At least 1,747 records · Page 97

Solar Array in Simulated LEO Plasma Environment

Six different types of solar arrays have been tested in large vacuum chambers. The low Earth orbit plasma environment was simulated in plasma vacuum chambers, where the parameters could be controlled precisely. Diagnostic equipment included spherical Langmuir probes, mass spectrometer, low-noise CCD camera with optical spectrometer, video camera, very sensitive current probe to measure arc current, and a voltage probe to register variations in a conductor potential. All data (except video) were obtained in digital form that allowed us to study the correlation between external parameters (plasma density, additional capacitance, bias voltage, etc) and arc characteristics (arc rate, arc current pulse width and amplitude, gas species partial pressures, and intensities of spectral lines). Arc inception voltages, arc rates, and current collections are measured for samples with different coverglass materials and thickness, interconnect designs, and cell sizes. It is shown that the array with wrapthrough interconnects have the highest arc threshold and the lowest current collection. Coverglass design with overhang results in decrease of current collection and increase of arc threshold. Doubling coverglass thickness causes the increase in arc inception voltage. Both arc inception voltage and current collection increase significantly with increasing a sample temperature to 80 C. Sustained discharges are initiated between adjacent cells with potential differences of 40 V for the sample with 300 m coverglass thickness and 60 V for the sample with 150 m coverglass thickness. Installation of cryogenic pump in large vacuum chamber provided the possibility of considerable outgassing of array surfaces which resulted in significant decrease of arc rate. Arc sites were determined by employing a video-camera, and it is shown that the most probable sites for arc inception are triple-junctions, even though some arcs were initiated in gaps between cells. It is also shown that the arc rate increases with increasing of ion collection current. The analysis of optical spectra (240-800 nm) reveals intensive narrow atomic lines (Ag, H) and wide molecular bands (OH, CH, SiH, SiN) that confirms a complicated mechanism of arc plasma generation. The results obtained seem to be important for the understanding of the arc inception mechanism, which is absolutely essential for progress toward the design of high-voltage solar array for space application.

Vayner, Boris↗

Design of an Airborne Portable Remote Imaging Spectrometer (PRISM) for the Coastal Ocean

PRISM is a pushbroom imaging spectrometer currently under development at the Jet Propulsion Laboratory, intended to address the needs of airborne coastal ocean science research. We describe here the instrument design and the technologies that enable it to achieve its distinguishing characteristics. PRISM covers the 350-1050 nm range with a 3.1 nm sampling and a 33(deg) field of view. The design provides for high signal to noise ratio, high uniformity of response, and low polarization sensitivity. The complete instrument also incorporates two additional wavelength bands at 1240 and 1610 nm in a spot radiometer configuration to aid with atmospheric correction.

imaging spectroscopy↗

Pre-Mission Input Requirements to Enable Successful Sample Collection by A Remote Field/EVA Team

The FINESSE (Field Investigations to Enable Solar System Science and Exploration) team, part of the Solar System Exploration Virtual Institute (SSERVI), is a field-based research program aimed at generating strategic knowledge in preparation for human and robotic exploration of the Moon, near-Earth asteroids, Phobos and Deimos, and beyond. In contract to other technology-driven NASA analog studies, The FINESSE WCIS activity is science-focused and, moreover, is sampling-focused with the explicit intent to return the best samples for geochronology studies in the laboratory. We used the FINESSE field excursion to the West Clearwater Lake Impact structure (WCIS) as an opportunity to test factors related to sampling decisions. We examined the in situ sample characterization and real-time decision-making process of the astronauts, with a guiding hypothesis that pre-mission training that included detailed background information on the analytical fate of a sample would better enable future astronauts to select samples that would best meet science requirements. We conducted three tests of this hypothesis over several days in the field. Our investigation was designed to document processes, tools and procedures for crew sampling of planetary targets. This was not meant to be a blind, controlled test of crew efficacy, but rather an effort to explicitly recognize the relevant variables that enter into sampling protocol and to be able to develop recommendations for crew and backroom training in future endeavors.

