Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed training”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Examples of Use of SINBAD Database for Nuclear Data and Code Validation

Benchmark experiments can serve several purposes and the availability of suitable experimental data is fundamental to ensure that modelling tools meet the requirements of nuclear industry and licensing needs. Essentially, they are used for: - validation of nuclear cross-section data, - validation of nuclear codes and models used, - qualification and training of users through benchmarking and code comparison exercises. The Shielding Integral Benchmark Archive and Database (SINBAD) project was started in the early 1990's at the OECD Nuclear Energy Agency Data Bank (NEA DB) and the Radiation Safety Information Computational Center (RSICC) as a collection of quality experiments for validating and benchmarking computer codes and data for radiation transport and shielding applications. Currently, the SINBAD database comprises over 100 benchmark compilations and evaluations of relevance to: - reactor shielding, pressure vessel dosimetry (48); - fusion blanket neutronics (31); - accelerator shielding (23). In order to facilitate their use, the data are organized in the standardized format structure. The index and the master document (called abstract) use the Hyper Text Markup Language (HTML) format with links to text files, figures, Portable Document Format (pdf) documents and computer code inputs. The format allows easy access and forward/backward navigation among the data and has proved to be suitable, general enough and above all easy (and low-cost) to maintain. In addition to the characterization of the radiation source, description of the shielding set-up, the instrumentation and the relevant detector measurements, most sets in SINBAD contain also the deterministic or Monte Carlo radiation transport computer model used for the interpretation of the experiment and, where available, results from uncertainty analysis. The set of primary documents used for the benchmark compilation and evaluation are provided in computer readable form. The database is intended for different types of users, including nuclear data evaluators, computer code developers, experiment designers and university students. SINBAD is available from the NEA Data Bank and RSICC (see https://www.oecdnea.org/science/wprs/shielding/sinbad/). Up to now several hundreds of SINBAD packages were distributed from the NEA DB and RSICC. Since 2011 the maintenance and further development of the database is coordinated in the scope of the OECD NEA Nuclear Science Committee (NSC) Working Party on Scientific Issues of Reactor Systems (WPRS) Expert Group on Radiation Transport and Shielding (EGRTS). A key objective of the group is to identify, evaluate and preserve experimental data on shielding benchmarks. The Expert Group maintains close links with the International Reactor Physics Experiment Evaluation (IRPhE) and International Criticality Safety Benchmark Evaluation (ICSBEP) projects, as well as in co-ordination with the JEFF and EFF NEA Data Bank projects and with the SATIF community of accelerator shielding specialists. In the last years, much effort was devoted to the quality review of the available benchmark information.

42 ENGINEERING↗

Evaluation of cloud-resolving model simulations of midlatitude cirrus with ARM and A-train observations

Cirrus clouds are ubiquitous in the upper troposphere and still constitute one of the largest uncertainties in climate predictions. Our paper evaluates cloud-resolving model (CRM) and cloud system-resolving model (CSRM) simulations of a midlatitude cirrus case with comprehensive observations collected under the auspices of the Atmospheric Radiation Measurements (ARM) program and with spaceborne observations from the National Aeronautics and Space Administration A-train satellites. The CRM simulations are driven with periodic boundary conditions and ARM forcing data, whereas the CSRM simulations are driven by the ERA-Interim product. Vertical profiles of temperature, relative humidity, and wind speeds are reasonably well simulated by the CSRM and CRM, but there are remaining biases in the temperature, wind speeds, and relative humidity, which can be mitigated through nudging the model simulations toward the observed radiosonde profiles. Simulated vertical velocities are underestimated in all simulations except in the CRM simulations with grid spacings of 500 m or finer, which suggests that turbulent vertical air motions in cirrus clouds need to be parameterized in general circulation models and in CSRM simulations with horizontal grid spacings on the order of 1 km. The simulated ice water content and ice number concentrations agree with the observations in the CSRM but are underestimated in the CRM simulations. The underestimation of ice number concentrations is consistent with the overestimation of radar reflectivity in the CRM simulations and suggests that the model produces too many large ice particles especially toward the cloud base. Simulated cloud profiles are rather insensitive to perturbations in the initial conditions or the dimensionality of the model domain, but the treatment of the forcing data has a considerable effect on the outcome of the model simulations. Despite considerable progress in observations and microphysical parameterizations, simulating the microphysical, macrophysical, and radiative properties of cirrus remains challenging. Comparing model simulations with observations from multiple instruments and observational platforms is important for revealing model deficiencies and for providing rigorous benchmarks. But, there still is considerable need for reducing observational uncertainties and providing better observations especially for relative humidity and for the size distribution and chemical composition of aerosols in the upper troposphere.

