Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONVENTIONAL RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Flying focus with arbitrary directionality for spatiotemporal control of laser intensity

Flying focus techniques produce laser pulses whose focal points travel at arbitrary, controllable velocities. While this flexibility can enhance a broad range of laser-based applications, existing techniques constrain the motion of the focal point to the propagation direction of the pulse. Here, we introduce a flying focus configuration that decouples the motion of the focus from the propagation direction. Here, a chirped laser pulse focused and diffracted by a diffractive lens and grating creates a focal point that can move both along and transverse to the propagation direction. The focal length of the lens, grating period, and chirp can be tuned to control the direction and velocity of the focus. Simulations demonstrate this control for a holographic configuration suited to high-power pulses, in which two off-axis pump beams with different focal lengths encode the equivalent phase of a chromatic lens and grating in a gas or plasma. For low-power pulses, conventional solid-state or adaptive optics can be used instead. Multi-dimensional control over the focal trajectory enables new configurations for applications, including laser wakefield acceleration of ions, nonlinear Thomson scattering, and surface-plasmon emission of THz radiation.

Classical optics↗

Snowflake divertor experiments in the DIII-D, NSTX, and NSTX-U tokamaks aimed at the development of the divertor power exhaust solution

Experimental results from the National Spherical Torus Experiment (NSTX), a medium-size spherical tokamak with a compact divertor, and DIII-D, a large conventional aspect ratio tokamak, demonstrate that the snowflake (SF) divertor configuration may provide a promising solution for mitigating divertor heat loads and target plate erosion compatible with core H-mode confinement in the future fusion devices, where the standard radiative divertor solution may be inadequate. In NSTX, where the initial high-power SF experiment was performed, the SF divertor was compatible with H-mode confinement, and led to the destabilization of large Edge Localized Modes (ELMs). However, a stable partial detachment of the outer strike point was also achieved where inter-ELM peak heat flux was reduced by factors 3-5, and peak ELM heat flux was reduced by up to 80% (see standard divertor). The DIII-D studies show the SF divertor enables significant power spreading in attached and radiative divertor conditions. Results include: compatibility with the core and pedestal, peak inter-ELM divertor heat flux reduction due to geometry at lower ne, and ELM energy and divertor peak heat flux reduction, especially prominent in radiative D 2 -seeded SF divertor, and nearly complete power detachment and broader radiated power distribution in the radiative D 2 -seeded SF divertor at PSOL = 3 - 4 MW. A variety of SF configurations can be supported by the divertor coil set in NSTX Upgrade. Edge transport modeling with the multifluid edge transport code UEDGE shows that the radiative SF divertor can successfully reduce peak divertor heat flux for the projected PSOL ≃ 9 MW case. Furthermore, the radiative SF divertor with carbon impurity provides a wider ne operating window, 50% less argon is needed in the impurity-seeded SF configuration to achieve similar q peak reduction factors (see standard divertor).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-F-J-44: Development of a Room Laser Based Real-Time Alignment Monitoring System Using An Array of Photodiodes

Purpose: To develop a real-time alignment monitoring system (RAMS) to compensate for the limitations of the conventional room laser based alignment system, and to verify the feasibility of the RAMS. Methods: The RAMS was composed of a room laser sensing array (RLSA), an analog-todigital converter, and a control PC. In the RLSA, seven photodiodes (each in 1 mm width) are arranged in a pattern that the RAMS provides alignment in 1 mm resolution. It works based on detecting laser light aligned on one of photodiodes. When misaligned, the laser would match with different photodiode(s) giving signal at unexpected location. Thus, how much displaced can be determined. To verify the reproducibility of the system with respect to time as well as repeated set-ups, temporal reproducibility and repeatability test was conducted. The accuracy of the system was tested by obtaining detection signals with varying laser-match positions. Results: The signal of the RAMS was found to be stable with respect to time. The repeatability test resulted in a maximum coefficient of variance of 1.14%, suggesting that the signal of the RAMS was stable over repeated set-ups. In the accuracy test, signals between when the laser was aligned and notaligned with any of sensors could be distinguished by signal intensity. The signals of not-aligned sensors were always below 75% of the signal of the aligned sensor. It was confirmed that the system could detect 1 mm of movement by monitoring the pattern of signals, and could observe the movement of the system in real-time. Conclusion: We developed a room laser based alignment monitoring system. The feasibility test verified that the system is capable of quantitative alignment monitoring in real time. The system is relatively simple, not expensive, and considered to be easily incorporated into conventional room laser systems for real-time alignment monitoring. This research was supported by the Mid-career Researcher Program through NRF funded by the Ministry of Science, ICT & Future Planning of Korea (NRF-2014R1A2A1A10050270) and by the Radiation Technology R&D program through the National Research Foundation of Korea funded by the Ministry of Science, ICT & Future Planning (No. 2013M2A2A7038291)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis and Design of Ex-Service Garter Spring Irradiation Capsules in the High Flux Isotope Reactor

