Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Projection of angular momentum via linear algebra

Projection of many-body states with good angular momentum from an initial state is usually accomplished by a three-dimensional integral. Here, we show how projection can instead be done by solving a straightforward system of linear equations. We demonstrate the method and give sample applications to $^{48}$Cr and $^{60}$Fe in the $pf$ shell. This new projection scheme, which is competitive against the standard numerical quadrature, should also be applicable to other quantum numbers such as isospin and particle number.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Top quark mass measurement using the template method at CDF

We present a measurement of the top quark mass in the lepton+jets and dilepton channels of t$\bar{t}$ decays using the template method. The data sample corresponds to an integrated luminosity of 5.6 fb -1 of p$\bar{p}$ collisions at Tevatron with √s = 1.96 TeV, collected with the CDF II detector. The measurement is performed by constructing templates of three kinematic variables in the lepton+jets and two kinematic variables in the dilepton channel. The variables are two reconstructed top quark masses from different jets-to-quarks combinations and the invariant mass of two jets from the W decay in the lepton+jets channel, and a reconstructed top quark mass and m T2 , a variable related to the transverse mass in events with two missing particles, in the dilepton channel. The simultaneous fit of the templates from signal and background events in the lepton+jets and dilepton channels to the data yields a measured top quark mass of M top = 172.1±1.1 (stat)±0.9 (syst) GeV/c 2 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Renormalization group computation of likelihood functions for cosmological data sets

I show how a renormalization group (RG) method can be used to incrementally integrate the information in cosmological large-scale structure data sets (including CMB, galaxy redshift surveys, etc.). I show numerical tests for Gaussian fields, where the method allows arbitrarily close to exact computation of the likelihood function in order N time, even for problems with no symmetry, compared to N 3 for brute force linear algebra (where N is the number of data points - to be fair, methods already exist to solve the Gaussian problem in at worst N log N time, and this method will not necessarily be faster in practice). The method requires no sampling or other Monte Carlo (random) element. Nonlinearity/non-Gaussianity can be accounted for to the extent that terms generated by integrating out small scale modes can be projected onto a sufficient basis, e.g., at least in the sufficiently perturbative regime. The formulas to evaluate are straightforward and require no understanding of quantum field theory, but this paper may also serve as a pedagogical introduction to Wilsonian RG for astronomers.

79 ASTRONOMY AND ASTROPHYSICS↗

Complementarity of neutron, XFEL and synchrotron crystallography for defining the structures of metalloenzymes at room temperature

Room-temperature macromolecular crystallography allows protein structures to be determined under close-to-physiological conditions, permits dynamic freedom in protein motions and enables time-resolved studies. In the case of metalloenzymes that are highly sensitive to radiation damage, such room-temperature experiments can present challenges, including increased rates of X-ray reduction of metal centres and site-specific radiation-damage artefacts, as well as in devising appropriate sample-delivery and data-collection methods. It can also be problematic to compare structures measured using different crystal sizes and light sources. In this study, structures of a multifunctional globin, dehaloperoxidase B (DHP-B), obtained using several methods of room-temperature crystallographic structure determination are described and compared. Here, data were measured from large single crystals and multiple microcrystals using neutrons, X-ray free-electron laser pulses, monochromatic synchrotron radiation and polychromatic (Laue) radiation light sources. These approaches span a range of 18 orders of magnitude in measurement time per diffraction pattern and four orders of magnitude in crystal volume. The first room-temperature neutron structures of DHP-B are also presented, allowing the explicit identification of the hydrogen positions. The neutron data proved to be complementary to the serial femtosecond crystallography data, with both methods providing structures free of the effects of X-ray radiation damage when compared with standard cryo-crystallography. Comparison of these room-temperature methods demonstrated the large differences in sample requirements, data-collection time and the potential for radiation damage between them. With regard to the structure and function of DHP-B, despite the results being partly limited by differences in the underlying structures, new information was gained on the protonation states of active-site residues which may guide future studies of DHP-B.

36 MATERIALS SCIENCE↗

Statistical Generation of Ocean Forcing With Spatiotemporal Variability for Ice Sheet Models

Melting of ice at the base of floating ice shelves that fringe the Antarctic ice sheet has been identified as a significant source of uncertainty in sea level rise projections. Part of this uncertainty derives from chaotic internal variability of the coupled ocean-atmosphere system. For numerical ice sheet model projections, this uncertainty has not previously been quantified because of the prohibitive computational expense of running large climate model ensembles. Here, we develop and demonstrate a technique that generates independent realizations of internal climate variability from a single climate model simulation. Building on previous developments in model emulation, this technique uses empirical orthogonal function decomposition and Fourier-phase randomization to generate statistically consistent realizations of spatiotemporal variability fields for the target climate variable. The method facilitates efficient sampling of a wide range of climate trajectories, which can also be incorporated within ice sheet or other physical models to represent feedback processes.