54 ENVIRONMENTAL SCIENCES↗

Cyber risk assessment and investment optimization using game theory and ML-based anomaly detection and mitigation for wide-area control in smart grids

The electric power grid is increasingly becoming susceptible to cyber attacks that exploit vulnerabilities in the smart grid control, information, and physical layers. Successful cyber attacks can have catastrophic impacts on the social and economic well-being of any nation all over the globe. It has, thus, become imperative to secure the smart grid against such adversarial actions to ensure stable, secure, and reliable operation of the grid. The existing research and industry practices prove to be inadequate in terms of providing pragmatic and effective defense methodologies and measures for long-term cybersecurity planning and real-time cybersecurity for grid operation. For example, existing works lack models that incorporate uncertain behavior of cyber-attackers and pragmatic defense measures for cyber risk assessment and cybersecurity investment optimization which often provide unreliable and strictly qualitative solutions to these problems. At the same time, with the growing number of cyber incidents in the grid, there still exists a need to develop attack-resilient algorithms for wide-area monitoring, protection, and control (WAMPAC) applications like the wide-area voltage control systems (WAVCS) for Flexible AC Transmissions Systems (FACTS) that lack in scalable and feasible solutions from the cybersecurity perspective. This dissertation proposes novel models and methodologies for: (1) Cybersecurity planning, and (2) Cybersecurity for system operation. The cybersecurity planning is achieved through cyber risk assessment and cybersecurity resource investment optimization for long-term cybersecurity of the grid using game theory and attack-defense trees. Cybersecurity for system operation consists of development of cyber anomaly detection and mitigation algorithms for flexible AC transmission system (FACTS) controller-based wide-area voltage control systems (WAVCS) using machine learning (ML), and software defined networking-based moving target defense network routing for achieving real-time cyber-physical security for grid operations. This is followed by hardware-in-the-loop (HIL) implementation and evaluation of these attack prevention, detection, and mitigation algorithms and methodologies showcasing their feasibility in a close to real-world environment. For cybersecurity planning, a novel approach involving a combination of game theory and attack defense trees (ADT) for optimal cybersecurity resource allocation in the smart grid is proposed. This methodology involves modeling of the cyber-physical smart grid substations as ADTs, defining attacker costs, defense costs, and attack probabilities for attack access points. Using game theoretical formulation, optimal defense strategies for the defender of the system to invest cybersecurity resources in the grid are obtained. Additionally, a game-theoretic framework is developed for quantitative cyber-physical risk assessment of the grid under a dynamically changing cyber threat space and uncertain behavior of cyber attackers which is further used to optimize investments in the smart grid's cybersecurity resources. The attacker, defender, and the smart grid system are modeled while incorporating attacker-stochasticity and federal guidelines for smart grid cybersecurity. This allows quantification of threat, vulnerabilities, and attack impact of the grid for quantitative risk assessment. The defender's budget to invest in the security resources in the grid is optimized based on the strategies leading to minimum system risk. The evaluation of the proposed solutions highlight the feasibility for practical implementation of these methodologies and algorithms in the smart grid, while taking the federal requirements and guidelines for smart grid security into consideration. For achieving cybersecurity for system operation, attack prevention, detection, and mitigation algorithms and methodologies are developed specifically for FACTS-based WAVCS. Anomaly detection and mitigation in the WAVCS are achieved using algorithms based on machine learning which involves offline training and testing of ML models with CPS datasets incorporating physics-based features that allow accurate distinction between system faults and cyber attacks. For attack prevention, a methodology based on software defined network (SDN)-based moving target defense (MTD) network routing is proposed that enables prevention of Denial of Service (DoS) type attacks on the smart grid communication system. Subsequently, these methodologies and algorithms are implemented and evaluated on an HIL testbed that allows for real-time attack prevention, detection, and mitigation of emulated cyber attacks on the WAVCS in a close to real-world environment. The results show highly accurate and efficient performance of the implemented algorithms and methodologies with the smart grid system operating within the NERC's system operation limits even in the presence of DoS and data integrity cyber attacks. This work opens up future research opportunities in other directions such as (1) Expanding cybersecurity planning methodologies to real-time cyber contingency analysis with different game formulations; and (2) Applying the cybersecurity for system operation algorithms to broader categories of wide-area control applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Partitioning of Nanoparticles into Organic Phases and Model Cells

