Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

A diagnosis of intense ion beam by CR-39 detectors analyzing the back scattered particles

A new diagnosis method has been developed utilizing back scattered particles for high energy intense ion beams. The CR-39 detector mounted on the uniform back-scatterer was irradiated with {sup 4}He{sup 2+} ions with an energy 25 MeV/n, which is never recorded as etchable track in CR-39. We found that it is possible to diagnose by analyzing the etch pits on the rear surface of CR-39 that directly contacted on the back-scatterers. It turns out that most of etch pits in the rear surface are made by the backscattered particles by investigating the growth pattern of each etch pit with multi-step etching technique. This method allows simple diagnosis of the ion beam profile and intensity distribution in mixed radiation field such as laser-driven ion acceleration experiments.

43 PARTICLE ACCELERATORS↗

The Midlatitude Continental Convective Clouds Experiment (MC3E) sounding network: operations, processing and analysis

The Midlatitude Continental Convective Clouds Experiment (MC3E) took place during the spring of 2011 centered in north-central Oklahoma, USA. The main goal of this field campaign was to capture the dynamical and microphysical characteristics of precipitating convective systems in the US Central Plains. A major component of the campaign was a six-site radiosonde array designed to capture the large-scale variability of the atmospheric state with the intent of deriving model forcing data sets. Over the course of the 46-day MC3E campaign, a total of 1362 radiosondes were launched from the enhanced sonde network. This manuscript provides details on the instrumentation used as part of the sounding array, the data processing activities including quality checks and humidity bias corrections and an analysis of the impacts of bias correction and algorithm assumptions on the determination of convective levels and indices. It is found that corrections for known radiosonde humidity biases and assumptions regarding the characteristics of the surface convective parcel result in significant differences in the derived values of convective levels and indices in many soundings. In addition, the impact of including the humidity corrections and quality controls on the thermodynamic profiles that are used in the derivation of a large-scale model forcing data set are investigated. The results show a significant impact on the derived large-scale vertical velocity field illustrating the importance of addressing these humidity biases.

54 ENVIRONMENTAL SCIENCES↗

Photoelectron emission from metal surfaces induced by radiation emitted by a 14 GHz electron cyclotron resonance ion source

Photoelectron emission measurements have been performed using a room-temperature 14 GHz ECR ion source. It is shown that the photoelectron emission from Al, Cu, and stainless steel (SAE 304) surfaces, which are common plasma chamber materials, is predominantly caused by radiation emitted from plasma with energies between 8 eV and 1 keV. Characteristic X-ray emission and bremsstrahlung from plasma have a negligible contribution to the photoelectron emission. It is estimated from the measured data that the maximum conceivable photoelectron flux from plasma chamber walls is on the order of 10% of the estimated total electron losses from the plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessing the impacts of assimilating IASI and MOPITT CO retrievals using CESM-CAM-chem and DART

We report on the results and evaluation with independent measurements from assimilating both MOPITT (Measurements Of Pollution In The Troposphere) and IASI (Infrared Atmospheric Sounding Interferometer) retrieved profiles into the Community Earth System Model (CESM). We used the Data Assimilation Research Testbed ensemble Kalman filter technique, with the full atmospheric chemistry CESM component Community Atmospheric Model with Chemistry. We first discuss the methodology and evaluation of the current data assimilation system with coupled meteorology and chemistry data assimilation. The various capabilities of MOPITT and IASI retrievals are highlighted, with specific attention to instrument vertical sensitivity and coverage and how these impact the analyses. MOPITT and IASI CO retrievals mostly constrain the CO fields close to the main anthropogenic, biogenic, and biomass burning CO sources. In the case of IASI CO assimilation, we also observe constraints on CO far from the sources. During the simulation time period (June and July 2008), CO assimilation of both instruments strongly improves the atmospheric CO state as compared to independent observations, with the higher spatial coverage of IASI providing better results on the global scale. Yet, the enhanced sensitivity of multispectral MOPITT observations to near surface CO over the main source regions provides synergistic effects at regional scales.

54 ENVIRONMENTAL SCIENCES↗

Astrophysical neutrinos and cosmic rays observed by IceCube

The core mission of the IceCube neutrino observatory is to study the origin and propagation of cosmic rays. IceCube, with its surface component IceTop, observes multiple signatures to accomplish this mission. Most important are the astrophysical neutrinos that are produced in interactions of cosmic rays, close to their sources and in interstellar space. IceCube is the first instrument that measures the properties of this astrophysical neutrino flux and constrains its origin. In addition, the spectrum, composition, and anisotropy of the local cosmic-ray flux are obtained from measurements of atmospheric muons and showers. Here we provide an overview of recent findings from the analysis of IceCube data, and their implications to our understanding of cosmic rays.

