Search NASA⌕ Search

SEARCH · Search NASA

Results for “Error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Mechanism of Error-Free Bypass of the Environmental Carcinogen N -(2'-Deoxyguanosin-8-yl)-3-aminobenzanthrone Adduct by Human DNA Polymerase η

The environmental pollutant 3-nitrobenzanthrone produces bulky aminobenzanthrone (ABA) DNA adducts with both guanine and adenine nucleobases. A major product occurs at the C8 position of guanine (C8-dG-ABA). These adducts present a strong block to replicative polymerases but, remarkably, can be bypassed in a largely error-free manner by the human Y-family polymerase η (hPol η). Here, we report the crystal structure of a ternary Pol•DNA•dCTP complex between a C8-dG-ABA-containing template:primer duplex and hPol η. The complex was captured at the insertion stage and provides crucial insight into the mechanism of error-free bypass of this bulky lesion. Specifically, bypass involves accommodation of the ABA moiety inside a hydrophobic cleft to the side of the enzyme active site and formation of an intra-nucleotide hydrogen bond between the phosphate and ABA amino moiety, allowing the adducted guanine to form a standard Watson–Crick pair with the incoming dCTP.

Patra, Amritraj↗

Quantification and Statistical Analysis of Errors Related to the Approximate Description of Active Site Models in Metal‐Exchanged Zeolites

Abstract Metal‐exchanged zeolites are complex catalytic systems with great potential for applications in hydrocarbon conversion processes. The numerous combinations of zeotypes and metal‐based Lewis acid motifs create a vast material space that can only be effectively navigated with robust structure‐function relationships. Exhaustive modeling of extraframework metal sites in all crystallographically distinct framework positions is not practical; thus, we quantified the uncertainties arising from the use of simplified active site representations using the C−H bond activation in methane as a probe reaction. Density functional theory calculations and statistical analysis of associated error ensembles suggest that the Lewis acid identity primarily determines the reactivity of the zeolite towards methane activation, with other factors such as zeolite model characteristics deemed secondary. The error ensemble distributions were used to predict the relative probability of creating active C−H bond scission fragments in metal‐exchanged zeolites, and thus can be used to efficiently screen various metal‐exchange candidates in their efficacy towards hydrocarbon conversion.

Thirumalai, Hari↗

Celestial Quantum Error Correction. Part II. From qudits to celestial CFT

A holographic CFT description of asymptotically flat spacetimes inherits vacuum degeneracies and IR divergences from its gravitational dual. We devise a Quantum Error Correcting (QEC) framework to encode both effects as correctable fluctuations on the CFT dual. The framework is physically motivated by embedding a chain of qudits in the so-called Klein spacetime and then taking a continuum 𝑁 → ∞ limit. At finite 𝑁 the qudit chain 1) enjoys a discrete version of celestial symmetries and 2) supports a Gottesman-Kitaev-Preskill (GKP) code. The limit results in hard states with quantized BMS hair in the celestial torus forming the logical subspace, robust under errors induced by soft radiation. Technically, the construction leverages the recently studied 𝑤 1+∞ hierarchy of soft currents and its realization from a sigma model in twistor space.

79 ASTRONOMY AND ASTROPHYSICS↗

Diagnosing and Correcting Mass Accuracy and Signal Intensity Error Due to Initial Ion Position Variations in a MALDI TOFMS

Frustrated by worse than expected error for both peak area and time-of-flight (TOF) in matrix assisted laser desorption ionization (MALDI) experiments using samples prepared by electrospray deposition, it was finally determined that there was a correlation between sample location on the target plate and the measured TOF/peak area. Variations in both TOF and peak area were found to be due to small differences in the initial position of ions formed in the source region of the TOF mass spectrometer. These differences arise largely from misalignment of the instrument sample stage, with a smaller contribution arising from the non-ideal shape of the target plates used. By physically measuring the target plates used and comparing TOF data collected from three different instruments, an estimate of the magnitude and direction of the sample stage misalignment was determined for each of the instruments. A correction method was developed to correct the TOFs and peak areas obtained for a given combination of target plate and instrument. Two correction factors are determined, one by initially collecting spectra from each sample position used and another by using spectra from a single position for each set of samples on a target plate. For TOF and mass values, use of the correction factor reduced the error by a factor of 4, with the relative standard deviation (RSD) of the corrected masses being reduced to 12-24 ppm. For the peak areas, the RSD was reduced from 28% to 16% for samples deposited twice onto two target plates over two days. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of an Impedance-Matched Test Fixture with the Modal Projection Error