Nickel-based super alloys such as Inconel X-750 are used to fabricate internal components for various reactor systems. Recent efforts to research and understand the effects of long-term neutron radiation damage on this material are crucial for quantifying the performance (radiation-induced creep and embrittlement) of such materials under extended use. The CANDU® ex-service garter spring irradiation program was instituted to investigate such effects on various types of Inconel X-750 garter springs, tensile specimens, and fatigue specimens. Conventional irradiation programs use rabbits, which are capsules that are generally loaded with non radioactive irradiation specimens. These rabbits are designed to realize various specimen temperatures while irradiated to high neutron fluences in the Oak Ridge National Laboratory (ORNL) High Flux Isotope Reactor (HFIR). To accelerate the irradiation schedule of this program, two types of material — unirradiated and previously irradiated ex-service garter spring material — were both included in the irradiation program test matrix. These two material conditions are expected to provide intermediate and end-of-life neutron dose experimental results concurrently to accelerate the overall irradiation program schedule. This document describes the B8J18 garter spring design and the supporting work required to successfully fabricate, assemble, and qualify subsequent irradiation capsules.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Meson Spectroscopy: a Perspective from GlueX

In the last 15 years collaborations world-wide have contributed to the discovery of many exotic candidate states, such as those made from two quarks and two antiquarks. With these discoveries there has been renewed interest in spectroscopy and in particular, searches for other such particles. Thomas Jefferson National Accelerator Facility is home to the GlueX experiment which uses a 12 GeV electron beam incident on a diamond radiator to produce a linearly polarized, coherent Bremsstrahlung photon beam. The primary goal of GlueX is to search for so-called exotic hybrid mesons (comprised of a quark, an anti quark, and a gluon) by first mapping out the conventional spectrum of mesons starting with the often poorly understood excited vector mesons. Photoproduction at these energies is relatively unexplored and the use of a polarized beam allows GlueX to discriminate between various production mechanisms which may aid in the identification of exotic hybrid mesons. Successfully commissioned in 2015, GlueX has recently completed data taking for its first phase (GlueX-I) which represents orders of magnitude more statistics than previous photoproduction experiments. In this talk we will present an overview of the spectroscopy being performed at Jefferson Lab with a focus on GlueX.

Britton, Thomas↗

Accuracy of Vaisala RS41 and RS92 Upper Tropospheric Humidity Compared to Satellite Hyperspectral Infrared Measurements

Radiosondes are important for calibrating satellite sensors and assessing sounding retrievals. Vaisala RS41 radiosondes have mostly replaced RS92 in the Global Climate Observing System (GCOS) Reference Upper Air Network (GRUAN) and the conventional network. This study assesses RS41 and RS92 upper tropospheric humidity (UTH) accuracy by comparing with Infrared Atmospheric Sounding Interferometer (IASI) upper tropospheric water vapor absorption spectrum measurements. Using single RS41 and RS92 soundings at three GRUAN and DOE Atmospheric Radiation Measurement (ARM) sites and dual RS92/RS41 launches at three additional GRUAN sites, collocated with cloud-free IASI radiances (OBS), we compute Line-by-Line Radiative Transfer Model radiances for radiosonde profiles (CAL). We analyze OBS-CAL differences from 2015 to 2020, for daytime, nighttime, and dusk/dawn separately if data is available, for standard (STD) RS92 and RS41 processing, and RS92 GRUAN Data Processing (GDP; RS41 GDP is in development). We find that daytime RS41 (even without GDP) has ~1% smaller UTH errors than GDP RS92. RS41 may still have a dry bias of 1–1.5% for both daytime and nighttime, and a similar error for nighttime RS92 GDP, while standard RS92 may have a dry bias of 3–4%. These sonde humidity biases are probably upper limits since “cloud-free” scenes could still be cloud contaminated. Radiances computed from European Centre for Medium-Range Weather Forecasts (ECMWF) analyses match better than radiosondes with IASI measurements, perhaps because ECMWF assimilates IASI measurements. Relative differences between RS41 STD and RS92 GDP, or between radiosondes and ECMWF humidity profiles obtained from the radiance analysis, are consistent with their differences obtained directly from the RH measurements.

