Search NASA⌕ Search

SEARCH · Search NASA

Results for “total variation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

HERSCHEL EXPLOITATION OF LOCAL GALAXY ANDROMEDA (HELGA). III. THE STAR FORMATION LAW IN M31

We present a detailed study of how the star formation rate (SFR) relates to the interstellar medium (ISM) of M31 at {approx}140 pc scales. The SFR is calculated using the far-ultraviolet and 24 {mu}m emission, corrected for the old stellar population in M31. We find a global value for the SFR of 0.25{sup +0.06}{sub -0.04} M{sub sun} yr{sup -1} and compare this with the SFR found using the total far-infrared luminosity. There is general agreement in regions where young stars dominate the dust heating. Atomic hydrogen (H I) and molecular gas (traced by carbon monoxide, CO) or the dust mass is used to trace the total gas in the ISM. We show that the global surface densities of SFR and gas mass place M31 among a set of low-SFR galaxies in the plot of Kennicutt. The relationship between SFR and gas surface density is tested in six radial annuli across M31, assuming a power law relationship with index, N. The star formation (SF) law using total gas traced by H I and CO gives a global index of N = 2.03 {+-} 0.04, with a significant variation with radius; the highest values are observed in the 10 kpc ring. We suggest that this slope is due to H I turning molecular at {Sigma}{sub Gas} {approx} 10 M{sub Sun} pc{sup -2}. When looking at H{sub 2} regions, we measure a higher mean SFR suggesting a better spatial correlation between H{sub 2} and SF. We find N {approx} 0.6 with consistent results throughout the disk-this is at the low end of values found in previous work and argues against a superlinear SF law on small scales.

79 ASTRONOMY AND ASTROPHYSICS↗

Velocity-resolved [C ii] emission and [C ii]/FIR mapping along Orion with Herschel

We present the first ∼7.′5 × 11.′5 velocity-resolved (∼0.2 km s{sup −1}) map of the [C ii] 158 μm line toward the Orion molecular cloud 1 (OMC 1) taken with the Herschel/HIFI instrument. In combination with far-IR (FIR) photometric images and velocity-resolved maps of the H41α hydrogen recombination and CO J = 2–1 lines, this data set provides an unprecedented view of the intricate small-scale kinematics of the ionized/photodissociation region (PDR)/molecular gas interfaces and of the radiative feedback from massive stars. The main contribution to the [C ii] luminosity (∼85%) is from the extended, FUV-illuminated face of the cloud (G{sub 0} > 500, n{sub H} > 5 × 10{sup 3} cm{sup −3}) and from dense PDRs (G{sub 0} ≳ 10{sup 4}, n{sub H} ≳ 10{sup 5} cm{sup −3}) at the interface between OMC 1 and the H ii region surrounding the Trapezium cluster. Around ∼15% of the [C ii] emission arises from a different gas component without a CO counterpart. The [C ii] excitation, PDR gas turbulence, line opacity (from [{sup 13}C ii]), and role of the geometry of the illuminating stars with respect to the cloud are investigated. We construct maps of the L[C ii]/L{sub FIR} and L{sub FIR}/M{sub Gas} ratios and show that L[C ii]/L{sub FIR} decreases from the extended cloud component (∼10{sup −2}–10{sup −3}) to the more opaque star-forming cores (∼10{sup −3}−10{sup −4}). The lowest values are reminiscent of the “[C ii] deficit” seen in local ultraluminous IR galaxies hosting vigorous star formation. Spatial correlation analysis shows that the decreasing L[C ii]/L{sub FIR} ratio correlates better with the column density of dust through the molecular cloud than with L{sub FIR}/M{sub Gas}. We conclude that the [C ii]-emitting column relative to the total dust column along each line of sight is responsible for the observed L[C ii]/L{sub FIR} variations through the cloud.

