Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image analysis.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98

Two-dimensional wave-number spectral analysis techniques for phase contrast imaging turbulence imaging data on large helical device

An analysis method for unfolding the spatially resolved wave-number spectrum and phase velocity from the 2D CO{sub 2} laser phase contrast imaging system on the large helical device is described. This is based on the magnetic shear technique which identifies propagation direction from 2D spatial Fourier analysis of images detected by a 6 × 8 detector array. Because the strongest modes have wave-number at the lower end of the instrumental k range, high resolution spectral techniques are necessary to clearly resolve the propagation direction and hence the spatial distribution of fluctuations along the probing laser beam. Multiple-spatial point cross-correlation averaging is applied before calculating the spatial power spectrum. Different methods are compared, and it is found that the maximum entropy method (MEM) gives best results. The possible generation of artifacts from the over-narrowing of spectra are investigated and found not to be a significant problem. The spatial resolution Δρ (normalized radius) around the peak wave-number, for conventional Fourier analysis, is ∼0.5, making physical interpretation difficult, while for MEM, Δρ ∼ 0.1.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of radar imaging system parameters for geological analysis

The use of radar image simulation to model terrain variation and determine optimum sensor parameters for geological analysis is described. Optimum incidence angle is determined by the simulation, which evaluates separately the discrimination of surface features possible due to terrain geometry and that due to terrain scattering. Depending on the relative relief, slope, and scattering cross section, optimum incidence angle may vary from 20 to 80 degrees. Large incident angle imagery (more than 60 deg) is best for the widest range of geological applications, but in many cases these large angles cannot be achieved by satellite systems. Low relief regions require low incidence angles (less than 30 deg), so a satellite system serving a broad range of applications should have at least two selectable angles of incidence.

Waite, W. P.↗

X-ray phase contrast imaging of the breast: Analysis of tissue simulating materials

Purpose: Phase contrast imaging, particularly of the breast, is being actively investigated. The purpose of this work is to investigate the x-ray phase contrast properties of breast tissues and commonly used breast tissue substitutes or phantom materials with an aim of determining the phantom materials best representative of breast tissues. Methods: Elemental compositions of breast tissues including adipose, fibroglandular, and skin were used to determine the refractive index, n= 1 -{delta}+i {beta}. The real part of the refractive index, specifically the refractive index decrement ({delta}), over the energy range of 5-50 keV were determined using XOP software (version 2.3, European Synchrotron Radiation Facility, France). Calcium oxalate and calcium hydroxyapatite were considered to represent the material compositions of microcalcifications in vivo. Nineteen tissue substitutes were considered as possible candidates to represent adipose tissue, fibroglandular tissue and skin, and four phantom materials were considered as possible candidates to represent microcalcifications. For each material, either the molecular formula, if available, or the elemental composition based on weight fraction, was used to determine {delta}. At each x-ray photon energy, the absolute percent difference in {delta} between the breast tissue and the substitute material was determined, from which three candidates were selected. From these candidate tissue substitutes, the material that minimized the absolute percent difference in linear attenuation coefficient {mu}, and hence {beta}, was considered to be best representative of that breast tissue. Results: Over the energy range of 5-50 keV, while the {delta} of CB3 and fibroglandular tissue-equivalent material were within 1% of that of fibroglandular tissue, the {mu} of fibroglandular tissue-equivalent material better approximated the fibroglandular tissue. While the {delta} of BR10 and adipose tissue-equivalent material were within 1% of that of adipose tissue, the tissue-equivalent material better approximated the adipose tissue in terms of {mu}. Polymethyl methacrylate, a commonly used tissue substitute, exhibited {delta} greater than fibroglandular tissue by {approx}12%. The A-150 plastic closely approximated the skin. Several materials exhibited {delta} between that of adipose and fibroglandular tissue. However, there was an energy-dependent mismatch in terms of equivalent fibroglandular weight fraction between {delta} and {mu} for these materials. For microcalcifications, aluminum and calcium carbonate were observed to straddle the {delta} and {mu} of calcium oxalate and calcium hydroxyapatite. Aluminum oxide, commonly used to represent microcalcifications in the American College of Radiology recommended phantoms for accreditation exhibited {delta} greater than calcium hydroxyapatite by {approx}23%. Conclusions: A breast phantom comprising A-150 plastic to represent the skin, commercially available adipose and fibroglandular tissue-equivalent formulations to represent adipose and fibroglandular tissue, respectively, was found to be best suited for x-ray phase-sensitive imaging of the breast. Calcium carbonate or aluminum can be used to represent microcalcifications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