FINESSE↗

On Ambiguities in SAR Design

Ambiguities are an aliasing effect caused by the periodic sampling of the scene backscatter inherent to pulsed radar systems such as Synthetic Aperture radar (SAR). In this paper we take a fresh look at the relationship between SAR range and azimuth ambiguity constraints on the allowable pulse repetition frequency (PRF) and the antenna length. We show that for high squint angles smaller antennas may be feasible in some cases. For some applications, the ability to form a synthetic aperture at high squint angles is desirable, but the size of the antenna causes problems in the design of systems capable of such operation. This is because the SAR system design is optimized for a side-looking geometry. In two examples design examples we take a suboptimum antenna size and examine the performance in terms of azimuth resolution and swath width as a function of squint angle. We show that for stripmap SARs, the swath width is usually worse for off-boresight squint angles, because it is severely limited by range walk, except in cases where we relax the spatial resolution. We consider the implications for the design of modest-resolution, narrow swath, scanning SAR scatterometers .

Synthetic Aperture radar (SAR)↗

DIY XES-development of an inexpensive, versatile, and easy to fabricate XES analyzer and sample delivery system

The application of X-ray emission spectroscopy (XES) has grown substantially with the development of X-ray free-electron lasers, third and fourth generation synchrotron sources, and high-power benchtop sources. By providing the high X-ray flux required for XES, these sources broaden the availability and application of this method of probing electronic structure. As the number of sources increase, so does the demand for X-ray emission detection and sample delivery systems that are cost effective and customizable. In this work, we present a detailed fabrication protocol for von Hamos X-ray optics and give details for a 3D-printed spectrometer design. Additionally, we outline an automated, externally triggered liquid sample delivery system that can be used to repeatedly deliver nanoliter droplets onto a plastic substrate for measurement. These systems are both low cost, efficient, and easy to recreate or modify depending on the application. A low cost multiple X-ray analyzer system enables measurement of dilute samples, whereas the sample delivery limits sample loss and reproducibly replaces spent sample with fresh sample in the same position. While both systems can be used in a wide range of applications, the design addresses several challenges associated specifically with time-resolved XES (TRXES). As an example application, we show results from TRXES measurements of photosystem II, a dilute, photoactive protein.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and simulation of a descent controller for strategic four-dimensional aircraft navigation

A time-controlled navigation system applicable to the descent phase of flight for airline transport aircraft was developed and simulated. The design incorporates the linear discrete-time sampled-data version of the linearized continuous-time system describing the aircraft's aerodynamics. Using optimal linear quadratic control techniques, an optimal deterministic control regulator which is implementable on an airborne computer is designed. The navigation controller assists the pilot in complying with assigned times of arrival along a four-dimensional flight path in the presence of wind disturbances. The strategic air traffic control concept is also described, followed by the design of a strategic control descent path. A strategy for determining possible times of arrival at specified waypoints along the descent path and for generating the corresponding route-time profiles that are within the performance capabilities of the aircraft is presented. Using a mathematical model of the Boeing 707-320B aircraft along with a Boeing 707 cockpit simulator interfaced with an Adage AGT-30 digital computer, a real-time simulation of the complete aircraft aerodynamics was achieved. The strategic four-dimensional navigation controller for longitudinal dynamics was tested on the nonlinear aircraft model in the presence of 15, 30, and 45 knot head-winds. The results indicate that the controller preserved the desired accuracy and precision of a time-controlled aircraft navigation system.

Lax, F. M.↗

A Multi-Armed Bayesian Ordinal Outcome Utility-Based Sequential Trial with a Pairwise Null Clustering Prior

A multi-armed trial based on ordinal outcomes is proposed that leverages a flexible non-proportional odds cumulative logit model and numerical utility scores for each outcome to determine treatment optimality. This trial design uses a Bayesian clustering prior on the treatment effects that encourages the pairwise null hypothesis of no differences between treatments. A group sequential design is proposed to determine which treatments are clinically different with an adaptive decision boundary that becomes more aggressive as the sample size or clinical significance grows, or the number of active treatments decreases. A simulation study is conducted for 3 and 5 treatment arms, which shows that the design has superior operating characteristics (family wise error rate, generalized power, average sample size) compared to utility designs that do not allow clustering, a frequentist proportional odds model, or a permutation test based on empirical mean utilities.