79 ASTRONOMY AND ASTROPHYSICS↗

Direct and semi-direct capture in low-energy (n,{gamma}) reactions of neutron-rich tin isotopes and its implications for r-process nucleosynthesis

The direct and semi-direct (DSD) components of the neutron capture cross sections are calculated for a series of tin isotopes by employing a single-particle potential (SPP) that gives a good reproduction of the known single-particle energies (SPEs) over a wide mass region. The results are compared with the Hauser-Feshbach (HF) contribution in the energy region of astrophysical interest. The calculated result shows that the HF component drops off rapidly for isotope {sup 132}Sn and toward more neutron-rich ones, whereas the DSD component decreases only smoothly and eventually becomes dominant. This result is consistent with those of previous studies, but the dependence of the DSD cross section on the target mass number is a feature of the present SPP that gives a smooth variation of SPEs. As a consequence, the direct portion of the DSD component gives the largest contribution to the total (n,{gamma}) cross section for neutron-rich isotopes below a few MeV. Therefore, the direct capture process modifies the astrophysical (n,{gamma}) reaction rates to a great extent. The semi-direct component, however, gives a negligible contribution to the astrophysical reaction rates, but its impact is significant above several MeV. The reason for the difference in isotopic dependence between the HF and DSD components is discussed, and its implication for r-process nucleosynthesis is given.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A 4 kV/120 A SiC Solid-State DC Circuit Breaker Powered By a Load-Independent IPT System

This article introduces a 4 kV/120 A solid-state dc circuit breaker (DCCB) based on discrete SiC mosfets. The DCCB is designed in a five-layer tower structure. Each layer consists of a circular main conduction branch and an attached gate driver. There are two primary benefits of the proposed DCCB. First, it reduces conduction loss with multiple devices in parallel. Second, it achieves an ultrafast response speed with SiC mosfets. Moreover, the gate drivers of the DCCB are powered by a domino inductive power transfer (IPT) system. It achieves the load-independent constant-voltage output characteristics, which means the outputs are immune to load variations. Additionally, an IPT system prototype is implemented to test the power transfer performance. At 500-kHz frequency, the total output power reaches 15.73 W, which is sufficient to power on five gate drivers, with a peak transfer efficiency of 75.4%. The IPT system is tested to power a 4 kV/120 A DCCB prototype. It validates that the DCCB is effective to turn off 120 A current within 3.5 μs.

42 ENGINEERING↗

High-efficiency, large-aperture fifth-harmonic: Generation of 211-nm pulses in ammonium dihydrogen phosphate crystals for fusion diagnostics

High-energy ultraviolet (UV) sources are required to probe hot dense plasmas from fusion experiments by using Thomson scattering resulting from the lower self-generated background from the plasma in the 180 to 230-nm spectral region. Although recently we demonstrated efficient, joule-class fifth harmonic conversion of 1053-nm pulses using a cesium lithium borate (CLBO) crystal, larger crystals are necessary for increased UV energy. This paper presents an alternative approach for fifth-harmonic generation of a large-aperture neodymium laser using ammonium dihydrogen phosphate (ADP). An Nd:YLF laser was optimized to produce square pulses with a flattop, square beam profile (1053 nm, 1 to 2.8 ns, 12 x 12 mm, ≤1.5 J, ≤5 Hz). Noncritical phase matching in ADP suitable for sum–frequency mixing the fourth harmonic with residual fundamental light was achieved by cooling the crystal (65 x 65 x 10 mm) in a two-chamber cryostat to 200 K. The crystal chamber used helium (1 atm) as the thermally conductive medium between the crystal and the crystal chamber, which in turn was surrounded by a high-vacuum chamber that contained a liquid nitrogen reservoir to cool the crystal chamber. Temperature variation of 0.4 K across the crystal aperture was obtained using two 50-W heaters with active feedback. The total conversion efficiency from the fundamental to the fifth harmonic, including surface losses and absorption, was 26%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MO-G-17A-06: Kernel Based Dosimetry for 90Y Microsphere Liver Therapy Using 90Y Bremsstrahlung SPECT/CT

