Theory and Experiments on Supersonic Air-to-Air Ejectors.

A comparison of experiment with theory is made for air ejectors having cylindrical mixing sections and operating under conditions of supersonic primary flow and either mixed or supersonic regimes of mixing. The effect on ejector performance of such parameters as mixer length and cross section, terminating diffuser, primary Mach number, and primary nozzle position is presented in terms of mass flow and pressure ratio.

Fabri, J↗

A cubic spline approximation for problems in fluid mechanics

A cubic spline approximation is presented which is suited for many fluid-mechanics problems. This procedure provides a high degree of accuracy, even with a nonuniform mesh, and leads to an accurate treatment of derivative boundary conditions. The truncation errors and stability limitations of several implicit and explicit integration schemes are presented. For two-dimensional flows, a spline-alternating-direction-implicit method is evaluated. The spline procedure is assessed, and results are presented for the one-dimensional nonlinear Burgers' equation, as well as the two-dimensional diffusion equation and the vorticity-stream function system describing the viscous flow in a driven cavity. Comparisons are made with analytic solutions for the first two problems and with finite-difference calculations for the cavity flow.

Rubin, S. G.↗

Effect of area ratio on the performance of a 5.5:1 pressure ratio centrifugal impeller

A centrifugal impeller which was initially designed for a pressure ratio of approximately 5.5 and a mass flow rate of 0.959 kg/sec was tested with a vaneless diffuser for a range of design point impeller area ratios from 2.322 to 2.945. The impeller area ratio was changed by successively cutting back the impeller exit axial width from an initial value of 7.57 mm to a final value of 5.97 mm. In all, four separate area ratios were tested. For each area ratio a series of impeller exit axial clearances was also tested. Test results are based on impeller exit surveys of total pressure, total temperature, and flow angle at a radius 1.115 times the impeller exit radius. Results of the tests at design speed, peak efficiency, and an exit tip clearance of 8 percent of exit blade height show that the impeller equivalent pressure recovery coefficient peaked at a design point area ratio of approximately 2.748 while the impeller aerodynamic efficiency peaked at a lower value of area ratio of approximately 2.55. The variation of impeller efficiency with clearance showed expected trends with a loss of approximately 0.4 points in impeller efficiency for each percent increase in exit axial tip clearance for all impellers tested.

Schumann, L. F.↗

Effect of area ratio on the performance of a 5.5:1 pressure ratio centrifugal impeller

A centrifugal impeller which was initially designed for a pressure ratio of approximately 5.5 and a mass flow rate of 0.959 kg/sec was tested with a vaneless diffuser for a range of design point impeller area ratios from 2.322 to 2.945. The impeller area ratio was changed by successively cutting back the impeller exit axial width from an initial value of 7.57 mm to a final value of 5.97 mm. In all, four separate area ratios were tested. For each area ratio a series of impeller exit axial clearances was also tested. Test results are based on impeller exit surveys of total pressure, total temperature, and flow angle at a radius 1.115 times the impeller exit radius. Results of the tests at design speed, peak efficiency, and an exit tip clearance of 8 percent of exit blade height show that the impeller equivalent pressure recovery coefficient peaked at a design point area ratio of approximately 2.748 while the impeller aerodynamic efficiency peaked at a lower value of area ratio of approximately 2.55. The variation of impeller efficiency with clearance showed expected trends with a loss of approximately 0.4 points in impeller efficiency for each percent increase in exit axial tip clearance for all impellers tested.

