Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dynamic polymer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Advanced Capillary Liquid Chromatography-Mass Spectrometry for Proteomics

The liquid chromatography (LC)-mass spectrometric (MS) analysis of peptides has become a routine method for proteomics – the study of the entire complement of proteins e.g., expressed by a cell under a specific set of conditions at a specific time. Mixtures of peptides, such as those generated from enzymatic (e.g., trypsin) digestion of globally recovered proteins (i.e. a proteome), are typically very complex and >100,000 different molecular species may be observable using MS detection [1]. LC separations implemented prior to MS for broad protein identification have three major roles: 1) to isolate individual components or reduce complexity as much as possible, 2) to increase sensitivity by concentrating the components into narrow zones prior to MS, and 3) to eliminate or displace interfering species (e.g., salts and polymers) that may be present in proteomics samples. A desired quality of LC separation can be achieved from the use of either multiple steps of moderate quality separations, or fewer steps of high power separations. The former approach is generally more easily accessible for very high quality separations due to the variety of commercialized LC platforms available, while the latter still often requires considerable developmental efforts (for both columns and instrumentation). In addition to proteomics data quality, other differences between these two approaches include proteomics analysis time and sample consumption (and subsequent analysis costs), as well as direct impact on potential proteomics applications that have special requirements in terms of analysis coverage, sample size, dynamic range, sensitivity, and throughput.

59 BASIC BIOLOGICAL SCIENCES↗

Gas Sensor Evaluations in Polymer Combustion Product Atmospheres

Toxic gases produced by the combustion or thermo-oxidative degradation of materials such as wire insulation, foam, plastics, or electronic circuit boards in space shuttle or space station crew cabins may pose a significant hazard to the flight crew. Toxic gas sensors are routinely evaluated in pure gas standard mixtures, but the possible interferences from polymer combustion products are not routinely evaluated. The NASA White Sands Test Facility (WSTF) has developed a test system that provides atmospheres containing predetermined quantities of target gases combined with the coincidental combustion products of common spacecraft materials. The target gases are quantitated in real time by infrared (IR) spectroscopy and verified by grab samples. The sensor responses are recorded in real time and are compared to the IR and validation analyses. Target gases such as carbon monoxide, hydrogen cyanide, hydrogen chloride, and hydrogen fluoride can be generated by the combustion of poly(vinyl chloride), polyimide-fluoropolymer wire insulation, polyurethane foam, or electronic circuit board materials. The kinetics and product identifications for the combustion of the various materials were determined by thermogravimetric-IR spectroscopic studies. These data were then scaled to provide the required levels of target gases in the sensor evaluation system. Multisensor toxic gas monitors from two manufacturers were evaluated using this system. In general, the sensor responses satisfactorily tracked the real-time concentrations of toxic gases in a dynamic mixture. Interferences from a number of organic combustion products including acetaldehyde and bisphenol-A were minimal. Hydrogen bromide in the products of circuit board combustion registered as hydrogen chloride. The use of actual polymer combustion atmospheres for the evaluation of sensors can provide additional confidence in the reliability of the sensor response.

Delgado, Rafael H.↗

Polymer electrolyte membranes from fluorinated polyisoprene-block-sulfonated polystyrene: Structural evolution with hydration and heating

Small-angle neutron scattering (SANS) and ultra-small-angle X-ray scattering (USAXS) have been used to study the structural changes in fluorinated polyisoprene/sulfonated polystyrene (FISS) diblock copolymers as they evolved from the dry state to the water swollen state. A dilation of the nanometer-scale hydrophilic domains has been observed as hydration increased, with greater dilation occurring in the more highly sulfonated samples or upon hydration at higher temperatures. Furthermore, a decrease in the order in these phase separated structures is observed upon swelling. The glass transition temperatures of the fluorinated blocks have been observed to decrease upon hydration of these materials, and at the highest hydration levels, differential scanning calorimetry (DSC) has shown the presence of tightly bound water. A precipitous drop in the mechanical integrity of the 50% sulfonated materials is also observed upon exceeding the glass transition temperature (Tg), as measured by dynamic mechanical analysis (DMA).