There is a recognized need to understand and predict the fate, transport and bioavailability of engineered nanoparticles (ENPs) in aquatic and soil ecosystems. Recent research focuses on either collection of empirical data (e.g., removal of a specific NP through water or soil matrices under variable experimental conditions) or precise NP characterization (e.g. size, degree of aggregation, morphology, zeta potential, purity, surface chemistry, and stability). However, it is almost impossible to transition from these precise measurements to models suitable to assess the NP behavior in the environment with complex and heterogeneous matrices. For decades, the USEPA has developed and applies basic partitioning parameters (e.g., octanol-water partition coefficients) and models (e.g., EPI Suite, ECOSAR) to predict the environmental fate, bioavailability, and toxicity of organic pollutants (e.g., pesticides, hydrocarbons, etc.). In this project we have investigated the hypothesis that NP partition coefficients between water and organic phases (octanol or lipid bilayer) is highly dependent on their physiochemical properties, aggregation, and presence of natural constituents in aquatic environments (salts, natural organic matter), which may impact their partitioning into biological matrices (bioaccumulation) and human exposure (bioavailability) as well as the eventual usage in modeling the fate and bioavailability of ENPs. In this report, we use the terminology "partitioning" to operationally define the fraction of ENPs distributed among different phases. The mechanisms leading to this partitioning probably involve both chemical force interactions (hydrophobic association, hydrogen bonding, ligand exchange, etc.) and physical forces that bring the ENPs in close contact with the phase interfaces (diffusion, electrostatic interactions, mixing turbulence, etc.). Our work focuses on partitioning, but also provides insight into the relative behavior of ENPs as either "more like dissolved substances" or "more like colloids" as the division between behaviors of macromolecules versus colloids remains ill-defined. Below we detail our work on two broadly defined objectives: (i) Partitioning of ENP into octanol, lipid bilayer, and water, and (ii) disruption of lipid bilayers by ENPs. We have found that the partitioning of NP reaches pseudo-equilibrium distributions between water and organic phases. The equilibrium partitioning most strongly depends on the particle surface charge, which leads us to the conclusion that electrostatic interactions are critical to understanding the fate of NP in the environment. We also show that the kinetic rate at which particle partition is a function of their size (small particles partition faster by number) as can be predicted from simple DLVO models. We have found that particle number density is the most effective dosimetry to present our results and provide quantitative comparison across experiments and experimental platforms. Cumulatively, our work shows that lipid bilayers are a more effective organic phase than octanol because of the definable surface area and ease of interpretation of the results. Our early comparison of NP partitioning between water and lipids suggest that this measurement can be predictive of bioaccumulation in aquatic organisms. We have shown that nanoparticle disrupt lipid bilayer membranes and detail how NP-bilayer interaction leads to the malfunction of lipid bilayers in regulating the fluxes of ionic charges and molecules. Our results show that the disruption of the lipid membranes is similar to that of toxin melittin, except single particles can disrupt a bilayer. We show that only a single particle is required to disrupt a 150 nm DOPC liposome. The equilibrium leakage of membranes is a function of the particle number density and particle surface charge, consistent with results from our partitioning experiments. Our disruption experiments with varying surface functionality show that positively charged particles (poly amine) are most disruptive, consistent with in in vitro toxicity panels using cell cultures. Overall, this project has resulted in 8 published or submitted archival papers and has been presented 12 times. We have trained five students and provided growth opportunities for a postdoc.

