CTL Plant Operation with Bituminous Coal Feed

Inputs and outputs for Fischer-Tropsch diesel (FTD) production by a 50,000 barrel per day BTL plant using Illinois No. 6 bituminous coal feed. Includes scenarios for CCS and ATR (autothermal reforming). Naphtha is a co-product of all CTL cases. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=8BCFE720-8B54-4140-AA92-AC56B346268F

01 COAL, LIGNITE, AND PEAT↗

CTL, CBTL, BTL Plant, Construction

Quantifies the amount of materials needed to construct an individual CTL, CBTL, or BTL plant. Data based on construction of an IGCC plant. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=68173453-5BC9-4F0F-88D3-017FCDE9411D

01 COAL, LIGNITE, AND PEAT↗

EXPC Plant CCS Retrofit, Construction

Material inputs for retrofitting an existing pulverized coal (EXPC) power plant with carbon capture and sequestration (CCS). To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=03FD6C0E-5DA6-4455-9374-78A247D946BB

01 COAL, LIGNITE, AND PEAT↗

Marine Coal Terminal

The air emissions from processing coal at a marine bulk terminal. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=B7799731-0A80-43E8-A3FB-DE7338CD6422

01 COAL, LIGNITE, AND PEAT↗

Operation of baseline IGCC plant

The operations of the Integrated Gasification Combined Cycle (IGCC) with or without carbon capture and sequestration (CCS) on the basis of 1 MWh electricity output. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=FA2BC628-088D-45AF-B709-782A88DAEC94

01 COAL, LIGNITE, AND PEAT↗

Operation of Existing Pulverized Coal Power Plant

The operations of an existing pulverized coal (EXPC) power plant with or without carbon capture and sequestration (CCS) on the basis of 1MWh electricity output. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=4EDA9298-2B77-4320-B48E-DEE007352794

01 COAL, LIGNITE, AND PEAT↗

Operation of NETL Baseline SCPC Power Plant

The operations of the NETL baseline Supercritical Pulverized Coal (SCPC) power plants with or without carbon capture and sequestration (CCS) on the basis of 1 MWh electricity output. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=B5A2EB6F-4FBC-4883-922C-BE720FAC5A80

01 COAL, LIGNITE, AND PEAT↗

Operation of NETL Baseline SubCPC Power Plant

The operations of the NETL baseline Subcritical Pulverized Coal (SubCPC) power plants with or without carbon capture and sequestration (CCS) on the basis of 1 MWh electricity output. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=726C064C-F978-49EB-931C-5F69AD92BD5C

01 COAL, LIGNITE, AND PEAT↗

ORV CBTL Plant Operation Princeton

Feedstocks, products, and CO2 emissions for operation of a coal and biomass to liquids plant from report Strategies for Production of Alternative Jet Fuel in the Ohio River Valley. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=EDC49FC1-E81B-41CD-BDE5-069A69F31FEF

01 COAL, LIGNITE, AND PEAT↗

SCPC Power Plant, Construction

Material input for the construction of the NETL baseline supercritical pulverized coal (SCPC) plant with or without carbon capture and sequestration (CCS). To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=404A3685-9CEF-4095-91EB-44CCF08D24F4

01 COAL, LIGNITE, AND PEAT↗

Shuttle Car Construction

The amount of steel used in the construction of one shuttle car to be used to haul coal from the working mine face to the conveyor belt in underground mining. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=551741C7-6DA8-4A7A-822B-0991D7FEDC79

01 COAL, LIGNITE, AND PEAT↗

SOFC NG and Coal plant with CCUS

Coal integrated gasification solid oxide fuel cell (SOFC) and natural gas (NG) solid fuel cell power plants with and without carbon capture. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=85E9192F-26A2-4A05-914B-9AB64C68538D

01 COAL, LIGNITE, AND PEAT↗

Syngergistic Production of Transport Fuels from Coal

Coal-to-liquids (CTL) synthesis using Illinois No. 6 coal via dedicated Fischer-Tropsch facilities or with (F-T) integration with an Integrated Gasification Combined Cycle power plant. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=1BA4D60E-CEF1-4AE3-9CE2-B6C5D6D1CEDF

01 COAL, LIGNITE, AND PEAT↗

Ventilation Energy for Underground Mine

The amount of electricity required to ventilate an underground coal mine. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=1C16842F-D22F-4C79-B4A4-5423557721F3

01 COAL, LIGNITE, AND PEAT↗

Coal Cleaning

The amount of electricity required to power equipment used for cleaning coal at underground and surface mines as well as accounting for coal loss during production activities. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=331FDD97-44BC-41E6-9A95-1E7ECB935098

01 COAL, LIGNITE, AND PEAT↗

Raman Spectroscopy for the On-Line Analysis of Oxidation States of Oxygen Carrier Particles (Final Report)

