Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Towards Content Authenticity: Multimodal Fake News Detection and AI-Generated Text Identification

In today’s digital world, the spread of fake news and the rise of AI-generated text have become major threats to content authenticity and public trust. This thesis addresses both challenges through two complementary research directions: detecting fake news using multimodal features, and identifying AI-generated text using semantic and structural reasoning. The first part of the work focuses on fake news detection by introducing a novel model that combines text and image features through a unique rotational attention mechanism. Unlike traditional attention methods, this approach rotates the roles of query, key, and value across modalities to capture deeper interactions. Additionally, the model incorporates external domain information by linking news posts to top-ranked websites from Google search results, which helps assess the credibility of content based on its broader web context. This results in a more reliable and accurate fake news detection system that outperforms existing state-of-the-art methods. The second part presents SGG-ATD, a new framework for detecting AI-generated text. It uses masked language modeling to measure sentence coherence, followed by constructing a graph where keywords—both original and predicted—are connected based on semantic and contextual similarity. A Graph Convolutional Network (GCN) is then used to learn structural relationships within the text for final classification. Experimental results demonstrate that SGG-ATD achieves high F1-scores and consistently outperforms strong baselines. This method contributes to robust AI text detection, supporting accountability and resilience against AI-driven misinformation.

Gupta, Nidhi↗

A Dynamic Hierarchical Attention Framework for Multimodal Malware Detection

The increasing use of Android in the worldwide mobile ecosystem has come along with a significant increase in advanced malware, highlighting the critical necessity for efficient, scalable, and adaptable detection systems. Despite recent advancements in machine learning improving malware detection, the majority of current solutions are limited to one, two, or three data modalities, hence neglecting the comprehensive behavioral spectrum of contemporary multi-vector threats. This thesis presents the first comprehensive multimodal framework for Android malware detection, which combines textual, time-series (temporal), graph-based (structural), and visual information using an innovative hierarchical attention mechanism and Dynamic Fusion Controller (DFC). Our methodology consistently classifies and processes modalities as either sequential or structural, facilitating content-adaptive weighting and resilient cross-modal representation learning. We advance the implementation of cutting-edge time series techniques, such as MiniRocket, for malware detection, hence creating new opportunities for temporal analysis in cybersecurity. Comprehensive experimental assessment shows that our framework performs exceptionally well, with 99.46% classification accuracy and 97.15% detection accuracy, significantly outperforming existing approaches through effective multimodal integration and hierarchical attention mechanisms.

Nazmin, Tamanna↗

SQuaD: Smart Quantum Detection for Photon Recognition and Dark Count Elimination

Quantum detectors of single photons are an essential component for quantum information processing across computing, communication and networking. Today's quantum detection system, which consists of single photon detectors, timing electronics, control and data processing software, is primarily used for counting the number of single photon detection events. However, it is largely incapable of extracting other rich physical characteristics of the detected photons, such as their wavelengths, polarization states, photon numbers, or temporal waveforms. This work, for the first time, demonstrates a smart quantum detection system, SQuaD, which integrates a field programmable gate array (FPGA) with a neural network model, and is designed to recognize the features of photons and to eliminate detector dark-count. The SQuaD is a fully integrated quantum system with high timing-resolution data acquisition, onboard multi-scale data analysis, intelligent feature recognition and extraction, and feedback-driven system control. Our \name experimentally demonstrates 1) reliable photon counting on par with the state-of-the art commercial systems; 2) high-throughput data processing for each individual detection events; 3) efficient dark count recognition and elimination; 4) up to 100% accurate feature recognition of photon wavelength and polarization. Additionally, we deploy the SQuaD to an atomic (erbium ion) photon emitter source to realize noise-free control and readout of a spin qubit in the telecom band, enabling critical advances in quantum networks and distributed quantum information processing.

