Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Astrodynamics 1975; Conference, Nassau, Bahamas, July 28-30, 1975, Technical Papers

Articles are grouped under four headings: (1) dynamics and control of satellites; (2) satellite mission analysis; (3) Aeros-B and Symphonie satellite engineering problems; (4) optimization and control techniques applied to solar space heating and cooling of buildings. Topics covered include: communications and earth survey satellite systems, a system of two counter-orbiting satellites measuring GRT-predicted nodal drag, statistical mechanics studies of the spatial density function of orbiting space junk, attitude control of satellites, nutation dampers, low thrust inertial guidance and ascent inertial guidance, a shuttle-launched multi-comet intercept mission, preflight and in-flight analysis of the Atmosphere Explorer (AE-C) satellite, and launch-encounter strategy for the Mariner 1977 Jupiter-Saturn mission. Individual items are announced in this issue.

Powers, W. F.↗

Local control of defects and switching properties in ferroelectric thin films

Electric-field switching of polarization is the building block of a wide variety of ferroelectric devices. In turn, understanding the factors affecting ferroelectric switching and developing routes to control it are of great technological significance. This research provides systematic experimental evidence of the role of defects in affecting ferroelectric-polarization switching and utilizes the ability to deterministically create and spatially locate point defects in $PbZr_{0.2}Ti_{0.8}O_3$ thin films via focused-helium-ion bombardment and the subsequent defect-polarization coupling as a knob for on-demand control of ferroelectric switching (e.g., coercivity and imprint). At intermediate ion doses ($0.22-2.2×10^{14}\,ions\,cm^{-2}$), the dominant defects (isolated point defects and small clusters) show a weak interaction with domain walls (pinning potentials from $200-500\,K\,MV\,cm^{-1}$), resulting in small and symmetric changes in the coercive field. At high doses ($0.22-1×10^{15}\,ions\,cm^{-2}$), on the other hand, the dominant defects (larger defect complexes and clusters) strongly pin domain-wall motion (pinning potentials from 500 to $1600\,K\,MV\,cm^{-1}$), resulting in a large increase in the coercivity and imprint, and a reduction in the polarization. This local control of ferroelectric switching provides a route to produce novel functions; namely, tunable multiple polarization states, rewritable pre-determined 180° domain patterns, and multiple zero-field piezoresponse and permittivity states. Such an approach opens up pathways to achieve multilevel data storage and logic, nonvolatile self-sensing shape-memory devices, and nonvolatile ferroelectric field-effect transistors.

36 MATERIALS SCIENCE↗

Low-Emissivity, Energy-Control, Retrofit Window Film: Final Report

Solutia Performance Films, utilizing funding from the U.S. Department of Energy's Buildings Technologies Program, completed research to develop, validate, and commercialize a range of cost-effective, low-emissivity energy-control retrofit window films with significantly improved emissivity over current technology. These films, sold under the EnerLogic® trade name, offer the energy-saving properties of modern low-e windows, with several advantages over replacement windows, such as: lower initial installation cost, a significantly lower product carbon footprint, and an ability to provide a much faster return on investment. EnerLogic® window films also offer significantly greater energy savings than previously available with window films with similar visible light transmissions. EnerLogic® window films offer these energy-saving advantages over other window films due to its ability to offer both summer cooling and winter heating savings. Unlike most window films, that produce savings only during the cooling season, EnerLogic® window film is an all-season, low-emissivity (low-e) film that produces both cooling and heating season savings. This paper will present technical information on the development hurdles as well as details regarding the following claims being made about EnerLogic® window film, which can be found at www.EnerLogicfilm.com: 1. Other window film technologies save energy. EnerLogic® window film's patent-pending coating delivers excellent energy efficiency in every season, so no other film can match its annual dollar or energy consumption savings. 2. EnerLogic® window film is a low-cost, high-return technology that compares favorably to other popular energy-saving measures both in terms of energy efficiency and cost savings. In fact, EnerLogic® window film typically outperforms most of the alternatives in terms of simple payback. 3. EnerLogic® window film provides unparalleled glass insulating capabilities for window film products. With its patent-pending low-e technology, EnerLogic® window film has the best insulating performance of any film product available. The insulating power of EnerLogic® window film gives single-pane windows the annual insulating performance of double-pane windows - and gives double-pane windows the annual insulating performance of triple-pane windows.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