54 ENVIRONMENTAL SCIENCES↗

PowerModelsGAT-AI: Physics-Informed Graph Attention for Multi-System Power Flow With Continual Learning

Solving the alternating current power flow equations in real time is essential for secure grid operation, yet classical Newton–Raphson solvers can be slow under stressed conditions. Existing graph neural networks for power flow are typically trained on a single system and often degrade on different systems. We present PowerModelsGAT-AI, a physics-informed graph attention network that predicts bus voltages and generator injections. The model uses bus-type-aware masking to handle different bus types and balances multiple loss terms, including a power-mismatch penalty, using learned weights. We evaluate the model on 14 benchmark systems (4 to 6,470 buses) and train a unified model on 13 of these under contingency conditions with up to two branch outages, achieving an average normalized mean absolute error of 0.89% for voltage magnitudes and R 2 >0.99 for voltage angles. We also show continual learning: when adapting a base model to a new 1,354-bus system, standard fine-tuning causes severe forgetting with error increases exceeding 1000% on base systems, while our experience replay and elastic weight consolidation strategy keeps error increases below 2% and in some cases improves base-system performance. Interpretability analysis shows that learned attention weights correlate with physical branch parameters (susceptance: r=0.38 ; thermal limits: r=0.22 ), and feature importance analysis supports that the model captures established power flow relationships.

24 POWER TRANSMISSION AND DISTRIBUTION↗

MO-FG-303-02: BEST IN PHYSICS (THERAPY): Cherenkov Emission Dosimetry: Feasibility for Electron Radiotherapy

Purpose: To investigate from first principles, corroborated by Monte Carlo simulations and experimental measurements, the feasibility of developing a relative Cherenkov emission (CE) dosimetry protocol for electron beam radiotherapy. Methods: Monte Carlo (MC) simulations of mono-energetic electrons incident on water were carried out in Geant4. Percent depth Cherenkov emission (PDCE) and dose (PDD) distributions were scored for incidence energies of 4, 6, 9, 12, 15, and 18 MeV. PDCE-to-PDD analytical conversion models were developed from least-squares data fits generated for PDD as a function of PDCE at the same depth and at different depths. Experimental techniques for validation of these models are examined. Results: Same-depth PDD versus PDCE data fits indicate that although the relationship is linear to first order (correlation r > 0.9 for all energies), it is much more accurately approximated by separate linear and quadratic models for the build-up and drop-off regions, respectively (r > 0.999), which is theoretically underpinned. To understand the source of this relationship and its basis for developing robust conversion models, an approximate quadratic first-principles model was derived and found in agreement with MC/measured data (20% deviation at worst). Conversely, data fits of PDD versus different-depth PDCE unveiled a depth-invariant effective point of measurement of 1.5–2.1 mm downstream with 4–18 MeV incidence, respectively (r > 0.999 in the drop-off region). We present an analytical first-principles justification for this shift. This method led to errors of <1% in drop-off region PDD (<2% for PDD<20% with 4 MeV incidence) and <0.2 mm in practical range prediction. Conclusion: We present robust quantitative prediction models, derived from first-principles and supported by simulation and measurement, for relative dose from Cherenkov emission by high-energy electrons. This constitutes a major step towards development of protocols for routine clinical quality assurance as well as real-time in vivo Cherenkov dosimetry in radiotherapy. The authors acknowledge partial support by Fonds de recherche du Quebec - Nature et technologies (FRQNT), CREATE Medical Physics Research Training Network grant of the Natural Sciences and Engineering Research Council of Canada (NSERC), CREATE Integrated Sensor Systems grant of NSERC, the Canadian Institutes of Health Research (CIHR), and NSERC.