The need for cleaner energy systems, including CO 2 capture technologies, is driving the current development of chemical looping technologies such as chemical looping combustion (CLC) and chemical looping gasification (CLG). Specific processes that are under development for using solid fuels are in-situ Gasification Chemical-Looping Combustion (iG-CLC) and Chemical Looping with Oxygen Uncoupling (CLOU). Chemical looping is based on using oxygen carriers (e.g., iron oxides, copper oxides, calcium sulfates, etc.) to provide the oxygen for the reaction with the fuel. In order to optimize the overall process performance, it is critical that the properties of the oxygen carriers are well-defined and maintained for their specific purpose during the different stages of the CLC process. One of the critical properties of the oxygen carrier is its oxidation state (e.g., content of Fe 2 O 3 vs. Fe 3 O 4 ) as it affects the fundamental operation of the CLC process. Unfortunately, the ability to make on-line measurements of the oxidation state of oxygen carriers is lacking and new sensors need to be developed. The goal of this project was to evaluate the potential of Raman spectroscopy as a sensor for the on-line analysis of the oxidation state of oxygen carrier particles. Oxygen carrier particles (OCPs) of interest include iron oxides, copper oxides, calcium sulfite, and calcium sulfate, with particle sizes typically less than 0.5 mm diameter. The expected operating conditions of the sensor include OCP temperatures in the range of 800 °C to 1000 °C, and pressures of about 10 atm. We evaluated continuous wave (cw), Quasi cw, pulsed, and time-gated Raman spectroscopy at multiple wavelengths (355 nm, 360 nm, 532 nm, 633 nm, 785 nm). Samples included iron oxides, copper oxides, calcium sulfate, and a custom sample provided by NETL for temperatures beyond 1000 °C. Our findings can be summarized as follows: Calcium sulfate can be detected via cw and pulsed 532 nm Raman spectroscopy at temperatures above 1100 °C.; Hematite (Fe 2 O 3 ) Raman spectra can be detected at temperatures of 700 °C via cw 360 nm, 1089 °C with cw 532 nm, 400 °C with cw 633 and 600 °C with cw 785 nm lasers; Magnetite (Fe 3 O 4 ) can be detected via cw 532 nm Raman spectroscopy up to 600 °C; Mixtures of Fe2O3 and Fe 3 O 4 can be distinguished for temperatures up to 600 °C using 532 nm; Copper oxides did not yield suitable signals at elevated temperatures; The custom NETL samples did not yield suitable signals at elevated temperatures. Raman spectroscopy would be a suitable approach for calcium sulfate as this material provides a very strong Raman signal at high temperatures. Oxygen carrier particles of higher interest such as metal oxides, however, do not yield a strong-enough signal at elevated temperatures. As such, Raman spectroscopy is not suitable to differentiate the oxidation state of these materials at temperatures above 600 °C.

01 COAL, LIGNITE, AND PEAT↗

Chemical Looping Coal Gasification Sub-Pilot Unit Demonstration and Economic Assessment for IGCC applications (Final Report)

The Ohio State University (OSU) coal to syngas (CTS) technology is an advanced air separation process that can be applied for electricity production via an integrated gasification combined cycle (IGCC). The objective of the proposed project is to enable the OSU CLG technology for a commercially relevant demonstration by 2020. In order to accomplish this objective, small pilot scale demonstration of the CLG reactor system was performed. The small pilot test unit incorporates commercially scalable non-mechanical gas sealing and solids flow control components for extended operations of the integrated reactor system. A cumulative demonstration of greater than 100 hours was performed to confirm the reliability of the reactors (reducer and oxidizer) and non-mechanical devices in maintaining controlled solid circulation, gas sealing, and coal distribution in the reactor (reducer) as well as to confirm sustained syngas product performance. A comprehensive techno-economic analysis (TEA) of the OSU CLG process for IGCC application was conducted with the support of WorleyParsons, Ltd. (WP) and compared to the Department of Energy (DOE) baseline IGCC report. Using the data gained from the small pilot demonstration, a complete comprehensive techno-economic analysis (TEA) of the CLG process was conducted. The evaluation was used as basis to attract utilities and coal industries in Ohio. The project duration lasts 30 months (6 months of no cost extension). Ohio coal was used in the integrated CLG small pilot unit to convert to high hydrogen syngas. A demonstration of the integrated chemical looping reactor system at the 15 kW th scale accelerates technology commercialization in the near term. The 15 kWth demonstration addressed several major technology gaps, such as coal injection and distribution in the reducer, controllable solids circulation with the desired fuel to solids ratio, system pressure distribution for proper gas sealing, effects of contaminants and fuel/oxygen carrier residence time requirements. The fates of impurities, such as SO x and NO x was also investigated in unit demonstrations. WP conducted a comprehensive system TEA to optimize the OSU CLG process design for efficient electricity generation with greater than 90% CO 2 capture in IGCC applications. The conclusion of this project supports the further scale-up of the technology to a commercially applicable large pilot scale test unit for operation by 2020. More importantly, it benefits Ohio as it provides an economically competitive mean for power generation with carbon capture. Given the rise of natural gas usage and strict environmental regulations, the use of Ohio coal is expected to decrease and thus impact the coal economy in Ohio. The conclusion of this project provided way for Ohio coal to compete in the future and secure jobs in the energy sector.

01 COAL, LIGNITE, AND PEAT↗