79 ASTRONOMY AND ASTROPHYSICS↗

Simulations of Winter Arctic Clouds and Associated Radiation Fluxes Using Different Cloud Microphysics Schemes in the Polar WRF: Comparisons With CloudSat, CALIPSO, and CERES

Clouds are important for the Arctic climate, but simulating such clouds with numerical models is still challenging. The accuracy of model clouds has not been sufficiently examined due to the harsh Arctic environment obstructing cloud observations, especially during Arctic winters experiencing polar nights. This study compares the Arctic winter clouds simulated by a weather forecast model to cloud observations from active (lidar and radar) satellite instruments. The model successfully produced cloud patterns similar to the satellite observations. However, the choice of the cloud physics module in the model can modify the amount of cloud water significantly enough to affect the simulated surface climate.

54 ENVIRONMENTAL SCIENCES↗

Quantum cascade laser investigations of CH{sub 4} and C{sub 2}H{sub 2} interconversion in hydrocarbon/H{sub 2} gas mixtures during microwave plasma enhanced chemical vapor deposition of diamond

CH{sub 4} and C{sub 2}H{sub 2} molecules (and their interconversion) in hydrocarbon/rare gas/H{sub 2} gas mixtures in a microwave reactor used for plasma enhanced diamond chemical vapor deposition (CVD) have been investigated by line-of-sight infrared absorption spectroscopy in the wavenumber range of 1276.5-1273.1 cm{sup -1} using a quantum cascade laser spectrometer. Parameters explored include process conditions [pressure, input power, source hydrocarbon, rare gas (Ar or Ne), input gas mixing ratio], height (z) above the substrate, and time (t) after addition of hydrocarbon to a pre-existing Ar/H{sub 2} plasma. The line integrated absorptions so obtained have been converted to species number densities by reference to the companion two-dimensional (r,z) modeling of the CVD reactor described in Mankelevich et al. [J. Appl. Phys. 104, 113304 (2008)]. The gas temperature distribution within the reactor ensures that the measured absorptions are dominated by CH{sub 4} and C{sub 2}H{sub 2} molecules in the cool periphery of the reactor. Nonetheless, the measurements prove to be of enormous value in testing, tensioning, and confirming the model predictions. Under standard process conditions, the study confirms that all hydrocarbon source gases investigated (methane, acetylene, ethane, propyne, propane, and butane) are converted into a mixture dominated by CH{sub 4} and C{sub 2}H{sub 2}. The interconversion between these two species is highly dependent on the local gas temperature and the H atom number density, and thus on position within the reactor. CH{sub 4}->C{sub 2}H{sub 2} conversion occurs most efficiently in an annular shell around the central plasma (characterized by 1400<T{sub gas}<2200 K), while the reverse transformation C{sub 2}H{sub 2}->CH{sub 4} is favored in the more distant regions where T{sub gas}<1400 K. Analysis of the multistep interconversion mechanism reveals substantial net consumption of H atoms accompanying the CH{sub 4}->C{sub 2}H{sub 2} conversion, whereas the reverse C{sub 2}H{sub 2}->CH{sub 4} process only requires H atoms to drive the reactions; H atoms are not consumed by the overall conversion.

36 MATERIALS SCIENCE↗

KM3NeT - The Birth Of A Giant

KM3NeT will be a very large volume (several cubic kilometers) neutrino telescope in the Mediterranean Sea. The up to date status of the project is presented, and the main physics goals are reviewed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reactive sputter magnetron reactor for preparation of thin films and simultaneous in situ structural study by X-ray diffraction

The purpose of the designed reactor is (i) to obtain polycrystalline and/or amorphous thin films by controlled deposition induced by a reactive sputtering magnetron and (ii) to perform a parallel in situ structural study of the deposited thin films by X-ray diffraction, in real time, during the whole growth process. The designed reactor allows for the control and precise variation of the relevant processing parameters, namely, magnetron target-to-sample distance, dc magnetron voltage, and nature of the gas mixture, gas pressure and temperature of the substrate. On the other hand, the chamber can be used in different X-ray diffraction scanning modes, namely, {theta}-2{theta} scanning, fixed {alpha}-2{theta} scanning, and also low angle techniques such as grazing incidence small angle X-ray scattering and X-ray reflectivity. The chamber was mounted on a standard four-circle diffractometer located in a synchrotron beam line and first used for a preliminary X-ray diffraction analysis of AlN thin films during their growth on the surface of a (100) silicon wafer.