APPL Hyperspectral_Imaging_Dataset_for_Heritability_Analysis_in_Populus_trichocarpa

This dataset contains hyperspectral imaging data collected at the Advanced Plant Phenotyping Laboratory (APPL) at Oak Ridge National Laboratory. Natural variants of Populus trichocarpa were imaged using a high-throughput hyperspectral phenotyping pipeline to quantify spectral reflectance traits for downstream quantitative genetics analyses. The dataset includes hyperspectral image files and derived reflectance data products suitable for extracting spectral features across the measured wavelength range (e.g., VNIR and/or SWIR, depending on instrument configuration), along with associated sample metadata (e.g., genotype identifiers, experimental design factors, and imaging run identifiers). These data were generated to support analyses of broad-sense heritability of hyperspectral traits and their relationships with biochemical phenotypes (including lignin traits from Py-MBMS).

APPL↗

Assessing pore network heterogeneity across multiple scales to inform CO2 injection models

Geologic heterogeneity is a key feature that must be considered when translations of scaled data are performed. This paper presents the assessment of geologic heterogeneity using a multiscale workflow that includes image analysis-based methods coupled with well log analysis to provide data in which fractals and machine learning methods estimate the carbon dioxide (CO 2 ) storage resource potential of a reservoir. The heterogeneity of rock properties of the complex Bell Creek reservoir in Montana, USA, was explored at the pore scale (~nm to mm), core scale (~mm to m), and well scale (~cm to m). The data used in this study included advanced image analysis of micro-CT (computed tomography) images (pore scale), thin sections (pore scale), plugs and core images (core scale) and well logs (well scale). The micro-CT images were segmented using a U-net segmentation approach into objects of pores and grains. Further, the segmented images were reconstructed into subvolumes of different sizes. Physical properties (porosity and permeability) and fractal dimensions were calculated for the various subvolumes, and Lorenz coefficient (Lc) values, a single parameter to describe the degree of heterogeneity within a pay zone section, were calculated from thin-section images and well logs. Porosity and fractal dimension values were used to estimate the 188-µm threshold of representative elementary volume (REV) in this study. Both the Lc and fractal dimension values were found to be negatively correlated. When these two parameters are combined, it is possible to discern differences in the complex porous networks of the samples analyzed in this study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Throughput Microfluidics Platform for Intracellular Delivery and Sampling of Biomolecules from Live Cells

Nondestructive cell membrane permeabilization systems enable the intracellular delivery of exogenous biomolecules for cell engineering tasks as well as the temporal sampling of cytosolic contents from live cells for the analysis of dynamic processes. Here, in this paper, we report a microwell array format live-cell analysis device (LCAD) that can perform localized-electroporation induced membrane permeabilization, for cellular delivery or sampling, and directly interfaces with surface-based biosensors for analyzing the extracted contents. We demonstrate the capabilities of the LCAD via an automated high-throughput workflow for multimodal analysis of live-cell dynamics, consisting of quantitative measurements of enzyme activity using self-assembled monolayers for MALDI mass spectrometry (SAMDI) and deep-learning enhanced imaging and analysis. By combining a fabrication protocol that enables robust assembly and operation of multilayer devices with embedded gold electrodes and an automated imaging workflow, we successfully deliver functional molecules (plasmid and siRNA) into live cells at multiple time-points and track their effect on gene expression and cell morphology temporally. Furthermore, we report sampling performance enhancements, achieving saturation levels of protein tyrosine phosphatase activity measured from as few as 60 cells, and demonstrate control over the amount of sampled contents by optimization of electroporation parameters using a lumped model. Lastly, we investigate the implications of cell morphology on electroporation-induced sampling of fluorescent molecules using a deep-learning enhanced image analysis workflow.

