Search NASA⌕ Search

SEARCH · Search NASA

Results for “Filtering techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Vision-aided Monitoring and Control of Thermal Spray, Spray Forming, and Welding Processes

Vision is one of the most powerful forms of non-contact sensing for monitoring and control of manufacturing processes. However, processes involving an arc plasma or flame such as welding or thermal spraying pose particularly challenging problems to conventional vision sensing and processing techniques. The arc or plasma is not typically limited to a single spectral region and thus cannot be easily filtered out optically. This paper presents an innovative vision sensing system that uses intense stroboscopic illumination to overpower the arc light and produce a video image that is free of arc light or glare and dedicated image processing and analysis schemes that can enhance the video images or extract features of interest and produce quantitative process measures which can be used for process monitoring and control. Results of two SBIR programs sponsored by NASA and DOE and focusing on the application of this innovative vision sensing and processing technology to thermal spraying and welding process monitoring and control are discussed.

Agapakis, John E.↗

NASA Tech Briefs, December 2012

The topics include: Pattern Generator for Bench Test of Digital Boards; 670-GHz Down- and Up-Converting HEMT-Based Mixers; Lidar Electro-Optic Beam Switch with a Liquid Crystal Variable Retarder; Feedback Augmented Sub-Ranging (FASR) Quantizer; Real-Time Distributed Embedded Oscillator Operating Frequency Monitoring; Software Modules for the Proximity-1 Space Link Interleaved Time Synchronization (PITS) Protocol; Description and User Instructions for the Quaternion to Orbit v3 Software; AdapChem; Mars Relay Lander and Orbiter Overflight Profile Estimation; Extended Testability Analysis Tool; Interactive 3D Mars Visualization; Rapid Diagnostics of Onboard Sequences; MER Telemetry Processor; pyam: Python Implementation of YaM; Process for Patterning Indium for Bump Bonding; Archway for Radiation and Micrometeorite Occurrence Resistance; 4D Light Field Imaging System Using Programmable Aperture; Device and Container for Reheating and Sterilization; Radio Frequency Plasma Discharge Lamps for Use as Stable Calibration Light Sources; Membrane Shell Reflector Segment Antenna; High-Speed Transport of Fluid Drops and Solid Particles via Surface Acoustic Waves; Compact Autonomous Hemispheric Vision System; A Distributive, Non-Destructive, Real-Time Approach to Snowpack Monitoring; Wideband Single-Crystal Transducer for Bone Characterization; Numerical Simulation of Rocket Exhaust Interaction With Lunar Soil; Motion Imagery and Robotics Application (MIRA): Standards-Based Robotics; Particle Filtering for Model-Based Anomaly Detection in Sensor Networks; Ka-band Digitally Beamformed Airborne Radar Using SweepSAR Technique; Composite With In Situ Plenums; Multi-Beam Approach for Accelerating Alignment and Calibration of HyspIRI-Like Imaging Spectrometers; JWST Lifting System; Next-Generation Tumbleweed Rover; Pneumatic System for Concentration of Micrometer-Size Lunar Soil.

Source record↗

Origins and mitigation of spurious modes in aluminum nitride microresonators.

Recently reported narrow bandwidth, <;2%, aluminum nitride microresonator filters in the 100-500 MHz range offer lower insertion loss, 100x smaller size, and elimination of large external matching networks, when compared to similar surface acoustic wave filters. While the initial results are promising, many microresonators exhibit spurious responses both close and far from the pass band which degrade the out of band rejection and prevent the synthesis of useful filters. This paper identifies the origins of several unwanted modes in overtone width extensional aluminum nitride microresonators and presents techniques for mitigating the spurious responses.