EVs@Scale Lab Consortium High-Power Charging Pillar Deep-Dive Technical Meeting

Managed under the the U.S. Department of Energy (DOE)-funded EVs@Scale Consortium, the High-Power Electric Vehicle Charging Hub Integration Platform (eCHIP) project aims to create an experimental platform for integration and control approaches in a direct current (DC), distribution-based high-power charging (HPC) system. The eCHIP project addresses the crucial need to design and validate efficient, low-cost, reliable, and interoperable solutions for a DC-coupled charging hub ("DC hub" for short). This report explains the design, development, and implementation process of an experimental platform for the DC hub. DC distribution holds significant potential for enhancing the operation of an HPC station architecture. However, there are challenges in establishing a DC hub, including interoperability, commoditization, distributed energy resource integration, stability, DC protection, and a lack of common system-level controllers. To address these challenges, a testing setup is required that accommodates commercial off-the-shelf (COTS) products, as well as novel, in-house designed solutions, to evaluate different use cases at rated power and voltage levels. The developed proof-of-concept charging platform and open-source SEMS allow the development and testing of various controllers and chargers from different vendors. The DC hub platform integrated EVs, an ESS, a PV system, and building load to demonstrate the flexibility of the platform. The open-source SEMS controlled the devices within the hub using a rule-based implementation, realizing available standards.

ADVANCED PROPULSION SYSTEMS↗

Managing Army Plug Load Equipment Energy Use: Breakroom Appliances

Breakroom equipment is the third highest energy-consuming plug load category in Army buildings. In addition to the vending machine measures described separately, improved purchasing and control measures for breakroom appliances can save the Army more than 9 million kWh and $550K per year in the building types evaluated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Deep Reinforcement Learning for Autonomous Water Heater Control

Electric water heaters represent 14% of the electricity consumption in residential buildings. An average household in the United States (U.S.) spends about USD 400–600 (0.45 ¢/L–0.68 ¢/L) on water heating every year. In this context, water heaters are often considered as a valuable asset for Demand Response (DR) and building energy management system (BEMS) applications. To this end, this study proposes a model-free deep reinforcement learning (RL) approach that aims to minimize the electricity cost of a water heater under a time-of-use (TOU) electricity pricing policy by only using standard DR commands. In this approach, a set of RL agents, with different look ahead periods, were trained using the deep Q-networks (DQN) algorithm and their performance was tested on an unseen pair of price and hot water usage profiles. The testing results showed that the RL agents can help save electricity cost in the range of 19% to 35% compared to the baseline operation without causing any discomfort to end users. Additionally, the RL agents outperformed rule-based and model predictive control (MPC)-based controllers and achieved comparable performance to optimization-based control.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Role of Process Control in Improving Space Vehicle Safety A Space Shuttle External Tank Example

Developing a safe and reliable space vehicle requires good design and good manufacturing, or in other words "design it right and build it right". A great design can be hard to build or manufacture mainly due to difficulties related to quality. Specifically, process control can be a challenge. As a result, the system suffers from low quality which leads to low reliability and high system risk. The Space Shuttle has experienced some of those cases, but has overcome these difficulties through extensive redesign efforts and process enhancements. One example is the design of the hot gas temperature sensor on the Space Shuttle Main Engine (SSME), which resulted in failure of the sensor in flight and led to a redesign of the sensor. The most recent example is the Space Shuttle External Tank (ET) Thermal Protection System (TPS) reliability issues that contributed to the Columbia accident. As a result, extensive redesign and process enhancement activities have been performed over the last two years to minimize the sensitivities and difficulties of the manual TPS application process.