Schumann, L. F.↗

A Particle-Based Conditional Sampling Scheme for the Simulation of Transport in Fractured Rock With Diffusion Into Stagnant Water and Rock Matrix

In situ experiments and field-scale characterization studies have pointed out that, in fractured crystalline media, groundwater flow is highly channelized. This implies that, at the scale of a single fracture, only part of the fracture surface area is in contact with flowing water, while the rest of in-plane water is essentially stagnant and can be accessed by solutes via molecular diffusion. Despite their importance for contaminant retention, to date, there are no numerical or analytical approaches that could be used to assess the implication of stagnant water zones on solute transport in realistic large-scale Discrete Fracture Network-based models. In this study, we present an efficient and flexible algorithm for the simulation of transport in fractured rock with diffusion into stagnant water and rock matrix. The algorithm is a generalization of a previously developed numerical framework for time domain particle tracking in sparsely fractured rock. The key of the generalization is that total time in fracture (τ f ) is first evaluated using a Monte Carlo sampling and then a second sampling is performed conditioned on τ f . The algorithm has been successfully validated against existing independent solutions and the implication of diffusion into stagnant water and secondary diffusion into the matrix has been assessed for a realistic modeling scenario. The results show that, due to diffusion into stagnant water, contaminants are more strongly retarded. This increased retention is more significant for sorbing species, as a larger number of sorption sites is accessible. A high sensitivity to the flowing channel/stagnant water zone geometry has also been observed.

54 ENVIRONMENTAL SCIENCES↗

Improvement of the second- and third-moment modeling of turbulence: A study of Reynolds-stress closure model

Four parts of the Reynolds-stress closure modeling are reported: (1) improvement of the k and epsilon equaitons; (2) development of the third-moment transport equation; (3) formulation of the diffusion coefficient of the momentum equation by using the algebraic-stress model of turbulence; and (4) the application of the Reynolds-stress model to a heat exchanger problem. It was demonstrated that the third-moment transport model improved the prediction of the triple-velocity products in the recirculating and reattaching flow regions in comparison with the existing algebraic models for the triple-velocity products. Optimum values for empirical coefficients are obtained for the prediction of the backward-facing step flows. A functional expression is derived for the coefficient of the momentum diffusion by employing the algebraic-stress model. The second-moment closure is applied to a heat transfer problem. The computations for the flow in a corrugated-wall channel show that the second-moment closure improves the prediction of the heat transfer rates by 30% over the k - epsilon model.

Amano, R. S.↗

Numerical simulation of the hydrodynamical combustion to strange quark matter

We present results from a numerical solution to the burning of neutron matter inside a cold neutron star into stable u,d,s quark matter. Our method solves hydrodynamical flow equations in one dimension with neutrino emission from weak equilibrating reactions, and strange quark diffusion across the burning front. We also include entropy change from heat released in forming the stable quark phase. Our numerical results suggest burning front laminar speeds of 0.002-0.04 times the speed of light, much faster than previous estimates derived using only a reactive-diffusive description. Analytic solutions to hydrodynamical jump conditions with a temperature-dependent equation of state agree very well with our numerical findings for fluid velocities. The most important effect of neutrino cooling is that the conversion front stalls at lower density (below {approx_equal}2 times saturation density). In a two-dimensional setting, such rapid speeds and neutrino cooling may allow for a flame wrinkle instability to develop, possibly leading to detonation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Density Effects on Lock Exchange Flow During a DCC