36 MATERIALS SCIENCE↗

Smoothing by cubic spline modified applied to solve inverse thermal problem

This paper presents an alternative to cubic spline regularization and its weighted form applied in solving inverse thermal problems. The inverse heat transfer problems are classified as ill-posed, that is, the solution may become unstable, mainly because they are sensitive to random errors deriving from the input data, necessitating a regularization method to soften these effects. The smoothing technique proposed by cubic spline regularization ensures that the global data tend to be more stable, with fewer data oscillations and dependent on a single arbitrary parameter input. It also shows that the weighted cubic spline is able to enhance filter action. The methods have been implemented in order for the search engine to optimize the choice of parameters and weight and, thus, the smoothing gains more flexibility and accuracy. The simulated and experimental tests confirm that the techniques are effective in reducing the amplified noise by inverse thermal problem presented.

97 MATHEMATICS AND COMPUTING↗

Method for evaluating bow tie filter angle-dependent attenuation in CT: Theory and simulation results

Purpose: Dosimetry in computed tomography (CT) is increasingly based on Monte Carlo studies that define the dose in the patient (in mGy) as a function of air kerma (free in air) at isocenter (mGy). The accuracy of Monte Carlo studies depends in part on the accuracy of the characterization of the bow tie filter for a given CT scanner model. A simple method for characterizing the bow tie filter attenuation profile in CT scanners would therefore be very useful. The theory behind such a method is proposed. Methods: A measurement protocol is discussed mathematically and demonstrated using computer simulation. The proposed method requires the placement of a radiation monitor at the periphery of the CT field, and the time domain signal (kerma rate versus time) is measured with good temporal resolution ({approx}200 Hz or better) and with all other objects (e.g., patient couch) retracted from the field of view. Knowledge of the source to isocenter distance (or alternately, the isocenter to probe distance) is required. The stationary detector records the kerma rate versus time signal as the gantry rotates through several revolutions. From this temporal data, signal processing techniques are used to extract in-phase peaks, as well as out-of-phase kerma rate levels. From these data, the distance from isocenter to the probe can be determined (or, alternatively, the source to isocenter distance), and the angle-dependent bow tie filter attenuation can be computed. By measuring the angle-dependent bow tie filter attenuation at several kVp settings, the bow tie composition versus fan angle can be computed using basis decomposition techniques. Results: The simulations illustrated that with 2% added noise in the kerma rate versus time signal, the attenuation properties of a hypothetical two component (aluminum and polymethyl methacrylate) bow tie filter could be determined (r{sup 2}>0.99). Although the computed basis material thicknesses were not exactly equal to the actual thicknesses, their combined attenuation factors matched that of the actual filter across kVp's to within an average of 0.057%. Conclusions: It is concluded that the proposed method may provide a simple noninvasive approach to characterizing the performance of bow tie filters in CT systems; however, experimental validation is necessary.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inertial Centrifugal-Based Pre-filter for Spacecraft Life Support Systems

The intrusion of planetary dust inside space vehicles on future Lunar missions may lead to performance compromises of the cabin air-filtration system. The evasive character of the fine planetary dust, in particular lunar dust, could enable the dust to make its way through the seals and barriers of the EVA hatches and become airborne in the cabin. This can result in performance and capacity overload of the high efficiency filter media and particle separation systems. Adequate pre-filtration can substantially reduce the load on the higher efficiency components leading to smaller dust loads during surge and nominal dust loading conditions, thereby protecting and extending the life of these components. A particle separation concept, based on centrifugal separation, is being investigated for its application as a pre-filter. The concept has previously been proposed for application in the aircraft engine industry, as means of capturing corrosive dust and salt deposits that may harm the engine. The technique has the advantages of being passive, integrable to HVAC and space vehicle architecture, and has the potential for high degree of particle separation with proper fluid dynamic design. Computational Fluid Dynamics (CFD) and particle tracing modeling were used to arrive at an initial design for rapid prototyping and testing. If feasible, the concept can be integrated to the Scroll Filter System which is being developed by NASA to address the filtration demands on long during spaceflight and surface missions. This paper will describe the modeling results of this concept.