60 APPLIED LIFE SCIENCES↗

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid↗

Puerto Rico Grid Resilience and Transitions to 100% Renewable Energy Study (PR100): Six-Month Progress Update [Slides]

Puerto Rico has committed to meeting its electricity needs with 100% renewable energy by 2050, along with realizing interim goals of 40% by 2025, 60% by 2040, the phase-out of coal-fired generation by 2028, and a 30% improvement in energy efficiency by 2040, as established in Puerto Rico Energy Public Policy Act (Act 17). Since hurricanes Irma and Maria in September 2017, DOE and its national laboratories have provided Puerto Rico energy system stakeholders with tools, training, and modeling support to enable planning and operation of the electric power grid with more resilience against further disruptions. On February 2, 2022, DOE, FEMA, and six national laboratories launched the two-year Puerto Rico Grid Resilience and Transitions to 100% Renewable Energy Study (PR100) to conduct comprehensive analysis of stakeholder-driven pathways to Puerto Rico's energy future. The robust and objective energy analysis entails five activities, with an emphasis on power system reliability, resilience, and generation planning. This presentation provides a six-month progress update on the study, including presentation of four initial scenario frameworks defined with extensive stakeholder input.

14 SOLAR ENERGY↗

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids: Preprint

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid↗

Airports as Energy Nodes (ÆNodes) Project Report

Aviation is experiencing an influx of electrified aircraft in the advanced air mobility (AAM) space. The goal of Airports as Energy Nodes (ÆNodes) is to evaluate the impact of AAM and other advanced aircraft adoption growth on the electrical system of existing small to medium hub regional airports to better prepare them for the future while also enhancing resiliency and helping surrounding communities. AAM small passenger air service encompasses vertical takeoff and landing (VTOL), general aviation (GA) and flight training, and nine to thirty passenger conventional aircraft for regional air mobility (RAM) applications all of which include electrical, hybrid, or hydrogen powered varieties. Some challenges that ÆNodes is trying to address include how to utilize existing airport infrastructure to meet the energy needs of AAM growth in a way that is robust to aid in the growth of AAM while also leveraging any airport-hosted energy assets for the surrounding community in emergency situations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A neural-network-enhanced parameter-varying framework for multi-objective model predictive control applied to buildings

Management of the electrical grid is becoming more complex due to the increased penetration of alternative energy generation technologies and a broadening diversity of electric loads. This complexity creates challenges in balancing demand and generation that can increase the potential for grid instabilities. One effective way to address this issue is to leverage previously unexploited demand flexibility through advanced control strategies. In this work, we propose an advanced control method, called adaptive neural parameter-varying model predictive control (ANPV-MPC), to control the temperature and energy consumption of a building via its Heating, Ventilation, and Air Conditioning system. ANPV-MPC combines key ideas in parameter-varying control, adaptive control, and online learning strategies to bridge the gap between computationally efficient linear model predictive control and more accurate nonlinear model predictive control. The novelty in ANPV-MPC is the use of a physics-inspired Bayesian neural network to estimate the coefficients of the parameter-varying linear control model. The Bayesian neural network additionally provides uncertainty estimates, triggering online training to capture evolving building system conditions. We show that ANPV-MPC can approximate the building system dynamics with a 28.39% higher accuracy than traditional linear model predictive control, resulting in 36.23% better control performance without increasing complexity of the optimal control problem. ANPV-MPC also adapts in real time to previously unseen conditions using online learning, further improving its performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Future SDN-HPON Control Plane Architecture and Protocol for On-Demand Terabit End-to-End Extreme-Scale Science Applications