Safie, Fayssal M.↗

Dynamic Assurance of Autonomous Systems through Ground Control Software

Assurance cases are being increasingly acknowledged as a way to build trust in complex systems with autonomous capabilities [1]. An assurance case is a comprehensive, defensible, and valid justification that a system will function as intended for the specific mission and operating environment. Such justifications for systems with autonomous capabilities are often based on various probabilistic quantifications [2]. Due to the dynamic nature of the environmental conditions in which these systems operate, as well as the changing nature of the autonomous systems themselves, these probabilistic quantifications cannot be simply estimated once during design time. Rather, they need to be continually evaluated during systems operations to ensure that the assurance case justifications are valid. We refer to the assurance case that combines both the static and dynamic elements as a Dynamic Assurance Case (DAC). Such complex systems with autonomous capabilities are often deployed with a Ground Control Software (GCS) component to enable remote operation. Whether the system is composed of a single unit or a fleet of units, deployed distributed or in remote environments, GCS acts as a window into the behavior of the deployed system. It receives telemetry from the system, issues commands to the system and provides various functionalities to visualize the system performance. We propose a dynamic assurance framework where the GCS acts as a relay between the autonomous system and its DAC. GCS can be used to measure both unit-specific as well as system-wide probabilistic quantifications using the incoming telemetry. We embed these quantifications throughout the DAC as variables that can be updated by external sources. We use the GCS to periodically update these variables, which allows us to continually evaluate the formally defined assurance case justifications. We demonstrate our dynamic assurance framework in the NASA Ames project Troupe1 that aims at developing a fleet of rovers capable of au- tonomously mapping their environment. The rovers work cooperatively, each collecting data for different parts of the environment. Each rover runs an identical core Flight System (cFS) [4] application. Troupe1 uses OpenC3 Cosmos [5] as the ground system, and AdvoCATE [3] to capture the system DAC. We show how we can measure both rover-specific and system-wide quantifications in Cosmos using its Ruby scripting editor and pass them into the DAC modelled in AdvoCATE. Then, we show how these incoming variables can be embedded in different parts of the DAC and how effects of their updates can be observed

Irfan Sljivo↗

Quantification of Load Flexibility in Residential Buildings Using Home Energy Management Systems

With increasing penetration of renewable energy resources, the flexibility of operating behind-the-meter (BTM) resources plays a key role in enhancing grid reliability and resilience. Residential buildings with home energy management systems (HEMS) can provide desired flexibility for the distribution system operator (DSO) while considering customer comfort and preferences. This paper discusses a methodology to quantify the flexibility of BTM resources of residential buildings using HEMS. First, we propose a model predictive control framework to formulate the flexibility band comprising nominal, upper, and lower demand profiles. Second, the paper proposes a dispatch method for HEMS to compute the control signals for each BTM resource (e.g., air conditioner, water heater, home battery system) upon receiving a flexibility service request from the DSO. The case study provides insight into the flexibility provided at the whole-home level with different user preferences and seasons. The results demonstrate that HEMS is capable of providing flexibility service at the request of the DSO while delivering primary services to the building occupants.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Development of the Resource Prospector Planetary Rover