Life Support Systems↗

Inertial Centrifugal-Based Pre-filter for Spacecraft Life Support Systems

The intrusion of planetary dust inside space vehicles on future Lunar missions may lead to performance compromises of the cabin air-filtration system. The evasive character of the fine planetary dust, in particular lunar dust, could enable the dust to make its way through the seals and barriers of the EVA hatches and become airborne in the cabin. This can result in performance and capacity overload of the high efficiency filter media and particle separation systems. Adequate pre-filtration can substantially reduce the load on the higher efficiency components leading to smaller dust loads during surge and nominal dust loading conditions, thereby protecting and extending the life of these components. A particle separation concept, based on centrifugal separation, is being investigated for its application as a pre-filter. The concept has previously been proposed for application in the aircraft engine industry, as means of capturing corrosive dust and salt deposits that may harm the engine. The technique has the advantages of being passive, integrable to HVAC and space vehicle architecture, and has the potential for high degree of particle separation with proper fluid dynamic design. Computational Fluid Dynamics (CFD) and particle tracing modeling were used to arrive at an initial design for rapid prototyping and testing. If feasible, the concept can be integrated to the Scroll Filter System which is being developed by NASA to address the filtration demands on long during spaceflight and surface missions. This paper will describe the modeling results of this concept.

Life Support Systems↗

iCHORD-SI combination as an alternative to EDS-EBSD coupling for the characterization of γ-γ′ nickel-based superalloy microstructures

Highlights: • A new method to get orientation maps discriminating the gamma and gamma’ phases of Ni superalloys is described. • The method combines the iCHORD technique with secondary ion imaging. • The new method resolves precipitates down to 150 nm within a reasonable acquisition time. - Abstract: Because they exhibit very similar diffraction patterns, the γ and γ′ phases of nickel-based superalloys cannot be distinguished by the conventional EBSD technique alone. This paper presents an original method which discriminates those phases on an orientation map by exploiting their chemical differences. Performed with a Focused Ion Beam (FIB) microscope, the method is the combination of the ion CHanneling ORientation Determination technique (iCHORD) – recently developed by Langlois et al. [1] – with the chemical information obtained from Secondary Ion (SI) images. The performances of the method are compared to the EDS-EBSD coupling which also discriminates phases based on their chemical compositions. Applied filters, angular resolution, spatial resolution of the phase discrimination and acquisition time are discussed. It results that the iCHORD–SI combination offers an orientation map with an angular resolution slightly decreased compared to that of the EBSD technique, but with a good phase resolution (down to 150 nm) and within a reasonable acquisition time. Thus, the iCHORD–SI combination appears to be an interesting method for the crystallographic systems where phases are difficult to discriminate by the EBSD technique alone but present a significant chemical contrast.

36 MATERIALS SCIENCE↗

Ternary behavior and systematic nanoscale manipulation of domain structures in P3HT/PCBM/P3HT-b-PEO films

Nanophase separation plays a critical role in the performance of donor acceptor based organic photovoltaic (OPV) devices. Although post-fabrication annealing is often used to enhance OPV efficiency, the ability to exert precise control over phase separated domains and connectivity remains elusive. In this work, we use a diblock copolymer to systematically manipulate the domain sizes of an organic solar cell active layer at the nanoscale. More specifically, a poly(3-hexylthiophene)-bpoly( ethylene oxide) (P3HT-b-PEO) diblock copolymer with a low polydispersity index (PDI 1.3) is added to a binary blend of P3HT and 6,6-phenyl C61-butyric acid methyl ester (PCBM) at different concentrations (0 20 wt%). Energy-filtered TEM (EFTEM) results suggest systematic changes of P3HT distribution as a function of block copolymer compatibilizer concentration and thermal annealing. X-ray scattering and microscopy techniques are used to show that prior to annealing, active layer domain sizes do not change substantially as compatibilizer is added; however after thermal annealing, the domain sizes are significantly reduced as the amount of P3HT-b-PEO compatibilizer increases. The impact of compatibilizer is further rationalized through quantum density functional theory calculations. Overall, this work demonstrates the possibility of block copolymers to systematically manipulate the nanoscale domain-structure of blends used for organic photovoltaic devices. Furthermore, if coupled with efficient charge transport and collection (through judicious choice of block copolymer type and composition), this approach may contribute to further optimization of OPV devices.