97 MATHEMATICS AND COMPUTING↗

Design of Neural Networks for Fast Convergence and Accuracy

A novel procedure for the design and training of artificial neural networks, used for rapid and efficient controls and dynamics design and analysis for flexible space systems, has been developed. Artificial neural networks are employed to provide a means of evaluating the impact of design changes rapidly. Specifically, two-layer feedforward neural networks are designed to approximate the functional relationship between the component spacecraft design changes and measures of its performance. A training algorithm, based on statistical sampling theory, is presented, which guarantees that the trained networks provide a designer-specified degree of accuracy in mapping the functional relationship. Within each iteration of this statistical-based algorithm, a sequential design algorithm is used for the design and training of the feedforward network to provide rapid convergence to the network goals. Here, at each sequence a new network is trained to minimize the error of previous network. The design algorithm attempts to avoid the local minima phenomenon that hampers the traditional network training. A numerical example is performed on a spacecraft application in order to demonstrate the feasibility of the proposed approach.

Maghami, Peiman G.↗

Ground Tests of High-Voltage Solar Arrays Immersed in a Low Density Plasma

Five different types of solar arrays have been tested in large vacuum chamber. Arc inception voltages, arc rates, and current collections are measured for samples with different coverglass materials and thickness, interconnect designs, and cell sizes. It is shown that the array with wrapthrough interconnects have the highest arc threshold and the lowest current collection. Coverglass design with overhang results in decrease of current collection and increase of arc threshold. Doubling coverglass thickness does not improve measured array parameters. Both arc inception voltage and current collection increase significantly with increasing a sample temperature to 80 C. Sustained discharges are initiated between adjacent cells with potential differences of 40 V for the sample with 300 pm coverglass thickness and 60 V for the sample with 150 urn coverglass thickness.

Vayner, Boris↗

Overcoming the sensitivity vs. throughput tradeoff in Coulter counters: A novel side counter design

We report microfabricated Coulter counters are attractive for point of care (POC) applications since they are label free and compact. However, these approaches inherently suffer from a trade off between sample throughput and sensitivity. The counter measures a change in impedance due to displaced fluid volume by passing cells, and thus the counter's signal increases with the fraction of the sensing volume displaced. Reducing the size of the sensing region requires reductions in volumetric throughput in the absence of increased hydraulic pressure and sensor bandwidth. The risk of mechanical clog formation, rendering the counter inoperable, increases markedly with reductions in the size of the constriction aperture. We present here a microfluidic coplanar Coulter counter device design that overcomes the problem of constriction clogging while capable of operating in microfluidic channels filled entirely with highly conductive sample. The device utilizes microfabricated planar electrodes projecting into one side of the microfluidic channel and is easily integrated with upstream electronic, hydrodynamic, or other focusing units to produce efficient counting which could allow for dramatically increased volumetric and sample throughput. The design lends itself to simple, cost effective POC applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New Insights into Prebiotic Chemistry from Old Archived Miller Extracts