The UC Davis team conducted architecture, algorithm and experimental studies for next generation ultra-high-bandwidth optical networks in support of extreme-scale science applications. In particular, over the course of this 3-year project, the UC Davis team achieved the following main accomplishments: Designed a network architecture for automated multi-domain service provisioning: Designed information exchange schemes between autonomous systems (domains) Designed application programming interfaces to orchestrate resource reservation in data centers, high performance computation facilities, and communication networks belonging to different autonomous systems Experimentally assessed the multi-domain network architecture in a distributed field trial set-up connecting premises in three continents Designed a broker-based orchestrated multi-domain optical networking framework supporting observe-analyze-act cycle based cognitive inter-domain service provisioning: Designed an inter-domain operation mechanism, e.g., topology abstraction, for the broker plane and domain managers to collaboratively accomplish inter-domain service provisioning while respecting the autonomy of each administrative domain Designed an alien wavelength monitoring scheme and an artificial neural network based optical signal-to-noise ratio estimator for quality-of-transmission aware inter-domain service provisioning Developed a deep neural network based multi-domain traffic predictor and a cognitive routing and spectrum assignment algorithm to realize knowledge-based autonomous traffic engineering in multi-domain networks Implemented an optical signal-to-noise ratio estimator and traffic predictor with Google’s Tensor flow and assessed their performance using experimental and synthetic data Demonstrated the benefits of the proposed cognitive schemes with experiments ona two-domain elastic optical network testbed and evaluations on a six-domain simulation framework Built a two-domain software-defined networking control plane testbed using the ONOS platform and demonstrated the workflow of broker and domain manager cooperation, including hierarchical performance monitoring, topology abstraction and cognitive resource allocation. Designed self-learning cognitive service provisioning schemes using advanced machine learning technologies: Designed a self-taught anomaly detection framework for optical networks, including an unsupervised data clustering module for pattern recognition, a supervised data regression and classification module for online anomaly detection, and the system operation principle Experimentally validated the effectiveness of the self-taught anomaly detection framework with various failure/anomaly scenarios. Designed a self-learning autonomic routing, modulation and spectrum assignment (RMSA) provisioning framework for elastic optical networks with deep reinforcement learning. Designed effective modeling and training mechanisms for the self-learning RMSA framework Conducted extensive numerical simulations with various traffic patterns and topologies to verify the advantage of the self-learning RMSA framework.

42 ENGINEERING↗

Multi-static Serial LiDAR for Surveillance and Identification of Marine Life at MHK Installations

Final Report for project DE-EE0006787: Multi-static Serial LiDAR for Surveillance and Identification of Marine Life at MHK Installations. This project developed and tested an optical monitoring system prototype that will be suitable for marine and hydrokinetic (MHK) full project lifecycle observation (baseline, commissioning, and decommissioning), with automated real-time classification of marine animals. This system can be deployed to collect pre-installation baseline species observations at a proposed deployment site with minimal post-processing overhead. To satisfy deployed MHK project species of concern (e.g. Endangered Species Act-listed) monitoring requirements, the system provides automated tracking and notification of the presence of managed animals within established perimeters of MHK equipment and provides high resolution imagery of their behavior through a wide range of conditions. During a project’s decommissioning stage, the system can remain installed to provide resource managers with post-installation data. Our technology, known as an Unobtrusive Multi-static Serial LiDAR Imager (UMSLI), is a technology transfer of underwater distributed LiDAR imaging technology that preserves the advantages of traditional optical and acoustic solutions while overcoming associated disadvantages for MHK environmental monitoring applications. This new approach is a purposefully-designed, reconfigurable adaptation of an existing technology that can be easily mounted on or around different classes of MHK equipment. The system uses low average power red (638nm) laser illumination to be invisible and eye-safe to marine animals and is compact and cost effective. The equipment is designed for long term, maintenance-free operations, to inherently generate a sparse primary dataset that only includes detected anomalies (animal presence information), and to allow robust real-time automated animal classification/identification with a low data bandwidth requirement. Advantages of the technology over others currently being used or being considered for MHK monitoring include: Unlike a conventional camera, the depth of field is near-infinite and limited by attenuation (approximately 5-8 m) rather than focal properties of a lens; Operation in an adaptive mode which can project a sparse grid of pulses with higher peak power for longer range detection (>10 meters) and track animals within a zone of interest with high resolution imagery for identification of marine life at closer range (<5m); System detection limit and Signal-to-Noise-Ratio is superior to a camera, due to rejection of both backscattering component and ambient solar background; Multiple wide-angle pulsed laser illuminators and bucket detectors can be flexibly configured to cover a 4pi steradian (i.e. omnidirectional) scene volume, while also retrieving 3D features of animal targets from timing information; Process and classification framework centered around a novel active learning and incremental classification classifier that enables accurate identification of a variety of marine animals automatically; A two-tiered monitoring architecture and invisible watermarking-based data archiving and retrieving approach ensures significant data reduction while preserving high fidelity monitoring. A methodology to train and optimize the classifier for target species of concern to optimize site monitoring effectiveness. This technological innovation addresses a high priority regulatory requirement to observe marine life interaction near MHK projects. Our solution improves resource manager confidence that any interactions between marine animals and equipment are observed in a cost-effective and automated manner. Without EERE funding, this novel application of multi-static LiDAR would not have been available to the MHK community for environmental monitoring.