36 MATERIALS SCIENCE↗

Fluorine-Free Precise Polymer Electrolyte for Efficient Proton Transport: Experiments and Simulations

Designing polymers with controlled nanoscale morphologies and scalable synthesis is of great interest in the development of fluorine-free materials for proton-exchange membranes in fuel cells. This study focuses on a precision polyethylene with phenylsulfonic acid branches at every fifth carbon, p5PhSA, with a high ion-exchange capacity (4.2 mmol/g). The polymers self-assemble into hydrophilic and hydrophobic co-continuous nanoscale domains. In the hydrated state, the hydrophilic domain, composed of polar sulfonic acid moieties and water, serves as a pathway for efficient mesoscopic proton conductivity. The morphology and proton transport of p5PhSA are evaluated under hydrated conditions using in situ X-ray scattering and electrochemical impedance spectroscopy techniques. Additionally, at 40 °C and 95% relative humidity, the proton conductivity of p5PhSA is 0.28 S/cm, which is four times greater than Nafion 117 under the same conditions. Atomistic molecular dynamics (MD) simulations are also used to elucidate the interplay between the structure and the water dynamics. The MD simulations show strong nanophase separation between the percolated hydrophilic and hydrophobic domains over a wide range of water contents. The percolated hydrophilic nanoscale domain facilitates the rapid proton transport in p5PhSA and demonstrates the potential of precise hydrocarbon-based polymers as processible and effective proton-exchange membranes.

36 MATERIALS SCIENCE↗

Thermo-mechanical deterioration and molecular degradation of 3D-printed methacrylate-based polymer in various chemical environments

The advancement of additive manufacturing (AM) has accelerated the development of stereolithographic (SLA) photo-curable resins, particularly methacrylate-based polymers, due to the ability to their high-resolution, robust mechanical properties, and suitability. However, their long-term performance in chemical environments remains poorly understood. This study investigates the extent and mechanisms of degradation on an SLA-printed methacrylate-based polymer subjected to various chemicals, including polar and non-polar solvents, as well as strongly acidic aqueous solutions over a 12-week accelerated aging period. A comprehensive analytical approach incorporating swelling kinetics, surface morphology, tensile and dynamic mechanical analysis (DMA), Fourier-transform infrared (FTIR) spectroscopy, and mass spectrometry (MS) was employed to characterize chemical absorption, structural integrity, and leached products. Results reveal that degradation severity is governed by both the polarity and reactivity of the chemical environment. Notably, exposure to 6 mol L -1 HNO₃ induced the most severe deterioration, with over threefold higher swelling compared to other media, and significant reductions in tensile strength, tensile modulus, and glass transition temperature (T g ). In contrast, specimens aged in non-polar solvents (xylene and dodecane) exhibited negligible chemical interaction and retained mechanical performance. FTIR and MS analyses identified acid-catalyzed hydrolysis of ester groups as prominent degradation pathways in acidic media, while diffusion-controlled plasticization prevailed in polar solvents. Furthermore, this study provides valuable insights into the chemical stability of SLA-printed polymers and develops predictive degradation profiles that are crucial for designing durable polymer systems for advanced industrial use.

36 MATERIALS SCIENCE↗

Trace explosive residue detection of HMX and RDX in post-detonation dust from an open-air environment