Following the discovery of an archived set of samples from Stanley Miller's early experiments, analyses were undertaken to better understand the diversity of compounds produced from electric discharges acting on reducing gas mixtures. The paper chromatography methods that Miller used in the 1950s were only capable of detecting a few amino acids and were unable to provide substantial quantitative data relative to today's techniques. Current analytical techniques are much more sensitive and selective, and are capable of precisely quantifying a much larger range of amino acids and their enantiomeric abundances. In one study, preserved dried samples produced by Miller using a lesser-known volcanic apparatus which differed from Miller's classic apparatus in that it utilized an aspirator that injected steam into the electric discharge chamber, simulating a volcanic eruption. The volcanic apparatus produced a wider variety of amino acids than the classic configuration. Prebiotic compounds synthesized in these environments may have locally accumulated where they could have undergone further processing. An additional preserved set of samples from an experiment conducted in 1958 were also found in Miller's archived collection. These samples which had been generated using a mixture of CH4, NH3, H2S and CO2 were collected, catalogued, and stored by Miller, but for unknown reasons were never studied. In our analyses a total of 23 amino acids and 4 amines, including 7 organosulfur compounds, were detected in these samples. The major amino acids with chiral centers are racemic within the accuracy of the measurements, indicating that they are not contaminants introduced during sample storage. This experiment marks the first synthesis of sulfur amino acids from spark discharge experiments designed to imitate primordial environments. The relative yield of some amino acids, in particular the isomers of amino butyric acid, are the highest ever found in a spark discharge experiment. The simulated primordial conditions used by Miller in these experiments may serve as a model for early volcanic plume chemistry and provide insight to the possible roles such plumes may have played in abiotic organic synthesis. Additionally, the overall abundances of the synthesized amino acids in the presence of H2S are very similar to the abundances found in some carbonaceous meteorites, suggesting that H2S may have played an important role in prebiotic reactions in early solar system environments. Although experiments using a variety of gases as components of the primordial Earth's atmospheric composition and a spark discharge apparatus configured according to Miller's original or volcanic design can be readily carried out, the unique opportunity to investigate samples prepared by the pioneer in abiotic synthesis using state of the art analytical methods is of considerable historic interest.

Parker, Eric T.↗

Benchmarking Computational Tools for Calling SNPs and Indels in Complex Microbial Populations

The NASA BioNutrients missions seek to understand the suitability of microorganisms for bioproduction during space flight. One topic of interest is the stability of microbial genomes during long-term ambient storage and subsequent rehydration and growth. To address these questions, samples from 8 species were flown to ISS for 5 years of desiccated storage at ambient temperature (Stasis Packs) and 2 species were packaged along with powdered media inside a bioreactor system to allow hydration and growth in microgravity (Production Packs). For both systems, Whole Genome Sequencing (WGS) of the DNA extracted from the returned samples and paired ground controls will be conducted to identify changes in genome stability due to time, storage conditions and growth in space. Across the technical replicates, ground controls, 10 timepoints, and multiple experimental conditions, ~300 samples have been selected for initial analysis with WGS sequencing to 100x coverage. A flexible and resource efficient mutation calling pipeline is needed to process this large dataset and allow for comparisons between species. Many bioinformatics tools for calling Indels and Single Nucleotide Variants (SNVs) are designed for use with pure isolates, where true variations from the reference genome are expected to dominate the reads aligning to the location of mutation. In contrast, DNA from the Stasis Pack (SP) samples was collected directly after recovery from desiccated storage and the Production Pack (PP) samples were collected after fermentation. In this context, reads with mutations are expected to be less frequent than reads that align with the reference genome, as each sample will include multiple lines of cells. Thus, BioNutrients samples are expected to be similar to samples from cancer cell or “pooled” sequencing approaches. In preparation for the analysis of the BioNutrients samples, we have tested three mutation calling tools (GATK for Microbes, BreSeq and DiscoSNP) designed for complex samples. A challenge of validating mutation identification pipelines is a lack of “Ground Truth” datasets, especially for complex samples. To compare these three tools, we sought to identify mutations in pre-existing WGS data collected from populations of Chlamydomonas reinhardtii that were exposed to UV mutagenesis and growth in LEO as part of the Space Algae-1 mission. Here we present a summary of these tools against the analysis originally conducted using the CRISP tool. Critical metrics are compared such as runtime, the number of SNPs, the number and size of Indels, and patterns of transversion and transitions identified by each tool are reported. By sharing these benchmarking results collected in support of the BioNutrients mission, we aim to guide others seeking to identify SNVs in similarly complex microbial samples.

