Search NASA⌕ Search

SEARCH · Search NASA

Results for “variational optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Improving reproducibility in synchrotron tomography using implementation-adapted filters

For reconstructing large tomographic datasets fast, filtered backprojection-type or Fourier-based algorithms are still the method of choice, as they have been for decades. These robust and computationally efficient algorithms have been integrated in a broad range of software packages. The continuous mathematical formulas used for image reconstruction in such algorithms are unambiguous. However, variations in discretization and interpolation result in quantitative differences between reconstructed images, and corresponding segmentations, obtained from different software. This hinders reproducibility of experimental results, making it difficult to ensure that results and conclusions from experiments can be reproduced at different facilities or using different software. In this paper, a way to reduce such differences by optimizing the filter used in analytical algorithms is proposed. These filters can be computed using a wrapper routine around a black-box implementation of a reconstruction algorithm, and lead to quantitatively similar reconstructions. Use cases for this approach are demonstrated by computing implementation-adapted filters for several open-source implementations and applying them to simulated phantoms and real-world data acquired at the synchrotron. Our contribution to a reproducible reconstruction step forms a building block towards a fully reproducible synchrotron tomography data processing pipeline.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-T-107: Development of a GPU-Based Dose Delivery System for Adaptive Pencil Beam Scanning

Purpose: A description of a GPU-based dose delivery system (G-DDS) to integrate a fast forward planning implementing in real-time the prescribed sequence of pencil beams. The system, which is under development, is designed to evaluate the dose distribution deviations due to range variations and interplay effects affecting mobile tumors treatments. Methods: The Dose Delivery System (DDS) in use at the Italian Centro Nazionale di Adroterapia Oncologica (CNAO), is the starting point for the presented system. A fast and partial forward planning (FP) tool has been developed to evaluate in few seconds the delivered dose distributions using the DDS data (on-line measurements of spot properties, i.e. number of particles and positions). The computation is performed during the intervals between synchrotron spills and, made available at the end of each spill. In the interval between two spills, the G-DDS will evaluate the delivered dose distributions taking into account the real-time target positions measured by a tracking system. The sequence of prescribed pencil beams for the following spill will be adapted taking into account the variations with respect to the original plan due to the target motion. In order to speed up the computation required to modify pencil beams distribution (up to 400 times has been reached), the Graphics Processing Units (GPUs) and advanced Field Programmable Gate Arrays (FPGAs) are used. Results: An existing offline forward planning is going to be optimized for the CUDA architecture: the gain in time will be presented. The preliminary performances of the developed GPU-based FP algorithms will be shown. Conclusion: A prototype of a GPU-based dose delivery system is under development and will be presented. The system workflow will be illustrated together with the approach adopted to integrate the three main systems, i.e. CNAO dose delivery system, fast forward planning, and tumor tracking system.

60 APPLIED LIFE SCIENCES↗

TU-G-BRD-08: In-Vivo EPID Dosimetry: Quantifying the Detectability of Four Classes of Errors

Purpose: EPID dosimetry is an emerging method for treatment verification and QA. Given that the in-vivo EPID technique is in clinical use at some centers, we investigate the sensitivity and specificity for detecting different classes of errors. We assess the impact of these errors using dose volume histogram endpoints. Though data exist for EPID dosimetry performed pre-treatment, this is the first study quantifying its effectiveness when used during patient treatment (in-vivo). Methods: We analyzed 17 patients; EPID images of the exit dose were acquired and used to reconstruct the planar dose at isocenter. This dose was compared to the TPS dose using a 3%/3mm gamma criteria. To simulate errors, modifications were made to treatment plans using four possible classes of error: 1) patient misalignment, 2) changes in patient body habitus, 3) machine output changes and 4) MLC misalignments. Each error was applied with varying magnitudes. To assess the detectability of the error, the area under a ROC curve (AUC) was analyzed. The AUC was compared to changes in D99 of the PTV introduced by the simulated error. Results: For systematic changes in the MLC leaves, changes in the machine output and patient habitus, the AUC varied from 0.78–0.97 scaling with the magnitude of the error. The optimal gamma threshold as determined by the ROC curve varied between 84–92%. There was little diagnostic power in detecting random MLC leaf errors and patient shifts (AUC 0.52–0.74). Some errors with weak detectability had large changes in D99. Conclusion: These data demonstrate the ability of EPID-based in-vivo dosimetry in detecting variations in patient habitus and errors related to machine parameters such as systematic MLC misalignments and machine output changes. There was no correlation found between the detectability of the error using the gamma pass rate, ROC analysis and the impact on the dose volume histogram. Funded by grant R18HS022244 from AHRQ.

