, 2-D diffusion, resonance integral, estimation of reactors fuel costs, and integrated thermal hydraulics. VSOP also can be used to comparative studies and simulation of reactor safety. However, existing VSOP is a conventional program, which was developed using Fortran 65 and have several problems in using it, for example, it is only operated on Dec Alpha mainframe platforms and provide text-based output, difficult to use, especially in data preparation and interpretation of results. We develop a GUI-VSOP, which is an interface program to facilitate the preparation of data, run the VSOP code and read the results in a more user friendly way and useable on the Personal 'Computer (PC). Modifications include the development of interfaces on preprocessing, processing and postprocessing. GUI-based interface for preprocessing aims to provide a convenience way in preparing data. Processing interface is intended to provide convenience in configuring input files and libraries and do compiling VSOP code. Postprocessing interface designed to visualized the VSOP output in table and graphic forms. GUI-VSOP expected to be useful to simplify and speed up the process and analysis of safety aspects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Unexpected origin of the quantum efficiency reduction in long-wavelength (In,Ga)⁢N light-emitting diodes

Differential carrier lifetime (DCL) measurements were performed on c-plane In 𝑥 ⁢Ga 1−𝑥⁢ N/Ga⁢N single-quantum-well (QW) light-emitting diodes (LEDs) with varying indium-content QWs (x = 13.5%, 16%, 22%), emitting with violet, blue, and green wavelengths. The recombination lifetimes of LEDs were found to increase with increasing indium composition, resulting in increased carrier densities n measured by DCL. Extraction of the A coefficients, which are assumed to not vary with n, and of the effective B(n) and C(n) coefficients of the ABC model of the internal quantum efficiency (IQE) of QWs showed no significant changes in the A coefficient with increasing indium content [In] in the In 𝑥 ⁢Ga 1−𝑥 ⁢N QW, and a reduction in the B(n) and C(n) coefficients with increasing [In]. When looking at the Shockley-Read-Hall (SRH) recombination rate An, the radiative recombination rate B(n)𝑛 2 , and the Auger-Meitner (AM) recombination rate C(n)𝑛 3 , we observed that at any given n, the SRH rate is the same for the three [In] measured, while the radiative rate decreases (by up to approximately 9 times) and the AM rate decreases (by up to approximately 7 times) with increasing indium content. This shows that the larger reduction in radiative recombination rates relative to nonradiative recombination rates with increasing [In] is the largest contributor to the decreased quantum efficiencies of LEDs (the “green gap”) at any given n. While some of the reduction in the effective recombination coefficients B(n) and C(n) can be explained by the reduced wave-function overlaps of the QW with increasing indium content, the larger reduction of B(n) relative to C(n) motivates further study of the intrinsic recombination coefficients 𝐵 0 and 𝐶 0 of bulk In 𝑥 ⁢Ga 1−𝑥 ⁢N alloys and how they are related to the effective recombination coefficients B(n) and C(n) in QWs. The relative contributions of nonradiative recombination are enhanced at any given current density due to the sublinear relationship between the carrier density n and the current density. Thus, the solution to the green gap, up to any intrinsic limitations set by the indium content of the QW, from an IQE perspective, requires the design of long-wavelength (In,Ga)⁢N LEDs with improved wave-function overlaps that can operate with a lower carrier density at any given current density.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Grid Generation Techniques Utilizing the Volume Grid Manipulator

This paper presents grid generation techniques available in the Volume Grid Manipulation (VGM) code. The VGM code is designed to manipulate existing line, surface and volume grids to improve the quality of the data. It embodies an easy to read rich language of commands that enables such alterations as topology changes, grid adaption and smoothing. Additionally, the VGM code can be used to construct simplified straight lines, splines, and conic sections which are common curves used in the generation and manipulation of points, lines, surfaces and volumes (i.e., grid data). These simple geometric curves are essential in the construction of domain discretizations for computational fluid dynamic simulations. By comparison to previously established methods of generating these curves interactively, the VGM code provides control of slope continuity and grid point-to-point stretchings as well as quick changes in the controlling parameters. The VGM code offers the capability to couple the generation of these geometries with an extensive manipulation methodology in a scripting language. The scripting language allows parametric studies of a vehicle geometry to be efficiently performed to evaluate favorable trends in the design process. As examples of the powerful capabilities of the VGM code, a wake flow field domain will be appended to an existing X33 Venturestar volume grid; negative volumes resulting from grid expansions to enable flow field capture on a simple geometry, will be corrected; and geometrical changes to a vehicle component of the X33 Venturestar will be shown.