54 ENVIRONMENTAL SCIENCES↗

Dielectric breakdown of additively manufactured polymeric materials

Dielectric strength testing of selected Polyjet-printed polymer plastics was performed in accordance with ASTM D149. This dielectric strength data is compared to manufacturer-provided dielectric strength data for selected plastics printed using the stereolithography (SLA), fused deposition modeling (FDM), and selective laser sintering (SLS) methods. Tested Polyjet samples demonstrated dielectric strengths as high as 47.5 kV/mm for a 0.5 mm thick sample and 32.1 kV/mm for a 1.0 mm sample. As a result, the dielectric strength of the additively manufactured plastics evaluated as part of this study was lower than the majority of non-printed plastics by at least 15% (with the exception of polycarbonate).

36 MATERIALS SCIENCE↗

Effects of Aluminum Plate Initial Residual Stress on Machined-Part Distortion

Dimensional tolerances for high-speed-machined aluminum products continue to tighten due to the demand for automated assembly of complex monolithic parts in aerospace and other industries. Understanding the contribution of inherent residual stress in wrought Al 7050-T7451 plate, common in aircraft manufacture, to distortion of high-aspect-ratio machined parts is critical but remains problematic due to the alloy's low residual stress magnitude over large geometries. Prior investigations into residual stress effects on machined part distortion suffer inadequate characterizations of the wrought material stress field, either because of low fidelity due to “slitting” methods, confounding effects in machined-layer removal methods, or small sample size when using neutron diffraction (ND). In this work, inherent residual stress is measured via ND at 860 locations in a 90.5 mm thick Al 7050-T7451 plate having dimensions 399 mm in the rolling direction and 335 mm in the transverse direction. Unlike prior studies, the ND residual stress is reconstructed using an iterative algorithm to ensure fully compatible, equilibrated 3D field prior to examining its effect on distortion. Further, the findings from simulations and experiments show that inherent residual stress alone could distort a high-aspect-ratio part beyond aerospace industry requirements, that slitting measurements may not sufficiently characterize residual stress for predicted distortion, and that parts machined from different plate thickness locations could exhibit reversed distortion patterns. Thus, research into distortion prediction that considers machining should carefully characterize and reconstruct inherent residual stress so that the coupled machining effects are accurately modeled.

36 MATERIALS SCIENCE↗

Properties of HfLaO MOS capacitor deposited on SOI with plasma enhanced atomic layer deposition

Amorphous HfLaO dielectric film was successfully deposited on a silicon-on-insulator (SOI) substrate by plasma enhanced atomic layer deposition with in situ plasma treatment. The HfLaO film retained its insulating characteristics and is thermally stable even after annealing at 800 °C. The film has a dielectric constant of 27.3 and leakage of only 0.03 mA/cm{sup 2} at a gate bias of |Vg − V{sub fb}| = 1 V. The capacitance equivalent oxide thickness is 0.7 nm. A new parallel electrode testing structure was applied to measure C–V and J–V characteristics for the SOI samples. This testing method for metal–oxide–semiconductor capacitors has potential uses for measuring other layered substrates.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Techniques to improve the accuracy of noise power spectrum measurements in digital x-ray imaging based on background trends removal