Across many industries and engineering disciplines, components and systems are designed and deployed into their operational environment of intended use. It is the desire of the design agency to be able to predict whether their component or system will function in its shock and vibration environments or if it will fail due to mechanical stresses. One method to determine if the component will survive the shock and vibration environments is to expose the component to the operational environment in a laboratory. One difficulty in executing a representative laboratory test is that the component may not have the same boundary condition in the laboratory as in the operational configuration. This paper examines the use of parameterized optimization to design the test fixture in order to better match the operational configuration. Several frequency and modal-based objective functions are examined for the optimization. The study shows that the Modal Projection Error objective function performs the best of the functions studied. The efficacy of the Modal Projection Error is demonstrated with respect to dynamic test fixture design on several analytical and experimental exemplars.

dynamic↗

Error correction in short time steps during the application of quantum gates

We propose a modification of the standard quantum error-correction method to enable the correction of errors that occur due to the interaction with a noisy environment during quantum gates without modifying the codification used for memory qubits. Using a perturbation treatment of the noise that allows us to separate it from the ideal evolution of the quantum gate, we demonstrate that in certain cases it is necessary to divide the logical operation in short time steps intercalated by correction procedures. A prescription of how these gates can be constructed is provided, as well as a proof that, even for the cases when the division of the quantum gate in short time steps is not necessary, this method may be advantageous for reducing the total duration of the computation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Online randomized interpolative decomposition with a posteriori error estimator for temporal PDE data reduction

Traditional low-rank approximation is a powerful tool for compressing large data matrices that arise in simulations of partial differential equations (PDEs), but suffers from high computational cost and requires several passes over the PDE data. The compressed data may also lack interpretability thus making it difficult to identify feature patterns from the original data. Here, to address these issues, we present an online randomized algorithm to compute the interpolative decomposition (ID) of large-scale data matrices in situ. Compared to previous randomized IDs that used the QR decomposition to determine the column basis, we adopt a streaming ridge leverage score-based column subset selection algorithm that dynamically selects proper basis columns from the data and thus avoids an extra pass over the data to compute the coefficient matrix of the ID. In particular, we adopt a single-pass error estimator based on the non-adaptive Hutch++ algorithm to provide real-time error approximation for determining the best coefficients. As a result, our approach only needs a single pass over the original data and thus is suitable for large and high-dimensional matrices stored outside of core memory or generated in PDE simulations. A strategy to improve the accuracy of the reconstructed data gradient, when desired, within the ID framework is also presented. We provide numerical experiments on turbulent channel flow and ignition simulations, and on the NSTX Gas Puff Image dataset, comparing our algorithm with the offline ID algorithm to demonstrate its utility in real-world applications.

Column subset selection↗

Impact of electron density on the fixed-node errors in Quantum Monte Carlo of atomic systems

We analyze the effect of increasing charge density on the fixed-node errors in diffusion Monte Carlo (FNDMC). We compare FNDMC ground state energies of 4-electron atomic systems with nuclear charge using Hartree–Fock and restricted Configuration Interaction trial wave functions. We perform these calculations for several different values of the nuclear charge, and we analyze the systematic trends of the recovered correlation energies as a function of . For this testing system we demonstrate that the fixed-node error of the Hartree–Fock trial wave functions increases linearly with increasing the nuclear charge.