54 ENVIRONMENTAL SCIENCES↗

Laser Techniques in Photovoltaic Research

High-power laser pulses were used to replace the conventional high temperature furnace processing for the p-n junction formation step in high speed, low cost solar cell fabrication. Three different approaches to junction formation were tested: (1) laser annealing of ion-implanted Si in which laser radiation is used to remove the radiation damage and to recover the electrical activity in the implanted layer; (2) a process in which a thin film of dopant is first deposited on the substrate and then incorporated into the near-surface region by laser-induced diffusion; and (3) a process in which a heavily doped amorphous silicon layer is deposited on the Si substrate and epitaxially regrown from the melted substrate layer by laser radiation. All three methods were found to provide suitable candidates for high efficiency Si solar cells.

Young, R. T.↗

Heat flux at the thermionic collector

Heat flux arriving at the thermionic collector is theoretically considered to be composed of an electron heating term, proportional to the output current, plus the radiation and conduction terms. However, the measured electron heating term is always larger than what one would expect from the accepted theory. In this paper, the electron heating term at the collector is theoretically calculated as a sum of the conventional electron heating term and the heat flux which is carried into the collector by the random plasma current. The arriving random electrons and ions are considered to recombine nonradiatively at the collector surface after imparting their kinetic energies to the collector, in addition to the ionization potential energy. In this process, random electrons do not lose their potential energy equal to the collector work function, since they do not contribute to the output current.

Shimada, K.↗

Implementing the Simple Biosphere Model (SiB) in a general circulation model: Methodologies and results

The Simple Biosphere MOdel (SiB) of Sellers et al., (1986) was designed to simulate the interactions between the Earth's land surface and the atmosphere by treating the vegetation explicitly and relistically, thereby incorporating biophysical controls on the exchanges of radiation, momentum, sensible and latent heat between the two systems. The steps taken to implement SiB in a modified version of the National Meteorological Center's spectral GCM are described. The coupled model (SiB-GCM) was used with a conventional hydrological model (Ctl-GCM) to produce summer and winter simulations. The same GCM was used with a conventional hydrological model (Ctl-GCM) to produce comparable 'control' summer and winter variations. It was found that SiB-GCM produced a more realistic partitioning of energy at the land surface than Ctl-GCM. Generally, SiB-GCM produced more sensible heat flux and less latent heat flux over vegetated land than did Ctl-GCM and this resulted in the development of a much deeper daytime planetary boundary and reduced precipitation rates over the continents in SiB-GCM. In the summer simulation, the 200 mb jet stream and the wind speed at 850 mb were slightly weakened in the SiB-GCM relative to the Ctl-GCM results and equivalent analyses from observations.

Sato, N.↗

LEO effects on candidate solar cell cover materials

In 1984, the LDEF (Long Duration Exposure Facility) was placed in LEO (Low Earth Orbit) for a mission planned to last approximately one year. Due to a number of factors, retrieval was delayed until 1990. An experiment, prepared under the direction of JPL, consisted of a test plate with thirty (30) individual thin silicon solar cell/cover samples. The covers consisted of conventional cerium doped microsheet platelets and potential candidate materials, such as FEP Teflon, silicon RTV's, glass resins, polyimides, and a silicone-polyimide copolymer encapsulant. The effects of the LDEF mission environment (micrometeorite/debris impacts, atomic oxygen, UV, and particulate radiation) on the samples are discussed.

Stella, Paul M.↗

Design considerations for 0.1K bolometers

Bolometers operating at low temperatures (T greater than 0.3 K) are the best candidate for far infrared (lambda greater than or = 120 microns) and submillimeter detection from cold orbiting telescopes. The limits of sensitivity for such devices have been studied (Mather, 1983). Based on this work, we conclude that excellent sensitivity is possible given careful detector design. We have designed and are fabricating bolometers for operation at low temperatures. The crucial components in detector design are (1) heat capacity, (2) temperature sensing, and (3) absorption of infrared radiation. In this presentation, we discuss the choice of materials and fabrication techniques we have made in the interest of maximum sensitivity. In order that optimization of detector performance be reasonably easy to carry out, we have attempted to use conventional fabrication techniques wherever possible (photolithography, wire bonding). The use of such procedures allows us to make design changes on short time scales, which is essential in achieving optimal performance.