Purpose: Noise characterization through estimation of the noise power spectrum (NPS) is a central component of the evaluation of digital x-ray systems. Extensive works have been conducted to achieve accurate and precise measurement of NPS. One approach to improve the accuracy of the NPS measurement is to reduce the statistical variance of the NPS results by involving more data samples. However, this method is based on the assumption that the noise in a radiographic image is arising from stochastic processes. In the practical data, the artifactuals always superimpose on the stochastic noise as low-frequency background trends and prevent us from achieving accurate NPS. The purpose of this study was to investigate an appropriate background detrending technique to improve the accuracy of NPS estimation for digital x-ray systems. Methods: In order to achieve the optimal background detrending technique for NPS estimate, four methods for artifactuals removal were quantitatively studied and compared: (1) Subtraction of a low-pass-filtered version of the image, (2) subtraction of a 2-D first-order fit to the image, (3) subtraction of a 2-D second-order polynomial fit to the image, and (4) subtracting two uniform exposure images. In addition, background trend removal was separately applied within original region of interest or its partitioned sub-blocks for all four methods. The performance of background detrending techniques was compared according to the statistical variance of the NPS results and low-frequency systematic rise suppression. Results: Among four methods, subtraction of a 2-D second-order polynomial fit to the image was most effective in low-frequency systematic rise suppression and variances reduction for NPS estimate according to the authors' digital x-ray system. Subtraction of a low-pass-filtered version of the image led to NPS variance increment above low-frequency components because of the side lobe effects of frequency response of the boxcar filtering function. Subtracting two uniform exposure images obtained the worst result on the smoothness of NPS curve, although it was effective in low-frequency systematic rise suppression. Subtraction of a 2-D first-order fit to the image was also identified effective for background detrending, but it was worse than subtraction of a 2-D second-order polynomial fit to the image according to the authors' digital x-ray system. Conclusions: As a result of this study, the authors verified that it is necessary and feasible to get better NPS estimate by appropriate background trend removal. Subtraction of a 2-D second-order polynomial fit to the image was the most appropriate technique for background detrending without consideration of processing time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-534: Level of Residual Radioactivity of Activated Parts of a Decommissioned Cyclotron

Purpose: CTI cyclotron RDS-111 was used at the Hong Kong Sanatorium and Hospital (HKSH) to produce radiopharmaceuticals and radioactive tracers for diagnostic scans between 1999 and 2007. During the operation, some machine components became radioactive by activation. For the safety of staff, decommissioning took place in 2009, two years after the cyclotron had stopped operation. This study investigates the residual radioactivity and radionuclides found in different cyclotron components in 2014 in compliance with the local regulations in Hong Kong for transfer of radioactive waste. Methods: A representative sample of each part was counted using a high-purity germanium detector (manufacturer: ORTECT) for at least four hours. GammaVision, a multichannel analyzer software, was used to identify the radionuclides found in the cyclotron components, as well as the associated activities. A standard library and a Mariscotti peak search algorithm were used to identify the present radionuclides. Only radionuclides with half-life greater than 180 days were considered. Results: Among the components, the Havar target foil has the highest specific activity ((4.6±0.6)×10{sup 2} Bq/g), with Co-60 being the most prominent ((3.8±0.5)×10{sup 2} Bq/g). The total activity of the target foil, however, is still low due to its small mass of 0.04 g. Radioisotopes Mn-54 (46±6 Bq/g), Na-22 (6.8±0.8 Bq/g), Co-57 (7.3±0.9 Bq/g), and Fe-59 (6.0±0.9 Bq/g) have also been detected in the target foil. The target window holder and the vacuum window register a specific activity of 88.3±0.6 Bq/g and 48.6±0.1 Bq/g, respectively. Other components, such as the collimator, the target tube, the valve body and the beamline, are also found with trace amounts of radionuclides. Conclusion: Even seven years after the cyclotron had stopped operation, some components still exhibited residual radioactivity from activation exceeding the IAEA clearance levels. Special consideration for radiological protection may need to be taken in the disposal of the cyclotron parts.

07 ISOTOPE AND RADIATION SOURCES↗

Calibration of GafChromic EBT3 for absorbed dose measurements in 5 MeV proton beam and {sup 60}Co γ-rays

Purpose: To study EBT3 GafChromic film in low-energy protons, and for comparison purposes, in a reference {sup 60}Co beam in order to use it as a calibrated dosimetry system in the proton irradiation facility under construction within the framework of the Oncological Therapy with Protons (TOP)-Intensity Modulated Proton Linear Accelerator for RadioTherapy (IMPLART) Project at ENEA-Frascati, Italy. Methods: EBT3 film samples were irradiated at the Istituto Nazionale di Fisica Nucleare—Laboratori Nazionali di Legnaro, Italy, with a 5 MeV proton beam generated by a 7 MV Van de Graaff CN accelerator. The nominal dose rates used were 2.1 Gy/min and 40 Gy/min. The delivered dose was determined by measuring the particle fluence and the energy spectrum in air with silicon surface barrier detector monitors. A preliminary study of the EBT3 film beam quality dependence in low-energy protons was conducted by passively degrading the beam energy. EBT3 films were also irradiated at ENEA-National Institute of Ionizing Radiation Metrology with gamma radiation produced by a {sup 60}Co source characterized by an absorbed dose to water rate of 0.26 Gy/min as measured by a calibrated Farmer type ionization chamber. EBT3 film calibration curves were determined by means of a set of 40 film pieces irradiated to various doses ranging from 0.5 Gy to 30 Gy absorbed dose to water. An EPSON Expression 11000XL color scanner in transmission mode was used for film analysis. Scanner response stability, intrafilm uniformity, and interfilm reproducibility were verified. Optical absorption spectra measurements were performed on unirradiated and irradiated EBT3 films to choose the most sensitive color channel to the dose range used. Results: EBT3 GafChromic films show an under response up to about 33% for low-energy protons with respect to {sup 60}Co gamma radiation, which is consistent with the linear energy transfer dependence already observed with higher energy protons, and a negligible dose-rate dependence in the 2–40 Gy/min range. Short- and long-term scanner stabilities were 0.5% and 1.5%, respectively; film uniformity and reproducibility were better than 0.5%. Conclusions: The main purpose of this study was to implement EBT3 dosimetry in the proton low-energy radiobiology line of the TOP-IMPLART accelerator, having a maximum energy of 7 MeV. Low-energy proton and {sup 60}Co calibrated sources were used to investigate the behavior of film response vs to be written in italicum dose. The calibration in 5 MeV protons is currently used for dose assessment in the radiobiological experiments at the TOP-IMPLART accelerator carried out at that energy value.