Linne, Karl C. [U. Chicago (main)] (ORCID:00090009↗

Detecting Unclassified Electromagnetic Signals for Secure Wireless Communication Using Open Set Recognition

We developed multiple machine learning methods for the detection and classification of new wireless communication waveforms, which is critical for targeted attacks in wireless networks and electronic warfare. Our machine learning models are capable of dynamically detecting security threats in near real time through our advanced open set recognition (OSR) approach. This model has demonstrated significant improvements in the detection of unknown waveforms, thereby enhancing the security and reliability of mission critical communications. Our approach to detecting uncertain security threats is novel; we advanced OSR techniques by incorporating domain knowledge of wireless signals. Specifically, we combined time and frequency domain model features to enhance the model’s performance. Utilizing an OSR approach eliminates the need for training data to be distributed similarly to the deployment environment and removes the requirement for the training set to contains all possible threat classes. This is crucial because it is often infeasible to determine and characterize all potential security threats in advance. Our model were trained on simulated data, generated in partnership with the University at Albany, State of New York. The data set contained a diverse array of wireless signals, including those with additive white Gaussian noise and multipath signals, with and without line of sight. This comprehensive training set allowed us to optimize our models to detect unknown waveforms under various challenging scenarios, such as low signal-to-noise ratios. By training on various waveforms, varying signal-to-noise ratio, and different sample sizes under normal conditions, our models were fine tuned to perform effectively in challenging environments.

99 - GENERAL AND MISCELLANEOUS↗

Methods and systems for remote detection of gases

Novel systems and methods for remotely detecting at least one constituent of a gas via infrared detection are provided. A system includes at least one extended source of broadband infrared radiation and a spectrally sensitive receiver positioned remotely from the source. The source and the receiver are oriented such that a surface of the source is in the field of view of the receiver. The source includes a heating component thermally coupled to the surface, and the heating component is configured to heat the surface to a temperature above ambient temperature. The receiver is operable to collect spectral infrared absorption data representative of a gas present between the source and the receiver. The invention advantageously overcomes significant difficulties associated with active infrared detection techniques known in the art, and provides an infrared detection technique with a much greater sensitivity than passive infrared detection techniques known in the art.

Johnson, Timothy J↗

Using Electronic Neutron Generators in Active Interrogation to Detect Shielded Fissionable Material

Experiments have been performed at Idaho National Laboratory to study methodology and instrumentation for performing neutron active interrogation die-away analyses for the purpose of detecting shielded fissionable material. Here we report initial work using a portable DT electronic neutron generator with a He-3 fast neutron detector to detect shielded fissionable material including >2 kg quantities of enriched uranium and plutonium. Measurements have been taken of bare material as well as of material hidden within a large plywood cube. Results from this work have demonstrated the efficacy of the die-away neutron measurement technique for quickly detecting the presence of special nuclear material hidden within plywood shields by analyzing the time dependent neutron signals in-between neutron generator pulses. Using a DT electronic neutron generator operating at 300 Hz with a yield of approximately 0.36 x 10**8 neutrons per second, 2.2 kg of enriched uranium hidden within a 0.60 m x 0.60 m x 0.70 m volume of plywood was positively detected with a measurement signal 2-sigma above the passive background within 1 second. Similarly, for a 500 second measurement period a lower detection limit of approaching the gram level could be expected with the same simple set-up.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectral analysis method for detecting an element

A method for detecting an element is described and which includes the steps of providing a gamma-ray spectrum which has a region of interest which corresponds with a small amount of an element to be detected; providing nonparametric assumptions about a shape of the gamma-ray spectrum in the region of interest, and which would indicate the presence of the element to be detected; and applying a statistical test to the shape of the gamma-ray spectrum based upon the nonparametric assumptions to detect the small amount of the element to be detected.