Moseley, Harvey↗

Multi-beam laser altimeter

Laser altimetry provides a high-resolution, high-accuracy method for measurement of the elevation and horizontal variability of Earth-surface topography. The basis of the measurement is the timing of the round-trip propagation of short-duration pulses of laser radiation between a spacecraft and the Earth's surface. Vertical resolution of the altimetry measurement is determined primarily by laser pulsewidth, surface-induced spreading in time of the reflected pulse, and the timing precision of the altimeter electronics. With conventional gain-switched pulses from solid-state lasers and sub-nsec resolution electronics, sub-meter vertical range resolution is possible from orbital attitudes of several hundred kilometers. Horizontal resolution is a function of laser beam footprint size at the surface and the spacing between successive laser pulses. Laser divergence angle and altimeter platform height above the surface determine the laser footprint size at the surface, while laser pulse repetition-rate, laser transmitter beam configuration, and altimeter platform velocity determine the space between successive laser pulses. Multiple laser transitters in a singlaltimeter instrument provide across-track and along-track coverage that can be used to construct a range image of the Earth's surface. Other aspects of the multi-beam laser altimeter are discussed.

Bufton, Jack L.↗

Stirling Radioisotope Power System as an Alternative for NASAs Deep Space Missions

The NASA Glenn Research Center (GRC) and the Department of Energy (DOE) are developing a free-piston Stirling convertor for a Stirling Radioisotope Power System (SRPS) to provide on-board electric power for future NASA deep space missions. The SRPS currently being developed provides about 100 watts and reduces the amount of radioisotope fuel by a factor of four over conventional Radioisotope Thermoelectric Generators (RTG). The present SRPS design has a specific power of approximately 4 W/kg which is comparable to an RTG. GRC estimates for advanced versions of the SRPS with improved heat source integration, lightweight Stirling convertors, composite radiators, and chip-packaged controllers improves the specific mass to about 8 W/kg. Additional information is contained in the original extended abstract.

Shaltens, R. K.↗

Stereotactic Body Radiation Therapy Boost in Locally Advanced Pancreatic Cancer

Purpose: To investigate the clinical application of a stereotactic body radiation therapy (SBRT) boost in locally advanced pancreatic cancer patients with a focus on local efficacy and toxicity. Methods and Materials: We retrospectively reviewed 30 patients with locally advanced and nonmetastatic pancreatic cancer who had been treated between 2004 and 2006. Follow-up duration ranged from 4 to 41 months (median, 14.5 months). A total dose of 40 Gy was delivered in 20 fractions using a conventional three-field technique, and then a single fraction of 14, 15, 16, or 17 Gy SBRT was administered as a boost without a break. Twenty-one patients received chemotherapy. Overall and local progression-free survival were calculated and prognostic factors were evaluated. Results: One-year overall survival and local progression-free survival rates were 60.0% and 70.2%, respectively. One patient (3%) developed Grade 4 toxicity. Carbohydrate antigen 19-9 response was found to be an independent prognostic factor for survival. Conclusions: Our findings indicate that a SBRT boost provides a safe means of increasing radiation dose. Based on the results of this study, we recommend that a well controlled Phase II study be conducted on locally advanced pancreatic cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase I-II Study of Intraoperative Radiation Therapy (IORT) After Radical Prostatectomy for Prostate Cancer

Purpose: Recent studies have suggested an {alpha}/{beta} ratio in prostate cancer of 1.5-3 Gy, which is lower than that assumed for late-responsive normal tissues. Therefore the administration of a single, intraoperative dose of irradiation should represent a convenient irradiation modality in prostate cancer. Materials and Methods: Between February 2002 and June 2004, 34 patients with localized prostate cancer with only one risk factor (Gleason score {>=}7, Clinical Stage [cT] {>=}2c, or prostate-specific antigen [PSA] of 11-20 ng/mL) and without clinical evidence of lymph node metastases were treated with radical prostatectomy (RP) and intraoperative radiotherapy on the tumor bed. A dose-finding procedure based on the Fibonacci method was employed. Dose levels of 16, 18, and 20 Gy were selected, which are biologically equivalent to total doses of about 60-80 Gy administered with conventional fractionation, using an {alpha}/{beta} ratio value of 3. Results: At a median follow-up of 41 months, 24 (71%) patients were alive with an undetectable PSA value. No patients died from disease, whereas 2 patients died from other malignancies. Locoregional failures were detected in 3 (9%) patients, 2 in the prostate bed and 1 in the common iliac node chain outside the radiation field. A PSA rise without local or distant disease was observed in 7 (21%) cases. The overall 3-year biochemical progression-free survival rate was 77.3%. Conclusions: Our dose-finding study demonstrated the feasibility of intraoperative radiotherapy in prostate cancer also at the highest administered dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-G-BRA-05: Predicting Volume Change of the Tumor and Critical Structures Throughout Radiation Therapy by CT-CBCT Registration with Local Intensity Correction