Explosives are often used in industry, geology, mining, and other applications, but it is not always clear what remains after a detonation or the fate and transport of any residual material. The goal of this study was to determine to what extent intact molecules of high explosive (HE) compounds are detectable and quantifiable from post-detonation dust and particulates in a field experiment with varied topography. We focused on HMX (1,3,5,7-Tetranitro-1,3,5,7-tetrazocane), which is less studied in field detonation literature, as the primary explosive material and RDX (1,3,5-Trinitroperhydro-1,3,5-triazine) as the secondary material. The experiment was conducted at Site 300, Lawrence Livermore National Laboratory’s Experimental Test Site, in California, USA. Two 20.4 kg and one 40.8 kg above ground explosions (primarily comprised of LX-14, an HMX-based polymer-bonded high explosive) were detonated on an open-air firing area on separate days. The complex terrain of the firing area (e.g., buildings, berm, low-height obstacles) was advantageous to study HE deposition in relation to plume dynamics. Three types of samples were collected up to 100 m away from each shot: surface swipes of aluminum plates, surface swipes of fixed objects, and filters from air samples. We used atmospheric flow tube-mass spectrometry (AFT-MS) to quantify picogram levels of molecular residue of HE material in the post-detonation dust. An aliquot of sample extract in methanol (e.g., 1 µL of 0.5 mL) was placed onto a resistive material and then thermally desorbed into the AFT-MS. We successfully detected and quantified both HMX and RDX in many of the samples. Based on mass (pg) detected and solution dilution, we back-calculated the mass collected on the swipe or filter (ng per sample). The aerial distribution of molecular residue was consistent with the path of the plume, which was strongly determined by wind speed and direction at the time of each shot. The quantity of material detected appeared to correlate more with distance from the shot and the wind conditions than with shot size. This study demonstrates that the picogram detection levels of AFT-MS are well-suited for quantification of analytes (e.g., HMX and RDX) in environmental samples.

atmospheric flow tube-mass spectrometry (AFT-MS), ↗

A Limited Comparison of the Thermal Durability of Polyimide Candidate Matrix Polymers with PMR-15

Studies were conducted with six different candidate high-temperature neat matrix resin specimens of varied geometric shapes to investigate the mechanisms involved in the thermal degradation of polyimides like PMR-15. The metrics for assessing the quality of these candidates were chosen to be glass transition temperature (T(sub g)), thermo-oxidative stability, dynamic mechanical properties, microstructural changes, and dimensional stability. The processing and mechanical properties were not investigated in the study reported herein. The dimensional changes and surface layer growth were measured and recorded. The data were in agreement with earlier published data. An initial weight increase reaction was observed to be dominating at the lower temperatures. However, at the more elevated temperatures, the weight loss reactions were prevalent and probably masked the weight gain reaction. These data confirmed the findings of the existence of an initial weight gain reaction previously reported. Surface- and core-dependent weight losses were shown to control the polymer degradation at the higher temperatures.

Bowles, Kenneth J.↗

In-situ Roll-to-Roll Printing of Highly Efficient Organic Solar Cells

This project focuses on developing a roll-to-roll printing setup for organic solar cells with the capability to follow the film formation in situ with small and wide angle X-ray scattering, and to improve the performance of printed organic solar cells. We demonstrated the use of the printing setup to capture important aspects of existing industrial printing methods, which ensures that the solar cell performance achieved in our printing experiments would be largely retained in an industrial fabrication process. We employed both known and newly synthesized polymers as the donor and acceptor materials, and we studied the morphological changes in real time during the printing process by X-ray scattering. Our experimental efforts are also accompanied by theoretical modeling of both the fluid dynamic aspects of the printing process and the nucleation and crystallization kinetics during the film formation. The combined insight into the printing process gained from the research provides a detailed understanding of the factors governing the printed solar cell’s performance. Finally using the knowledge we gained, we demonstrated large area ( > 10 cm2) printed organic solar cells with more than 5 percent power conversion efficiency, which is best achieved performance for roll-to-roll printed organic solar cells.

14 SOLAR ENERGY↗

Efficiently sampling conformations and pathways using the concurrent adaptive sampling (CAS) algorithm

Molecular dynamics (MD) simulations are useful in obtaining thermodynamic and kinetic properties of bio-molecules but are limited by the timescale barrier, i.e., we may be unable to efficiently obtain properties because we need to run microseconds or longer simulations using femtoseconds time steps. While there are several existing methods to overcome this timescale barrier and efficiently sample thermodynamic and/or kinetic properties, problems remain in regard to being able to sample un- known systems, deal with high-dimensional space of collective variables, and focus the computational effort on slow timescales. Hence, in this work, a new sampling method, called the “Concurrent Adaptive Sampling (CAS) algorithm,” has been developed to tackle these three issues and efficiently obtain conformations and pathways. The method is not constrained to use only one or two collective variables, unlike most reaction coordinate-dependent methods. Instead, it can use a large number of collective vari- ables and uses macrostates (a partition of the collective variable space) to enhance the sampling. The exploration is done by running a large number of short simula- tions, and a clustering technique is used to accelerate the sampling. In this paper, we introduce the new methodology and show results from two-dimensional models and bio-molecules, such as penta-alanine and triazine polymer