Alter, Stephen J.↗

A Reactive Inkjet Printing Process for Fabricating Biodegradable Conductive Zinc Structures

A novel reactive inkjet printing (RIJ) process for fabricating environmentally benign, conductive zinc structures on biodegradable substrates is reported. A precursor consisting of oxidized zinc microparticles is formulated into a viscous ink for high‐resolution, high‐repeatability screen printing. A single RIJ process is performed to selectively dispense an acid‐based oxide etching agent onto the screen‐printed zinc ink to significantly improve its electrical conductivity, up to 4 × 10 4 S m −1 . The RIJ process enables precise control of the amount of deposited etching agent, allowing control of conductivity and avoiding damage caused by excessive acid exposure. The RIJ process deposits the etching agent selectively on the screen‐printed, water‐soluble zinc patterns, thus preserving the print fidelity by avoiding ink smearing that can occur when using a blanket treatment such as submersion. A printed biodegradable antenna with a minimum feature size of 500 μm for use with a batteryless radio frequency identification (RFID) chip is fabricated as demonstration. Due to the higher ink conductivity and improved pattern fidelity, the antenna fabricated by the RIJ process shows a ≈2.2× increase in reading distance compared with a similar antenna that is screen printed and activated using a drop‐casting process.

Sui, Yongkun↗

Calibration of measurement sensitivities of multiple micro-cantilever dynamic modes in atomic force microscopy using a contact detection method

An accurate experimental method is proposed for on-spot calibration of the measurement sensitivities of multiple micro-cantilever dynamic modes in atomic force microscopy. One of the key techniques devised for this method is a reliable contact detection mechanism that detects the tip-surface contact instantly. At the contact instant, the oscillation amplitude of the tip deflection, converted to that of the deflection signal in laser reading through the measurement sensitivity, exactly equals to the distance between the sample surface and the cantilever base position. Therefore, the proposed method utilizes the recorded oscillation amplitude of the deflection signal and the base position of the cantilever at the contact instant for the measurement sensitivity calibration. Experimental apparatus along with various signal processing and control modules was realized to enable automatic and rapid acquisition of multiple sets of data, with which the calibration of a single dynamic mode could be completed in less than 1 s to suppress the effect of thermal drift and measurement noise. Calibration of the measurement sensitivities of the first and second dynamic modes of three micro-cantilevers having distinct geometries was successfully demonstrated. The dependence of the measurement sensitivity on laser spot location was also experimentally investigated. Finally, an experiment was performed to validate the calibrated measurement sensitivity of the second dynamic mode of a micro-cantilever.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CodeScribe Agent

SF-26-086 CodeScribe introduces a structured, multi-stage pipeline that combines deterministic program analysis with LLM-powered translation to enable incremental, testable Fortran-to-C++ migration. First, `code-scribe index` traverses the project directory tree and produces `scribe.yaml` metadata files recording all modules, subroutines, and functions at each level, giving the LLM accurate structural context instead of a hallucinated codebase model. Second, `code-scribe draft` performs the deterministic portion of translation — converting Fortran types to C++ equivalents, replacing `use` statements with `#include` and `using namespace` directives, and detecting constructs requiring special handling — while embedding`scribe-prompt` annotations that guide the LLM through non-trivial cases such as statement-function-to-lambda conversions and `extern "C"` wrapper generation. Third, `code-scribe translate` applies project-specific TOML-based few-shot prompt templates and submits the composed prompt to a pluggable LLM backend (OpenAI, Anthropic, Argonne ARGO, any OpenAI-compatible endpoint, or local Hugging Face checkpoints), producing a C++ source file, a header, and a Fortran-C++ interface file for each translated routine so the codebase compiles and runs correctly throughout the migration. Beyond translation, CodeScribe includes a tool-using coding agent (`code-scribe agent`) with read, bash, edit, and write capabilities, and a bounded loop mode (`code-scribe loop`) that runs repeated stateless agent sessions over a task file with restricted tool access — enabling sustained, auditable software development workflows for broader scientific computing tasks.

Dhruv, Akash [Argonne National Laboratory (ANL), A↗

Extension of Generalized Fluid System Simulation Program's Fluid Property Database

This internship focused on the development of additional capabilities for the General Fluid Systems Simulation Program (GFSSP). GFSSP is a thermo-fluid code used to evaluate system performance by a finite volume-based network analysis method. The program was developed primarily to analyze the complex internal flow of propulsion systems and is capable of solving many problems related to thermodynamics and fluid mechanics. GFSSP is integrated with thermodynamic programs that provide fluid properties for sub-cooled, superheated, and saturation states. For fluids that are not included in the thermodynamic property program, look-up property tables can be provided. The look-up property tables of the current release version can only handle sub-cooled and superheated states. The primary purpose of the internship was to extend the look-up tables to handle saturated states. This involves a) generation of a property table using REFPROP, a thermodynamic property program that is widely used, and b) modifications of the Fortran source code to read in an additional property table containing saturation data for both saturated liquid and saturated vapor states. Also, a method was implemented to calculate the thermodynamic properties of user-fluids within the saturation region, given values of pressure and enthalpy. These additions required new code to be written, and older code had to be adjusted to accommodate the new capabilities. Ultimately, the changes will lead to the incorporation of this new capability in future versions of GFSSP. This paper describes the development and validation of the new capability.