59 BASIC BIOLOGICAL SCIENCES↗

LLM integration into EPICS

The utilization of large language models (LLMs) such as ChatGPT has seen a remarkable increase in various fields over the past few years. These models have demonstrated their versatility and capability in understanding and generating human-like text, making them invaluable tools in numerous applications. In this project, we explore the integration of a LLM into the Experimental Physics and Industrial Control System (EPICS). The primary focus of this integration is to employ the LLM for advanced image processing and spatial analysis on images obtained from the beamlines. By leveraging the capabilities of the LLM, we aim to enhance the accuracy and efficiency of image interpretation, enabling more precise data analysis and decision-making within the EPICS framework. This integration not only showcases the potential of LLMs in scientific and industrial applications but also sets the stage for future advancements in automated control systems.

Adams, Ethan↗

Image-Driven Hybrid Structural Analysis Based on Continuum Point Cloud Method with Boundary Capturing Technique

Conventional approaches for the structural health monitoring of infrastructures often rely on physical sensors or targets attached to structural members, which require considerable preparation, maintenance, and operational effort, including continuous on-site adjustments. This paper presents an image-driven hybrid structural analysis technique that combines digital image processing (DIP) and regression analysis with a continuum point cloud method (CPCM) built on a particle-based strong formulation. Polynomial regressions capture the boundary shape change due to the structural loading and precisely identify the edge and corner coordinates of the deformed structure. The captured edge profiles are transformed into essential boundary conditions. This allows the construction of a strongly formulated boundary value problem (BVP), classified as the Dirichlet problem. Capturing boundary conditions from the digital image is novel, although a similar approach was applied to the point cloud data. It was shown that the CPCM is more efficient in this hybrid simulation framework than the weak-form-based numerical schemes. Unlike the finite element method (FEM), it can avoid aligning boundary nodes with regression points. A three-point bending test of a rubber beam was simulated to validate the developed technique. The simulation results were benchmarked against numerical results by ANSYS and various relevant numerical schemes. The technique can effectively solve the Dirichlet-type BVP, yielding accurate deformation, stress, and strain values across the entire problem domain when employing a linear strain model and increasing the number of CPCM nodes. In addition, comparative analysis with conventional displacement tracking techniques verifies the developed technique’s robustness. The proposed technique effectively circumvents the inherent limitations of traditional monitoring methods resulting from the reliance on physical gauges or target markers so that a robust and non-contact solution for remote structural health monitoring in real-scale infrastructures can be provided, even in unfavorable experimental environments.

Chemistry↗

Plasmaspheric Density Troughs: Global IMAGE EUV Observations and Analysis via Global Core Plasma Modeling

To date, the IMAGE EUV camera has observed several plasmaspheric density trough features inside the plasmapause under a wide range of geomagnetic activity. From the perspective of EUV, a density trough feature appears as a channel of diminished pixel counts which spans a width of L-shell (DELTA L) and magnetic local time (MLT) inside the plasmapause. Plasmaspheric density troughs are found to be morphologically complex possessing considerable spatial and temporal variability. We present an analysis of the evolution of trough DELTA L and MLT extent as functions of associated D (sub ST) and K (sub p) history. Trough features range in size from 0.16 less than or equal to DELTA L less than or equal to 1.2 with azimuthal extent from 1500 less than or equal to MLT less than or equal to 1200. All cases of plasmaspheric density troughs studied to date appear to have evolved as a result of the inner edge of the afternoon/evening plasma drainage plume being wrapped around through the nightside plasmasphere. The structure of plasmaspheric density trough features is further probed by analyzing simulated EUV images produced by forward modeling artificially introduced regions of depleted density into both static and dynamic global core plasmaspheric models. Forward modeling suggests that (1) L-shell refilling of density troughs during storm recovery can be modeled as filling from the ionosphere toward the equator (i.e., bottom-up refilling), and (2) that an erosion process is operating within flux tubes beyond the outer L-shell wall of the observed density troughs.