47 OTHER INSTRUMENTATION↗

Cyber-Physical Trade-Offs in Distributed Detection Networks

We consider a network of sensors that measure the scalar intensity due to the background or a source combined with background, inside a two-dimensional monitoring area. The sensor measurements may be random due to the underlying nature of the source and background or due to sensor errors or both. The detection problem is infer the presence of a source of unknown intensity and location based on sensor measurements. In the conventional approach, detection decisions are made at the individual sensors, which are then combined at the fusion center, for example using the majority rule. With increased communication and computation costs, we show that a more complex fusion algorithm based on measurements achieves better detection performance under smooth and non-smooth source intensity functions, Lipschitz conditions on probability ratios and a minimum packing number for the state-space. We show that these conditions for trade-offs between the cyber costs and physical detection performance are applicable for two detection problems: (i) point radiation sources amidst background radiation, and (ii) sources and background with Gaussian distributions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of machine learning models with domain experts for automated sensor selection for energy fault detection

Data-driven techniques that extract insights from sensor data reduce the cost of improving system energy performance through fault detection and system health monitoring. To lower cost barriers to widespread deployment, a methodology is proposed that takes advantage of existing sensor data, encodes expert knowledge about the application system to create ‘virtual sensors’ and applies statistical and mathematical methods to reduce the time required for manual configurations. The approach combines sensor data points with encoded expert knowledge that is generic to the application system but independent of a particular deployment, thereby reducing the need to tailor to individual deployments. Additionally, this paper not only presents a method that detects faults from measured energy data, but also (1) describes an engagement method with experts in the energy system domain to identify data, (2) integrates domain knowledge with the data, (3) automatically selects from among the large pool of potential input data, and (4) uses machine learning to automatically build a data-driven fault detection model. Demonstration on a commercial building chiller plant shows that only a small number of virtual sensors is necessary for fault detection with high accuracy rates. This corresponds to the use of only five out of 52 original sensor data points features. With as few as four features, classification F1 scores exceed 90% on the training set and 80% on the testing set. The results are implementable and realizable using off-the-shelf tools. The goal is to design with domain experts an energy monitoring system that can be configured once and then widely deployed with little additional cost or effort.

47 OTHER INSTRUMENTATION↗

Neutron Detection Alternatives to 3He for National Security Applications

One of the main uses for 3He is in gas proportional counters for neutron detection. Large radiation detection systems deployed for homeland security and proliferation detection applications use such systems. Due to the large increase in use of 3He for homeland security and basic research, the supply has dwindled, and can no longer meet the demand. This has led to the search for an alternative technology to replace the use of 3He-based neutron detectors. In this paper, we review the testing of currently commercially available alternative technologies for neutron detection in large systems used in various national security applications.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Validation of gamma-ray detection techniques for safeguards monitoring at natural uranium conversion facilities

Recent IAEA circulars and policy papers have sought to implement safeguards when any purified aqueous uranium solution or uranium oxides suitable for isotopic enrichment or fuel fabrication exists. Under the revised policy, IAEA Policy Paper 18, the starting point for nuclear material under safeguards was reinterpreted, suggesting that purified uranium compounds should be subject to safeguards procedures no later than the first point in the conversion process. In response to this technical need, a combination of simulation models and experimental measurements were employed to develop and validate concepts of nondestructive assay monitoring systems in a natural uranium conversion plant (NUCP). In particular, uranyl nitrate (UO 2 (NO 3 ) 2 ) solution exiting solvent extraction was identified as a key measurement point (KMP), where gamma-ray spectroscopy was selected as the process monitoring tool. The Uranyl Nitrate Calibration Loop Equipment (UNCLE) facility at Oak Ridge National Laboratory was employed to simulate the full-scale operating conditions of a purified uranium-bearing aqueous stream exiting the solvent extraction process in an NUCP. Nondestructive assay techniques using gamma-ray spectroscopy were evaluated to determine their viability as a technical means for drawing safeguards conclusions at NUCPs, and if the IAEA detection requirements of 1 significant quantity (SQ) can be met in a timely way. This work investigated gamma-ray signatures of uranyl nitrate circulating in the UNCLE facility and evaluated various gamma-ray detector sensitivities to uranyl nitrate. These detector validation activities include assessing detector responses to the uranyl nitrate gamma-ray signatures for spectrometers based on sodium iodide, lanthanum bromide, and high-purity germanium detectors. The results of measurements under static and dynamic operating conditions at concentrations ranging from 10–90 g U/L of natural uranyl nitrate are presented. A range of gamma-ray lines is examined, including attenuation for transmission measurement of density and concentration. It was determined that transmission-corrected gamma-ray spectra provide a reliable way to monitor the 235 U concentration of uranyl nitrate solution in transfer pipes in NUCPs. Furthermore, existing predictive and analysis methods are adequate to design and realize practical designs. The 137 Cs transmission source employed in this work is viable but not optimal for 235 U densitometry determination. Validated simulations assessed the viability of 133 Ba and 57Co as alternative densitometry sources. All three gamma-ray detectors are viable for monitoring natural uranium feed; although high-purity germanium is easiest to interpret, it is, however, the least attractive as an installation instrument. Overall, for monitoring throughput in a facility such as UNCLE, emulating the uranium concentration and pump speeds of the Springfields conversion facility in the United Kingdom, an uncertainty of less than 0.17% is required in order to detect the diversion of 1 SQ of uranyl nitrate through changes in uranium concentration over an accountancy period of one year with a detection probability of 50%. As a result, calibrated gamma-ray detection systems are capable of determining the concentration of uranium content in NUCPs, it is only in combination with verifiable operator declarations and supporting data, such as flow rate and enrichment, that safeguards conclusions can be drawn.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A reversible time-of-flight detector for use in pseudocontinuous resonance enhanced multiphoton (pc-REMPI) detection