Chemistry↗

Piecewise linear approximation with minimum number of linear segments and minimum error: A fast approach to tighten and warm start the hierarchical mixed integer formulation

In several areas of economics and engineering, it is often necessary to fit discrete data points or approximate nonlinear functions with continuous functions. Piecewise linear (PWL) functions are a convenient way to achieve this. PWL functions can be modeled in mathematical problems using only linear and integer variables. Moreover, there is a computational benefit in using PWL functions that have the least possible number of segments. This work proposes a novel hierarchical mixed integer linear programming (MILP) formulation that identifies a continuous PWL approximation with minimum number of linear segments for a given target maximum error. The proposed MILP formulation also identifies the solution with the least maximum error among the solutions with minimum number of segments. Then, this work proposes a fast iterative algorithm that identifies non necessarily continuous PWL approximations by solving O(S log N) linear programming (LP) problems, where N is the number of data points and S is the minimum number of segments in the non necessarily continuous case. This work demonstrates that tight bounds for the MILP problem can be derived from these approximations. Next, a fast algorithm is introduced to transform a non necessarily continuous PWL approximation into a continuous one. Finally, the tight bounds and the continuous PWL approximations are used to tighten and warm start the MILP problem. The tightened formulation is shown in experimental results to be more efficient, especially for large data sets, with a solution time that is up to two orders of magnitude less than the existing literature.

97 MATHEMATICS AND COMPUTING↗

Techno-economic implications and cost of forecasting errors in solar PV power production using optimized deep learning models

Accurate solar Photovoltaic (PV) power forecasting is important for enhancing both the performance and economic feasibility of PV systems. This study evaluates several deep learning models, including Dense Neural Networks (DNN), Long Short-Term Memory (LSTM), Convolutional Neural Networks (CNN), and a hybrid LSTMCNN model, for predicting PV power production one day in advance. Prior to optimization, the models exhibited relatively high errors, with the best model (DNN) achieving a Root Mean Square Error (RMSE) of 31.13 kW and a coefficient of determination (R 2 ) of 62.15 %. After employing Bayesian optimization, the LSTM-CNN model demonstrated the best performance, with the RMSE reduced to 9.79 kW and R 2 improved to 97.62 %, showcasing significant enhancement in predictive accuracy. Here, the economic evaluation considered three cases: rewards for underestimation (0.08 USD/kWh), no rewards, and penalties for both over-and underestimation (120 % of the utility tariff). In the rewards scenario, the LSTM-CNN model reduced the Levelized Cost of Electricity (LCOE) by 4 %, while in the penalty scenario, a backup diesel generator would have increased the LCOE by 49 %. Additionally, the LSTM-CNN model minimized financial losses, achieving the lowest penalties and maximizing net cash flow compared to other models, demonstrating its overall technical and economic superiority.

Deep learning↗

A study of examiner accuracy in cartridge case comparisons. Part 1: Examiner error rates

This report describes a study undertaken to estimate examiner (not laboratory) error rates for false Identifications and false Eliminations when comparing an unknown to a collection of three known cartridge cases. Volunteer active examiners with Association of Firearm and Toolmark Examiners (AFTE) membership or working in laboratories that participate in the Association of Crime Laboratory Directors (ASCLD) were provided with 15 sets of three known and one questioned cartridge cases fired from a collection of 25 new Ruger SR9 handguns. Remington 9-mm Luger (manufacturer designation L9MM3) ammunition was used and comparison sets were made up of cartridge cases fired within 100 cartridges of each other for each gun. Examiners were provided with a background survey, an answer sheet allowing for the AFTE Range of Conclusions, and return shipping materials. In addition to determining whether the known and questioned cartridge cases were fired with the same handgun, examiners were also asked to assess how many of the three knowns in each set were suitable for comparison, providing an estimated rate of how often each firearm used in the study produces useable, quality marks. The participating examiners were provided with both same-source and different-source comparison sets allowing the study to assess both error rates. Responses were received from 218 participating examiners. The overall rate of false Eliminations was estimated as 0.367% from comparisons known to be from the same firearm but reported as Eliminations. The overall rate of false Identifications was estimated as 1.01% from comparisons known to be from different firearms but reported as Identifications. The rates are not uniform across the sample population with a few examiners providing most of the false Identification responses. Rates of poor-quality mark production varied across the 25 sample handguns; those rates were 2.3% (±1.4%). Both false Elimination and false Identification rates are comparable to or lower than the rate of production of poor-quality marks by the firearms used in this study.

