Convective Heat Transfer in Decay Heat Exchanger of Sodium-cooled Fast Reactor
Sodium-to-sodium heat exchangers such as the decay heat exchanger (DHX) are key components of the prototype generation [V sodium-cooled fast reactor (PGSFR). The DHX transfers the decay heat generated in the reactor core to the decay heat removal loop after a reactor shutdown. Shell-and-tube type with straight tube arrangement has been widely adopted for the sodium-to-sodium heat exchanger of the sodium-cooled fast reactor. Thus liquid metal heat transfer characteristics inside the tube and around the tube bundle have to be fully understood to design the sodium-to-sodium heat exchanger and evaluate its thermal performance accurately. Plenty of studies on the convective heat transfer of the liquid metals were conducted to present the Nusselt number (Nu) correlations with respect to the Peclet number (Pe). However, those correlations still deviated from each other considerably and few of correlations for low Pe range (less than 100) have been reported. Accordingly, it is difficult for a design code developer to choose a proper heat transfer coefficient correlation for the sodium-to-sodium heat exchanger particularly in a low flow rate range. Recently, a separate effect test for the DHX has been completed using the STELLA-1 facility at KAERI according to the STELLA program which aims at establishment of separate and integral test database (DB) for the design of the PGSFR. The heat transfer performance test of the DHX was successfully conducted under major operating conditions. The objective of this work is to suggest proper convective heat transfer correlations for tube- and shell-sides of the sodium-to-sodium heat exchanger based on the test DB obtained from STELLA-1. The Pe range of the analyzed experimental data is concentrated on less then 100. The adequacy of the suggested correlations is evaluated by applying to the DHX design code, SHXSA. Based on the DHX test DB of the STELLA-1, the proper convective heat transfer correlations for the tube- and shell-side of sodium-to-sodium heat exchangers were suggested. Two correlation combinations for each side were proposed and turned out to be reasonable through the evaluation using the SHXSA design code: Suggestion no. 1: - Lyon correlation (constant = 4) for tube-side; - Lubarsky-Kaufman correlation for shell-side. Suggestion no. 2: - Modified Lyon correlation (constant = 1.45) for tube-side; - Schad-modified correlation for shell-side The Pe ranges of the DHX test DB were 53 - 225 for the tube-side and 45 - 148 for the shell-side, but most of test conditions were concentrated on the Pe range of less than 100. Two correlation suggestions can be practically used for the design of sodium-to-sodium heat exchangers. However, by utilizing more test DB, it needs to be verified which one is closer to real phenomena. (authors)