The Resource Prospector (RP) is an In-­‐Situ Resource Utilization (ISRU) lunar rover mission under study by NASA. RP is planned to launch in 2020 to prospect for subsurface volatiles and to extract oxygen from lunar regolith. The mission will address several of NASA's "Strategic Knowledge Gaps" for lunar exploration. The mission will also address the Global Exploration Roadmap's strategic goal of using local resources for human exploration. The distribution of lunar subsurface volatiles drives the mission requirement for mobility. The spatial distribution is hypothesized to be governed by impact cratering with the top 0.5 m being patchy at scales of 100 m. The mixing time scale increases with depth (less frequent larger impacts). Consequently, increased mobility reduces the depth requirement for sampling. The target RP traverse will extend 1 km radially from the landing site to sample craters of varying sizes. Sampling craters with different ages will reveal possible volatile emplacement history. In 1 Ga, approximately 60-­70 craters of 10 m diameter form per km2. Thus, the rover will need to sample at least ten of these craters, which may require a total traverse path length of 2-­‐3 km. During 2014-­2015, we developed an initial prototype rover for RP. The current design is a solar powered, four-­wheeled vehicle, with hub motor drive, offset four wheel steering, and active suspension. Active suspension provides capabilities including changing vehicle ride height, traversing comparatively large obstacles, and controlling load on the wheels. All-­wheel steering enables the vehicle to point arbitrarily while roving, e.g., to keep the solar array pointed at the sun while in motion. The offset steering combined with active suspension improves driving in soft soil. The rover's on-­board software utilizes NASA's Core Flight Software, which is a reusable flight software environment. During 2015, we completed the initial rover software build, which provides low-­level hardware interfaces, basic mobility control, waypoint driving, odometry, basic error checking, and camera services. Development of the prototype rover has enabled maturation of many of the subsystems to TRL 5. During the next year, we will conduct integrated testing of concepts of operation, navigation, and remote driving tools. In addition, we will perform environmental tests including radiation (avionics), thermal and thermal/vacuum (mechanisms), and gravity offload (mobility).

robotics↗

Implementation of ASHRAE Guideline 36 Control Logic into Oak Ridge National Laboratory (ORNL)’s Flexible Research Platform (FRP)

This report presents the initial field test procedure and results for ASHRAE Guideline 36 control logic. The US Department of Energy’s Oak Ridge National Laboratory’s (ORNL’s) two-story Flexible Research Platform (FRP-2) was selected as a test building. The rooftop unit (RTU) system serves as the building’s primary cooling system, and each variable air volume (VAV) box with an electric reheat coil serves as the building’s heating system along with RTU gas furnace. In this study, the control for the RTU and VAV box adopted the practical control sequences from ASHRAE Guideline 36-2018: High-Performance Sequences of Operation. Each story of the FRP-2 building has 5 office zones (thermal zones), for a total of 10 zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Use Intensity and its Influence on the Integrated Daylighting Design of a Large Net Zero Energy Building: Preprint

Net-zero energy buildings generate as much energy as they consume and are significant in the sustainable future of building design and construction. The role of daylighting (and its simulation) in the design process becomes critical. In this paper we present the process the National Renewable Energy Laboratory embarked on in the procurement, design, and construction of its newest building, theResearch Support Facility (RSF) - particularly the roles of daylighting, electric lighting, and simulation. With a rapid construction schedule, the procurement, design, and construction had to be tightly integrated; with low energy use. We outline the process and measures required to manage a building design that could expect to operate at an efficiency previously unheard of for a building ofthis type, size, and density. Rigorous simulation of the daylighting and the electric lighting control response was a given, but the oft-ignored disconnect between lighting simulation and whole-building energy use simulation had to be addressed. The RSF project will be thoroughly evaluated for its performance for one year; preliminary data from the postoccupancy monitoring efforts will also bepresented with an eye toward the current efficacy of building energy and lighting simulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Temporal Galactose‐Manganese Feeding in Fed‐Batch and Perfusion Bioreactors Modulates UDP‐Galactose Pools for Enhanced mAb Glycosylation Homogeneity