A time-of-flight coincidence detector is demonstrated. This detector is optimized for use in a pseudocontinuous resonance enhanced multiphoton ionization scheme that requires photoelectrons and photoions to be detected in coincidence. The detector utilizes two simultaneously operating charged particle detectors, one for the detection of electrons and the other for the detection of ions. In order to allow for field reversal, the detectors are physically identical, differing only by the value of applied voltages. Particular attention is given to the implementation of a charge-to-voltage transducer that allows for subnanosecond detection of both electrons and ions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and Testing of an Air Fluorescence Imaging System for the Detection of Radiological Contamination

Detection of radionuclides emitting short-range radiation, such as {alpha} and low-energy {beta} particles, has always presented a challenge, particularly when such radionuclides are dispersed over a wide area. In this situation, conventional detection methods require the area of interest to be surveyed using a fragile probe at very close range--a slow, error-prone, and potentially dangerous process that may take many hours for a single room. The instrument under development uses a novel approach by imaging radiation-induced fluorescence in the air surrounding a contaminated area, rather than detecting the radiation directly. A robust and portable system has been designed and built that will allow contaminated areas to be rapidly detected and delineated. The detector incorporates position-sensitive photo-multiplier tubes, UV filters, a fast electronic shutter and an aspherical phase mask that significantly increases the depth-of-field. Preliminary tests have been conducted using sealed {sup 241}Am sources of varying activities and surface areas. The details of the instrument design will be described and the results of recent testing will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stringy WIMP detection and annihilation

We calculate the direct dark matter detection spin-independent and proton spin-dependent cross sections for a semirealistic intersecting D6-brane model. The cross sections are compared to the latest constraints of the current dark matter direct detection experiments, as well as the projected results of future dark matter experiments. The allowed parameter space of the intersecting D6-brane model is shown with all current experimental constraints, including those regions satisfying the WMAP and supercritical string cosmology limits on the dark matter density in the Universe. Additionally, we compute the indirect detection gamma-ray flux resulting from neutralino annihilation for the D6-brane model and compare the flux to the projected sensitivity of the Fermi Gamma-ray Space Telescope. Finally, we compute the direct and indirect detection cross sections as well as the gamma-ray flux resulting from weakly interacting massive particle annihilations for the one-parameter model for comparison, where the one-parameter model is a highly constrained subset of the minimal supergravity parameter space such that the soft-supersymmetry-breaking terms are functions of the common gaugino mass, which is common to many string compactifications.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Prospects for indirect detection of sneutrino dark matter with IceCube