The High Temperature Test Facility (HTTF) is a scaled, electric model at Oregon State University (OSU) of the Modular High Temperature Gas Reactor (MHTGR) by General Atomics. There are a few major differences between the design and the OSU facility. In the HTTF the reactor pressure vessel and the reactor cavity are in two separate tanks connected by a crossover duct similar to the crossover duct that would be seen between the reactor core and the steam generator in the MHTGR. This feature allows for the facility to open two main break valves simulating a Double-Ended Guillotine Break (DEGB) of the cross over duct, synonymous to a crossover duct break in the MHTGR. The density gradient driven flow phenomena in the HTTF duct can then be studied further. This break would cause a depressurization of the reactor and a loss of flow. It is called the Depressurized Loss of Forced Convection Accident (D-LOFC), also known as the Depressurized Conduction Cool-Down Event for High Temperature Gas Reactors (HTGRs) because heat removal is by conduction through the core and radiation out of the vessel. The HTTF was built and scaled to maintain the highest accuracy for the DCC. Prototypical temperatures with an inlet temperature of 259 deg. C and an outlet temperature of 687 deg. C are maintained in the HTTF. The temperature profile is also maintained in the smaller volume by using a ceramic core. The HTTF uses graphite heaters because the resistive heat produced does not change significantly with temperature . In order to produce a facility of similar temperatures within the allotted budget, sacrifices had to be made in other areas. The HTTF is scaled one-fourth in diameter, one-fourth in height and one-eighth in pressure of the MHTGR. There are also a few limitations for the HTTF. While in the MHTGR, the cavity is filled with air, the HTTF uses highly pure Nitrogen and does not have the ability to simulate a full depressurization. The DCC event is traditionally comprised of multiple stages: depressurization, molecular diffusion and natural circulation. However, this traditional interpretation ignores lock exchange flow which will occur immediately following depressurization and could have significant consequences in the reactor. It was found that the traditional model underestimates the amount of air ingress by at least 660 times according to Oh and Kim in their theoretical research of air ingress. Molecular diffusion also decreases with stratification. Any model that specifies the gases are stratified has further underestimated the air ingress of the DCC event. In addition, molecular diffusion is a much slower process, allowing the reactor to shut down and cool off considerably from operating temperatures. Thus, understanding lock exchange flow, the air ingress concentrations and the time scale is critical to MHTGR research and licensing. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Two-dimensional viscous flow simulation of a shock accelerated heavy gas cylinder

Numerical simulation of Richtmyer–Meshkov instability (RMI) is conducted using an improved localized artificial diffusivity (LAD) approach, which is used to treat discontinuities in the form of material interfaces and shocks in the flow-field. The RMI occurs on a cylindrical interface between air and SF 6 accelerated by a Mach 1.2 shock initially in air. Navier–Stokes simulation is conducted to accurately predict the mixing between the two fluids. The beginning conditions for the two-dimensional simulations are matched to previous experimental work by C. Tomkins et al. [“An experimental investigation of mixing mechanisms in shock-accelerated flow,” J. Fluid Mech. 611, 131 (2008)] and good agreement is found between the experimental data and numerical results. The study on initial condition sensitivity indicates that the initial pressure and density gradient are critical parameters that determine the primary vortex generation responsible for the flow development. A grid convergence study is carried out and the relative contribution of the artificial properties introduced by the LAD method is characterized. Novel to this study is the exploration of the effect of the third species (acetone used as a tracer particle in the experiments to obtain contour fields using planar laser induced florescence). The effect of the presence of the third species on the evolution of the RMI and mixing is shown to be non-negligible and an estimate of the amount of the tracer species that was present in the initial experimental set-up is given.

42 ENGINEERING↗

Viscous flow solutions with a cubic spline approximation

A cubic spline approximation is used for the solution of several problems in fluid mechanics. This procedure provides a high degree of accuracy even with a nonuniform mesh, and leads to a more accurate treatment of derivative boundary conditions. The truncation errors and stability limitations of several typical integration schemes are presented. For two-dimensional flows a spline-alternating-direction-implicit (SADI) method is evaluated. The spline procedure is assessed and results are presented for the one-dimensional nonlinear Burgers' equation, as well as the two-dimensional diffusion equation and the vorticity-stream function system describing the viscous flow in a driven cavity. Comparisons are made with analytic solutions for the first two problems and with finite-difference calculations for the cavity flow.

Rubin, S. G.↗

The aerodynamic effect of fillet radius in a low speed compressor cascade

The aerodynamic effects of fillet size in a low speed compressor cascade were experimentally studied. Two blade profiles were used during the experiment, namely a controlled diffusion blade and a double circular arc blade. Cascades were tested with three fillet radii and two boundary layer thicknesses over a large range of incidence angles. The cascade performance was determined by extensive downstream flow measurements using a two head, 5 hole pressure probe. Results differ significantly between the two types of blades tested. As fillet radius increases secondary flows and total pressure losses were found to increase for the controlled diffusion blades; whereas, for the double circular arc blades the losses decrease, particularly at high incidence angles.