99 GENERAL AND MISCELLANEOUS↗

Overview of oxygen opacity experiments at the National Ignition Facility and investigation of potential systematic errors

Experiments to measure oxygen opacity at stellar interior conditions have been performed at the National Ignition Facility in a Discovery Science campaign. These experiments utilize the Opacity-on-NIF platform with a sample comprised of O, Mg, and Si. The spectral data from the Opacity Spectrometer cover the 1000–2000 eV photon energy range showing bound-free continuum absorption from O and line absorption from Mg and Si. DANTE and the Gated X-ray Detector are employed to measure the sample plasma’s temperature and density, respectively. Initial data show lower transmission than expected by theoretical models, raising questions of whether potential background or data uniformity concerns could produce systematic errors in the inferred transmission. Here, we investigate three concerns thought to be important for the oxygen opacity data, including instrumental scattered background, sample self-emission non-uniformity, and backlight continuum non-uniformity. Additionally, we show the effect of a recently developed method to account for 2nd order crystal reflection. The total effect of these concerns on one experiment is found to be small compared to the observed difference between the inferred transmission and a model calculation at the inferred temperature and density. Thus, we conclude that these potential sources of systematic error cannot account for the observed difference, increasing the likelihood of a real effect due to the high temperature and density conditions. However, because this is only a single experiment, we cannot make a firm conclusion. More experiments measuring the opacity and necessary calibrations are needed to assess the reproducibility and uncertainty of this result.

79 ASTRONOMY AND ASTROPHYSICS↗

Dose Uncertainties in IMPT for Oropharyngeal Cancer in the Presence of Anatomical, Range, and Setup Errors

Purpose: Setup, range, and anatomical uncertainties influence the dose delivered with intensity modulated proton therapy (IMPT), but clinical quantification of these errors for oropharyngeal cancer is lacking. We quantified these factors and investigated treatment fidelity, that is, robustness, as influenced by adaptive planning and by applying more beam directions. Methods and Materials: We used an in-house treatment planning system with multicriteria optimization of pencil beam energies, directions, and weights to create treatment plans for 3-, 5-, and 7-beam directions for 10 oropharyngeal cancer patients. The dose prescription was a simultaneously integrated boost scheme, prescribing 66 Gy to primary tumor and positive neck levels (clinical target volume-66 Gy; CTV-66 Gy) and 54 Gy to elective neck levels (CTV-54 Gy). Doses were recalculated in 3700 simulations of setup, range, and anatomical uncertainties. Repeat computed tomography (CT) scans were used to evaluate an adaptive planning strategy using nonrigid registration for dose accumulation. Results: For the recalculated 3-beam plans including all treatment uncertainty sources, only 69% (CTV-66 Gy) and 88% (CTV-54 Gy) of the simulations had a dose received by 98% of the target volume (D98%) >95% of the prescription dose. Doses to organs at risk (OARs) showed considerable spread around planned values. Causes for major deviations were mixed. Adaptive planning based on repeat imaging positively affected dose delivery accuracy: in the presence of the other errors, percentages of treatments with D98% >95% increased to 96% (CTV-66 Gy) and 100% (CTV-54 Gy). Plans with more beam directions were not more robust. Conclusions: For oropharyngeal cancer patients, treatment uncertainties can result in significant differences between planned and delivered IMPT doses. Given the mixed causes for major deviations, we advise repeat diagnostic CT scans during treatment, recalculation of the dose, and if required, adaptive planning to improve adequate IMPT dose delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Human DNA polymerase η promotes RNA-templated error-free repair of DNA double-strand breaks

A growing body of evidence indicates that RNA plays a critical role in orchestrating DNA double-strand break repair (DSBR). Recently, we showed that homologous nascent RNA can be used as a template for error-free repair of double-strand breaks (DSBs) in the transcribed genome and to restore the missing sequence at the break site via the transcription-coupled classical nonhomologous end-joining (TC-NHEJ) pathway. TC-NHEJ is a complex multistep process in which a reverse transcriptase (RT) is essential for synthesizing the DNA strand from template RNA. However, the identity of the RT involved in the TC-NHEJ pathway remained unknown. Here, we report that DNA polymerase eta (Pol η), known to possess RT activity, plays a critical role in TC-NHEJ. We found that Pol η forms a multiprotein complex with RNAP II and other TC-NHEJ factors, while also associating with nascent RNA. Moreover, purified Pol η, along with DSBR proteins PNKP, XRCC4, and Ligase IV can fully repair RNA templated 3'-phosphate-containing gapped DNA substrate. In addition, we demonstrate here that Pol η deficiency leads to accumulation of R-loops and persistent strand breaks in the transcribed genes. Finally, we determined that, in Pol η depleted but not in control cells, TC-NHEJ-mediated repair was severely abrogated when a reporter plasmid containing a DSB with several nucleotide deletion within the E. coli lacZ gene was introduced for repair in lacZ-expressing mammalian cells. Thus, our data strongly suggest that RT activity of Pol η is required in error-free DSBR.