Biology↗

Passive Thermal Coating Observatory Operating in Low-Earth Orbit (PATCOOL) – Cubesat Design to Test Passive Thermal Coatings in Space

The PATCOOL is a NASA sponsored, University of Florida developed 3U Cu-beSat meant to investigate the feasibility of using a cryogenic selective surface coating as a new, more efficient way of passively cooling components in space. Initial tests on the ground demonstrate that this coating should provide a much higher reflectance of the Sun’s irradiant power than any existing coating, while still providing far-infrared power emission. The ultimate validation of this tech-nology requires on-orbit testing. PATCOOL hosts a 4-sample housing, with the samples shaped as thin cylinders (coin-like). Two samples are coated with state-of-the-art material, while the other pair uses the new coating to be evaluated. The temperatures of all samples during the mission (minimum 72 hours of data col-lection) are measured via thermistors. The samples are connected via thin Kevlar strings to the housing, to minimize heat transfer. The housing is designed to shield the samples from Earth’s thermal radiation, and the CubeSat is attitude stabilized and controlled via a gravity gradient boom, magnetorquers and a reaction wheel set. Thermal Desktop simulations show PATCOOL’s ability to thermally isolate the samples from heat exchanges other than with Sun and deep space, thanks to its thermal design and the chosen attitude profile.

Ojeda, Carlos↗

The Low Temperature Microgravity Physics Experiments Project

The Low Temperature Microgravity Physics Facility (LTMPF) is being developed by NASA to provide long duration low temperature and microgravity environment on the International Space Station (ISS) for performing fundamental physics investigations. Currently, six experiments have been selected for flight definition studies. More will be selected in a two-year cycle, through NASA Research Announcement. This program is managed under the Low Temperature Microgravity Physics Experiments Project Office at the Jet Propulsion Laboratory. The facility is being designed to launch and returned to earth on a variety of vehicles including the HII-A and the space shuttle. On orbit, the facility will be connected to the Exposed Facility on the Japanese Experiment Module, Kibo. Features of the facility include a cryostat capable of maintaining super-fluid helium at a temperature of 1.4 K for 5 months, resistance thermometer bridges, multi-stage thermal isolation system, thermometers capable of pico-Kelvin resolution, DC SQUID magnetometers, passive vibration isolation, and magnetic shields with a shielding factor of 80dB. The electronics and software architecture incorporates two VME buses run using the VxWorks operating system. Technically challenging areas in the design effort include the following: 1) A long cryogen life that survives several launch and test cycles without the need to replace support straps for the helium tank. 2) The minimization of heat generation in the sample stage caused by launch vibration 3) The design of compact and lightweight DC SQUID electronics. 4) The minimization of RF interference for the measurement of heat at pico-Watt level. 5) Light weighting of the magnetic shields. 6) Implementation of a modular and flexible electronics and software architecture. The first launch is scheduled for mid-2003, on an H-IIA Rocket Transfer Vehicle, out of the Tanegashima Space Center of Japan. Two identical facilities will be built. While one facility is onboard the ISS, the other is re-integrated on the ground with new experiments. When the cryogen of the facility in space are exhausted, it will be swapped with the other facility with the new experiment. A total of 20 science missions are envisioned over the next 20 years.

Holmes, Warren↗

Delamination imaging in composites using cross-correlation method by non-contact air-coupled Lamb waves

Abstract This paper presents a cross-correlation damage detection technique using damage scattered waves of all directions cross-correlate with the incident waves for delamination imaging in carbon fiber reinforced polymer (CFRP) composite plate. The presented imaging can not only detect the delamination but also precisely quantify the damage with locations and sizes. First, a CFRP composite sample with interlaminar delamination by inserting the Teflon layer is designed and manufactured in house using the hot-press machine. And a three-dimensional model of composite sample is simulated using the finite element method. Next, the cross-correlation imaging algorithm is introduced in detail, and the cross-correlation imaging proof-of-concept study is conducted with the simulated Lamb waves in the composite sample. Finally, a fully non-contact air-coupled transducer and scanning laser Doppler vibrometer system with a single-mode Lamb wave method is established to actuate and sense the interrogating Lamb waves in the structure. The imaging method is experimentally implemented for the one delamination and two delaminations imaging and quantification.