14 SOLAR ENERGY↗

Clinical implementation of a digital tomosynthesis-based seed reconstruction algorithm for intraoperative postimplant dose evaluation in low dose rate prostate brachytherapy

Purpose: The low dose rate brachytherapy procedure would benefit from an intraoperative postimplant dosimetry verification technique to identify possible suboptimal dose coverage and suggest a potential reimplantation. The main objective of this project is to develop an efficient, operator-free, intraoperative seed detection technique using the imaging modalities available in a low dose rate brachytherapy treatment room. Methods: This intraoperative detection allows a complete dosimetry calculation that can be performed right after an I-125 prostate seed implantation, while the patient is still under anesthesia. To accomplish this, a digital tomosynthesis-based algorithm was developed. This automatic filtered reconstruction of the 3D volume requires seven projections acquired over a total angle of 60 deg. with an isocentric imaging system. Results: A phantom study was performed to validate the technique that was used in a retrospective clinical study involving 23 patients. In the patient study, the automatic tomosynthesis-based reconstruction yielded seed detection rates of 96.7% and 2.6% false positives. The seed localization error obtained with a phantom study is 0.4{+-}0.4 mm. The average time needed for reconstruction is below 1 min. The reconstruction algorithm also provides the seed orientation with an uncertainty of 10 deg. {+-}8 deg. The seed detection algorithm presented here is reliable and was efficiently used in the clinic. Conclusions: When combined with an appropriate coregistration technique to identify the organs in the seed coordinate system, this algorithm will offer new possibilities for a next generation of clinical brachytherapy systems.

61 RADIATION PROTECTION AND DOSIMETRY↗

Corner-Cube Retroreflector Instrument for Advanced Lunar Laser Ranging

A paper describes how, based on a structural-thermal-optical-performance analysis, it has been determined that a single, large, hollow corner cube (170- mm outer diameter) with custom dihedral angles offers a return signal comparable to the Apollo 11 and 14 solid-corner-cube arrays (each consisting of 100 small, solid corner cubes), with negligible pulse spread and much lower mass. The design of the corner cube, and its surrounding mounting and casing, is driven by the thermal environment on the lunar surface, which is subject to significant temperature variations (in the range between 70 and 390 K). Therefore, the corner cube is enclosed in an insulated container open at one end; a narrow-bandpass solar filter is used to reduce the solar energy that enters the open end during the lunar day, achieving a nearly uniform temperature inside the container. Also, the materials and adhesive techniques that will be used for this corner-cube reflector must have appropriate thermal and mechanical characteristics (e.g., silica or beryllium for the cube and aluminum for the casing) to further reduce the impact of the thermal environment on the instrument's performance. The instrument would consist of a single, open corner cube protected by a separate solar filter, and mounted in a cylindrical or spherical case. A major goal in the design of a new lunar ranging system is a measurement accuracy improvement to better than 1 mm by reducing the pulse spread due to orientation. While achieving this goal, it was desired to keep the intensity of the return beam at least as bright as the Apollo 100-corner-cube arrays. These goals are met in this design by increasing the optical aperture of a single corner cube to approximately 170 mm outer diameter. This use of an "open" corner cube allows the selection of corner cube materials to be based primarily on thermal considerations, with no requirements on optical transparency. Such a corner cube also allows for easier pointing requirements, because there is no dependence on total internal reflection, which can fail off-axis.

Turyshev, Slava G.↗

TL/OSL properties of beta irradiated Al2O3:Tm3+ phosphor synthesized by microwave combustion method