59 BASIC BIOLOGICAL SCIENCES↗

Discretization errors in molecular dynamics simulations with deterministic and stochastic thermostats

We investigate the influence of numerical discretization errors on computed averages in a molecular dynamics simulation of TIP4P liquid water at 300 K coupled to different deterministic (Nose-Hoover and Nose-Poincare) and stochastic (Langevin) thermostats. We propose a couple of simple practical approaches to estimating such errors and taking them into account when computing the averages. We show that it is possible to obtain accurate measurements of various system quantities using step sizes of up to 70% of the stability threshold of the integrator, which for the system of TIP4P liquid water at 300 K corresponds to the step size of about 7 fs.

97 MATHEMATICS AND COMPUTING↗

Leveraging interpolation models and error bounds for verifiable scientific machine learning

Effective verification and validation techniques for modern scientific machine learning workflows are challenging to devise. Statistical methods are abundant and easily deployed, but often rely on speculative assumptions about the data and methods involved. Error bounds for classical interpolation techniques can provide mathematically rigorous estimates of accuracy, but often are difficult or impractical to determine computationally. Here, in this work, we present a best-of-both-worlds approach to verifiable scientific machine learning by demonstrating that (1) multiple standard interpolation techniques have informative error bounds that can be computed or estimated efficiently; (2) comparative performance among distinct interpolants can aid in validation goals; (3) deploying interpolation methods on latent spaces generated by deep learning techniques enables some interpretability for black-box models. We present a detailed case study of our approach for predicting lift-drag ratios from airfoil images. Code developed for this work is available in a public Github repository.

97 MATHEMATICS AND COMPUTING↗

Evaluation of Scatter Contribution and Distance Error by Iterative Methods for Strength Determination of HDR {sup 192}Ir Brachytherapy Source

High-dose rate (HDR) {sup 192}Ir brachytherapy sources are commonly used for management of malignancies by brachytherapy applications. Measurement of source strength at the hospital is an important dosimetry requirement. The use of 0.6-cm{sup 3} cylindrical ionization chamber is one of the methods of measuring the source strength at the hospitals because this chamber is readily available for beam calibration and dosimetry. While using the cylindrical chamber for this purpose, it is also required to determine the positioning error of the ionization chamber, with respect to the source, commonly called a distance error (c). The contribution of scatter radiation (M{sub s}) from floor, walls, ceiling, and other materials available in the treatment room also need to be determined accurately so that appropriate correction can be applied while calculating the source strength from the meter reading. Iterative methods of Newton-Raphson and least-squares were used in this work to determine scatter contribution in the experimentally observed meter reading (pC/s) of a cylindrical ionization chamber. Monte Carlo simulation was also used to cross verify the results of the least-squares method. The experimentally observed, least-squares calculated and Monte Carlo estimated values of meter readings from HDR {sup 192}Ir brachytherapy source were in good agreement. Considering procedural simplicity, the method of least-squares is recommended for use at the hospitals to estimate values of f (constant of proportionality), c, and M{sub s} required to determine the strength of HDR {sup 192}Ir brachytherapy sources.

07 ISOTOPE AND RADIATION SOURCES↗

Emittance growth due to random force error

In Refs. Qiang (2019) and Kesting (2015), the authors showed that the emittance growth rate due to the force error of macroparticle sampling will be proportional to the step size of simulation. In this note, we show that for the random force error, the emittance growth rate will be independent of the step size, which is consistent with the simulation observation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