Patel, Kishan↗

Godiva-IV Dosimetry Exercise 2022 Preliminary Results

Integral Experiment Request (IER) 538 is part of a series of dose characterization and nuclear accident dosimetry (NAD) exercises performed under the Department of Energy (DOE) Nuclear Criticality Safety Program (NCSP). This is the second NAD exercise using the Godiva-IV critical assembly and the third NAD exercise overall. The participating laboratories provided their own dosimeters that were mounted on the Lawrence Livermore National Laboratory (LLNL) BOttle Manikin ABsorption (BOMAB) phantoms and aluminum plates. The BOMABs and plates were placed at two, three, and four meters away from the center of Godiva. Alongside the NADs, there was a LLNL Passive Neutron Spectrometer (PNS), Atomic Weapons Establishment (AWE) PNS, and Y-12 Sphere present to measure the neutron dose from Godiva. Two irradiations were conducted to test the NAD performance from each laboratory and assesses their performance to the DOE-STD-1098-2017 part 515 criteria. Neutron and gamma doses were measured prior to this exercise. This work presents a model for the neutron and gamma dose respectively to serve as the reference value. A code written in C/C++/ROOT was used to fit the measured neutron and gamma dose with the new models. It was assumed that the neutron and gamma doses are proportional to the change in temperature of Godiva after a burst irradiation. Uncertainties for the reference values were calculated using error propagation of the model’s parameters. Preliminary results (within twenty-four hours) and final results were compared for each laboratory. On average of all the participating laboratories, 32% of neutron doses and 78% of gamma doses were outside the DOE standards. One laboratory did not report their dose readings and were not included in this average. There is a bias for a lower neutron dose and a higher gamma dose based on the distribution of results. In comparison with the past Godiva-IV NAD exercise, there is an improvement in neutron dose readings by 20%.

BOttle Manikin ABsorption (BOMAB)↗

TuckerMPI: A Parallel C++/MPI Software Package for Large-scale Data Compression via the Tucker Tensor Decomposition

With this study, our goal is compression of massive-scale grid-structured data, such as the multi-terabyte output of a high-fidelity computational simulation. For such data sets, we have developed a new software package called TuckerMPI, a parallel C++/MPI software package for compressing distributed data. The approach is based on treating the data as a tensor, i.e., a multidimensional array, and computing its truncated Tucker decomposition, a higher-order analogue to the truncated singular value decomposition of a matrix. The result is a low-rank approximation of the original tensor-structured data. Compression efficiency is achieved by detecting latent global structure within the data, which we contrast to most compression methods that are focused on local structure. In this work, we describe TuckerMPI, our implementation of the truncated Tucker decomposition, including details of the data distribution and in-memory layouts, the parallel and serial implementations of the key kernels, and analysis of the storage, communication, and computational costs. We test the software on 4.5 and 6.7 terabyte data sets distributed across 100 s of nodes (1,000 s of MPI processes), achieving compression ratios between 100 and 200,000×, which equates to 99--99.999% compression (depending on the desired accuracy) in substantially less time than it would take to even read the same dataset from a parallel file system. Moreover, we show that our method also allows for reconstruction of partial or down-sampled data on a single node, without a parallel computer so long as the reconstructed portion is small enough to fit on a single machine, e.g., in the instance of reconstructing/visualizing a single down-sampled time step or computing summary statistics. The code is available at https://gitlab.com/tensors/TuckerMPI.