59 BASIC BIOLOGICAL SCIENCES↗

Nanomodified Methyl Methacrylate Polymer for Sealing of Microscale Defects in Wellbore Systems

Microscale defects (microannuli) at the steel-cement and rock-cement interfaces are a significant cause of failure in the integrity of wellbore systems. Microscale defects/microcracks as small as 30 μm are sufficient to create a significant leakage pathway for fluids. Here, the authors propose the use of nanomodified methyl methacrylate (NM-MMA) polymer as a seal material for 30-μm microcracks. Four materials were evaluated for their ability to serve as an effective seal material to seal 30-μm microcracks: microfine cement, epoxy, methyl methacrylate (MMA), and NM-MMA incorporating 0.5% by weight aluminum nanoparticles (ANPs). The seal materials’ bond strengths with shale were investigated using push-out tests. In addition, the ability to flow fluid through the microcracks was investigated using sagittal microscopic images. Viscosity, surface tension, and contact angle measurements explain the superior ability of MMA seal materials to flow into very thin microcracks compared with other materials. Post-test analysis shows MMA repair materials are capable of completely filling the microcracks. In addition, incorporating ANPs in MMA resulted in significant improvement in seal material ductility. Dynamic mechanical analysis (DMA) showed that incorporating ANPs in MMA reduced the creep compliance and improved creep recovery of NM-MMA. X-ray diffraction (XRD) analysis shows that incorporating ANPs in MMA resin increases the degree of polymer crystallization, resulting in significant improvement in seal material ductility.

36 MATERIALS SCIENCE↗

Dynamic, hollow nanotubular networks with superadjustable pH-responsive and temperature resistant rheological characteristics

Recently, the interest in stimuli-responsive and adaptable materials has continuously grown in various fields and applications. For such responsive systems, different triggers, including pH, light, pressure, temperature, and electric field, have been utilized to control dynamics and assembly. Among these, pH is one of the most convenient, energy-efficient, and economic modalities. Besides, plenty of traditional materials have poor thermal and salt stability, limiting their applications. Herein, we report a new design of a pH-responsive viscoelastic supramolecular complex (VSC) based on commplexation of a new long-chain amino-amide and maleic acid. In this study, the system demonstrated a sol–gel-sol transition from pH 2 to 10, with the largest static viscosity occurring at pH 6 (~1000 Pa·s) and the smallest viscosity at pH 4 (~3.3 Pa·s), indicating ~ 300-fold control over the viscosity. For a given concentration, the static viscosity of VSC was about 15 times larger than that of CTAB/NaSal, a well-established dynamic viscoelastic system, and no pH-responsiveness was observed for the traditional system. In addition, the VSC demonstrated a superior temperature tolerance and lower temperature dependence. The potential of these intriguing dynamics viscoelastic systems was evaluated for hydraulic fracturing and enhanced oil recovery applications. Proppant settling velocity of DMAA/MA was 500 ~ 1000 times lower than that of CTAB/NaSal and common traditional polymers. Likewise, the oil recovery percentage could be significantly improved with the utilization of DMAA/MA compared to the CTAB/NaSal (86 % vs 52 %). Aside from applications in hydraulic fracturing and enhanced oil recovery, we anticipate that the intriguing rheological properties of this viscoelastic system can be beneficial for other chemical engineering applications including personal care products, cosmetics, lubricants, and biomedical gels.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Intermolecular Structural Change for Thermoswitchable Polymeric Photosensitizer