ABSTRACT Monoclonal antibodies (mAbs) represent a majority of biotherapeutics in the market today. These glycoproteins undergo posttranslational modifications, such as N‐linked glycosylation, that influence the structural & functional characteristics of the antibody. Glycosylation is a heterogenous posttranslational modification that may influence therapeutic glycoprotein stability and clinical efficacy, which is why it is often considered a critical quality attribute (CQA) of the mAb product. While much is known about the glycosylation pathways of Chinese Hamster Ovary (CHO) cells and how cell culture chemical modifiers may influence the N‐glycosylation profile of the final product, this knowledge is often based on the final cumulative glycan profile at the end of the batch process. Building a temporal understanding of N‐glycosylation and how mAb glycoform composition responds to real‐time changes in the biomanufacturing process will help build integrated process models that may allow for glycosylation control to produce a more homogenous product. Here, we look at the effect of specific nutrient feed media additives (e.g., galactose, manganese) and feeding times on the N‐glycosylation pathway to modulate N‐glycosylation of a Herceptin biosimilar mAb (i.e., Trastuzumab). We deploy the N‐GLYcanyzer process analytical technology (PAT) to monitor glycoforms in near real‐time for bench‐scale bioprocesses operated in both fed‐batch and perfusion modes to build an understanding of how temporal changes in mAb N‐glycosylation are dependent on specific media additives. We find that Trastuzumab terminal galactosylation is sensitive to media feeding times and intracellular nucleotide sugar pools. Temporal analysis reveals an increased desirable production of single and double galactose‐occupied glycoforms over time under glucose‐starved fed‐batch cultures. Comparable galactosylation profiles were also observed between fed‐batch (nutrient‐limited) and perfusion (non‐nutrient‐limited) bioprocess conditions. In summary, our results demonstrate the utility of real‐time monitoring of mAb glycoforms and feeding critical cell culture nutrients under fed‐batch and perfusion bioprocessing conditions to produce higher‐quality biologics.

Biotechnology & Applied Microbiology↗

Walking the ‘design–build–test–learn’ cycle: flux analysis and genetic engineering reveal the pliability of plant central metabolism

Oilseeds are of great economic importance for food and animal feed and their contribution to renewable energy production. Soybean seeds (Glycine max (L.) Merr.) contain c. 40% protein, 20% oil, and 30% carbohydrate (Song et al., 2023). Due to the massive scale of soybean production worldwide, even small improvements in seed protein and oil content make economic sense (Song et al., 2023). Successful manipulation of seed composition largely depends on a thorough understanding of the processes and pathways involved in the biosynthesis of fatty acids and amino acids, which are the building blocks of lipids and proteins. Rational engineering of the synthesis of storage reserves, that is, the rerouting of metabolic flux in central metabolism, is difficult to accomplish due to the complexity of the central metabolic network, the intricate regulation of its enzymes at multiple levels, and the often-unpredictable effects of genetic manipulation (Sweetlove et al., 2017). Therefore, the advancement of our understanding of central metabolism and its control of carbon partitioning requires following an iterative ‘design–build–test–learn’ (DBTL) cycle (Lin & Eudes, 2020) where metabolic flux analysis and hypothesis testing by transgenic approaches are important components. Previous metabolic studies on soybeans using isotopic tracers and metabolic flux analysis have provided insight into how lipid and protein biosynthesis occurs simultaneously during seed development (Allen et al., 2009; Allen & Young, 2013; Kambhampati et al., 2021). In an article published in this issue of New Phytologist, Morley et al. (2023; 1834–1851) put the insights they have gained into the delivery of metabolic precursors and energy cofactors to oil synthesis to the test and arrive at a successful metabolic engineering design. They show that an increase in seed oil content in soybeans can be achieved by overexpression of malic enzyme (ME) during seed development. Malic enzyme refers to a class of decarboxylating malate dehydrogenase enzymes that oxidize malate with NAD + or NADP + as redox cofactor while generating pyruvate and CO 2 . Like higher plants in general, soybean has distinct NADH- or NADPH-producing ME isoforms localized to the cytosol, plastid, or mitochondria (Gerrard Wheeler et al., 2016). As Morley et al. show, an increase in seed oil can be achieved in particular when a NADP+-dependent enzyme isoform (EC 1.1.1.40) is overexpressed in the plastid. Given the complex compartmentalization of pyruvate, malate, and redox metabolism (Fig. 1), increased oil production appears to depend on additional pyruvate and reducing equivalents being produced in the same compartment where de novo fatty acid biosynthesis occurs: the plastid.