Purpose: 90Y microsphere therapy in liver presents a situation where beta transport is dominant and the tissue is relatively homogenous. We compare voxel-based absorbed doses from a 90Y kernel to Monte Carlo (MC) using quantitative 90Y bremsstrahlung SPECT/CT as source distribution. Methods: Liver, normal liver, and tumors were delineated by an interventional radiologist using contrast-enhanced CT registered with 90Y SPECT/CT scans for 14 therapies. Right lung was segmented via region growing. The kernel was generated with 1.04 g/cc soft tissue for 4.8 mm voxel matching the SPECT. MC simulation materials included air, lung, soft tissue, and bone with varying densities. We report percent difference between kernel and MC (%Δ(K,MC)) for mean absorbed dose, D70, and V20Gy in total liver, normal liver, tumors, and right lung. We also report %Δ(K,MC) for heterogeneity metrics: coefficient of variation (COV) and D10/D90. The impact of spatial resolution (0, 10, 20 mm FWHM) and lung shunt fraction (LSF) (1,5,10,20%) on the accuracy of MC and kernel doses near the liver-lung interface was modeled in 1D. We report the distance from the interface where errors become <10% of unblurred MC as d10(side of interface, dose calculation, FWHM blurring, LSF). Results: The %Δ(K,MC) for mean, D70, and V20Gy in tumor and liver was <7% while right lung differences varied from 60–90%. The %Δ(K,MC) for COV was <4.8% for tumor and liver and <54% for the right lung. The %Δ(K,MC) for D10/D90 was <5% for 22/23 tumors. d10(liver,MC,10,1–20) awere <9mm and d10(liver,MC,20,1–20) awere <15mm; both agreed within 3mm to the kernel. d10(lung,MC,10,20), d10(lung,MC,10,1), d10(lung,MC,20,20), and d10(lung,MC,20,1) awere 6, 25, 15, and 34mm, respectively. Kernel calculations on blurred distributions in lung had errors > 10%. Conclusions: Liver and tumor voxel doses with 90Y kernel and MC agree within 7%. Large differences exist between the two methods in right lung. Research reported in this publication was supported by the National Cancer Institute of the National Institutes of Health under Award Number R01CA138986. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.

60 APPLIED LIFE SCIENCES↗

SU-E-T-315: Dosimetric Effects of Couch Top Shift On VMAT Delivery in Absence of Indexing

Purpose: To investigate dosimetric effects of couch top shift for volumetric-modulated arc therapy (VMAT) in absence of indexing of immobilization devices. Methods: A total of twelve VMAT treatment plans were selected from three regions (lung, abdomen, and pelvis) to account for the variation of the patient position relative to the couch top. The treatment plans were generated using the Varian Eclipse system. A pinpoint ionization chamber (PTW TN31014) was placed at the center of 16-cm solid water phantom and the dose was delivered using the Varian TrueBeam STx with BrainLAB ExacTrac couch top. To simulate the day-to-day variation of the patient position relative to couch top, the couch top was laterally shifted up to 50 mm, with an increment of 5 mm from 0 to 20 mm; and of 10 mm afterwards, and the phantom was moved back to 0 cm shift for measurement. The dose was also delivered using a Varian tennis racket grid insert at 0 cm shift to simulate the absence of couch top. The treatment plans were delivered with 6, 10, and 15 MV photons using the same leaf sequencing to investigate the energy dependence of couch top shift. The dose difference was normalized to 0 cm shift for the regular couch top for comparison. Results: The percent difference of dose was found to increase with lateral shift for all energies; however, the average differences were close to 0% and the maximum difference was within 1% along the lateral shifts. The differences with the absence of couch top were 2.2±0.5% (6MV), 1.7±0.3% (10MV), and 1.6±0.2% (15MV), respectively. Conclusion: The inclusion of couch top is recommended in treatment planning to minimize the dosimetric uncertainty between calculated and delivered dose even in absence of indexing of immobilization devices in VMAT delivery.

60 APPLIED LIFE SCIENCES↗

Features of the Characteristics of Field-Resistant Silicon–Ultrathin Oxide–Polysilicon Structures

Results of studying the features of the current–voltage (I–V) and capacitance–voltage characteristics of field-resistant silicon–ultrathin oxide–polysilicon structures are presented. It turns out that the total recharging of localized electron states and minority carriers concentrated near the substrate–insulator interface, which occurs with a variation in the field voltage, is an order of magnitude higher than that of samples susceptible to damage by the field stress effect. The tunneling I–V characteristic is significantly asymmetric; notably, the current flowing from the field electrode into the silicon substrate is several orders of magnitude lower when compared with the current flowing from silicon to polysilicon at identical external voltages dropping across the insulating layer. To explain this asymmetry, it is assumed that a potential barrier in the transition layer from polysilicon to oxide, which separates the semiconductor electrode and substrate, has a height of ~1 eV and therefore always hinders electrical transport; for reverse currents, this barrier stops limiting the conductivity as soon as the tunneling level becomes higher than it.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Syracuse Univesity Test Report On Uptake Factor Resulting From A Dropped Storage Container - Phase II