A switchable photosensitizer (PS), which can be activated at a spe-cific condition beside light, has tremendous advantages for photo-dynamic therapy (PDT). Herein, we developed a thermo-switchable polymeric photosensitizer (T-PPS) by conjugating PS (Pheophor-bide-a, PPb-a) to a temperature-responsive polymer backbone of biocompatible hydroxypropyl cellulose (HPC). Self-quenched PS molecules linked in close proximity by pi-pi stacking in T-PPS were easily transited to an active monomeric state by the tempera-ture induced phase transition of polymer backbones. The tempera-ture responsive inter-molecular interaction changes of PS molecules in T-PPS were demonstrated in synchrotron small-angle X-ray scattering (SAXS) and UV-Vis spectrophotometer analysis. The T-PPS allowed switchable activation and synergistically enhanced cancer cell killing effect at the hyperthermia temperature (45 °C). Our developed T-PPS has the considerable potential not only as a new class of photomedicine in clinics but also as a biosensor based on temperature responsiveness.

Park, Wooram↗

Evidence for Crystalline Structure in Dynamically-Compressed Polyethylene up to 200 GPa

Abstract We investigated the high-pressure behavior of polyethylene (CH 2 ) by probing dynamically-compressed samples with X-ray diffraction. At pressures up to 200 GPa, comparable to those present inside icy giant planets (Uranus, Neptune), shock-compressed polyethylene retains a polymer crystal structure, from which we infer the presence of significant covalent bonding. The A 2 /m structure which we observe has previously been seen at significantly lower pressures, and the equation of state measured agrees with our findings. This result appears to contrast with recent data from shock-compressed polystyrene (CH) at higher temperatures, which demonstrated demixing and recrystallization into a diamond lattice, implying the breaking of the original chemical bonds. As such chemical processes have significant implications for the structure and energy transfer within ice giants, our results highlight the need for a deeper understanding of the chemistry of high pressure hydrocarbons, and the importance of better constraining planetary temperature profiles.

36 MATERIALS SCIENCE↗

Light-activated microtubule-based two-dimensional active nematic

We assess the ability of two light responsive kinesin motor clusters to drive dynamics of microtubule-based active nematics: opto-K401, a processive motor, and opto-K365, a non-processive motor. Measurements reveal an order of magnitude improvement in the contrast of nematic flow speeds between maximally- and minimally-illuminated states for opto-K365 motors when compared to opto-K401 construct. For opto-K365 nematics, we characterize both the steady-state flow and defect density as a function of applied light. We also examine the transient behavior as the system switches between steady-states upon changes in light intensities. Although nematic flows reach a steady state within tens of seconds, the defect density exhibits transient behavior for up to 10 minutes, showing a separation between small-scale active flows and system-scale structural states. Furthermore, our work establishes an experimental platform that can exploit spatiotemporally-heterogeneous patterns of activity to generate targeted dynamical states.

42 ENGINEERING↗

Dynamic response of phenolic resin and its carbon-nanotube composites to shock wave loading

We investigate with nonreactive molecular dynamics simulations the dynamic response of phenolic resin and its carbon-nanotube (CNT) composites to shock wave compression. For phenolic resin, our simulations yield shock states in agreement with experiments on similar polymers except the “phase change” observed in experiments, indicating that such phase change is chemical in nature. The elastic–plastic transition is characterized by shear stress relaxation and atomic-level slip, and phenolic resin shows strong strain hardening. Shock loading of the CNT-resin composites is applied parallel or perpendicular to the CNT axis, and the composites demonstrate anisotropy in wave propagation, yield and CNT deformation. The CNTs induce stress concentrations in the composites and may increase the yield strength. Our simulations indicate that the bulk shock response of the composites depends on the volume fraction, length ratio, impact cross-section, and geometry of the CNT components; the short CNTs in current simulations have insignificant effect on the bulk response of resin polymer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Implosion dynamics measurements at the National Ignition Facility