60 APPLIED LIFE SCIENCES↗

Study of bound hydrogen in powders of diamond nanoparticles

In order to access feasibility of increasing albedo of very cold neutrons from powder of diamond nanoparticles, we studied hydrogen bound to surface of diamond nanoparticles, which causes unwanted losses of neutrons. We showed that one could decrease a fraction of hydrogen atoms from a ratio C{sub 7.4{+-}0.15}H to a ratio C{sub 12.4{+-}0.2}H by means of thermal treatment and outgasing of powder. Measurements of atomic excitation spectra of these samples, using a method of inelastic incoherent neutron scattering, indicate that residual hydrogen is chemically bound to carbon, while a removed fraction was composed of adsorbed water. The total cross section of scattering of neutrons with a wavelength of 4.4 Angstrom-Sign on residual hydrogen atoms equals 108 {+-} 2 b; it weakly changes with temperature. Thus preliminary cleaning of powder from hydrogen and its moderate cooling do not improve considerably neutron albedo from powder of nano-diamonds. An alternative approach is isotopic replacement of hydrogen by deuterium.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Probability characteristics of electrical noise in heterojunction light-emitting diodes

A hardware-software complex for measurements of the characteristics of electrical and optical noise in light-emitting diodes (LEDs) in the frequency range from 1 to 40 kHz is described. The electrical noise of several types of heterojunction-based LEDs are studied; these types include red-emission LEDs with AlInGaP/GaAs quantum wells and the green- and blue-emission LEDs with AlInGaN/SiC quantum wells are studied by the method of discrete samples. The spectra of all studied LEDs in the frequency range from 1 to 10 kHz have the form 1/f{sup {gamma}}. It is noteworthy that, for red-emission LEDs, the exponent {gamma} is significantly smaller than unity; this index is close to unity for the green- and blue-emission LEDs. The characteristic time of correlation of the noise of red-emission LEDs by several times exceeds the correlation times for the blue- and green-emission LEDs. It is shown that reduced functions of the amplitude distribution of the noise voltage are close to Gaussian functions with almost the same dispersion for all LED types.

36 MATERIALS SCIENCE↗

Structure and Properties of Zn-Implanted Si Near-Surface Layer Modification Depending on Irradiation Fluence of {sup 132}Xe{sup 26+} Ions with Energy of 167 MeV

Single-crystal n-Si(100) wafers are implanted with {sup 64}Zn{sup +} ions with an energy of 50 keV and dose of 5 × 10{sup 16} cm{sup –2}. Then the samples are irradiated with {sup 132}Xe{sup 26+} ions with an energy of 167 MeV in the range of fluences from 1 × 10{sup 12} to 5 × 10{sup 14} cm{sup –2}. The surface and cross section of the samples are visualized by scanning electron microscopy and transmission electron microscopy. The distribution of implanted Zn atoms is studied by time-of-flight secondary-ion mass spectrometry. After irradiation with Xe, surface pores and clusters consisting of a Zn–ZnO mixture are observed at the sample surface. In the amorphized subsurface Si layer, zinc and zinc-oxide phases are detected. After irradiation with Xe with a fluence of 5 × 10{sup 14} cm{sup –2}, no zinc or zinc-oxide clusters are detected in the samples by the methods used in the study.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