Curlett, Brian P.↗

Improved numerical methods for turbulent viscous recirculating flows

The hybrid-upwind finite difference schemes employed in generally available combustor codes possess excessive numerical diffusion errors which preclude accurate quantative calculations. The present study has as its primary objective the identification and assessment of an improved solution algorithm as well as discretization schemes applicable to analysis of turbulent viscous recirculating flows. The assessment is carried out primarily in two dimensional/axisymetric geometries with a view to identifying an appropriate technique to be incorporated in a three-dimensional code.

Turan, A.↗

Modeling electrokinetic flows by consistent implicit incompressible smoothed particle hydrodynamics

We present an efficient implicit incompressible smoothed particle hydrodynamics (I2SPH) discretization of Navier-Stokes, Poisson-Boltzmann, and advection-diffusion equations subject to Dirichlet or Robin boundary conditions. It is applied to model various two and three dimensional electrokinetic flows in simple or complex geometries. The I2SPH's accuracy and convergence are examined via comparison with analytical solutions, grid-based numerical solutions, or empirical models. The new method provides a framework to explore broader applications of SPH in microfluidics and complex fluids with charged objects, such as colloids and biomolecules, in arbitrary complex geometries.

Pan, Wenxiao↗

Wilson Corners SWMU 001 2015 Annual Long Term Monitoring Report Kennedy Space Center, Florida

This document presents the findings of the 2015 Long Term Monitoring (LTM) that was completed at the Wilson Corners site, located at the National Aeronautics and Space Administration John F. Kennedy Space Center, Florida. The objectives of the 2015 LTM event were to evaluate the groundwater flow direction and gradient, to monitor the vertical and horizontal extent of the volatile organic compounds (VOCs; including the upgradient and sidegradient extents, which are monitored every five years), and to monitor select locations internal to the dissolved groundwater plume. The 2015 LTM event included several upgradient and sidegradient monitoring wells that are not sampled annually to verify the extent of VOCs in this portion of the site. The December 2015 LTM groundwater sampling event included, depth to groundwater measurements, 40 VOC samples collected using passive diffusion bags, and one VOC sample collected using low-flow techniques. Additionally, monitoring well MW0052DD was overdrilled and abandoned using rotasonic drilling techniques. The following conclusions can be made based on the 2015 LTM results: groundwater flow is generally to the west with northwest and southwest flow components from the water table to approximately 55 feet below land surface (ft BLS); peripheral monitoring wells generally delineate VOCs to groundwater cleanup target levels (GCTLs) except for monitoring wells MW0088, MW0090, MW0095, and NPSHMW0039, which had vinyl chloride (VC) concentrations near the GCTL and MW0062, which had trichloroethene (TCE), cis-1,2-dichloroethenen (cDCE), and VC concentrations above natural attenuation default concentrations (NADCs); VOCs in interior downgradient wells generally fluctuate within historic ranges except for monitoring wells in the north-northwest portion of the site, which have increasing VC concentrations indicating potential plume migration and expansion; Historically, the vertical extents of the VOCs were delineated by monitoring wells screened greater than 60 ft BLS (MW0083 through MW0086, and MW0078). The 2015 LTM results indicate that concentrations of daughter product cDCE is greater than the NADC in MW0078 and that cDCE and VC are greater than NADCs in MW0130. TCE was greater than the GCTL in monitoring well MW130 and not detected above method detection limits (9 micrograms per Liter) in monitoring well MW0078. No GCTL exceedances were identified in monitoring wells MW0083 or MW0086; the dissolved plume footprint appears generally stable, though not fully delineated by monitoring well data in the northeast portion of the site; and 2015 LTM results generally support the existing Conceptual Site Model. Geosyntec recommends modifying the LTM program, collecting a verification sample from monitoring well MW0062, and performing a direct push technology instigation in the northnortheastern portion of the site. A cluster of monitoring wells (MW0132 [2 to 12 ft BLS], MW0133 [15 to 25 ft BLS], and MW0134 [29 to 34 ft BLS]) is proposed to delineate impacts in the northnortheast portion of the site. Geosyntec recommends installation of a vertical extent well in the center of the site (Hot Spot 2 area) post-remediation implementation.