Instruments & Instrumentation↗

Steps to achieving high-resolution NMR spectroscopy on solutions at GPa pressure

Recent theoretical advances and molecular-dynamic estimates of the dielectric constant of water have extended the HKF model for aqueous solution chemistry up to 6.0 gigapascals (GPa), which are conditions well beyond the capabilities of conventional NMR spectroscopy (Pan et al., 2013; Sverjensky et al., 2014, see also Wasserman and others, 1995). These developments provide strong motivation to design a simple NMR probe that allows experiments on solutions, at high resolution, to pressures of a few GPa (Pautler et al., 2014; Ochoa et al., 2015; 2016). Here we describe the performance of a compact NMR probe that can reach several GPa pressures. The probe is made by placing a solenoid microcoil inside of a standard piston-cylinder device used in solid-state physics. High pressures are achieved in the sample by applying force to a coaxial piston. Early designs of the probe, although useful, were limited in sample size to ~10-15μL. Here we describe modifications that allow greatly improved resolution and sensitivity, including 1H-1H NMR correlation spectroscopy, on solutions at 2.8 GPa pressure. Sample sizes can be expanded if, instead of a standard NMR spectrometer that is built around a superconducting magnet, one employs a magnetic-resonance imaging (MRI) system that is built around a permanent magnet. The MRI systems can apply larger magnetic field gradients than conventional spectrometers, and thus have more robust shimming capability, which is needed because of the juxtaposition of different alloys in the pressure cell. More importantly, these systems can have magnetic fields that are oriented perpendicular to the magnet bore, which allows rotation of the coil within the axis of the pressure cell to increase sample volumes and pressure. Sensitivity is improved by replacing the traditional, but reduced-volume, closed sample container mounted in the center of the NMR detection coil with an open NMR coil that dangles freely in solution, thus making the sample solution itself the pressure-transmission fluid. The efficacy of these modifications are demonstrated by measuring 1 H NMR spectra for ethyl alcohol and ethyl alcohol/methyl alcohol mixtures at pressures up to 2.8 GPa. As a result, further developments are discussed that will allow geochemists to acquire aqueous solution NMR spectra at higher 3-4 GPa pressures.

58 GEOSCIENCES↗

A comparison of Raman and pyrometry dynamic temperature measurements of shocked cyclohexane

Optical pyrometry is a well-developed, broadly applicable method to determine temperature in dynamic compression experiments. However, it measures radiation from only the skin depth of the radiant material, is highly susceptible to spurious backgrounds, and requires an often-unmeasurable free parameter—the sample dynamic emissivity. Raman spectroscopy offers a method to determine temperature directly from fundamental theory, but it is practically limited in applications to a small subset of shock experiments. In this work, we describe an experiment allowing simultaneous application of Raman and pyrometric temperature techniques to benchmark a specific instance of pyrometry. We attempted both measurements on multiple experiments and compare the successful temperature results between the separate but highly repeatable shots. Here, we find that dynamic shock temperatures inferred from Raman spectroscopy and pyrometry generally agree within the uncertainties of each measurement, although those uncertainties are larger than typical for a specially designed pyrometry experiment on a shocked metal sample.

74 ATOMIC AND MOLECULAR PHYSICS↗

Development of a vadose zone advanced monitoring system: Tools to assess groundwater vulnerability

Performing repeat pore-fluid sampling over long time-scales can provide valuable information on unsaturated zone contaminants and their potential flux to ground water. This information can be used to manage groundwater remedies and identify contaminants that need to be sequestered in the vadose zone to minimize flux to ground water. Pore-water samples are commonly used to obtain contaminant concentrations within the vadose zone, but existing methods are limited as they only provide a single sample at one location and time. The vadose zone advanced monitoring system (VZAMS) has been designed to integrate multiple technologies into a single down-borehole system that allows for sampling of pore fluids (liquid and gas) to provide information about contamination and hydraulic conditions at multiple depths (~0.3-m intervals) within a cased borehole. Testing has been completed at the laboratory scale to verify the sampling elements of VZAMS, including geochemical testing for representative contaminants known to exist at the Hanford Site, located in southeastern Washington State. Physical tests focused on the ability of the sampler to draw fluid under unsaturated conditions. Initial geochemical testing showed that the stainless steel material used with the porous cuff may affect the sampled concentrations of redox-sensitive contaminants under very dry conditions. Additional laboratory testing demonstrated that the VZAMS components are able to collect representative samples for substances of interest under expected field conditions. In this paper, the design and functionality of a novel instrument are demonstrated in support of subsequent testing in the field.

54 ENVIRONMENTAL SCIENCES↗