59 BASIC BIOLOGICAL SCIENCES↗

Solar plus: Optimization of distributed solar PV through battery storage and dispatchable load in residential buildings

As utility electricity rates evolve, pairing solar photovoltaic (PV) systems with battery storage has potential to ensure the value proposition of residential solar by mitigating economic uncertainty. In addition to batteries, load control technologies can reshape customer load profiles to optimize PV system use. The combination of PV, energy storage, and load control provides an integrated approach to PV deployment, which we call 'solar plus'. The U.S. National Renewable Energy Laboratory's Renewable Energy Optimization (REopt) model is utilized to evaluate cost-optimal technology selection, sizing, and dispatch in residential buildings under a variety of rate structures and locations. The REopt model is extended to include a controllable or 'smart' domestic hot water heater model and smart air conditioner model. We find that the solar plus approach improves end user economics across a variety of rate structures - especially those that are challenging for PV - including lower grid export rates, non-coincident time-of-use structures, and demand charges.

14 SOLAR ENERGY↗

Routes to spatiotemporal chaos in Kerr optical frequency combs

We investigate the various routes to spatiotemporal chaos in Kerr optical frequency combs, obtained through pumping an ultra-high Q-factor whispering-gallery mode resonator with a continuous-wave laser. The Lugiato–Lefever model is used to build bifurcation diagrams with regards to the parameters that are externally controllable, namely, the frequency and the power of the pumping laser. We show that the spatiotemporal chaos emerging from Turing patterns and solitons display distinctive dynamical features. Experimental spectra of chaotic Kerr combs are also presented for both cases, in excellent agreement with theoretical spectra.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Standard Modular Architecture for Consumer End Plug and Play Interfaces

The growth in load and generation sources at the edge of the grid is driving the innovation in power electronic (PE) grid interfaces at the consumer end to improve the grid resiliency, reliability, security, and cost of the future infrastructure. Novel PE technologies are key enablers for the future grid infrastructure to handle the issues that arise because of the projected growth. This paper introduces a novel fundamental building block (FBB) architecture with plug-and play features. An example framework that enables co-ordination of multiple FBBs hierarchically to provide various grid functions is also presented. The FBBs are designed to be equipped with advanced features like online health monitoring, embedded intelligence, and decision-making capability for enhancing the metrics of consumer end plug and play interfaces. The paper elaborates on the proposed architecture and the developed framework i.e., the controls, communication, protection, and the corresponding timing requirements for the building blocks. The architecture and the framework have been validated through simulations and the communication framework has been validated with a control hardware in the loop platform.

Chinthavali, Madhu Sudhan↗

Completing the Connected Home with Smart Window Shades

Heat transfer through windows accounts for a significant percentage of a building’s energy use and adds substantially to the peak cooling load of a home. Window attachment manufacturers currently offer motorized shading devices for certain product lines, but this automation is typically marketed as a convenience and security feature for the homeowner and often does not include energy optimized control algorithms or dynamic and responsive features. This paper describes the experimental results of testing the energy performance of high-efficiency, dynamically operated, cellular shades in Pacific Northwest National Laboratory’s (PNNL) Lab Homes. The results of both heating and cooling season experiments will be presented, where testing is designed to assess the whole home energy savings resulting from both the thermal insulating properties as well as the automated and dynamic control strategies of shading devices. Control schemes tested include common “connected home” strategies where controls are integrated and coordinated between the window shading device, building thermostats, and external sensors. The presentation will also include results from testing designed to examine the benefits (in terms of comfort, energy savings, and responsiveness) of coordinating the operation of cellular shades with HVAC as a demand-response measure. These experiments demonstrate that highly insulating, dynamic window coverings that are reliably controlled can dramatically reduce the heating and cooling energy associated with windows and should be considered an important component of any “smart” home design.

energy savings, cellular shades, honeycomb shades,↗