60 APPLIED LIFE SCIENCES↗

SU-F-T-194: Analyzing the Effect of Range Shifter Air Gap On TPS Dose Modeling Accuracy in Superficial PBS Proton Therapy

Purpose: Treatment planning systems (TPS) may not accurately model superficial dose distributions of range shifted proton pencil beam scanning (PBS) treatments. Numerous patient-specific QA tests performed on superficially treated PBS plans have shown a consistent overestimate of dose by the TPS. This study quantifies variations between TPS planned dose and measured dose as a function of range shifter air gap and treatment depths up to 5 cm. Methods: PBS treatment plans were created in the TPS to uniformly irradiate a volume of solid water. One plan was created for each range shifter position analyzed, and all plans utilized identical dose optimization parameters. Each optimized plan was analyzed in the TPS to determine the planned dose at varying depths. A PBS proton therapy system with a 3.5 cm lucite range shifter delivered the treatment plans, and a parallel plate chamber embedded in RW3 solid water measured dose at shallow depths for each air gap. Differences between measured and planned doses were plotted and analyzed. Results: The data show that the TPS more accurately models superficial dose as the air gap between the range shifter and patient surface decreases. Air gaps less than 10 cm have an average dose difference of only 1.6%, whereas air gaps between 10 and 20 cm differ by 3.0% and gaps greater than 20 cm differ by 4.4%. Conclusion: This study has shown that the TPS is unable to accurately model superficial dose with a large range shifter air gap. Dose differences greater than 3% will likely cause QA failure, as many institutions analyze patient QA with a 3%/3mm gamma analysis. For superficial PBS therapy, range shifter positions should be chosen to keep the air gap less then 10 cm when patient setup and gantry geometry allow.

60 APPLIED LIFE SCIENCES↗

Relating Quantitative Soil Structure Metrics to Saturated Hydraulic Conductivity

Core Ideas Soil structure quantified in the field using a 3D laser scanning technique (MLT). MLT data and coefficient of linear extensibility combined into a structure metric. Soil water contents recorded at four depths in a field lysimeter and used in HYDRUS‐1D. Saturated conductivity ( K s ) estimated with a Markov chain Monte Carlo approach. New metric better correlated to K s in horizons with strong soil structure. Soil structure affects saturated hydraulic conductivity ( K s ) by creating highly conductive macropores that preferentially transmit soil water. In this study, we explored the relationship between K s and macropores in an Oxyaquic Vertic Argiudoll in northeastern Kansas. Macropores were quantified from an excavation wall using multistripe laser triangulation (MLT) scanning. Soil water contents were measured at four depths within a soil lysimeter installed within 2 m of the MLT‐scanned soil profile and adjacent to an Ameriflux tower monitoring precipitation, air temperature, and solar radiation. Selected hydraulic properties of soil horizons within the lysimeter were optimized to water content data using a Markov chain Monte Carlo technique in combination with the mobile–immobile water (MIM) model in HYDRUS‐1D. Estimates of K s varied between 4198 cm d −1 in the A horizon and 0.6 cm d −1 in a 2Btss2 horizon with strongly expressed wedge structure. Approximately 87% of the variation in K s was explained by the geometric mean of the widths of pores quantified with the MLT technique and modified by the coefficient of linear extensibility (COLE). The use of the COLE allows the widths of the macropores obtained under dry conditions to be approximated at saturation. Two models that predict K s from either texture or water retention data resulted in K s estimates that were similar to each other but significantly lower than K s values predicted with MIM in horizons where structural pores dominate water flow. This technique shows a great deal of promise in better understanding and predicting the relationship of soil structure to water flow.