Under certain circumstances, powder from an accidently dropped container can become airborne and inhaled by people nearby such as those who are moving the containers. The inhaled fine particles can deposit on respiratory tracts and lungs, causing asthma, lung cancer, and other acute respiratory illnesses and chronic symptoms. The objective of this study was to develop a standard procedure to measure the airborne concentrations of different size particles within the vicinity of a dropped container where a significant portion of the contained powder is ejected. Tungsten oxide (WO 3 ) was selected in this study to represent relatively heavy powders (7.16 g/cm 3 specific gravity for WO 3 ). A typical can with the outer dimensions of 4.25” diameter and 4.875” tall was used as the container. The powder was dropped in two different configurations: 1) contained within a can covered by a lid that has a 0.25” diameter hole, and 2) contained within a can without a lid. The packing volume of the powder was 51.4 in 3 (842.7 cm 3 ) and the target mass was 1936 g. The tests were carried out in a full-scale stainless steel environmental chamber with an interior volume of 852 ft 3 (24.1 m3). The chamber system includes an internal recirculation loop with a rectangular air diffuser and 10 variable frequency drive fans to provide a typical room air recirculation flow pattern. Two air filters were installed in the chamber air supply duct and return duct to achieve the required low background particle concentration. The initial chamber air conditions were set at 70°F (± 5°F) and 50% (± 10%) RH. A supporting frame and releasing device were designed and built to trigger consistently the dropping of the can. The particle sampling inlet was placed 5 ft above the floor and 6 inches laterally away from the can’s falling path. Concentrations of particles between 0.5 μm and 20 μm were recorded in units of mass and number of particles per unit volume. The data acquisition rate was once every 2 seconds during the first 2 hours. A test procedure was developed and verified. A total of thirty two drop tests were performed, eight in Phase I and twenty four in Phase II, covering variations in dropping height (8 ft or 4 ft from the floor), room air movement (0.25-0.30 m/s or 0.10-0.15 m/s near the ceiling), landing scenario (on a flat plate or a block), and lid condition (¼” lid hole or no lid). There were ten tests with flat plate and ¼” lid hole, ten tests with flat plate no lid and twelve tests with block no lid.

42 ENGINEERING↗

Continuous liquid level measurements with time domain reflectometry

A time domain reflectometer is considered as a closed loop, one-dimensional radar system. Applying the principle of time domain reflectometry to the detection of cryogenic liquid levels, measurements on the order of + or - 0. 3% of total liquid level probe length are possible. The time domain reflectometer liquid level measurement is independent of liquid density variations and is simple to calibrate and operate. Construction of the liquid level sensing probe is described.

Cruz, J. E.↗

Recent improvements in our knowledge of neutral atmosphere structure from satellite drag measurements

Observational results on the density in the thermosphere and lower exosphere (i.e., within the altitude range from about 150 to about 1000 km) are discussed in this paper. Most observational results on total gas density were obtained from orbital drag and more recently also from in-situ drag analysis. The primary parameter measured is atmospheric density, with temperature as a secondary structural parameter deduced with the help of theory and/or atmospheric models. Both the merits and shortcomings of the drag analysis method are outlined in view of a comparison of temperature deduced from total density and kinetic gas temperature measured by incoherent scatter. Recent improvements of our knowledge of the known density variations are presented.

Roemer, M.↗

Investigation of transient earth resources phenomena: Continuation study

Calculated sensitivity requirements for an earth resource satellite in a geostationary orbit are reported. Radiance levels at the satellite sensor were computed for twenty top-priority Synchronous Earth Observatory Satellite (SEOS) applications. The observation requirements were reviewed and re-evaluated in terms of spectral band definition, spectral signatures of targets and backgrounds, observation time, and site location. With these data and an atmospheric attenuation and scattering model, the total radiances observed by the SEOS sensor were calculated as were the individual components contributed by the target, target variations, and the atmosphere.