groundwater↗

Thermal and solutal convection with conduction effects inside a rectangular enclosure

We numerically investigate the effects of various boundary conditions on the flow field characteristics of the physical vapor transport process. We use a prescribed temperature profile as boundary condition on the enclosure walls, and we consider parametric variations applicable to ground-based and space microgravity conditions. For ground-based applications, density gradients in the fluid phase generate buoyancy-driven convection which in turn disrupts the uniformity of the mass flux at the interface depending on the orientation. Heat conduction in the crystal can affect the fluid flow near the interface of the crystal. When considering isothermal source and sink at the interfaces, we observe a diffusive mode and three modes (i.e., thermal, solutal, and thermo-solutal). The convective modes show opposing flow field trends between thermal and solutal convection; theoretically, these trends can be used to achieve a uniform mass flux near the crystal. However, under the physical conditions chosen, the mathematical condition necessary for uniform mass flux cannot be satisfied because of thermodynamic restrictions. When a longitudinal thermal gradient is prescribed on the boundary of the crystal, a non-uniform interface temperature results, which induces a symmetrical fluid flow near the interface for the vertical case. For space microgravity applications, we show that the flow field is dominated by the Stefan wind and a uniform mass flux results at the interface.

Mennetrier, Christophe↗

Reduction of Altitude Diffuser Jet Noise Using Water Injection

A feasibility study on the effects of injecting water into the exhaust plume of an altitude rocket diffuser for the purpose of reducing the far-field acoustic noise has been performed. Water injection design parameters such as axial placement, angle of injection, diameter of injectors, and mass flow rate of water have been systematically varied during the operation of a subscale altitude test facility. The changes in acoustic far-field noise were measured with an array of free-field microphones in order to quantify the effects of the water injection on overall sound pressure level spectra and directivity. The results showed significant reductions in noise levels were possible with optimum conditions corresponding to water injection at or just upstream of the exit plane of the diffuser. Increasing the angle and mass flow rate of water injection also showed improvements in noise reduction. However, a limit on the maximum water flow rate existed as too large of flow rate could result in un-starting the supersonic diffuser.

Allgood, Daniel C.↗

Reduction of Altitude Diffuser Jet Noise Using Water Injection

A feasibility study on the effects of injecting water into the exhaust plume of an altitude rocket diffuser for the purpose of reducing the far-field acoustic noise has been performed. Water injection design parameters such as axial placement, angle of injection, diameter of injectors, and mass flow rate of water have been systematically varied during the operation of a subscale altitude test facility. The changes in acoustic far-field noise were measured with an array of free-field microphones in order to quantify the effects of the water injection on overall sound pressure level spectra and directivity. The results showed significant reductions in noise levels were possible with optimum conditions corresponding to water injection at or just upstream of the exit plane of the diffuser. Increasing the angle and mass flow rate of water injection also showed improvements in noise reduction. However, a limit on the maximum water flow rate existed as too large of flow rate could result in un-starting the supersonic diffuser.

Allgood, Daniel C.↗

Strain-induced extinction of hydrogen-air counterflow diffusion flames - Effects of steam, CO2, N2, and O2 additives to air

A fundamental study was performed using axisymmetric nozzle and tubular opposed jet burners to measure the effects of laminar plug flow and parabolic input velocity profiles on the extinction limits of H2-air counterflow diffusion flames. Extinction limits were quantified by 'flame strength', (average axial air jet velocity) at blowoff of the central flame. The effects of key air contaminants, on the extinction limits, are characterized and analyzed relative to utilization of combustion contaminated vitiated air in high enthalpy supersonic test facilities.