Adrian, M. L.↗

Recovery of atmospheric water vapor total column abundance from imaging spectrometer data around 940 nm - Sensitivity analysis and application to Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data

Two simple techniques (Continuum Interpolated Band Ratio, CIBR, and Narrow/Wide ratio, N/W) to retrieve path precipitable water from AVIRIS high spectral resolution radiance data using the 940 nm water absorption band are compared. A sensitivity analysis was performed using the radiative transfer code LOWTRAN 7 to determine which one of these two approaches will provide a better estimate over land and water areas. The CIBR proved to be the technique less sensitive to perturbing effects, except for errors in visibility estimate. Both techniques were applied to AVIRIS radiance data acquired over Salton Sea, California. Resulting images confirmed that the use of a constant gray reflectance in the model led to a higher overestimation of the amount of water retrieved for N/W over vegetated areas. Validation was performed through comparison between an independent estimate of water vapor from concurrent Reagan sunphotometer measurements and AVIRIS estimates. Amounts retrieved using the N/W approach match more closely in situ measurements, even after adjusting model parameters for background reflectance, viewing geometry, and type of aerosol at the site.

Carrere, Veronique↗

Imaging for dismantlement verification: information management and analysis algorithms

The level of detail discernible in imaging techniques has generally excluded them from consideration as verification tools in inspection regimes. An image will almost certainly contain highly sensitive information, and storing a comparison image will almost certainly violate a cardinal principle of information barriers: that no sensitive information be stored in the system. To overcome this problem, some features of the image might be reduced to a few parameters suitable for definition as an attribute, which must be non-sensitive to be acceptable in an Information Barrier regime. However, this process must be performed with care. Features like the perimeter, area, and intensity of an object, for example, might reveal sensitive information. Any data-reduction technique must provide sufficient information to discriminate a real object from a spoofed or incorrect one, while avoiding disclosure (or storage) of any sensitive object qualities. Ultimately, algorithms are intended to provide only a yes/no response verifying the presence of features in the image. We discuss the utility of imaging for arms control applications and present three image-based verification algorithms in this context. The algorithms reduce full image information to non-sensitive feature information, in a process that is intended to enable verification while eliminating the possibility of image reconstruction. The underlying images can be highly detailed, since they are dynamically generated behind an information barrier. We consider the use of active (conventional) radiography alone and in tandem with passive (auto) radiography. We study these algorithms in terms of technical performance in image analysis and application to an information barrier scheme.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Hyperspectral X-ray Imaging: Progress Towards Chemical Analysis in the SEM

The Hyperspectral X-ray Imaging (HXI) project will enable non-destructive chemical-state determination of nano-scale samples in the electron microscope for nuclear safeguards applications. To efficiently measure chemical state through electron-excited X-ray emission requires a combination of wide spectral bandwidth, high resolution, and high count rate capability. We are building a next-generation X-ray detector based on an array of transition edge sensors (TESs) to make these measurements possible and routine in the scanning electron microscope (SEM). Leveraging the large pixel densities afforded by microwave multiplexing readout and continuous, uninterrupted operation of a cryogen-free dilution refrigerator, this instrument will have efficiency to allow chemical species identification of nano-scale samples in hours instead of days to weeks. We describe prototype pixel designs for this HXI instrument, comprising three pixel types that will make up the hybrid TES array. Engineering design of the integrated HXI cryostat and SEM system is in progress, with full detector commissioning expected in Spring 2021 followed closely by full-scale integration with the SEM. Furthermore, we also report on the commissioning of a complementary TES-based X-ray emission spectroscopy platform for bulk samples to build a spectral library for HXI sample identification.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

PIV/BOS synthetic image generation in variable density environments for error analysis and experiment design

In this work, we present an image generation methodology based on ray tracing that can be used to render realistic images of Particle Image Velocimetry (PIV) and Background Oriented Schlieren (BOS) experiments in the presence of density/refractive index gradients. This methodology enables the simulation of aero-thermodynamics experiments for experiment design, error, and uncertainty analysis. Images are generated by emanating light rays from the particles or dot pattern, and propagating them through the density gradient field and the optical elements, up to the camera sensor. The rendered images are realistic, and can replicate the features of a given experimental setup, like optical aberrations and perspective effects, which can be deliberately introduced for error analysis. We demonstrate this methodology by simulating a BOS experiment with a known density field obtained from direct numerical simulations (DNS) of homogeneous buoyancy driven turbulence, and comparing the light ray displacements from ray tracing to results from BOS theory. The light ray displacements show good agreement with the reference data. This methodology provides a framework for further development of simulation tools for use in experiment design and development of image analysis tools for PIV and BOS applications. Finally, an implementation of the proposed methodology in a Python-CUDA program is made available as an open source software for researchers.