97 MATHEMATICS AND COMPUTING↗

Using the tabulated diffusion flamelet model ADF-PCM to simulate a lifted methane-air jet flame

Two formulations of a turbulent combustion model based on the approximated diffusion flame presumed conditional moment (ADF-PCM) approach [J.-B. Michel, O. Colin, D. Veynante, Combust. Flame 152 (2008) 80-99] are presented. The aim is to describe autoignition and combustion in nonpremixed and partially premixed turbulent flames, while accounting for complex chemistry effects at a low computational cost. The starting point is the computation of approximate diffusion flames by solving the flamelet equation for the progress variable only, reading all chemical terms such as reaction rates or mass fractions from an FPI-type look-up table built from autoigniting PSR calculations using complex chemistry. These flamelets are then used to generate a turbulent look-up table where mean values are estimated by integration over presumed probability density functions. Two different versions of ADF-PCM are presented, differing by the probability density functions used to describe the evolution of the stoichiometric scalar dissipation rate: a Dirac function centered on the mean value for the basic ADF-PCM formulation, and a lognormal function for the improved formulation referenced ADF-PCM{chi}. The turbulent look-up table is read in the CFD code in the same manner as for PCM models. The developed models have been implemented into the compressible RANS CFD code IFP-C3D and applied to the simulation of the Cabra et al. experiment of a lifted methane jet flame [R. Cabra, J. Chen, R. Dibble, A. Karpetis, R. Barlow, Combust. Flame 143 (2005) 491-506]. The ADF-PCM{chi} model accurately reproduces the experimental lift-off height, while it is underpredicted by the basic ADF-PCM model. The ADF-PCM{chi} model shows a very satisfactory reproduction of the experimental mean and fluctuating values of major species mass fractions and temperature, while ADF-PCM yields noticeable deviations. Finally, a comparison of the experimental conditional probability densities of the progress variable for a given mixture fraction with model predictions is performed, showing that ADF-PCM{chi} reproduces the experimentally observed bimodal shape and its dependency on the mixture fraction, whereas ADF-PCM cannot retrieve this shape. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Technical Evaluation of Radiation Dose Delivered in Prostate Cancer Patients as Measured by an Implantable MOSFET Dosimeter

Purpose: To perform a comparison of the daily measured dose at depth in tissue with the predicted dose values from treatment plans for 29 prostate cancer patients involved in a clinical trial. Methods and Materials: Patients from three clinical sites were implanted with one or two dosimeters in or near the prostatic capsule. The implantable device, known as the DVS, is based on a metal-oxide-semiconductor field effect transistor (MOSFET) detector. A portable telemetric readout system couples to the dosimeter antenna (visible on kilovoltage, computed tomography, and ultrasonography) for data transfer. The predicted dose values were determined by the location of the MOSFET on the treatment planning computed tomography scan. Serial computed tomography images were taken every 2 weeks to evaluate any migration of the device. The clinical protocol did not permit alteration of the treatment parameters using the dosimeter readings. For some patients, one of several image-guided radiotherapy (RT) modalities was used for target localization. Results: The evaluation of dose discrepancy showed that in many patients the standard deviation exceeded the previous values obtained for the dosimeter in a phantom. In some patients, the cumulative dose disagreed with the planned dose by {>=}5%. The data presented suggest that an implantable dosimeter can help identify dose discrepancies (random or systematic) for patients treated with external beam RT and could be used as a daily treatment verification tool for image-guided RT and adaptive RT. Conclusion: The results of our study have shown that knowledge of the dose delivered per fraction can potentially prevent over- or under-dosage to the treatment area and increase the accuracy of RT. The implantable dosimeter could also be used as a localizer for image-guided RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Implicit and Explicit Spacecraft Gyro Calibration

This paper presents a comparison between two approaches to sensor calibration. According to one approach, called explicit, an estimator compares the sensor readings to reference readings, and uses the difference between the two to estimate the calibration parameters. According to the other approach, called implicit, the sensor error is integrated to form a different entity, which is then compared with a reference quantity of this entity, and the calibration parameters are inferred from the difference. In particular this paper presents the comparison between these approaches when applied to in-flight spacecraft gyro calibration. Reference spacecraft rate is needed for gyro calibration when using the explicit approach; however, such reference rates are not readily available for in-flight calibration. Therefore the calibration parameter-estimator is expanded to include the estimation of that reference rate, which is based on attitude measurements in the form of attitude-quaternion. A comparison between the two approaches is made using simulated data. It is concluded that the performances of the two approaches are basically comparable. Sensitivity tests indicate that the explicit filter results are essentially insensitive to variations in given spacecraft dynamics model parameters.