Measurements have been made of the in-flight dynamics of imploding capsules indirectly driven by laser energies of 1-1.7 MJ at the National Ignition Facility [Miller et al., Nucl. Fusion 44, 228 (2004)]. These experiments were part of the National Ignition Campaign [Landen et al., Phys. Plasmas 18, 051002 (2011)] to iteratively optimize the inputs required to achieve thermonuclear ignition in the laboratory. Using gated or streaked hard x-ray radiography, a suite of ablator performance parameters, including the time-resolved radius, velocity, mass, and thickness, have been determined throughout the acceleration history of surrogate gas-filled implosions. These measurements have been used to establish a dynamically consistent model of the ablative drive history and shell compressibility throughout the implosion trajectory. First results showed that the peak velocity of the original 1.3-MJ Ge-doped polymer (CH) point design using Au hohlraums reached only 75% of the required ignition velocity. Several capsule, hohlraum, and laser pulse changes were then implemented to improve this and other aspects of implosion performance and a dedicated effort was undertaken to test the sensitivity of the ablative drive to the rise time and length of the main laser pulse. Changing to Si rather than Ge-doped inner ablator layers and increasing the pulse length together raised peak velocity to 93% {+-} 5% of the ignition goal using a 1.5 MJ, 420 TW pulse. Further lengthening the pulse so that the laser remained on until the capsule reached 30% (rather than 60%-70%) of its initial radius, reduced the shell thickness and improved the final fuel {rho}R on companion shots with a cryogenic hydrogen fuel layer. Improved drive efficiency was observed using U rather than Au hohlraums, which was expected, and by slowing the rise time of laser pulse, which was not. The effect of changing the Si-dopant concentration and distribution, as well as the effect of using a larger initial shell thickness were also examined, both of which indicated that instabilities seeded at the ablation front are a significant source of hydrodynamic mix into the central hot spot. Additionally, a direct test of the surrogacy of cryogenic fuel layered versus gas-filled targets was performed. Together all these measurements have established the fundamental ablative-rocket relationship describing the dependence of implosion velocity on fractional ablator mass remaining. This curve shows a lower-than-expected ablator mass at a given velocity, making the capsule more susceptible to feedthrough of instabilities from the ablation front into the fuel and hot spot. This combination of low velocity and low ablator mass indicates that reaching ignition on the NIF will require >20 {mu}m ({approx}10%) thicker targets and laser powers at or beyond facility limits.

36 MATERIALS SCIENCE↗

Preparation and characterization of polyethylene glycol diacrylate microgels using electron beam radiation

The use of microemulsion in the development of nanosized gels based on polyethylene glycol diacrylate (PEGDA) is demonstrated. PEGDA was solubilized in n-heptane with use of sodium docusate (AOT) at 0.15M concentration to form reverse micelles. These micelles were than irradiated at 5, 10, 15, 20 and 25 kGy using electron beam (EB) to crosslink the entrapped polymer in the micelles. Ionizing radiation was imparted to the emulsions to generate crosslinking reaction in the micelles formed. The nanosized gels were evaluated in terms of particle diameter using dynamic light scattering (DLS) and the images of the nanosized gels were studied using transmission electron microscopy (TEM). Results show that the size and shape of the particles are influenced by concentration of PEGDA and radiation dose. This study showed that this method can be utilized to produce nanosized gels.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser-driven flyer plate impact: Computational studies guided by experiments

We present a computational approach using a multimaterial, arbitrary Lagrangian–Eulerian code termed ALE3D to model the nanosecond/micrometer dynamics of the launch of 0.5–4.5 km/s laser-driven metal flyer plates and the impact with stationary targets of Pyrex and fused silica glasses, and Lexan and Plexiglas polymers, producing pressures in the target in the range of 5–20 GPa. The simulations are compared to experimental results where the flyer velocity profile and the velocity profile imparted to the target material were measured with high-speed velocimetry. The experimental flyer launch by a high-intensity pulsed laser is modeled by depositing heat into a thin vaporizable layer under the flyer plate. This model produces a flyer plate that has not been exposed to the laser pulse, allowing us to compare the properties of the real flyer to a simulated ideal flyer. The simulations of target impact are generally in good agreement with the experiment except at the highest impact velocities where the shock release process in the experiment is slower than that in the simulation. The cause of this disagreement is attributed to an inadequate description of the shock viscosity during the nanosecond unloading process.

Stekovic, Svjetlana (ORCID:0000000163878070)↗