36 MATERIALS SCIENCE↗

Fluidized bed coupled rotary reactor for nanoparticles coating via atomic layer deposition

A fluidized bed coupled rotary reactor has been designed for coating on nanoparticles (NPs) via atomic layer deposition. It consists of five major parts: reaction chamber, dosing and fluidizing section, pumping section, rotary manipulator components, as well as a double-layer cartridge for the storage of particles. In the deposition procedure, continuous fluidization of particles enlarges and homogenizes the void fraction in the particle bed, while rotation enhances the gas-solid interactions to stabilize fluidization. The particle cartridge presented here enables both the fluidization and rotation acting on the particle bed, demonstrated by the analysis of pressure drop. Moreover, enlarged interstitials and intense gas–solid contact under sufficient fluidizing velocity and proper rotation speed facilitate the precursor delivery throughout the particle bed and consequently provide a fast coating process. The cartridge can ensure precursors flowing through the particle bed exclusively to achieve high utilization without static exposure operation. By optimizing superficial gas velocities and rotation speeds, minimum pulse time for complete coating has been shortened in experiment, and in situ mass spectrometry showed the precursor usage can reach 90%. Inductively coupled plasma-optical emission spectroscopy results suggested a saturated growth of nanoscale Al{sub 2}O{sub 3} films on spherical SiO{sub 2} NPs. Finally, the uniformity and composition of the shells were characterized by high angle annular dark field-transmission electron microscopy and energy dispersive X-ray spectroscopy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

DETECTION OF INFALLING HYDROGEN IN TRANSFER BETWEEN THE INTERACTING GALAXIES NGC 5426 AND NGC 5427

Using velocity tagging we have detected hydrogen from NGC 5426 falling onto its interacting partner NGC 5427. Our observations, with the GHaFaS Fabry-Perot spectrometer, produced maps of the two galaxies in H{alpha} surface brightness and radial velocity. We found emission with the range of velocities associated with NGC 5426 along lines of sight apparently emanating from NGC 5427, superposed on the velocity map of the latter. After excluding instrumental effects we assign the anomalous emission to gas pulled from NGC 5426 during its passage close to NGC 5427. Its distribution, more intense between the arms and just outside the disk of NGC 5427, and weak, or absent, in the arms, suggests that the infalling gas is behind the disk, ionized by Lyman continuum photons escaping from NGC 5427. Modeling this, we estimate the distances of these gas clouds behind the plane: a few hundred parsecs to a few kiloparsecs. We also estimate the mass of the infalling (ionized plus neutral) gas, finding an infall rate of 10 M{sub sun} per year, consistent with the high measured star formation rate across the disk of NGC 5427 and with the detected circumnuclear galactic wind.

79 ASTRONOMY AND ASTROPHYSICS↗

Liquid sodium testing of in-house phased array EMAT transducer for L-wave applications

This paper describes the development of an in-house phased array EMAT transducer for longitudinal wave inspection in liquid sodium. The work presented herein is part of an undergoing project aimed at improving in-service inspection techniques for the ASTRID reactor project. The design process of the phased array EMAT probe is briefly explained and followed by a review of experimental test results. We first present test results obtained in the laboratory while the last part of the paper describes the liquid sodium testing and the produced ultrasound images. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

AFM Microcantilever With a Collocated AlN Sensor-Actuator Pair: Enabling Efficient Q-Control for Dynamic Imaging

This manuscript presents a novel microcantilever with an embedded piezoelectric sensor-actuator pair for dynamic atomic force microscopy (AFM). The transducer pair is constructed from a two-layered AlN stack. Stacking the piezoelectric transducers in this manner leads to a minimal feedthrough from actuation to sense electrode, granting a high dynamic range frequency response for dynamic mode AFM. The cantilever's design allows for dual mode operation at 1 st and 2 nd resonance modes. High resolution tapping mode imaging results are reported, while the cantilever is operated at these modes. A feedback control loop is used to modify quality factor of the 1 st mode of the cantilever, using a positive position feedback (PPF) controller. Here, a faster response time is achieved by reducing the Q-factor, enabling the cantilever to track the topography at a higher scan rate. Results of bimodal AFM imaging are reported, using amplitude changes of the 1 st mode for surface topography, while material properties are encoded in phase changes of the 2 nd mode.