Eck, Dennis V.↗

Characterization of Build Parameters and Microstructure in Low Heat Input WAAM of Ni-Based Superalloy Haynes 282

Ni-based superalloy Haynes® 282® is being targeted for various applications in advanced power generation systems for its superior fabricability, weldability, and excellent high temperature creep and corrosion performance. This process optimization study aims to use a low heat-input, high deposition rate, controlled Gas Metal Arc Welding (GMAW) process, Cold Metal Transfer (CMT) by Fronius, attempting to achieve fully dense fabrication and possibly avoid the need for HIP. Twenty-one multilayer blocks (~25x100x40 mm3) were deposited to explore a large set of build parameters variations that focused on varying the travel speed from 14 to 42 inches per minute (ipm) and wire feed speed from 150 to 450 ipm. A strong correlation has been observed between arc energy – controlled primarily by travel and wire feed speed. Initial visual inspection, internal microstructural examination, and computed tomography (CT) have been used to determine the effects of built parameters on evolution of internal porosity and defects. Scanning electron microscopy techniques enabled structural and compositional imaging of heterogeneity and changes in microstructural properties.

additive manufacturing↗

Harnessing Ocean Thermal Gradients Using Thermoelectric Based Submersibles for Ocean Power Applications

The urgent need for energy solutions in marine environments has accelerated the development of innovative technologies capable of leveraging natural resources for power generation. This study introduces a buoyancy-driven submersible system designed to harness ocean thermal gradients using thermoelectric generators (TEGs) and phase change materials (PCMs). The technology aims to provide autonomous power to offshore aquaculture farms, unmanned underwater vehicles (UUVs), offshore platform illumination, and ocean sensors, significantly reducing dependence on fossil fuels. Ocean thermal gradients, especially prevalent in mid-latitude regions, exhibit temperature differences between surface and deep waters ranging from 7 degrees Celsius to 30 degrees Celsius depending on seasonal variations. The proposed submersible technology utilizes TEGs to convert thermal energy from these gradients into electrical power, generating between 0.2 and 0.5 watts, while PCMs are employed to store and regulate this energy, ensuring a stable and continuous power supply. The buoyancy-driven mechanism of the submersible enhances its capability to navigate through varying depths, optimizing its exposure to different thermal gradients and maximizing energy harvesting. The performance of this submersible system is analyzed through detailed thermodynamic assessments and computational fluid dynamics (CFD) modeling focused on heat transfer. These analyzes consider real-world ocean temperature profiles and seek to refine the interaction between TEGs and PCMs to optimize energy extraction. The evaluation encompasses several key performance metrics, including power output and energy efficiency. Results confirm the potential of this innovative technology to provide a continuous and reliable power source for marine applications. By demonstrating the feasibility of using ocean thermal gradients for energy generation, this study contributes to the broader efforts of innovation in energy technologies for harsh, remote marine environments. The implementation of such promises is significant advancements in the autonomy of marine operations. The ongoing research will further investigate scalability ensuring that the system can be effectively adapted to various marine settings and operational demands.

16 TIDAL AND WAVE POWER↗

Study of beam transverse properties of a thermionic electron gun for application to a compact THz free electron laser

A novel thermionic electron gun adopted for use in a high power THz free electron laser (FEL) is proposed in this paper. By optimization of the structural and radiofrequency (RF) parameters, the physical design of the gun is performed using dynamic calculations. Velocity bunching is used to minimize the bunch's energy spread, and the dynamic calculation results indicate that high quality beams can be provided. The transverse properties of the beams generated by the gun are also analyzed. The novel RF focusing effects of the resonance cavity are investigated precisely and are used to establish emittance compensation, which enables the injector length to be reduced. In addition, the causes of the extrema of the beam radius and the normalized transverse emittance are analyzed and interpreted, respectively, and slice simulations are performed to illustrate how the RF focusing varies along the bunch length and to determine the effects of that variation on the emittance compensation. Finally, by observation of the variations of the beam properties in the drift tube behind the electron gun, prospective assembly scenarios for the complete THz-FEL injector are discussed, and a joint-debugging process for the injector is implemented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Material and energy recovery in integrated waste management systems: Project overview and main results