Purpose: The purpose of this study is to develop an accurate and effective technique to predict and monitor volume changes of the tumor and organs at risk (OARs) from daily cone-beam CTs (CBCTs). Methods: While CBCT is typically used to minimize the patient setup error, its poor image quality impedes accurate monitoring of daily anatomical changes in radiotherapy. Reconstruction artifacts in CBCT often cause undesirable errors in registration-based contour propagation from the planning CT, a conventional way to estimate anatomical changes. To improve the registration and segmentation accuracy, we developed a new deformable image registration (DIR) that iteratively corrects CBCT intensities using slice-based histogram matching during the registration process. Three popular DIR algorithms (hierarchical B-spline, demons, optical flow) augmented by the intensity correction were implemented on a graphics processing unit for efficient computation, and their performances were evaluated on six head and neck (HN) cancer cases. Four trained scientists manually contoured nodal gross tumor volume (GTV) on the planning CT and every other fraction CBCTs for each case, to which the propagated GTV contours by DIR were compared. The performance was also compared with commercial software, VelocityAI (Varian Medical Systems Inc.). Results: Manual contouring showed significant variations, [-76, +141]% from the mean of all four sets of contours. The volume differences (mean±std in cc) between the average manual segmentation and four automatic segmentations are 3.70±2.30(B-spline), 1.25±1.78(demons), 0.93±1.14(optical flow), and 4.39±3.86 (VelocityAI). In comparison to the average volume of the manual segmentations, the proposed approach significantly reduced the estimation error by 9%(B-spline), 38%(demons), and 51%(optical flow) over the conventional mutual information based method (VelocityAI). Conclusion: The proposed CT-CBCT registration with local CBCT intensity correction can accurately predict the tumor volume change with reduced errors. Although demonstrated only on HN nodal GTVs, the results imply improved accuracy for other critical structures. This work was supported by NIH/NCI under grant R42CA137886.

60 APPLIED LIFE SCIENCES↗

MRI of Acute Abdominal and Pelvic Non-obstetric Conditions in Pregnancy

Purpose of Review: The evaluation of abdominal and pelvic pain in the pregnant patient presents unique challenges due to altered physiology and implications of radiation exposure on the fetus. In many instances, a radiologist must consider the potential risk of fetal injury from ionizing radiation and maintaining diagnostic quality imaging. This article will focus on the role of MR imaging and its applications in a variety of acute abdomen and pelvic non-obstetric conditions potentially affecting the pregnant patient. Recent Findings: Non-contrast MR imaging is routinely employed in the presence of an initial equivocal ultrasound. However, MR is playing an increasingly more important role in the imaging of the pregnant patient, potentially surpassing the utility of conventional imaging techniques. Summary: As radiologists become more comfortable interpretating abdominal and pelvic MRI, MR will play a bigger role in imaging the pregnant patient in the emergency room, in the years to come.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A modified Stillinger-Weber potential for TlBr and its polymorphic extension

TlBr is promising for g- and x- radiation detection, but suffers from rapid performance degradation under the operating external electric fields. To enable molecular dynamics (MD) studies of this degradation, we have developed a Stillinger-Weber type of TlBr interatomic potential. During this process, we have also addressed two problems of wider interests. First, the conventional Stillinger-Weber potential format is only applicable for tetrahedral structures (e.g., diamond-cubic, zinc-blende, or wurtzite). Here we have modified the analytical functions of the Stillinger-Weber potential so that it can now be used for other crystal structures. Second, past modifications of interatomic potentials cannot always be applied by a broad community because any new analytical functions of the potential would require corresponding changes in the molecular dynamics codes. Here we have developed a polymorphic potential model that simultaneously incorporates Stillinger-Weber, Tersoff, embedded-atom method, and any variations (i.e., modified functions) of these potentials. As a result, we have implemented this polymorphic model in MD code LAMMPS, and demonstrated that our TlBr potential enables stable MD simulations under external electric fields.

36 MATERIALS SCIENCE↗