We investigate the prospects for indirect detection of right-handed sneutrino dark matter at the IceCube neutrino telescope in a U(1){sub B-L} extension of the minimal supersymmetric standard model. The capture and annihilation of sneutrinos inside the Sun reach equilibrium, and the flux of produced neutrinos is governed by the sneutrino-proton elastic scattering cross section, which has an upper bound of 8x10{sup -9} pb from the Z{sup '} mass limits in the B-L model. Despite the absence of any spin-dependent contribution, the muon event rates predicted by this model can be detected at IceCube since sneutrinos mainly annihilate into leptonic final states by virtue of the fermion B-L charges. These subsequently decay to neutrinos with 100% efficiency. The Earth muon event rates are too small to be detected for the standard halo model irrespective of an enhanced sneutrino annihilation cross section that can explain the recent PAMELA data. For modified velocity distributions, the Earth muon events increase substantially and can be greater than the IceCube detection threshold of 12 events km{sup -2} yr{sup -1}. However, this only leads to a mild increase of about 30% for the Sun muon events. The number of muon events from the Sun can be as large as roughly 100 events km{sup -2} yr{sup -1} for this model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ODDS: Real-Time Object Detection Using Depth Sensors on Embedded GPUs

Detecting objects that are carried when someone enters or exits a room is very useful for a wide range of smart building applications including safety, security, and energy efficiency. While there has been a significant amount of work on object recognition using large-scale RGB image datasets, RGB cameras are too privacy invasive in many smart building applications and they work poorly in the dark. Additionally, deep object detection networks require powerful and expensive GPUs. We propose a novel system that we call ODDS (Object Detector using a Depth Sensor) that can detect objects in real-time using only raw depth data on an embedded GPU, e.g., NVIDIA Jetson TX1. Hence, our solution is significantly less privacy invasive (even if the sensor is compromised) and less expensive, while maintaining a comparable accuracy with state of the art solutions. Specifically, we resort to training a deep convolutional neural network using raw depth images, with curriculum based learning to improve accuracy by considering the complexity and imbalance in object classes and developing a sparse coding based technique that speeds up the system ~2× with minimal loss of accuracy. Based on a complete implementation and real-world evaluation, we see ODDS achieve 80.14% mean average precision in object detection in real-time (5-6 FPS) on a Jetson TX1.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Modeling Ambient Background in Complex Detection Scenarios

Radiation detection instrumentation is being widely deployed as a countermeasure against the movement and use of radiological dispersal devices and nuclear weapons. Accurate ambient background modeling is critical for accurate simulation of detection scenarios of interest; these background source terms influence minimum detectable limits and are thus a significant factor in overall system performance. Described below are the methods used to characterize ambient background source terms in the at-sea maritime cargo container environment, how statistical distributions on those source terms are defined, and how the resulting radiation fields are calibrated using available measurement data from aboard large ocean-going ships. Although the maritime environment is the demonstration case study, these methods are broadly applicable to modeling of all complex detection scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Real-Time, Adaptive Radiological Anomaly Detection and Isotope Identification Using Non-Negative Matrix Factorization

Spectroscopic anomaly detection and isotope identification algorithms are integral components in nuclear nonproliferation applications such as search operations. The task is especially challenging in the case of mobile detector systems because the observed gamma-ray background changes more than for a static detector system, and a pretrained background model can easily find itself out of domain. The result is that algorithms may exceed their intended false alarm rate or sacrifice detection sensitivity to maintain the desired false alarm rate. Non-negative matrix factorization (NMF) is a powerful tool for spectral anomaly detection and identification, but, like many similar algorithms that rely on data-driven background models, in its conventional implementation, it is unable to update in real time to account for environmental changes that affect the background spectroscopic signature. Here, we have developed a novel NMF-based algorithm that periodically updates its background model to accommodate changing environmental conditions. The adaptive NMF algorithm involves fewer assumptions about its environment, making it more generalizable than existing NMF-based methods while maintaining or exceeding detection performance on simulated and real-world datasets.

Anomaly detection↗