Highlights: > The source separation level (SSL) of waste management system does not qualify adequately the system. > Separately collecting organic waste gives less advantages than packaging materials. > Recycling packaging materials (metals, glass, plastics, paper) is always attractive. > Composting and anaerobic digestion of organic waste gives questionable outcomes. > The critical threshold of optimal recycling seems to be a SSL of 50%. - Abstract: This paper describes the context, the basic assumptions and the main findings of a joint research project aimed at identifying the optimal breakdown between material recovery and energy recovery from municipal solid waste (MSW) in the framework of integrated waste management systems (IWMS). The project was carried out from 2007 to 2009 by five research groups at Politecnico di Milano, the Universities of Bologna and Trento, and the Bocconi University (Milan), with funding from the Italian Ministry of Education, University and Research (MIUR). Since the optimization of IWMSs by analytical methods is practically impossible, the search for the most attractive strategy was carried out by comparing a number of relevant recovery paths from the point of view of mass and energy flows, technological features, environmental impact and economics. The main focus has been on mature processes applicable to MSW in Italy and Europe. Results show that, contrary to a rather widespread opinion, increasing the source separation level (SSL) has a very marginal effects on energy efficiency. What does generate very significant variations in energy efficiency is scale, i.e. the size of the waste-to-energy (WTE) plant. The mere value of SSL is inadequate to qualify the recovery system. The energy and environmental outcome of recovery depends not only on 'how much' source separation is carried out, but rather on 'how' a given SSL is reached.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Balancing Flexible Side Chains on 2D Conjugated Acceptors Enables High‐Performance Organic Solar Cell

Abstract Balancing the rigid backbones and flexible side chains of light‐harvesting materials is crucially important to reach optimized intermolecular packing, micromorphology, and thus photovoltaic performance of organic solar cells (OSCs). Herein, based on a distinctive CH‐series acceptor platform with 2D conjugation extended backbones, a series of nonfullerene acceptors (CH‐6F‐Cn) are synthesized by delicately tuning the lengths of flexible side chains fromn‐octyl ton‐amyl. A systemic investigation has revealed that the variation of the side chain's length can not only modulate intermolecular packing modes and crystallinity but also dramatically improve the micromorphology of the active layer and eventual photovoltaic parameters of OSCs. Consequently, the highest PCE of 18.73% can be achieved by OSCs employingD18:PM6:CH‐6F‐C8as light‐harvesting materials.

Chemistry↗

Quantifying Temperature Dependence of Pu(IV) Absorbance Spectra for Advanced Online Monitoring of Nuclear Processes

This article presents a systematic study of Pu(IV) absorbance spectral features as a function of temperature to develop an understanding of this parameter’s effect on chemometric models that can be used as online monitoring tools to support nuclear processing. The descriptive and predictive models that provide real-time feedback of these processes are usually constructed with data collected in conditions typical of a laboratory environment, which can differ drastically from a processing environment. To assess the impact of temperature on Pu(IV) absorbance spectra, 11 samples of Pu(IV) were synthesized with varying HNO 3 concentrations ranging from 0.6 to 9.5 M and heated between 15 and 45 °C. Ultraviolet (UV)–visible (vis)–near-infrared (NIR) absorption spectra collected at different HNO 3 concentrations and temperatures revealed that features associated with Pu(IV) are sensitive to temperature at all HNO 3 concentrations and that changes in features depend on HNO 3 concentration. The contributions of temperature and HNO 3 concentration to variation in Pu(IV) spectral features were evaluated using the principal component analysis of spectra that were baseline-corrected with an asymmetric least-squares method. Furthermore, predictive modeling for HNO 3 concentration with partial least-squares regression of UV–vis–NIR spectra highlighted the importance of accounting for temperature in the calibration set to optimize model performance. This methodology constitutes a new, systematic approach to account for the effect of temperature on the absorption spectra of metal ions and is useful for process monitoring applications in many industries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Excited-State Diffusion Monte Carlo Calculations: A Simple and Efficient Two-Determinant Ansatz