ATLAS $b$-jet identification performance and efficiency measurement with $t{\bar{t}}$ events in $pp$ collisions at $\sqrt{s}=13$

The algorithms used by the ATLAS Collaboration during Run 2 of the Large Hadron Collider to identify jets containing b-hadrons are presented. The performance of the algorithms is evaluated in the simulation and the efficiency with which these algorithms identify jets containing b-hadrons is measured in collision data. The measurement uses a likelihood-based method in a sample highly enriched in $t\bar{t}$ events. The topology of the t → Wb decays is exploited to simultaneously measure both the jet flavour composition of the sample and the efficiency in a transverse momentum range from 20 to 600 GeV. The efficiency measurement is subsequently compared with that predicted by the simulation. The data used in this measurement, corresponding to a total integrated luminosity of 80.5 fb -1 , were collected in proton–proton collisions during the years 2015–2017 at a centre-of-mass energy $ \sqrt{s}$ = 13 TeV. By simultaneously extracting both the efficiency and jet flavour composition, this measurement significantly improves the precision compared to previous results, with uncertainties ranging from 1 to 8% depending on the jet transverse momentum.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Unified many-worlds browsing of arbitrary physics-based animations

Manually tuning physics-based animation parameters to explore a simulation outcome space or achieve desired motion outcomes can be notoriously tedious. This problem has motivated many sophisticated and specialized optimization-based methods for fine-grained (keyframe) control, each of which are typically limited to specific animation phenomena, usually complicated, and, unfortunately, not widely used. In this paper, we propose Unified Many-Worlds Browsing (UMWB), a practical method for sample-level control and exploration of physics-based animations. Our approach supports browsing of large simulation ensembles of arbitrary animation phenomena by using a unified volumetric WORLDPACK representation based on spatiotemporally compressed voxel data associated with geometric occupancy and other low-fidelity animation state. Beyond memory reduction, the WORLDPACK representation also enables unified query support for interactive browsing: it provides fast evaluation of approximate spatiotemporal queries, such as occupancy tests that find ensemble samples ("worlds") where material is either IN or NOT IN a user-specified spacetime region. WORLDPACKS also support real-time hardware-accelerated voxel rendering by exploiting the spatially hierarchical and temporal RLE raster data structure. Our UMWB implementation supports interactive browsing (and offline refinement) of ensembles containing thousands of simulation samples, and fast spatiotemporal queries and ranking. We show UMWB results using a wide variety of physics-based animation phenomena---not just JELL-O ® .

Computer Science↗

pnnl/memgaze

MemGaze is a memory analysis toolset that combines high-resolution trace analysis and low overhead measurement, both with respect to time and space. It provides high-resolution by collecting world-level memory access traces, where the highest resolution supported is back-to-back sequences. It achieves low-overhead in space and time by leveraging sampling and various methods of hardware support for collecting traces. Its post-mortem trace processing provides multiresolution analysis for locations vs. operations; accesses vs. spatio-temporal reuse, and reuse (distance, rate, volume) vs. access patterns.

Central, PNNL Developer↗

DNA Methylation as a Biomarker for Preeclampsia

Background: Preeclampsia contributes significantly to pregnancy-associated morbidity and mortality as well as future risk of cardiovascular disease in mother and offspring, and preeclampsia in offspring. The lack of reliable methods for early detection limits the opportunities for prevention, diagnosis, and timely treatment. Purpose: The purpose of this study was to explore distinct DNA methylation patterns associated with preeclampsia in both maternal cells and fetal-derived tissue that represent potential biomarkers to predict future preeclampsia and inheritance in children. Method: A convenience sample of nulliparous women (N = 55) in the first trimester of pregnancy was recruited for this prospective study. Genome-wide DNA methylation was quantified in first-trimester maternal peripheral white blood cells and placental chorionic tissue from normotensive women and those with preeclampsia (n = 6/group). Results: Late-onset preeclampsia developed in 12.7% of women. Significant differences in DNA methylation were identified in 207 individual linked cytosine and guanine (CpG) sites in maternal white blood cells collected in the first trimester (132 sites with gain and 75 sites with loss of methylation), which were common to approximately 75% of the differentially methylated CpG sites identified in chorionic tissue of fetal origin. Conclusion: This study is the first to identify maternal epigenetic targets and common targets in fetal-derived tissue that represent putative biomarkers for early detection and heritable risk of preeclampsia. Findings may pave the way for diagnosis of preeclampsia prior to its clinical presentation and acute damaging effects, and the potential for prevention of the detrimental long-term sequelae.

biomarker↗