16 TIDAL AND WAVE POWER↗

Scalable training of trustworthy and energy-efficient predictive graph foundation models for atomistic materials modeling: a case study with HydraGNN

We present our work on developing and training scalable, trustworthy, and energy-efficient predictive graph foundation models (GFMs) using HydraGNN, a multi-headed graph convolutional neural network architecture. HydraGNN expands the boundaries of graph neural network (GNN) computations in both training scale and data diversity. It abstracts over message passing algorithms, allowing both reproduction of and comparison across algorithmic innovations that define nearest-neighbor convolution in GNNs. This work discusses a series of optimizations that have allowed scaling up the GFMs training to tens of thousands of GPUs on datasets consisting of hundreds of millions of graphs. Our GFMs use multitask learning (MTL) to simultaneously learn graph-level and node-level properties of atomistic structures, such as energy and atomic forces. Using over 154 million atomistic structures for training, we illustrate the performance of our approach along with the lessons learned on two state-of-the-art US Department of Energy (US-DOE) supercomputers, namely the Perlmutter petascale system at the National Energy Research Scientific Computing Center and the Frontier exascale system at Oak Ridge Leadership Computing Facility. The HydraGNN architecture enables the GFM to achieve near-linear strong scaling performance using more than 2000 GPUs on Perlmutter and 16,000 GPUs on Frontier.

97 MATHEMATICS AND COMPUTING↗

Improving Trustworthiness of Data-Driven Power Grid Contingency Analysis With Bayesian Residual Graph Neural Networks

The evolving energy landscape requires novel tools to efficiently perform contingency analysis and reliability assessment of power grids, potentially in real-time. The high computational cost of traditional power flow solvers limits their applicability in practice. Machine learning (ML) surrogates such as deep neural networks (NNs) accelerate power flow solvers computations, enabling high-order contingency analysis and real-time decision-making by learning highly nonlinear functions and integrating grid topology via graph architectures. However, (graph) NNs lack predictive power away from training data and do not provide predictive confidence estimates. Here, we present a Bayesian residual graph NN that integrates knowledge from low-fidelity data via residual training and embeds granular quantification of uncertainties, improving trustworthiness critical for high-consequence decision-making. Applying Bayesian concepts to NNs is challenging due to the high-dimensionality of both the parameter space, complicating derivation of a meaningful prior, and the output space in large grid systems, requiring enhanced techniques to assess the predicted high-dimensional uncertainties. Our contributions include: (1) Deriving a prior for fully connected and graph NNs that leverages low-fidelity data to guide mean predictions and appropriately control prior predictive uncertainty. (2) Integrating this prior within an ensembling with anchoring scheme for efficient approximate posterior inference. (3) Deriving enhanced metrics to assess accuracy of both the mean and uncertainty predictions in high dimensions, appropriately accounting for correlations propagated through graph layers. The resulting Bayesian residual graph NN is tested on a contingency analysis task for 14-bus and 118-bus grids.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Feature Extraction for Pipeline Defects Inspection Based Upon Distributed Acoustic Fiber Optic Sensing Data