Bar-Itzhack, Itzhack Y.↗

Nonideal Effects Limit the Efficiency Gain for Angle-Restricted Solar Cells

We report that performance of a conventional solar cell at 1 sun is limited to ~31%, defined by the Shockley–Queisser (SQ) limit. The thermodynamic limit can be improved to ~41% by reducing the angle mismatch between incident light and emitted rays. This can be achieved either by increasing the range of incident angles (as in a concentrator cell; CPV) or by reducing the emission angle from the device (angle-restricted photovoltaics; APVs). The equivalence is exact in the radiative limit. However, the gains of angle-restricted cells may erode rapidly once nonradiative recombination and other optical losses are accounted for, suggesting the need for quantitative/careful design. Here, we report a detailed self-consistent absorption-emission-transport study to 1) define the limiting efficiency of APV scheme and 2) explain the efficiency loss due to practical constraints, such as Shockley–Read–Hall (SRH) and Auger recombination, and mirror reflectivity. Our analysis reflects a growing consensus in the field that any imperfection of the mirror quickly diminishes the advantages of angle restriction. Finally, we conclude that a 50-nm angle-restricted cell with moderate material quality, but with nearly perfect mirror and Lambertian trapping, may be ~36–37% efficient.

14 SOLAR ENERGY↗

Loran-C approach guidance project current status

There are four areas of work in the Loran-C flight test project. Current results provide performance data on the effects of Signal Noise Ratio (SNR) on the dynamic performance of the receiver filters for Loran-C data, and data on Loran-C grid deformation at a microscale of 100 meters. The Loran-C receiver provides a line of position (LOP) Master and Slave transmitter at an angle 0 to magnetic north. No transformation to latitude-longitude reference frame is required since this is the major source of Loran-C navigation errors. A local coordinate frame is established centered at touchdown point on the runway with directions along and across the runway. A Loran-C data collection system was set up. The Loran-C data are sent directly to an Apple II computer with a 12 inch monitor. The effect of SNR on Loran-C precision is shown for two receiver filters of different frequency response. A set of ground level static readings of touchdown was taken around Hanscom Field and transferred to an accurate detailed layout drawing; this showed local distortions of the average touchdown values.

Elias, A. L.↗

Universal topological quantum computation with strongly correlated Majorana edge modes

Abstract Majorana-based quantum gates are not complete for performing universal topological quantum computation while Fibonacci-based gates are difficult to be realized electronically and hardly coincide with the conventional quantum circuit models. In reference Hu and Kane (2018 Phys. Rev. Lett. 120 066801), it has been shown that a strongly correlated Majorana edge mode in a chiral topological superconductor can be decomposed into a Fibonacci anyon τ and a thermal operator anyon ɛ in the tricritical Ising model. The deconfinement of τ and ɛ via the interaction between the fermion modes yields the anyon collisions and gives the braiding of either τ or ɛ . With these braidings, the complete members of a set of universal gates, the Pauli gates, the Hadamard gate and extra phase gates for one-qubit as well as controlled-NOT (CNOT) gate for two-qubits, are topologically assembled. Encoding quantum information and reading out the computation results can be carried out through electric signals. With the sparse-dense mixed encodings, we set up the quantum circuit where the CNOT gate turns out to be a probabilistic gate and design the corresponding devices with thin films of the chiral topological superconductor. As an example of the universal topological quantum computing, we show the application to Shor’s integer factorization algorithm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Patient radiation dose in prospectively gated axial CT coronary angiography and retrospectively gated helical technique with a 320-detector row CT scanner

Purpose: The aim of this study was to evaluate radiation dose to patients undergoing computed tomography coronary angiography (CTCA) for prospectively gated axial (PGA) technique and retrospectively gated helical (RGH) technique. Methods: Radiation doses were measured for a 320-detector row CT scanner (Toshiba Aquilion ONE) using small sized silicon-photodiode dosimeters, which were implanted at various tissue and organ positions within an anthropomorphic phantom for a standard Japanese adult male. Output signals from photodiode dosimeters were read out on a personal computer, from which organ and effective doses were computed according to guidelines published in the International Commission on Radiological Protection Publication 103. Results: Organs that received high doses were breast, followed by lung, esophagus, and liver. Breast doses obtained with PGA technique and a phase window width of 16% at a simulated heart rate of 60 beats per minute were 13 mGy compared to 53 mGy with RGH technique using electrocardiographically dependent dose modulation at the same phase window width as that in PGA technique. Effective doses obtained in this case were 4.7 and 20 mSv for the PGA and RGH techniques, respectively. Conversion factors of dose length product to the effective dose in PGA and RGH were 0.022 and 0.025 mSv mGy{sup -1} cm{sup -1} with a scan length of 140 mm. Conclusions: CTCA performed with PGA technique provided a substantial effective dose reduction, i.e., 70%-76%, compared to RGH technique using the dose modulation at the same phase windows as those in PGA technique. Though radiation doses in CTCA with RGH technique were the same level as, or some higher than, those in conventional coronary angiography (CCA), the use of PGA technique reduced organ and effective doses to levels less than CCA except for breast dose.

60 APPLIED LIFE SCIENCES↗