Highlights: • TL emission spectra of γ – rayed Al{sub 2}O{sub 3}:Tm{sup 3+} shows Tm{sup 3+} characteristic transitions. • Doping of Tm{sup 3+} ions causes enhancement of TL/OSL. • TL/OSL kinetic parameters are analyzed by CGCD method. • TL mechanism of γ/β – rayed Al{sub 2}O{sub 3}:Tm{sup 3+} was proposed. • TL/OSL dosimetric properties of Al{sub 2}O{sub 3}:Tm{sup 3+} suggests that the material is appropriate for medical dosimetry. - Abstract: This work discusses synthesis of stable α-phase of Al{sub 2}O{sub 3}:Tm{sup 3+} by combustion method using temperature controlled microwave oven. The crystalline phase was analyzed by X-ray diffraction (XRD) technique and average crystallite size was found to be 147 nm. Observations using scanning electron microscope (SEM) image suggest formation of agglomerated particles and energy dispersive x-ray spectroscopy (EDS) confirmed the incorporation of Tm{sup 3+} in Al{sub 2}O{sub 3}. Thermoluminescence emission (TLE) spectrum of γ – irradiated Al{sub 2}O{sub 3}:Tm{sup 3+} shows characteristic emissions of Tm{sup 3+}, Cr{sup 3+} and Mn{sup 4+}. TL glow curves of γ – irradiated Al{sub 2}O{sub 3}:Tm{sup 3+} exhibit a prominent peak at 453 K along with a shoulder at 496 K. The glow curves of β – irradiated Al{sub 2}O{sub 3}:Tm{sup 3+} were studied in different emission regions using U340 + BG39 (UV band pass), CS759 + BG39 (Blue band pass) and BG39 (Visible band pass) optical glass filters. A prominent peak was observed at 471 K in for all mentioned emission regions and an additional shoulder was observed at 511 K with CS759 + BG39 and BG39 filters. TL glow curve of β – irradiated Al{sub 2}O{sub 3}:Tm{sup 3+} using only BG39 filter had more counts than CS759 + BG39 and U340 + BG39 filters. Further, the effect of Tm{sup 3+} impurity on TL response was studied. TL kinetic parameters were estimated by using computerized glow curve deconvolution (CGCD) technique. The activation energy and frequency factor of prominent peak (471 K) were found to be 1.31 eV and 3.50 × 10{sup 13} s{sup −1} respectively. Optically stimulated luminescence (OSL) characteristics of β – irradiated Al{sub 2}O{sub 3}:Tm{sup 3+} were studied using U340 + BG39 and CS759 + BG39 filters. Highest OSL intensity was observed in UV. OSL curves were deconvoluted by general order decay equation. Life time and photoionization cross section of the traps responsible for OSL were found to be 5.30 s and 3.98 × 10{sup −18} cm{sup 2} respectively. The process of ionization of electron from Tm{sup 3+}, electron trap in host lattice and its recombination mechanism is proposed. Phosphorescence decay of beta irradiated sample was also studied. The lifetime of phosphorescence decay was found to be 140 s for the prominent peak and TL intensity decays 25% after the phosphorescence. TL/OSL dosimetric properties viz. linearity with dose, reusability and minimum detectable dose of the phosphor were characterized for medical dosimetry application.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The SRT reconstruction algorithm for semiquantification in PET imaging

Purpose: The spline reconstruction technique (SRT) is a new, fast algorithm based on a novel numerical implementation of an analytic representation of the inverse Radon transform. The mathematical details of this algorithm and comparisons with filtered backprojection were presented earlier in the literature. In this study, the authors present a comparison between SRT and the ordered-subsets expectation–maximization (OSEM) algorithm for determining contrast and semiquantitative indices of {sup 18}F-FDG uptake. Methods: The authors implemented SRT in the software for tomographic image reconstruction (STIR) open-source platform and evaluated this technique using simulated and real sinograms obtained from the GE Discovery ST positron emission tomography/computer tomography scanner. All simulations and reconstructions were performed in STIR. For OSEM, the authors used the clinical protocol of their scanner, namely, 21 subsets and two iterations. The authors also examined images at one, four, six, and ten iterations. For the simulation studies, the authors analyzed an image-quality phantom with cold and hot lesions. Two different versions of the phantom were employed at two different hot-sphere lesion-to-background ratios (LBRs), namely, 2:1 and 4:1. For each noiseless sinogram, 20 Poisson realizations were created at five different noise levels. In addition to making visual comparisons of the reconstructed images, the authors determined contrast and bias as a function of the background image roughness (IR). For the real-data studies, sinograms of an image-quality phantom simulating the human torso were employed. The authors determined contrast and LBR as a function of the background IR. Finally, the authors present plots of contrast as a function of IR after smoothing each reconstructed image with Gaussian filters of six different sizes. Statistical significance was determined by employing the Wilcoxon rank-sum test. Results: In both simulated and real studies, SRT exhibits higher contrast and lower bias than OSEM at the cold lesions. This improvement is achieved at the expense of increasing the noise in the reconstructed images. For the hot lesions, SRT exhibits a small improvement in contrast and LBR over OSEM with 21 subsets and two iterations; however, this improvement is not statistically significant. As the number of iterations increases, the performance of OSEM improves over SRT but again without statistical significance. The curves of contrast and LBR as a function of IR after Gaussian blurring indicate that the advantage of SRT in the cold regions is maintained even after decreasing the noise level by Gaussian blurring. Conclusions: SRT, at the expense of slightly increased noise in the reconstructed images, reconstructs images of higher contrast and lower bias than the clinical protocol of OSEM. This improvement is particularly evident for images involving cold regions. Thus, it appears that SRT should be particularly useful for the quantification of low-count and cold regions.