47 OTHER INSTRUMENTATION↗

Automated Morphological and Morphometric Analysis of Mass Spectrometry Imaging Data: Application to Biomarker Discovery

Mass spectrometry imaging datasets are mostly analyzed in terms of average intensity in regions of interest. However, biological tissues have different morphologies with several sizes, shapes, and structures. The important biological information, contained in this highly heterogeneous cellular organization, could be hidden by analyzing the average intensities. Finding an analytical process of morphology would help to find such information, describe tissue model, and support identification of biomarkers. This study describes an informatics approach for the extraction and identification of mass spectrometry image features and its application to sample analysis and modeling. For the proof of concept, two different tissue types (healthy kidney and CT-26 xenograft tumor tissues) were imaged and analyzed. A mouse kidney model and tumor model were generated using morphometric – number of objects and total surface – information. The morphometric information was used to identify m/z that have a heterogeneous distribution. It seems to be a worthwhile pursuit as clonal heterogeneity in a tumor is of clinical relevance. This study provides a new approach to find biomarker or support tissue classification with more information. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermostructural Analysis of the SOFIA Fine Field and Wide Field Imagers Subjected to Convective Thermal Shock

The Stratospheric Observatory For Infrared Astronomy (SOFIA) is a highly modified Boeing 747-SP with a 17- ton infrared telescope installed in the aft portion of the aircraft. Unlike ground- and space-based platforms, SOFIA can deploy to make observations anytime, anywhere, in the world. The originally designed aircraft configuration included a ground pre-cool system, however, due to various factors in the history of the project, that system was not installed. This lack of ground pre-cooling was the source of the concern about whether or not the imagers would be exposed to a potentially unsafe thermostructural environment. This concern was in addition to the already-existing concern of some project members that the air temperature rate of change during flight (both at the same altitude as well as ascent or descent) could cause the imagers to be exposed to an unsafe thermostructural environment. Four optical components were identified as the components of concern: two of higher concern (one in each imager), and two of lower concern (one in each imager). The analysis effort began by analyzing one component, after which the analyses for the other components was deemed unnecessary. The purpose of this report is to document these findings as well as lessons learned from the effort.

Kostyk, Christopher B.↗

Poster — Thur Eve — 44: Linearization of Compartmental Models for More Robust Estimates of Regional Hemodynamic, Metabolic and Functional Parameters using DCE-CT/PET Imaging

Quantitative analysis of dynamic positron emission tomography (PET) data usually involves minimizing a cost function with nonlinear regression, wherein the choice of starting parameter values and the presence of local minima affect the bias and variability of the estimated kinetic parameters. These nonlinear methods can also require lengthy computation time, making them unsuitable for use in clinical settings. Kinetic modeling of PET aims to estimate the rate parameter k{sub 3}, which is the binding affinity of the tracer to a biological process of interest and is highly susceptible to noise inherent in PET image acquisition. We have developed linearized kinetic models for kinetic analysis of dynamic contrast enhanced computed tomography (DCE-CT)/PET imaging, including a 2-compartment model for DCE-CT and a 3-compartment model for PET. Use of kinetic parameters estimated from DCE-CT can stabilize the kinetic analysis of dynamic PET data, allowing for more robust estimation of k{sub 3}. Furthermore, these linearized models are solved with a non-negative least squares algorithm and together they provide other advantages including: 1) only one possible solution and they do not require a choice of starting parameter values, 2) parameter estimates are comparable in accuracy to those from nonlinear models, 3) significantly reduced computational time. Our simulated data show that when blood volume and permeability are estimated with DCE-CT, the bias of k{sub 3} estimation with our linearized model is 1.97 ± 38.5% for 1,000 runs with a signal-to-noise ratio of 10. In summary, we have developed a computationally efficient technique for accurate estimation of k{sub 3} from noisy dynamic PET data.

60 APPLIED LIFE SCIENCES↗