47 OTHER INSTRUMENTATION↗

Development of a pixelated GSO gamma camera system with tungsten parallel hole collimator for single photon imaging

Purpose: In small animal imaging using a single photon emitting radionuclide, a high resolution gamma camera is required. Recently, position sensitive photomultiplier tubes (PSPMTs) with high quantum efficiency have been developed. By combining these with nonhygroscopic scintillators with a relatively low light output, a high resolution gamma camera can become useful for low energy gamma photons. Therefore, the authors developed a gamma camera by combining a pixelated Ce-doped Gd{sub 2}SiO{sub 5} (GSO) block with a high quantum efficiency PSPMT. Methods: GSO was selected for the scintillator, because it is not hygroscopic and does not contain any natural radioactivity. An array of 1.9 mm x 1.9 mm x 7 mm individual GSO crystal elements was constructed. These GSOs were combined with a 0.1-mm thick reflector to form a 22 x 22 matrix and optically coupled to a high quantum efficiency PSPMT (H8500C-100 MOD8). The GSO gamma camera was encased in a tungsten gamma-ray shield with tungsten pixelated parallel hole collimator, and the basic performance was measured for Co-57 gamma photons (122 keV). Results: In a two-dimensional position histogram, all pixels were clearly resolved. The energy resolution was {approx}15% FWHM. With the 20-mm thick tungsten pixelated collimator, the spatial resolution was 4.4-mm FWHM 40 mm from the collimator surface, and the sensitivity was {approx}0.05%. Phantom and small animal images were successfully obtained with our developed gamma camera. Conclusions: These results confirmed that the developed pixelated GSO gamma camera has potential as an effective instrument for low energy gamma photon imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Smoothing tool design and performance during subaperture glass polishing

During subaperture tool grinding and polishing, overlaps of the tool influence function can result in undesirable mid-spatial frequency (MSF) errors in the form of surface ripples, which are often corrected using a smoothing polishing step. Here, in this study, flat multi-layer smoothing polishing tools are designed and tested to simultaneously (1) reduce or remove MSF errors, (2) minimize surface figure degradation, and (3) maximize the material removal rate. A time-dependent convergence model in which spatial material removal varies with a workpiece-tool height mismatch, combined with a finite element mechanical analysis to determine the interface contact pressure distribution, was developed to evaluate various smoothing tool designs as a function of tool material properties, thicknesses, pad textures, and displacements. An improvement in smoothing tool performance is achieved when the gap pressure constant, $\overline{h}$ (which describes the inverse rate at which the pressure drops with a workpiece-tool height mismatch), is minimized for smaller spatial scale length surface features (namely, MSF errors) and maximized for large spatial scale length features (i.e., surface figure). Five specific smoothing tool designs were experimentally evaluated. A two-layer smoothing tool using a thin, grooved IC1000 polyurethane pad (with a high elastic modulus, E pad =360 MPa ), thicker blue foam (with an intermediate modulus, E foam =5.3 MPa ) underlayer, and an optimized displacement (d t =1 mm ) provided the best overall performance (namely, high MSF error convergence, minimal surface figure degradation, and high material removal rate).

47 OTHER INSTRUMENTATION↗

Improved Ion Resistance for III-V Photocathodes in High Current Guns

The two photocathode test systems were modified, baked and recommissioned. The first system was dedicated to ion studies and the second to electron stimulated recovery (ESR) work. The demonstration system for the electron beam rejuvenation was set up, tested and demonstrated to one of the SSRL team (Dr. Kirby) during a site visit. The requisite subsystems were transferred to SSRL, installed and photoemission studies conducted on activated surfaces following electron beam exposure. Little surface chemistry change was detected in the photoemission spectra following the ESR process. The yield mapping system for the ion (and later, the electron beam rejuvenation) studies was implemented and use made routine. Ion species and flux measurements were performed for H, He, Ne, Ar, Kr and Xe ions at energies of 0.5, 1.0 and 2.0 kV. Gas induced photoyield measurements followed each ion exposure measurement. These data permit the extraction of photoyield induced change per ion (by species) at the measured energies. Electron beam induced rejuvenation was first demonstrated in the second chamber with primary electron beam energy and dependency investigations following. A Hiden quadrupole mass spectrometer for the electron stimulated desorption (ESD) measurements was procured. The UHV test systems needed for subsequent measurements were configured, baked, commissioned and utilized for their intended purposes. Measurements characterizing the desorption products from the ESD process and secondary electron (SE) yield at the surfaces of negative electron affinity GaAs photocathodes have been performed. One US Utility Patent was granted covering the ESR process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