Goldman, G. C.↗

Some anomalies observed in wind-tunnel tests of a blunt body at transonic and supersonic speeds

An investigation of anomalies observed in wind tunnel force tests of a blunt body configuration was conducted at Mach numbers from 0.20 to 1.35 in the Langley 8-foot transonic pressure tunnel and at Mach numbers of 1.50, 1,80, and 2.16 in the Langley Unitary Plan wind tunnel. At a Mach number of 1.35, large variations occurred in axial force coefficient at a given angle of attack. At transonic and low supersonic speeds, the total drag measured in the wind tunnel was much lower than that measured during earlier ballistic range tests. Accurate measurements of total drag for blunt bodies will require the use of models smaller than those tested thus far; however, it appears that accurate forebody drag results can be obtained by using relatively large models. Shock standoff distance is presented from experimental data over the Mach number range from 1.05 to 4.34. Theory accurately predicts the shock standoff distance at Mach numbers up to 1.75.

Brooks, J. D.↗

Semi-empirical calculation of depletion region width in n+-p silicon solar cells

An extension of the width calculation for impurity distributions of complementary error function and the Gaussian function, in addition to the exponential function is used in combination with experimental width values deduced from capacitance measurements at zero bias to numerically determine the width occurring in both the n+ and p junctions. The total possible error o the semi-empirical calculation is less than plus or minus 3%. Results show considerable variation in the depletion widths occurring in the n+ and p regions for different impurity profiles.

Wang, E. Y.↗

Rare earth and trace element geochemistry of a fragment of Jurassic seafloor, Point Sal, California

Rocks from an ophiolite suite once on the seafloor were analyzed for rare earth elements (REE), Sc, Co, Na2O, Cr, Zn and FeO. Strontium isotope exchange noted in some of the lavas is attributed to basalt-seawater interaction; the Ce abundance in smectite- and zeolite-bearing lavas may also be due to prolonged exposure to seawater. The higher grades of metamorphic rock, however, show no variation from the usual flat or slightly light REE depleted profiles. Plutonic igneous rock, all light REE depleted, have total REE abundances varying by a factor of 100 between the dunites and diorites. In order of decreasing REE abundance are hornblende, clinopyroxene, plagioclase, orthopyroxene and olivine. Calculations of REE contents of liquids in equilibrium with early cumulative clinopyroxenes suggest that the parent to the stratiform sequence was more depleted in light REE than the parent to the lava pile.

Menzies, M.↗

The sensitivity of the general circulation to Arctic Sea ice boundaries - A numerical experiment

Results are presented for a set of numerical experiments conducted with the Goddard (formerly GISS) general circulation model. The experiments were designed to test the model atmospheric response to a single fixed and specified parameter, the total ice cover in the Davis Strait, Barents Sea, East Greenland Sea, Sea of Okhotsk and Bering Sea. Margin variations are considered that are substantially smaller than those involved in ice age or ice-free Arctic simulations. Anomaly is defined as the mean of two runs corresponding to climatological maximum sea ice conditions. Model results indicate that the ice margin anomalies are capable of altering local climates in certain regions of high and middle latitudes. Possible interactions between high latitudes and subtropical regions are suggested.

Herman, G. F.↗

Analysis of space systems for the space disposal of nuclear waste follow-on study. Volume 2: Technical report

The space option for disposal of certain high-level nuclear wastes in space as a complement to mined geological repositories is studied. A brief overview of the study background, scope, objective, guidelines and assumptions, and contents is presented. The determination of the effects of variations in the waste mix on the space systems concept to allow determination of the space systems effect on total system risk benefits when used as a complement to the DOE reference mined geological repository is studied. The waste payload system, launch site, launch system, and orbit transfer system are all addressed. Rescue mission requirements are studied. The characteristics of waste forms suitable for space disposal are identified. Trajectories and performance requirements are discussed.

Source record↗

Velocity gradient method for calulating velocities in an axisymmetric annular duct

The velocity distribution along an arbitrary line between the inner and outer walls of an annular duct with axisymmetric swirling flow is calculated. The velocity gradient equation is used with an assumed variation of meridional streamline curvature. Upstream flow conditions can vary between the inner and outer walls, and an assumed total pressure distribution can be specified.

Katsanis, T.↗