We perform excited-state variational Monte Carlo and diffusion Monte Carlo calculations using a simple and efficient wave function ansatz. This ansatz follows the recent variation-after-response formalism, accurately approximating a configuration interaction singles wave function as a sum of only two nonorthogonal Slater determinants and further including important orbital relaxation. The ansatz is used to perform diffusion Monte Carlo calculations with large augmented basis sets, comparing to benchmarks from near-exact quantum chemical methods. Here, the significance of orbital optimization in excited-state diffusion Monte Carlo is demonstrated, and the excited-state optimization procedure is discussed in detail. Diffuse excited states in water and formaldehyde are studied, in addition to the formaldimine and benzonitrile molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tree Growth--Hybrid Genetic Algorithm for Predicting the Structure of Small (TiO₂) n , n = 2-13, Nanoclusters

The initial structures for the search for the global minimum of TiO₂ nanoclusters were generated by combining a tree growth (TG) algorithm with a hybrid genetic algorithm (HGA). In the TG algorithm, the clusters grow from a small seed to the size of interest stepwise. New atoms are added to the smaller cluster from the previous step, by analogy to new leaves grown by a tree. The addition of the new atoms is controlled by predefined geometry parameters to reduce the computational cost and to provide physically meaningful structures. In each step, the energies for the various generated structures are evaluated, and those with the lowest energies are carried into the next step. The structures that match the formulas of interest are collected as HGA candidates during the various steps. Low energy candidates are fed to the HGA component to search for the global minimum for each formula of interest. The lowest energy structures from the HGA are then optimized by using density functional theory to study the dissociation energies of the clusters and the evolution in the structure as the size of the cluster increases. The optimized geometries of the (TiO₂)n nanoclusters for n = 2-13, do not show the character of a TiO₂ bulk crystal with a hexacoordinate Ti. The average clustering energy (ΔEn) converges slowly to the bulk value for rutile. The TiO₂ dissociation energies for (TiO₂)n clusters approach the bulk value for rutile more quickly but show larger variations. The (TiO₂)12 cluster appears to be quite stable, and the (TiO₂)13 cluster is quite unstable on a relative scale.

Environmental Molecular Sciences Laboratory↗

High-stability cryogenic scanning tunneling microscope based on a closed-cycle cryostat

We report on the design and operation of a cryogenic ultra-high vacuum (UHV) scanning tunneling microscope (STM) coupled to a closed-cycle cryostat (CCC). The STM is thermally linked to the CCC through helium exchange gas confined inside a volume enclosed by highly flexible rubber bellows. The STM is thus mechanically decoupled from the CCC, which results in a significant reduction of the mechanical noise transferred from the CCC to the STM. Noise analysis of the tunneling current shows current fluctuations up to 4% of the total current, which translates into tip-sample distance variations of up to 1.5 picometers. This noise level is sufficiently low for atomic-resolution imaging of a wide variety of surfaces. To demonstrate this, atomic-resolution images of Au(111) and NaCl(100)/Au(111) surfaces, as well as of carbon nanotubes deposited on Au(111), were obtained. Thermal drift analysis showed that under optimized conditions, the lateral stability of the STM scanner can be as low as 0.18 Å/h. Scanning Tunneling Spectroscopy measurements based on the lock-in technique were also carried out, and showed no detectable presence of noise from the closed-cycle cryostat. Using this cooling approach, temperatures as low as 16 K at the STM scanner have been achieved, with the complete cool-down of the system typically taking up to 12 h. These results demonstrate that the constructed CCC-coupled STM is a highly stable instrument capable of highly detailed spectroscopic investigations of materials and surfaces at the atomic scale.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation and mitigation of RF-plasma-induced damage to III-nitrides grown by molecular beam epitaxy