Fiber-optic distributed acoustic sensing (DAS) is becoming an increasingly important tool for real-time monitoring of energy and civil infrastructure structural health such as pipelines. We present a systematic theoretical study of the potential for DAS to be directly coupled with guided ultrasonic waves typically used in conventional acoustic non-destructive evaluation (NDE) methods for real-time pipeline health monitoring. We are referring to this innovative new NDE technique as ultrasonic guided wave and optical fiber sensor fusion. In the practical application of DAS coupled with guided ultrasonic waves, the structural design of (1) the specific guided waves excited, (2) the physical installation of the acoustic transducers and the fiber optic sensors, and (3) the functional performance specifications (gauge length, sensitivity, Etc.) of fiber optic DAS have an important influence on overall capabilities of the monitoring system. Meanwhile, physics-based analysis of acoustic waves is still a challenge due to the complex nature of the Lamb wave when it propagates, scatters, and disperses in the presence of structural defects. In this work, we simulate carbon steel pipes relevant for oil and gas pipeline applications with diameters of approximately 6-12” and wall thickness of 0.5” as the objects to be monitored. By establishing and implementing these capabilities, we seek to pursue an in-depth study on structural parameter optimization of DAS network, measurement range, and signal processing with an ultimate goal of increasing the sensitivity and efficacy of DAS to defect identification for various modes of corrosion expected in practice. To study the characteristics of scattered acoustic waves and performance of DAS for defect identification, we simulated the response of DAS for multiple pipe structures, defect types, and DAS sensor network configuration using finite element software Ansys, then the properties of signal response are extracted to construct defect-sensitive features. The raw data simulated, and the associated features extracted can ultimately be utilized as annotated training data to benchmark various designs for DAS applications, guided acoustic excitation sources, and learning model parameters to enhance early detection of potentially problematic defects.

Pipeline Defects Inspection, Fiber-optic sensors, ↗

Scalability analysis of heavy-duty gas turbines using data-driven machine learning

With the increasing integration of variable renewable energy sources into power systems, the role of flexible power generation technologies like gas turbines (GT) in rapid grid balancing remains crucial. This sustained importance underscores the need for scaled and precise modeling of GT to ensure effective integration within evolving energy frameworks. While physics-driven GT models integrate thermodynamics, fluid dynamics, and combustion principles, they often rely on approximate mathematical representations to accommodate scaling that may not capture the actual complex dynamics for GTs and inertial effects associated to GTs with different ratings. In this study, a data-driven model is proposed using machine learning (ML) techniques to conduct GT scalability analysis and performance evaluation with high accuracy. The ML model, trained on data from various operating conditions and performance parameters, aims to uncover intricate relationships and patterns, resembling GT characteristics at different scales (ratings). The model is developed to capture complex system interaction and to adapt to changing operational scenarios at different capacities, providing valuable insights of power system dynamics. In this study, the real-time digital simulator platform was employed to generate training data for the ML model and assess its dynamic characteristics. The ultimate objective was to develop a detailed modeling framework based on governing equations and data-driven ML capable of predicting key performance indicators, in thermal systems such as GTs, including power output, speed, fuel consumption, and exhaust temperature under diverse operating conditions at different scales. The developed ML framework demonstrated high accuracy, with mean relative errors for GT power prediction, reference speed, exhaust temperature, and compressor pressure ratio (CPR) parameters consistently below 0.1% across typical load fluctuation scenarios. Maximum deviations were limited to approximately 0.5 K for exhaust temperature and 0.009 for CPR, underscoring the model’s ability to replicating dynamic GT behavior with high precision. The adaptability of the ML model enables its application across diverse operational conditions and its extension to other thermal systems. By leveraging advanced ML techniques, this study presents a robust and scalable modeling framework that enhances GT simulation precision, facilitating improved integration into evolving power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrated Methane Monitoring Platform Extension, Volume I: Final Technical Report

The IMMPE project, DE-FE0032284, was to enhance methane monitoring technologies and their applications across various natural gas asset classes. The scope included deploying advanced methane detection and monitoring technologies to identify and mitigate fugitive methane emissions, measuring emission rates, and assessing impacts. The findings included the successful mitigation of identified emissions and quantification of emission rates. A key outcome was the development of a comprehensive template and summary of recommendations for methane emissions monitoring, which is replicable for both upstream and downstream applications. Furthermore, the project emphasized the importance of education by providing training opportunities for technicians and regulators, thereby fostering awareness and promoting the adoption of cost-effective methane emissions monitoring and management techniques.

02 PETROLEUM↗