60 APPLIED LIFE SCIENCES↗

An experimental modal testing/identification technique for personal computers

A PC-based system for mode shape identification is evaluated. A time-domain modal identification procedure is utilized to identify the mode shapes of a beam apparatus from discrete time-domain measurements. The apparatus includes a cantilevered aluminum beam, four accelerometers, four low-pass filters, and the computer. The method's algorithm is comprised of an identification algorithm: the Eigensystem Realization Algorithm (ERA) and an estimation algorithm called Minimum Model Error (MME). The identification ability of this algorithm is compared with ERA alone, a frequency-response-function technique, and an Euler-Bernoulli beam model. Detection of modal parameters and mode shapes by the PC-based time-domain system is shown to be accurate in an application with an aluminum beam, while mode shapes identified by the frequency-domain technique are not as accurate as predicted. The new method is shown to be significantly less sensitive to noise and poorly excited modes than other leading methods. The results support the use of time-domain identification systems for mode shape prediction.

Roemer, Michael J.↗

Rapid, all-optical crystal orientation imaging of two-dimensional transition metal dichalcogenide monolayers

Two-dimensional (2D) atomic materials such as graphene and transition metal dichalcogenides (TMDCs) have attracted significant research and industrial interest for their electronic, optical, mechanical, and thermal properties. While large-area crystal growth techniques such as chemical vapor deposition have been demonstrated, the presence of grain boundaries and orientation of grains arising in such growths substantially affect the physical properties of the materials. There is currently no scalable characterization method for determining these boundaries and orientations over a large sample area. We here present a second-harmonic generation based microscopy technique for rapidly mapping grain orientations and boundaries of 2D TMDCs. We experimentally demonstrate the capability to map large samples to an angular resolution of ±1° with minimal sample preparation and without involved analysis. A direct comparison of the all-optical grain orientation maps against results obtained by diffraction-filtered dark-field transmission electron microscopy plus selected-area electron diffraction on identical TMDC samples is provided. This rapid and accurate tool should enable large-area characterization of TMDC samples for expedited studies of grain boundary effects and the efficient characterization of industrial-scale production techniques.

36 MATERIALS SCIENCE↗

An approach based on dwindling filter method for positive definite generalized eigenvalue problem

In this paper, we present a new spectral residual method for solving large-scale positive definite generalized eigenvalue problems. The proposed algorithm is equipped with a dwindling multidimensional nonmonotone filter, in which the envelope dwindles as the step length decreases. We have also employed a relaxed nonmonotone line search technique in the structure of the algorithm which allows it to enjoy the nonmonotonicity from scratch. Under some mild and standard assumptions, the global convergence property of the proposed algorithm is established. An implementation of the new algorithm on some test problems shows the efficiency and effectiveness of the proposed algorithm in practice.

97 MATHEMATICS AND COMPUTING↗