In this work, radio-frequency (RF) plasma-induced damage to III-nitride surfaces and bulk defects is observed and mitigated. It is shown that for InN films, the surface is more sensitive to plasma-induced damage than GaN films, as observed via atomic force microscopy and reflection high energy electron diffraction. In order to isolate any possible plasma-induced damage, a growth window for InN is established, and temperature ranges are determined for other damaging effects which include roughening due to low adatom mobility, InN decomposition, and indium desorption. In situ plasma monitoring and optimization are accomplished with a combination of optical emission spectroscopy as well as a remote Langmuir probe. It is shown that by increasing the plasma nitrogen flow, the positive ion content increases; however, the ion acceleration potential reduces. Additionally, a reduced RF plasma power results in a reduction of atomic nitrogen species. These plasma species and energetic variations result in variations in the bulk unintentional background electron concentrations observed by room temperature Hall effect measurements of ~1 um thick InN films. By increasing the nitrogen flow from 2.5 to 7.5 sccm for a constant RF power of 350 W, the background electron concentration decreases by 74% from 1.36 x 1019 cm-3 to 3.54 x 1018 cm-3, while maintaining a smooth surface morphology. Additionally, photoluminescence spectra indicate optical emission energies shift from ~0.81 to 0.71 eV (closer to the fundamental bandgap of InN) by limiting the damaging plasma species. Finally, conditions are presented to further minimize plasma-induced damage in III-nitride devices.

36 MATERIALS SCIENCE↗

Dosimetric evaluation of intrafractional tumor motion by means of a robot driven phantom

Purpose: The aim of the work was to investigate the influence of intrafractional tumor motion to the accumulated (absorbed) dose. The accumulated dose was determined by means of calculations and measurements with a robot driven motion phantom. Methods: Different motion scenarios and compensation techniques were realized in a phantom study to investigate the influence of motion on image acquisition, dose calculation, and dose measurement. The influence of motion on the accumulated dose was calculated by employing two methods (a model based and a voxel based method). Results: Tumor motion resulted in a blurring of steep dose gradients and a reduction of dose at the periphery of the target. A systematic variation of motion parameters allowed the determination of the main influence parameters on the accumulated dose. The key parameters with the greatest influence on dose were the mean amplitude and the pattern of motion. Investigations on necessary safety margins to compensate for dose reduction have shown that smaller safety margins are sufficient, if the developed concept with optimized margins (OPT concept) was used instead of the standard internal target volume (ITV) concept. Both calculation methods were a reasonable approximation of the measured dose with the voxel based method being in better agreement with the measurements. Conclusions: Further evaluation of available systems and algorithms for dose accumulation are needed to create guidelines for the verification of the accumulated dose.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-C-207-03: Optimization of a Collimator-Based Sparse Sampling Technique for Low-Dose Cone-Beam CT

Purpose: In computed tomography (CT) imaging, radiation dose delivered to the patient is one of the major concerns. Sparse-view CT takes projections at sparser view angles and provides a viable option to reducing dose. However, a fast power switching of an X-ray tube, which is needed for the sparse-view sampling, can be challenging in many CT systems. We have earlier proposed a many-view under-sampling (MVUS) technique as an alternative to sparse-view CT. In this study, we investigated the effects of collimator parameters on the image quality and aimed to optimize the collimator design. Methods: We used a bench-top circular cone-beam CT system together with a CatPhan600 phantom, and took 1440 projections from a single rotation. The multi-slit collimator made of tungsten was mounted on the X-ray source for beam blocking. For image reconstruction, we used a total-variation minimization (TV) algorithm and modified the backprojection step so that only the measured data through the collimator slits are to be used in the computation. The number of slits and the reciprocation frequency have been varied and the effects of them on the image quality were investigated. We also analyzed the sampling efficiency: the sampling density and data incoherence in each case. We tested three sets of slits with their number of 6, 12 and 18, each at reciprocation frequencies of 10, 30, 50 and 70 Hz/ro. Results: Consistent results in the image quality have been produced with the sampling efficiency, and the optimum condition was found to be using 12 slits at 30 Hz/ro. As image quality indices, we used the CNR and the detectability. Conclusion: We conducted an experiment with a moving multi-slit collimator to realize a sparse-sampled cone-beam CT. Effects of collimator parameters on the image quality have been systematically investigated, and the optimum condition has been reached.

60 APPLIED LIFE SCIENCES↗